REVIEW COMMENTS DEPA fMENT OF DEVELOPMEr ENGINF;~ (j'fL 100 Bast Boynton Beach Blvd. P. O. Box 310 Boynton Beach, Florida 33425-0310 June 24, 1996 ""II~" ,111 '\'I1l1 :17 rn :'~H\#i/ 'I?, n ': .,.;.~ - ';;:i 1 U JUN ') 5 1900 CCL Consultants, Inc. 2355 Salzedo Street Suite 202 Coral Gables, Florida 33134 Attention: Louis R. Campanile ~~-PUD ~;~:!.~~Ii~~~~ Dear Mr. Campanile: Staff has reviewed subject plat and has the following comments and recommendations: Utility Department 1. Show easement for proposed force main re-route, (Chapter 6, Art.IV, Sec.6A. pg.6-9). 2. Show easement for proposed gravity sewer main to Tract C Woolbright Place Plat I, (Chapter 6, Art.IV, Sec.6A, pg.6-9). Police Department -No Comments Fire Department - No Comments Planning and Zoning Department 1. Show on the plat, the existing 2.5 foot wide FP&L easement located along the north perimeter of the PUD. (Chap.5, Art.V, Sec.1D7, pg.5-6) 2. Show, dimension and identify on the plat, the 10 foot wide required buffer along the north interior PUD property line of the project. The 10 foot wide buffer shall not overlap any other type of easements. (Master Plan revised 3/2/95) 3. Show, dimension and identify on the plat. the 25 foot wide required buffer along the north property line of the PUD. The 25 foot wide buffer shall not overlap any other type of easement. (Master Plan revised 3/2/95) Recreation and Parks Department - No Comments Public Works Department - No Comments Development Department, Building Division - No Comments Phone: (407) 375-6280 FAX: (401) 375-6357 CCL Consultants, Inc. Re: Vinings PUD - Plat II Review June 24, 1996 Page #2 Development Department, Engineering Division Comments: 1. All plans submitted for specific permits shall meet the City's code requirements at time of application. These permits include, but are not limited to the following; site lighting, paving, drainage, curbing, landscaping, irrigation and traffic control devices. Permits required from agencies such as the FDOT, PBC, SFWMD and any other permitting agency shall be included with your permit request. 2. Revise documents to reflect all comments. 3. Provide parking facility for recreation area including HlC stall. Chap.2, Sec.lIHI6e(l2), pg.2-I08 4. Submit balance of fees. Chap.5, Art.V, Sec. lA, pg.5-4 5. Sign Certificate of Title. Chap.5, Art.V, Sec.lD6f, pg.5-6 6. Provide corporate seal. Chap.5, Art.V, Sec.lD6f, pg.5-6 7. Submit restrictive covenants, or state on the plat that none exist. Chap.5, Art. V, Sec.lDII, pg.5-7 8. Submit proper surety. Chap.5, Art.V, Sec.2A2, pg.5-8 9. Submit ownership and maintenance association documents. Chap.5, Art.V, Sec.2A4, pg.5-9 10. Provide Certification by Developer's Engineer that drainage plan complies with all City codes & standards. Chap.6, Art.IV, Sec.5A, pg.6-7 and Chap.23, Art.IIF, pg.23-8 11. Inlets must be in grassy areas unless otherwise approved. Chap.6, Art.IV, Sec.5B, pg.6-8 and Chap.23, Art.IIF, pg.23-8 12. Provide detail showing grate elevation 6" above surrounding grassed areas to require percolation prior to conveyance to on site water bodies. Chap.6, Art.IV, Sec.5B, pg.6-8 13. Submit engineer's signed and sealed estimate of cost. Chap.6, Art.V, SecAB4, pg.6-20 14. Applicant's attention is directed to Chap.7, pg.7-1 regarding surety requirements. IS. All landscaped areas shall be provided with an automatic water supply system. Chap.7.5, Art.II, Sec.5B, pg.7.5-14 16. Parking lot dimensions, striping, aisles, stalls, radii, signs, landscaping, etc. must conform with City codes and standards. Chap.23, Art.II, pg.23-6 17. Provide a satisfactory lighting plan. Chap.23, Art.IIA, pg.23-6 18. Photometrics must be approved for both pedestrian and parking lot lighting before permit can be issued. Chap.23, Art.IIAla, pg.23-6 19. Certify that light poles are in compliance with Standard Building Code and withstand a 110 mph wind load. Chap.23, Art.IIAla, pg.23-6 20. Provide stop signs and stop bars in accordance with the "Manual on Uniform Traffic Control Devices". Chap.23, Art.IIB2, pg.23-7 CCL Consultants, Inc. Re: Vinings PUD - Plat II Review June 24, 1996 Page #3 21. Landscaped areas in parking lots must be protected by wheel stops or curbs. Chap.23, Art.IIE, pg.23-7. Show wheel stops in "Typical Pavement Section" and "Typical Parking Lot Section", sheet 6 of 8. 