Loading...
REVIEW COMMENTS DEVELOPMENT DEPARTMENT MEMORANDUM NO PZ 00-253 SITE PLAN REVIEW STAFF REPORT PLANNING AND DEVELOPMENT BOARD AND CITY COMMISSION August25,2000 DESCRIPTION OF PROJECT Project Name/No Quantum Park (Lots 21-21 B) / NWSP 00-011 Property Owner' Quantum Limited Partners Ltd C/o Cohen Norris Scherer, Weinberger & Harris Applicant/Agent: Winston Lee, ASLA, AICP - Winston Lee & Associates, Inc Location Lots 21, and 21 B Quantum Industrial Park, North side of Gateway Blvd, east of LWDD E-4 Canal Land Use/Zoning Industrial/Planned Industrial Development (PI D) Type of Use Office Project Size Site Area Building Area 2.13 acres (92,783 square feet) Proposed BuildinQ 17,579 square feet Alternate A BuildinQ 15,292 square feet Adjacent Uses (see Exhibit "A" - Location Map) Quantum Park PID Water Management Tract "H", Gateway Boulevard, and further south Quantum Park PID Lot 39, Vacant; Quantum Park PID Lot 20, Allstate Insurance, L.W D D E-4 Canal, and further west Quantum Park PID Lot 1, Hampton Inn North - South East West Site Characteristics The subject vacant parcels within the Quantum Park PID contain various trees and undergrowth characteristic of disturbed scrub habitat. The survey identified various existing species including one cocoplum and scattered seagrape There are three (3) live oaks and five (5) royal palms planted at the southern end of the property with scattered exotics such as earleaf acacia, Brazilian pepper and Australian pines Passion flower, love vine and various weedy herbaceous plants and grasses occur on most of the site All earleaf acacia, Australian pine and Brazilian pepper that occur on site must be removed during the development process Existing trees of acceptable species located along rights-of-ways will be relocated when possible or replaced Proposal The developer proposes the construction of one office building totaling 17,579 square feet with 66 parking spaces on approximately 2 13 acres The project is to be constructed in one phase As part of this plan review, an alternate development option has been proposed (Building Alternate 'A') which provides for 66 parking spaces and two smaller office buildings in the same location totaling 15,292 square feet. Building alternate 'A' will contain the same roof area, but provide a covered breezeway as an entry feature between the buildings (see Exhibit lOB" - Proposed Site Plan) Concurrency' a. Traffic- A traffic statement for this project was submitted and approved by the Palm Beach County Traffic Division Page 2 Quantum (Lots 21-218)- Site Plan Review Staff Report Memorandum No PZ 00-253 b Drainage - Conceptual drainage information was provided for the City's review The Engineering Division is recommending that the review of specific drainage solutions be deferred until time of permit review Driveways There is one 24 foot wide access drive from Gateway Boulevard proposed for this project. The PID zoning district limits a project to a maximum of two driveways per each developable parcel The drive proposed will not be placed adjacent to a Gateway Boulevard median opening All traffic will have right-in / right-out circulation Parking Facility' The parking spaces required for the proposed building, 59 spaces, and building Alternate 'A' 51 spaces, have been tabulated based on the ratio of 1 per 300 square feet of office space These standard ratios have been used to calculate the parking obligations, rather than employee data as recommended by PID zoning regulations, due to the current lack of employee information Each building option proposes to include a total of 66 spaces, including two (2) handicapped accessible spaces All spaces, except handicapped spaces, will be dimensioned nine feet by sixteen and one-half feet (9 feet x 16 feet) with a two (2) foot overhang The parking area design will meet the City's Land Development Regulations, Chapter 2 - Zoning for office uses, and the ADA requirements Landscaping The landscaping of the site will fully meet code requirements when staff comments are incorporated Furthermore, landscaping enhancements are proposed including foundation hedges and plantings, and dense tree spacing intended to buffer roadway views A PID perimeter buffer is not required for these lots Building and Site Building and site regulations will be fully met when staff comments are incorporated into the permit drawings Community Design Both of the construction alternatives propose "H" shaped buildings to be constructed from concrete (tilt-up) walls arranged in a multi-faceted building face configuration All facades of each building consist of multiple windows, varied stucco surface textures with horizontal scoring All walls are proposed to be painted "Light Beige", while the window, door and railing trim will be painted "Bronze Signage The project is proposed to include one monument sign, designed consistent with the Quantum Park PID sign program, placed at the project entrance RECOMMENDATION. Staff recommends that this site plan request be approved, subject to the comments included in Exhibit "C" - Conditions of Approval The Technical Review Committee (TRC) recommends that the deficiencies identified in this exhibit be corrected on the set of plans submitted for building permit. xc: Central File S.\PlanningISHAREDIWPIPROJECTSIQUANTUM PARK LOTS 21-21BISTAFF REPORT Lots 21-21B.doc LOCATION MAP EXHIBIT "A" Quantum lots 21, 21 B Miner Road -l af\ cfI I t) ..... I\l ..... oil t> ..... of; ~ C~r- ~!- (8 Ut L- - 8 r- Site , \ , , )) ,I , ~ - ---~ ( ~,-"c~ntc~ 6"dC'" m- H;gr, ......c.nQc ----: -,--+- ---~ 5FUJMD C-l~ CaMal P....i::::l ::::;'IS't. ib"",tlon CS""Iter (NOT TO SCALE) " .:: C t; if:. .~ ~:l.ig ~~~ ~ . ~ ~ Q ~CQ. S I: "'~ ~ i~2 ;:0 ;j , " 3.,i:::;: ~a; a~~ ~~!: ....~~Q j ~< i;~~ , t ~!5~ I ~ .b~.'. .'l ,',,~i i - ~~~~; ~!;~ . I 20:)::::>'''''; ut?ld ~+!S .......::)~Q.g ...;::; .....~:::::.~ '::>jJt?d Ie :0"'1 wn1LJ.t?n6 i~H ~ I~ l : ---------------- --- ---- -.. ---- -- ~:;>o~~--~~~- -_.~ ---------- -~-=- ~ ~- co !::: CO - J: >< UJ -------~-- ~~- ---~ "t :~ . ..<....~:-- ~ ~.~_ ' ~ Oc c ~__ ~ ~':l 'i' __~_ ~=-._ -=-~__ I =-~ -------'-= ~-ii----~ \ \ , \ <. ~ ~" "c ~~___\. ~~?'- < ~~ ~<!o';"1'.3-~'09 ':'''-31';'') ~-;-- _ ~;..... {4 ' ~ - I 0 ~ ~'-, :.~ ,~, .~- - ~ ~- h 11'1'" -TI"~-"'~= ....~,,9'0 ~ _ I- _ 11_ -,- j -;--------" ~~ I ~!\ HJ .. ;H _ :-_ i Ii [- T~ i i ~i ._~~- -==., -- - --.~ - ~..;;:--:------ ~=- ~ ----0 -i: ~ ~~ ~ i =- =g ,.1;. -' ~ ''\) --- . ':t ' ~ z / ~ ~ I . " t oi;.. ,. " " H lei) 3~"T U' ~ is 5~ I l ! ~ J ! . ,., .' " , ~~ ';~ ~ ..") i~ ?! ! ! ~ l D ~ ! s I ~ :?I <5 , ~ l! ~ i~ ~ I G- 16.... H I I:i H j II J I;! ~ ~ I ~ I ~, "I ~~ I I ~~. ~ 'i ., 5l: I [jj~~~~~~ ~ : ~Q ~ ~ ~ ~ l~i~%~, :(/) .p ~Jt 7, v z " Q Q C 2 ~ ! ! ~~ 10: l ~ ~ " . C " ~ ~ ~ Q I~ o " . ~~! ~! !' ~ i ;;: -~ , ' ~ i Bll' ;; 8:' 8~1 ~I I " .: ~I;. . ~ '" . , . , ~ ~ ,~ r, ~I i i I .' ~l~ i:i~ ~ ^ " , ;~ ~~ H ~... r: r .. i~ ~I, "1(0 .i~ 8 s . ~ ~!: - HP~ ~:I ~ c;; . !ol' I '. .'~ ~'I ~..~ c, I i~ ~ > ~;; : 'j , !:~:;I' , - Ul i -: -! I f j 1 ~ ~I! -.i i ~ ! i ~ ~ t ~ r 'I 'l1il ;;~! ~~ i f ~ Wll P d ~ ~ t! 5I~ t :"dI~IL III~~I- ~ptii: ".;.~.~~~t u:c..~!; 'Q '''if''i'jl ~y.~ i ~;3 <1~~;~jIJ~~ ~t~ ~ i i ! ! .i . ,. ~l , H j ~i , I .. , ,. ~~ . r l ! ; ! " ~', -' <l z- ~~ " ... UJ2 OQ 0" ~~ -' J "~rl~! !i il~i i1Ei~1 l!}l~i i~ ~~~l "r'" " ,.l lilt .. t.t!'lCj ;! ~1~t !~;Ir: : ~H'li!: I ii i~!~! j' 'J'"' . ~!i~iH ~ z ffiE ~. :3~_ ~w~ ::l~~ 2~-E // q ~ I c Si!!?1C9C U!?!d C91!S 0 ~ VC;;)~'::Jd I -' c f?O'''~':::i -.J?;?e;g ~~g lc 'tol ~~~ ..1 ~ ~. '>j..Jf? d wn1uf?nt) ~ I ~ ~ " 9 III w \,) )- i! ~: ~t ~ ~~~ ~'~ CL.~ ll' lL if 1I! -r 4.. I'" to. .~1 _ J' " 9 III w )- ~ ~t5 Qd'lt; Q..w ~ ~loz Or~ __lL. o ll' lL 'i Il~ it .. i f! t-I ;<;1 Oil !!:I 0' o! IL: d ZI 01 ='1 631 , l:~~~ ~-!~ ,I .,--, ~~I H . ,~ H< . ~ t r ~..: <l ill t- <I zl~ ffil' h. ......JI~ <II_ :~) .~ i i , I I ~ I.!':~ 1 \l 16 & I ~ lL ~ I R!1 : 'lt~~ tl e. ~ :5J & ~! :5 E ~ : "33 5 j) ~ ~ o.G d L~ u.2 5 1~ 2 ---- '" _ u .n~:-"-~ c _ 1 .S!' n. ~ ,: ~ ~ '1: ';Ii ,J) < ~ ~ ~~ ~f ~ ',~ "" iH~ I.ni i ~2 ~~ i: ~~ 2 ~~ H ~~ ! ~ 1 \ I i I I , , I ~ S ~ 0 Z ) ~ bD r ~ l:: ..... '1:l --" - ..... g ::l l:J::l '" I r,.+ ......--- -.- . ? n -' <l t- ill Q Z I:l ill I:l Z a z <l t- db uJi~ ~ ~'~ If lL:~ ~, -:.. ~/ ~ ~-~, z \), ~~ ~~ u:l'E ~~ z _ O. Il' ' u.~ _. ~- ~ ~! t'l ~ ~ :;.~ 3, !~ t~~ j .J ~ if" ! fl '11j f.. ill {. , !j ----" ;;~~d~~~--' ,; 't ,[::J . i~. ~~-.5' ~~ ~s ~~~~ t J~ ~~ ,:i~i' ~~i ~ lf~i ~ , ~t ~;H~ I ! e~~ I I ~~ I ': . !!:'T'I ~ ii, ~~~6~a tg ~~i~~ !~:i~~ ~!. H~i~ ~k:t ,! ,~;E. llUIIlO:! :.~ "~'~!"i ~. .v ~. li~ ~.~ '.i~ ."' '0. .. 5dl ~ € ~i ~ 8~ ~i i _~.c ~'" ~ : ! -<' ~: "-. ..--. , '- ..", I ~l~ ~I; <fir; ui~ 'l g-5 D.~ <<ll ~ < I It < 0 I tm I~ ~ ~J i I 3 = . <u I ~~ i I v ~ .' P' J v ~ III ~!~ ~~~ ~:" Q)!~ .. I v i I g" @ . ! ~3 .~ . t<. ~ ill 1 v~5 Et, 0 -' :;,~ !di ~I I z,~ *!? I ~I~ lLli ! ~ ~ ~i~ I' r;,. I ~!' I '~I = ___;~~~--t--~ ~-~~ -I' i .\"1''' , ~I (; 1 ~I 2 ~ - ~~; t m~ i! ;~ ~ ~Q ~ ~ . ~--, I j i i~ ~.., ....:.. l : ;\ \ \ .,.." < \ = \ \il'.it~ id\ "I i ~-'j V;I 'I ~s j I: u . . ~ I j" f' "';~.____\_'~f'~ I. _~. ~ , ~-.: ~_._---~._.--.f-"'" I Oij ~ } . ~ < . u " !l ;1 ~~ g ~ ~G 1 ~~ ,~~~ '~l~-" II I~ ---'~--'" .' ~ ~'" ~r '1 . ~ o ~~ ~~ ;i ~~ ~~ ~ti ~~ 1~ , . c~ ........1 --...f_.... ~;i~ ; ~-... , .IL "I' -" <l! t;J! at 01 ~I u Q ZI ~ ~E -8 en ~ en - ::c >< w Z! -<I ___H lLl I jl "11 . :n[_~ (lllD z,~? \ll~~ cr::!