REVIEW COMMENTS
DEPARTMENT OF DEVELOPMENT
MEMORANDUM NO PZ 00-156
TO
FROM
Bob Borden, Deputy Fire Marshal
Larry Quinn, Public Works
Mike Haag, Building Division
Kevin Hallahan, Forester/Environmentalist
H David Kelley Jr , Utilities Department
John Huntington, Police Department
Louie Zeitinger, Police Department
H David Kelley Jr , Engineering Department
Barbara Meacham, Parks Division
Lusia Galav, Planning ~nd Zoning Department
Michael W Rumpf~l~ Planning and Zoning
DATE
June 1, 2000
SUBJECT
Rectified Plans for -Quantum Business Center (Lots 32-38)
NWSP-00-001
The amended plans for Quantum Business Center (Lots 32-38), New Site Plan have been
submitted for final sign-off by the Technical Review Committee Four (4) sets of plans, each
requiring your unconditional signature, are available for review in Planning and Zoning A copy
of the originally reviewed plans, staff comments and development order are available for your
use to perform the review
Please review and sign-off each of the four- (4) sets of plans, NO LATER THAN 5:00 P.M.,
June 11, 2000 If the plans are not in compliance with your staff comments or City regulations,
do not sign the plans but only indicate the memorandum number where your comments are
documented To facilitate the sign-off process, please resubmit written comments addressed to
the Planning and Zoning Director, NO LATER THAN 5'00 PM., June 11, 2000
Thank you for your prompt response to this request.
MWR.bw
cc Steve Gale, Deputy Fire Chief
Marshall Gage, Police Chief
John Guidry, Utilities Director
John Wildner, Parks Department
J:ISHRDATAIPlanningISHAREDlWPIPROJECTSIQUANTUM 2000IABANIQuantum Business Center (32-38) rectified memo.doc
DEVELOPMENT DEPARTMENT
MEMORANDUM NO PZ 00-066
SITE PLAN REVIEW STAFF REPORT
PLANNING AND DEVELOPMENT BOARD AND CITY COMMISSION
April 4, 2000
DESCRIPTION OF PROJECT
Project Name/No Quantum Business Center (Lots 32-38}/NWSP 00-001
Property Owner' BGllndustries, Inc.
Applicant/Agent: Premier Asset Management/Winston Lee Winston Lee & Associates, Inc.
Location Lots 32, 33, 34A, 34B, 35, 36, 37, and 38 Quantum Industrial Park
Land Use/Zoning' Industrial/Planned Industrial Development (PID)
Type of Use Industrial (speculative warehouse buildings with office space)
Project size
Site Area
Building Area
2357 acres (1,026625 square feet)
Buildino 1 -
142,202 square feet: 115,1836 (warehouse), 27,0184 (office)
BuildinQ 2 -
99,750 square feet: 80,7975 (warehouse), 18,952.5 (office)
BuildinQ 3 -
94,098 square feet: 76,21938 (warehouse); 1787862 (office)
Total- 336,050 square feet: 272,20048 (warehouse), 63,849 52 (office)
Adjacent Uses
(see Exhibit "A" - Location Map)
North - Lot 93 Quantum Park zoned PID (preserve),
South - Gateway Boulevard, farther south Tract "0" - water management;
East Tract "J" Quantum Park zoned PIO and vacant land zoned R1-AAA, and
West - Quantum Boulevard
Site Characteristics The subject vacant parcels within the Quantum Park PID contain various trees and
undergrowth characteristic of disturbed scrub habitat. The survey identified various existing
species predominantly including Slash Pine, Scrub Oak, Live Oak, Sand Pines and Pink
Trumpet Trees
Proposal. The developer proposes the construction of three (3) separate speculative warehouse
buildings with ancillary office space totaling 336,050 square feet on approximately 24
acres The project is to be constructed in one phase and broken down as follows' Building
#1, 142,202 square feet, Building #2, 99 750 square feet, and Building #3 94,098 square
feet. Each building would consist of approximately 20% office space with the remaining
space devoted to warehousing designed in concert with a single fa9ade of multiple loading
bay doors oriented north, south or east so as not to directly face Gateway Boulevard or the
private roadway Quantum Boulevard (see Exhibit "B" - Proposed Site Plan)
Concurrency'
a. Traffic - A traffic statement for this project was submitted and approved by the Palm Beach
County Traffic Division
b Drainage - Conceptual drainage information was provided for the City's review The Engineering
Division is recommending that the review of specific drainage solutions be deferred
until time of permit review
Page 2
Quantum Business Center (Lots 32-38)- Site Plan Review Staff Report
Memorandum No PZ 00-066
Driveways There are six driveways proposed for this project, which is to be constructed on 8
developable lots assembled within this PID The PID zoning district limits a project to a
maximum of two driveways per each developable parcel If each of the eight parcels were
developed individually, rather than collectively, although unrealistic, there could be a total of
16 driveways constructed All four driveways proposed along Quantum Boulevard would
be aligned with existing median openings, and one of the two driveways proposed along
Gateway Boulevard would be placed adjacent to a median opening limiting the sixth
driveway to right-in right-out traffic circulation All but one driveway is proposed to be
approximately 32 feet wide, each to accommodate two lanes of traffic. The remaining
driveway is expanded in width (approximately 80 feet and 4 lanes wide) in order to
accommodate the majority of truck traffic entering and exiting the project. Numerous
driveways are proposed for this project principally to maximize identity for each of the three
buildings and to minimize conflicts between truck and vehicle traffic.
Parking Facility' The parking spaces required for this entire project, 554 spaces, have been tabulated based
on the ratio of 1 per 300 square feet of office space and 1 per 800 square feet of warehouse
space These standard ratios have been used to calculate the parking obligations, rather
than employee data as recommended by PID zoning regulations, due to the current lack of
employee information The project proposes to include a total of 558 spaces including a
total of 18 accessible spaces All spaces, except handicapped spaces, will be dimensioned
nine feet by sixteen and one-half feet (9' x 16 5') with a one and one-half (1 ~) foot
overhang The parking area design will meet the City's Land Development Regulations,
Chapter 2 - Zoning for warehouse and office uses, and the ADA requirements for this use
will be satisfied once all conditions regarding accessible path designation are met.
Landscaping The landscaping of the site will fully meet code requirements when staff comments are
incorporated Furthermore, landscaping enhancements are proposed including foundation
hedges and plantings ornamental berming and dense tree spacing intended to buffer views
to loading areas, and decorative corner treatments utilizing a collection of existing and new
species The perimeter buffer is required by the PID zoning regulations to be 40 feet wide
where a project abuts a residential zoning district, and 25 feet where it abuts other
commercial/industrial zoning districts I n 1 996, the city r ejected a request to a mend the
perimeter planting scheme and width for that portion of the perimeter buffer that abuts the
east side of the subject project, from 40 feet to 5 feet. The conditions of approval required
that subsequent requests to reduce the buffer be processed as a variance to the PID zoning
regulations The proposed project is shown to reduce the buffer by approximately 15 feet at
one point where the buffer turns 90 degrees to coincide with the property boundary
Although the reduction is minimal, it still conflicts with the PID zoning regulations The
project must be adjusted to avoid the encroachment or a variance must be received
Building and Site Building and site regulations will be fully met when staff comments are incorporated into the
permit drawings
Community Design The three (3) long rectangular-shaped buildings are proposed to be constructed from
concrete (tilt-up) walls The facades of each building will be enhanced with entry features
(front only) which consist of walls raised separate from the greater wall, Styrofoam moldings,
varied surface textures, medallion features, and with horizontal and circular scoring The
entry walls are proposed to be painted a tan color, while the greater portion of the walls
would be painted "Linen White" (e g cream) with trim and accents painted a light emerald
white
Page 3
Quantum Business Center (Lots 32-38)- Site Plan Review Staff Report
Memorandum No PZ 00-066
Signage
The project is proposed to include four (4) site signs, designed consistent with the Quantum
Park PID sign program, placed at four (4) of the six (6) project entrances.
RECOMMENDATION.
Staff recommends that this site plan request be approved, subject to the comments included in Exhibit "C" -
Conditions of Approval The Technical Review Committee (TRC) recommends that the deficiencies identified in
this exhibit be corrected on the set of plans submitted for building permit.
xc: Central File
J:\SHRDATA\Planning\SHAREDlWP\PROJECTS\QUANTUM 2000\LOTS 32 38\STAFF REPORT Lots 32-38.doc
1 st REVIEW COMMENTS
Project name QUANTUM BUSINESS CENTER (LOTS 32-38)
FIle number NWSP 00-003
Reference' 1st RevIew, FIle # NWSP 00-001 wIth a Januarv 1 L 2000 Plannmg and Zomng Department date
stamp markmg
I DEPARTMENTS I INCLUDE I REJECT I
PUBLIC WORKS
Comments
UTILITIES
Comments.
1 All UtIlItIes easements shall be shown on the rectIfied landscaping
drawmgs so that utIlitIes may determme whIch trees may mterfere wIth
utIlItIes In general, palm trees wIll be the only tree specIes allowed
wIthm utIlIty easements Canopy trees may be planted outsIde of the
easement so that roots and branches wIll not Impact those utIlItIes wIthm
the easement m the foreseeable future. LDR Sec 7.5-18 1 gIves publIc
utIlItIes the authonty to remove any trees that mterfere WIth utIlIty
servIces, eIther m utIlIty easements or publIc rights-or way
2 Dept. of Health permIts may be reqUIred for the water and sewer
systems servmg this project. (Sec 26-12)
3 FIre flow calculatIOns wIll be reqUIred demonstratmg the CIty Code
reqUIrement of 1500 g.p.m. as stated m LDR Chapter 6, ArtIcle IV,
SectIon 16, or the reqUIrement Imposed by msurance underwnters,
whIchever IS greater (see SectIon 26-16(a)). Please submIt these
calculatIOns WIth your Health Department permIt submittal
4 SectIOn 26-34(E) of the CIty Code reqUIres that a capacIty reservatIon
fee be paid for thIS project either upon my request for SIgnature on the
Health Dept. applIcatIon forms or WIthin 30 days of SIte plan approval,
whIchever occurs first. ThIS fee will be determined based upon final
meter SIzes, or expected demand.
5 Comp Plan polIcy 3C.3 4 reqUIres the conservatIon of potable water
CIty water may not, therefore, be used for IrngatIon where other sources
are readIly avaIlable
6 Water and sewer lInes to be owned and operated by the CItV shall be
mcluded wIthm utIlIty easements. The easements shall be dedicated VIa
separate instruments to the CIty as stated m Sec 26-33(a) of the Code
7 UtIlIty Department wIll not reqUIre surety for mstallation of the water
and sewer utIlItIes, on condItIon that the systems be fully completed, and
gIven to the CIty before the first permanent meter IS set. Note that
settmg of a permanent water meter IS a prereqUIsIte to obtainmg the
certIficate of occupancy
r~
Page 2
Quantum BusIness Center - Lots 32-38
File No NWSP 00-003
~
tJt0
DEPARTMENTS INCLUDE REJECT
8 LDR Chap 6, ArtIcle IV, Sec 16 reqUires that all points on each
bUildIng wIll be WIthIn 200 feet of an eXIstIng or proposed fire hydrant.
Please demonstrate that the plan meets thIS condItIon, by showing all
hydrants.
9 A bUildIng permIt for thIS project shall not be Issued untIl thIS office has
approved the plans for the water and/or sewer Improvements reqUired to
serve the project. (Sec 26-15)
10 The waste stream from all manufacturIng process must meet the CIty's
pretreatment reqUirements. A samplIng pOInt must be provIded to allow
mOnItonng of any waste stream. (Sec 26-143, 26-147)
( ~RE ) L /" ~A ~'t-- 7/f ,?- L ~6&z>
~ /
Comments :Sk>uJ F P C&Y}Y}ev/-'IPI} S
11 A fire flow test is reqUired pnor to constructIOn. LDR 6-16 /
~ Hydrants and access roads must be m tace pnor to above grade -/
constructIOn. NFP A 1 Md.l -h o~ hy a l~)\'-+~ fZ?~"', red -I", -
)'Ylee~~$:' rCld il.lS TC' q"j Frt
POLICE D -F ,- lM---+ tA-'( e
Comments
13 At thIS tIme there are no roadway markIngs or traffic flow pattern
markIngs. I do foresee a couple of problem areas that will need to be
addressed before final approval.
ENGINEERING DIVISION
Comments
14 On the SIte Plan add a general note that all plans submItted for speCIfic
permIts shall meet the CIty'S code reqUirements at tIme of applIcation.
These permIts Include, but are not lImIted to the follOWIng: sIte lIghtIng,
pavIng, draInage, curbIng, landscapIng and lITIgatIOn. PermIts reqUired
from other permIttIng agencIes, such as FDOT, PBC, SFWMD, DERM,
L WDD, DEP and any others, shall be Included WIth the permIt request.
15 Abandon that portIon of the recorded 10 foot utIlIty easement between
lots 32 & 33 to accommodate the new constructIOn
16 Abandon that portIon of the recorded 10 foot utIlIty easement between
lot 38 and lots 36 & 37 to accommodate the new constructIOn.
17 ProVIde a general note on sheet 4 of the pavIng and draInage plans that
the exfiltratIon system shall conform to CIty Standard Drawing B-91007
~
Page 3
Quantum Busmess Center - Lots 32-38
FIle No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
18 Any fill operatIOn shall reqUIre an excavatIOn/fill permit.
19 Show the dramage plan at the same scale as the sIte development plan.
[LDR Chapter 4, SectIOn 7.F ]
20 On the sIte and CIVil plans show the 5 foot concrete sidewalk through
both dnveways along Gateway Blvd. with a mmlmum thickness of 6"
[LDR Chapter 23, ArtIcle II.P]
21 On the site and CivIl plans add a general note that all striping, markings
and slgnage shall conform to City Standard Orawmg B-9l 007 and
reflect all stnpmg, marking and slgnage on both plans. [LDR Chapter 4,
SectIOn 7.B ]
22 Show proposed IIghtmg on both the landscape and CIVil plans for
mspectlOn purposes and possible shadmg of parkmg lot areas. [LDR
Chapter 4, SectIOn 7.B ]
23 On the site and landscape plans mdlcate the clear Sight tnangle for the
two Gateway Boulevard dnveways and at the Quantum Boulevard
mtersectlOn as specified m FDOT Index 546
24 On the site and landscape plans mdlcate the clear Sight tnangles along
the four Quantum Blvd. dnveways using the 35 foot legs of the tnangle
as specified m LOR Chapter 7.5, Article II, SectIOn 5.H.2
25 On the landscape plans add a general note that the landscapmg wlthm
the safe Sight tnangles shall have a clear, unobstructed cross-visibilIty
between 30 mches and 6 feet above the pavement. [LOR Chapter 7.5,
Article II, SectIon 5.H ]
26 On the site and CIVil plans show a five foot concrete Sidewalk along
Quantum Blvd. to the lImIts of the site or obtain a waiver therefrom.
[LOR Chapter 22, Article I, SectIOn 5 & Chapter 6, Article IV, SectIOn
lOt.]
27 Reduce the dnveways along Quantum Blvd. from four to two per code
or obtam a vanance therefrom [LDR Chapter 23, Article I, Section 3.B
& Article II.H.7 & LDR Chapter 2, Section 7.H.3 ]
28 On the site and CIVIl plans show the 5 foot handicap accessible paths
flush through the Sidewalks With a ramp up on eIther SIde per Flonda
AccessibilIty Code (8 places)
29 The maximum dnveway Width IS 32 feet. Obtam an approval for the
south dnveway along Quantum Blvd. [LOR Chapter 23, Article II.H.l ]
Page 4
Quantum Busmess Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
30 If a sidewalk IS reqUired along Quantum Blvd, then handicap assessible
paths should be shown through the landscaped areas gomg to the
sidewalk per Flonda Accessibility Code It IS recommended that there
be one for BUlldmg #2 and two for BUlldmg #3
31 On the cIvil plans provide cross-sectIOns of the followmg areas showmg
the elevatIOnal differences between the finIshed site and the abutting
properties
a. Lot 32 and the sand pme preserve to the north.
b Lots 32 & 33 along the water management Tract "J"
c Lots 34A & 34B along the unplatted parcel to the east
32 Remove the reference to a "tow away zone" on the handicap post sign.
See Standard Drawmg B-98001
33 On the pavmg and dramage plan Identify the 4 sheets on the locatIOn
map for reference purposes.
34 Specify a 12 mch minImum subgrade thickness on the "typical
pavement on Sheet 4 of 4 of the Civil drawmgs.
35 Correct the elevatIOn callouts ofBUlldmgs #1 & #2
36 Clarify use of eXlstmg 48mch CMP at BUlldmg #3
37 Show UnIty of Title for all 8 lots.
RECOMMENDA nONS
38 Locate the handicap post sIgn wlthm the landscape areas behmd the
Sidewalk.
39 In lieu of wheelstops and the asphalt between them and the 5 foot
SIdewalks along the buildmgs, construct 7 foot Sidewalks mcorporatmg
the edge of curb as a contmuous wheelstop This reduces mamtenance
and the potential tnppmg hazards on mdlvldual wheelstops.
