M5.1 MECHANICAL DETAILS*J I.J'~bl UIC ·/UU'~.'UOUOMO~ I -P.'IU. I .i'm I O/U,~. H-..'iD;q-'~ ,r~M WEB 1/4-' ALL THREAD ROD TOP CHORD METAL EXHAUST DUCT VIBRATION ISOLATOR (RUBBER GROMMET) ~'AL CEILING CABINET EXHAUST FAN WITH BACK DRAFTDAMPER, LOW NOISE AND NO VIBRATION. FRONT FACE GRILLE WITH FASTENING SCREWS EXHAUST FAN HANGING BRACKET (ADJUSTABLE) CABINET FAN DETAIL NOT TO SCALE FANS-050 ELBOW TURNiNC~RNv~E AN GLE'~ TEE HANG AH DUCT PER SMACNA STANDARDS CHANNEL STRAP & SADDLE TURNING VANES~[~ CHANNEL--~ PUTIER DAMPER CONTROL ROD W/ LOCK DUCT-.O01 HVAC DUCT DETAILS NOT TO SCALE ARCHITECTURE LLC AA26DOD?2FI 3395 N. DIXIE HWY. SUITE 5 BOnA RATnN, FLORIDA 334.~ 1 T 561 392 5344 F 551 392 55,~1 WWW.H N M'AROHITEDTU~,=n,M ..................................................................... d.C..: M.W.H. P.M.: U.D,M. DRAWN REVISIONS: I~AN. 1~11./ PUl'{ 13.bI.U.(J.l., ZUU1 I-U; DIRECT DRIVE OR ADJUSTABLE PITCH MOTOR SHEAVE AS MOTOR AND DRIVE OUT OF AIR STREAM MOTOR DOME RUBBER ISOLATOR ALL ALUMINUM WHEEL HUB & HOUSING DISCHARGE DOME W/-BIRDSCREEN RUBBER GASKET BETWEEN CURB & FAN H( ANCHOR FAN TO CURB~ WITH LAG SCREWS PER STRUCTURAL PLANS OR MIN. (2) ON EACH SIDE RUN FLASHING Uf UNDER FAN BASE WIRING (BY OTHERS) )ACKDRAFTDAMPER' uL APPROVED DISCONNECT SWITCH UNDER HOOD ,' -- MOTOR VENTILATION OPENING --PRE-FAB CURB 12" HIGH OR AS REQ'D BY LOCAL CODE STRIP FELT FLASHING OVERLAP ROOFING EXHAUST AIR DUCT ROOF STRL WHERE INDICATED ' ': :' .: PROVIDE 3/8" S.S. THRU BOLTS WITH MIN. LENGTH AS DETERMINED By FIELD CONDITIONS TO INSURE PROPER ATTACHMENT TO STRUCTURE, PROVIDE .ANCHORING AT 18" O.C. OR AS 'RECOMMENDED BY STRUCTUR. AL ENGINEER. WELD CURB TO TOP CHORD AS ALTERNATE METHOD. ROOF: MOUNTED EXHAUST F:AN DETAIL NOT TO ,SCALE FANS-035 GOOSENECK SHALL HAVE TERMINATION PARALLEL TO ROOF PLANE TO AVOID. RAIN AND WIND BACKLFLOW CONDITIONS ANGLE REINFORCEMENT RIVETED OR TACK WELDED AS REQUIRED. WATERPROOF SEAMS JOINTS INSTALL METAL INSECT AT DUCT OPENING. GA. GALV. SHEET METAL DUCT+ 25%SIZE METAL FLASHING SHOULD EXTEND 4-" MINIMUM BELOW TOP OF CURB. 14" ROOF METAL ROOF DECK MINIMUM SEAL ALL ROOF PENETRATIONS AT POINTS OF SUPPORT ATTACHEMENT AND REINFORCEMENT. ROOF THRU CURB THROUGH ROOF DECK AND STRUCTURAL FRAMING: GOOSENECK DETAIL NOT TO SCALE DUCT-022 HAN. J'q.u~ ~ J,q-u~ I-UN :5.1-.Id.L;. (UNUWANU ~ UAl)L), l~Jl~ ~-U. PROJECT NAME = ' ' " BUCHANAN SCREENS AT ' PREMIER GATEWAY CENTER BLDG"Noi2 LOCKING QUADRANT TO BE EXPOSED FLEXIBLE DUCT WITH INSULATION & VAPOR BARRIER TIE TO % STRUCTURAL SUPPORTS 2" WIDE METAL BAND SUPPORT SQUARE TO ROUND ADAPTER GALV. STEEL ROD OR STRAP SUPPORTS PER SMACNA STANDARDS SIDE TAKE-OFF FITTING WITH DAMPER, BELL MOUTH OR SHOETAP TYPE MAIN SUPPLY AIR DUCT, SEE PLANS FOR TYPE AND INSULATION /71 NYLON DRAWBAND AND MASTIC AT EACH ON __ ROUND ADAPTER GYPSUM BOARD CEILING 7 ~ ' --1'1/2" X 1-1/2" X 1/8" GALV. ANGLE OR STRAP PER SMACNA CONNECT INNER DUCT WITH DRAWBAND AND SEAL WITH TAPE/MASTIC OUTERDUCT AT NECK CONNECTION PROVIDE THERMAL INSULATION