REVIEW COMMENTS
n ~ f"""r7""TT 7'1'-""-"'"
r"\ LL'i~ ,I" ,,-
"":...-. .,
i.\H:
J.~jG'/
l'Lf..:" ;,
........ I.
MEMORANDUM
April 27, 1987
TO: Medard Kopczynski
RE: Mega-Mini Storage Sign Code Violations/Site
Plan Approval
On Friday, April 24th, I sat down with the
representatives of Mega-Mini Storage relating to site plan
approval and sign code violations. At last Tuesday's City
Commission meeting the Commission approved Mega-Mini's site
plan modification subject to all signage coming within
compliance of the Sign Code Regulations. Upon analysis of
the situation, I believe the solution should be resolved in
this fashion:
1.
must be
to site
The south sign which is painted on the building
repainted to comply with the City's sign Code prior
plan approval.
2. The free standing sign at the corner of Congress
and S.W. 30th Avenue has been permitted improperly and said
permit must be revoked.
3.
standing
approval
Any problems with the permitting of this
sign cannot be used as leverage for site
on Mega-Mini's new site plan.
free
plan
4. The owners of the parcel where this free standing
sign is located must seek a permit pursuant to City Code.
If proper modifications are made to the sign content, this
sign may be permitted under Section 21-16(a).
In short, Mega-Mini' s new site plan must be approved
once the painted sign on the building's south wall is made
to comply with City Codes. The free standing sign at the
corner of Congress and S.W. 30th Avenue is an entirely
independent matter which is to be resolved between the legal
owners of that particular parcel and the City. The City
must proceed through the Code Enforcement Board if the free
standing sign is not permitted under th~ove cited
provision of the Code. ~
~~~.-A -- _
Raymond A. Rea
City Attorney
cc: Carmen Annunziato
Peter Cheney
..;'M
STAFF COMMENTS
MEGA-MINI SELF STORAGE
SITE PLAN MODIFICATION
Building Department:
Engineering Department:
Fire Department:
Forester/Horticulturist:
See attached memo.
See attached memo.
See attached memo.
See attached memo.
Mf:MORANDUM
RTIC'1f"7''t{!'71.....\
i r. 1 ~ 1.' .', ,if
.Jt>-,J ,.i:_.l."L ~L.",":.....J'
TO
Carmen S. Annunziato
Planning Director
D"T_
March 5,
r.1'AR ;) 19!1i
PUNN11~G DU-'r.
F'1t..
'OOM
Kevin J. Hallahan
Forester/Horticulturist
~U.J.eT
Mega Mini Self Storage
site Plan Modification
The following is in reference to the submitted landscape plan
for the above project:
1. The type of sod used should be specified.
!tt-- :~....j-/A /h ~
K vin J. allahan
KJH:ad
MEMORANDUM
RECEIVED
'0
Carmen Annunziato
Planning Director
OATE:
March 3, 198"RAAR 4 1961
PLANNING DEPT.
Site Plan Modification.
Mega-Mini Self Storage
FILE:
FROM
Don Jaeger
Chief Inspector
9U9Jl!CT
As a condition of site plan approval, the following comments should be
incorporated into the related documents by the applicant:
1. Classify the proposed type of construction for the structures in
conformance with Section 601.1.1 of the Standard Building Code (SBC).
2. The allowable building area must comply with Table 400 of the
Standard Building Code for the type of construction and proposed
occupancy. Indicate on the site plan the total square foot areas
for each proposed structure. Any structure with a greater square
foot area than allowed by Chapter Four, Standard Building Code
must be separated by four hour walls.
3. Table 308.2 of the Countywide Amendments to the Standard Building
Code requires 7 handicapped parking spaces when 216 parking spaces
are provided.
4. Show the setback from the property line along the Lake Worth
Drainage District L-28 Canal to the proposed structure.
5. Section 1103.2 of the Countywide Amendments to the Standard Building
Code allow an exception to the requirement for a side swinging egress
door providing three conditions are met. The proposed condition in
these structures does not meet the requirement of a maximum of 200
square feet per tenant space. Exit doors must be provided from all
tenant spaces.
6. The minimum length of a parallel parking stall must be 25 feet.
7. Handicapped accessibility should be provided for these units in
compliance with the State Handicapped Law. The plans indicate a
step up from the parking area of 1.5 inches for each unit.
State law requires that this be reduced to a maximum of 0.5 inches.
8. Show details on the type of proposed exterior lighting.
9. Parking areas must be striped in accordance with Boynton Beach Codes
and curbs must be installed adjacent to all landscaped areas.
The following information is for applicant's information:
In order to facilitate the building permit review process, the following
information should be provided, in duplicate, at the time of plans
submittal:
1. Copies of the South Florida Water Management District approval for
the site.
2. Soil tests.
3. Complete sets of the construction documents and plans, signed and
sealed by the relevant design professionals.
NOTE:
work.
Separate permits are required for Paving, Drainage, and Excavation
Memo to Carmen Annunziato
RE: Mega-Mini Self Storage
March 3, 1987
Page Two
The applicant's prompt compliance with the preceding comments will insure