~-:! ~:q lLi~' <l'! '.11 ~ \II; "11'. :IE \0 z' "1 -' lL -' d OC<J) i~ ~ "'I al ~" ~lL @) z "1 -' lL -' d 1l'<J) l!'" :~ .,ll Illl' 1-"1 ~lL \~ ~I oc ~I w-' ~<1 ~t- oc"' ~~ ~~ Illl' "-.. ~ Q.., ,~ '- ill -' <l t- ill Q -' -' <I ~I 191' Z~ ;;Zi~ ~I~ oJ~ I~\i \2l!-J; -"'~""'" -- .- , ~ ,~~~-"~I ! ~ ,I '?l:"" ... 1'?'iJ )(';"'~ Cl ."" :~'iJ '" 1-9 \\'1 "t--... '7<::~.:"" I-:>,;",,,g '"C....J..C>g 9l91::'1O:> "T':' "Tc.;O'O....,. :o..o!~~::c-a ',-9 ~ , '1-9 ; ,-- ~~-I l...r) I GI',~ J.."7n=':'~"'i..:"'t Q;, ;l..:""i -';"~ C"';;..:':":> l'ii3T. ~ ~ ~.:: -=1 Ii \ \- J l !1-9 \\~ ~I , ,1-.=0 ji :1 - y .LiY - II.lG7 daGl.':) Irr.:..NY'7ib .~ Y.J .I.J:J.:.m:;uy - .....CS7':/yJ il.1..lS."-:i;{ ,I ..~~:l....: ! ~~~.... cCC.OJ I i ~ ! -.. -...0 " ~ I ~ . I .'- ( ;~;: ~;: : l ;'-, I , r,~C I. LO! .:" lJj (\\ II ,I if' -. IJII! "-,--) II ill _, i~ i i -:j ;il I . 'Y-U 1_'~_:~_11 t ;----:,T\!~,; -=--C"--/? , !~m [H! "t"l. lr.'~ Ill: '" >,.. 01" h ~! 1>.' '" ~! ~; e::: ~ ......' 0'. Ct)14' rr.o. \J:JI fl ~ll' -. --:rl -,- I .. --:'! - ! .I , .';:' 1_':1 I' lfl+rr.!!' tttt'i f~:~-~l r-. _ ~ rl[ l,~jl 1 ,--.,,- . d, -,-~ f-.--~/ -.!J..__-lLJ_-..1il L_~- f~ rOJ I f~c~~~ ~,! ' ~:. ,I:: ~:~:_~;~: . .,' . . ~ L~ ~_ ~J -. . ::i -- , I ~i ~":'::':'II! . rh~l'li ~: . ,'-'I -- I ">' '" I r- 1'-'- I I C1~f;'J\ 2i" ..,J----'-==.I:"-./\' Il~ .[~~..-:.~.\ l"!:~j) i;, ~I ~! \ \...LY ~.~ ; ".~ \ .~, . .)! I" ~i" Jr -lIr -~r '" ~ ~ '" :x; '-' v, ~.:J~. i Q <!'.-L .V I , 1 , I ,I r r:!; r .w I , ! ; I <----.;-;-1 ~ ----, \ ':, ',LI i! ii I -,--:!\ ~ ~ i l ; I ~. I., ; I Ii-'---~i \ I~- (~\! (,' jl \ -, : i'~ ! -~-.t\l .~ . : : _ lei ? ~ r-.=J. I 'L~ ~\ [I ! I =-~:;I ~ " ! ;; 1 .... ~ \ ! I'" LJ: i h--- i i ~~:~ 'ii ~ \. \ i ~ I <;....~.Ii, I '~ \ 'l.... l ' ,,! \u ~I;j LJ !,:J_1 j-I i; ;-J~! LL.I rr r:J. t.f1!1 II ''-'j ;-n Ii I FooLlj "'[1(" +"~I:~~.:j : _LI'~! , i ;-~_i ;'nrrl 11:i - --.I co ..... CO - I X UJ ~: s: ,; ~i hI '" 0' ~- (,-A !~ U f' , fI t--~~l I-l~ "II ! ~I~P .1 II . ~ _.:: ! 'I ' i I ( I -:, h II~ Jt.'~J~11 " ,\! _:'''- II " \ j..},;..:1 , fl- :,J :I .' ! , j '. , 1-- .II -j :1 ) J :-~-~~!l i! ~: ".-::-1 ' ~J; i I. . r_j ~), I, , ~~ -.. r-r-i L' r'u~! '} ") '- ..J r ... ...I'~ l'7-:~~ --. ~}~-.:=J::;-;\l i;' :<:.. 0: hi ;;:'i "'I "-" ~l ....' E:~ Ie l"J ". " ,./ ~: ;r- N'V'1d 9NlN'V',d ~ ~ \, \\ ;1 , ' \l ~L c C ~ ~I E ~~~ S \ H \ ~~ . ~ eoC'./- v-.:;eo;;~ ~c1Jfc'C: It A~O\ ";:o\JE? d U,;\l1J.enO ----- -------~_._----- ---- ~---~ .<.-..--. ...-...-. ... / . ._. . .c.c.::'. / ;.:': _.;;::::::::~ccc~c==,:_-- --. ... ..... =_~._ _ _.=_._~~_.._~/.__ ~.v/=_." ~\ ~~ ~ , . .i ~ { ~. 5, ~ , ~ ~~ ~ ~ " J " t ~~ G \)6 :; ..~ ;i W~ ~ ~ \:. " .. " ~ Q " \! '" 0 '& u\ U1 .. __ _ _ ~ \i ->-~ - - - .. f. \L 11- {( . t t( !O~~ ()i .~.~ t\~'" ,,~ \$';& .~~~r." i~ - - - - t --" - - ,... - - ... IlC ll- ~ 4\ i'i \' \ t~ /1 ~ ~ \' . _~1~~-, .~- \ ~~ . ,,1 ( \ <;\ "\ ~\ \ \ .-,,' j.........,......- - - _.- - - - - - - ,- - - - -" / :1" . <L .~ ~. \; ~iB / " -. ~ " ,9' '" \~ ~ ) ~ ~ .-,,' " .~.,.,......- .<'.?' /.4:"" .. ~?~.. ./ i- ~~ t\ t~ // ~ . ~\ :.e ~ ~ I -I I ~ . i' ,! !~ Ii \.\ 'l'lll cd. UI >I. ., .J ~; /' 0r -.'" !"lll \l. . ~ ~ .../ ./ ~ C cO - ~ \.U /-- ----------- /.... EXHIBIT "C" CondItIons of Awroval Project name' Quantum Park Lots 21 & 21B FIle number NWSP 00-011 Reference' 2nd reVIew plans Identlfied as New SIte Plan. File # NWSP-OO-Oll wIth a August 22,2000 Planmng dZ . D d b an omnl! eoartment ate stamo mar ng. DEPARTMENTS INCLUDE REJeCT PUBLIC WORKS Comments. NONE UTILITIES Comments. GENERAL COMMENTS 1 Palm Beach County Health Department pernuts may be reqmred for the water and sewer systems serving this project (CODE Sec 26-12). Duect samtary servIce connectlOn to the manhole IS not permItted. EIther add an extenslOn to the mam hne to accommodate the proJect's proposed wastewater servIce, or msert a lateral 'wye mto the existmg lme a mmlmum of 5 feet m front of the manhole (whIch may put your lateral onto the adjacent property). 2. CODE Sec 26-34(E) reqmres that a capacIty reservatlOn fee be paId for thIS project eIther upon the request for the Department's SIgnature on the Health Department apphcatlOn forms or Wlthm 30 days of SIte plan approval, whIchever occurs first. ThIS fee will be determmed based upon final meter SIze, or expected demand. SPECIFIC CONDITIONS 3 Water and sewer hnes to be owned and operated by the CIty shall be mcluded wlthm utlhty easements. The easement shall be dedIcated VIa separate mstrument to the CIty as stated in CODE Sec 26-33(a). FIRE Comments. 4 A fire hydrant flow test IS reqmred onor to SIte plan approval. (LDR 6-16) 5 Access road and hydrant will be m place pnor to above grade constructlOn. POLICE Comments. NONE ENGINEERING DIVISION Comments NONE I DEPARTMENTS l INCLUDE I REJECT I BUILDING DIVISION Comments 6 At time of permIt reVIew, proVIde detaIled drawmgs and documentatIOn on the plans that will venfy that the accessible route that IS shown on the plans from the accessible parking spaces to the accessible buildmg entrance IS m complIance wIth the regulatIons of the Flonda AccessibilIty Code for Buildmg ConstructIOn. The documentation shall mclude, but not be lImIted to, IdentIfymg the type of matenal proposed for the route, type of surface fimsh, wIdth, cross slope, slope and length of the entIre accessible route mcludmg, where applIcable, landmgs, ramps and handrails. 7 At tIme ofperrmt reVIew, specIfy (in tabular form) on the sIte plan and/or floor plan the proposed use of the facilIty, type of construction and occupancy classIficatIOn of the buildmg. The buIldmg area, occupancy classIficatIOn and type of constructIOn shall comply wIth the speCIficatIOns IdentIfied m the 1997 edItIon of the Standard Building Code, mcludmg the CIty of Boynton Beach amendments to the Standard Buildmg Code. W orkmg drawmgs of the buildmg shall comply wIth the codes speCIfied m Chapter 20 of the Land Development Regulations. 8 The permIt fee, water ad sewer facilIty fees, FIre and Life Safety fees, County fees and State fees will be determIned and assessed at tIme of permIt reVIew 9 PermIts are reqUIred to construct the Improvements that are shown on the approved sIte plan/condItIOnal use documents. Permit applIcation forms are avaIlable m the Buildmg DIVISIOn of the Development Department. A permIt submittal checklIst is available in the Building DIVISIOn. The lIst identIfies the baSIC documents that the Plans Analyst checks for when an applIcant submits for permIt reVIew PARKS AND RECREATION Comments NONE FORESTER/ENVIRONMENTALIST Comments. NONE PLANNING AND ZONING Comments 10 ProVIde wntten venficatIOn that would allow the protected viewmg area to extend mto tract "H" (dramage tract). The wntten venficatIOn shall be from the entIty that controls the dramage easement as described on the plat drawmg that IS referenced on the survev that was submItted. ADDITIONAL PLANNING AND DEVELOPMENT BOARD CONDITIONS I DEPARTMENTS l INCLUDE I REJECT I 11 To be determined. ADDITIONAL CITY COMMISSION CONDITIONS 12. To be determmed. MWR/blw J:ISHRDATAIPLANNINGlSHAREDlWPIPROJECTSIQUANTUM PARK LOT 21 & 21BI1ST REVIEW COMMENTS,DOC DEVELOP"~NT ORDER OF THE CITY COMMf 'ION OF THE vI TV OF BOYNTON BEACH, FLORluA PROJECT NAME Quantum Park lots 21-21B APPLICANT'S AGENT Winston Lee, ASLA, AICP - Winston Lee & Associates, Inc. APPLICANT'S ADDRESS 712 U S Highway One, N Palm Beach, Florida 33408 DATE OF HEARING RATIFICATION BEFORE CITY COMMISSION September 19,2000 TYPE OF RELIEF SOUGHT New Site Plan LOCATION OF PROPERTY North side of Gateway Blvd East of and adjacent to the L.W D D E-4 Canal DRAWING(S) SEE EXHIBIT "B" ATTACHED HERETO THIS MATTER came before the City Commission of the City of Boynton Beach, Florida appearing on the Consent Agenda on the date above The City Commission hereby adopts the findings and recommendation of the Planning and Development Board, which Board found as follows OR THIS MATTER came on to be heard before the City Commission of the City of Boynton Beach, Florida on the date of hearing stated above The City Commission having considered the relief sought by the applicant and heard testimony from the applicant, members of city administrative staff and the public finds as follows 1 Application for the relief sought was made by the Applicant in a manner consistent with the requirements of the City's Land Development Regulations 2. The Applicant HAS HAS NOT established by substantial competent evidence a basis for the relief requested 3 The conditions for development requested by the Applicant, administrative staff, or suggested by the public and supported by substantial competent evidence are as set forth on Exhibit "C" with notation "Included" 4 The Applicant's application for relief is hereby _ GRANTED subject to the conditions referenced in paragraph 3 hereof DENIED 5 This Order shall take effect immediately upon issuance by the City Clerk. 6 All further development on the property shall be made in accordance with the terms and conditions of this order 7 Other DATED City Clerk J:ISHRDATAIPlanningISHAREDlWPIPROJECTSIQuantum Park Lot 21 & 21 BIDevelop.Order Form-,Revised.doc ~~L PrOject name Quantum Park Lots 21 & 21B File number NW&P,~O-OII Reference ~revrw plans ~J/I: . ~. ~ .cl'_M~ Identified as New Site Plan. File # NWSP-OO-Oll with a tlu(f'k J~J11~1 ~. 