40 On the pavmg and dramage plan specIfy that the 11/2 mch of asphalt be
done in two lifts
41 The mmlmum average IIghtmg WIthin the parkmg areas may be one foot
candle subject to the specIficatIOn m LDR Chapter 23, ArtIcle II.A.
BUILDING DIVISION
Comments
42 Add to the bUlldmg(s) that are depIcted on the drawing tItled site plan a
Page 5
Quantum Busmess Center- Lots 32-38
FIle No NWSP 00-003
DEP AR TMENTS
INCLUDE REJECT
labeled symbol that IdentIfies the locatIOn of the handIcap accessible
entrance door to the each tenant space Show and label the same door(s)
on the drawmg titled partial floor plan.
43 Add a labeled symbol to the drawmg that IS tItled site plan. The symbol
shall represent and delmeate the path of travel of the accessible route
that IS reqUIred between the accessible parkmg spaces and the
accessible entrance doors to each tenant space Identify on the plan the
Width ofthe accessible route (Note The mmlmum width reqUIred by
the code IS forty-four (44) mches) Add text that would mdlcate that the
symbol represents the accessible route and the route IS deSigned m
comphance wIth SectIOn 4.3 (Accessible Route) and 4 6 (Parkmg and
Passenger Loadmg Zones) of the Flonda Accessiblhty Code for
BUlldmg ConstructIOn The symbol Will represent the locatIOn of the
path of travel, not the location of the detectable wammg or other
pavement markmgs that are reqUIred to be mstalled along the path.
Please note that at time of permit review the applIcant shall proVide
detaIled documentatIOn on the plans that wIll venfy that the accessible
routes are m comphance With the regulatIOns speCified m the Flonda
Accessiblhty Code for BUlldmg Construction.
44 Wlthm the site statistics found on the cover sheet and sheet A-I,
Identify the proposed finish floor elevatIOn of the buildmg (lowest floor
elevatIOn) Venfy that the proposed elevatIOn complies With regulatIOns
of the code by addmg speCificatIOns and notes to the site data that
address the followmg Issues
a) From the FIRM map, Identify the title ofthe flood zone that the building is
located within. Where applicable, specify the base flood elevation. If
there is no base flood elevation, mdicate that on the plans.
b) As the deSign professional-of-record for the project, state that the
proposed floor elevation IS above the highest 100-year base flood
elevatIOn apphcable to the bUlldmg Site, as determmed by the South
Flonda Water Management Dlstnct s surface water management
constructIOn development regulatIOns. [SectIOn 3107 1.2, Chapter
31 of the Boynton Beach amendments to the 1997 edition of the
Standard BUlldmg Code]
c) Identify the floor elevatIOn that the deSign profeSSIOnal has
estabhshed for the bUlldmg wlthm the footprint of the bUlldmg that
IS shown on the site plan, floor plan and CIVil plan.
42 Add the followmg notes to the site plan that depicts the proposed
location of the site lIghtmg poles/fixtures.
a) State that the locatIOns of the site hghtmg poles are conceptual.
b) State that the site hghtmg Will be evaluated for code complIance at
time of permit review
c) State that the proposed site hghting fixtures wIll Illuminate the site
consistent With the speCifications IdentIfied m the Parkmg Lot
Code
d) Identify the overall height dimenSIOn of the site hghtmg pole and
Page 6
Quantum BusIness Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
fixture (Note The overall height ofthe pole/fixture shall not
exceed the heIght lImItatIons of the ZonIng Code)
Omit the pole lIghtIng photometnc InformatIOn and draWIng. This
Information is reqUired at tIme of permit submittal, not at site plan
review
43 On the draWIng tItled site plan, Identify the symbol that represents the
property lIne
44 The submitted site plan and survey depict two of the three bUildIngs
beIng constructed wIthIn an easement. Amend the plans so that
structures do not encroach Into an easement.
45 IndIcate In the site statIstIcs that each bUildIng IS one story IndIcate the
number of stones wIthIn the footpnnt of each bUildIng that IS depIcted
on the floor plan draWIngs
46 Below the draWIngs tItled Partial Floor Plan, add text that would
IndIcate that the draWIng IS conceptual.
47 At tIme of permIt submIttal, prOVIde a completed and executed CIty
umty of tItle form The form shall describe all lots, parcels or tracts
combIned as one lot. A copy of the deed With legal descnptlOns of each
property that IS beIng umfied IS reqUired to process the form The
property owner that IS IdentIfied on each deed shall match.
48 WIthIn the site statistics found on the cover sheet and WithIn the site
statistics found on sheet A-I, IdentIfy the uses proposed for each
bUildIng.
49 WithIn the site statistics found on the cover sheet, a F-2 occupancy
claSSIficatIOn was IdentIfied, however, the 1997 edItIon of the Standard
BUildIng Code IncludIng the City's amendments to the Standard
BUildIng Code do not IdentIfy an F-2 claSSIficatIOn. Amend the plans
accordIngly
P ARKS AND RECREA nON
Comments NONE
FORESTER/ENVIRONMENTALIST
Comments
49 The applicant must submIt an envIronmental assessment of the SIte Flora
and Fauna. ThIS should be completed as part of the SIte plan submIttal
process.
50 The eXistIng gopher tortOises must be relocated off the SIte pnor to the
Page 7
Quantum Busmess Center - Lots 32-38
FIle No NWSP 00-003
LJLJ~ ,..~~.TMENTS INCLUDE REJECT
sIte cleanng and grubbmg permIt Issuance
51 The topographIc survey of the sIte mdICates eXIstmg trees WhIch should
be Identified, and shown to be preserved m place, relocated or
removed/replaced on the SIte This should be completed on the
landscape plan.
PLANNING AND ZONING
Comments
52 For the second submIttal, put plans together m one package All plan
sheets should be 24"x 36" SIze
53 ProvIde SIte plan sheets at 1 "=30 scale to match landscape and
engmeenng plans
54 ProvIde traffic control markmgs and sIgnage for the vehIcular use areas
(stop SIgns, dIrectional SIgns etc). (Chapter 4 - SIte Plan RevIew)
55 ApplIcant has prOVIded a colored elevatIOn drawmg wIth color ChIpS.
PrOVIde a mounted colored elevatIOn drawmg for the Planmng and
Development Board meetmg. (Chapter 4 - SIte Plan RevIew)
56 The north and south elevatIOn drawmgs are mIslabeled. Please correct.
(Chapter 4, SIte Plan RevIew)
57 BUlldmgs I and 3 are located on eXIstmg utIlIty easements. EIther move
the bUIldmgs or relocate these utIlIty easements. (Chapter 4 - SIte Plan
RevIew)
58 IndIcate the location and dImenSIOn of landscape SIght tnangles on the
landscape plan sheets (Chapter 75 Article II, Landscape Code)
59 IndIcate the locatIOn of the fire hydrants and SIte lIghtmg on the
landscape plan. There appears to be conflIcts between landscapmg, SIte
IIghtmg and fire hydrant placement. (Chapter 7.5 ArtIcle II, Landscape
Code)
60 The dnveway openmg located west of Buildmg 2 has a dimenSIOn
greater than the maXImum permItted 32 feet. IndIcate the exact
dImenSIOn of thIS driveway on the SIte plan Approval is required for thIS
dnveway WIdth. (Chapter 23 - Parkmg Lots)
61 Label the dImenSIOn for the dnveway throat for the major dnveway
entrance on Quantum Blvd. (Chapter 23 - Parkmg Lots)
62 The dnve aIsle dIrectly east of BUIldmg 1 encroaches mto the 40 foot
landscape buffer cuttmg It off at the corner ReVIse the deSIgn of thIS
Page 8
Quantum Busmess Center - Lots 32-38
FIle No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
area to prevent the encroachment. (Chapter 23 - Parking Lots.)
63 IndIcate and label the nght-of-way lIne for Gateway Blvd. and Quantum
Blvd. on the sIte plan. (Chapter 23 - Parkmg Lots.)
64 ProvIde a contmuous concrete sIdewalk through the dnveway entrances
along Gateway Blvd. (NW 22nd Ave) (Chapter 23 - Parkmg Lots)
65 The sIte plan mdIcates that six (6) dnveways are proposed for thIS
project. No more than two (2) dnveways are permItted per street
frontage A vanance WIll be reqUIred to permit additIOnal driveways.
(Ch. 23, Art. II, H, 7)
66 PrOVIde a SIdewalk along Quantum Blvd. (Ch. 6, Art. III, 11)
67 ProVIde pedestrIan/handIcapped access from the main entrance of
BUlldmgs 2 and 3 to a SIdewalk along Quantum Blvd. (Ch. 9,Sec 10, B)
68 The back ofBUlldmg I faces Quantum Blvd. wIth a faIrly large
unobstructed vIewmg area of the bay doors and dumpster enclosures
from the street, partIcularly at the large major entrance dnve Some
bermmg IS prOVIded but does not appear to create a sufficIent buffer as
reqUIred by Ch. 9 - CommunIty DesIgn Standards or the Quantum
DesIgn RevIew GUIdelInes. RedeSIgn of thIS area IS reqUIred.
69 Approval of thIS project IS reqUIred from the Quantum Design ReVIew
CommIttee (QDR)
70 A total of three (3) free standmg SIgns are proposed for the SIte, one for
each of the three bUlldmgs. In addItIOn, typIcal wall SIgn desIgns were
submItted as a separate I I mches x 17 mches color drawmg labeled 2 0
The SIgns as presented are conSIstent WIth the approved Quantum
Master SIgn Program PrOVIde a scaled detaIl drawmg of the typIcal wall
SIgns on sheet A-2 of the site plan package The permItted square
footage for wall SIgns IS I 5 square feet for each one (I) foot of lInear
bUlldmg bay frontage
nSHRDA TA\PLANNINGiSHAREDlWP\PROJECTSiQUANTUM 2000\LOTS 32 38ilST REVIEW CO:"1J'.lENTS.DOC
-
Page 2
Quantum Business Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS
INCLUDE REJECT
8 LOR Chap 6, Article IV, Sec 16 reqUires that all pomts on each
bUlldmg will be wlthm 200 feet of an eXisting or proposed fire hydrant.
Please demonstrate that the plan meets this conditIOn, by showmg all
hydrants.
9 A bUlldmg permit for this project shall not be Issued until this office has
approved the plans for the water and/or sewer improvements required to
serve the proJect. (Sec 26-15)
10 The waste stream from all manufactunng process must meet the City'S
pretreatment requirements. A samplmg pomt must be provided to allow
mOOltonng of any waste stream (Sec 26-143,26-147)
FIRE
Comments
11 A fire flow test is required pnor to construction. LDR 6-16
12 Hydrants and access roads must be in place pnor to above grade
constructIOn. NFP A 1
POLICE
Comments.
13 At thiS time there are no roadway markings or traffic flow pattern
markings. I do foresee a couple of problem areas that will need to be
addressed before final approval.
ENGINEERING DIVISION
Comments
14
On the Site Plan add a general note that all plans submitted for specific
permits shall meet the City'S code reqUirements at time of application.
These permits mclude, but are not limited to the following: site IIghtmg,
pavmg, dramage, curbmg, landscapmg and lITIgatIOn. Permits required
from other permitting agencies, such as FOOT, PBC, SFWMD, DERM,
L WDD, OEP and any others, shall be included With the permit request.
(~
;----, ~
( UJ /1
ouT
15
Abandon that portIOn of the recorded 10 foot utility easement between
lots 32 & 33 to accommodate the new constructIOn.
16
Abandon that portion of the recorded 10 foot utility easement between
lot 38 and lots 36 & 37 to accommodate the new construction.
-
17
Provide a general note on sheet 4 of the paving and drainage plans that
the exfiltratlon system shall conform to City Standard Drawmg B-91007
() V--
II
29
-7
Page 3
Quantum BUSIness Center - Lots 32-38
File No NWSP 00-003
23
24
25
26
P ARTMENTS
INCLUDE REJECT
18 Any fill operatIon shall reqUIre an excavatIOn/fill permIt.
19
Show the draInage plan at the same scale as the site development plan.
[LDR Chapter 4, Section 7.F ]
OuT
20
On the site and CIvIl plans show the 5 foot concrete sIdewalk through
both drIveways along Gateway Blvd. with a mInImum thIckness of 6"
[LDR Chapter 23, Article II P ]
{JUT
21
On the sIte and CIvIl plans add a general note that all strIping, markIngs
and Slgnage shall conform to CIty Standard DraWIng B-91 007 and
reflect all striping, markIng and slgnage on both plans. [LDR Chapter 4,
SectIOn 7 B ]
our-:
22
Show proposed lIghtIng on both the landscape and CIvIl plans for
InspectIOn purposes and possible shadIng of parkIng lot areas. [LOR
Chapter 4, SectIOn 7.B ]
Q... \. \)\. L A~ \\~ \2 \l \..-
On the -Site 8R8 ItlRfJ.......,- plan indIcate the clear SIght tnan
two Gateway Boulevard drIveway.s
:m~rs~di.)"'~p-Pcifip1ti'n-Fne)'r-lAdix 5 L-D
~ -,
~~
OUT
On the SIte and landscape plans IndICate the clear SIght triangles along
the four Quantum Blvd. drIveways USIng the 35 foot legs of the triangle
as specified In LDR Chapter 7.5, ArtIcle II, SectIon 5.H.2
;<
\
()UT
On the landscape plans add a general note that the landscaping WIthin
the safe stght trIangles shall have a clear, unobstructed cross-visibIlIty
between 30 Inches and 6 feet above the pavement. [LOR Chapter 7.5,
Article II, SectIOn 5.H.]
eJue
On the sIte and CIvIl plans show a five foot concrete sidewalk along
Quantum Blvd. to the lImIts of the sIte or obtain a waiver therefrom
[LOR Chapter 22, ArtIcle I, SectIOn 5 & Chapter 6, ArtIcle IV, SectIOn
lOt.]
001=
27 Reduce the drIveways along Quantum Blvd. from four to two per code
or obtaIn a varIance therefrom [LOR Chapter 23, ArtIcle I, Section 3.B
& ArtIcle II.H.7 & LOR Chapter 2, Section 7.H.3 ]
28
-::;> tJW
-:: -
On the SIte and Civil plans show the 5 foot handIcap accessible paths
flush through the SIdewalks WIth a ramp up on either SIde per Flonda
AccessibIlIty Code (8 places)
uUT
~l-\Cl,.... p\l-L... Te.I-\F~ll(... C~~Tt:..uL .
~ iQ,N~"C ~N~ VV\A:2..""-....,I'GS' otC
The maxImum drIveway WIdth is 32 feet. ObtaIn an approval for the
south dnveway along Quantum Blvd. [LOR Chapter 23, ArtIcle II H.l ]
:::>l Lb
Page 4
Quantum BuslOess Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS
30
~
)
32
33
34
35
36
If a sidewalk IS reqUired along Quantum Blvd, then handicap assessible
paths should be shown through the landscaped areas gomg to the
Sidewalk per Flonda Accessibility Code It is recommended that there
be one for BUlldmg #2 and two for Buildmg #3 ~
~ \'-..J\:)"D=- l~(-\ \ l ~~ 5tLx;:Vi3V-i:-
O h ~I .~ ~W\IA.TCl~t.5:~~.,VGR.\M'5L~
t e Ivan r VI cros\"sec90 so e tal wlOe{rea~~o~m~
the evat na f nce etw~the 51 a th<(abuffin4Y
pr e les
a. Lot and
b ts3 3
c' Lots 30 A & J
Remove the reference to a "tow away zone" on the handicap post Sign.
See Standard Drawmg B-9800 1
On the pavlOg and dramage plan Identify the 4 sheets on the locatIOn
map for reference purposes.
Specify a 12 lOch mlOlmum subgrade thickness on the "typical
pavement on Sheet 4 of 4 of the civIl drawmgs.
Correct the elevatIOn callouts of Buildings # 1 & #'2.
Clarify use of existmg 48inch CM? at Building #3
37 Show UOlty of Title for all 8 lots.
RECOMMENDA nONS
38
39
40
41
Locate the handicap post Sign withlO the landscape areas behlOd the
Sidewalk.
In lieu of wheels tops and the asphalt between them and the 5 foot
Sidewalks along the buIldlOgs, construct 7 foot sidewalks lOcorporatlOg
the edge of curb as a continuous wheelstop ThiS reduces malOtenance
and the potential tnpplOg hazards on lOdlvidual wheelstops.
On the pavlOg and dralOage plan specify that the 11/2 lOch of asphalt be
done 10 two lifts. C -.A.Wiv -.) T 00(S..LI...... ~ '-" 5 - 3 ~s-. ~I=\LL - '<-
C=t\kS IfJ~ L
The mlOlmum average lightmg wlthm the parking areas may be one foot
candle subject to the speCification 10 LDR Chapter 23, Article II.A.
