CORRESPONDENCE 1489 W. PALMETTO PARI< ROAD SUITE 501 BOCA RATON, Fl 33486 TELEPHONE: (561) 392-2442 FACSIMilE: (561) 392-2265 LICENSE: #AJ'COD1758 ARCHITECTURE & INTERIOR DESIGN DONAHUE & company, inc December 31, 1998 Mr. Dan DeCarlo, Assistant Planner Department of Development City of Boynton Beach 100 East Boynton Beach Blvd. Boynton Beach, Florida 33425-0310 Re: Boynton Commerce Center Dear Mr. DeCarlo Pursuant to our recent meetings on the above subject, please find attached our revised submission for consideration to the proposed Site Plan Modifications as discussed, and having incorporated the comments of the TRC review. The intent of this minor change is to move around the square footages of various buildings, so as to increase the square footage of Building "A" from the previous total of 71,134 sf by a total of8,199 sf To a new total of79,533 sf Thishasbeen accomplished by removing the "chamfer" edge of the building from the previous configuration. In order to address a "no net change" in the project balances, we have made the following adjustments in the future buildings as follows: · Building "B" reduced from previous 83,305 sfby 4,200 sf to a new total of 79, 105 sf · Building "c" reduced from previous 74,084 sfby 4,199 sf to a new total of69,885 sf Attached to this letter is a summary sheet of total development areas for your perusal. Our proposed revision does not impact the current parking levels, nor landscapittg requirements of the project. Furthermore, our site remains the same, with some minor adjustments of landscaping and parking locations as shown. Other considerations notwithstanding, our site will accommodate such an increase with no additional encumbrances to those previously satisfied. Included in this submission are ten (10) copies those plans and exhibits as required, along with the requisite fee. Also, for your review, I have included a letter of authorization by the owner, directing this effort to be handled on his behalf by Donahue & Company. Thank you for your time and cooperation in this effort. Should you have any further questions of clarifications, please do not hesitate to contact me directly. Sincerely, DE & crJMPANY, INe. Ken all J. Flem~ 7!;c~~ Director of Architecture Attach. NEW Dp'-IELOPMENT DATA OPERATIONS CENTER ~' 30% Office 20% Manufacturing 50% Warehouse TOTALS Handicap Required Handicap Provided Sqft Spaces 23,859.9 80 15,906.6 32 39,766.5 50 19,533 161 151-200 = 6 8 OPERATIONS CENTER 'B' 30% Office 20% Manufacturing 50% Warehouse TOTALS Handicap Required Handicap Provided Sqfl Spaces 23,731.5 79 15,821.0 32 39,552.5 49 79,105 160 151-200=6 8 OPERA TIONS CENTER 'C' 30% Office 20% Manufacturing 50% Warehouse TOTALS Handicap Required Handicap Provided Sqft Spaces 20,965.5 70 13,977.0 28 34,942.5 44 69,885 142 101-150 = 5 8 EXISTING DEVELOPMENT DATA Sqft Spaces 81,350.0 170 67,150.0 169 60,000.0 169 35,715 72 244,215 580 Building 1900 Building 2000 Building 2100 Parcel 3G TOTALS TOTAL DEVELOPMENT DATA (1 per 300 ,sqft) (1 per 500 sqft) (1 per 800 sqfl) (1 per 300 sqft) (1 per 500 sqfl) (1 per 800 sqft) (1 per 300 sqft) (1 per 500 sqft) (1 per 800 sqft) (existing) (existing) (existing) (1 per 500 sqft) Total New Building Sqfl 228,523 Total New Parking Spaces Required 463 Total New Parking Spaces Provided 556 Total New Handicap Spaces Required 501-1000 11.12 (2% of Total) Total New Handicap Spaces Provided 24 Total Existing Building Sqfl 244,215 Total Existing Parking Spaces 580 Total Existing Parking Spaces Lost (86) DEVELOPMENT TOTALS 472,738 957 NEW [ OPERATIONS CENTER 'A' 30% Office 20% Manufacturing 50% Warehouse TOTALS Handicap Required Handicap Provided OPERATIONS CENTER 'B' 30% Office 20% Manufacturing 50% Warehouse TOTALS Handicap Required Handicap Provided