MO.1 MECHANICAL NOTES,J L~.C&L1U C ' /UU~"UQUOP,q U' I 'MU. I .i-'g II ' 13t I i::i/U~. I: JQ:~
FAN SCHEDULE
~ ~ DATA FAN DATA MOTOFI DATA ~ DATA '
WEIGHT DIMENSIONS OPENING
TAG SERVICE AREA MANUF.(*) MODEL CONFIG. CFM ESP ("WG) SONES HP RPM DRIVE VOLTAGE (LBS) L"xW"xH" L"xW" CONTROL ACCESSORIES
EF-1,-2 GUEST TOILET GREENHECK SP-6 CEILING 75 .375 3.0 40 WATI' 1500 DIRECT 120/1/60 6 18X12x8 * LIGHT INTERLOCK SEE NOTES
EF-3 WAREHOUSE GREENHECK GB-131-5 ROOF 2000 .25 15.3 1/2 1498 BELT 460/3/60 60 19x19x24 14.5x14.5 SWITCH SEE NOTES
(*) APPROVED EQUAL MANUFACTURER: COOK, TWIN-CITY, ACME, PENN GENERAL FAN NOTES:
ACCESSORIES NOTES: a. MOTOR STARTERS, DISCONNECTS (IF NOT FACTORY PROVIDED) AND ALL EQUIPMENT
1. PROVIDE GRILLE COLOR PER ARCH. SPECS NORMAL POWER WIRING BY. ELEC. CONTRACTOR
2. PROVIDE BACK DRAFT DAMPER ' b. ALL CONTINUOUS-DUTY MOTORS SHALL BE PROVIDED WITH OVERLOAD PROTECTION
3. PROVIDE FACTORY MOUNTED DISCONNECT SWITCH AND INTEGRAL THERMAL OVERLOAD PROTECTION, ACCORDING TO NATIONAL ELECTRICAL CODE PAR. 450-32.
COORDINATE WITH ELECTRICAL CONTRACTOR PRIOR TO ANY PURCHASING.
8. PROVIDE ROOF CURB c. FIELD ADJUST OPENINGS WITH STRUCTURE.
9. PROVIDE MINIMUM TWO BELTS d. ALL OUTDOOR EQUIPMENT SHALL COMPLY WITH LOCAL ZONING NOISE
13. PROVIDE BIRD SCREEN ' ORDINANCE OR NOT EXCEED A NOISE LEVEL OF 65dB AS MEASURED
14. LOCATE BACK DRAFT DAMPER AT DISCHARGE RADIALLY 30 FT. FROM THE EQUIPMENT IN ALL DIRECTIONS.
18. SUPPORT FROM STRUCTURE COMPLETE WITH VIBRATION ISOLATORS e. COORDINATE WITH ELECTRICAL CONTRACTOR BEFORE BIDDING OR
27. PROVIDE ROOFCAP ORDERING ANY EQUIPMENT.
f. sEE PROJECT PLANS AND SPECIFICATIONS FOR OTHER FIELD SUPPLIED ITEMS
AND' ADDITIONAL INFORMATION.
g. ALL FANS ON ROOF SHALL! BE PAINTED AS PER ARCHITECTURAL SPECS.
OUTSIDE AIR CALCULATIONS
(PER TABLE 2, ASHRAE 62-89)
AREA SERVED NET OCCUPIABLE MAX. OCCUPANCY TOTAL NO. VENTILATION RATE TOTAL CFM TOTAL CFM NOTES
OR UNIT TAG AREA SO. FT. P/lO00 SO.FT. OF PEOPLE CFM/P OR SO.FT. O/A REQUIRED O/A PROVIDED
OFFICE 1161 - 11 20 220 220 1,3
WAREHOUSE 6900 - - .05 PER SQ/FT 345 2000 1,3
1. CALCULATIONS ARE BASED ON ESTIMATED MAX. O'CCUPANCY RATES PER ARCHITECTURAL PLANS AND ASHRAE 62-89.
VENTILATION RATES PER ASHRAE 62-89.
2. FOR ASSEMBLY ROOMS, CONFERENCE ROOMS AND OTHER SIMILAR AREAS CALCULATIONS ARE BASED ON
INTERMITTENT OR VARIABLE OCCUPANCY IN CONFORMITY WITH PAR. 6.1.3.4 OF ASHRAE 62-89.
