LEGAL APPROVAL
CITY of
BOYNTON BEACH
i
. I
100 E. Boynton Beach Blvd.
P. O. Box 310
Boynton Beach, Florida 33425.0310
(407) 734.8111
OF THE PLANNING DIRECTOR
June 22, 1989
Miller Meier Kenyon Cooper
Architects & Engineers, Inc
Attn: craig W. Kenyon
101 Northeast Third Avenue, Suite 300
Fort Lauderdale, FI 33301
RE: Fire Station No. 3 Site Plan - File No ~'3
Dear Mr. Kenyon:
Please be advised that on Tuesday, June 20, 1989, the City
commission approved the referenced site plan subject to staff I
comments, copies of which are attached. I.
These plans were approved subject to your compliance with the
attached stipulations. After you have amended your plans to
reflect these stipulations, please submit two copies of final
plan drawings with the changes incorporated to the Building
I Department for permitting purposes.
The approval of the City entitles you to construct only the
improvements shown on the site plan. The site plan will be
viewed procedurally as an as-built or record drawing. If you I
have any questions concerning this matter, please do not hesitate I
to contact me.
, .,
'.
Very truly yours,
CITY OF BOYNTON BEACH
(2.....
,
, /\ _ ~-.:::r-
~.IlL- ,....------ ~ -.
CARMEN S. ANNUNZIATO, AICP
Planning Dir~ctor
CSA:frb
Encs
cc: City Manager
Technical Review Board
Bill DeBeck
Central File
.'~
.
MEMORANDUM
June 7, 1989
TO:
Chairman and Members
Planning & Zoning Board
FROM:
Carmen S. Annunziato, planning Director
RE:
Fire Station No. 3 - Site Plan - File ~227
with respect to the above, please be advised of the following:
1. Section 5-l42(h)(7) of Article X, parking Lots, permits a
maximum of two (2) driveways on each street frontage. Three
(3) driveways are proposed. A variance is required for a
third driveway. Otherwise, the plans must be amended to
delete one of the three driveways.
2. Lighting details to be provided in accordance with the
standards outlined in Article X, Parking Lots.
~ ~~~
CARMEN S. ANN ZIATO
JJG:frb
~
FSSP~227
.
.' .
MEMORANDUM
TO: Carmen Annunziato
Planning Director
FROM: Kevin J. Hallahan
Forester/Horticulturist
DATE: June 7, 1989
RE: Fire station ~3 - site Plan
1. 50% of the tree species and quantities should be native.
2. 30% of the shrubs, ground covers, species/quantities should
be native. I
3. The applicant should review how existing overhead power
lines will affect the future pruning of proposed trees.
~~ ~ fi:<tYY-' tA.
K~ in J. alla an
Forester/Horticulturist
KJH:ad
DOC: A: FIRESTA
-.
" .
.
MEMORANDUM
. ,
,
TO
Carmen Annunziato, Director
Planning Department
on. June 7, 1989
"t,.~
F.OM
Med Kopczynski, Deputy
Building Official
SU.JaCT
SITE PLAN -
BOYNTON FIRE STATION
Upon preliminary review of the above-reference site plan, the following items
should be addressed by the design professional:
1. Palm Beach County Health Department approval is required.
2. Turnout Permit required from Palm Beach County.
3. All plans submitted for. public record must be sealed by a professional architect 01
engineer.
4. Survey needs to be sealed.
5. Handicap ramp needed to provide access from handicap spaces to fire station.
6. Need details of dumpster to determine compliance.
7. Standards must be designed to withstand 120 m.p.h. windload, also complete
details must be provided.
8. Show type of construction and occupancy type on plan.
;1/
Med Kopczynski
Deputy Building Official
MK:ld
cc: Don Jaeger
.. ~. '\.4
..
.
MEMORANDUM
June 7, 1989
TO: Jim Golden
Senior Planner
VIA: George Hunt
Acting City Engineer
FROM: Roger Kuver
Engineering Department
SUBJECT: Fire Station - North Congress Avenue
1. Revise driveway radii to minimum of 25' on the two eastern most ingress/
egress drives on Miner Road. Article X, 5-142,(H),(2)
2. Handicap striping detail incorrect. Revise to indicate blue striping for
handicap parking, white striping for standard parking. Article X, 5-141(N)
3. Egress only drive needs a stop sign. Article X, 5-142(C)
4. Revise plans to indicate 6" deep sidewalks in driveway areas. (No steel
or wire mesh) as per standard drawing A-80033, Article X, 5-141(N)
5. Obtain permits for construction in Miner Road R.O.W. from appropriate
authorities. Article X, 5-142(H)(6)
6. Submit a Parking Lot lighting plan consistant with Article X, 5-142(A),
5-141(N), Chapter 19, Article II, 19-17(G).
7. Provide a construction detail for all R-l-l stop signs. Detail to include
grouting signs in place. Article X, 5-142(C) , 5-141(N)
8. Revise driveway approaches to eliminate swaled drives, per standard
drawing A-80033, Article X, 5-141(N)
,o,,,&~
Engineering Department
.
RK/ ck
," ...,
,
!
....
MEMORANDUM
Date:
Carmen Annunziato, Planning Directo~ 1
John A. Guidry, Director of Utilities tI~~
June 12, 1989 /'"
To:
From:
Subject:
TRB Review - Fire Station #3 - Site Plan
We can approve this project, subject to the following conditions:
1. Add a second gat.e valve at the easternmost fire hydrant.
2. Add an in-line gate valve just west of the water service to
the fire station. .
3. The water service to the shooting range is proposed under
pavement at one end and should, therefore, be made of "K"
copper. Note that unless the expected water demand is greater
than 50 gpm, a 1" meter will suffice at significant cost
savings.
4. Sanitary services should be connected to the gravity sewer
main via a wye fitting, rather than a direct connection to the
manhole.
5. Delete note no. 25 on page C4. All sewer mains are to be
lamped and televised prior to acceptance by the City.
6. Change the manhole detail to conform to our adopted standards.
,
\I
7. The location of the 16" force main is not las shown. Please
coordinate field locations through this office and depict this I
properly.
dmt
be: Peter Mazzella
\