IR-1 IRRIGATION PLAN CORLLJ
Z
0
NOTE:
TO
0
Z
EXISTING
-.,-- CONCRETE
MEDIAN
~0£
lJ
.<
EL_
(./3
0
Z
x
50.00'
OE
I
E×ISTIN~ LUELL AT .... I.__ ..........
JEST COFRNEFR OF 51TE
~EBANI~ONED.
..
EXIZ T/NC CIA~IL
PROPERTY LiNE 4' CONCRETE
SIDEWALK --
EASEMENT FOR INGRESS AND EGRESS AS WELL AS WATER cONTROL, DRAINAGE
AND iRRIOATION pURPOSES OVER AND ACROSS THE NORTH 18.82 FEET
(ORB 1840,PAGE 923)
Zone 2
2®.®111/4"
NO
OE
II
I I
-- I I
OE
ON E STORY
RETA L
800 SO, FT.
F,F,E, 15,50
OE
CONTROLLER
55.00'
'EXISTING ASPHALT
RIGHT OF WAY WARRANTY DEED ~
~._ ~_._(~-RB10'5207'RAGEx 10' SIGHT400) ~ ~__
DISTANCE TRIANGLE
BOYNTON BF__ACH BOULEVARD
(STA-I-E ROAD NO, S--804)
CENTERLINE OF 106' RIGHT OF WAY AS sHOWN
ROAD PLAT BOOK 2, PAGES 217 THROUGH 220
EXISTING ·ASPHALT
6C:,4LE:I" =2¢'-¢"
EXISTING CONCRETE
IRRIGATION
.®
®
I
A
10' round or 1G' x !0-3/4' rectangular plastic valve
box marked Irrigation Control Valve". Amtek or Oarson.
Turf: 1. Shrubs: 2.
Epoxy wire connectors UL-UF control wires
PVC Female adaptor ~
and 5ch. 80 nipple
PVC lateral - Angle to
specified depth w/ 451 angle
1/2' Zone valves Rainbird sari, rs
24 Vac or approved eq. ual
PVC Mainline per
plan
Zone Valve Detail
g' Long PVG nipple
-- PVC elbow
PVC Nipple
Mainl!ine Tee
NTS
_, //_. painted flat. black
:"? ..,:,:,:i :'"',}>
Lateral tteter I
~ // ~ a a pipe
Shrub Riser Spray Detail
NTS
· III : I IllJ v~q'lll'l~lll'
LEa, tEND:
MAIN LINE - 1-1/2' connect ~;o ~elt
source
LATERAL ZONE LINES - SDR PVC cs noted
ZONE BOUNDARIES
CONTROLLER - Toro GreenKeeper 8118 Series 4
Station Controtter #GKS18-O4-CAB-D1 Mounted
on side o¢ sCcructure, with ~ Rain Check
aurorae, tiE rain sensor shutoff swit;ch
mounted outside on e(~ve o¢ str'uc~ure,
ZBNE VALVES -
Toro 252 Series,
PROPOSED ~ELL
-Contractor to veri?y
ex,ct tocotion w/owner
PROPOSED PUMP- Ptotec
-?p5192- ~ hp pump
RUST INHIBITOR
SLEEVES -
Sch, 40, 2 Sizes LenDer,
NBTE -. Pipe Size Shown is the Lateral Size, NBT the
6' POP-UP SPRAY -
Tong 570 Series MPR Spe~y Nozzles ~s Requined,
NBTE- All o¢ fha below m~y roe be used
15' series - 12' Series -
15-Q-PC - 1/4' I~ 12-Q-PC - 1/4'
15-T-PC - l/3' I~ la-T-PC - i/3'
15-H-PC - 1/2' b 12~-H-PC - 1/2"
15-TT=PC - 2/3' ~ 12-TT-PC - 2/3'
15-TO-PC- 3/4' ~) la-TO-PC- 3/4'
15-F-PC -Futt (~ 12-F-PC -Futt
4S-SST-PC 4 x 18'
4-EST-PC 4 x 15'
4-CST-PC 4 x 30'
Sleeve Size
10' Series -
tO-O-PC - 1/4' b
10-T-PC - 1/3' b
lO-H-PC - 1/2' D
iO-TT-PC - 2/3' ~)
10-TO-PC - 3/4" ~)
lO-F-PC - FuU 0
8' Series -
8-Q-PC - 1/4'
8-T-PC - 1/3~
8-H-PC - 1/8~ ·
8-TT-PC - 2/3'
8-TO-PC - 3/4'
8-F-PC -Futt
6' POP-UP FLOOD BUBBLER -
Toro 570 Series MPR Pressure
Compensa~in9 Nozzles as Required,
SYSTEM.:.DESIGN OPERATING PRE¢S~RE =
Between 35 and 40 psi,
4' POP-UP ROTOR -
Hunter PGM Rotor W/
Appropriate Nozzte as Required
Main Line Thrust Blocks
NTS
It~I~IQATION NOTES:
Piping:'
Main Lines: PVC SDR 26, Class 160 Solvent Weld.
