REVIEW COMMENTS
DEPA fMENT OF DEVELOPMEr
ENGINF;~
(j'fL
100 Bast Boynton Beach Blvd.
P. O. Box 310
Boynton Beach, Florida 33425-0310
June 24, 1996
""II~" ,111 '\'I1l1 :17 rn
:'~H\#i/ 'I?, n
': .,.;.~ - ';;:i 1 U
JUN ') 5 1900
CCL Consultants, Inc.
2355 Salzedo Street
Suite 202
Coral Gables, Florida 33134
Attention: Louis R. Campanile
~~-PUD ~;~:!.~~Ii~~~~
Dear Mr. Campanile:
Staff has reviewed subject plat and has the following comments and recommendations:
Utility Department
1. Show easement for proposed force main re-route, (Chapter 6, Art.IV, Sec.6A.
pg.6-9).
2. Show easement for proposed gravity sewer main to Tract C Woolbright Place Plat
I, (Chapter 6, Art.IV, Sec.6A, pg.6-9).
Police Department -No Comments
Fire Department - No Comments
Planning and Zoning Department
1. Show on the plat, the existing 2.5 foot wide FP&L easement located along the
north perimeter of the PUD. (Chap.5, Art.V, Sec.1D7, pg.5-6)
2. Show, dimension and identify on the plat, the 10 foot wide required buffer along
the north interior PUD property line of the project. The 10 foot wide buffer shall
not overlap any other type of easements. (Master Plan revised 3/2/95)
3. Show, dimension and identify on the plat. the 25 foot wide required buffer along
the north property line of the PUD. The 25 foot wide buffer shall not overlap any
other type of easement. (Master Plan revised 3/2/95)
Recreation and Parks Department - No Comments
Public Works Department - No Comments
Development Department, Building Division - No Comments
Phone: (407) 375-6280
FAX: (401) 375-6357
CCL Consultants, Inc.
Re: Vinings PUD - Plat II Review
June 24, 1996
Page #2
Development Department, Engineering Division
Comments:
1. All plans submitted for specific permits shall meet the City's code requirements at
time of application. These permits include, but are not limited to the following;
site lighting, paving, drainage, curbing, landscaping, irrigation and traffic control
devices. Permits required from agencies such as the FDOT, PBC, SFWMD and
any other permitting agency shall be included with your permit request.
2. Revise documents to reflect all comments.
3. Provide parking facility for recreation area including HlC stall. Chap.2,
Sec.lIHI6e(l2), pg.2-I08
4. Submit balance of fees. Chap.5, Art.V, Sec. lA, pg.5-4
5. Sign Certificate of Title. Chap.5, Art.V, Sec.lD6f, pg.5-6
6. Provide corporate seal. Chap.5, Art.V, Sec.lD6f, pg.5-6
7. Submit restrictive covenants, or state on the plat that none exist. Chap.5, Art. V,
Sec.lDII, pg.5-7
8. Submit proper surety. Chap.5, Art.V, Sec.2A2, pg.5-8
9. Submit ownership and maintenance association documents. Chap.5, Art.V,
Sec.2A4, pg.5-9
10. Provide Certification by Developer's Engineer that drainage plan complies with all
City codes & standards. Chap.6, Art.IV, Sec.5A, pg.6-7 and Chap.23, Art.IIF,
pg.23-8
11. Inlets must be in grassy areas unless otherwise approved. Chap.6, Art.IV, Sec.5B,
pg.6-8 and Chap.23, Art.IIF, pg.23-8
12. Provide detail showing grate elevation 6" above surrounding grassed areas to
require percolation prior to conveyance to on site water bodies. Chap.6, Art.IV,
Sec.5B, pg.6-8
13. Submit engineer's signed and sealed estimate of cost. Chap.6, Art.V, SecAB4,
pg.6-20
14. Applicant's attention is directed to Chap.7, pg.7-1 regarding surety requirements.
IS. All landscaped areas shall be provided with an automatic water supply system.
Chap.7.5, Art.II, Sec.5B, pg.7.5-14
16. Parking lot dimensions, striping, aisles, stalls, radii, signs, landscaping, etc. must
conform with City codes and standards. Chap.23, Art.II, pg.23-6
17. Provide a satisfactory lighting plan. Chap.23, Art.IIA, pg.23-6
18. Photometrics must be approved for both pedestrian and parking lot lighting before
permit can be issued. Chap.23, Art.IIAla, pg.23-6
19. Certify that light poles are in compliance with Standard Building Code and
withstand a 110 mph wind load. Chap.23, Art.IIAla, pg.23-6
20. Provide stop signs and stop bars in accordance with the "Manual on Uniform
Traffic Control Devices". Chap.23, Art.IIB2, pg.23-7
CCL Consultants, Inc.
Re: Vinings PUD - Plat II Review
June 24, 1996
Page #3
21. Landscaped areas in parking lots must be protected by wheel stops or curbs.
Chap.23, Art.IIE, pg.23-7. Show wheel stops in "Typical Pavement Section" and
"Typical Parking Lot Section", sheet 6 of 8.
22. All parking lots shall meet or exceed State Handicap Code requirements and
comply with the Standard Building Code and the Countywide amendments thereto.