2000 Planmng and Zoning Department date stamp marking. DEPARTMENTS INCLUDE REJECT PUBLIC WORKS Comments NONE UTILITIES Comments. GENERAL COMMENTS 1 Palm Beach County Health Department permIts may be reqUIred for the water and sewer systems servIng this project (CODE Sec. 26-12). DIrect samtary servIce connection to the manhole IS not permItted. EIther add an extenSIOn to the maIn line to accommodate the project's proposed wastewater service, or Insert a lateral "wye" into the existIng hne a mInimum of 5 feet In front of the manhole (WhICh may put your lateral onto the adjacent property) 2. ODE Sec. 26-34(E) reqUIres that a capaCIty reservatIOn fee be paId for thIS project eIther upon the request for the Department's signature on the Health Department applIcation forms or WIthin 30 days of site plan approval, whIchever occurs first. This fee will be determIned based upon final meter size, or expected demand. SPECIFIC CONDITIONS ater and sewer lines to be owned and operated by the CIty shall be included WIthin utilIty easements. The easement shall be dedIcated VIa separate Instrument to the CIty as stated In CODE Sec. 26-33(a). 5 FIRE e Clat,..).r, ~ rbt' ~~ 6 A fire hydrant flow test IS reqUIred (LDR 6-16) DEPARTMENTS Access road and hydrant will be m place pnor to above grade construction. POLICE Comments. IJDut ENGINEERING DIVISION Comments /1; D}Jt, 9 0 he cIvIl plan, add the general note that the stnping, markings and sign e shall conform to city standard drawmg B-9800 1 Correct the typical HlC p rkmg stall detail on th~ sIte plan detaIls. lOOn the s e and civIl plans/change the egress arrow markmg to a nght turn only arro . Add a "nghyturn only" post sign to the stop sIgn and a one-way arrow sign' the media. Also, add double yellow lane separatIOn stripes at thee entranc (CH. 4, ectIon 7B). II It is recommen ed t ~t in lieu of a stop sign/bar at the crosswalk, a "yield to pedestrian" sign used for more efficIent traffic CIrculatIOn. 12 On the CIVIl pIa s, d a general note that the dramage system shall conform to CIty standar draw g B-91 007 13 It IS recom nded that rb cuts be placed m the contmuous curb for the 5 parking sp ces opposite b ildmg entrance to dIrect storm water mto the landscap area. 14 the SIte plan. "All plans submItted for speci c permits shall meet the . 's code reqUIrements at time of appl. atlon. These permIts mcIud but are not limIted to the following: site hg ing, pavmg, dramage, curbmg, I dscaping and lITIgation. PermIts r UIred from other permItting agencI such as FDOT, PBC, SEWMD, ERM, L WDD, DEP and others, shall ~ mcluded WIth the permIt request" \ \ On the SIte and CIvIl plans, show the sidew k through the dnveway with a mimmum thickness of 6 mches (CH. 23 Art. I P) BUILDING DIVISION vi Comments. 16 Add to the bUIldmg that is depIcted on the drawing titled SIte plan (incIudmg bUIlding labeled Alternate A) a labeled symbol that Identifies the location of the handIcap accessible entrance doors to the each tenant space of each INCLUDE REJECT DEPARTMENTS buildmg. INCLUDE REJECT 17 On both floor plan drawings, add a labeled symbol that Identifies the location of the handicap accessible entrance door to each tenant space The location of the door(s) shall match the location of the accessible entrance doors that are depicted on the site plan drawmg, mcluding Alternate A footpnnt drawmg. 18 Add a labeled symbol to the site plan that represents and delmeates the path of travel for the accessible route that IS reqUired between the accessible parkmg spaces and the accessible entrance doors to each tenant space, Add the accessible route to the footpnnt of Alternate A building. The symbol shall start at the accessible park 109 space(s) and term mate at the accessible entrance door to each tenant space The symbol shall represent the locatIOn of the path of travel, not the locatIOn of the detectable warning or other pavement markmgs that are required to be installed along the path. Identify on the plan the Width of the accessible route that IS located adjacent to the buildmg (note. the minImum Width required by the code IS forty-four (44) mches). Add text to the drawmg that would mdlcate the symbol represents the accessible route and the route IS deSigned 10 complIance with Section 4.3 (Accessible Route) and 46 (Parkmg and Passenger Loadmg Zones) of the Flonda AccessibIlity Code for BUlldmg ConstructIOn. Please note that at time of permit review the applIcant shall prOVide detailed documentatIOn on the plans that will venfy that the accessibilIty route IS in complIance With the regulatIOns speCified in the Flonda AccessibilIty Code for Building Construction. This documentatIOn shall mclude, but not be limited to, prOViding finIsh grade elevations along the path of travel. 19 Venfy that the 14.5' proposed finIsh floor elevation IS in compliance with regulations of the code by add 109 speCificatIOns to the site data that address the following Issues [SectIOn 3107 1.2, Chapter 31 of the Boynton Beach amendments to the 1997 editIOn of the Standard Buildmg Code] a. The deSign professlOnal-of-record for the project shall add the followmg text to the site data. "The proposed floor elevatIOn NGVD IS above the highest 100-year base flood elevation applIcable to the building site, as determmed by the South Florida Water Management Distnct's surface water management construction development regulatIOns." b Identify the floor elevation that the deSign professional has established for the buildmg withm the footprmt of the buildmg that IS shown on the site plan, floor plan and Civil plan 20 ProVide wntten verification that would allow the protected Viewing area to extend into Tract "H" (drainage track) The wntten venficatlOn shall be from the entity that controls the drainage easement as describe on the plat drawing that is reference on the survey that was submitted. 21 Indicate, Within the footprmt of the buildmg that is shown on the site plan, the number of stories that are in the buildmg includmg mezzanines, where applicable. DimenSIOn the overall height of the buildmg on the elevation view drawing of the bUlldmg. DEPARTMENTS 22 On all floor plan drawmgs, mdlcate wlthm the footprmt of the building the number of stones that are In the buildmg Including, where apphcable, mezzamnes. 23 The bUIldIng plans are not bemg revised for comphance with the apphcable building codes. Therefore, add the words "Conceptual Floor Plan" below the drawmgs titled Floor Plan found on both sheets Identified as A-4 Renumber one of the sheets. 24 Indicate on the floor plan draWIng (17,579-sq ft. plan), within the floor area, the proposed use of the structure. PARKS AND RECREA nON Comments. NONE FORESTERlENVIRONMENTALIST Comments 25 The apphcant had addressed preservatIOn and relocation of all the deSIrable trees on the site. PLANNING AND ZONING Comments. 26 ReVise the apphcatIOn and plans to clanfy the use ofb6I1ding alternate 'A' rrently the plans show the use of both buildings.;the site plan shows one bui ng type and the Civil drawmgs show the u;fof bUIldIng alternate' A' Submi written justification and traffic repo oescribIng the proposed use of alternat uildIng 'A' In the justlficatio describe when and why the alternate buil g would apply As discus d In the pre-apphcation meeting, a phased plan wa to be submitted whiciutilized the 15,292 sf. buildIng. Submitted plans in ate no phases a the use ofthe 17, 579 sf. building. If the plans are review and appr ed utlhzIng the larger buildIng, any reVisions regardIng the us f th alternate buildIng will require the modificatIOn of the site and dscape plans of record ( ChA, Sec 7 Par.B I). ReVise the survey to in ude the 40' dra age easement located along the north property hne ( hA, Sec 7, Par.A.3). Revise the site an to indIcate the correct buIlding eights as they relate to the architectu I plans. Correct architectural plans to ow overall buIlding heIght dIm SIOns. Clanfy the site plan data to indicate t correct heIght InformatI n for both buildmg optIOns (ChA, Sec 7, Par.B 1). \J 29 On t landscape plan, reVIse the plant hst to Include a plant material related to t e ,CL plant tag found at the southwest corner of the site (ChA, Sec.7, INCLUDE REJECT ct( DEP ARTMENTS INCLUDE REJECT WR/blw J:ISHRDATAIPLANNINGISHAREDlWPIPROJECTSIQUANTUM PARK LOT 21 & 21 811 ST REVIEW COMMENTS. DOC f{VD ~ 1 # t {[)VIC~ LPtJJJ:t1 ver c?.-fzCM. Cn.-o+ 4-vald cJ.iau k f1'b}' ~J V I ~ IY'3 J'-fO- ~ ~~*-'~ l rLh ---rracJ- l +~ L ( ldJ2..zvn2q,e trod-.. ~ /) . hL +rf:ryy, ~ {) 0 ~~AAcr\ verf( W(jj.11 shxL. ~ - - .:ktJ ~f- (mJy;0s ~ d R? tl2 J! 4/11 meJ a ~ des Ui!.tb-ed 6'v\ lfl,Q J I T _1 ~ ct~ctA-.AA R.t0' J { 0:. c~rck. tl'j (ct.e\ll(eD 01\1'\ ~ S,V(ZU-eL/iJ-d- LLvJ) $-ub~d, v DEP ARTMENT OF DEVELOPMENT BUILDING DIVISION MEMORANDUM NO 00-256 PLANNING AND ZONING DEPT TO MIchael Rumpf, DIrector of Planmng and Zonmg e./ MIchael E Haag, BUIldmg Code AdmmIstrato;--\ FROM DATE August 24, 2000 RE Quantum Park Lots 21 & 21B - New Site Plan (N 2nd review comments We have revIewed the subject plans and recommend that the request be forwarded for Board reVIew WIth the understandmg that all remammg comments WIll be shown m complIance on the workmg drawmgs that are submItted for permIt reVIew Buildin~ Division (Site Specific and Permit Comments) - Michael E. Haa~ (561) 742-6352 I At tIme of permIt reVIew, prOVIde detaIled drawmgs and documentatIOn on the plans that WIll venfy that the accessible route that IS shown on the plans from the accessible parkmg spaces to the accessible bUIldmg entrance IS m complIance wIth the regulatIons of the Flonda AccessibIlIty Code for BUIldmg ConstructIOn. The documentatIOn shall mclude, but not be lImIted to, IdentIfymg the type of matenal proposed for the route, type of surface fimsh, WIdth, cross slope, slope and length of the entIre accessible route mcludmg, where applIcable, landmgs, ramps and handraIls. 