REVIEW COMMENTS IA/ James A. Johnson Architect Suite 5 310 S.E. First Street PH. 305-243-1715 Delray Beach, FL 33483 March 14, 1989 Mr. Jim Golden Planning Department CITY OF BOYNTON BEACH 120 E. Boynton Beach Blvd. Boynton Beach, FL Re: Polydex Pharmaceuticals Dear Jim: This letter is to confirm our telephone conversation regarding the revisions in the exterior enclosure of the above-referenced project. The cost to use the Novatek system proved to be too prohibitive, so we have revised the drawings to show metal panels in lieu of the Novatek panels. We have retained the white translucent plastic panels at the upper portion of the wall. If you should have additional questions, please do not hesitate to call. Yours truly, JAJ:mj Architecture, Planning, Construction Management STAFF COMMENTS POLYDEX PHARMACEUTICALS SITE PLAN MODIFICATION Building Department: Fire Department: Engineering Department: Utilities Department: Police Department: Planning Department: Forester/Horticulturist: See attached memo See attached memo See attached memo See attached memo See attached memo See attached memo See attached memo - M E M 0 RAN DUM TO: FROM: DATE: RE: Carmen Annunziato, Planning Director Don Jaeger, Site Development - Building Department March 7, 1989 SITE PLAN MODIFICATION - POLYDEX PHARMACEUTICALS As a condition of site plan modification, the following comments should be incorporated into the related documents by the appli- cant: 1. Two handicapped parking stalls must be provided. 2. The striping for handicapped parking stalls must be four (4) feet in width and painted blue. 3~ Handicap parking signs, in conformance with State Department of Transportation standards, must be provided at each handi- cap parking stall. 4. Dumpster enclosure details must be provided. A six (6) foot high stuccoed concrete block wall is required on three (3) sides of the dumpster. 5. Curbing must be provided around all landscaped areas adjacent to parking stalls. 6. Provide dimensions for the parking area at the front of the building. 7. A legend must be provided on the landscape plan indicating height, spread and numbers for all proposed landscape materials. 8. All plans submitted for public record by a design professional, registered in the State of Florida, must be signed and sealed. 9. A recent survey of the site is required. 10. All buildings must be accessible to the handicapped. Provide spot elevations on the site plan indicating accessibility. 11. Buildings must comply with Table 400 of the Standard Build- ing Code, 1985 edition, for allowable building areas. 12. Light poles must be designed, in accordance with Chapter 12 of the Standard Building Code, to withstand 120 miles per hour windloads. 13. Chemical discharge into the sewage system must comply with the limits expressed in the City codes. The applicant's prompt compliance with the preceding comments will insure a timely permitting process. DJ:eaf cc:TRB file I --, FROM TO Jim Golden City Planner William D. Cavanaugh Fire Inspector ~OLD . SUBJECT: ._______________ _______________.___eJ1a_em_g_~_e uJ;_i_c;;_aJ_~Q__"_________.__.___________________________________J)A TE:.__;I_=_!Q_=~_~______________ 1421 Neptune Drive Per City Sub-division requirements for fire hydrants - "No portion of any building shall be over 200 feet from the fire hydrant". PLEASE REPLY TO . SIGNED REPLY DATE: SIGNED Item H F269 @ Wheeler Group Inc. 1979 THIS COPY FOR PERSON ADDRESSED TRB MEMORANDUM :<i .'l1'(! > ~,. 'I B ':I To: Jim Golden From: Bill Flushing Re: Polyde~ Pharmaceut1cals: COMMENTS: 1 k. Extruded surface curbing is not permitted. .., .... . A correct curb detail is requIred. 3. A complete lighting plan with details is requlred. 