Loading...
G1.0 PROJECT INFORM CONTACTSABBREVIATIONS: 3PL ABS AC ACC ACT ADJ AFF ALUM AMP APPROX ARCH BD BLDG BLKG BOB CAB CD CKT CLG CLR CM CMNT CMU CNIRS CO CTR CL COL ~ COMP CONC CONT CONST CT CW CWF' CWN CWS CXFMR DEC DIA DIM DISP DN DTL DW DWG(S) EA EC ELEC ELEV EQ EQUIP EXIST EXP EXT FCO FFE FI FIN FIO FIXT FLEX FOC FOG FOIC FOS FRP FLR FT FV GA GALV GC GRND HC HD HDR HDWD HDWR HM THIRD PARTY LOGISTICS ACRYLONITRILE BUTADIENE STYRENE AIR CONDITIONING ACCESSIBLE ACOUSTICAL CEILING TILE ADJUSTABLE ABOVE FINISHED FLOOR ALUMINUM AMPERAGE APPROXIMATE ARCHITECTURAL BOARD BUILDING BLOCKING BOTTOM OF BEAM CABINET CONDENSATE DRAIN CIRCUIT CEILING CLEAR/CLEARANCE · CONSTRUCTION MANAGER CEMENT CONCRETE MASONRY UNIT CENTERS · COMPANY CENTER CENTER LINE COLUMN COMPARTMENT CONCRETE CONTINUOUS CONSTRUCTION CERAMIC TILE COLD WATER COLD WATER FILTERED COLD WATER NANO FILTERED COLD WATER SOFTENED CURRENT TRANSFORMER DEGREES DIAMETER DIMENSION DISPENSER DOWN DETAIL DISHWASHER DRAWING(S) EACH ELECTRICAL CONTRACTOR ELECTRICAL ELEVATION EQUAL . EOUIPMENT EXISTING EXPOSED EXTERIOR FLOOR CLEANOUT FINISH FLOOR ELEV FUTURE INITIATIVES FINISHED FURNISHED & INSTALLED BY OWNER FIXTURE FLEXIBLE FACE OF CABINET FACE OF GLAZING FURNISHED BY OWNER INSTALLED BY CONTRACTOR FACE OF. STUD FIBERGLASS REINFORCED PANEL FLOOR FOOT/FEET FIELD VERIFY GAUGE GALVANIZED · GENERAL coNTRACTOR GROUND · GYPSUM WALL BOARD HOLLOW CORE HEAD HEADER HARDWOOD HARDWARE HOLLOW METAL HORZ HR HT HVAC HW ID IF IG INSUL INFO IW dC LL MAX MC MDF MECH MEP MERCH MFG MIN MLDG MTL NAT NIC NL NSF NTS OA OC OD:" Of OPNG PC PERP PLAM PLCS PLEX PLYWD PM POC POS PT QT R RCM RECEPT REF REFRIG REQ('D) REV 'RND RO SC SF SHT SHT MTL SIM SOL · SPECS SQ SS STG STRUCT STL SUSP SW T&G TEL TEMP . UC UON VVAL VCT VERT VIF WMV XFMR HORIZONTAL HOUR HEIGHT HEATING VENTILATING AIR CONDITIONING HOT WATER INSIDE DIAMETER INSIDE/INTERIOR FACE INDEPENDENT GROUND INSULATION INFORMATION INDIRECT WASTE JOB CAPTAIN LANDLORD MAXIMUM MECHANICAL CONTRACTOR MEDIUM DENSITY FIBREBOARD MECHANICAL MECHANICAL, ELECTRICAL. AND PLUMBING ' MERCHANDISE UNIT MANUFACTURER MINIMUM MOULDING. METAL NATURAL NOT ~N CONTRACT N~GHT LIGHT NATIONAL SANITATION FOUNDATION NOT TO SCALE OVER ALL · ON CENTER OUTSIDE DIAMETER OUTSIDE FACE OPENING PLUMBING CONTRACTOR PERPENDICULAR PLASTIC LAMINATE PLACES PLEXlGLAS . PLYWOOD PROJECT MANAGER POINT OF CONNECTION POINT OF SALE PAINT QUARRY TILE RADIUS RENOVATIONS CONSTRUOTION MANAGER RECEPTACLE REFERENCE REFRIGERATOR REQUIRE(D.) REVISED/REVISION' ROUND REVERSE OSMOSIS SOLID CORE SQUARE FEET SHEET SHEET METAL SIMILAR SOLID SPECIFICATION(S) SQUARE STAINLESS STEEL STORAGE STRUCTURAL STEEL SUSPENDED SOFTENED WATER TONGUE AND GROOVE TELEPHONE TEMPORARY 'TEMPERED WATER TYPICAL UNDERCOUNTER UNLESS OTHERWISE NOTED' VENT VALIDATION VINYL COMPOSITE