Loading...
CERT OF OCCUCITY OF BOYNTON BEACH P.O. BOX 310 BOYNTON BEACH FL 33425 CERTIFICATE OF OCCUPANCY PERMANENT Issue Date ...... Parcel Number ..... Property Address Subdivision Name . . . Legal Description Property Zoning .... Owner ......... Contractor ...... ii/05/0i 08-43-45-18-2i-003-0020 1849 MAGLIA_NO DR BOYNTON BEACH FL 33436 PLANNED ZONED DISTRICT CONTINENTAL HOMES Application number Description of Work Construction type Occupancy type .... Flood Zone ...... Special conditions Approved 01-00002729 000 000 SINGLE FAMILY-BLANKET TYPE VI/UNPROTECTED RESIDENTIAL B FLOOD ZONE/MIN FLOODING FINISH FLOOR ELEV 14.43' AS IDENTIFIED ON THE FLOOD ELEVATION CERTIFICATE Buildi~ Official VOID UNLESS SIGNED BY BUILDING OFFICIAL Adv htage Pest Related Services Pre-Construction Termite Treatment Contract Advantage is a full service company offering pest control, lawn & ornamental spraying and fertilization, and termite control. For more information, please call (800) 698-7998. Specific terms & conditions regarding this contract appear on the back of this page. Should holder have any questions with reference to this contract, please contact our office at the number or address noted below. This contract is transferable and is for the primary structure noted below. It does not include, unless specified in writing, fences, detached structures, decks and additional construction provided after the date contract is issued. Reference to termites applies to subterranean termites, including Formosan termites. This contract does not provide for protection of any other wood destroying organism, insect or pest. General Conditions & Treatment - Repair Warranty Company agrees to warranty the structure for an initial period of eighteen (18) months from the date of the initial treatment. If termite infestation occurs at any time during this period the company will inspect property and provide remedial treatment(s), spot or full, with a liquid termiticide as required to eliminate or control termites. Should termite damage be noted through inspection, company or a subcontractor(s) chosen or approved by company, will repair damage caused by termites at no cost to property owner. For an annual fee specified below, holder may extend this warranty / contract for a maximum period of four (4) additional years, as specified in paragraph two (2) of terms and conditions noted on the back of this page. Residential Treatment Information The treatments provided are for preventive purposes and were requested by the contractor or builder noted below. Pre-construction termite treatments are applied as defined by EPA approved pesticide labels. Supplemental treatment(s) (patio, entryway, abutting foundation, etc.) were provided subsequent to the initial treatment date, as notified of readiness by builder. The cost of this treatment has been billed to the builder or a sub-contractor of the builder. VerticalTreatment Date: 10-17-2001 ~ Cert. !ss,_,e D~te: ! 0/16/200! _n,_,i!der: Continental Homes Initial Date: Property Address: Treatment Cost: Renewal Fee: Treatment Area: Product(s): 08/08/2001 Subdivision: Borgata 1849 Magliano Drive Boynton Beach, FL 33436 Billed to Contractor $110.00 2096 Chlorpyrifos 0.5% Lot/Block: Lot 2/Block 3 This mpany seal and certificate issua._~_~ Th~t~.~..t3~ated through verbal request as P~tte~~Aami~ll~tive Code section 105.2K. Thel~l~eat~l~lied~_~result of building code or fina~inst~irem ~. /  4439 Authorized 7ggn~L.~pany License No. Advantage Pest Related Services, Inc. 2800 N.W. 22nd Terrace · Pompano Beach, FL 33069 1-800-698-7998 www. advantagepest.com FORM 600A-97 " FLORIDA' ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ~/~ c~. Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name; ~30 R (:~:z ~-[' 1'3r -' HA-308. Builder: SAME Address: UNIT. 1803 Permitting Office: City, State: PALM BEACH CO., FL Permit Number:. ' owner: CONTINENTAL HOMES Jurisdiction Number: l Climate Zone: South 2. Sins]¢ t'~nil)' or multi-~ily 3. ~umb~rofm~it,,ifm~fl.fa~17 4. Numar of Be~oonu 5. Is ~s a x~.rst cas~? 