,:3. FOR OFRCE AND OTHER SIMILAR AREAS CALCULATIONS ARE BASED ON CONTINUOUS OCCUPANCY
AIR BALANCE SCHEDULE
AREA EQUIPMENT SUPPLY AIR RETURN AIR OUTSIDE AIR MAKE-UP AIR EXHAUST AIR
SERVED TAG (CFM) (CFM) (CFM) ' (CFM) (CFM)
OFFICE '... RTU_i 2200 1980 220 - i -
Ef-1 I , 75
TOTAL 2200 1980 220" - 75
1. BUILDING IS220-75=145 POSITIVE WHEN ALL EXHAUST FANS OPERATING
ROOFTOP A/C EQUIPMENT SCHEDULE
A/C UNIT TAG RTU-1
MANUFACTURER CARRIER
IMODEL 50H JO06
TOTAL SENSIBLE CAP. MBH. 49.63
'TOTAL COOLING CAP. MBH. 60.10
ENT. AIR TEMP D.B./W.B. 'F 77.6/63.5
LEAV.: AIR TEMP D~B./w's. 'F 56.7/54;:$
:SUPPLY AIR CFM 2200
~OUTSIDE AIR CFM 220
460/3/60
VOLTAGE
]MCA/MOCP 20.5/25
SEER/ERR 13.0
,OPERATING WEIGHT LBS. ~ 465:
DIMENSIONS L x W x H (IN.) 73.7X45X33.3
REF./LBS. R-22/5LBS 130Z
NOMINAL .TONNAGE/STAGES 5/1
NO. OF ~C6~iPREsSORs ' ~ i
COMP. R.LA. EACH 9
Of OUTDOOR FANS 1
FAN FLA: EACH .8
INDOOR FAN TYPE FC
FAN E.S.P. (IN. W.G.) 1.0
FAN H.P./B.H.P. 2 BHP
FAN F.L.A,. .. 2.6
COIL ROWS/FPI
HEATER TYPE ELECTRIC.
HEATER K.W. 0 RATED VOLTAGE 11.50 460V/5~
NO. OF STEPS
FILTER TYPE/EFF.: '
1
1- THROWAWAY/30% ::
1. UNITS SHALL BE "ARI" RATED.
LENNOX,
2. PROVIDE
INSTALL
3. PROVIDE
4. PROVIDE
5. PROVIDE
6. PROVIDE
7. PROVIDE
8. PROVIDE
9. PROVIDE
10. PROVIDE
11. PROVIDE
12. PROVIDE
APPROVED EQUIVALENT: AAON,
McQUAY, TRANE
FACTORY BUILT ROOFCURB i4"(0R 20" IF NECESSARY) HIGH,
UNIT LEVEL WITHIN PRESCRIBED TOLERENCES (SEE DETAIL)
COMPRESSOR 5--YEAR WARRANTY
SLOPED CONDENSATE DRAIN PAN AND INTERNAL TRAP.
MANUAL OUTSIDE AIR DAMPER .
SERVICE CLEARANCES PER MFGR'S RECOMMENDATIONS.
SINGLE POINT POWER ENTRY.
FACTORY MOUNTED FUSIBLE DISCONNECT, COORDINATE PRIOR TO PURCHASING
INTERNAL SPRING ISOLATION FOR SUPPLY FAN.
MOTOR OVERLOAD AND THERMAL PROTECTION.
MATCHING PROGRAMMABLE THERMOSTAT FOR CAPACITY STAGING
ELECTRONIC CONDENSATION CONTROL SYSTEM FOR DRAIN PAN(S).'
AIR DISTRIBUTION SC:HEDULE
TAG MANuF. & MODEL; FAce SIZE NECK"Size MATERIAL FRAME FINISH.. DAMPER
·
. SEE ALUM. LAY'IN OFF'WHITE 'OBD
A, METALAIRE 5800 A-6 24x24 SOHEDUII:
B METALAIRE 5800 A-6 12X12 SCHEDULE ALUM: LAY-IN OFF'WHiTE ODD
AA METALAIRE 765ORAL-6 24X24 6X6 ALUM. LAY-IN OFF WHITE =- -
(*) EQUIVALENT MANUFACTURER:. TITUS, METALAIRE, CARNES, T & B, NAILOR
1. PROVIDE SPIN-IN COLLAR WITH VOLUME DAMPER AT TRUNK TO FLEX DUCT CONNECTION (SEE DETAIL).
2. PROVIDE TYPICAL 4--WAY DIFFUSION, 2--WAY OR 3-WAY ONLY WHERE INDICATED ON PLANS.
3. REFER TO ARCHITECT PLANS FOR CEILING TYPE.
4. FINAL COLOR SELECTION SUBJECT TO ARCHITECT APPROVAL.
5. FLEX DUCT SIZE TO BE SAME AS DIFFUSER NECK SIZE.
6. PROVIDE INSULATION ON THE BACK OF DIFFUSER IF IN UNCONDITIONED SPACE
7. PROVIDE VOLUME CONTROL DAMPERS FOR ALL RETURN GRILLES OR REGISTERS FOR BALANCED AIRFLOW.
THROW NC CFM RANGE NOTES
4-'WAY MAX. 3O
2-WAY
MAX. 30
sEE SCH. *
SEE SCH: *
· ,
$/A ~ ~
6~" 50-125 CFM
8~" 130-200 CFM
10~" 205-330 CFM
12~" 335-450 CFM
14e" 455-700 CFM
:CONTRACTOR SHALL VERIFY WITH ARCHITECT AND TENANT/OWNER,
PRIOR TO ANY PURCHASING OR INSTALLATION, IF A BULDING
STANDARD HAS TO BE FOLLOWED REGARDING A SPECIFIC MODEL
OR MANUFACTURER AND SHALL BRING ANY DISCREPANCY TO
THE ATTENTION OF ENGINEER.
MAX. 3,0
MECHANICAL NOTES
04-2865
1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT 'NECESSARY
FOR THE INSTALLATION OF A COMPLETE SYSTEM IN ACCORDANCE WITH THESE
DRAWINGS, THE FLORIDA BUILDING CODE 2001 AND ALL OTHER APPLICABLE STATE,
COUNTY AND LOCAL ORDINANCES AND THE LATEST ADDITION OF THE FOLLOWING
PUBLICATIONS; SMACNA-92, 95; ASHRAE 15-94, 34-92, 62-89; NFPA 90A-99, 90B-99,
91-95, 96-98; ANSI 210.1-98, 210.5-98, 221.8-94, 221.13-91.
2. THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL~ OTHER
COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK.
3. THE CONTRACTOR SHALL VISIT THE SITE AND COORDINATE WORK WITH OTHER TRADES.
4. THE CONTRACTOR SHALL SUPPLY THE .ARCHITECT WITH "AS-BUILT" DRAWINGS.
CONTRACTOR SHALL SUBMIT, FOR APPROVAL FIVE [5] COPIES OF MANUFACTURER'S
DRAWINGS FOR EACH PIECE OF EQUIPMENT AND CONTROLS INCLUDED IN CONTRACT.
ALL MATERIAL SHALL BE NEW OF U.S. MANUFACTURER Of GOOD QUALITY. All WORK 'SHALL
BE PERFORMED AT INDUSTRY STANDARD QUALITY LEVEL BY CERTIFIED PROFESSIONALS.
ALL EQUIPMENT SHALL BE UL OR RTL LISTED.
7. DUCTWORK: :
ALL AIR CONDITIONING DUCT WORK SHALL BE OF 1-1/2" (R-6) HEAVY DUTY FOIL
REINFORCED FIBERGLASS WITH MANUFACTURER'S LOGO PRINTED ON VAPOR BARRIER
ALL FLEX TO BE R-6.
8. All EXHAUST DUCTS AND OUTSIDE AIR DUCTS SHALL BE GALVANIZED SHEET METAL
WITH SEALED 'SEAMS AND JOINTS. ALL OUTSIDE AIR DUCT SHALL BE INSULATED WITH
EXTERNAL BLANKET INSULATION R-6 MIN.
9. OUTSIDE AIR INTAKES SHALL BE SCREENED WITH A CORROSION RESISTANT MATERIAL NOT LARGER
THAN 1/2" MESH. O/A INTAKES SHAll NOT BE TAKEN FROM A LOCATION CLOSER THAN 10 FT.
FROM ANY 'CHIMNEY, VENT OUTLET OR SANITARY SEWER VENT OUTLET, UNLESS SUCH VENT
IS NOT LESS THAN 24 INCHES ABOVE THE OUTSIDE AIR VENT.
OUTSIDE AIR INTAKE VENTS LOCATED ON ROOFS WILL BE PROPERLY MARKEI~ WITH A UNIVERSAL
MARKING 'INTAKE", PERMANENTLY ATTACHED PER IBC 2001, SEC. 2810.
10. DUCT SIZES SHOWN ARE INSIDE DIMENSIONS.
11. ALL AIR DEVICES (DIFFUSERS,' REGISTERS AND GRILLES) SHALL BE All ALUMINUM
CONSTRUCTION WITH EXPOSED SURFACE OFF WHITE BAKED ENAMEL FINISH OR AS
SPECIFIED BY ARCHITECT. DEVICES SHALL BE AS SPECIFIED OR EQUAL TO TITUS OR METALAIRE.
