Loading...
REVIEW COMMENTS 7.A.1 GEV AS NORTH AMERICAN HEADQUARTERS NEW SITE PLAN _______~__________. _" ~__ __0._--' --- ----------.--...-.-- ----_._---------------~ ~- DEVELOPMENT DEPARTMENT MEMORANDUM NO PZ 99-201 SITE PLAN REVIEW STAFF REPORT FOR PLANNING AND DEVELOPMENT BOARD AND CITY COMMISSION August 24, 1999 DESCRIPTION OF PROJECT Project Name Property Owner" Applicant/Agent: location File No. land Use Plan Designation Zoning Designation Type of Use Number of Rooms Square Footage Surrounding land uses and Zoning District: Existing Site Characteristics Gevas North American Headquarters MFT Development, Inc. G T Investment Group I Pierce Architectural Group Southwest corner of the High Ridge Road and Park Ridge Boulevard intersection (Quantum Park PID, Lot 51 D) NWSP 99-017 Industrial (I) Planned Industrial Development, (PI D) Assembly of packaging machines and ancillary office and warehouse (Use approval granted on July 20, 1999) N/A Site Area. 52,678 square feet (1 21 acres) Building Area 10,022 square feet (see Exhibit "A" -location map) North - Park Ridge Boulevard and farther north vacant lot 56, zoned PID South - lot 51A, used for parking for Curt Joa (located on lot 302 in adjacent M 1 district) East - High Ridge Road and farther east developed lot 73A, zoned PID West - Vacant lot 50A, zoned PID The subject property is vacant and consists of 1 21 acres The site is predominately vegetated with a variety of weeds, grasses and exotic \ Page 2 Memorandum No. PZ 99-201 Quantum Park Lot 51 D (GEVAS) nuisance tree and shrub species The site has been cleared, filled and repeatedly disturbed by off-road vehicles According to an environmental assessment prepared in June, 1999 by Environmental Services, inc., one endangered Large Flowered Rosemary shrub and one Gopher Tortoise burrow has been located on site Therefore, the applicant must obtain a permit from the State of Florida to relocate both species to the satisfaction of the appropriate state agency The necessary permits and relocation must occur prior the issuance of building permits To the north of the site along the Park Ridge Boulevard right-of-way, is a row of five street trees and an 18 foot wide maintained grass area which provides some screening for the adjacent uses There is no other significant vegetation on the site Proposed Development: The developer is proposing construction of a 10,022 square foot, one story building, where the assembly of automated packaging machines will be conducted, and related parking (see Exhibit "B" - proposed site plan) Concurrency. a. Traffic - A traffic statement for the project was prepared by Pinder Troutman Consulting, Inc. Preliminary analysis indicates that this project will comply with the county's traffic performance standards as it is related to the 63,752 maximum trips permitted in the Quantum Park development. This facility will generate 67 daily trips, leaving 40,000+ trips for future development. Staff has received confirmation from the Palm Beach County Traffic division of traffic standards compliance b. Drainage - Conceptual drainage information was provided for the city's review The city's concurrency ordinance requires drainage certification at time of site plan approval The Engineering Division is recommending that the review of specific drainage solutions be deferred to time of permit review, when the necessary engineering documents are required It should be noted that this site is serviced by master drainage facilities managed by the Quantum Community Development District (QCDD) Board of Commissioners Approval to connect to and use district facilities requires approval from the QCDD through their established permit process Driveways Proposed on-site traffic circulation consists of a loop drive with one twenty seven (27) foot wide drive aisle access point on High Ridge Road reducing to a twenty four (24) foot wide drive aisle access point on Park Ridge Road The proposed twenty seven (27) foot wide vehicular use area will provide areas containing the standard (9' x 16') and (9' x 18') parking spaces Parking Facility There are 26 parking spaces proposed, including two (2) spaces designated as handicapped accessible The parking plan will meet the city's Land Development Regulations, Chapter 2 - Zoning and ADA requirements for this use, and provides no surplus spaces Regulations for the Planned Industrial Development zoning district "2 Page 3 Memorandum No PZ 99-201 Quantum Park Lot 51 D (GEVAS) require that parking requirements be based on number of employees, however, as employment information is unknown