Loading...
LEGAL APPROVAL ~~ c:.... DEPARTMENT OF DEVELOPMENT Division of Planning and Zoning Building Planning & Zoning Engineering Occupational License Community Redevelopment January 7, 2000 Tom Kasischke Seminole Bay Land Company 3923 Lake Worth Road, Suite 210 Lake Worth, Florida 33461 Re: File No.: Location: High Ridge Properties MSPM 99-005 2900 High Ridge Road Dear Mr. Kasischke: Enclosed is the City of Boynton Beach Development Order for major site plan modification granted on December 7, 1999. To continue this project through the development process, please submit to this office a rectified plan (a site plan revised to incorporate all applicable conditions of approval). The rectified plan must be signed-off by all TRC members prior to submitting for building permits. Should you have any questions regarding this matter, please feel free to contact this office at (561) 742-6260. Sincerely, 7~U2. Michael W. Rumpf Director of Planning & Zoning MWR/nl 1\SHRDAT A\PlanningISHAREDI\VP\PROJECTSIHIGH RIDGE PROPERTIES. MSPM'Development Order letter. doc America's Gateway to the Gulfstream 100 East Boynton Beach Blvd.. P.O. Box 310 Boynton Beach. Florida 33425-0310 Phone: (561) 375-6260 FAX: (561) 375-6259 DEVELOPMFJ-JT ORDER OF THE CITY COMMIS~N OF THE C. / OF BOYNTON BEACH, FLORIL PROJECT NAME: High Ridge Properties APPLICANT'S AGENT: . Tom Kasischke - Seminole Bay Land Company APPLICANT'S ADDRESS: 3923 Lake Worth Road, Suite 210 DATE OF HEARING BEFORE CITY COMMISSION: December 7,1999 TYPE OF RELIEF SOUGHT: Major Site Plan Modification LOCATION OF PROPERTY:2900 High Ridge Road DRAWING(S): SEE EXHIBIT "B" ATTACHED HERETO. X THIS MATTER came before the City Commission of the City of Boynton Beach, Florida appearing on the Consent Agenda on the date above. The City Commission hereby adopts the findings and recommendation of the Planning and Development Board, which Board found as follows: OR THIS MATTER came on to be heard before the City Commissjon of the City of Boynton Beach, Florida on the date of hearing stated above. The City Commission having considered the relief sought by the applicant and heard testimony from the applicant, members of city administrative staff and the public finds as follows: 1. Application for the relief sought was made by the Applicant in a manner consistent with the requirements of the City's Land Development Regulations. 2. The Applicant ~HAS HAS NOT established by substantial competent evidence a basis for the relief requested. 3. The conditions for development requested by the Applicant, administrative staff, or suggested by the public and supported by substantial competent evidence are as set forth on Exhibit "Cft with notation "Includedft. 4. The Applicant's application for relief is hereby ~ GRANTED subject to the conditions referenced in paragraph 3 hereof. DENIED 5. This Order shall take effect immediately upon issuance by the City Clerk. 6. All further development on the property shall be made in accordance with the terms and conditions of this order. >' ,\ \ \1\11 II 1/11/1 $-~<~ O'fNTOI\fII//,f~ ~ <<~ ......... -L'o ~ , ..- oOt::l;,.. Q'" Z ~ 0 "o~r- . "'~" ~ ~ ..:::: ...-, ~ <,-,_e.. ..,. ~ ~ Y4. ~ >- ,~ '0, 0 ~ DATED: /~h/~~ , ~~ ~/1/ ~ : ~ C j J: ~ City Clerk ~ " 1920 I ::: JISHRDATAIPlanningISHAREDIWl'lPROJECTS\HIGH RIDGE PROPERTIES. MSPMIOevelop Ord. CC 12~7-99.dOc ~...... .../,f$ ~ ............ ~ %//, }:'LO~\O~\\#' 1'/1/IIt 1/111 H\\\\\\ 7. Other p~ l/ EXHIBIT "C" Conditions Of Approval Project name: HIGH RIDGE PROPERTIES File number: MSPM 99-005 Reference: 3rd Review. Maior Site Plan Modification. File # 99-005 with a November 9. 1999 Planning and Zoning Deoartment date stamo marking DEPARTMENTS INCLUDE REJECT PUBLIC WORKS Comments: None X UTILITIES Comments: 1. All utilities easements shall be shown on the rectified landscaping drawings so that we may determine which trees may interfere with X utilities. In general, palm trees will be the only tree species allowed within utility easements. Canopy trees may be planted outside of the easement so that roots and branches will not impact those utilities within . the easement in the foreseeable future. LDR Sec. 7.5-18.1 gives public utilities the authority to remove any trees that interfere with utility services, either in utility easements or public rights-of-way. 2. Dept. of Health permits may be required for the water and sewer systems X serving this project. (Sec. 26-12). 