BUILDING DIVISION
Comments
42 Add to the buildmg(s) that are depicted on the drawmg titled site plan a
INCLUDE REJECT
OuT
t"/Y\.8'rV' \
CO ~A I>..:=:
^
, .
r-
uG' '-.;;:) ~
ovT
L: ~ --c.-
() \)\,
GU\__
UU(~
OvT~
GuT
C) \J T~
1 st REVIEW COMMENTS
e;
~
;5-
Project name QUANTUM BUSINESS CENTER (LOTS 32-38)
File number' NWSP 00-003
Reference 1st ReView, File # NWSP 00-001 wIth a January 1 L 2000 Plannmg and Zoning Department date
stamp markmg
DEPARTMENTS INCLUDE REJECT
PUBLIC WORKS
Co
~ILlTIES ",
\
.......
comments'
UJ All utilIties easements shall be shown on the rectified landscapmg
draw lOgs so that utilities may determme which trees may interfere with
utilities. In general, palm trees will be the only tree species allowed
wlthm utility easements. Canopy trees may be planted outsIde of the
easement so that roots and branches will not impact those utilities Within
the easement m the foreseeable future LDR Sec 7.5-18 1 gives public
utilities the authonty to remove any trees that mterfere WIth utility
services, either 10 utility easements or public nghts-or way
(j) Dept. of Health permits may be required for the water and sewer
systems servmg thIS project. (Sec. 26-12).
~ fire flow calculatIOns will be required demonstratmg the City Code
reqUIrement of 1500 g.p.m. as stated m LDR Chapter 6, Article IV,
Section 16, or the reqUIrement Imposed by msurance underwrIters,
whichever IS greater (see SectIOn 26-16(a)) Please submit these
calculatIOns With your Health Department permit submittal.
~ SectIOn 26-34(E) of the City Code reqUIres that a capacity reservation
fee be paId for thiS project eIther upon my request for sIgnature on the
Health Dept. applicatIOn forms or withm 30 days of site plan approval,
whIchever occurs first. ThiS fee will be determmed based upon final
meter Sizes, or expected demand.
((J Comp Plan policy 3C.3 4 reqUIres the conservation of potable water
City water may not, therefore, be used for lITigatIOn where other sources
are readily available
)J Water and sewer lines to be owned and operated by the City shall be
Included wlthm utility easements. The easements shall be dedicated via
separate mstruments to the City as stated In Sec. 26-33(a) of the Code
~ Utility Department will not reqUIre surety for mstallatlOn ofthe water
and sewer utilIties, on conditIOn that the systems be fully completed, and
given to the City before the first permanent meter IS set. Note that
settIng of a permanent water meter IS a prereqUIsite to obtaming the
certificate of occupancy
Page 2
Quantum BusIness Center - Lots 32-38
FIle No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
(i) LDR Chap 6, Article IV, Sec 16 requires that all pomts on each
buIldmg wIll be WithIn 200 feet of an eXlstmg or proposed fire hydrant.
Please demonstrate that the plan meets thiS conditiOn, by showing all
hydrants.
)1 A buildmg permit for thiS project shall not be Issued until thIS office has
approved the plans for the water and/or sewer Improvements reqUired to
serve the project. (Sec 26-15)
fj The waste stream from all manufactunng process must meet the City's
pretreatment reqUirements. A samplmg pomt must be provIded to allow
momtoring of any waste stream (Sec 26-143,26-147)
FIRE
Comments
II A fire flow test IS reqUired pnor to construction. LDR 6-16
12 Hydrants and access roads must be m place pnor to above grade
constructiOn. NFP A 1
POLICE
Comments
13 At thIS time there are no roadway markmgs or traffic flow pattern
markmgs. I do foresee a couple of problem areas that wIll need to be
addressed before final approval.
ENGINEERING DIVISION
Comments.
14 On the Site Plan add a general note that all plans submitted for specific
permIts shall meet the City'S code reqUirements at time of apphcatiOn.
These permits mclude, but are not hmlted to the followmg: site hghtmg,
paVIng, dramage, curb 109, landscapmg and IrngatIon. Permits reqUired
from other permlttmg agencies, such as FDOT, PBC, SFWMD, DERM,
L WDD, DEP and any others, shall be mcluded With the permit request.
15 Abandon that portion of the recorded 10 foot utIlity easement between
lots 32 & 33 to accommodate the new constructiOn.
16 Abandon that portiOn of the recorded 10 foot utlhty easement between
lot 38 and lots 36 & 37 to accommodate the new constructIon.
17 ProVide a general note on sheet 4 of the pavmg and dramage plans that
the exfiltratiOn system shall conform to City Standard Drawmg B-91 007
Page 3
Quantum Busmess Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
18 Any fill operatiOn shall reqUire an excavatIOn/fill permit.
19 Show the dramage plan at the same scale as the site development plan.
[LDR Chapter 4, SectiOn 7.F ]
20 On the site and civil plans show the 5 foot concrete sidewalk through
both driveways along Gateway Blvd. with a mInimum thickness of 6"
[LDR Chapter 23, Article 1I.P ]
21 On the Site and Civil plans add a general note that all striping, markings
and slgnage shall conform to CIty Standard DraWIng B-91 007 and
reflect all stripIng, markIng and slgnage on both plans. [LDR Chapter 4,
SectIon 7.B ]
22 Show proposed IIghtmg on both the landscape and CIVil plans for
mspectlOn purposes and possible shadIng of parking lot areas. [LDR
Chapter 4, SectiOn 7.B ]
23 On the Site and landscape plans mdIcate the clear sight triangle for the
two Gateway Boulevard driveways and at the Quantum Boulevard
IntersectiOn as specified In FDOT Index 546
24 On the site and landscape plans indicate the clear Sight tnangles along
the four Quantum Blvd. driveways using the 35 foot legs of the tnangle
as specIfied m LDR Chapter 7.5, ArtIcle II, SectiOn 5.H.2
25 On the landscape plans add a general note that the landscapIng WithIn
the safe Sight triangles shall have a clear, unobstructed croSS-VIsibility
between 30 mches and 6 feet above the pavement. [LDR Chapter 7.5,
ArtIcle II, Section S.H.]
26 On the site and CIVil plans show a five foot concrete Sidewalk along
Quantum Blvd. to the lImits of the site or obtain a waiver therefrom
[LDR Chapter 22, Article I, SectIon 5 & Chapter 6, Article IV, Section
lOt.]
27 Reduce the driveways along Quantum Blvd from four to two per code
or obtaIn a variance therefrom. [LDR Chapter 23, Article I, Section 3.B
& Article II.H.7 & LDR Chapter 2, SectiOn 7.H.3 ]
28 On the SIte and CIVil plans show the S foot handIcap accessible paths
flush through the Sidewalks With a ramp up on either Side per FlOrida
AccessibIlity Code (8 places)
29 The maximum driveway Width IS 32 feet. ObtaIn an approval for the
south driveway along Quantum Blvd. [LDR Chapter 23, ArtIcle 1I.H.l ]
Page 4
Quantum Busmess Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
30 If a sidewalk IS reqUIred along Quantum Blvd, then handicap assessible
paths should be shown through the landscaped areas gomg to the
sidewalk per Flonda Accessiblhty Code It IS recommended that there
be one for Butldmg #2 and two for Buildmg #3
31 On the cIvil plans provide cross-sectIOns of the followmg areas showmg
the elevatlOnal differences between the finished site and the abuttmg
properties
a. Lot 32 and the sand pme preserve to the north.
b Lots 32 & 33 along the water management Tract "J"
c Lots 34A & 34B along the unplatted parcel to the east
32 Remove the reference to a "tow away zone" on the handicap post sign.
See Standard Drawmg B-9800 1
33 On the pavmg and dramage plan identify the 4 sheets on the locatIOn
map for reference purposes.
34 Specify a 12 mch mmlmum sub grade thickness on the "typical
pavement on Sheet 4 of 4 of the CIVtl drawmgs.
35 Correct the elevation callouts of Buildmgs # 1 & #2.
36 Clanfy use of existmg 48mch CMP at Butldmg #3
37 Show Unity of Title for all 8 lots.
RECOMMENDA nONS
38 Locate the handicap post sign wlthm the landscape areas behmd the
Sidewalk.
39 In heu of wheelstops and the asphalt between them and the 5 foot
Sidewalks along the buildmgs, construct 7 foot Sidewalks incorporatmg
the edge of curb as a continuous wheelstop ThiS reduces mamtenance
and the potential tnppmg hazards on mdlvldual wheelstops
40 On the pavmg and dramage plan specify that the 1112 mch of asphalt be
done m two hfts.
41 The minimum average hghtmg wlthm the parking areas may be one foot
candle subject to the speCificatIOn m LDR Chapter 23, Article II.A.
BUILDING DIVISION
Comments.
42 Add to the bUlldmg(s) that are depicted on the drawmg titled site plan a
Page 5
Quantum Busmess Center - Lots 32-38
FIle No NWSP 00-003
I DEPARTMENTS I INCLUDE I REJECT I
labeled symbol that IdentIfies the locatIOn of the handicap accessible I
entrance door to the each tenant space. Show and label the same door(s)
on the drawmg titled partial floor plan
43 Add a labeled symbol to the drawmg that IS titled site plan. The symbol
shall represent and delmeate the path of travel of the accessible route
that IS reqUired between the accessible parkmg spaces and the
accessible entrance doors to each tenant space Identify on the plan the
width of the accessible route (Note The mlmmum width required by
the code IS forty-four (44) mches). Add text that would mdlcate that the
symbol represents the accessible route and the route IS designed m
compliance with SectIOn 4.3 (Accessible Route) and 4 6 (Parkmg and
Passenger Loadmg Zones) of the Flonda Accessibility Code for
BuIldmg ConstructIOn. The symbol wIll represent the locatIOn ofthe
path of travel, not the locatIOn of the detectable wammg or other
pavement markmgs that are required to be mstalled along the path.
Please note that at time of permit review the applicant shall prOVide
detailed documentatIOn on the plans that will verify that the accessible
routes are m compliance With the regulatIons speCified m the Florida
Accessibility Code for BUlldmg ConstructIOn.
44 Withm the site statistics found on the cover sheet and sheet A-I,
Identify the proposed fimsh floor elevation of the bUlldmg (lowest floor
elevatIOn) Venfy that the proposed elevatIon complies With regulatIOns
of the code by addmg speCificatIOns and notes to the site data that
address the followmg Issues
a) From the FIRM map, identify the title of the flood zone that the building is
located withm. Where applIcable, specify the base flood elevation. If
there is no base flood elevation, indicate that on the plans.
b) As the deSign professlOnal-of-record for the proJect, state that the
proposed floor elevatIOn is above the highest 100-year base flood
elevatIOn applicable to the bUlldmg SIte, as determmed by the South
Flonda Water Management Dlstnct's surface water management
construction development regulatIOns. [Section 3107 1.2, Chapter
31 of the Boynton Beach amendments to the 1997 edition of the
Standard BUlldmg Code]
c) Identify the floor elevatIOn that the deSign professIOnal has
established for the bUlldmg wlthm the footprmt of the bUlldmg that
IS shown on the site plan, floor plan and CIVil plan.
42 Add the following notes to the site plan that depicts the proposed
locatIOn of the site IIghtmg poles/fixtures.
a) State that the locatIOns of the site lIghtmg poles are conceptual.
b) State that the site IIghtmg wIll be evaluated for code compliance at
time of permit review
c) State that the proposed site lighting fixtures wIll I1lummate the site
consistent with the speCificatIOns IdentIfied m the Parkmg Lot
Code
d) Identify the overall height dimenSIOn of the site IIghtmg pole and
Page 6
Quantum Busmess Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
fixture (Note The overall heIght of the pole/fixture shall not
exceed the heIght lImItatIons of the Zonmg Code)
OmIt the pole IIghtmg photometnc mformatIOn and drawing. ThIs
mformation IS required at tIme of permIt submIttal, not at sIte plan
reVIew
43 On the drawmg tItled site plan, IdentIfy the symbol that represents the
property line
44 The submitted sIte plan and survey depIct two of the three bUIldings
bemg constructed within an easement. Amend the plans so that
structures do not encroach Into an easement.
45 IndIcate In the sIte statIstIcs that each bUIlding IS one story IndIcate the
number of stones Within the footpnnt of each bUIlding that IS depicted
on the floor plan draWings
46 Below the draWings tItled PartIal Floor Plan, add text that would
indicate that the draWing IS conceptual.
47 At tIme of permit submittal, prOVIde a completed and executed CIty
UOlty of title form. The form shall describe all lots, parcels or tracts
combined as one lot. A copy of the deed WIth legal descnptions of each
property that IS being uOlfied IS required to process the form. The
property owner that IS IdentIfied on each deed shall match.
48 Within the site statistics found on the cover sheet and WIthin the site
statistics found on sheet A-I, IdentIfy the uses proposed for each
budding.
49 Within the site statistics found on the cover sheet, a F-2 occupancy
classificatIOn was IdentIfied, however, the 1997 editIon of the Standard
BUIlding Code including the City's amendments to the Standard
BUIlding Code do not IdentIfy an F-2 classIficatIOn. Amend the plans
accordingly
P ARKS AND RECREATION
Comments NONE
FORESTER/ENVIRONMENT ALIST
Comments
49 The applIcant must submit an envIronmental assessment ofthe site Flora
and Fauna. ThiS should be completed as part of the site plan submittal
process
50 The eXisting gopher tortoises must be relocated off the SIte pnor to the
Page 7
Quantum Busmess Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
sIte cleanng and grubbmg permIt Issuance
51 The topographIc survey of the sIte mdlcates eXlstmg trees whIch should
be identIfied, and shown to be preserved m place, relocated or
removed/replaced on the sIte ThIS should be completed on the
landscape plan.
PLANNING AND ZONING
Comments
52 For the second submIttal, put plans together m one package All plan
sheets should be 24"x 36" sIze
53 PrOVIde sIte plan sheets at 1 "=30 scale to match landscape and
engmeermg plans.
54 Provide traffic control markmgs and slgnage for the vehIcular use areas
(stop sIgns, dIrectIonal sIgns etc). (Chapter 4 - SIte Plan RevIew)
55 Apphcant has prOVIded a colored elevatIOn drawing WIth color ChIpS.
PrOVIde a mounted colored elevatIon drawmg for the Plannmg and
Development Board meetmg. (Chapter 4 - SIte Plan RevIew)
56 The north and south elevatIon drawmgs are mIslabeled. Please correct.
(Chapter 4, SIte Plan RevIew)
57 BUlldmgs 1 and 3 are located on eXlstmg utlhty easements. EIther move
the bUlldmgs or relocate these utIhty easements. (Chapter 4 - SIte Plan
RevIew)
58 IndIcate the locatIOn and dImenSIOn of landscape SIght tnangles on the
landscape plan sheets. (Chapter 75, ArtIcle II, Landscape Code)
59 IndIcate the locatIOn of the fire hydrants and site hghtmg on the
landscape plan. There appears to be conflIcts between landscapmg, sIte
hghtmg and fire hydrant placement. (Chapter 7.5, ArtIcle II, Landscape
Code)
60 The dnveway openmg located west of BUIlding 2 has a dImenSIOn
greater than the maXImum permItted 32 feet. IndIcate the exact
dImenSIOn of this dnveway on the sIte plan. Approval IS reqUIred for thIS
dnveway WIdth. (Chapter 23 - Parkmg Lots)
61 Label the dImenSIOn for the dnveway throat for the major driveway
entrance on Quantum Blvd. (Chapter 23 - Parkmg Lots)
62 The dnve aIsle dIrectly east of Buddmg I encroaches mto the 40 foot
landscape buffer cuttmg It off at the comer ReVIse the deSIgn of thIS
Page 8
Quantum Busmess Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
area to prevent the encroachment. (Chapter 23 - Parkmg Lots.)
63 Indicate and label the nght-of-way lme for Gateway Blvd. and Quantum
Blvd on the site plan. (Chapter 23 - Parkmg Lots.)
64 Provide a contmuous concrete sidewalk through the dnveway entrances
along Gateway Blvd. (NW 22nd Ave) (Chapter 23 - Park 109 Lots.)
65 The site plan mdlcates that SIX (6) dnveways are proposed for thiS
project. No more than two (2) driveways are permitted per street
frontage A vanance will be reqUired to permit additional driveways.
(Ch. 23, Art. II, H, 7)
66 ProVide a Sidewalk along Quantum Blvd. (Ch. 6, Art. III, 11)
67 ProVide pedestnan/handlcapped access from the maIO entrance of
BUlldmgs 2 and 3 to a Sidewalk along Quantum Blvd. (Ch. 9,Sec 10, B)
68 The back of BUlldmg 1 faces Quantum Blvd. with a fairly large
unobstructed vlewmg area of the bay doors and dumpster enclosures
from the street, particularly at the large major entrance dnve Some
bermmg IS proVided but does not appear to create a suffiCient buffer as
reqUired by Ch. 9 - Commumty DeSign Standards or the Quantum
DeSign ReView GUidelInes. RedeSign of thiS area IS required.