TILE VENDOR DIRECT VERTICAL VERIFY IN FIELD · WOOD WATER HEATER WHITE MAPLE VENEER TRANSFORMER GEN EFL L NOTES: .2. AFTER STARBUCKS ACCEPTS THE BID FROM THE GENERAL CONmACTOR (GC), IF THE GC HAS NOT ALREADY DONE SO FOR A PRIOR JOB, THE GC SHALL ]~Egl'EW AND EXECUTE STARBUCKS CONSTRUCTION MANAGEMENT AGREEMENT AND FOLLOW ITS REQUIREMENTS. OC SHALL VISIT THE SITE, REVIEW THE BUILDING SHELL DRAWINGS AS SUBMITTED BY THE LANDLORD OR STARBUCKS SITE SURVEYOR, AND BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO BIDDING OR CONSTRUCTION. GC SHALL CONSULT WITH STARBUCKS CONSTRUCTI'ON- _- MANAGER (CM) TO RESOLVE ANY CHANGES, OMISSIONS OR PLAN DISCREPANCIES PRIOR TO BIDDING OR · CONSTRUCTION 4. FOR EACH PROJECT GC SHALL SUBMIT TO STARBUCKS CMA COMPLETE "CONTRACT PACKAGE" AS DESCRIBED IN THE CONSTRUCTION MANAGEMENT AGREEMENT AND EXECUTE STARBUCKS CONTRACT COVER SHEET FOR THE PROJECT PRIOR TO STARTING CONSTRUCTION ON THE PROJECT 5. GC SHALL COORDINATE, ACCEPT, AND MANAGE ALL PORTIONS OF THE WORK AS ' DESCRIBED IN THE CONTRACT DOCUMENTS, WHICH INCLUDE, BUT ARE NOT LIMITED TO, CONSTRUCTION MANAGEMENT AGREEMENT, CONSTRUCTION SPECIFICATIONS, ARCHITECTURAL DRAWING AND MECHANICAL AND ELECTRICAL DRAWINGS. 6. ALL WORK SHALL BE pERFORMED IN STRICT COMPLIANCE WITH .LOCAL, COUNTY, STATE AIND FEDERAL CODES AND ORDINANCES. 7. OC SHALL.' VERIFY THE LOCATION OF ALL, UTILITIES. 8; GC TO MERIFY ALL DIMENSIONS, INCLUDING CLEARANCES REQUIRED BY OTHER TRADES, AND NOTIFY STARBUCKS CM OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH .THE WORK. ALL DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL DIMENSIONS. TO BE TAKEN FROM DESIGNATED DATUM POINT. DO NOT SCALE DRAWINGS. g. GC SHALL PATCH AND REPAIR ALL ExiSTING WALLS, FLOORS, CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF THE WORK. 10. THE OC IS RESPONSIBLE FOR OBTAINING PERMITS FOR FIRE. PROTECTION, PLUMBING, MECHANICAL AND ELECTRICAL SYSTEMS PRIOR TO INSTALLATION. OF SUCH SYSTEMS. 111 GO SHALL RETAIN ONE SET' OF THE' PLANS TO NOTE AND DOCUMENT ALL CHANGES DURING CONSTRUCTION. THIS SET SHALL BE A PART OF THE GC'S "STORE CLOSE-OUT PACKAGE" AS DESCRIBED IN THE CONSTRUCTION MANAGEMENT AGREEMENT. 12. GC IS RESPONSIBLE FOR COORDINATING DELIVERY OF MATERIALS FROM STARBUCKS CONTRACTED THIRD PARTY LOGISTICS (3PL) DISTRIBUTION SERVICES' AND VENIDOR DIRECT VD) MEF (ODSTH SHIPMENTS. 'REFER TO CONSTRUCTION MANAGEMENT AGREEMENT FOR AND LEAD TIMES. 