Loading...
CORRESPONDENCE CAULFIELD & WHEELER, INC. Land Surveyors. Consulting Engineers January 25, 1988 Mr. Carmen S. Annunziato City of Boynton Beach Planning Dept. 200 North Seacrest Blvd. Boynton Beach, Fla. 33425 Subject: Proposed Parking Lot Addition Motorola Plant Site Boynton Beach, Fla. Dear Mr. Annunziato: Please find attached for your review and approval six copies of the following information: 1. Overall site plan illustrating the total site with the proposed parking lot addition. 2. Paving and drainage plans for the proposed parking lot addition. 3. Paving and drainage details for the parking lot addition. 4. The landscape and lighting plan for the proposed parking lot addition. The proposed parking previously approved overall This submittal is for review parking lot addition as shown lot addition was a portion of the master site plan for the Motorola Site. and approval of just that portion of the on the attached plans. If questions us. you require any additional information, or if you have any concerning our submittal, please do not hesitate to contact Sincerely, CAULFIELD & tu '--' C. Danvers Beatty Project Engineer CDB:rms Encl. cc: Joe Sperlazza, Motorola, Inc. Carl Bice, Hardrives, Inc. 7301 A West Po I metto Pork Road. Su ite 1 OOA Boca Raton, IFlorida 33433 305.392-1991 ............ .: CAULFIELD & WHEELER, INC. land Surveyors. Consulting Engineers Mr. Tom Clark City Engineer City of Boynton Beach 200 No. Seacrest Blvd.P.O. Box 310 Boynton Beach, Fla. 33425 Subject: Motorola Parking Lot Addition Motorola Plant Boynton Beach, Fla. Dear Mr. Clark: In a meeting on January 4, 1988 with Mr. Bill Flushing of the City of Boynton Beach Engineering Dept. we were advised to submit to you one copy of civil engineering plans for the proposed parking lot addition for your preliminary review. The attached plans illustrate how the proposed parking lot addition will connect to existing parking at the Motorola plant site. Drainage will be provided by constructing two inlets - one inlet at either end of the parking lot addition and connecting via drainage pipes to existing inlets within the existing parking area. Also please find attached a copy of the South Florida Water Management District permit for the Motorola plant site. According to the permit, the parking lot addition is included in the overall drainage scheme and drainage capacity for this parking area has already been provided for in the overall lake system. We are aware that the proposed plan is not in conformance with the latest parking lot criteria for the City of Boynton Beach, however, there is currently 1150 parking stalls at the Motorola site; and we would like the additional 250 parking stalls to conform with the existing parking scheme that is currently in service. We would also like to begin the process for obtaining variances that may be required so as that we may conform to the existing parking. 7301 A West Palmetto Park Road. Suite 100A Boca Raton, Florida 33433 305.392-1991 ., Page 2 - January 6, 1988 Mr. Torn Clark, City Engineer City of Boynton Beach Subject: Motorola Parking Lot Addition Motorola Plant Boynton Beach, Fla. Your prompt review of our plans will be greatly appreciated. If we can provide you with any additional information, or if you have any questions, please do not hesitate to contact us. Sincerely, ;PJ2 & C. Danvers Beatt Project Engineer CDB:rms