69 Approval of thiS project is required from the Quantum Design Review
Committee (QDR)
70 A total of three (3) free stand 109 signs are proposed for the Site, one for
each of the three bUlldmgs. In additIOn, typical wall sign designs were
submitted as a separate 11 mches X 17 mches color drawmg labeled 2.0
The signs as presented are consistent With the approved Quantum
Master Sign Program. ProVide a scaled detail drawmg of the typical wall
signs on sheet A-2 of the site plan package The permitted square
footage for wall signs IS 1 5 square feet for each one (1) foot of lmear
bUlldmg bay frontage.
J\SHRDA T A\PLANNING\SHAREDlWP\PROJECTS\QUANTUM 2000\LOTS 32 38\ I ST REVIEW COMMEl'iTS DOC
1 st REVIEW COMMENTS
Project name QUANTUM BUSINESS CENTER (LOTS 32-38)
File number NWSP 00-003
Reference 1st ReView, File # NWSP 00-001 with a Januarv 11, 2000 Planning and Zoning Department date
stamp markmg
DEPARTMENTS INCLUDE REJECT
PUBLIC WORKS
Comments.
UTILITIES
Comments
1 All utihties easements shall be shown on the rectified landscapmg
drawmgs so that utihties may determine which trees may mterfere with
utihtles. In general, palm trees will be the only tree specIes allowed
withm utihty easements. Canopy trees may be planted outsIde of the
easement so that roots and branches will not Impact those utIhtles wlthm
the easement m the foreseeable future. LDR Sec. 7.5-18 1 gIves public
utilItIes the authorIty to remove any trees that mterfere wIth utihty
servIces, eIther m utlhty easements or pubhc nghts-or way
2 Dept. of Health permits may be requIred for the water and sewer
systems servmg thiS project. (Sec 26-12).
3 Fire flow calculatIOns WIll be reqUired demonstratmg the City Code
reqUirement of 1500 g.p.m. as stated m LDR Chapter 6, Article IV,
Section 16, or the reqUirement imposed by msurance underwriters,
whichever IS greater (see Section 26-16(a)) Please submIt these
calculatIOns WIth your Health Department permit submittal.
4 SectIOn 26-34(E) of the City Code reqUires that a capacity reservatIOn
fee be paid for thIS project either upon my request for signature on the
Health Dept. applicatIOn forms or within 30 days of site plan approval,
whichever occurs first. ThiS fee will be determmed based upon final
meter Sizes, or expected demand.
5 Comp Plan pohcy 3C.3 4 requires the conservatIOn of potable water
City water may not, therefore, be used for IrrIgatIOn where other sources
are readily available
6 Water and sewer hnes to be owned and operated by the City shall be
included wlthm utilIty easements. The easements shall be dedicated via
separate instruments to the City as stated m Sec 26-33(a) of the Code
7 UtIhty Department WIll not reqUire surety for mstallatIOn of the water
and sewer utilities, on condition that the systems be fully completed, and
given to the City before the first permanent meter IS set. Note that
settmg of a permanent water meter IS a prereqUisite to obtammg the
certificate of occupancy
Page 2
Quantum Business Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
8 LDR Chap 6, Article IV, Sec 16 reqUIres that all pOInts on each
bUIldIng wIll be wIthIn 200 feet of an eXIstIng or proposed fire hydrant.
Please demonstrate that the plan meets thiS condItIOn, by showing all
hydrants.
9 A buildmg permIt for thIS project shall not be Issued until thIS office has
approved the plans for the water and/or sewer Improvements required to
serve the project. (Sec 26-15)
10 The waste stream from all manufactunng process must meet the CIty'S
pretreatment requIrements. A samplIng pOInt must be provIded to allow
mOnItormg of any waste stream. (Sec 26-143,26-147)
FIRE
Comments
11 A fire flow test is reqUIred pnor to constructIOn. LDR 6-16
12 Hydrants and access roads must be In place pnor to above grade
construction. NFP A 1
POLICE
Comments
13 At thIS time there are no roadway markIngs or traffic flow pattern
markIngs. I do foresee a couple of problem areas that WIll need to be
addressed before final approval.
ENGINEERING DIVISION
Comments.
14 On the SIte Plan add a general note that all plans submItted for speCIfic
permIts shall meet the CIty'S code reqUIrements at time of applIcatIon.
These permIts Include, but are not lImIted to the follOWIng: site lighting,
pavmg, dramage, curbmg, landscapIng and lITIgatIOn. PermIts reqUIred
from other permIttIng agenCIes, such as FOOT, PBC, SFWMD, DERM,
L WDD, DEP and any others, shall be Included WIth the permIt request.
15 Abandon that portion of the recorded 10 foot utilIty easement between
lots 32 & 33 to accommodate the new construction.
16 Abandon that portIOn of the recorded 10 foot utIlIty easement between
lot 38 and lots 36 & 37 to accommodate the new constructIOn.
17 ProVIde a general note on sheet 4 of the pavmg and draInage plans that
the exfiltratlOn system shall conform to City Standard DraWIng B-91007
Page 3
Quantum Busmess Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
18 Any fill operation shall require an excavatIon/fill permit.
19 Show the dramage plan at the same scale as the site development plan.
[LDR Chapter 4, SectIOn 7 F ]
20 On the site and cIVIl plans show the 5 foot concrete sidewalk through
both dnveways along Gateway Blvd. with a mmlmum thickness of 6"
[LDR Chapter 23, Article II.P ]
21 On the site and civil plans add a general note that all stnpmg, markmgs
and slgnage shall conform to City Standard Drawing B-91007 and
reflect all stripmg, markmg and signage on both plans. [LDR Chapter 4,
SectIOn 7.B J
22 Show proposed IIghtmg on both the landscape and civil plans for
mspectIon purposes and possible shadmg of parking lot areas. [LDR
Chapter 4, Section 7.B ]
23 On the site and landscape plans mdlcate the clear sight tnangle for the
two Gateway Boulevard dnveways and at the Quantum Boulevard
mtersectlOn as specified m FDOT Index 546
24 On the site and landscape plans mdicate the clear sight tnangles along
the four Quantum Blvd. dnveways usmg the 35 foot legs of the trIangle
as specified m LDR Chapter 7.5, Article II, SectIOn 5.H.2
25 On the landscape plans add a general note that the landscapmg wlthm
the safe sight tnangles shall have a clear, unobstructed cross-visibilIty
between 30 mches and 6 feet above the pavement. [LDR Chapter 7.5,
Article II, SectIOn 5.H.]
26 On the site and cIvil plans show a five foot concrete Sidewalk along
Quantum Blvd. to the lImits of the site or obtam a Waiver therefrom.
[LDR Chapter 22, Article I, SectIOn 5 & Chapter 6, Article IV, SectIOn
10 t.]
27 Reduce the drIveways along Quantum Blvd. from four to two per code
or obtam a vanance therefrom. [LDR Chapter 23, Article I, SectIOn 3.B
& Article II.H.7 & LDR Chapter 2, SectIOn 7.H.3 ]
28 On the site and ciVil plans show the 5 foot handicap accessible paths
flush through the Sidewalks with a ramp up on either Side per FlOrIda
AccessibilIty Code (8 places)
29 The maximum dnveway Width IS 32 feet. Obtam an approval for the
south dnveway along Quantum Blvd. [LDR Chapter 23, Article I1.H.l ]
Page 4
Quantum BusIness Center - Lots 32-38
File No NWSP 00-003
I DEPARTMENTS I INCLUDE I REJECT I
30 If a sidewalk IS reqUIred along Quantum Blvd, then handicap assesslble
paths should be shown through the landscaped areas gOIng to the
SIdewalk per florIda Accessiblhty Code. It IS recommended that there
be one for BUIldIng #2 and two for BUIldIng #3
31 On the CIVtl plans proVide cross-sectIOns of the follOWIng areas shOWIng
the elevatlOnal differences between the fimshed site and the abuttIng
properties
a. Lot 32 and the sand pIne preserve to the north.
b Lots 32 & 33 along the water management Tract "J"
c Lots 34A & 34B along the unplatted parcel to the east
32 Remove the reference to a "tow away zone" on the handicap post sign.
See Standard Drawmg B-9800 1
33 On the pavmg and dramage plan Identify the 4 sheets on the locatIOn
map for reference purposes.
34 Specify a 12 Inch mmlmum subgrade thickness on the "typical
pavement on Sheet 4 of 4 of the CIVIl drawmgs
35 Correct the elevatIon call outs of BUlldmgs # 1 & #2.
36 Clanfy use of eXIstmg 48mch CMP at BUlldmg #3
37 Show Umty of Title for all 8 lots
RECOMMENDA nONS
38 Locate the handicap post sign wlthm the landscape areas behInd the
Sidewalk.
39 In heu of wheels tops and the asphalt between them and the 5 foot
SIdewalks along the bUlldmgs, construct 7 foot SIdewalks mcorporating
the edge of curb as a continuous wheelstop ThIS reduces maintenance
and the potentIal trIppmg hazards on indIVIdual wheelstops.
40 On the pavIng and dramage plan speCIfy that the 1112 Inch of asphalt be
done in two hfts
41 The mmImum average hghtmg WIthIn the parkmg areas may be one foot
candle subject to the speCificatIOn In LDR Chapter 23, ArtIcle II.A.
BUILDING DIVISION
Comments
42 Add to the butldmg(s) that are depIcted on the drawmg tItled site plan a
Page 5
Quantum BusIness Center - Lots 32-38
FIle No NWSP 00-003
DEPARTMENTS
INCLUDE REJECT
labeled symbol that IdentIfies the locatIOn of the handIcap accessible
entrance door to the each tenant space Show and label the same door(s)
on the drawIng tItled partial floor plan.
43 Add a labeled symbol to the drawIng that IS tItled site plan. The symbol
shall represent and delIneate the path of travel of the accessible route
that IS reqUIred between the accessible parkIng spaces and the
accessible entrance doors to each tenant space. Identlfy on the plan the
WIdth of the accessible route (Note The mInImum WIdth reqUIred by
the code is forty-four (44) Inches) Add text that would indIcate that the
symbol represents the accessible route and the route IS deSIgned in
complIance WIth SectIOn 4.3 (Accessible Route) and 4 6 (ParkIng and
Passenger LoadIng Zones) of the FlOrIda AccessibilIt} Code for
BUIldIng ConstructIOn The symbol WIll represent the locatIon of the
path of travel, not the locatIOn of the detectable warnIng or other
pavement markIngs that are reqUIred to be Installed along the path.
Please note that at tIme of permIt revIew the applIcant shall provide
detailed documentatIOn on the plans that WIll verIfy that the accessible
routes are In complIance WIth the regulatIons speCIfied In the flOrIda
AccessibIlIty Code for BuddIng ConstructIOn.
44 WithIn the site statistics found on the cover sheet and sheet A-I,
IdentIfy the proposed fimsh floor elevatIOn of the buddIng (lowest floor
elevatlon) VerIfy that the proposed elevatIon complies WIth regulations
of the code by addIng speCIficatIOns and notes to the site data that
address the follOWIng Issues
a) From the FIRM map, identify the title of the flood zone that the building is
located within. Where applicable, specify the base flood elevation. If
there is no base flood elevation, indicate that on the plans.
b) As the deSIgn professlOnal-of-record for the project, state that the
proposed floor elevatIOn IS above the hIghest 100-year base flood
elevation apphcable to the bUIldIng SIte, as determIned by the South
Flonda Water Management Dlstnct's surface water management
constructIOn development regulatIOns. [SectIOn 3107 1.2, Chapter
31 of the Boynton Beach amendments to the 1997 edItion of the
Standard BUIldIng Code]
c) IdentIfy the floor elevatIOn that the deSIgn profeSSIOnal has
establIshed for the bUIldIng WIthIn the footprInt of the bUIldIng that
is shown on the sIte plan, floor plan and CIvIl plan.
42 Add the follOWIng notes to the SIte plan that depIcts the proposed
location of the SIte lIghtIng poles/fixtures
a) State that the locatIOns of the sIte lIghtIng poles are conceptual.
b) State that the site lighting WIll be evaluated for code comphance at
time of permIt revIew
c) State that the proposed sIte lIghtIng fixtures WIll IllumInate the site
consIstent WIth the speCIficatIOns IdentIfied In the ParkIng Lot
Code
d) IdentIfy the overall height dimension of the site lIghtIng pole and
pag~---::="') ~
Quan m BusIness Center - L~
FIle NWSP 00-003
DEPARTMENTS INCLUDE REJECT
fixture (Note The overall height of the pole/fixture shall not
exceed the height limitations of the ZonIng Code)
Omit the pole lightIng photometnc InformatIOn and draWIng. This
informatIOn IS reqUired at time of permit submittal, not at site plan
review
43 On the draWIng titled site plan, identify the symbol that represents the
property line
44 The submitted site plan and survey depict two of the three bUildIngs
beIng constructed WithIn an easement. Amend the plans so that
structures do not encroach Into an easement.
45 Indicate In the site statistics that each bUildIng IS one story Indicate the
number of stones WithIn the footprInt of each bUilding that IS depicted
on the floor plan draWIngs
46 Below the draWIngs titled Partial Floor Plan, add text that would
Indicate that the draWIng IS conceptual.
47 At time of permit submittal, provide a completed and executed CIty
umty of title form The form shall describe all lots, parcels or tracts
combIned as one lot. A copy of the deed With legal descnptlOns of each
property that IS beIng umfied IS reqUired to process the form The
property owner that IS Identified on each deed shall match.
48 WithIn the site statistics found on the cover sheet and Within the site
statistics found on sheet A-I, Identify the uses proposed for each
bUildIng.
49 WithIn the site statistics found on the cover sheet, a F-2 occupancy
claSSificatIOn was Identified, however, the 1997 edItion of the Standard
BUildIng Code IncludIng the City'S amendments to the Standard
BuildIng Code do not identify an F-2 classificatIOn. Amend the plans
accordIngly
PARKS AND RECREATION
Comments NONE
[.....------------ ~~
( FORESTER/ENVIRONMENTALIST
~: ------
-----"
49 The applicant must submit an environmental assessment of the site Flora ~
and Fauna. ThiS should be completed as part of the site plan submittal
process
50 The eXistIng gopher tortoises must be relocated off the site pnor to the ~ ,,J,];j
fl E:-
Page 7
Quantum Bus10ess Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
site cleanng and grubb10g permit Issuance
51 The topographic survey of the site 10dlcates exist10g trees which should ft}
be Identified, and shown to be preserved 10 place, relocated or
removed/replaced on the site This should be completed on the
landscape plan.
PLANNING AND ZONING
Comments
~ For the second submittal, put plans together 10 one package All plan
sheets should be 24"x 36" size
r~ Provide site plan sheets at 1 "=30' scale to match landscape and
eng10eenng plans.
8 Provide traffic control mark10gs and signage for the vehicular use areas
(stop signs, directIOnal signs etc). (Chapter 4 - Site Plan Review) on~ 1t.(~Cl0-
55 Applicant has provided a colored elevatIOn draw10g with color chips.
Provide a mounted colored elevatIOn draw10g for the Planning and
Development Board meeting. (Chapter 4 - Site Plan Review)
56 The north and south elevatIOn drawmgs are mislabeled. Please correct.
(Chapter 4, Site Plan Review)
57 BUIldings 1 and 3 are located on eXIst10g utIlity easements. EIther move
the bUlldmgs or relocate these utility easements. (Chapter 4 - Site Plan
Review)
58 IndIcate the locatIOn and dimenSIOn of landscape sight tnangles on the
landscape plan sheets (Chapter 7.5, Article II, Landscape Code)
59 Indicate the locatIOn of the fire hydrants and SIte IIght10g on the
landscape plan. There appears to be conflIcts between landscap1Og, site
IIght10g and fire hydrant placement. (Chapter 7.5, Article II, Landscape
Code)
60 The dnveway open1Og located west of BUlld10g 2 has a dimenSIOn
greater than the maXImum permItted 32 feet. Indicate the exact
dimenSIOn of this dnveway on the site plan. Approval IS reqUIred for this
dnveway Width. (Chapter 23 - Park10g Lots)
61 Label the dimenSIOn for the dnveway throat for the major dnveway
entrance on Quantum Blvd. (Chapter 23 - Park10g Lots)
62 The dnve aisle directly east ofBUlldmg I encroaches mto the 40 foot
landscape buffer cuttmg It off at the comer Revise the deSign of thiS
Page 8
Quantum Busmess Center - Lots 32-38
Flle No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
area to prevent the encroachment. (Chapter 23 - Parkmg Lots)
63 Indicate and label the right-of-way Ime for Gateway Blvd. and Quantum
Blvd. on the site plan. (Chapter 23 - Parkmg Lots.)
64 Provide a continuous concrete sidewalk through the driveway entrances
along Gateway Blvd. (NW 22nd Ave) (Chapter 23 - Parkmg Lots.)
65 The site plan mdlcates that SIX (6) driveways are proposed for this
proJect. No more than two (2) driveways are permitted per street
frontage A variance Will be reqUired to permit additIOnal driveways.
