Loading...
LEGAL APPROVAL LEGALI APPROVAL DOCUMENTS CITY of BOYNTON BEACH ~ ~ 100 E. Boynton Beach Blvd. P. O. Box 310 Boynton Beach, Florida 33435-0310 (407) 734.8111 OFFICE OF THE PLANNING DIRECTOR November 22, 1989 Stanley Consultants of Florida, Inc. Attn: Mr. David Flinchum, ASLA 2000 Lombard St West Palm Beach, Fl 33407 RE: Shoppes of Woolbright (Home Depot) Master Plan Modification - File No. 364 Dear Mr. Flinchum: Please be advised that on Tuesday, November 21, 1989, the City Commission approved the referenced master plan modification as submitted. If you have any questions concerning this matter, please do not hesitate to contact me. Very truly yours, ~__BOYNTON B~~CH. :;?~/ Ut~~ TIMOTHY P. CANNON Interim Planning Director TPC:frb cc: Interim City Manager Technical Review Board Central File Frank Lamia, Greenberg Farrow Architecture, Inc Shoppes CITY of BOYNTON BEACH ,. Q 100 E. Boynton Beach Blvd. P O. Box 310 Boynton Beach, Florida 33435-0310 (407) 734.8111 OFFICE OF THE PLANNING DIRECTOR November 22, 1989 stanley consultants of Florida, Inc. Attn: Mr. David Flinchum, ASLA 2000 Lombard street West Palm Beach, Fl 33407 RE: Shoppes of woolbright (Home Depot) - site Plan - File No. 363 Dear Mr. Flinchum: Please be advised that on Tuesday, November 21, 1989, the City Commission approved the referenced site plan, subject to staff comments, copies of which are attached. These plans were approved subj ect to your compliance attached stipulations. After you have amended your ref lect these stipulations, please submit two copies plan drawings with the changes incorporated to the Department for permitting purposes. with the plans tq of final Building The approval of the City entitles you to construct only the improvements shown on the site plan. The site plan will be viewed procedurallY as an as-built or record drawing. If you have any questions concerning this matter, please do not hesitate to contact me. Very truly yours, CITY OF BOYNTON BEACH ~.~~ TIMOTHY P. CANNON Interim planning Director TPC:frb Encs cc: Interim City Manager Technical Review Board central File Frank Lamia, Greenberg Farrow Architecture, Inc HDepotSP MEMORANDUM November 8, 1989 TO: Timothy P. Cannon, Interim planning Director FROM: Michael E. Haag, DevelopmenT compliance Administrator RE: SITE PLAN ).OR HOME DEPOT Upon review of th' above-mentioned project, the following comments must be ~,ddressed in order to conform with Boynton Beach City Codes: 1. south Florida Water Management District permit is required. 2. Lake worth Drainage District Permit is required. In order to facilitate the permitting process, the following information should be included within your documents submitted to the Building Department for required permits: I. All platting procedures identified in Appendix C, Subdivision and platting Regulations and the requirements stated in Chapter 19, Articles II and III of the Boynton Beach Code of Ordinances must be met in every respect. 2. All signage must comply with the Boynton Beach Sign Ordinance. 3. The entire site must be enclosed with a peripheral green belt with a minimum width of ten (10) feet. Except where the planned commercial district abuts a residential district, the peripheral green belt width is twenty-five (25) feet and a buffer wall is required. The peripheral green belt may be considered as common area and contain the free-standing sign identifying the planned commercial district. MEH:ld ~~ /Ii} t~V ;:- Michael E. Haag ,9 xc: Don Jaeger HOMEDEPO.DOC Grayarc. ....0. ,0)( 29<< Hartlord, cr 06104.2944 CALL TOLL FllEE. 1.600-243-5250 REPLY MESSAGE Fold At (tl To Fa Grayarc WIndow Envelope" EW10P REORDER ITEM' F289 - FROM W. D. Cavanaugh Fire Department r -, TO City Planner SUBJECT TRB Comments on Home Depot , ____.DATE. _~~L~3L~_9__________ ,.OL.D + A meeting was held prior to TRB with the appropriate representatives. No further comments ~re in order. PLEASE REPLY TO 4/i)fJuc, "~~ ~ SIGNED w. D. Cavanaugh, Fire Dept. TRB Rep. . REPLY DATE ,)IGNED \tern II F26'-< Gra.yarc, P.O. Box 2944. Han1ord, CT 061()1\-2" @ Wt1eeler Group, Inc. 1982 \-\ i ~; t ()l:. ,~ A' c- >.J ~ f- \IS, ,N ADDIICC; tL 11ET' IfiN THI lPY TO lOEi< Ji ,~ .!', I " . ,,," MEMORANDUM November 8. 1989 TO: Jim Golden Senior City PLmner VIA: Ann 'l'oney Acting Engineering Administrator FRCM: Roger Kuver Acting Assistant to the City Engineer RE: 'IRE Corrrrents Horre Depot l) APpendix A - Zoning Section 6 _ 12 Platting, Site DeveloptEnt plans and Building Permits. a) Platting. All planned commercial developments are subject to and shall be devel,ped consistent with the requirements of Appendix C, Subdivision and Platting Regulations of the Boynton Beach Code of Ordinances b) Site developrrelt plans All plans for lots or parcels proposed to be developed " thin planned commercial developments are subject to and shall be dc'veloped consistent with the requirements of Chapter 19, Article II Site Plan Review and APproval and Chapter 19, Article III, Corrrnuni ty '\ppearance Board of the Boynton Beach Code of Ordinances c) Pennits No t 111ding permits shall be issued unless and until platting procedures and the requirements outlined in Chapter 19, Articles II and III of the Cit Code are completed in every respect. 