at this time, minimum required parking spaces were determined using standard code requirements for each specific use The parking requirements are one (1) space for every 300 square feet of office space, and one (1) space for every 500 square feet of warehouse space Landscaping The landscaping of the site will fully meet code requirements when staff comments are incorporated Special attention will be given to preserving the existing right-of-way landscape feature to the north of the lot, which consists of five (5) right-of-way street trees. Building and Site Regulations Building and site regulations will fully meet code requirements when staff comments are incorporated into the permit drawings Community Design Plan The proposed building facade, as viewed from either right-of-way, has been designed to be architecturally compatible to this predominately industrial use area. The new structure will receive surface treatments and colors of yellow, light gray and white cementitious finished walls accented with white moldings and window trim The proposed building is distinctive, yet complements the surrounding development. Lastly prior to issuance of permits, the site plan must be approved by the Quantum Park design review committee Signage A proposed signage detail was submitted as part of this site plan review The approved Quantum Park signage plan allows one monument sign, per parcel, with a maximum sign dimension of 7 feet high by 14 feet wide, and 64 square feet of sign face and/or a wall sign with the square footage equal to 1 5 times the linear length of the applicable wall The submitted site plan utilizes one wall sign style proposed at two different building entry points Each wall sign consists of 5 - six (6) square foot letters combined to providing 30 square foot sign, for a total of 60 square feet. In the future, if a site sign is desired, the sign must conform to the established sign program for the Quantum Park PID RECOMMENDATION. The Planning and Zoning Division recommends approval of this site plan request, subject to the comments included in Exhibit "C" - Conditions of Approval The Technical Review Committee (TRC) recommends that the deficiencies identified in this exhibit be corrected on the set of plans submitted for building permit. xc: Central File J;ISHROATAIPlanningISHAREOIWPIPROJECTSIQuantumIGevasINWSPIsite plan staff report Gevas.doc "3 EXHIBIT A GEVAS NORTH AMERICAN HEADQUARTERS " -------- _/~ /' .-/' //- GATeWAY BOU.E\! A~ FAl<l< QIDGE QOAD II ~ . Oto I ~~ ~O I ~~/ I / " ...../ I / ,N _ \ ~ \ ; / QUANTUM PARK PIO LOCATION MAF NTS '\- \ \ I x "\l \ ~ ~ <ll ~ \D ~ 'i ~ 9 - . ~ \\\ z \ 0 '" ~ ;z c:; s: ~ '" HI~f60GE ~~t'J ., I! -\ ~ i , . - \.. * , i- s . . ~i ~ I il U i! H p~ lJl -< ;;: t! 1 A ~ ~~ -II co ~ ~ 0 ! i' . ~ ! !~ . M C> M Z 0 o ~:~~~st M ~ m~ ' ' g . ~ gt~H ~ ~~ ~~~. ~ .s~ !l i i;' 1 iU ;a .-~ ~ :~l i gi " ~ ~B'T B ~pl I~ ~\ il ; if I H Jj \11- . 1 . .' . i1 I .l . i ~ ~ i , ! ~1 ~ "" R F~mi~ ;~ l~\~ ~ ;:1 \~ i i "" .~ r -ii (1, ih in ill 2,:;> u'! hI l;t . ~t \:~ ,-t. ~., ~; ..t IS '"'..ill ~i~ ii iit !~ .I 1 I, ~h Ii I;' ~l l~i · 'l. \~i .. it i n i ~~ U' '. is ll!l: .H~r ,rrr~ ~ r ~'~ WIth , ! r.t> I ,1\11 \ ~1 . t! i~t t ~i -i~ _f ~ · l \:< , '\~ :i!: 1t 1:;1 Jtl H "' in .t Hi ~t ~l It ,I I I \ ; \ I ~o,,"""~cc;:;~ \~ \ \_ \ ~ ,I \ \ \ \ \ '~. ~. ~~~~';:~::It:R\CAN HEAOQUARTER& _ 1" I '\ ~"" MAC>' 0\.0lOI"'" ~ i i :,~ ,. II \'" \. \' ~:j l...AN::>SCAPE Pl...A" 5 l!' d I:%' ,I I f<. ~ \ \ I: P ~1I""'-. .....~~.s._. .liI' i .J! 'o,Df'lG.... ",",""wc:'''' lnl ) :;;;::~;:~ Uii ti- ~.............. \tIR.)---- ~ e.r<-~....._L.L- .........,...,--~- --,~~_.- 1111"11 -'111111 'i I~II=I p .. i~'- ' m J I I. w.. I ~ I 'IJ I I;;'" " ~ II II! I I! I II IHI ~ .. ;8 II 'I i :~ II~. u !I~ I I ~ ~~ I~ ~ ;~ If' I ~ e i~ , . !I ~~~'___"'-__"-""""""""~oI".~~'. ~\-~-a...:~ HIBIT B i I il .!,.... ~ r I U m ~ j I 2 II ... ~ ~u ~~~~~~~rl t ~ =~-~--I ~ It>>lf._..--=I EXHIBIT "e" CONDITIONS OF APPROV AL ProJect name GEV AS NORTH AMERICAN HEADQUARTERS File number NWSP 99-017 Reference' 2nd Review New Site Plan File # NWSP 99-00 PlannIng and Zonml! Department . I DEPARTMENTS I INCLUDE I REJECT I PUBLIC WORKS Comments. 1 Construction dumpsters and service to be provided by City UTILITIES Comments. None FIRE Comments. 2 A fire flow test IS reqUIred. Roads and hydrants will be m place pnor to any constructIon above grade. POLICE Comments. None ENGINEERING DIVISION Comments. 3 Use of Quantum Park master drainage facilItIes reqUIres approval by the QCDD through QCDD permit process. 