(Ch. 23, Art. II, H, 7)
66 Provide a Sidewalk along Quantum Blvd. (Ch. 6, Art. III, 11)
67 Provide pedestrian/handicapped access from the mam entrance of
BUlldmgs 2 and 3 to a Sidewalk along Quantum Blvd. (Ch. 9,Sec 10, B)
~I The back ofBUlldmg 1 faces Quantum Blvd. With a fairly large
unobstructed vlewmg area of the bay doors and dumpster enclosures
from the street, particularly at the large major entrance drive. Some
bermmg is provided but does not appear to create a sufficient buffer as
reqUired by Ch. 9 - Commumty DeSign Standards or the Quantum
DeSign ReView GUidelines. Redesign of thiS area is reqUired. OI,G
69 Approval of thiS project IS required from the Quantum DeSign ReView
,---- Committee (QDR).
70 A total of three (3) free standmg signs are proposed for the Site, one for
each of the three bUlldmgs. In addition, typical wall sign deSigns were
submitted as a separate 11 mches X 17 mches color drawmg labeled 2 0
The signs as presented are consistent With the approved Quantum
Master Sign Program Provide a scaled detail drawmg of the typical wall
signs on sheet A-2 of the site plan package The permitted square
footage for wall signs IS 1 5 square feet for each one (1) foot of linear
bUilding bay frontage
J ISHRDA T A\PLANNlNGISHAREDlWP\PROJECTSIQUA:-rrUM 2000ILOTS 32 381 I ST REVIEW COMMENTS.DOC
Page 7
Quantum Business Center - Lots 32-38
File No NWSP 00-003
[IDOOill~u
DEPARTMENTS INCLUDE REJECT
The following comments relate to the reqUirements of Chapter 23 -Parkmg
Lots
- The driveway openmg located west of Buildmg 2 has a dimension greater
than the maximum permitted 32 feet. Indicate the exact dimenSIOn of this
driveway on the site plan. Approval IS reqUired for thiS driveway Width.
- Label the dimenSIOn for the driveway throat for the maJor driveway entrance
on Quantum Blvd.
- The drive aisle directly east of Building 1 encroaches mto the 40 foot
landscape buffer cuttmg it off at the corner ReVise the deSign of this area to
prevent the encroachment.
- Indicate and label the right-of-way Ime for Gateway Blvd. and Quantum
Blvd. on the site plan.
- Provide a contmuous concrete Sidewalk through the driveway entrances
along Gateway Blvd. (NW 22nd Ave)
- The site plan indicates that six (6) driveways are proposed for this project.
No more than two (2) driveways are permitted per street frontage. A
variance will be reqUired to permit additIOnal driveways. (Art. II, H, 7)
Provide a Sidewalk along Quantum Blvd. (Ch. 6, Art. III, 11)
ProVide pedestrian/handicapped access from the mam entrance of BUlldmgs 2
and 3 to a sidewalk along Quantum Blvd. (Ch. 9,Sec 10, B).
The back of BUlldmg 1 faces Quantum Blvd. With a fauly large unobstructed
viewmg area of the bay doors and dumpster enclosures from the street,
particularly at the large maJor entrance drive Some bermmg IS provided
but does not appear to create a suffiCient buffer as required by Ch. 9 -
Commumty DeSign Standards or the Quantum DeSign ReView
Guidelines. RedeSign of this area is reqUired.
Approval of this proJect is reqUired from the Quantum DeSign ReView
Committee (QDR)
A total of three (3) free standmg signs are proposed for the site, one for each of
the three buildings. In addition, typical wall sign deSigns were
submitted as a separate 11" x 17" color drawmg labeled 2 0 The signs
as presented are consistent With the approved Quantum Master Sign
Program. ProVide a scaled detail drawmg of the typical wall signs on
sheet A-2 of the site plan package The permitted square footage for
wall signs IS 1.5 square feet for each one (1) foot on lmear bUlldmg bay
frontage
J:ISHRDA T A\PLANNINGISHARED\\\'P\PROJECTSIQUANTUM 2000ILOTS 32 3811 ST REVIEW COMMENTS.DOC
/ //4 -
J::zk. ~ J'll(-it Ie I- y-y{; ; c Ic (c ~y,
/--I; f' P-< )LL.j...-, /'~J - ----h.. ~
(~ ,'J /t.. '. . '-....J.:.,;..:. L' t!o--< .
ri ('-- , ,fe-v 7
v.../ f -(<C<J ~0"" l -\ J/1jRtf..e }.o ~"- i. ~4 ;. )/. /k<
.re-I.:; ~ ~,c- , .A.. ~_yr I to" i -'::" I ~~ v ,//1 /JC~ I (,.l / .--4'-?/--
I E rf' i A 1 l'J'-F1f- .J,( 4 ,; / . ;'C'?). ,)o'/' 1~ :, / /
\lQ f'~ c" l' Y y '- ~/1 ,......{. ~ \ ~~ 'l~:... /l ((.'1...Y
Oi-:'2 GO ,Vtz-( ~:Q.",.~~~ l:~~> ~~~+\<:'(.\-:k t.-.;.,J ~i'-~__~~_,_____
)'/ r/ ,.1/,
UC, J
J'~'."" / -r . J-r. ,,) l/( ,1 rJ"'--'< uf-:,
~...,-" 1'---Z-....
--J/;J! t:') ?~J?,b ~
/j fl. ..L- '- t, . ,:;
}- 1'/. . -.,j'....? /!.-".'.f"'h.. ~/- r-~
v.............../))
LYL "rJUlyf {v' tC I/O /"c"'-<- --L.
J'e c:. ~ J---"'.Y-L<1.1o. I vv,J,I 'v ('-;f-
I
/ ) / D5 ;- - ('~ U~~.i" I. (/1'1/1./)
/
J II-''--'€~
I-,(~ c.4-<- /1
Y-1t /..,fj ~rf l'r tA../
(,.L,r
, /7T
2nd Review Comments
PrOject name QUANTUM BUSINESS CENTER (LOTS 32-38)
FIle number NWSP 00-001
Reference' 2nd Review. File # NWSP 00-001 With a February 22,2000 Plannmg and Zoning Department date
stamp marking.
DEPARTMENTS INCLUDE REJECT
PUBLIC WORKS
Comments
1 It IS the opmlOn of the PublIc Works Department that the dumpster enclosure
locatIOns need to be turned 10 to 20 degrees toward the traffic flow for
maximum service It IS also our opmlOn that centralIy located compactors,
by reducmg the number of receptacles, would better service thiS project and
be more cost effective m the long run.
UTILITIES
Comments.
2 All utility easements shall be shown on the rectified landscapmg drawmgs so
that the Utility Department may determme which trees may mterfere with
utilities. In general, palm trees wIll be the only tree species allowed wlthm
utilIty easements. Canopy trees may be planted outside of the easement so
that roots and branches will not Impact those utIlities Within the easement m
the foreseeable future LDR Sec. 7.5-18 1 gives public utilities the authOrity
to remove any trees that mterfere With utilIty services, either m utilIty
easements or public rights-of-way
3 Dept. of Health permits may be reqUIred for the water and sewer systems
servmg this proJect. (Sec. 26-12)
4 Fire flow calculatIOns wIll be reqUIred demonstratmg the City Code
reqUIrement of 1500 g.p.m. as stated m LDR Chapter 6, ArtICle IV, SectIOn
16, or the reqUIrement Imposed by insurance underwriters, whichever IS
greater (see SectIOn 26-16(a)). Please submit these calculatIOns with your
Health Department permit submittal.
5 LDR Chap 6 Article IV, Sec 16 reqUIres that all pomts on each bUlldmg
wllI be wlthm 200 feet of an eXlstmg or proposed fire hydrant. Please
demonstrate that the plan meets this condition by showing all hydrants and
necessary dimenSIOns.
6 The waste stream from all manufactUring processes must meet the City'S
pretreatment reqUIrements. A sampling pomt must be provided to allow
mOnItOring of any waste stream (Sec 26-143,26-147)
FIRE
Page 2
Quantum Busmess Center - Lots 32-38
File No NWSP 00-001
DEPARTMENTS INCLUDE REJECT
Comments
7 Show F.D ConnectIOns.
8 Hydrants and access roads must be in place prior to above grade constructIOn.
NFP A 1
POLICE
Comments.
9 See traffic control markmgs comment.
ENGINEERING DEPARTMENT
Comments.
10 Abandon that portion of the recorded 10- foot utility easement between lots
32 & 33 to accommodate the new constructIOn.
11 Abandon that portIOn of the recorded 10- foot utility easement between lot 38
and lots 36 & 37 to accommodate the new construction.
12 Anv fill operatIOn shall require an excavation/fill permit.
13 On the civll plans at the time of permitting, mdlcate the clear Sight triangles
for the two Gateway Boulevard driveways.
14 The maximum driveway Width is 32 feet. Obtam an approval from the
Department Director for the south driveway along Quantum Blvd, and
provide proper dimenSIOn measured at property Ime [LDR Chapter 23,
Article II.H.l 1
15 Show all traffic control slgna!!e and markings on the site plan.
16 Provide a note on the ciVil plans that the site development will match eXlstmg
perimeter grades.
17 Show Unity of Title for all 8 lots.
BUILDING DIVISION
Page 3
Quantum BusIness Center - Lots 32-38
File No NWSP 00-001
DEPARTMENTS INCLUDE REJECT
Comments
18 The submitted site plan and survey depict two of the three bUildings beIng
constructed withIn an easement. Before permit review, submit a copy of the
recorded CIty resolution that verifies the easements have been abandoned or
relocate bUildIngs to aVOId easements.
19 At tIme of permit submittal, provide a completed and executed City UnIty of
title form. The form shall describe all lots, parcels or tracts combIned as one
lot. A copy of the recorded deed for each property that IS beIng UnIfied IS
reqUired to process the form Each recorded deed shall Include a legal
deSCription and the owner Identified on each deed shall match.
20 At time of permit review provide detaIled draWIngs and documentatIOn on
the plans that wIll verify the accessible route from the accessible parking
spaces to the accessible building entrance IS In compliance with the
regulations of the FlOrida Accessibility Code for BUilding ConstructIOn. The
documentatIOn shall Include, but not be limited to, IdentifyIng the type of
material, surface finIsh, Width, cross slope, slope and length of the entire
accessible route includmg, where applIcable, landmgs, ramps and handrails.
21 Compliance with the BUildIng codes wIll be evaluated at time of permIt
review The Permit fee, water and sewer facIlity fees, Fire and Life Safety
fees, County fees and State fees Will be determIned at time of permit review
22. Permits are reqUired to construct the Improvements that are shown on the
approved site plan. Permit applicatIOn forms are available In the BUildIng
DIVision of the Development Department. A permit submittal checklist IS
available In the BuildIng DIVISIOn. The list Identifies the baSIC documents
that the Plans Analyst checks for when an applicant submits for plan review
PARKS AND RECREATION
Comments NONE
FORESTER/ENVIRONMENTALIST
Comments
23 The topographiC survey of the site Indicates eXistIng trees which should be
Identified, and shown to be preserved In place, relocated or removed/replaced
on the site This should be completed on the landscape plan.
PLANNING AND ZONING
Comments.
Page 4
Quantum Busmess Center - Lots 32-38
FIle No NWSP 00-001
DEP ARTMENTS INCLUDE REJECT
24 Provide traffic control and flow markIng and slgnage for the vehicular use
areas on the site plans (Stop signs, dlIectlOnal flow and signs etc ) (Chapter
4 - Site Plan Review)
25 Applicant has provided a colored elevatIOn draWIng with color chips. Provide
a mounted colored elevatIOn draWIng for the PlannIng and Development
Board meetIng. (Chapter 4 - Site Plan Review)
26 Indicate the locatIOn of the fire hydrants and site lighting and label them on
the landscape plan. There appears to be conflicts between landscapIng, site
lightIng and fire hydrant placement. (Chapter 75, ArtIcle II, Landscape
Code)
27 The drive aisle directly east ofBUlldmg 1 encroaches Into the 40-foot
landscape buffer cuttIng it off at the corner ReVise the deSign of this area to
prevent the encroachment or request/attaIn variance for relief. (Chapter 23 -
ParkIng Lots.)
28 Provide typical parkIng stall detaIl draWIng.
29 DimenSIOn width of all driveways at Intersection with the property lIne.
30 The labels "RR" and "PW" are not Included in materials table on landscape
pian/detail sheet.
31 Show and proVIde reqUired landscapIng around site slgnage.
32 Provide sign colors on detaIl drawing.
33 New bUildIng slgnage shall conform to color recommendatIOns from the
Quantum Park Architectural ReView Committee (e g. white letterIng, green
rather than black, and project trim color rather than orange as proposed).
Provide wall slgnage color detaIls as part of the rectified resubmlttal.
34 A total of three (3) freestandIng signs are proposed for the Site, one for each
of the three bUildIngs. In additIOn, typical wall sign designs were submitted
as a separate 11 Inches x 17 Inches color draWIng labeled 2 0 The signs as
presented are consIstent With the approved Quantum Master Sign Program.
PrOVide a scaled detail draWIng of the typICal wall signs on sheet A-2 of the
site plan package The permitted square footage for wall signs IS 1 5 square
feet for each one (I) foot of lInear bUildIng bay frontage
JlSHRDA TA\PLANNlNGISHARED\WP\PROJECTSIQUA."ITUM 2000ILOTS 32 38\2ND REVIEW COM~ENTS.DOC
2nd Review Comments
ProJect name QUANTUM BUSINESS CENTER (LOTS 32-38)
File number NWSP 00-001
Reference 2nd Review. File # NWSP 00-001 With a February 22.2000 PlannIng and Zonmg Department date
stamD marking
DEPARTMENTS INCLUDE REJECT
PUBLIC WORKS
Comments
1 It IS the opInIOn of the Public Works Departmeoo hat the dumpster enclosure
locatIOns need to be turned 10 to 20 degrees towa:ki the traffic flow for
maximum service It IS also our opInIOn th~~e trally located compactors,
by reducmg the number of receptacle~ftMl w uld tter service thiS proJect and
be more cost effective In the long n.
UTILITIES
Comments.
2. All utility easements shall be shown on the rectified landscapIng draWIngs so
that the Utility Department may determIne which trees may Interfere With
utilities. In general, palm trees will be the only tree species allowed Within
utility easements. Canopy trees may be planted outSide ofthe easement so
that roots and branches will not impact those utIlities Within the easement In
the foreseeable future. LDR See 7.5-18 1 gives public utilities the authority
to remove any trees that Interfere With utility services, either In utilIty
easements or public rights-of-way
3 Dept. of Health permits may be reqUIred for the water and sewer systems
servIng thiS prOJect, (Sec 26-12)
4 Fire flow calculations Will be reqUired demonstratIng the City Code
requirement of 1500 g.p.m. as stated In LDR Chapter 6, Article IV, Section
16, or the reqUIrement Imposed by Insurance underwriters, whichever IS
greater (see Section 26-16(a)). Please submit these calculations With your
Health Department permit submittal.
5 LDR Chap 6, Article IV, Sec 16 reqUIres that all pOInts on each bUIldIng
Will be wlthm 200 feet of an eXisting or proposed fire hydrant. Please
demonstrate that the plan meets thiS conditIOn by shOWIng all hydrants and
necessary dimenSIOns.
6 The waste stream from all manufacturing processes must meet the City'S
pretreatment reqUIrements A sampling pOInt must be provided to allow
mOnItorIng of an V waste stream. (Sec 26-143,26-147)
FIRE
2nd Review Comments
Project name QUANTUM BUSINESS CENTER (LOTS 32-38)
File number' NWSP 00-001
Reference' 2nd Review. File # NWSP 00-001 with a February 22.2000 PlannIng and Zoning Department date
stamp markmg.
DEPARTMENTS INCLUDE REJECT
PUBLIC WORKS
Comments. //
It IS the opInIOn of the Public Works Department that the dumpster enclosure .d:C f\ <flV' P""-
I (~.9y<-: ;) ~e
locatIOns need to be turned 10 to 20 degrees toward the traffic flow for V ~\<1.
maximum service It is also our opinion that a centrally located compactorS; . - / ~ !- /
1"r1\ '7 ,'--'I ~ ~I --.
would better service thiS proJect and ~ be more cost effective in the long _V'_
run. ~
UTILITIES
Comments.
2 All utility easements shall be shown on the rectified landscaping drawmgs so
that the Utility Department may determIne which trees may Interfere With
utilities. In general, palm trees will be the only tree species allowed WithIn
utilIty easements. Canopy trees may be planted outside of the easement so
that roots and branches will not Impact those utilities wlthm the easement In
the foreseeable future LDR Sec 7.5-18 1 gives public utilIties the authOrity
to remove any trees that interfere With utility services, either In utility
easements or public rights-of-way
3 Dept. of Health permits may be reqUired for the water and sewer systems
serving thiS orOJect. (Sec. 26-12).
4 Fire flow calculations wIll be reqUired demonstrating the City Code
reqUirement of 1500 g.p.m as stated in LDR Chapter 6, Article IV, SectIOn
16, or the reqUirement Imposed by insurance underwriters, whichever IS
greater (see Section 26-16(a)) Please submit these calculatIOns With your
Health Deoartment permit submittal.