PROVIDE OPPOSED BLADE DAMPERS AT ALL DIFFUSERS AND REGISTERS AS INDICATED ON
PLANS OR BALANCING DAMPERS AT BRANCH DUCT CONNECTION TO ENSURE COMPLIANCE
WITH F'BC 2001, PAR. 601.4 FOR BALANCED AIR FLOW.
12. THERMOSTAT SHALL BE COMBINATION COOLING/HEATING, WITH SYSTEM "coOL-AUTO-
HEAT-OFF" AND FAN "ON-AUTO" SELECTOR SWITCHES. PROVIDE PROGRAMMABLE TYPE AS
RECOMMENDED BY MANUFACTURER, HONEYWELL OR EQUAL. PROVIDE TAMPER PROOF COVERS.
1,3. All BRANCH TAKE-OFFS TO BE PROVIDED W/ MANUAL VOLUME DAMPERS. :'All ELBOWS
AND TEE'S MUST BE FURNISHED W/TURNING VANES, PROVIDE MANUAL VOLUME DAMPERS
WITH EXTRACTOR AT ALL FLEX TAKE-OFFS.
14. PROVIDE NEW FILTERS FOR ALL AIR CONDITIONING EQUIPMENT BEFORE START-UP,
REPLACE PRIOR TO FINAL ACCEPTANCE BY OWNER.
15. PROVIDE SMOKE DETECTORS WITH SERVICE ACCESS DOORS IN ALL SUPPLY AIR DUCTS
FOR FANS AND AHU'S SERVING A COMMON PLENUM OF 2000 CFM OR ABOVE.
FOR SMOKE DETECTORS NOT VISIBLE, IN CONCEALED SPACES, PROVIDE REMOTE ANNUNCIATION/TEST
STATION AS REQUIRED BY AUTHORITY HAVING JURISDICTION, COORDINATE PRIOR TO INSTALLATION.
DETECTORS SHALL BE BY ONE MANUFACTURER, COORDINATE VOLTAGE ETC. WITH
ELECTRICAL CONTRACTOR AND FIRE ALARM SYSTEM BEFORE ORDERING. UPON
DETECTION, SMOKE DETECTORS SHUT DOWN' ASSOCIATED AIR MOVING EQUIPMENT AND
ALL AIR MOVING EQUIPMENT SERVING THAT COMMON PLENUM.
16. HVAC CONTRACTOR SHALL PROVIDE A T & B REPORT PER f,b.C. 2001, CH.'::13, 410.1.ABCD.4
FOR ALL MECHANICAL EQUIPMENT, AIR'. DEVICES, DAMPERS, AHU'S AND FANS.
THE TEST AND BALANCE REPORT SHAILL BE IN ACCORDANCE WITH THE AIR BALANCE COUNCIL
STANDARDS AND SHALL INCLUDE AIR QUANTITIES FOR ALL SUPPLY GRILLES, RETURN GRILLES
AND EXHAUST GRILLES AND THE LEAVING AND ENTERING AIR TEMPERATURE (T) FROM
SUPPLY GRILLES AND EVAPORATORS.
FOR (EXISTING) SMOKE EVACUATION SYSTEMS HVAC CONTRACTOR SHALL PROVIDE A T & B
REPORT PRIOR TO ANY NEW WORK, PROVING THAT THE SMOKE EVACUATION SYSTEM PERFORMS
PER ORIGINAL DESIGN DOCUMENTS AND IS COMPLIANT WITH LOCAL CODE REQUIREMENTS.
17. THERMOSTAT LOCATION SHALL BE APPROVED BY OWNER AND ENGINEER BEFORE INSTALLATION.
INSTALL THERMOSTAT 48" TO 54" A.F.F. PER A.D.A REQUIREMENTS WHERE APPLICABLE.
MECHANICAL CONTRACTOR SHALL COORDINATE WITH ELECTRICAL CONTRACTOR ALL REQUIREMENTS
FOR JUNCTION BOXES, CONDUITS, CONTROL WIRING, POWER, ETC. AND DEFINE RESPONSIBILITIES
AND SCOPE OF WORK FOR EACH TRADE PRIOR TO ANY PURCHASING OR INSTALLATION.
18. RUN INSULATED FIRE RATED CONDENSATE DRAINS AS REQUIRED.
19. ALL INSULATION WILL HAVE FIRE/SMOKE RATING LESS THAN 25/50.
20. MECHANICAL EQUIPMENT ON ROOF OR ELEVATED STRUCTURES SHALL COMPLY WITH IBC 2001
PAR. 306.5 IF INSTALLED HIGHER THAN 16 FEET
MECHANICAL EQUIPMENT INSTALLED IN ATTICS SHALL MEET THE REQUIREMENTS OF FBC 2001
PAR. 306.3 IF THE EQUIPMENT CAN NOT BE SERVICED/REMOVED THROUGH REQUIRED OPENING.