3. Fire flow calculations will be required demonstrating the City Code X requirement of 1500 g.p.m. as stated in LDR chap. 6, Art. IV, Sec. 16, or the requirement imposed by insurance underwriters, whichever IS greater. (see Sec. 26-16(a)). Please submit these calculations with your Health Department permit submittal. 4. Water and sewer lines to be owned and operated by the City shall be X included within utility easements. Please show all proposed easements on the engineering drawings, using a minimum width of 12 feet. The easements shall be dedicated via separate instrument to the City as stated in Sec. 26-33(a) of the Code. 5. This office will not require surety for installation of the water and sewer X utilities, on condition that the systems be fully completed, and given to the City before the first permanent meter is set. Note that setting of a permanent water meter is a prerequisite to obtaining the certificate of occupancy. 6. LDR Chap. 6, Article IV, Sec. 16 requires that all points on each X building will be within 200 feet of an existing or proposed fire hydrant. Please demonstrate that the plan meets this condition, by showing all hydrants. 7. A building permit for this project shall not be issued until this office has X PaJe 2 File Name: HIGH RIDGE PROPERTIES File No.: MSPM 99-005 DEPARTMENTS INCLUDE REJECT approved the plans for the water and/or sewer improvements required to serve the project. (Sec. 26-15) 8. The waste stream from the manufacturing process must meet the City's X pretreatment requirements. A sampling point must be provided to allow monitoring of this waste stream. (Sec. 26-143, 26-147 . FIRE Comments: 9. A water distribution plan was not provided showing locations of X hydrants, fire department connections or main sizes as required by LDR 6-16. No part of the building may be more than 200 feet from a hydrant. LDR 6-16. This plan is not ready to go forward without these requirements. A fire flow test will be required. POLICE Comments: None X ENGINEERING DIVISION Comments: 10. Add a general note to the paving & drainage plans that all striping, X signage and markings shall conform to City Standard Drawing B-9800 1. Add another note that the drainage system shall conform to City Standard Drawing B-91007 and show the detail on the plans. 11. All striping, signage and markings shall be incorporated in the paving X and drainage plans for inspection purposes. 12. On the civil plans, specify header curb in lieu of type "D" curb within X both rights of ways, and "D" curb around all grassed islands. 13. Submit an acceptable paving/drainage plan with all required dimensions X and details prior to continuing in review process. 14. Provide an accessible path from the public sidewalk to new building in X conformance with the Florida Accessibility Code. 15. On the drainage plan, correct the invert callout at structure A-4 to read, X 16.0 (N.W). 16. Clarify west invert call on structure A-I. X 17. Provide a sump for all truck well inlets to reduce contaminants and X pollutants from entering exfiltration trenches. Page 3 File Name: HIGH RIDGE PROPERTIES File No.: MSPM 99-005 DEPARTMENTS INCLUDE REJECT BUILDING DIVISION Comments: 18. Add to the buildings that are depicted on the site plan drawing a labeled X symbol that represents the location of the handicap accessible entrance door to each tenant space of both buildings. Show and label the same doors on the floor plan drawing. The door, landing and threshold shall comply with the regulations specified in the Florida Accessibility Code for Building Construction. 19. The finish floor elevation that the design professional identified on the X site plan drawing does not match the elevation that is identified on the civil plans. Amend the drawings accordingly. Identify on the floor plan within the footprint of the new building the finish floor elevation that the design professional has established for the structure. 