Chap.23, Art.I1K, pg.23-9
23. Remove reference to drainage easements in Note 1.
24. Specify 18" depth of Type "D" curb rather than 12", sheet 5 of 8. FDOT Index
300.
25. Change Note 8 on Sheet 2 of2 to reference the City's Land Development
Regulations, instead of "Appendix C, Subdivision and Platting Regulations".
Recommendations:
A. Recommend advance "Pedestrian Crosswalk" markings and signage at crosswalk
locations.
B. Provide at least one HlC parking space at visitor parking location just north of
main entrance.
Please notify us in writing when you have satisfied these comments and recommendations so that
the Development Order can be drafted for consideration by the City Commission.
Very truly yours,
CITY OF BOYNTON BEACH, FLORIDA
c:2/~?/2f~
William Hukill, P .E.
City Engineer
WVH/ck
xc: Carrie Parker, City Manager
John Guidry, Utilities Director
Marshall Gage, Police Chief
Floyd Jordan, Fire Chief
Tambri Heyden, Planning & Zoning Director
Charlie Frederick, Recreation & Parks Director
Al Newbold, Deputy Director of Development
Bettina Scherer, Trammell Crow Residential
C;VINIIREV
PLANNING AND ZONING DEPARTMENT
MEMORANDUM NO. 96-322
FROM:
William Hukill
City EngineerT/IJ,
Tambri J. Heyden ['~tl-7j}'W -
Planning and zOnit;. ir ct~
Michael E. Haag .
Current Planning Coordinator
TO:
THRU:
DATE:
June 20, 1996
SUBJECT: Vinings Phase II, PUD - plat review comments
File No. PRPL 96-001
Please be advised of the following comments regarding the first
review of the above-referenced request:
1. Show on the plat, the existing 2.5 foot wide FP&L easement
located along the north perimeter of the PUD.
2. Show, dimension and identify on the plat, the 10 foot wide
required buffer along the north interior PUD property line of
the project. The 10 foot wide buffer shall not overlap any
other type of easements.
3. Show, dimension and identify on the plat, the 25 foot wide
required buffer along the north property line of the PUD. The
25 foot wide buffer shall not overlap any other type of
easement.
MEH:bme
a: lSTVINII . PLT
~'88
ill
PLANNING AND
ZONING DEPT.
LAKE WORTH DRAINAGE DISTRICT
/
June 17, 1996
13081 MILITARY TRAIL
DELRAY BEACH. FLORIDA 33484
Tambri J. Heyden, Director
City of Boynton Beach
Planning and Zoning Department
P.O. Box 310
Boynton Beach, FL 33425-0310
Dear Ms. Heyden:
Subject:
Technical Review Committee Agenda
The Lake Worth Drainage District offers the following comments regarding the items on
the June 11, 1996 meeting agenda:
1. Flowers WarehouselDistribution Center - No objection
2. Riverwalk Shopping Center - Is not located within the L wnD Service Area.
3. Vinings Phase II - No objection. A drainage permit has been issue for this project.
Please be advised that a drainage review will be needed prior to any construction which
may alter the current drainage patterns of any project in the L WDD.
'lie appre~iate being gi'/e~ the opp~rt!!i"'lit:/ tc ~DIT''u'~errt en the abo'le.
Sincerely,
P AM/SJW/mtb
c: Shaughn J. Webb, ChiefInspector, L WDD
Delray Beach & Boca Raton 498-5363 . BoynlDn Beach & West Palm Beach 737-3835 . FAX (407) 495-9694
ENGINEERING MEMO #96-
rD) ~ @ ~..n
uU
, ~I
MAY 28 1996 ~
DATE: May 24,1996
PLANNiNG AND
ONING DEPI
. 'J/ ~f.
~~ . 'fp-
~ ~~h)
TO: BILL CAVANAUGH, FIRE PREVo OFF.
ROBERT EICHORST, P.W. DIR.
SGT. MARLON HARRIS, P.D.
T AMBRI HEYDEN, PLAN. & ZONING DIR.
SKIP MILOR, UTIL. CHIEF FIELD INSP.
AL NEWBOLD, DEPUTY BLDG. OFF.
JOHN WILDNER, PARKS SUPER. & KEVIN HALLIHAN, FORESTER
FROM: KEN HALL, ENG. PLANS CHECKlINSPECTOR 375-628~
SUBJECT: T.R.C. REVIEW - THE VININGS - PHASE 2.
PLEASE REVIEW THE A TT ACHED PLAT AND REQUIRED IMPROVEMENTS FOR
CODE SUFFICIENCY AND PROVIDE YOUR COMMENTS TO THE ENGINEERING
DIVISION BY THE END OF JUNE 14, 1996. ALSO ATTACHED IS A COPY OF THE
APPROVED MASTER PLAN FOR REFERENCE.
IF YOU HAVE NO COMM:ENTS, PLEASE SIGN OFF ON THE STAMPED SET IN THE
ENGINEERING DEPARTMENT. THE REFERENCED PLANS SHOULD BE KEPT FOR
ANY FUTURE REFERENCE YOU MAY HAVE. PLEASE CALL US IF YOU HAVE ANY
QUESTIONS. THANKS!
KRH/krh
C: William Hukill, Dev. Dir. and to file
Vinplat.two