13. RESPONSIBILITY FOR SUPPLY AND DELIVERY OF MATERIALS AND EQUIPMENT.IS IDENTIFIEID IN THE DRAWING SCHEDULE SHEETS UNDER THE COLUMN LABELED "SHIP". "CC" MEANS THE ITEM IS TO BE SUPPLIED BY THE CC. "3PL" MEANS AN ITEM IS SUPPLIED BY STARBUCKS VIA STARBUCKS CONTRACTED DISTRIBUTION SERVICE AND "VD" MEANS SUPPLIED 'BY STARBUCKS AND SHIPPED DIRECTLY TO THE SITE FROM THE VENDOR. FOR THE PURPOSE OF THE DOCUMENTS, TO "INSTALL" SHALL MEAN TO PROVIDE. ALL FASTENERS, MISCELLANEOUS HARDWARE, BLOCKING, ELECTRICAL CONNECTIONS, PLUMBING CONNECTIONS, AND OTHER ITEMS REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION, UON. LEGEND: ~ NORTH ARROW ,-m 0'-0" BENCHMARK , ~d~(/--SECTION NUMBER './"1'~ sEcTION '~~SHEET NUMBER 1~3 ELEVATION (DETAIL NUMBER. DETAIL BUBBLE. '~ SHEET NUMBER IPXX-E/S] 'e I+×'-×x- I CENTER LINE PAINT/RNISH TAG' REVISION. DATUM POINT AFF HEIGHT TAGS DOOR NUMBER EQUIPMENT TAG WALL TYPE TAG WALL BLOCKING TAG 01234 8 1 REVIsIoN CLOUD SCALE BAR 6'-7 3/¢" DIMENSION LINE FROM FINISH FACE TO FINISH FACE LEGAL DESCRIPTI EXII1B · ~TATUTO RY WARRANTY (I oeRal l)e~cription of Property i.;4 C/L/TI' NO. 4720.T - 310 NORTH CONGRE, A parcel o1' laml in Scclion 29, Township 'l.tc~lch Cm,niy, Florida. m0rc particularly Fn,n Ihe Norlhwesl comer of .Section County. Florida. run Norlh 87" 43' 4g" Ea5~ the center linc of SRIIc Road 804 ,s same apl 217 lhmugh 220. Public Rec~ of Palm and all hem'ing~ ~cited herein m~ r~huivc South O" 58' 29" East a distance of 4 I. Beginning of thc hc~in dcacribed panel of land ~ect: d~eucc Suulh 0" 58' 29" ~st a nodhcrly Right o~ Way of al~msaid Stme northerly Right of Way linc a distance or Nodhca~ having a radius o1' 25.0 f~et and N~)~hcriy along arc of said cu~e, a distance of a linc parallel ~o n,d 60.0 f~et 15asterly from aforesaid Sccdon 29; thence along said parallel ~el la ~he Point or Beginnhlg. l.ess tidal portion conveyed Io Palm Beach or Palm Beach Counb,, FIo~da. PI:.RMITT'ED ENCUMBR/flVCE, Y,: CODE 'OVERVIEW STATE AGENCY JURISDICTION: FLORIDA DE LOCAL PERMIT AGENCY: PALM BEACH COU[ OCCUPANCY BY AREA CALCULATION: 37'P£ OCCUPANCY: MERCANTILE-GROUP M PER RESTROOM UIREMENTS: ONE UNISEX R 403.2.4 ION: APPROVAL STAMPS: PROJECT CONTACTS: *~~ PROJECT MANAGER: MARK BROWN ~'~,,i~t ~ Encmnbr~~n~s) STARBUCKS COFFEE COMPANY ..~. . . 2401 UTAHA~NUESOU~ , ~ '~" (206) 318-4039 PHONE Soul, S, Range ~3 Earl, C]I~ o~8oynlon I{each.~ P~lm PLACE FIRE EXTINGUISHER crib~ a~ rollow~: WITHIN 10' OF ~AIN EXIT DOOR ' ~ ~ CONS~UC~0N MANAGER: L%E KRUMLAUF -- 'l~hii) 45 South. Range 43 East. Pahn Rtmcli ~ ;: 4307 ~NELAND, STE H-19 dond Ibc North line of Section 29 (for conve, icnce. ORLANDO, FL 32811 ;" ' ~ t',,c. APPROVED PLANS AND mcli ~]Om~ly. Florida, hours North 87' 54,' 06" Easi PERMIT CARD MUST BE (407) 688-2104 FAX hcre~O,, dis,...ce .r (,o.01 r~ct to a point; mcn<:~. ON THE JOB FOR ANY COFFEE COMPANY ' 9 !~:~{ ~o Ihe Non~terly comer and Point o1' md: ~mn~c North 87 43' 48" East a distance nr 300 INSPECTION TO TAKE P~CE ~ LANDLORD: . J0N M0~ 2401 UTAH AVENUE SOUTH cc ~( 175,(H t~et. mom or less. Io, poin~ i. I1~' BY THE FIRE DEPARTMENT. ~E PARADISE DEV. GROUP INC. SEATTLE, WASHINGTON 98134 ),~d~04: Ihm~cc Somh g7 54 06 Wes{ ak n= s,~d 2901 RIGSBY LANE (206) 318-1575 LS~:.