Zone Lines: PVC; 1/2 in. and 3/4 in. are not Used.
200 PSI: 1-1/4 in. end greater = SDR 26, 160 PSI.
All end of the line unmarked pipe = 1 in. (min.).
Min. pipe is 1 in.
All solvent weld.
,315 PSI: 1 in. = SDR 21.
Sleeves and suction Line: PVC, SCM 40.
Fittings: SCH 40 PVC
Fabrication: To manufacturers specifications;
joints.
Use blue or grey PVC cement, square cut, clean and prime ail
Allow all main lines to cure for 24 hours before pressuring.
Ail pipe, fittings, and solvents to conform to latest ASTM specs.
Depth of Lines:
Main Line and wiring = 18 in. depth, min.
Sleeving under pavement = 24 in. depth, min.
Suction Line = 24 in. depth, nominal.
Zone Unes 1-1/2 in. and smaller = 10 in. dap[Ih, min.
Control Wires:
AUG 14 for all hot wires and AUG 12 for common.
Solid copper type UF UL listed for direct burial.
Run wires under main and tape every 20 feet.
Run spares, two min.
Splice wires only in a valve box. All splices i shalt be moisture proof using
Snap tile or DBY UL connectors.
Common shall be white, hot shall be red or color coded.
Spare shall be black. Run in conduit where no Main line runs.
Backfill all trenches free of debris, compact to original density, flush all lines, use screens in all heads, adjust
heads for proper coverage avoiding excess water on wails, walks, abc.
All details are graphically shown only. All quantities shall be verified by the contractor prior to installation. It
shall be the contractors responsibility to assure complete overlapping coverage. Any discrepancies shall be
reported to the owner and landscape architect before proceeding. Codes and local regulations shall take
precedence over these plans, it is the contractors responsibility to comply. The landscape architect reserves the
right to make minor field changes, the contractor may field adjust spray nozzle selection to provide for proper
100% min. coverage.
Provide owner with an accurate as installed plan(s) at completion showing main lines, wiring, valves,
crossings, etc. using dimensions from fixed datums.
Contractor shall verify all underground utilities prior to commencement of work.
The perimeter irrigation and landscape may be required to be installed prior to either or both pump stations
and all main line / valve wiring. A separate plan showing modificallions and alternate water source will be
provided prior to construction. The modifications will not impact upon the design intent or substantially
affect-the construction plan.
4-G' Pop-up
Spray or
Bubbler
~' MPl~ Nozzle
~,,,,.,.....- Install sprinkler at finished grade.
Thick walled poly pipe and
barbed els. Toro funny. Rainbird
swing or hardie Blue Stripe.
w'ing joint SCM 40
I'~'l t,----- Lateral pipe ,
4 or 6" Pop-up Spray / Bubbler Detail
NTS
OCT 15 200~
CORRECTED FILE COPY
BUILDING DIVISION
RECEIvED O NOT
SEP-1 0 200~
· 'FILE COPY-
I I I
OOOO ...
Sheet Description
Irrigation Plan
Retease Date
12 -25-05
Project Number
057&
Drawing Number
'Cc Of'
11