OPERA TlONS CENTER 'C' 30% Office 20% Manufacturing 50% Warehouse TOTALS Handicap Required Handicap Provided 'ELOPMENT DATA Sqft Spaces 23,859.9 80 15,906.6 32 39,766.5 50 79,533 161 151-200 = 6 8 Sqft Spaces 23,731.5 79 15,821.0 32 39,552.5 49 79,105 160 151-200=6 8 Sqft Spaces 20,965.5 70 13,977.0 28 34,942.5 44 69,885 142 101-150=5 8 EXISTING DEVELOPMENT DATA Sqft Spaces 81,350.0 170 67,150.0 169 60,000.0 169 35,715 72 244,215 580 TOTAL DEVELOPMENT DATA Total New Building Sqft ~t3 Total New Parking Spaces Required Total New Parking Spaces Provided Total New Handicap Spaces Required 501-1000 Total New Handicap Spaces Provided Total Existing BUilding Sqft Total Existing Parking Spaces Total Existing Parking Spaces Lost Building 1900 Building 2000 Building 2100 Parcel 3G TOTALS DEVELOPMENT TOTALS (1 per 300 sqft) (1 per 500 sqft) (1 per 800 sqft) (1 per 300 sqft) (1 per 500 sqft) (1 per 800 sqft) (1 per 300 sqft) (1 per 500 sqft) (1 per 800 sqft) (existing) (existing) (existing) (1 per 500 sqft) F$ B 3>qq ';If ~ rIOOs. "11 \'".34~f \ ess 4 '2<llO sJ. ~O-<M ~;eu.s B3,~ * le'!.s 4\ qq '3~ ~ ~I~U~ 74- 004 ~S- \'\0 ~(2., 11\ 0 clt-O"l-\-ye- 463 556 11.12 24 580 (86) 957 ~ (2% of Total) VlO ~~ V\o c4~ OQc-15-9S 11:3SA OONAH~ & COMPANY 561 39;az265 P.02 !489 W. Pl\tM! i 10 ',-.r..K r~(:;At:' ~UI1L ~{ll lKlC^ IN',lC.'~. i"l 3:l4B~ Ii', Fr'l-lONE; (.:.~ 1 )'W;( 1'4'\'1' FAC:';IMiLt: (Y.lI) 'W'i-~':/({, IIC:F.l\iSE #At'COI)1 j~ . DONAHUE 8..: c6mpan~'"" ."-.r(:::HITECll.l'<'1 ~ I~ 111~h.X~ D?SlCN December 14, 1998 Mr. Dan DeCarlo, Assistant Planner Department of Development City of Boynton Beach 100 East Boynton Beach Blvd. Boynton Bcach, Florida 33425-0310 Re; BoyntoD Commerce Center List of Proposed Revisions Dear Mr DeCarlo Pur..uant to your recent request for clarifications to our proposed Site Plan Modifications, and several remarks posed in our 1" Review TRC comments, we respectfully otler the following clarification outlining the scope and extent of those modifications The principal revision proposed is the increase in gross square footage of Building "A" from its current size of 74,084 S.F. to a new proposed size of 79,533 s.f This has been accomplished by "squaring off" the previOlls "stepped comers" of the building, thus filling in the building envelope within the overall size pararnelers. Also, the building, roadway and utility easement previously rotated at a (10 degree angle) has been slightly reduced (to a rotation of five degretl angle) achieve the overall gross building footage to its proposed 79,533 SF The inlent ofthis minor challllC is to increase the square footage of Building "A" to a higher allowable building tbotprint. Parkinll has been in several isolated instances relocated, but not compromised. We still maintain an excess of open space and parking in salisfacti\)n of the overall project requirements. Our proposed revision does not impact the current parking levels, nor landscaping requirements of the projecl. Furthermore, our site remains the same, with some minor adjustments of landscaping and parki~g locatIons as shown. We do not intcnd (0 modify the other Building "B" or OQc-15-9S 11:3BA DONAHUE & COMPANY 56139~265 P.03 Building "C" of the project alIbis lime. Also, revisions to Dumpster location and orientation are in keeping with those comments recently reflected by Public Works officials. Other considerations notwithstanding, our site will accommodate such an increase witl1 no additional encumbrances to those previou~ly satisfied. Thank you for your time and cooperation in this cffort Should you have any further questions of clarifications, please do not hesitate to contact me directly. Sincerely, DONAHl;E & COMPANY,INc' Kendall J Fleming, AlA, NCARB Director of Architecture Attadl