~bcl to Ibc I)cginning oi'a cun, e concave h) Iht : SAFE~ HARBOR, FL 34695 - ~ESE P~NS AND ~E~RCA~ AS ~ AS CCrJt~i] antic ur 91 07' 25': Iht,ce Wc~M. crly and ' :' ~ (727) 726-1115 PHONE STraUSS' N~E AND L~, mADEU~KS AND ~I' ~9.7~ I~[ to Iht cml of said cu~'e and a pninl on . DE~S ~E ~E ~CLUSI~ PROP~ OF ~' ; ST~BU~S CORPORA~ON. ~Y R~R~UC~ON, wl~n.nm~sur~l al right [mglL~ !o ibc W,cm flue o1' ' ~ : M~IRCA~, DIS~OSURE Icl HOe North O' 5~' ~9 Wesl, a dislanc~ or 149.5~ LANDLORD CONTACT: · MICHAEL ~ISS ~E~ MA~IALS (OR ANY POR~ ~ ~) "~E PARADISE DEV. GROUP INC. .~ s~.auc~s' ProC. ~ C~T , 2901 RIGSBY LANE m.~'in O,R. I]ook ~07,.. Page _gg.~ Public R~:ord~ SAFE~ HARBOR, FL 34695 ARCHITECT ' ARCHI~CT: ROBERT BURKE ~' · ~ BURKE HOGUE A MILLS ASSOCIA~S 100 COLONIAL CEN~R PARKWAY, SUI~ 150 LAKE MARY, FL 327~6 (407) 629-4511 PHONE BURKE, HOGUE A MILLS (407)' 629-9070 IFAX ASSOCIATES~ INC ~-C000233 I00 ~ ~ P~AY, SU~ ]~0 ~E ~. ~ 32746 MEP CONSULTANT: BOB CONNERS KAMM CONSUL~NG ARCHITECT OF RECORD: 6 FAIRFIELD BLVD, SUI~ 7 ROBERT H. BURKE, dr. AR 6478 PON~ ~RDRA BEACH, FL 32082 REV DATE dC DESCRIPTION (904] 285-3009 FAX . PROJECT INFO A SITE SHEETS: Gl.0 PROJECT INFORMA~ON ~ CONTACTS :~ G2.0 ~ClNI~MAP, SI~ LOCA~ON, A FLOOR PLAN SEPARATE REQUIRED =~TMENT..~ OF AGRICULTURE ' FOR~~' ' A,.oAO'I EXTERIoRFLOOR ,ENE~A~ONELEVA~oNsPLAN' . A2.0 CONS~UC~ON PLAN (~PLE A3.0 REFLEC~D CEILING PLAN / LIGH~NG DNENSIoN PLAN '~' A&I CEILING DETAILS ' ~C SECTION 310.1 (LESS THAN' 50 PEOPLE) , A~.O FLOOR FINISH PLAN A DETAILS ':j . A5.0 WALL FINISH PLAN ~ SCHEDULES ,~T ROOM PER FLORIDA PLUMBING 'CODE, A5.1 IN~RIOR ELEVA~0NS ~, A5.2 NOT USED ., A7.0 CASEWORK PLAN ~ SCHEDU~S m g 0 0 0 < ~E OF USE: RETAIL SALES AND SER~CES - · ~ . ~E OF OCCUPANCy: MERCHAN~LE ~ z MECHANICAL / PLUMBING / ELECTRICAL 'SHEETS: :" o ~E OF CONS~UC~ON~ V UNPRO~C~D .SPRINKLERED - ~ o MI.0 MECHANICAL SPEClFICA~ONS A NO~S PROJECT NO. 23994-00 . M2.0 HVAC PLAN A SCHEDULE STORE~ 8805 DESIGN 'CODE SUMMARY FLORIDA BUILDING CODE 2001 ' M3.0 MECHANICAL DETAILS CONCEPT:23994-OOl_867i APPUCABLE CODES: FLORIDA PLUMBING CODE 2001 ISSUE DATE: 8-24-04 ,: . FLORIDA MECHANICAL CODE 2001 Pl.0 PLUMBING SPEClFJCA~ONS ' PM: MARK BROWN . NATIONAL ELECTRICAL CODE 2002 P2.0 .PLUMBING SUPPLY PLAN A SCHEDULE ' FLORIDA GAS CODE 2001 JC: DANICAsTEAD " FLORIDA FIRE. PR~ENTION CODE 2001 P3.0 PLUMBING WAS~ / DRAIN PLAN P~.O PLUMBING DETAILS REVIEWED CHECKED: TARA DINAPOLI DE,RAGE/PREP: 156 S.L/200=2 'E&O LIgH~N~ PLAN A SCHEDULES · ~[~. ~ (DO NOT SCALE DRAWINGS) WORKROOM/STORAGE: 237 S.F./300= 3 E~.O ELEC~ICAL DETAILS ' EL ECT~ICA~ · · ESTIMATED COST 0F CONSTRuCTIoN: ~ 90,000. ~ ,-,~:.:.~ ._/,~~~ ~ E C ~ ~V E :': ~FILE COPYe . ,, ]BUILDING DlVlSiO~ PROJECT CODE:23994-001 8677 file:p~th" J: CAD /PROJECTS / FL / 25994-001