2 At tIme of permIt reVIew, speCIfy (m tabular form) on the SIte plan and/or floor plan the proposed use of the faCIlIty, type of constructIon and occupancy claSSIficatIOn of the bUIldmg. The bUIldmg area, occupancy claSSIficatIOn and type of constructIon shall comply WIth the speCIficatIOns IdentIfied m the 1997 edItIon of the Standard BUIldmg Code, mcludmg the CIty of Boynton Beach amendments to the Standard BUIldmg Code W orkmg drawmgs of the bUIldmg shall comply WIth the codes speCIfied m Chapter 20 of the Land Development RegulatIOns. 3 The permIt fee, water and sewer faCIlIty fees, FIre and LIfe Safety fees, County fees and State fees WIll be determmed and assessed at tIme of permIt reVIew 4 PermIts are reqUIred to construct the Improvements that are shown on the approved SIte plan/condItIonal use documents PermIt applIcatIOn forms are aVaIlable m the BUIldmg DIvlSlon of the Development Department. A permIt submIttal checklIst IS aVaIlable m the BUIldmg DIVISIOn. The lIst IdentIfies the baSIC documents that the Plans Analyst checks for when an applIcant submIts for permIt reVIew MEH bg \ICH\MAIN\SHRDA T A Development\Building-6870\Documents\TRC\NWSP 00-0 II 2nd review Quantum Park Lots 21 & 2 I B.doc 1 st REVIEW New SIte Plan Project name. Quantum Park Lots 21 & 21B File number. NWSP 00-011 Reference. 1 st review plans consist of 12 sheets Identified as New Site Plan. File # NWSP-OO-O 11 with a Julv 12.2000 Plannmg and Zomng Department date stamp marking DEPARTMENTS INCLUDE REJECT PUBLIC WORKS Comments. NONE dJK. ~ MA.L UTILITIES Comments. GENERAL COMMENTS I Palm Beach County Health Department permits may be reqUired for the water and sewer systems servmg this project (CODE Sec. 26-12). Direct samtary service connection to the manhole is not permitted. Either add an extensiOn to the mam hne to accommodate the proJect's proposed wastewater service, or msert a lateral "wye" mto the eXlstmg line a mmlmum of 5 feet in front of the manhole (which may put your lateral onto the adjacent property). 2 Fire flow calculations will be reqUired demonstratmg the City Code requirement of 1,500 g.p.m. as stated m LDR Chap 6, Art. IV, Sec 16, or the reqUirement imposed by insurance underwnters, whichever IS greater (see CODE Sec 26-16(a)) 3 CODE Sec 26-34(E) reqUires that a capacity reservatiOn fee be paid for this project either upon the request for the Department's signature on the Health Department apphcatiOn forms or wlthm 30 days of site plan approval, whichever occurs first. ThiS fee will be determined based upon final meter size, or expected demand. SPECIFIC CONDITIONS 4 Water and sewer lines to be owned and operated by the City shall be included Within utihty easements. The easement shall be dedicated via separate instrument to the City as stated m CODE Sec. 26-33(a). 5 This office will not reqUire surety for installatiOn of the water and sewer utilities, on conditiOns that the systems be fully completed, and given to the City Uttlities Department before the first permanent meter IS set. Note that settmg of a permanent meter IS a prerequisite to obtammg the Certificate of Occupancy FIRE 6 A fire hydrant flow test IS reqUired (LDR 6-16). 1 st REVIEW New SIte Plan 7'-- /~' ~ I . _____ ,1 PrOject name. Quantum Park Lots 21 & 21B File number' NWSP 00-011 Reference. 1 st reVIew plans conSIst of 12 sheets IdentIfied as New Site Plan. FIle # NWSP-OO-Oll wIth a Julv 12 2000 Plannm!! and Zonm!! Deoartment date stamp markin!! , \ ) .J , DEPARTMENTS INCLUDE REJECT PUBLIC WORKS Comments. NONE UTILITIES Comments. GENERAL COMMENTS ~. ~. ( I Palm Beach County Health Department permIts may be required for the 1)_ I--- - water and sewer systems servmg thIS project (CODE Sec 26-12) DIrect JC_ sanitary servIce connectIon to the manhole IS not permItted. EIther add an -" extenSIOn to the main hne to accommodate the project's proposed wastewater servIce, or msert a lateral "wye" mto the eXIstmg hne a mmImum of 5 feet 10 front of the manhole (WhICh may put your lateral onto the adjacent property). 2 Fire flow calculations wIll be required demonstratmg the CIty Code ~~ reqUIrement of 1,500 g.p.m. as stated 10 LDR Chap 6, Art. IV, Sec 16, or the reqUIrement Imposed by msurance underwnters, whIchever IS greater (see CODE Sec. 26-16(a)) ~ .... ~i CODE Sec. 26-34(E) reqUIres that a capaCIty reservatIOn fee be paid for thIS " project either upon the request for the Department's sIgnature on the Health I) Department application forms or WIthin 30 days of SIte plan approval, "-..( J ~ whIchever occurs first. ThIS fee WIll be determined based upon final meter ;-..... '--.::: size, or expected demand. SPECIFIC CONDITIONS I "- (~ \ Water and sewer hnes to be owned and operated by the City shall be ~ .... mcluded wlthm utIlity easements. The easement shall be dedicated VIa I ..... separate mstrument to the CIty as stated in CODE Sec 26-33(a) " '- \ 5 This office will not requIre surety for installatIOn of the water and sewer I r "'- utIhties, on condItIons that the systems be fully completed, and gIVen to the City UtilItIes Department before the first permanent meter is set. Note that settmg of a permanent meter IS a prereqUIsite to obtaming the CertIficate of --............ Occupancy FIRE 6 A fire hydrant flow test is reqUIred (LDR 6-16). Project name: Quantum Park Lots 21 & 21B File number" NWSP 00-011 Reference: 1st reVIew plans consist of 12 sheets Identified as New SIte Plan. File # NWSP-OO-Oll Julv 12 2000 Planninl! and Zoninl! Department date stamp markinl! 1 st REVIEW New SlteP~ wIth a . DEPARTMENTS INCLUDE REJECT PUBLIC WORKS Comments NONE UTILITIES Comments. GENERAL COMMENTS 1 Palm Beach County Health Department permIts may be reqUIred for the water and sewer systems serving thIS project (CODE Sec 26-12) DIrect sanitary service connection to the manhole IS not penmtted. EIther add an extenSIOn to the mam hne to accommodate the proJect's proposed wastewater servIce, or msert a lateral "wye" mto the eXIsting hne a mmlmum of 5 feet in front of the manhole (which may put your lateral onto the adjacent property) 2. Fire flow calculatIOns WIll be required demonstrating the CIty Code reqUIrement of 1,500 g.p.m. as stated in LDR Chap 6, Art. IV, Sec. 16, or the requirement Imposed by msurance underwnters, whIchever is greater (see CODE Sec 26-16(a)) 3 CODE Sec 26-34(E) reqUIres that a capacIty reservatIOn fee be paId for thIS project eIther upon the request for the Department's signature on the Health Department application forms or within 30 days of sIte plan approval, whIchever occurs first. This fee WIll be determmed based upon final meter size, or expected demand. SPECIFIC CONDITIONS 4 Water and sewer lines to be owned and operated by the CIty shall be mcluded withm utility easements. The easement shall be dedicated Via separate instrument to the CIty as stated m CODE Sec 26-33(a) 5 ThIS office will not reqUIre surety for mstallatIOn of the water and sewer utIlities, on conditIons that the systems be fully completed, and given to the CIty Utihties Department before the first permanent meter is set. Note that settmg of a permanent meter IS a prerequisIte to obtammg the CertIficate of Occupancy FIRE 6 A fire hydrant flow test IS reqUIred (LDR 6-16). X' DEPARTMENTS INCLUDE REJECT 7 Access road and hydrant wIll be in place prIor to above grade constructiOn. --r POLICE Comments. 8 "Right Turn Only" sign to be placed at drIveway exit onto Gateway Blvd. Traffic flow for parkmg lot not shown. ENGINEERING DIVISION Comments. 9 On the civil plan, add the general note that the stripmg, markmgs and slgnage shall conform to City standard drawing B-98001 Correct the typical HlC parkmg stall detail on the site plan details. 10 On the site and civil plans, change the egress arrow marking to a rIght turn only arrow Add a "right turn only" post sign to the stop sign and a one-way arrow sign in the median. Also, add double yellow lane separatiOn strIpes at thee entrance (CH. 4, Section 7B). 11 It is recommended that m lieu of a stop slgn/bar at the crosswalk, a "Yield to pedestrIan" sign be used for more effiCient traffic Circulation. 12 On the civil plans, add a general note that the dramage system shall conform to City standard drawing B-91 007 13 It IS recommended that curb cuts be placed m the continuous curb for the 5 parking spaces opposite bmldmg entrance to direct storm water mto the landscape area. 14 Add a followmg general note on the site plan. "All plans submitted for speCific permits shall meet the City's code requirements at tIme of apphcatIOn. These permits mclude, but are not limited to the followmg: site hghtmg, paving, dramage, curbmg, landscaping and lITIgation. Permits reqmred from other permlttmg agencies such as FDOT, PBC, SEWMD, DERM, L WDD, DEP and others, shall be included With the permit request" 15 On the site and ciVil plans, show the sidewalk through the driveway with a minimum thickness of 6 inches (CH. 23 Art. lIP). BUILDING DIVISION Comments. 