22. All parking lots shall meet or exceed State Handicap Code requirements and comply with the Standard Building Code and the Countywide amendments thereto. Chap.23, Art.I1K, pg.23-9 23. Remove reference to drainage easements in Note 1. 24. Specify 18" depth of Type "D" curb rather than 12", sheet 5 of 8. FDOT Index 300. 25. Change Note 8 on Sheet 2 of2 to reference the City's Land Development Regulations, instead of "Appendix C, Subdivision and Platting Regulations". Recommendations: A. Recommend advance "Pedestrian Crosswalk" markings and signage at crosswalk locations. B. Provide at least one HlC parking space at visitor parking location just north of main entrance. Please notify us in writing when you have satisfied these comments and recommendations so that the Development Order can be drafted for consideration by the City Commission. Very truly yours, CITY OF BOYNTON BEACH, FLORIDA c:2/~?/2f~ William Hukill, P .E. City Engineer WVH/ck xc: Carrie Parker, City Manager John Guidry, Utilities Director Marshall Gage, Police Chief Floyd Jordan, Fire Chief Tambri Heyden, Planning & Zoning Director Charlie Frederick, Recreation & Parks Director Al Newbold, Deputy Director of Development Bettina Scherer, Trammell Crow Residential C;VINIIREV PLANNING AND ZONING DEPARTMENT MEMORANDUM NO. 96-322 FROM: William Hukill City EngineerT/IJ, Tambri J. Heyden ['~tl-7j}'W - Planning and zOnit;. ir ct~ Michael E. Haag . Current Planning Coordinator TO: THRU: DATE: June 20, 1996 SUBJECT: Vinings Phase II, PUD - plat review comments File No. PRPL 96-001 Please be advised of the following comments regarding the first review of the above-referenced request: 1. Show on the plat, the existing 2.5 foot wide FP&L easement located along the north perimeter of the PUD. 2. Show, dimension and identify on the plat, the 10 foot wide required buffer along the north interior PUD property line of the project. The 10 foot wide buffer shall not overlap any other type of easements. 3. Show, dimension and identify on the plat, the 25 foot wide required buffer along the north property line of the PUD. The 25 foot wide buffer shall not overlap any other type of easement. MEH:bme a: lSTVINII . PLT ~'88 ill PLANNING AND ZONING DEPT. LAKE WORTH DRAINAGE DISTRICT / June 17, 1996 13081 MILITARY TRAIL DELRAY BEACH. FLORIDA 33484 Tambri J. Heyden, Director City of Boynton Beach Planning and Zoning Department P.O. Box 310 Boynton Beach, FL 33425-0310 Dear Ms. Heyden: Subject: Technical Review Committee Agenda The Lake Worth Drainage District offers the following comments regarding the items on the June 11, 1996 meeting agenda: 1. Flowers WarehouselDistribution Center - No objection 2. Riverwalk Shopping Center - Is not located within the L wnD Service Area. 3. Vinings Phase II - No objection. A drainage permit has been issue for this project. Please be advised that a drainage review will be needed prior to any construction which may alter the current drainage patterns of any project in the L WDD. 'lie appre~iate being gi'/e~ the opp~rt!!i"'lit:/ tc ~DIT''u'~errt en the abo'le. Sincerely, P AM/SJW/mtb c: Shaughn J. Webb, ChiefInspector, L WDD Delray Beach & Boca Raton 498-5363 . BoynlDn Beach & West Palm Beach 737-3835 . FAX (407) 495-9694 ENGINEERING MEMO #96- rD) ~ @ ~..n uU , ~I MAY 28 1996 ~ DATE: May 24,1996 PLANNiNG AND ONING DEPI . 'J/ ~f. ~~ . 'fp- ~ ~~h) TO: BILL CAVANAUGH, FIRE PREVo OFF. ROBERT EICHORST, P.W. DIR. SGT. MARLON HARRIS, P.D. T AMBRI HEYDEN, PLAN. & ZONING DIR. SKIP MILOR, UTIL. CHIEF FIELD INSP. AL NEWBOLD, DEPUTY BLDG. OFF. JOHN WILDNER, PARKS SUPER. & KEVIN HALLIHAN, FORESTER FROM: KEN HALL, ENG. PLANS CHECKlINSPECTOR 375-628~ SUBJECT: T.R.C. REVIEW - THE VININGS - PHASE 2. PLEASE REVIEW THE A TT ACHED PLAT AND REQUIRED IMPROVEMENTS FOR CODE SUFFICIENCY AND PROVIDE YOUR COMMENTS TO THE ENGINEERING DIVISION BY THE END OF JUNE 14, 1996. ALSO ATTACHED IS A COPY OF THE APPROVED MASTER PLAN FOR REFERENCE. IF YOU HAVE NO COMM:ENTS, PLEASE SIGN OFF ON THE STAMPED SET IN THE ENGINEERING DEPARTMENT. THE REFERENCED PLANS SHOULD BE KEPT FOR ANY FUTURE REFERENCE YOU MAY HAVE. PLEASE CALL US IF YOU HAVE ANY QUESTIONS. THANKS! KRH/krh C: William Hukill, Dev. Dir. and to file Vinplat.two