2) submit a drainage plan consistent with AppendiX C - subdivisions, Platting Article X - Desier, RequirelTl2nts Section 5 a) Drai ,age b) Storiiwater Treatment Section 6 a) Utility Easerrents b) Drai ,age Easements 3) Construction Detail Section "A-A" on paving and drainage plan incorrectly depicts 6' extrudeD concrete curbing. Revise to Type "D" of the sarre sheet 4) Section "A-A" calls for catch basin grate elevation which matches edge of pavement elevatiutl. Revise plans to indicate an inlet elevation which is lower than edge of pavement. 5) submit a parking lot plan which includes all traffic control devices including pavement markings, signage, etc. Details required. 6) Refer to Fire Department for fire lane requirements. '_C K=& ;{$ RK/ck . . l MEMORANDUM TO: Timothy P. Cannon, Interim Planning Director Kevin J Hallahan, Forester/Horticulturist FROM: Home Depot at Woolbright place - site plan SUBJECT: DATE: November 8, 1989 The applicant must provide a tree inventory/survey for the area and a description of the preservation methods in accordance with Tree preservation Jrdinance No. 81-21. * () , / i!,., L~/l KeY' ~'''; HainahA'* - - - Forester/Horticu111lrist Recreation & Park 'epartment KJH:pb A:HOMEDEPO.DOC . . MEMORANDUM . l-----"/ Nc 'ember 7, 1989 . TO: Chairman and Members, planning and Zoning Board T' Timothy P. Cannon, Interim Planning Director L- THRU: FROM: James J. Golden, senior City Planner RE: Home Depot at Shoppes of Woolbright - site Plan File No. 363 with respect to the above, please be advised of the following: 1. platting is required prior to the issuance of building permits (Sections 6.F.12.a and c of Appendix A, Zoning) . 2. At least two driveway connections should be provided between the Home Depot parking lot and the outparcel site to provide the necessary access to the outparcel site in connection with the approved master plan. These connections should be designed so that they align with the proposed location of the access aisles within the Home Depot parking lot and should be the same width (27 feet). 3. Cross access and parking easements should be dedicated between the Home Depot site, the outparcels and the main shopping center. Dedication of said easements can be done in connection with plat approval. In areas where cross access is provided, perimeter landscaping is not required. 4. There are two light pole fixtures that encroach parking spaces. These poles should be relocated to landscaped islands so as not to reduce the minimum size of the parking stalls as set forth in Article X, Parking Lots, of the Code of Ordinances. . 5. The proposed roof top satellite dish must meet the requirements of Section 4.M of Appendix A, Zoning. . 6. The drainage system for the truck well must be designed to meet the requirements of Section 4.N.ll.c of Appendix A, Zoning. )--1. ~ ,:lAMES ~. GOLDEN JJG:frb cc: City Attorney Homdepot MEMORANDUM .-------------...." ..---.------.-.---- DATE November 8, 1989 ,'0 Tim Cannon Act ing Pi "1\ ROM John A Gu o ire c t. or ,., ing Din'ctor ;~:,""o\~ SUBJ TRB Review Home Depot - Site Plan ~e can approve th project, subject to the following conditions 1 The sanitarj ductilE~ iron Provide prof elevations ewer main shall be of vitrified clay and n accordance with the City's specifications eS of the sewer indicating rim and invert 2 Add a note tc the effect that this department will maintain the main line sewer only Services are to be privately owned and maintained 3 Show easements for all water and sewer lines, 4 Add a note requiring swabbing of all new water mains We recommend a plugged 10" x 10" tee facing upwards be added at the point of connection 5 A 6" polyethylene-lined DIP force main shall be included from the existing 12" force main to the gravity sewer This and other changes will allow for abandonment of the on-site 12" force main at a future date 6 Reduced pressure backflow preventers will be required on the domestic service and fire line We recommend 2 parallel units on the domestiC service so that service will not be interrupted during testing or maintenance of the units 7, Provide fire-flow calculations to justify the water main sizing dmt bc Peter Mazzella MEMORANDUM TO: Mr. James Golden . FROM: Lt. Dale Hammack EE: Home Depot DATE: November 6 1989 As per our discussions in regards to the Technical Review Board Meeting of Novembe: 7, 1989, I am recommending the following: 1. Pavement markings including stop bars. (City Ord.5-l42C) 2. Stop signs at exit onto S.W. 8th St. (City Ord.5-l42C) 3. Stop signs at ends of parking isles. (City Ord. 5-l42C) 4. comply with security construction ord. (5-86) 5. Lighting on South and East side should be pole-mounted perimeter lighting. (5-138) /l,pdJ ~ L . Dale Hammack DH/cm f_C' .,. "f~l'" I ~, '-. tL\t. ... I' T ~ . ,-...- - _.-