16 Add to the bmldmg that IS depicted on the drawmg titled site plan (including building labeled Alternate A) a labeled symbol that IdentIfies the location of the handicap accessible entrance doors to the each tenant space of each DEPARTMENTS INCLUDE REJECT 7~oad and hydrant will be In place prIor to above grade constructIOn. ( 1\) POLICE --- ~roV4~ 8/~oo 4 .." , Comments. 8 "Right Turn Only" sign to be placed at drIveway exit onto Gateway Blvd. Traffic flow for parkIng lot not shown. ENGINEERING DIVISION Comments. 9 On the ciVil plan, add the general note that the strIping, markIngs and slgnage shall conform to city standard draWIng B-9800 1 Correct the typical HlC parkIng stall detatl on the site plan detaIls. 10 On the site and civIl plans, change the egress arrow marking to a right turn only arrow Add a "right turn only" post SIgn to the stop SIgn and a one-way arrow sign In the medIan. Also, add double yellow lane separatIOn stripes at thee entrance (CR. 4, SectIOn 7B). 11 It IS recommended that in heu of a stop sIgnlbar at the crosswalk, a "YIeld to pedestrian" sign be used for more effiCIent traffic CirculatIon. 12 On the civil plans, add a general note that the draInage system shall conform to city standard drawmg B-91 007 13 It IS recommended that curb cuts be placed in the contInUOUS curb for the 5 parkIng spaces opposite buildIng entrance to direct storm water into the landscape area. 14 Add a follOWIng general note on the SIte plan. "All plans submitted for speCific permits shall meet the City's code requirements at time of application. These permits Include, but are not hmited to the following: site hghting, pavIng, draInage, curbing, landscapIng and irrIgatIOn. Permits reqUIred from other permittIng agencies such as FDOT, PBC, SEWMD, DERM, L WDD, DEP and others, shall be included WIth the permIt request" 15 On the site and ciVIl plans, show the Sidewalk through the drIveway With a mInimum thickness of 6 Inches (CR. 23 Art. lIP). BUILDING DIVISION Comments. 16 Add to the buildIng that IS depicted on the draWIng titled site plan (includIng buildIng labeled Alternate A) a labeled symbol that identifies the location of the handicap accessible entrance doors to the each tenant space of each DEPARTMENTS INCLUDE REJECT 7 Access road and hydrant will be m place pnor to above grade constructIOn. POLICE Comments. 8 "Right Turn Only" sIgn to be placed at dnveway exit onto Gateway Blvd. .~ -- )~ / ~ uOW for parkmg loot shown. ( ENbINEERING DIVISION ~nts. ~ 9 On the cIvil plan, add the general note that the stnping, markmgs and o if{ sIgnage shall conform to CIty standard drawing B-9800 1 Correct the typical HlC parkmg stall detaIl on the sIte plan details. 1 10 On the sIte and cIvIl plans, change the egress arrow marking to a right turn only arrow Add a "nght turn only" post sign to the stop SIgn and a one-way arrow SIgn m the medIan. Also, add double yellow lane separatiOn stnpes at thee entrance (CH. 4, Section 7B). 11 It IS recommended that m heu of a stop sIgnlbar at the crosswalk, a "YIeld to pedestrIan" SIgn be used for more efficient traffic cIrculation. 12 On the civil plans, add a general note that the drainage system shall conform to CIty standard drawing B-91 007 13 It IS recommended that curb cuts be placed m the contmuous curb for the 5 parkmg spaces OpposIte bUIlding entrance to dIrect storm water mto the landscape area. 14 Add a followmg general note on the SIte plan. "All plans submItted for specIfic permIts shall meet the CIty'S code reqUIrements at time of apphcation. These permits mclude, but are not hmited to the followmg: SIte lightmg, pavmg, dramage, curbmg, landscapmg and lITIgation. PermIts reqUIred from other permlttmg agencIes such as FDOT, PBC, SEWMD, DERM, L WDD, DEP and others, shall be mcluded with the permIt request" 15 On the SIte and civil plans, show the sidewalk through the drIveway with a bv1 minimum thIckness of 6 mches (CH. 23 Art. lIP). BUILDING DIVISION Comments. 16 Add to the buIldmg that is depicted on the drawmg tItled SIte plan (including buildmg labeled Alternate A) a labeled symbol that identIfies the locatiOn of the handIcap accessible entrance doors to the each tenant space of each DEPARTMENTS buIlding. INCLUDE REJECT 17 On both floor plan drawings, add a labeled symbol that Identifies the location of the handicap accessible entrance door to each tenant space. The locatIOn of the door(s) shall match the locatIOn of the accessible entrance doors that are depicted on the sIte plan drawmg, mcludmg Alternate A footpnnt drawmg. 18 Add a labeled symbol to the site plan that represents and delIneates the path of travel for the accessible route that IS reqUIred between the accessible parking spaces and the accessible entrance doors to each tenant space Add the accessible route to the footprint of Alternate A buIldmg. The symbol shall start at the accessible parkmg space(s) and terminate at the accessible entrance door to each tenant space The symbol shall represent the locatIOn of the path of travel, not the locatIOn of the detectable warning or other pavement markmgs that are reqUIred to be mstalled along the path. Identify on the plan the width of the accessible route that is located adjacent to the building (note' the mmimum width reqUIred by the code is forty-four (44) inches). Add text to the drawing that would mdIcate the symbol represents the accessible route and the route is deSIgned m complIance with Section 4.3 (Accessible Route) and 46 (Parkmg and Passenger Loadmg Zones) of the Flonda AccessibilIty Code for BUIldmg ConstructIOn. Please note that at time of permIt review the applIcant shall provide detaIled documentation on the plans that wIll venfy that the accessibIlity route IS m compliance WIth the regulations specIfied m the Florida AccessibilIty Code for BUIldmg Construction. ThIS documentatIOn shall mclude, but not be lImIted to, provIdmg fimsh grade elevatIOns along the path of travel. 19 Verify that the 14.5' proposed fimsh floor elevation IS in complIance WIth regulations of the code by addmg specIfications to the sIte data that address the followmg Issues [Section 3107 1.2, Chapter 31 of the Boynton Beach amendments to the 1997 edItion of the Standard Buildmg Code] a. The deSIgn professIOnal-of-record for the project shall add the followmg text to the sIte data. "The proposed floor elevation _NGVD IS above the hIghest 100-year base flood elevation applIcable to the buildmg sIte, as determmed by the South Florida Water Management DIstrict's surface water /l _ management constructIOn development regulatIOns." () '1\ V b Identify the floor elevatIOn that the deSIgn professIOnal has \" establIshed for the buildmg withm the footprmt ofthe buildmg ____ ~:......L nn the sIte plan, floor plan and CIvIl plan. ( ~rovide wntten venficatIOn that w:'~ ~Iewing area to ~/ ~xtend into Tract "H" (dramage track) The wntten verification snau ot: from the entity that controls the drainage easement as describe on the plat drawmg that IS reference on the survey that was submItted. 21 IndIcate, withm the footprmt of the bUIldmg that IS shown on the site plan, the number of stones that are m the buildmg mcludmg mezzanmes, where applIcable DImension the overall heIght of the bUIlding on the elevatIOn VIew drawmg of the buildmg. Facsimile TRANSMITTAL CITY OF BOYNTON BEACH 100 E. BOYNTON BEACH BOULEVARD POBOX 310 BOYNTON BEACH, FLORIDA 33425-0310 FAX. (561) 742-6259 PLANNING AND ZONING DIVISION to fax # date from re Winston Lee 561-74&-81:29 Au ust 4 2000 Lusia Galav uantum Park - Lots 21 & 218 Please find attached the first review comments for your project. To stay on the current review schedule, please do the following steps listed below, and bring all documents to the TRC scheduled for August 22, 2000 1 Revise your plans incorporating all comments listed herein, including the addition of notes on plans to confirm response to general statements/ comments, and bring 10 copies to the TRC review meeting (full sets including all pages originally submitted), 2. Submit the additional information as requested within the attached comments, (i e traffic analysis, engineering certification, etc.) 3 Prepare a written response (7 copies) consisting of a list briefly summarizing how each comment has been addressed on the revised plans or with the supplemental information including location on the plans ( this promotes an expeditious 2nd review by staff and your project representatives during the TRC meeting ),and 4 Submit reductions (8 V2 X 11) for the proposed site plans, elevations and landscaping plan (this is required for the final report and public presentation) Planning and Zoning Division City of Boynton Beach Boynton Beach, Florida 33425 742-6260 Fax: 742-6259 The applicant should not attend a TRC (2nd review) until all documents have been revised and copied for staff review If plans will not be fully revised and brought to the scheduled TRC meeting, contact Lusia Galav in this office by the Thursday prior to the scheduled meeting date Projects deviating from the original schedule are eligible for review at subsequent meetings, which are held every Tuesday To reschedule, contact Blythe Williamson, by the Thursday prior to the Tuesday TRC meeting that you desire to attend The remainder of the review schedule will be adjusted accordingly If you have questions on the attached comments, please contact the respective reviewer using the attached list of TRC representatives. If the plans are reasonably complete and all significant