4. A drainage evaluation cr plan is required, including the follm'>1ing: . Calculations . Percolation data . Elevations . DraInage DetaIls ::. The flllSl1 11ead,er in tIle l~ight-of-wa:l lUt.1St ha"lE \... d.etail ane: the radius should be shown (30 ft.). i:;.. The side\oialk where the pavement 1S being added must be ;) 111c11es thid;. 7. A dumpster detail is required. 8. The handicap parking s~riping must be blue. A blue handicap symbol and a regulation sign is required. 0. A st)P 3ign detail is required, showing heIght and embedment 10. A parkIng bumper detail i~ required. ~1f:m:~q MEMORANDUM To: Carmen Annunziato, Planning Director~~J John A. Guidry, Director of Utilities~l From: Date: March 8, 1989 Subject: TRB Review - Polydex Pharmaceuticals - Site Plan We can approve this project, subject to the following conditions: A reduced pressure backflow preventer will be required on the water service between the meter and the building. dmt bc: Peter Mazzella MEMORANDUM TO Mr. J. Golden DATI' 08 March 1989 FILl! FltOM Lt. Dale S. Hamnack SU8JR'CT Polydex Pharmaceuticals As per our discussion at the Technical Review Board Ireeting of 7 March 1989, I am requesting the following: 1) Lighting details. 2) One Way sign and parking lot striping. 3) Review security system. 4) Do Not Enter sign on west driveway. :7~;::' fl! ~ S. HamPack DSH/lav MEMORANDUM 8 March 1989 TO: CHAIRMAN AND MEMBERS PLANNING AND ZONING BOARD FROM: CARMEN S. ANNUNZIATO, PLANNING DIRECTOR RE: polydex Pharmaceuticals Site Plan Modification Staff Comments With respect to the above, please be advised of the following: 1. A signed and sealed survey dated within six (6) months is required. 2. Removal of the proposed mechanical room from the site plan drawings should be reflected on the colored elevations. 3. An Environmental Review Permit is required for this use prior to the issuance of an Occupational License. 4. A site lighting plan is required. The plan should show the location of fixtures, typical pole detail, fixture detail, and type of energy efficient lighting. photocell activation is required. (see section entitled "Lighting" in the Engineering Department Parking Lot Specifications of Article X, Parking Lots) . 5. Future phasing or expansions will require additional Environmental Review and may require subsequent site plan modifications. L-.... J( r CARMEN S. AN NZIATO CSA/csd cc: Central File MEMORANDUM TO: Carmen Annunziato Planning Director FROM: Kevin J. Hallahan Forester/Horticulturist DATE: March 9, 1989 RE: Polydex Pharmaceuticals - Site Plan Modification 1. The applicant should provide a landscape legend designating the heights and names of landscape materials which exist. 2. The swale area along Neptune Drive should be constructed with sod and receive irrigation from the existing landscape areas. ~-J~ Kevln J. H alfcl. ~ Forester/Horticulturist KJH:ad DOC:A:POLYDEX po ~Y-()fX f/f-kRJi.A-cEatFcJt-ts EJv'V ;2EVFf5W / Cf-o f /If E P T iA)J E () R. C FTo X Jt [:/< ~ Y )J~ v;f-TEc k ) (~ 50<95Q. FT #- fit f [0 Y /.-=: E 5 f ff-.kr E / =- C"!1 t-=:J1 +CAL T !3sT +N~ {/f- BoRA- To(';: Y ~ fCGME fR.r:P^pJ~- JtN ~R. F:Pt.E po L 'if) EX ftf-Jr-/<ItA-cI5u T+cA-LS (j) 5u/? V ;: '( <: pDtJ 2. t)u){P5Tf3;:C f5)J{{&5-Uf(E j)ET>1-FL- . c~.5 }Jl:5f1lli.ELJi-R~_j3J~:f-}Jly'~~cA.DED rAl PA-RjL:r)j~ cA=L[0{ CJfi -F<91it~~----tbJ5Tt'CJr[iiici~-"3~octJJ D~~ -{ ! ~o)/Jr-L--~_~Q(A+R~D ) (!j) AAi E/V t/ fl< oN )( Ej/ f;tL 1<!3 V +I:o tv f 15 p)f:r:. / .:p5 R&G2 CA+KE D poi< rifFS C(SE ?R~oj( /(9 rffE r55rA.>{-J/cl3 uF $ &ccG{fA-TFo)/)-t- CFcc%sE ~ ,A)/{ fcA-A/ /2~&c For< [5/< 5/f0C{~D 8LS :r-/Vcol.(feR.A-r~ o \-- r/:- +0 ~ (0 5+~.J./ -c9 F 1- (() F(AI(AR~ r:r-fJrNS:poJl5 op .jAJr!3);5+f=-kA:-/';:-oJv~ vv+ LC r< f3 Q, A-t5 p -r r +0)/ A-c e /(, ,A-Al15 /J A- r ;:'$({J rx+1< r2 l~C1/<Ttf-T5:R Sf, A-ffRoVA-LS C c-o)J;A-c If.j). poR 5'f1/5cFf:rc j(Ecf2< t-ffocbf/czR0sJ C' o L/+(;tf-fr)Jk fCf-A/ /<D BE 5W(JA:rT;E[). "0'X\.;V 9 \ F.:rRf5- fR-oT~cT +<f)J/ /~ C!J I:: (..fJ1, 0 f N t::: [)J !1 C' [;'-, ~ ovf1