BLANKET IF INSTALLED IN UNCONDITIONED SPACE SUSPENDED TYPE ,. CEILING SYSTEM LOUVERED FACE CEILING DIFFUSER WITH 2' X 2' LAY-IN ALUM. PANEL TYPICAL DIFFUSER DETAIL NOT TO SCALE DIFFUSER-O03 B MAX. ALLOWABLE DIFFERENCE (in) I,,A- B B- C A - C I 0.5 1.0 1.0 ROOFTOP UNIT LEVELING TOLERANCE8 ROOF RIGID INSULATION (SEE ARCH.) 3/8"(#14-) METAL SCREWS AT 18" O.C., LENGTH AS REQUIRED TO INSURE FULL DEPTH NAILER PENETRATION. PROVIDE SPACERS AS REQUIRED TO ACCOMMODATE ALTERNATE LOCATION T PRESSURE TREATED 2X4 WOOD NAILER (METAL STUDS WHERE o REQ'D BY LOCAL A.H.J.) FASTNERS, 16" O.C o z COUNTER FLASHING ,,, (FIELD SUPPLIED) (n BASE FLASHING v (FIELD SUPPLIED) FIBER CANT STRIP SET IN BITUMEN (FIELD SUPPLIED). BUILT UP ROOFING ROOF MOUNTED HVAC EQUIPMENT 1/4.' NEOPI~ENE RUBBER GASKET CONTINUOUS AROUND PERIMETER MIN. 1-1/2", 3 LB RIGID INSULATION WITH NEOPRENE COATING ON EXPOSED SURFACE (FIELD SUPPLIED) GALVANIZED METAL CURB (18 GA. MIN,) SECURE CURB TO ROOF WITH STAINLESS OR GALV. STEEL BOLTS SEE NOTE # 9 FOR SIZE AND NO. (WELD CURB TO TOP CHORD AS ALTERNATE LIGHT WEIGHT /' ss // \\ (SEE ARCH.) ,: :,, : // JOIST WEB- " JOIST TOP CHORD -- WASHER AND 1. -i '2. 3. 4-. 5. 6. 7. ROOFTOP UNIT INSTALLATION NOTE8 ' i DUCT TRANSITION FROM RTU TO DUCT SIZE SHOWN ON MECH. FLOOR PLAN SHALL BE MADE BETWEEN RTU & TOP OF ROOF WITHIN CURB. SIZE OF OPENING IN ROOF DECK TO BE AS SMALL AS POSSIBLE, 6" MAX. LARGER THAN DUCT SIZE SHOWN. COORDINATE W/STRUCTURAL PLANS. INSTALL PER MANUFACTURER'S RECOMMENDATION AND INSTALLATION MANUAL. ' ALL WIRING BY ELECTRICAL CONTRACTOR. SHIM CURB AS REQUIRED TO PROVIDE HORIZONTAL INSTALLATION OF UNIT WITHIN PRESCRIBED TOLLERANCES CONTRACTOR SHALL COORDINATE LOCATION OF ROOF CURB WITH STRUCTURE PRIOR TO INSTALLATION. ROOF CURB BY AIR CONDITIONER MANUFACTURER. PROVIDE ADDITIONAL BRACING AND SUPPORT. AS REQUIRED FOR ROOF CURB INSTALLATION TO WITHSTAND WIND LOAD PER LOCAL CODES. CURB TO BE HEAVY GAUGE GALVANIZED STEEL CONSTRUCTION AS RECOMMENDED BY MANUFACTURER, ALL FASTENERS SHALL BE CORROSION PROTECTED IF EXPOSED TO OUTDOORS 9. FOR A/C UNIT ROOFCURB, PROVIDE 3/8"' THRU BOLTS WITH MIN. LENGTH AS DETERMINED BY FIELD CONDITIONS TO INSURE PROPER ATTACHMENT TO STRUCTURE. PROVIDE ANCHORING AS RECOMMENDED BY STRUCTURAL ENGINEER. 10. CLEARANCE OF UNIT TO ABOVE FINISHED ROOF SHALL COMPLY WITH LOCAL CODE REQUIREMENTS: PAR. 1511.7 FOR FLORIDA BUILDING CODE, 2001 ED. ' ECEIVED :'JUN 2 2 200Q ~:FILE COPY. BUILDING DI~:~OJ~ R [3- O0 HVAC EOUIPMENT ROOF CURB DETAIL NOT TO SCALE IN CITY OF BoYNToN BEACH, FLORIDA.. .SHEET OF PERMIT SET e DO NOT REMOVE JUL 1 9 200~ CORRECTED FILE COPY BUILDING DIVISIOIq ISSUED FOR PERMIT 06-18--04 ISSUED FOR CONSTRUCTION KAMM CONSULTING PROJECT #: 2004-0506 PROJECT MANAGER: JOE BERLIN '.i 1407 West Nexvport C&iter Deenqeld Beach, Iqonaa 334& Phone, 954,949.. 22~0 ........ ~-~O~ eng~neenng~e°hs~[~'C°m M~ea PeHa F]ofi~ Li~ ~SVOS ~ ' a · MECHANICAL DETAILS DATE: SHEET NO. M5.1 Michael W. Hanlon AR0017270 sHEET TITLE ' HNM proJect no,;04,-041~