comments are addressed following TRC (2nd review), the project is forwarded to the Planning and Development Board Meeting that falls approximately 2 to 3 weeks following the TRC meeting An "*,, by any comment identifies a comment that must be addressed prior to moving forward to the Planning and Development board Note Items recognized by staff as typically outstanding at this point include a traffic report and/or confirmation of the traffic concurrency approval from the Palm Beach County drainage certification by a licensed engineer, signed "Rider to Site Plan Application" form and colored elevations of the proposed project. This information is necessary for the project to proceed If you have submitted this information, please disregard this note. Engineering John Guidry H David Kelley Jr 742-6496 742-6285 Building Don Johnson Mike Haag 742-6352 742-6357 Fire Department Steve Gale Bob Borden 742-6602 742-6345 Police Department Marshall Gage Officer John Huntington 737-3136 742-6185 Officer Louie Zeitinger Utilities John Guidry H David Kelley Jr 742-6496 742-6285 Public Works Larry Quinn Mark Lips 742-3208 742-6211 Parks & Recreation John Wildner Barbara Meacham 742-6227 742-6233 Forester/Environment Kevin Hallahan Kevin Hallahan 742-6267 742-6259 a list Planning & Zoning Michael W Rumpf, Lusia Galav 742-6262 742-6259 CHAIRMAN nSHRDA T A IPlanninglSHAREDI WPIPROJECTSIQuantum Park LoI 21 & 21 BI] 51 Review comments to applicant.doc rt REVIEW New SIte Plan PrOject name Quantum Park Lots 21 & 21B File number' NWSP 00-011 Reference 1st review plans consist of 12 sheets Identified as New Site Plan. File # NWSP-00-011 with a Julv 12 2000 Planning and ZOnIng Deoartment date stamo markmg , DEPARTMENTS INCLUDE REJECT PUBLIC WORKS Comments. NONE UTILITIES Comments GENERAL COMMENTS I Palm Beach County Health Department permits may be reqUIred for the water and sewer systems serving thiS project (CODE Sec. 26-12) Direct sanitary service connectIOn to the manhole IS not permitted. Either add an extension to the main line to accommodate the proJect's proposed wastewater service, or msert a lateral "wye" mto the eXlstmg hne a minImum of 5 feet m front of the manhole (which may put your lateral onto the adjacent property) 2. Fire flow calculatIOns wIll be reqUIred demonstratmg the City Code reqUIrement of 1,500 g.p.m. as stated in LDR Chap 6, Art. IV, Sec 16, or the reqUIrement Imposed by msurance underwnters, whichever IS greater (see CODE Sec 26-16(a)). 3 CODE Sec. 26-34(E) requires that a capacity reservatIOn fee be paid for thiS project either upon the request for the Department's signature on the Health Department applicatIOn forms or wlthm 30 days of site plan approval, whichever occurs first. ThiS fee Will be determmed based upon final meter Size, or expected demand. SPECIFIC CONDITIONS 4 Water and sewer lines to be owned and operated by the City shall be included Within utility easements. The easement shall be dedicated via separate mstrument to the City as stated m CODE Sec 26-33(a) 5 This office wIll not reqUIre surety for mstallation of the water and sewer utIlities, on conditions that the systems be fully completed, and given to the City UtIhtIes Department before the first permanent meter IS set. Note that settmg of a permanent meter is a prerequisite to obtammg the Certificate of Occupancy FIRE 6 A fire hydrant flow test IS reqUIred (LDR 6-16) DEPARTMENTS INCLUDE REJECT 7 Access road and hydrant will be m place pnor to above grade construction. POLICE Comments 8 "Right Turn Only" sign to be placed at dnveway eXit onto Gateway Blvd. Traffic flow for parking lot not shown. ENGINEERING DIVISION Comments. 9 On the civIl plan, add the general note that the stnpmg, markmgs and slgnage shall conform to City standard drawmg B-98001 Correct the typical H/C parkmg stall detaIl on the site plan details 10 On the site and cIvil plans, change the egress arrow markmg to a nght turn only arrow Add a "nght turn only" post sign to the stop sign and a one-way arrow sign m the median. Also, add double yellow lane separatIOn stnpes at thee entrance (CH. 4, Section 7B) 11 It is recommended that m heu of a stop sign/bar at the crosswalk, a "Yield to pedestnan" sign be used for more efficient traffic circulatIOn. 12 On the cIvil plans, add a general note that the dramage system shall conform to city standard drawmg B-91 007 13 It is recommended that curb cuts be placed m the contmuous curb for the 5 parkmg spaces opposite buildmg entrance to direct storm water mto the landscape area. 14 Add a followmg general note on the site plan. "All plans submitted for specific permits shall meet the City's code reqUIrements at time of apphcatIon. These permits mclude, but are not hmited to the followmg: site hghting, paving, drainage, curbmg, landscaping and lITigation. Permits reqUIred from other permIttmg agencies such as FDOT, PBC, SEWMD, DERM, L WDD, DEP and others, shall be mcluded With the permit request" 15 On the site and Civil plans, show the Sidewalk through the driveway With a minImum thickness of 6 inches (CH. 23 Art. lIP). BUILDING DIVISION Comments. 16 Add to the bUlldmg that IS depicted on the drawmg titled site plan (including bUIlding labeled Alternate A) a labeled symbol that Identifies the locatIOn of the handICap accessible entrance doors to the each tenant space of each DEPARTMENTS bUlldmg. INCLUDE REJECT 17 On both floor plan drawmgs, add a labeled symbol that Identifies the location of the handicap accessible entrance door to each tenant space. The location of the door(s) shall match the locatIOn of the accessible entrance doors that are depicted on the site plan drawmg, including Alternate A footpnnt drawmg. 18 Add a labeled symbol to the site plan that represents and delineates the path of travel for the accessible route that IS reqUIred between the accessible parking spaces and the accessible entrance doors to each tenant space Add the accessible route to the footpnnt of Alternate A buildmg. The symbol shall start at the accessible parkmg space(s) and term mate at the accessible entrance door to each tenant space. The symbol shall represent the location of the path of travel, not the location of the detectable warnmg or other pavement markmgs that are reqUIred to be mstalled along the path. Identify on the plan the Width of the accessible route that IS located adJacent to the buildmg (note the minImum Width reqUIred by the code IS forty-four (44) inches) Add text to the drawing that would mdlcate the symbol represents the accessible route and the route is designed m comphance with Section 4.3 (Accessible Route) and 46 (Parking and Passenger Loadmg Zones) of the Flonda Accessibility Code for Building Construction. Please note that at time of permit review the applicant shall provide detaIled documentatIOn on the plans that Will venfy that the accessibihty route IS m comphance With the regulatIOns specified m the Flonda AccessibIlity Code for BUlldmg Construction. This documentation shall mclude, but not be hmlted to, providmg finIsh grade elevations along the path of travel. 19 Venfy that the 14.5' proposed finIsh floor elevatIOn IS m comphance With regulatIOns of the code by addmg specificatIOns to the site data that address the followmg Issues [Section 3107 1.2, Chapter 31 of the Boynton Beach amendments to the 1997 edition of the Standard BUlldmg Code] a. The deSign professional-of-record for the proJect shall add the followmg text to the site data. "The proposed floor elevation NGVD is above the highest 100-year base flood elevation applIcable to the bUlldmg site, as determmed by the South Flonda Water Management District's surface water management construction development regulatIOns." b Identify the floor elevatIOn that the deSign profeSSional has estabhshed for the bUlldmg withm the footprint of the buildmg that IS shown on the site plan, floor plan and Civil plan. 20 ProVide wntten venficatlOn that would allow the protected vlewmg area to extend into Tract "H" (dramage track). The written verification shall be from the entity that controls the dramage easement as describe on the plat drawmg that is reference on the survey that was submitted. 21 Indicate, withm the footpnnt of the bUlldmg that is shown on the site plan, the number of stones that are m the bUlldmg mcludmg mezzanInes, where applicable Dimension the overall height of the buildmg on the elevatIOn view drawmg of the bUlldmg. I DEPARTMENTS l INCLUDE I REJECT I 22. On all floor plan drawmgs, mdlcate wlthm the footpnnt of the bUlldmg the number of stories that are m the bUlldmg mcludmg, where applicable, mezzanInes. 23 The building plans are not being revised for compliance with the applicable buildmg codes. Therefore, add the words "Conceptual Floor Plan" below the drawmgs titled Floor Plan found on both sheets Identified as A-4 Renumber one of the sheets. 24 Indicate on the floor plan drawing (17,579-sq ft. plan), wlthm the floor area, the proposed use of the structure. PARKS AND RECREATION Comments. NONE FORESTER/ENVIRONMENT ALIST Comments 25 The applIcant had addressed preservatIOn and relocatIOn of all the deSirable trees on the site. PLANNING AND ZONING Comments. 