J tl~~ (\.
5 LDR Chap 6, Article IV, Sec 16 requires that all pOJ on each bUildIng ~5~~ ~y
Will be WithIn 200 feet of an eXistIng or proposed fi hydrant. Please Q. I\c-
demonstrate that the plan meets thiS condltI~~1;1K shOWIng all hydrants~ c:;..-n
~
6 The waste stream from all manufacturing cesses must meet the City's
pretreatment reqUirements. A samplIng pOInt must be provided to allow
momtoring of an v waste stream. (Sec 26-143,26-147)
FIRE
[
'6--<: (c~ J
~ 0'-5
Page 2
Quantum BusIness Center - Lots 32-38
FIle No NWSP 00-001
DEPARTMENTS INCLUDE REJECT
Comments
7 Show F.D ConnectIOns.
8 Hydrants and access roads must be In place pnor to above grade constructIOn.
NFP A 1
POLICE
Comments.
9 ^ ..J. " , N" ~ Y /...1 r - -F. /
Ul"I" <II" u ~~HV ~~ -r T'I'- 1- - {
...., .. ..'
. ,~v u,vu, un U..; OllL" I-Ila.l1. ,.F
s~~ 'fyi' r:R-L /'
C V~, -(y~ ( fn a:. < e <. ('.~ S C <./YV\ U\A ~." -f-.
ENGINEERING DEPARTMENT
Comments
10 Abandon that portIOn of the recorded 10-foot utility easement between lots
32 & 33 to accommodate the new construction.
11 Abandon that portIOn ofthe recorded 10-foot utility easement between lot 38
and lots 36 & 37 to accommodate the new constructIOn.
12 Any fill operation shall reqUire an excavatIOn/fill permit.
13 On the CIVil plans at the time of permittIng, Indicate the clear Sight triangles
for the two Gateway Boulevard driveways. .-
14 The maximum driveway Width IS 32 feet. ObtaIn an approva~or the south -...... . f1::c-+Z 'J) e ~('''frr ~~.{
driveway along Quantum Blvd':" rLDR Chapter 23, Article II.H.l 1
{}- ~") Y pre. v,J:.< r'\~~"(" 62<. .vlet-\S";OIJ;\../ ,/
~c'-.s~
G-- {- (J ( r+;- /.-), Co r
15 Show all traffic control slgnage and markIngs on the site plan. "'F
16 Provide a note on the CivIl plans that the site development will match eXistIng
penmeter grades.
17 Show Unity of Title for all 8 lots.
BUILDING DIVISION
Comments.
Page 3
Quantum BusIness Center - Lots 32-38
FIle No NWSP 00-001
DEPARTMENTS INCLUDE REJECT
Comments
I'
18 The submitted site plan and survey depict two of the three bUildIngs beIng ek'(J, ,
constructed withIn an easement. Before permit reView, submit a copy of the \e..~oc_-l
recorded City resolutIOn that verifies the easements have been abandoned~c:X"'
19 At time of permit submittal, provide a completed and executed City UnIty of ~ 6-. '\ ~t J ~-l'^ F--
e0- s~
title form The form shall describe all lots, parcels or tracts combIned as one
lot. A copy of the recorded deed for each property that IS beIng UnIfied IS
required to process the form. Each recorded deed shall Include a legal
descnptlOn and the owner Identified on each deed shall match.
20 At time of permit review provide detaIled draWIngs and documentation on
the plans that wIll venfy the accessible route from the accessible parking
spaces to the accessible building entrance IS In compliance with the
regulatIOns of the FlOrida Accessibility Code for BUildIng ConstructIOn. The
documentatIOn shall Include, but not be limited to, IdentifyIng the type of
material, surface finIsh, Width, cross slope, slope and length of the entire
accessible route mcIudIng, where applicable, landIngs, ramps and handraIls.
21 Compliance with the BUlldmg codes Will be evaluated at time of permit
review The Permit fee, water and sewer faCIlity fees, Fire and Life Safety
fees, County fees and State fees wIll be determIned at time of permit review
22. Permits are reqUired to construct the Improvements that are shown on the
approved site plan. Permit application forms are available In the BuildIng
DIVISion of the Development Department. A permit submittal checklist IS
aVailable m the BUilding DIVISion. The lIst Identifies the baSIC documents
that the Plans Analyst checks for when an applIcant submits for plan review
PARKS AND RECREA nON
Comments. NONE
FORESTER/ENVIRONMENTALIST
Comments
23 The topographic survey of the site indicates eXistIng trees which should be
Identified, and shown to be preserved in place, relocated or removed/replaced
on the site ThiS should be completed on the landscape plan.
PLANNING AND ZONING
Comments.
~~
.....\5
Page 4
Quantum Busmess Center - Lots 32-38
fIle No NWSP 00-001
\ ~v' evs(a,
DEPARTMENTS
INCLUDE REJECT
. ...'Yl.d-- 0
24 Provide traffic controwar p-a:nd slgnage for the vehicular use areas on
the site plans (Stop signs, dlrectIona~lgns etc) (Chapter 4 - SIte Plan
ReView a ~J!
25 ApplIcant has provided a colored elevatIOn draWIng With color chips. Provide
a mounted colored elevation draWIng for the PlannIng and Development
Board meetmg. (Chapter 4 - Site Plan Review)
BUildIngs 1 and 3 are located on eXistIng utilIty easements Either move the
bUlldmgs or relocate these utility easements. (Chapter 4 - Site Plan Review)
II. (\ C% C
JL <i~
27 Indicate the locatIOn of the fire hydrants and site lightIng and label them on
the landscape plan. There appears to be conflicts between landscaping, site
lightIng and fire hydrant placement. (Chapter 7,5, Article II, Landscape
Code. )
The driveway openIng located west of BUildIng 2 has a dimenSIOn greater
than the maximum permitted 32 feet. Indicate the exact dimenSIOn of this
driveway on the site plan. Approval is reqUired for thiS driveway Width.
Cha ter 23 - ParkIn Lots
~<::.
Cl~
Jq,
29 Label the dimension for the driveway throat for the maJor driveway entrance
on uantum Blvd. Cha ter 23 - ParkIn Lots
30 The drive aisle directly east of BUll dIng 1 encroaches into the 40-foot
landscape buffer cutting it off at the corner ReVise the deSign of this area to
revent the encroachment. Cha ter 23 - Parkin Lots.
31 A total of three (3) free-standmg signs are proposed for the Site, one for each
of the three buildIngs. In addition, typical wall sign deSigns were submitted
as a separate 11 mches x 17 mches color draWIng labeled 2 0 The signs as
presented are consistent With the approved Quantum Master Sign Program.
Provide a scaled detail drawing of the typical waIl signs on sheet A-2 of the
site plan package. The permitted square footage for wall signs IS 1 5 square
feet for each one 1 fo of II ar buildm ba fronta e
neV- P rei\) < . p~ ~(t-. rn ~ ~/( c:C=- ~ ( d QL wE n
J-ISHRDA T A\PLA!\'NINGISHARED\Wp\p1oJECTSIQUA!\,UM 20'ot\LOTS 32 38\2ND REVIEW CO~illENTS.DOC Y
L ""-<' Cc S <..~ t!!:I j {'(\ I /
: f -- ~one.", s ~~ 'f\ ...~ ~ ;}S ~~cfle
I~ re"i'-' re ~~ c t. t
2C-rv\....-'1" ~..L "J a...1:;7 j c.v ~..C 6-Ll1<6.C:=<o'-f ~ ~ I<!""S ;~iL-r;Q(
J ".:5 7' iq ?-r;, v - ~ C\. .",/:. / '" /1 j .If'
bb~..J( .l~~~~~::-~ \~ (,:f-I' J 70 0/clf.P4J(r'.... c:r \.:-l<./~~ffF-,.Q
p.t:: ~ (L (~uJ 6- c2S i:r,4 G u.fP-<-
~- ~~:pd[(,,,~~~ ~~_~(( COC(:~Ys:.~_~_,"(ccs~~f1oA/~ ~
In sc:.'-f
lI1eW
IJ{ e,\c:z:. o-s
"'fa ,/ 'P1 (y\1 ~
lhG- I ~&. C-- (s '1- Ii 6- .... JL ,"'P w" <$ ( <- '(\<=t
1_ '" c.1 v s~ ,/.... jV'l "- -{<--, ,h +M,,- Cl"- I... .d2s Gf e
~/a.'" ~"-~,( 5L~+ \/
\) _ ~ s ~~/ \' f~u ,.-.0<:.. .e"t~; ,J (4....( 5"~-'>y
(f'. <' ev.... .Q '0, / ft.- 5 ~ n?{/ 0
.<=..0 --
~<(w.IJ\,= $(J~. Ccl=f5 OJ-dY~(.sIcf)rowl"Y"
~S-3--J'~ (~ 0
.. /_.. .- _..- ......----_. .-. --------- --
Page 4 ~~ \lUSt
Quantum Business Center - Lots 32-38
File No NWSP 00-001
.;
DEPARTMENTS
INCLUDE REJECT
24 Provide traffic control and flow markIng and slgnage for the vehicular use
areas on the site plans (Stop Signs, directIOnal flow and signs etc.) (Chapter
4 - Site Plan ReView
25 ApplIcant has provided a colored elevation draWIng with color chips. Provide
a mounted colored elevatIOn draWIng for the PlannIng and Development
Board meetIng. (Chapter 4 - Site Plan Review)
26 Indicate the locatIOn of the fire hydrants and site lightIng and label them on
the landscape plan. There appears to be conflicts between landscapIng, site
lightIng and fire hydrant placement. (Chapter 7 5, Article II, Landscape
Code. )
The driveway openIng located west of BUilding 2 has a dimension greater
than the maximum permitted 32 feet. Indicate the exact dimenSIOn ofthls
driveway on the site plan. Approval IS reqUired for thiS driveway Width.
Cha ter 23 - ParkIn Lots
28
30 Provide typical parkIng stall detail draWIng.
31 DimenSIOn Width of all driveways at IntersectIOn with the property lIne
32 The labels "RR" and "PW" are not Included In materials table on landscape
lan/detail sheet.
33 Show and provide reqUired landscapIng around site slgnage.
34 Provide sign colors on details draWIng,
35 A total of three (3) freestandIng signs are proposed for the Site, one for each
ofthe three bUildings. In addition, typical wall sign deSigns were submitted
as a separate 11 Inches x 17 Inches color draWIng labeled 2.0 The signs as
presented are consistent with the approved Quantum Master Sign Program
Provide a scaled detail draWIng of the typical wall signs on sheet A-2 of the
site plan package. The permitted square footage for wall signs IS 1.5 square
feet for each one 1 foot of linear buildIn ba fronta e
J ISHRDAT A\PLAl\'NIKGISHARED\WP\PROJECTSIQUANTUM 2000ILOTS 32 38\2ND REVIEW COMMENTS.DOC
c
?~~~P~~
~ -0 f 1 ~ .. 0\
~1 ~: ~' 1 ~ h S\
I;\- "" ,r _.:1
." /\-- ~ "
" ~ t t -;\.V\ i.
\.. ~ P ~ r r';. :S
, r-...... '-"\
--0 \} (\ ~
t ~. '-"' .G')~
-0 \; I C
_)t. f1 (J\
Co (1) }-? f'..
~. $ t~' r~,
~ 3' r '1 ~,
~ ~ 0 ~ ,,0 ~
~ ~t~fc1"
r ~ 7
t t~'ft
b ::>'"' f';
, ~W\ 1-)..
~ ~lJI, ~ :f' 7\f. t ;..r 0
~,~~'J b 'J
n--. ~ >- ~ 3;
1...' ") "\ "
~~1+-r;
-r t ~ (\
~ (\ ~ f/ ~
~ ~~ t- f
~ V\
Page 4
Quantum BusIness Center - Lots 32-38
FIle No NWSP 00-001
~a VLt01A
DEPARTMENTS
INCLUDE REJECT
24 Provide traffic control and flow markIng and slgnage for the vehicular use
areas on the site plans (Stop signs, directIOnal flow and signs etc) (Chapter
4 - Site Plan ReView
25 ApplIcant has provided a colored elevation drawmg with color chips. Provide
a mounted colored elevation draWIng for the PlannIng and Development
Board meetIng. (Chapter 4 - Site Plan Review)
26 Indicate the location of the fire hydrants and site lightIng and label them on
the landscape plan. There appears to be conflicts between landscapIng, site
IIghtmg and fire hydrant placement. (Chapter 7 5, Article II, Landscape
Code. )
~
1~1
z( The drive aisle directly east of BuildIng 1 encroaches Into the 40-foot
landscape buffer cuttmg it off at the corner ReVise the design of thiS area to
revent the encroachmen Cha ter 23 - ParkIn Lots.
~............~....... ~--
Provide typICal parkmg stall detail draWIng.
DimenSIOn width of all driveways at Intersection with the property lIne.
The labels "RR" and "PW" are not mcluded In materials table on landscape
Ian/detaIl sheet.
/: ,]
.' --, I;
....... "V'-- _-I:. '
lJ
2{ ~
r,'l ;M
lJ. '\ .J{
,., i ~
1 '
3
)(
3
,
)
Show and provide reqUIred landscaping around site slgnage
r
Provide sign colors on detalJj drawing.
New buildIng slgnage shall conform to color recommendatIOns from the
Quantum Park Architectural ReView Committee (e.g. white lettering, green
rather than black, and proJect trIm color rather than orange as proposed).
PrOVide wall Sl na e color details as art of the rectified resubmlttaI.
35 A total of three (3) freestanding signs are proposed for the Site, one for each
of the three bUIldIngs. In addition, typical wall sign deSigns were submitted
as a separate 11 Inches x 17 Inches color draWIng labeled 2 0 The signs as
presented are consistent with the approved Quantum Master Sign Program
Provide a scaled detail draWIng ofthe typical wall signs on sheet A-2 ofthe
site plan package The permitted square footage for wall signs IS 1.5 square
feet for each one 1 foot of linear buIldIn ba fronta e
J ISHRDATA\PLANNINGISHARED\WP\PROJECTSIQUANTUM 2000ILOTS 32 38\2ND REVIEW cm1MENTS.DOC
2nd Review Comments
ProJect name' QUANTUM BUSINESS CENTER (LOTS 32-38)
File number NWSP OO-O~~ Vii.--' ~ te bvvotf ;2.2.- J
Reference' 2nd Review. File # NWSP 00-001 with a JMlLU1, bL 2000 Planning and Zoning Department date
stamp marking.
2.
I DEPARTMENTS INCLUDE k'1-< II-<' I
PUBLIC WORKS
I. rt- IS lk- Of\~tu.'Y\ 6-t- 41iL t"w!i.... W5f2-t.S '~f-'{'fntt..f- ~'1he /'~dlre~ 6,
Comments. I CU,IIAPS-k',l. e~1do::'lJ.e... lo(,2hm~ hf'<t;\ +r> be +C.e.n~ \Dto ')j) k,( I..k.e.
v iY4...ff-~ ':t!.c'-V 1:- rnaJL[flU0n SeJl.t..-Iu-" ,n IS 2-lso DL:.~ Dftrl LiI).o)V tv)~.:L ~ e 1--'/7 2.L.L.lj
UTILITIES \oc 2.k'c~ M"'fa d /M::l..:Jd be I/t?i ~bl(e '-t~ fY6Jld uv0.. W ...J 01.. be l'hatc. l c,"-t- e#ec.-hW'
III 'tt<. I,,~ ~. '-'
Comments.
..Y All utilIties easements shall be shown on the rectified landscapIng drawIngs
so that utilIties may determme which trees may Interfere With utilities In
general, palm trees wIll be the only tree species allowed WithIn utilIty
easements. Canopy trees may be planted outside of the easement so that
roots and branches will not Impact those utIlities WithIn the easement In the
foreseeable future LDR Sec 7.5-18 1 gives publIc utilities the authonty to
remove any trees that Interfere With utilIty services, either In utilIty
easements or public nghts-or way
,~ Dept. of Health permits may be reqUired for the water and sewer systems
servIng thiS proJect. (Sec 26-12)
y Fire flow calculatIOns Will be reqUired demonstrating the City Code
reqUirement of 1500 g.p.m as stated m LDR Chapter 6, Article IV, SectIOn
16, or the reqUirement imposed by Insurance underwriters, whichever IS
greater (see Section 26-16(a)). Please submit these calculatIOns With your
Health Department permit submittal.
.r LDR Chap 6, Article IV, Sec 16 requires that all pOInts on each bUildIng
wIll be WithIn 200 feet of an eXistIng or proposed fire hydrant. Please
demonstrate that the plan meets thiS conditIOn, by showmg all hydrants.
