Loading...
LEGAL APPROVAL CITY of BOYNTON BEACH i . I 100 E. Boynton Beach Blvd. P. O. Box 310 Boynton Beach, Florida 33425.0310 (407) 734.8111 OF THE PLANNING DIRECTOR June 22, 1989 Miller Meier Kenyon Cooper Architects & Engineers, Inc Attn: craig W. Kenyon 101 Northeast Third Avenue, Suite 300 Fort Lauderdale, FI 33301 RE: Fire Station No. 3 Site Plan - File No ~'3 Dear Mr. Kenyon: Please be advised that on Tuesday, June 20, 1989, the City commission approved the referenced site plan subject to staff I comments, copies of which are attached. I. These plans were approved subject to your compliance with the attached stipulations. After you have amended your plans to reflect these stipulations, please submit two copies of final plan drawings with the changes incorporated to the Building I Department for permitting purposes. The approval of the City entitles you to construct only the improvements shown on the site plan. The site plan will be viewed procedurally as an as-built or record drawing. If you I have any questions concerning this matter, please do not hesitate I to contact me. , ., '. Very truly yours, CITY OF BOYNTON BEACH (2..... , , /\ _ ~-.:::r- ~.IlL- ,....------ ~ -. CARMEN S. ANNUNZIATO, AICP Planning Dir~ctor CSA:frb Encs cc: City Manager Technical Review Board Bill DeBeck Central File .'~ . MEMORANDUM June 7, 1989 TO: Chairman and Members Planning & Zoning Board FROM: Carmen S. Annunziato, planning Director RE: Fire Station No. 3 - Site Plan - File ~227 with respect to the above, please be advised of the following: 1. Section 5-l42(h)(7) of Article X, parking Lots, permits a maximum of two (2) driveways on each street frontage. Three (3) driveways are proposed. A variance is required for a third driveway. Otherwise, the plans must be amended to delete one of the three driveways. 2. Lighting details to be provided in accordance with the standards outlined in Article X, Parking Lots. ~ ~~~ CARMEN S. ANN ZIATO JJG:frb ~ FSSP~227 . .' . MEMORANDUM TO: Carmen Annunziato Planning Director FROM: Kevin J. Hallahan Forester/Horticulturist DATE: June 7, 1989 RE: Fire station ~3 - site Plan 1. 50% of the tree species and quantities should be native. 2. 30% of the shrubs, ground covers, species/quantities should be native. I 3. The applicant should review how existing overhead power lines will affect the future pruning of proposed trees. ~~ ~ fi:<tYY-' tA. K~ in J. alla an Forester/Horticulturist KJH:ad DOC: A: FIRESTA -. " . . MEMORANDUM . , , TO Carmen Annunziato, Director Planning Department on. June 7, 1989 "t,.~ F.OM Med Kopczynski, Deputy Building Official SU.JaCT SITE PLAN - BOYNTON FIRE STATION Upon preliminary review of the above-reference site plan, the following items should be addressed by the design professional: 1. Palm Beach County Health Department approval is required. 2. Turnout Permit required from Palm Beach County. 3. All plans submitted for. public record must be sealed by a professional architect 01 engineer. 4. Survey needs to be sealed. 5. Handicap ramp needed to provide access from handicap spaces to fire station. 6. Need details of dumpster to determine compliance. 7. Standards must be designed to withstand 120 m.p.h. windload, also complete details must be provided. 8. Show type of construction and occupancy type on plan. ;1/ Med Kopczynski Deputy Building Official MK:ld cc: Don Jaeger .. ~. '\.4 .. . MEMORANDUM June 7, 1989 TO: Jim Golden Senior Planner VIA: George Hunt Acting City Engineer FROM: Roger Kuver Engineering Department SUBJECT: Fire Station - North Congress Avenue 1. Revise driveway radii to minimum of 25' on the two eastern most ingress/ egress drives on Miner Road. Article X, 5-142,(H),(2) 2. Handicap striping detail incorrect. Revise to indicate blue striping for handicap parking, white striping for standard parking. Article X, 5-141(N) 3. Egress only drive needs a stop sign. Article X, 5-142(C) 4. Revise plans to indicate 6" deep sidewalks in driveway areas. (No steel or wire mesh) as per standard drawing A-80033, Article X, 5-141(N) 5. Obtain permits for construction in Miner Road R.O.W. from appropriate authorities. Article X, 5-142(H)(6) 6. Submit a Parking Lot lighting plan consistant with Article X, 5-142(A), 5-141(N), Chapter 19, Article II, 19-17(G). 7. Provide a construction detail for all R-l-l stop signs. Detail to include grouting signs in place. Article X, 5-142(C) , 5-141(N) 8. Revise driveway approaches to eliminate swaled drives, per standard drawing A-80033, Article X, 5-141(N) ,o,,,&~ Engineering Department . RK/ ck ," ..., , ! .... MEMORANDUM Date: Carmen Annunziato, Planning Directo~ 1 John A. Guidry, Director of Utilities tI~~ June 12, 1989 /'" To: From: Subject: TRB Review - Fire Station #3 - Site Plan We can approve this project, subject to the following conditions: 1. Add a second gat.e valve at the easternmost fire hydrant. 2. Add an in-line gate valve just west of the water service to the fire station. . 3. The water service to the shooting range is proposed under pavement at one end and should, therefore, be made of "K" copper. Note that unless the expected water demand is greater than 50 gpm, a 1" meter will suffice at significant cost savings. 4. Sanitary services should be connected to the gravity sewer main via a wye fitting, rather than a direct connection to the manhole. 5. Delete note no. 25 on page C4. All sewer mains are to be lamped and televised prior to acceptance by the City. 6. Change the manhole detail to conform to our adopted standards. , \I 7. The location of the 16" force main is not las shown. Please coordinate field locations through this office and depict this I properly. dmt be: Peter Mazzella \