6. Conditi0~cd floor ~ea (~) b. Clt~. doub~ c. Tinffoth,r SC/$HGC, d. Tinvmh:r SCiSEGC - doubl, 8. Floor a. Slab-On-Grade Edge b. c. N/A 9. Wall a. Concrete, Iht In,~ Exterior b. Frame, Wood, c. *. 10. C~[lJng a. Under Attic b. c. l I. Ducts fmnily _ l 3 Yes 668 A: 0.0 fi' 43.5 fl: 239.9 ~: 0.0 R: R',O.O, 190.9(p) ft __ R=4.2, 1144.9 P--.11.0, 324.1 ft: R.=lg.0, 1793.0 It* a. Sup: Une, Ret: Uno. Al-/: Garage Sup. Re6.0, $0.0 £t -- b.N.'A -- ]5, 12. Cooling systems a. Central Unit *; b.N,A c. NrA 13. Hcating,yst¢ms a. Electrlc Strip b. N/A e. N/A 14." .Hot wa£er systems a. Electric b. N/A COBgel'v.~.ti CCi cred(t$ t'~R-He~t rccovcry~ Solar O~-DedJcated beat pmnp) credits (Cf-Ceiling fan, CV-~o~s ventilation, ~-~'~ole house fmh PT-Progr~ablc ~em~estat, ~-Auic rad/m~t bm'icc, ~-C-MuIdzonc coolin~ ~-~-Mult~one bestir) Cap: 40.0 i~tw~ SEER.: 12,00 Cap: 40.0 Id~tu/hr COP: 1.00 Cap: 50.0 ga[logs EF: 0.88 Glass/Floor Area: 0.17 Total as-built Total base I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code, PREPARED BY: C.E.M.-(561)686-5616 t l hereby certify that this bulJdjr/~ as designed, is in ' compliance with the FlorM~ ~gy Cod%, DO, WNEPJAGENT: q/~ points: 24289.00 points: 25654.00 EnergyGauge® (Version: FLRCNA-200) PASS 'i Review of the plans and specifications covered by this ~ calculation indicates compliance wit, il the Florida Energy Code. Before construction is completed, this building will be insect,} compl[a, nce with :' Frorida ~=~.~~0~ ~~ S~tutes. BUILDING O DATE: CITY OF BoYNTON BEACH ENGINEERING DEPARTMENT DRAINAGE CERTIFICATE OF COMPLIANCE PERMIT NUMBER LEGAL DESCRIPTION: Lot 2, Block 3, "MELEAR, P.U.D.", according to the Plat thereof, as recorded in Plat Book 86, Pages 145 through 150 of the Public Records of Palm Beach County, Florida. CERTIFICATION: Based upon field review under my responsible charge and review of the final survey as required by the Engineering Department, it is my professional opinion that the lot grading has been constructed in substantial accordance with the approved drainage plan for the subdivision and/or the drainage control points referenced on the individual lot site plan or construction layout survey on file with the Engineering Department. Thomas R. Palbicke Professional's Name Signature 5061, State of Florida Registration Number October 17, 2001 As of this Date HAGER, PALBICKE & ASSOC., INC. 3850 N.W. Boca Raton Blvd. Suite # 3, Boca Raton, Florida 33431 Address Phone: (561) 395-3600 Facsimile: (561) 395-2237 Phone SEAL \\HwaT\HWA7\HWAproj\DOCfiles\M\Melear\aaDrainCert.doc DUNKELBERGER ENGINEERING & TESTING, INC. To: Attn: LOT SUITABILITY STATEMENT Continental Homes of Florida, Inc. 8000 Governor's Square Boulevard Suite 101 Miami Lakes, Florida 33016 Mr. Rafael Roca Report Date: Project Name: Project No.: Lot Number: Block Number: August 8, 2001 Borgata, Boynton Beach, Florida 99-20-1492 2 3 DENSITY TEST RESUL TS Area Tested: Remarks: Building Area Minimum Compaction Requirement = 95% (ASTM D- 1557) Laboratory Proctor Field Tests Location of Test Depth Maximum Optimum Dry % % (In.) Density Moisture Density Moisture Compaction (pcf) (%) (pcf) 9 feet north and 14 feet east of 12 107.5 12.1 106.9 4.1 99.4 southwest building corner 12 feet south and 11 feet west of 12 107.5 12.1 108.2 3.6 100+ northeast building corner SUMMARY STATEMENT Based on the results of soil borings previously drilled for the project and the field density test results, we believe the building area soils at the referenced location(s) have been satisfactorily prepared and are suitable to support conventional shallow foundations and a slab-on-grade designed for a net soil contact pressure of 3,000 pounds per square foot (psf) and are in conformance with the multiple lot testing requirements of the City of Boynton Beach Amendments to Chapter 18 of the Standard Building Code (Chapter 18, Section 1804). oO0 Very truly yours, DUNKELBERGER ENGINEERING & TESTING, INC. 'Thomas J. Tepper, D.E. Principal Engineer FL Registration No. 2745 1492ffs.2-3 cc: Addressee (1), Continental Homes, Attn: Ms. Robyn Pedretti (2), Site (2) 6833 Vista Parkway North, West Palm Beach, Florida 33411-2702 * Phone: (561) 689-4299 · Fax: (561) 689-5955