26 Revise the apphcatIon and plans to clarify the use ofbuildmg alternate 'A' Currently the plans show the use of both buildmgs. The site plan shows one buildmg type and the CivIl drawmgs show the use ofbUlldmg alternate 'A' Submit a wntten Justification and traffic report describmg the proposed use of alternate buildmg 'A' In the justificatIOn describe when and why the alternate buildmg would apply As discussed m the pre-apphcatlon meetmg, a phased plan was to be submitted which utlhzed the 15,292 sf bUlldmg. Submitted plans mdlcate no phases and the use of the 17, 579 sf. buildmg. If the plans are reviewed and approved utIlIzmg the larger buildmg, any revisions regarding the use of the alternate bUlldmg Will reqUIre the modificatIOn of the site and landscape plans of record ( Ch.4, Sec 7 Par.B 1) 27 ReVise the survey to include the 40' dramage easement located along the north property line ( Ch.4, Sec 7, Par.A.3) 28 ReVise the site plan to mdlcate the correct buildmg heights as they relate to the architectural plans. Correct architectural plans to show overall buildmg height dimensIOns. Clanfy the site plan data to mdlcate the correct height mformatlOn for both bUIlding options (Ch.4, Sec 7, Par.B 1). 29 On the landscape plan, revise the plant hst to include a plant matenal related to the CL plant tag found at the southwest corner of the site (Ch.4, Sec.7, DEPARTMENTS INCLUDE REJECT Par C 1) 30 Submit a copy of the waiver reqUIred by FPL to place the monument sign and large palms wlthm their 15' underground utIhty easement. 31 On the landscape plans, provide the appropnate vegetative screen around the dumpster enclosure (Ch. 7 5, Art.II, Sec.5, Par.J) MWR/blw J:\SHRDATA\PLANNINGISHARED\WPIPROJECTS\QUANTUM PARK LOT 21 & 21BI1ST REVIEW COMMENTS.DOC DEPARTMENT OF DEVELOPMEN1 MEMORANDUM NO PZ 00-210 TO TRC MEMBERS Bob Borden, Deputy Fire Marshal Kevin Hallahan, Forester/Environmentalist Louie Zeitinger Police Department John Huntington, Police Department H David Kelley Utilities Department Michael Haag, Building Division Larry Quinn, Public Works Department Barbara Meacham, Parks Division H David Kelley, Engineering Department o Iff iti PLAt,,;--- ____ZON!!,;!, ~ i ! -.; ---1 FROM Michael W Rumpf Director of Planning and Zoning '--""-- DATE. July 18 2000 RE SITE PLAN REVIEW PROCEDURES 1 ST Review Project - Quantum Park - Lots 21 & 21 B Location - North Side of Gateway Blvd, east of adjacent to the L.W D D E-4 Canal Agent - Winston Lee, Winston Lee & Associates File No - NWSP 00-011 Find attached for your review the plans and exhibits for the above-referenced project. Please review the plans and exhibits and transmit formal written comments or e-mail to Blythe Williamson and I no later than 5.00 P.M. on Tuesdav Auaust 1st, 2000. When preparing your comments, please separate them into two categories, code deficiencies with code sections referenced and recommendations that you believe will enhance the project. Adhering to the following review guidelines will promote a comprehensive review and enable the applicant to efficiently obtain Technical Review Committee approval 1 Use the review standards specified in Part IV, Land Development Regulations, Site Plan Review and the applicable code sections of the Code of Ordinances to review and formulate comments 2 The documents submitted for the project were determined to be substantially complete with the exception of traffic data, however, if the data provided to meet the submittal requirements is insufficient to properly evaluate and process the project based on the review standards or the documents show code deficiencies, additional data and/or corrections should be requested by the reviewer by contacting Lusia Galav or myself 3 Each comment shall reference the section of the code that is incorrectly depicted on the documents Page 2 4 Technical Review Committee member(s) shall identify in their comments when the plans depict or when the location and installation of their departmental required improvements may conflict with other departmental improvements 5 When a TRC Member finds a code deficiency that is outside of his/her review responsibility, the comment and the specific code section may be included in their review comments with the name of the appropriate TRC Member that is responsible for the review specified 6 If a TRC member finds the plans acceptable, he/she shall forward a memorandum, within the time frame stated above, to me The memorandum shall state that the plans are approved and that they do not have any comments on the plans submitted for review and that they recommend the project be forwarded through the approval process All comments shall be typed, addressed and transmitted or e-mailed to Blythe Williamson and I for distribution to the applicant. Please include the name and phone number of the reviewer on this memorandum or e-mail Lusia Galav will be the Planning and Zoning staff member coordinating the review of the project. First review comments will be transmitted to the applicant along with a list of Technical Review Committee (TRC) members MWR. blw Attachment XC Steve Gale, Fire Marshal Marshall Gage, Police Department John Guidry, Utilities Director and Interim Director of Engineering Don Johnson, Building Division Christine Roberts, Director of Public Works Central File J:ISHRDATAIPlanningISHAREDIWPIPROJECTS\Quantum Park Lol 21 & 2181151 Review Plans Memo.doc DEPARTMENT OF DEVELOPMENT BUILDING DIVISION MEMORANDUM NO 00-221 TO Michael Rumpf, DIrector of Plannmg and Zomng DATE July 27, 2000 W~&nw~m fLI Quantum Park Lots 21 & 21B - New Site Plan (NWSP 9-011) PLA-~~ViNZ~ I Ist review comments ZONING DEPT FROM. Michael E. Haag, BUlldmg Code Admlmstrator RE We have revIewed the plans for the above-referenced project. The applIcant must acknowledge and address the below lIsted comments before the BUlldmg DIvIsIOn wIll recommend that the project be presented to the Board for then reVIew Buildine: Division (Permit & Site Specific Comments) - Michael E. Haag (561) 742-6352 I Add to the bUlldmg that IS depIcted on the drawmg tItled site plan (includmg bUlldmg labeled Alternate A) a labeled symbol that IdentIfies the locatIOn of the handicap accessible entrance doors to the each tenant space of each bUlldmg. 2. On both floor plan drawmgs, add a labeled symbol that Identifies the location of the handIcap accessible entrance door to each tenant space. The locatIOn of the door(s) shall match the locatIOn of the accessible entrance doors that are depicted on the site plan drawmg, mcludmg Alternate A footpnnt drawmg. 3 Add a labeled symbol to the site plan that represents and delIneates the path of travel for the accessible route that IS reqUIred between the accessible parkmg spaces and the accessible entrance doors to each tenant space Add the accessible route to the footpnnt of Alternate A bUlldmg. The symbol shall start at the accessible parkmg space(s) and temllnate at the accessible entrance door to each tenant space The symbol shall represent the locatIOn of the path of travel, not the locatIOn of the detectable warmng or other pavement markmgs that are reqUIred to be mstalled along the path. IdentIfy on the plan the Width of the accessible route that IS located adjacent to the bUlldmg (Note The mmlmum Width reqUIred by the code IS forty-four (44) mches) Add text to the drawmg that would mdlcate that the symbol represents the accessible route and the route IS deSigned m comphance With SectIOn 4.3 (Accessible Route) and 46 (Parkmg and Passenger Loadmg Zones) of the Flonda AccessibilIty Code for BUlldmg ConstructIOn. Please note that at tIme of permIt review the applIcant shall provIde detailed documentatIOn on the plans that Will venfy that the accessible route IS m complIance With the regulatIOns speCIfied m the Flonda AccessibilIty Code for BUlldmg ConstructIOn. ThIS documentatIOn shall mclude, but not be lImited to, provldmg fimsh grade elevatIOns along the path of travel. DEPARTMENT OF ENGINEERING MEMORANDUM NO 00-114 TO Michael Rumpf, DIrector of Plannmg and zonm~ ~ ^ / John A. GUidry, Intenm DIrector of Engmeenng ~ V; H. DaVid Kelley, Jr, PE/PSM, Clvil/UtilIty Engmeef\1' THRU FROM. DATE July 28, 2000 LOTS 21 AND 21B QUANTUM PARK SITE PLAN - 1 ST REVIEW FILE # NWSP 00-011 RE. 1 On the cIvIl plan, add the general note that the stnpmg, markmgs and slgnage shall conform to city standard drawmg B-98001 Correct the typical H/C parkmg stall detail on the site plan details. 2 On the SIte and CIVIl plans, change the egress arrow markmg to a nght turn only arrow Add a "nght turn only" post sign to the stop SIgn and a one-way arrow sign m the median. Also, add double yellow lane separatIOn stnpes at the entrance. CH 4, SectIOn 7B 3 It IS recommended that m lIeu of a stop slgnlbar at the crosswalk, use a "Yield to pedestnan sign for more effiCIent traffic cIrculatIOn. 4 On the CIvIl plans, add a general note that the dramage system shall conform to city standard drawmg B-91 007 5 It IS recommended that curb cuts be placed m the contmuous curb for the 5 parkmg spaces opposite bUIldmg entrance to dIrect storm water mto the landscape area. 6 Add a general note on the site plan that, "All plans submItted for specific permits shall meet the City's code reqUirements at time of applIcatIOn. These permits mclude, but are not lImited to the followmg site lIghtmg, pavmg, dramage, curbmg, landscapmg and IrrIgatIOn. PermIts reqUired from other permlttmg agencies such as FOOT, PBC, SEWMD, DERM, L WDD, DEP and others, shall be mcluded With the permit request." 