.Y The waste stream from all manufacturIng process must meet the City'S
pretreatment reqUirements. A samplIng pOInt must be proVided to allow
monitorIng of any waste stream (Sec. 26-143, 26-147)
FIRE
Comments.
if' Show F.D ConnectIOns
/; Hydrants and access roads must be In place prior to above grade
construction. NFP A 1
POLICE
Comments '1 Af-~ ,1trt\e.. ~/le ere.. f10 rOr-ttWj n.2-I'-t.[~S ar '51 ~ (1tv0
1'o:>-14,,c.. ...J).bl-v {b,-/lcfl""- VV'A1t\-q I <'tU<.. ,?fGli.d.Q ~.a.\l.t(Q
v I
ENGINEERING DIVISION
J
'1
r;
(p
7
<6,
1
1-~
/'P
Page 2
Quantum Busmess Center - Lots 32-38
FIle No NWSP 00-003
DEPARTMENTS
Comments.
/D ~
Abandon that portion of the recorded 10- foot utilIty easement between
lots 32 & 33 to accommodate the new constructIOn.
/)
>/
Abandon that portIOn of the recorded 10- foot utility easement between lot
38 and lots 36 & 37 to accommodate the new constructIOn.
(J--
/},
16
Any fill operation shall reqUire an excavatIOn/fill permit.
On the civIl plans at the time of permlttmg, Indicate the clear sight
triangles for the two Gateway Boulevard driveways.
/1/
f~
M Show all traffic control signage and markings on the site plan.
.>5 Provide a note on the civIl plans that the site development wIll match
eXlstmg perimeter grades.
/1
y( Show Unity of Title for all 8 lots.
BUILDING DIVISION
Commehts
,~ "J- u
PARKS AND RECREATION
Comments. NONE
FORESTERlENVIRONMENT ALIST
Comments.
~ The topographic survey of the site Indicates eXistIng trees which should be
Identified, and shown to be preserved In place, relocated or
removed/replaced on the site This should be completed on the landscape
plan.
PLANNING AND ZONING
Comments.
~~ ~
ProVide traffic control markIngs and slgnage for the vehicular use areas
on the site plans (Stop signs, directional signs etc). (Chapter 4 - Site
Plan Review)
pMO- ~ rr.tJ-1J,..'Y~
(l.NI$lsJtJ 0
INCLUDE REJECT
~
Page 4
Quantum Busmess Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS
INCLUDE REJECT
3
M
:}II
A total of three (3) free standIng signs are proposed for the Site, one for
each of the three bUlldmgs. In addition, typical wall sign deSigns were
submitted as a separate 11 Inches x 17 Inches color drawing labeled 2 0
The signs as presented are consistent with the approved Quantum
Master Sign Program ProVide a scaled detaIl draWIng of the typical wall
signs on sheet A-2 of the site plan package The permitted square
footage for wall signs IS 1.5 square feet for each one (1) foot of linear
bUildIng bay frontage
J-ISHRDATA\PLANNINGISHARED\\l/P\PROJECTSIQUAI'.'TUM 2000ILOTS 32 38\21'.'0 REVIEW COMMENTS DOC
1 st REVIEW COMMENTS
/~( frs~
ProJect name'
File num~r-
Referenc~
stamo markInI!.
QUANTUM BUSINESS CENTER (LOTS 32-38)
WSP 00-003 .~_ II
eVlew File # NWSP 00-001 with a JaRMan 1 t. 2000 PlannInI! and ZonIn De artment date
DEPARTMENTS nd ~C: (J INCLUDE REJECT
lth ~ l /1\" ~
PUBLIC WORKS - ~%, ()Y ~J,<<-i .n \ OJ
v '-..,) \"
Comments.
UTILITIES
Comments
I'J) All utilities easements shall be shown on the rectified landscapIng
'"-, drawings so that utilities may determIne which trees may interfere With
utilities. In general, palm trees will be the only tree species allowed
WithIn utility easements. Canopy trees may be planted outside of the
easement so that roots and branches will not impact those utilities WithIn
the easement in the foreseeable future LDR Sec. 7.5-18 1 gives public
utilities the authOrity to remove any trees that Interfere With utility
services, either In utility easements or public rights-or way
@ Dept. of Health permits may be reqUired for the water and sewer
systems serving thiS project. (Sec. 26-12)
0> Fire flow calculations will be required demonstrating the City Code
reqUirement of 1500 g.p.m. as stated In LDR Chapter 6, Article IV,
Section 16, or the requirement Imposed by insurance underwriters,
whichever IS greater (see SectIOn 26-16(a)). Please submit these
calculatIOns With your Health Department permit submittal.
)( .-
SectIOn 26-34(E) of the City Code reqUires that a capacity reservatIOn
fee be paid for thiS proJect either upon my request for signature on the
Health Dept. applicatIOn forms or wlthm 30 days of site plan approval,
whichever occurs first. ThiS fee Will be determIned based upon final
meter Sizes, or expected demand.
l)\ Comp Plan policy 3C.3 4 requires the conservatIOn of potable water
City water may not, therefore, be used for lITIgatIOn where other sources
are readily available
)( Water and sewer lInes to be owned and operated by the City shall be
Included WithIn utility easements. The easements shall be dedicated via
separate Instruments to the City as stated In Sec 26-33(a) of the Code
X Utility Department will not reqUire surety for InstallatIOn of the water
and sewer utilities, on condition that the systems be fully completed, and
given to the City before the first permanent meter IS set. Note that
settIng of a permanent water meter IS a prereqUisite to obtaInIng the
certificate of occupancy
Page 2
Quantum BusIness Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
0 LDR Chap 6, Article IV, Sec. 16 requires that all pOInts on each
bUildIng will be withIn 200 feet of an eXistIng or proposed fire hydrant.
Please demonstrate that the plan meets this conditIOn, by showing all
hydrants.
K A bUildIng permit for thiS proJect shall not be Issued until thiS office has
approved the plans for the water and/or sewer Improvements reqUired to
serve the proJect. (Sec 26-15)
8 The waste stream from all manufacturing process must meet the City'S
pretreatment requirements. A samplIng pOInt must be provided to allow
mOnItorIng of any waste stream. (Sec 26-143,26-147)
FIRE
Comments. MUU SJ1(){,J Fv D6Yl~S ,
)( A fire flow test IS reqUired prior to constructIOn. LDR 6-16
:K0 Hydrants and access roads must be In place prior to above grade
construction. NFP A 1
POLICE
Comments.
13 At thiS time there are no roadway markIngs or traffic flow pattern
markIngs. I do foresee a couple of problem areas that will need to be
addressed before final approval.
ENGINEERING DIVISION .
Comments.
~ On the Site Plan add a general note that all plans submitted for specific
permits shall meet the City'S code reqUirements at time of application.
These permits Include, but are not limited to the follOWIng: site lightIng,
pavIng, draInage, curbIng, landscapmg and lITIgation. Permits reqUired
from other permittIng agencies, such as FDOT, PBC, SFWMD, DERM,
L WDD, DEP and any others, shall be Included with the permit request.
(0 Abandon that portIOn of the recorded 10 foot utility easement between
lots 32 & 33 to accommodate the new constructIOn.
to Abandon that portIOn of the recorded 10 foot utility easement between
lot 38 and lots 36 & 37 to accommodate the new constructIOn.
X Provide a general note on sheet 4 of the pavIng and draInage plans that
the exfiltratlOn system shall conform to City Standard Drawmg B-91007
Page 3
Quantum BusIness Center - Lots 32-38
File No NWSP 00-003
~.j\~
DEP AR TMENTS INCLUDE REJECT
6Q Any fill operation shall require an excavatIOn/fill permit.
~ Show the draInage plan at the same scale as the site development plan.
[LDR Chapter 4, SectIOn 7.F ]
~ On the SIte and civil plans show the 5 foot concrete Sidewalk through
both driveways along Gateway Blvd. with a minImum thickness of 6"
[LDR Chapter 23, Article H.P]
){ On the site and civil plans add a general note that all stripIng, markIngs
and sIgnage shall conform to City Standard DraWIng B-91007 and
reflect all stripIng, markIng and slgnage on both plans. [LDR Chapter 4,
Section 7.B ]
7Y( Show proposed lightIng on both the landscape and civil plans for
InspectIOn purposes and possible shadIng of parkIng lot areas. [LDR
Chapter 4, SectIOn 7.B ]
@> C lV.d oJ- -hrne by- pel2t'l1l+tll~ '
On the site ~lRd laRdseape planMndlcate the clear sight trIang~r the
two Gateway Boulevard driveways.aRd at tHe QHaAtHm. .QoHlevard
Interseetlo8 as specIf~ed 19 fDOT Inekx 546
X On the site and landscape plans Indicate the clear sight triangles along
the four Quantum Blvd. driveways USIng the 35 foot legs of the triangle
as specified In LDR Chapter 7.5, Article II, SectIOn 5.H.2.
X On the landscape plans add a general note that the landscapIng withIn
the safe sight triangles shall have a clear, unobstructed cross-visibility ....
between 30 Inches and 6 feet above the pavement. [LDR Chapter 7.5, .
ArtIcle II, SectIOn 5.H.]
~ On the site and civil plans show a five foot concrete Sidewalk along
Quantum Blvd. to the limits of the site or obtain a waiver therefrom
[LDR Chapter 22, Article I, SectIOn 5 & Chapter 6, Article IV, Section
lOt.]
27 Reduce the driveways along Quantum Blvd. from four to two per code
or obtaIn a variance therefrom [LDR Chapter 23, Article I, SectIOn 3.B
& Article II.H.7 & LDR Chapter 2, Section 7.H.3 ]
~ On the site and civil plans show the 5 foot handicap accessible paths
flush through the Sidewalks with a ramp up on either Side per Florida
Accessibility Code (8 places)
29 The maximum driveway Width IS 32 feet. ObtaIn an approval for the
south driveway along Quantum Blvd. [LDR Chapter 23, Article II,H.I ]
(tQrv ShoLU ~ fr11-11!-- can~ ~11~.e oott >>1Zt:lqnjf (JY1 We [;de flM
Page 4
Quantum BusIness Center - Lots 32-38
File No NWSP 00-003
x
fo-? @
~
~
p(
x
~
't
~
DEPARTMENTS
Remove the reference to a "tow away zone" on the handicap post sign.
See Standard Drawing B-9800 1
On the paVIng and drainage plan Identify the 4 sheets on the locatIOn
map for reference purposes.
Specify a 12 Inch mInimum subgrade thickness on the "typical
pavement on Sheet 4 of 4 of the cIvil draWIngs.
Correct the elevatIOn call outs of BUildIngs # 1 & #2
Clarify use of eXistIng 48inch CMP at BuildIng #3
Show UnIty of Title for all 8 lots.
M
Locate the handicap post sign withIn the landscape areas behInd the
sidewalk.
In lieu of wheelstops and the asphalt between them and the 5 foot
sidewalks along the buildIngs, construct 7 foot sidewalks incorporatIng
the edge of curb as a contInUOUS wheelstop ThiS reduces maIntenance
and the potential trippIng hazards on IndiVidual wheelstops.
On the pavIng and draInage plan specify that the 11/2 Inch of asphalt be
done In two lIfts.
The mInimum average lightIng withIn the parkIng areas may be one foot
candle subJect to the speclfic~tlOn In LDR Chapter 23, Article I1.A.
BUILDING DIVISION
Comments.
42~ Ann tn the 1:l1:1ileling(s) that <lIC depicled on the drawing titled site plan a
INCLUDE REJECT
fl,.d)d1 .,fx li 1\.,9
pee/lhe-fe.t 't22der
Page 5
Quantum Business Center - Lots 32-38
Fde No NWSP 00-003
DEP ARTMENTS
labeled symbol that Identifies the locatIOn of the handicap accessible
/
entrance door to the each tenant space. Show and label the same door(s)
on the drawIng titled partial floor plan. /
I
43 Add a labeled symbol to the drawIng that IS titled site pl~. The symbol
shall represent and delIneate the path of travel of the aressible route
that IS reqUired between the accessible parkIng spacef and the
accessible entrance doors to each tenant space Ide 'tIfy on the plan the
Width of the accessible route. (Note The mInim width reqUired by
the code IS forty-four (44) Inches). Add text th would Indicate that the
symbol represents the accessible route and the oute IS designed In
compliance With SectIOn 4.3 (Accessible Ro e) and 4 6 (ParkIng and
Passenger LoadIng Zones) ofthe Florida cessibllIty Code for
BUildIng ConstructIOn. The symbol will present the locatIOn of the
path of travel, not the location of the det ctable warnIng or other
pavement markIngs that are required t be Installed along the path.
Please note that at time of permit rev w the applicant shall provide
detailed documentatIOn on the plan hat will venfy that the accessible
routes are In compliance With the gulatIOns specified In the FlOrida
Accessibility Code for Building onstructlOn.
44 WithIn the site statistics foun on the cover sheet and sheet A-I,
Identify the proposed finIsh oor elevatIOn of the bUildIng (lowest floor
elevatIOn) Verify that the roposed elevatIOn complies With regulatIOns
of the code by addIng spe IficatlOns and notes to the site data that
address the follOWIng IS es.
a) From the FIRM map identify the title of the flood zone that the building is
located within. re applicable, specify the base flood elevation. If
there is no base fl od elevation, indicate that on the plans.
b) As the deSIgn ofesslOnal-of-record for the proJect, state that the
proposed floo elevation is above the highest 1 OO-year base flood
elevation ap icable to the bUildIng Site, as determIned by the South
FlOrida Wa er Management DistriCt's surface water management
construct I n development regulatIOns. [SectIOn 3107 1.2, Chapter
31 of th oynton Beach amendments to the 1997 editIOn of the
Standar. BuddIng Code]
c) Identl the floor elevatIOn that the deSign profeSSional has
esta ished for the buildIng WithIn the footprInt of the buddIng that
IS s own on the Site plan, floor plan and Civil plan
42 Add e follOWIng notes to the site plan that depicts the proposed
IOn of the site lightIng poles/fixtures.
State that the locatIOns of the site lightIng poles are conceptual
State that the site lightIng Will be evaluated for code compliance at
time of permit review
State that the proposed site lighting fixtures will illumInate the site
consistent With the specificatIOns Identified In the ParkIng Lot
Code.
d) Identify the overall height dimenSIOn of the site lIghtIng pole and
INCLUDE REJECT
Page 6
Quantum Business Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS
fixture (Note The overall height of the pole/fixt re shall not
exceed the height limitations of the ZonIng Cod .)
Omit the pole lightIng photometric Information a drawIng. This
InformatIOn IS reqUIred at time of permit subml I, not at site plan
review
INCLUDE REJECT
43 On the draWIng titled site plan, Identify th
property lIne
44 The submitted site plan and survey d ICt two of the three buildIngs
beIng constructed WithIn an easem t. Amend the plans so that
structures do not encroach Into a easement.
45 Indicate In the site statistics th each buildIng IS one story Indicate the
number of stOries within the ootprint of each buildIng that IS depicted
on the floor plan drawings
46 Below the draWIngs titl a Partial Floor Plan, add text that would
Indicate that the draw g is conceptual.
47 bmIttal, provide a completed and executed City
The form shall describe all lots, parcels or tracts
combIned as 0 lot. A copy of the deed With legal deSCriptIOns of each
property that 's beIng UnIfied IS reqUIred to process the form The
property 0 er that is Identified on each deed shall match.
48 WithIn e site statistics found on the cover sheet and WithIn the site
statis .cs found on sheet A-I, Identify the uses proposed for each
buIl ng.
49 IthIn the site statistics found on the cover sheet, a F-2 occupancy
lasslficatlOn was Identified, however, the 1997 edition of the Standard
BUIldIng Code includIng the City'S amendments to the Standard
BUilding Code do not Identify an F-2 classification. Amend the plans
accordingly
P ARKS AND RECREATION
Comments
NONE
FORESTER/ENVIRONMENTALIST
Comments'
~
The applIcant must submit an environmental assessment of the site Flora
and Fauna. ThiS should be completed as part of the site plan submittal
process.
The existIng gopher tortoises must be relocated off the site prior to the
Page 7
Quantum BusIness Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS
site clearing and grubbIng permit Issuance.
The topographic survey of the site Indicates eXistIng trees which should
be Identified, and shown to be preserved In place, relocated or
removed/replaced on the Site This should be completed on the
landscape plan.
PLANNING AND ZONING
Comments:
\L V For the second submittal, put plans together In one package All plan
I\.. sheets should be 24"x 36" size
V Provide site plan sheets at 1 "=30' scale to match landscape and
engIneering plans.
{
r~ Jl~
Provide traffic control markIngs and signage for the vehicular use areasO
(stop signs, directIOnal signs etc) (Chapter 4 - Site Plan Review)
ApplIcant has provided a colored elevation draWIng With color chips.
Provide a mounted colored elevatIOn draWIng for the Planning and
Development Board meetIng. (Chapter 4 - Site Plan Review)
V ~e north and south elevation draWIngs are mislabeled. Please correct.