3 Show the elevations of the loadmg dock trench drain. BUILDING DIVISION 4 Correct the mconslstency WIth respect to the finIsh floor elevatIon. The site plan and floor plan drawing indIcate the finish floor as 24.50' and the CivIl plans indIcate the elevatIOn as 17.50' Withm the site data, IdentIfy the proposed finish floor elevatIon of the building (lowest floor elevatIOn) Venfy that the proposed elevatIon complIes with regulatIOns of the code by addmg speCificatIOns and notes to the site data that address the followmg issues a) From the FEMA map, identify the tItle ofthe flood zone that the buildmg IS located withm. Where applIcable, specify the base flood elevatIOn. If there is no base flood elevatIon, indicate that on the plans. As the design professlOnal-of-record for the project, state wlthm the site data that the proposed floor elevation is above the highest 100-year base flood elevatIOn applicable to the buildmg Site, as determined by the South Flonda Water Management DIstnct's surface water management '\ Page 2 GEV AS NORTH AMERICAN HEADQUARTERS File No NWSP 99-017 ~~~LA~RTMENTS INCLUDE REJECT constructIon development regulatIOns. IdentIfy the floor elevatIOn that the deSign professional has establIshed for the bUlldmg wIthin the footpnnt of the building that IS shown on the site plan, floor plan and cIvil plan. S Considering that detail drawings of the site signage were not provided and the location of the site signage was not shown on the Site plan, place the followmg note on the site plan "Site signage is not approved for thiS proJect. Separate site plan reView and approval is reqUIred for SIte slgnage " 6 Change the occupancy claSSificatIOn terminology that IS lIsted wlthm the proiect data to be consistent WIth the classificatIons lIsted m the 1997 editIon of the Standard Buildlllg Code. The plans are inconSistent with respect to identifymg the use of the faCIlIty Correct the plans accordlllgly The proJect data indicates the use as warehouse and the floor plan mdicates the use as manufacturmg/assembly Please note that With the office area of the buildmg exceeding 30% of the total floor area of the facilIty, the applicant will be reqUIred to pay Palm Beach County Impact fees based on an office use for the entire square footage of the bUlldmg. 7 Compliance WIth the BUlldmg Codes will be evaluated at tIme of permit review The permit fee, water and sewer faCIlIty fees, Fire Department fees, County fees and State fees will be determllled at time of permit review 8 To efficiently move from site plan approval to permit reView, it IS recommended that the permIt applIcant and contractor contact a Plans Analyst in the Buildmg Division of the Development Department to obtam a permit submIttal checklIst. PARKS AND RECREATION Comments. None FORESTER/ENVIRONMENT ALIST Comments. 9 The eXlstmg tree survey of the SIte shows 17 native trees, which must be replaced, or mallltained, on the landscape plan in accordance with the Tree PreservatIon Ordinance. 10 A flora and Fauna statement of the site in reference to any protected species. 11 Secure any State permits in reference to the results of #2 (If necessary) 12. A clearing and grubbmg permit for the Site can be requested after the above three Items have been completed for the Site. ~ Page 3 GEV AS NORTH AMERICAN HEADQUARTERS FIle No NWSP 99-017 DEPARTMENTS INCLUDE REJECT PLANNING AND ZONING Comments. 13 All plans shall be sIgned and sealed at time of permIt submIttal. 14 On the site plan prOVide the followmg mformation. ChA, Sec 7, Par.B - Locate wheel stops m accordance WIth CIty drawmg # B-90012. 15 In the site plan tabular data provide the followmg information. ChA, Sec.7, Par.E - Change "warehouse" to "warehouse/assembly" in parking note and parkmg calculatIOns should also be based on # of employees. Ch.2, Sec 7, Par.H.2 & Ch.2, Sec 11, Par.H.16 16 On the architectural plans provide the followmg informatIOn. ChA, Sec. 7, Para D - For all buildmg elevations and dumpster detail all architectural elements, constructIOn matenals and proposed colors m tabular form. 17 On the landscape plans proVide the followmg informatIon. Ch.7.5, Art.II, Sec.5 - Label and dimenSIOn Width of all required landscape buffers. - PrOVide notatIOn on page LND-l on the source of the irrigatIOn system ChA, Sec.7, Para C 18 PrOVide confirmatIon of review and approval of deSIgn by Quantum ReView Board. ADDITIONAL PLANNING AND DEVELOPMENT BOARD COMMENTS 19 To be determmed. ADDITIONAL CITY COMMISSION COMMENTS 20 To be determmed. J:ISHROATAIPLANNINGISHAREOIWPIPROJECTSIGEVAS NORTH AMERICAN HOQTRSINWSPICOND OF APPR P&O 8-24-99.00C C\