MECHANICAL EQUIPMENT SHALL BE PROTECTED WITH MECHANICAL BARRIERS IF EXPOSED TO
MECH. DAMAGE. All EQUIPMENT SHALL BE INSTALLED ON 6" CONCRETE PAD AT GRADE LEVEL .
All WIND LOAD AND OTHER COMPLIANCE CALCULATIONS FOR ROOF MOUNTEb EQUIPMENT,
AS REQUIRED BY IBC 2001, PAR. 152.2.2 AND CHAPTER 16, SHALL BE PROVIDED BY
STRUCTURAL ENGINEER/ARCHITECT.
I
21. PROVIDE A MIN. OF 36" CLEARANCE IN FRONT OF ALL 120-208 VOLT PANELS AND MIN. 42"
CLEARANCE IN FRONT OF ANY 240-480 VOLT PANEL. PROVIDE ADEQUATE SIDE
CLEARANCE PER NEC.
22. MECHANICAL PLANS IN GENERAL, ARE 'DIAGRAMMATIC IN- NATURE, AND ARE i'0 BE READ
IN CONJUNCTION WITH ARCH. PLUMBING, ELECTRICAL AND STRUCTURAL PLANS AND
SHALL BE CONSIDERED AS ONE SET OF DOCUMENTS. DUCT AND PIPING OFFSETS, BENDS
AND TRANSITIONS WILL BE REQUIRED TO PROVIDE AND INSTALL A COMPLETE
FUNCTIONAL SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO
ADDITIONAL COST TO THE OWNER. CHANGES IN DUCTWORK SIZE AND ROUTE
WILL BE REQUIRED TO AVOID STRUCTURAL AND ARCHITECTURAL BLDG. FEATURES.
DUCTWORK CHANGES MAY BE MADE BY CONTRACTOR USING EQUIVALENT SIZED DUCT
CONTACT ENGINEER If DUCT AREA WILL NOT FIT.
THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BIDDING, ORDERING,
FABRICATION OR INSTALLATION OF MATERIALS OR EQUIPMENT.
MANUFACTURER'S WARRANTY: CONTRACTOR SHALL PROVIDE WARRANTY FOR A PERIOD OF
(1) ONE YEAR AFTER BUILDING C.O. FOR ALL MECHANICAL SYSTEMS, DUCTWORK, CONTROLS
ACCESSORIES AND ALL OTHER EQUIPMENT, PARTS AND LABOR UNDER THESE DRAWINGS AND
.AN.D SPECIFICATIONS. CONTRACTOR SHALL PROVIDE WARRANTY FOR
(5)' FIVE YEARS. ANY REPAIRS REQUIRING SYSTEM SHUTDOWN WILL BE D~NE~DURIN~
NON-OPERATIONAL PERIODS OR AS AGREED WITH OWNER.
23.
24.
J SHEE
DO
MECHANICAL SHEET INDEX
MOA MECHANICAL NOTES, LEGEND &: INDEX
M2.1 MECHANICAL PLAN
M5.1 NOT USED
JUL-t9 2OFt
CORRECTED FILE C(~Y
BI, liLgJNG DIVISION
-, .,,~..~~ --~:~
ISSUED FOR PE~ 06-18-04
~ ~JE~~~' ~ ~BE~
~~ ~ ~ ~ ~ ~ 1407 We~t Ne~oR C~ter Drive
I ~ ~ ~ ~ ~ ~ Deeffield Beach, Floff~:33442~.
I ~ I~ ~ ~ ~ Phone 954 949 2200 Fax °5~
~m ~ mm m m m m m ~_~ ____ ~ ~____. , · ~;~' ' ~ ~" "~'-
M~ea PelIa Flofi~ gic~se ~8798: ' ~'-- s~,.
V.
ARCHITECTURE LLC
AA26DDD?26
3395 N. DIXIE HWY. SUITE 5
BDnA RATnN~ FLORIDA
T 561 392 5344 f 561 392 5531
WWW,HNM'ARI:HITECTURE, :DM
d.C.: M.W.H.
P,M.: d.D.M.
DRAWN BY: d.O.M.
REVI~;IONS:
PROJECT NAME' : :ii ~' :: ~-':: ~ '
BUCHANAN SCREENS AT
'PREMIER GATEWAY CENTER BLDG, NO.2
IN CITY OF BOYNTON BEACH, FLO DA
MECHANICAI, NOTES
SHEET TITLE
06-10-04
DATE:
SHEET NO.
M0.1