20. Considering that detail drawings of the building signage were not X provided and the location of the signage was not shown on the building elevation view drawings, place the following note on the drawing that illustrates the elevation views of the building: "Building signage is not approved for this project. Separate site plan review and approval is required for building signage." 21. On the site plan drawing, identify the symbol that represents the X property line of the subject property. 22. At time of permit review, submit for review two (2) sets of signed and X sealed working drawings depicting the proposed construction. 23. At time of permit review, attach a current survey of the subject property X to both sets of permit documents. 24. At time of permit review, specify, in tabular form, on the site plan and/or floor plan drawing the proposed use of the facility, type of construction and occupancy classification including indicating whether the new building will have a fire sprinkler system. The design of the building, building area, occupancy classification and type of construction shall comply with the specifications identified in the 1997 edition of the Standard Building Code including the City of Boynton Beach amendments to the Standard Building Code. Place a note on the site plan and/or the floor plan drawing indicating that the building is designed in compliance with the 1997 edition of the Standard Building Code including the City of Boynton Beach amendments to the Standard Building Code. The working drawings submitted for permits shall comply with the codes specified in Chapter 20 of the Land Development Regulations Page 4 File Name: HIGH RIDGE PROPERTIES File No.: MSPM 99-005 DEPARTMENTS INCLUDE REJECT 25. The permit fee, water and sewer facility fees, Fire and Life Safety fees, X County fees and State fees for the subject project will be determined at time of permit review 26. Permits are required to construct the improvements thatare shown on the X approved site plan. Permit application forms are available in the Building Division of the Development Department. A permit submittal checklist is available in the Building Division. The list identifies the basic documents that the Plans Analyst checks for when an applicant submits for permit review. PARKS AND RECREATION Comments: None X FORESTER/ENVIRONMENT ALIST . Comments: None X PLANNING AND ZONING Comments: 27. Sign and seal all drawings prior to building permit submittal X 28. On the landscape plans provide the following information: Ch.7.5, X Art.Il, Sec.5 - Specify source of irrigation system. 29. On the Architecture plans provide the following information: ChA X Sec.7 Par.D - Tabular information including paint colors (mfg. and code) and construction materials. 30. Site data indicates 1,000 square feet of office for each of the 3 bays, X whereas sheet A-2 (Building Plan) indicates 1,200 square feet for each bay. Correct this internal inconsistency and adjust parking calculations accordingly. 31. Parking methodology does not include office space for existing and X proposed portions of project. Revise to include breakdown for both office and manufacturing space and employee data may be used where known; document accordingly. 32. Plans must be rectified, and approved by TRC, prior to submittal for X building permits. 33. Provide 18 foot parking spaces with wheel stops adjacent to loading area X to the south. . P<:ge 5 File Name: HIGH RIDGE PROPERTIES File No.: MSPM 99-005 DEPARTMENTS INCLUDE REJECT 34. Provide height and color of truck well wall. Color should match X building. 35. Provide color for dumpster enclosure to match building color. X 36. Handicapped parking space detail shown on sheet SP-2 is not to scale; X revise accordingly. 37. Relocate tree adjacent to dumpster or replace with a smaller tree or X shrubs. ADDITIONAL PLANNING AND DEVELOPMENT BOARD CONDITIONS Comments: None X ADDITIONAL CITY COMMISSION CONDITIONS . 38. W be d~t(itrfHinca.;.be ~ J:\SHRDA T AIPlANNINGISHAREOIWP\PROJECTSIHIGH RIDGE PROPERTtES - MSPM\COND OF APPROV At CC 12-7-99,DOC