7 On the site and CIVil plans, show the Sidewalk through the dnveway WIth a minImum thIckness of 6 mches. CH 23 ART II P S '\Engineering\Engineering Dept. Memorandum.doc CITY OF BOYNTON BEACH, FLORILA INTER-OFFICE MEMORANDUM TO' Michael W Rumpf DATE Dlr of Planmng & Zomng 7/27/00 FILE NWSP-OO-O 14 FROM. Off LoUIs J Zeltmger Off John Huntmgton Pohce Department Cnme PreventIOn UnIt SUBJECT REFERENCES ENCLOSURES I have viewed the above bUlldmg plans and have the followmg comments. 1 "RIght Turn Only" sign to be placed at dnveway eXit onto Gateway Blvd. Traffic flow for parkmg lot not shown. TO DEP ARTMENT OF DEVELOPMENT BUILDING DIVISION MEMORANDUM NO 00-221 FROM. DATE RE We have reviewed the plans for the above-referenced proJect. The applIcant must acknowledge and address the below lIsted comments before the BUlldmg DIVISion will recommend that the project be presented to the Board for their review Buildine Division (Permit & Site Specific Comments) - Michael E. Haae (561) 742-6352 1 Add to the bUlldmg that IS depIcted on the drawmg tItled sIte plan (mcludmg bUlldmg labeled Alternate A) a labeled symbol that Identifies the locatIOn of the handIcap accessible entrance doors to the each tenant space of each bUlldmg. 2. On both floor plan drawmgs, add a labeled symbol that IdentIfies the locatIon of the handicap accessible entrance door to each tenant space. The locatIOn of the door(s) shall match the location of the accessible entrance doors that are depIcted on the sIte plan drawmg, mcludmg Alternate A footpnnt drawmg. 3 Add a labeled symbol to the site plan that represents and delmeates the path of travel for the accessible route that IS reqUIred between the accessible parkmg spaces and the accessible entrance doors to each tenant space Add the accessible route to the footpnnt of Alternate A bUlldmg. The symbol shall start at the accessible parkmg space(s) and termmate at the accessible entrance door to each tenant space The symbol shall represent the locatIOn of the path oftravel, not the locatIon of the detectable warnmg or other pavement markmgs that are reqUIred to be mstalled along the path. Identify on the plan the Width of the accessible route that IS located adjacent to the bUlldmg (Note The mmlmum Width reqUIred by the code IS forty-four (44) mches) Add text to the drawmg that would mdlcate that the symbol represents the accessible route and the route IS deSigned m complIance With SectIOn 43 (Accessible Route) and 46 (Parkmg and Passenger Loadmg Zones) of the Flonda AccessibilIty Code for BUlldmg ConstructIOn. Please note that at tIme of permIt review the applIcant shall prOVIde detaIled documentation on the plans that Will venfy that the accessible route IS m complIance With the regulatIOns speCified m the Flonda AccessibilIty Code for BUlldmg Construction. ThIS documentatIOn shall mclude, but not be lImited to, provldmg fimsh grade elevatIOns along the path of travel. BUlldmg DIVISion Memo No 00-221 to Michael Rumpf RE Quantum Park Lots 21 & 21B - New Site Plan - 1 st review comments July 27, 2000 Page Two 4 Venfy that the 145' proposed fimsh floor elevatIon IS m comphance With regulatIOns of the code by addmg specIficatIOns to the sIte data that address the followmg Issues [SectIOn 3107 1.2, Chapter 31 of the Boynton Beach amendments to the 1997 edItIon of the Standard BUlldmg Code] a) The design professIOnal-of-record for the project shall add the followmg text to the site data. "The proposed floor elevatIon _ _ NGVD IS above the highest 100-year base flood elevatIOn applIcable to the bUlldmg site, as determmed by the South Flonda Water Management DIstnct's surface water management constructIOn development regulatIOns. " b) IdentIfy the floor elevatIOn that the desIgn professIOnal has estabhshed for the bUlldmg wlthm the footpnnt of the bUlldmg that IS shown on the SIte plan, floor plan and CIVil plan. 5 PrOVide wntten venficatIOn that would allow the protected vlewmg area to extend mto Tract "H" (dramage track) The wntten venficatIOn shall be from the entity that controls the dramage easement as described on the plat drawmg that IS referenced on the survey that was submitted. 6 Indicate, wlthm the footpnnt ofthe bUlldmg that IS shown on the site plan, the number of stones that are m the bUlldmg mcludmg, where apphcable, mezzanmes. Add to the site data the number of stones m the bUlldmg mcludmg IdentIfymg mezzamnes, where apphcable DimensIOn the overall heIght of the bUlldmg on the elevatIOn view drawmgs of the bUlldmg. 7 On all floor plan drawmgs, mdlcate wlthm the footpnnt of the bUlldmg the number of stones that are m the bUlldmg mcludmg, where apphcable, mezzanmes. 8 The bUlldmg plans are not bemg reviewed for comphance with the applIcable bUlldmg codes. Therefore, add the words "Conceptual Floor Plan" below the drawmgs tItled Floor Plan found on both sheets Identified as A-4 Renumber one of the sheets. 9 Indicate on the floor plan drawmg (17,579-sq ft. plan), wlthm the floor area, the proposed use of the structure MEH bg J \SHRDA TA\Development\Building-6870\Documents\TRC\:\WSP 00-011 1st review Quantum Park-lots 21 & 21Rdoc ~ PUBLIC WORKS DEPARTMENT MEMORANDUM #00-119 TO Mike Rumpf, Director of Planmng & Zomng VIA. Chnstme Roberts, Intenm PublIc Works Director ~ FROM Mark A. Lips, Forman III DATE July 21, 2000 SUBJECT 1 st Review - Site Plan Review Procedures Project - Quantum Park - Lots 21 & 21B Location - North Side of Gateway Blvd., east of adjacent to the L W.D.D E-4 canal Agent - Winston Lee, Winston Lee & AssocIates FIle No - NWSP 00-011 The PublIc Works Department has no comments or ObjectIOns to thIS project gomg forward. If you have any questIOns please contact me at (561) 742-6200 ... -:7il~ I ML/dc Attachment LEISURE SERVICES. PARKS MEMORANDUM #00-103 TO Michael Rumpf, Director of Planmng & Zomng John Wildner, Parks DIrector r Barbara J Meacham, Parks & Landscape Planner THRU FROM ./ RE Review of Boynton Shoppes, Quantum Park-Lots 21 & 21B, and Lot 50-B Quantum Corporation Park, Park Ridge Blvd. Date July 28, 2000 The Parks DIVISIon has revIewed the plans and exhibIts for the aforementIOned projects and has no comments. DEPARTMENT OF UTILITIES MEMORANDUM NO 00-163 TO THRU Michael W Rumpf, Director of p~in/nd Zoning John A. Guidry, Utilities Director ~ ~ H. DavId Kelley, Jr., PE/PSM, Uitlhty Engmeer t9 FROM. DATE July 28, 2000 QUANTUM PARK - LOTS 21 & 21B - 1 st REVIEW FILE NO NWSP 00-011 RE We offer the followmg comments on the above noted proJect: GENERAL COMMENTS 1) Palm Beach County Health Department permits may be reqUired for the water and sewer systems servIng thiS project (CODE Sec 26-12) DIrect sanitary service connectIOn to the manhole IS not permitted. Either add an extensIOn to the mam lIne to accommodate the project s proposed wastewater serVice, or Insert a lateral "wye" mto the eXlstmg hne a mmlmum of 5 feet In front of the manhole (which may put your lateral onto the adjacent property) 2) FIre flow calculatIOns wIll be reqUired demonstratmg the City Code reqUirement of 1,500 g.p.m. at stated m LDR Chap 6, Art. IV, Sec. 16, or the reqUirement Imposed by msurance underwnters, whichever IS greater (see CODE Sec. 26-16(a)) 3) CODE Sec 26-34(E) reqUires that a capacity reservatIOn fee be paid for thiS project either upon the request for the Department's signature on the Health Department apphcatlOn forms or wlthm 30 days of site plan approval, whichever occurs first. ThiS fee WIll be determmed based upon final meter Size, or expected demand. SPECIFIC CONDITIONS 4) Water and sewer hnes to be owned and operated by the CIty shall be mcluded wIthm utIlIty easements. The easements shall be dedicated Via separate mstrument to the CIty as stated In CODE Sec 26-33(a) 5) ThiS office Will not reqUire surety for mstallatlOn of the water and sewer utIhtIes, on condItIons that the systems be fully completed, and given to the City UtIlities Department before the first permanent meter IS set. Note that settmg of a permanent water meter IS a prereqUisite to obtammg the Certificate of Occupancy S'\Engineering\Engineering Dept. Memorandum.doc FIRE & LIFE SAFETY DIVISION Memorandum No 2000-100 @,.. ,~ .' ,.- '," NFPA Life Safety Code 101, National Fire Code 1, all applicable National Fire Protection Association codes, and the City Fire code shall be adhered to TO Mike Rumpf, Director Planning & Zoning FROM Steve Gale Fire Marshal DATE July 19, 2000 SUBJECT Quantum Park Lots 21 & 21B NWSP 00-011 A fire hydrant flow test is required LOR 6-16 Access road and hydrant will be in place prior to above grade construction This plan may go forward with above comments cc File Faxed to Blythe Williamson FIRE & LIFE SAFETY DIVISION Memorandum No 2000-100 NFPA Life Safety Code 101, National Fire Code 1, all applicable National Fire Protection Association codes, and the City Fire code shall be adhered to TO Mike Rumpf, Director Planning & Zoning FROM Steve Gale Fire Marshal DATE July 19, 2000 SUBJECT Quantum Park Lots 21 & 21B NWSP 00-011 A fire hydrant flow test is required LDR 6-16 Access road and hydrant will be in place prior to above grade construction This plan may go forward with above comments cc File Faxed to Blythe Williamson Parks I Planning Division Memorandum- TRC To Mike Rumpf, DIrector of Plannmg and Zomng From. Kevm J Hallahan, Forester I EnvIronmentalIst kJ/f Subject: Quantum Park, Lots 21-21B NWSP - 00- 011 Date July 24, 2000 The applIcant has addressed preservatIon, and relocatIOn of all of the desIrable trees on the sIte. The project should contmue m the normal review process. Kjh File