/\ ' (Chapter 4, Site Plan Review)
tIV,' / I (.1 r I' ('-1 lot- c. 6 CL '-7. t,! ~ u '-'0v
BuildIngs 1 and 3 are locatec:t'on existing utIlIty easements. Either move
the bUildings or relocate these utility easements. (Chapter 4 - Site Plan
Review)
Indicate the locatIOn and dimension of landscape Sight triangles on the
landscape plan sheets. (Chapter 7.5, Article II, Landscape Code,)
~ ' I
Indicate the locatIOn of the fire hydrants and site lightIng on the
landscape plan. There appears to be conflIcts between landscapIng, site
lIghtIng and fire hydrant placement. (Chapter 7.5, Article II, Landscape
Code )
1( V The driveway openIng located west of BuIlding 2 has a dimensIOn
Y\ greater than the maximum permitted 32 feet. Indicate the exact
dimenSIOn of this driveway on the site plan. Approval is reqUired for this
driveway Width. (Chapter 23 - Parking Lots)
V Label the dImenSIOn for the driveway throat for the maJor driveway
entrance on Quantum Blvd. (Chapter 23 - ParkIng Lots)
~u..
The drive aisle directly east of BUildIng 1 encroaches Into the 40 foot
landscape buffer cuttIng It off at the corner ReVise the deSign of thiS
INCLUDE REJECT
c/
c/
t/
'--"'"
Page 8
Quantum BusIness Center - Lots 32-38
File No NWSP 00-003
DEP ARTMENTS
area to prevent the encroachment. (Chapter 23 - Parkmg Lots.)
Indicate and label the right-of-way lme for Gateway Blvd. and Quantum
Blvd. on the site plan. (Chapter 23 - ParkIng Lots.)
~ VProvlde a continuous concrete sidewalk through the driveway entrances
along Gateway Blvd. (NW 22nd Ave) (Chapter 23 - Parking Lots.)
The site plan Indicates that six (6) driveways are proposed for this
project. No more than two (2) driveways are permitted per street
frontage A variance Will be required to permIt addItIOnal driveways.
(Ch. 23, Art. II, H, 7)
Provide a Sidewalk along Quantum Blvd. (Ch. 6, Art. III, 11)
" Provide pedestrian/handicapped access from the maIn entrance of
BUildIngs 2 and 3 to a Sidewalk along Quantum Blvd. (Ch. 9,Sec 10, B).
hi JThe back of BUildIng 1 faces Quantum Blvd. with a fairly large
'9\. unobstructed viewing area of the bay doors and dumpster enclosures
from the street, particularly at the large major entrance drive. Some
bermIng is provided but does not appear to create a sufficient buffer as
required by Ch. 9 - CommunIty Design Standards or the Quantum
DeSign ReView Guidelines. RedeSign of this area IS reqUired.
INCLUDE REJECT
~
&
if
~f-.
~L
A total of three (3) free standIng signs are proposed for the Site, one for
each of the three bUildIngs. In additIOn, typical wall sign deSigns were
submitted as a separate 11 inches x 17 mches color draWIng labeled 2 0
The signs as presented are consistent With the approved Quantum
Master Sign Program Provide a licaled oet<lil drawing of the typical_wall
slgI:t1> SA shea A 2 of tR8 site plag package. The permitted square
footage for wall signs IS 1.5 square feet for each one (1) foot of linear
buildIng bay frontage
J ISHRDAT A\PLANNlNGISHARED\WP\PROJECTSIQUANTUM 2000ILOTS 32 38\1 ST REVIEW COMMENTS DOC
DEPARTMENT OF DEVELOPMENT
BUILDING DIVISION
MEMORANDUM NO 00-056
.--......,
~
) ->,,;,
MAR - 2 rf'
r
Ilnl!
, . ,
. /I!
! Ii i,
;-1 ! !
RE
Quantum Business Center (Lots 32-38) - New Site Plan
OO~) 2nd review comments
~-~-" .
, ""<4
/.+fl
,1 ~pt'
TO
MIchael Rumpf, Planmng and Zonmg DIrector
FROM
MIchael E. Haag, BUIldmg Code AdmmIstrator
DATE
March 2, 2000
We have revIewed the subject plans and recommend that the request be forwarded for
Board reVIew WIth the understandmg that all remammg comments WIll be shown m
complIance on the workmg drawmgs submItted for permIts
Buildin~ Division (Site Specific and Permit Comments)
1 The submItted sIte plan and survey depIct two of the three bUIldmgs bemg
constructed wIthm an easement. Before permIt reVIew, submIt a copy ofthe
recorded CIty resolutIon that venfies the easements have been abandoned.
2 At tIme of permIt submIttal, provIde a completed and executed City umty oftItIe
form. The form shall describe all lots, parcels or tracts combmed as one lot. A
copy of the recorded deed for each property that IS bemg umfied IS reqUIred to
process the form. Each recorded deed shall mclude a legal descnptIOn and the
owner IdentIfied on each deed shall match.
3 At tIme of permIt reVIew provIde detaIled drawmgs and documentatIOn on the plans
that WIll venfy the accessible route from the accessible parkmg spaces to the
accessible bUIldmg entrance IS m complIance WIth the regulatIOns of the Flonda
AccessibIlIty Code for BUIldmg Construction. The documentatIOn shall mclude, but
not be lImIted to, IdentIfymg the type of matenal, surface fimsh, WIdth, cross slope,
slope and length of the entIre accessible route mcludmg, where applIcable, landmgs,
ramps and handraIls.
4 ComplIance WIth the BUIldmg Codes WIll be evaluated at tIme of permIt reVIew
The permIt fee, water and sewer faCIlIty fees, FIfe and LIfe Safety fes:s, County fees
and State fees WIll be determmed at tIme of permIt reVIew ~
5 PermIts are reqUIred to construct the Improvements that are shown on the approved
SIte plan. PermIt applIcatIOn forms are avaIlable m the BUIldmg DIVISIOn of the
Development Department. A permIt submIttal checklIst IS avaIlable m the Buildmg
DIVISIOn. The lIst Identifies the baSIC documents that the Plans Analyst checks for
when an applIcant submIts for plan reVIew
J \SHRDA T A \Development\Building-6870\Documents\ TRC\NWSP 00-003 2nd review Quantum Business Center (Lots 32 38),doc
PUBLIC WORKS DEPARTMENT
MEMORANDUM #00-039
VIA.
Mike Rumpf, Duector of PlannIng & Zonmg
Chnstme Roberts, Intenm Publ1c Works Duector ct1t"
TO'
FROM
Mark A. LIpS, Sol1d Waste Foreman III
DATE
March 8, 2000
SUBJECT
2nd ReVIew for Quantum Busmess Center - Lots 32-38
File No - NWSP 00-003
It IS the opmlOn of the Public Works Department that the dumpster enclosure location
need to be turned 10 to 20 degrees towards the traffic flow for maXImum serVIce It IS
also our opmlOn that a centrally located compactor would better serVIce thIS project and
would be more cost effective m the long run.
If you have any questlOns please contact me at (561) 742-6200
ML/pl
Facsimile
TRANSMITTAL
CITY OF BOYNTON BEACH
100 E. BOYNTON BEACH BOULEVARD
POBOX 310
BOYNTON BEACH. FLORIDA 33425-0310
FAX. (561) 742-6259
PLANNING AND ZONING DIVISION
TO. Winston Lee & Associates, Inc
FAX #. 689-5559
DATE. February 3,2000
RE: 1 st Review Comments, Quantum Business Center - Lots 32-38
~~
f/
Please find attached the first review comments for your project. To stay on the
current review schedule, please do the following steps listed below, and bring all
documents to the TRC meeting scheduled for
1 Revise your plans incorporating all comments listed herein, including the addition
of notes on plans to confirm response to general statements/comments, and
bring 10 copies to the TRC review meeting (full sets including all pages originally
submitted),
2. Submit the additional information as requested within the attached comments (
i e traffic analysis, engineering certification, etc.)
3 Prepare a written response (7 copies) consisting of a list briefly summarizing how
each comment has been addressed on the revised plans or with the
supplemental information including location on the plans (this promotes an
expeditious 2nd review by staff and your project representatives during the TRC
meeting), and
4 Submit reductions (8 % x 11) for the proposed site plan, elevations and
landscaping plan (this is required for the final report and public presentation)
The applicant should not attend a TRC meeting (2nd review) until all documents have
been revised and copied for staff review
Page 1 of
Planning and Zoning DiviSion
City of Boynton Beach
Boynton Beach, Flonda 33425
742-6260
Fax: 742-6259
If plans will not be fully revised and brought to the scheduled TRC meeting, contact
JoAnn Alea in this office by the Thursday prior to the schedule meeting date Projects
deviating from the original schedule are eligible for review at subsequent meetings,
which are held every Tuesday To reschedule, contact JoAnn Alea by the Thursday
prior to the Tuesday TRC meeting that you desire to attend. The remainder of the
review schedule will be adjusted accordingly If you have questions on the attached
comments, please contact the respective reviewer using the attached list of TRC
representatives.
If the plans are reasonably complete and all significant comments are addressed
following TRC (2nd review), the project is forwarded to the Planning and Development
Board meeting that falls approximately 2 to 3 weeks following the TRC meeting An "*"
by any comment identifies a comment that must be addressed prior to moving forward to
the Planning and development board
Note Items recognized by staff as typically outstanding at this point include a traffic
report and/or confirmation of the traffic concurrency approval from Palm Beach
County, drainage certification by a licensed engineer, and colored elevations of
the proposed project. This information is necessary for the project to proceed. If
you have submitted this information, please disregard this note
TRC MEMBERS
BOB BORDEN, ASSISTANT FIRE MARSHAL
KEVIN HALLAHAN, FORESTER/ENVIRONMENTALIST
LEE THOMPSON, POLICE DEPARTMENT
PETE MAZZELLA, UTILITIES DEPARTMENT
MICHAEL HAAG, BUILDING DIVISION
LARRY QUINN, PUBLIC WORKS DEPARTMENT
MARK LIPS
JOHN WILDNER, PARKS DIVISION
JACK CASLER, ACTING CITY ENGINEER
KEN HALL
MICHAEL RUMPF, PLANNING AND ZONING
JIM NGUYEN, PLANNING DIVISION
LUSIA GALAV, PLANNING DIVISION
FRANTZ LAFONTANT, ENGINEERING DIVISION
742-6602
742-6227
742-6105
742-6404
742-6352
742-6202
742-3208
742-6226
742-6280
742-6283
742-6260
742-6367
742-6262
742-6757
1 st REVIEW COMMENTS
ProJect name' QUANTUM BUSINESS CENTER (LOTS 32-38)
File number NWSP 00-003
Reference' 1st ReView. File # NWSP 00-001 with a January 1 L 2000 Planning and Zoning Department date
stamp marking
DEPARTMENTS INCLUDE REJECT
PUBLIC WORKS
Comments.
UTILITIES
Comments.
1 All utilities easements shall be shown on the rectified landscapIng
drawings so that utilities may determme which trees may interfere With
utilities. In general, palm trees will be the only tree speCIes allowed
withm utilIty easements. Canopy trees may be planted outside of the
easement so that roots and branches will not Impact those utilities withIn
the easement In the foreseeable future. LDR Sec 7.5-18 1 gives public
utilIties the authOrity to remove any trees that Interfere With utilIty
services, either In utility easements or public rights-or way
2 Dept. of Health permits may be reqUired for the water and sewer
systems serving thiS proJect. (Sec. 26-12).
3 Fire flow calculatIOns Will be reqUired demonstrating the City Code
reqUirement of 1500 g.p.m. as stated In LDR Chapter 6, Article IV,
SectIOn 16, or the reqUirement Imposed by insurance underwriters,
whichever is greater (see Section 26-16(a)). Please submit these
calculatIOns With your Health Department permit submittal.
4 Section 26-34(E) of the City Code requires that a capacity reservation
fee be paid for thiS proJect either upon my request for signature on the
Health Dept. applIcation forms or WithIn 30 days of site plan approval,
whichever occurs first. ThiS fee will be determined based upon final
meter Sizes, or expected demand.
5 Comp Plan policy 3C.3 4 reqUires the conservation of potable water
City water may not, therefore, be used for lITIgatIOn where other sources
are readily available
6 Water and sewer lines to be owned and operated by the City shall be
Included withm utility easements. The easements shall be dedicated via
separate instIllments to the City as stated In Sec. 26-33(a) of the Code
7 UtilIty Department will not reqUire surety for Installation of the water
and sewer utilities, on conditIOn that the systems be fully completed, and
given to the City before the first permanent meter is set. Note that
settIng of a permanent water meter IS a prerequisite to obtaIning the
certificate of occupancy
Page 2
Quantum Business Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
8 LDR Chap 6, Article IV, Sec. 16 reqUires that all pOInts on each
buildmg will be withIn 200 feet of an eXisting or proposed fire hydrant.
Please demonstrate that the plan meets thiS condition, by showing all
hydrants.
9 A buildIng permit for thiS proJect shall not be Issued until thIS office has
approved the plans for the water and/or sewer improvements reqUired to
serve the proJect. (Sec. 26-15)
10 The waste stream from all manufacturIng process must meet the City's
pretreatment requirements. A sampling point must be provided to allow
mOnItormg of any waste stream. (Sec 26-143,26-147)
FIRE
Comments.
11 A fire flow test IS reqUIred pnor to construction. LDR 6-16
12. Hydrants and access roads must be In place prior to above grade
construction. NFP A 1
POLICE
Comments.
13 At this time there are no roadway markings or traffic flow pattern
markIngs. I do foresee a couple of problem areas that will need to be
addressed before final approval.
ENGINEERING DIVISION
Comments.
14 On the Site Plan add a general note that all plans submitted for speCific
permits shall meet the City's code reqUirements at time of application.
These permits include, but are not limited to the following: site lighting,
pavmg, dramage, curbIng, landscapmg and lITIgatIOn. Permits required
from other permittIng agencies, such as FDOT, PBC, SFWMD, DERM,
L WDD, DEP and any others, shall be Included With the permit request.
15 Abandon that portIOn of the recorded 10 foot utility easement between
lots 32 & 33 to accommodate the new constructIOn.
16 Abandon that portion of the recorded 10 foot utility easement between
lot 38 and lots 36 & 37 to accommodate the new construction.
17 Provide a general note on sheet 4 of the paving and draInage plans that
the exfiltratIon system shall conform to City Standard DraWIng B-91 007
Page 3
Quantum Business Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
18 Any fill operation shall reqUire an excavatIOn/fill permit.
19 Show the draInage plan at the same scale as the SIte development plan.
[LDR Chapter 4, SectIOn 7.F ]
20 On the site and civil plans show the 5 foot concrete Sidewalk through
both driveways along Gateway Blvd. with a minImum thickness of 6"
[LDR Chapter 23, Article I1.P ]
21 On the site and civIl plans add a general note that all stnping, markIngs
and signage shall conform to City Standard Drawing B-91 007 and
reflect all stripIng, markIng and signage on both plans. [LDR Chapter 4,
SectIOn 7.B ]
22. Show proposed lightIng on both the landscape and Civil plans for
Inspection purposes and possible shading of parking lot areas. [LDR
Chapter 4, Section 7.B ]
23 On the slte and landscape plans Indicate the clear Sight tIlangle for the
two Gateway Boulevard dnveways and at the Quantum Boulevard
Intersection as speCified In FDOT Index 546
24 On the site and landscape plans Indicate the clear Sight triangles along
the four Quantum Blvd. driveways USIng the 35 foot legs of the triangle
as specified In LDR Chapter 75, Article II, Section 5.H.2.
25 On the landscape plans add a general note that the landscapIng Within
the safe Sight triangles shall have a clear, unobstructed cross-visibility
between 30 inches and 6 feet above the pavement. [LDR Chapter 7.5,
Article II, Section 5.H.]
26 On the site and CIVil plans show a five foot concrete Sidewalk along
Quantum Blvd. to the lImits of the site or obtaIn a waiver therefrom.
[LDR Chapter 22, Article I, SectIOn 5 & Chapter 6, Article IV, Section
lOt.]
27 Reduce the driveways along Quantum Blvd. from four to two per code
or obtain a variance therefrom. [LDR Chapter 23, Article I, SectIOn 3.B
& Article II.H.7 & LDR Chapter 2, SectIOn 7.H.3 ]
28 On the site and CIVil plans show the 5 foot handicap accessible paths
flush through the Sidewalks With a ramp up on either side per FlOrida
Accessibility Code (8 places).
29 The maximum driveway Width IS 32 feet. Obtain an approval for the
south driveway along Quantum Blvd. [LDR Chapter 23, Article II.H.l ]
Page 4
Quantum BusIness Center - Lots 32-38
FIle No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
30 If a sidewalk IS required along Quantum Blvd, then handicap assessible
paths should be shown through the landscaped areas going to the
sidewalk per FlOrida Accessibihty Code It IS recommended that there
be one for BuildIng #2 and two for BUildIng #3
31 On the ciVil plans provide cross-sectIOns of the following areas showmg
the elevatIonal differences between the finIshed site and the abuttmg
properties.
a. Lot 32 and the sand pine preserve to the north.
b Lots 32 & 33 along the water management Tract "J"
c Lots 34A & 34B along the unplatted parcel to the east
32. Remove the reference to a "tow away zone" on the handicap post sign.
See Standard Drawmg B-98001
33 On the pavmg and dramage plan Identify the 4 sheets on the locatIOn
map for reference purposes.
34 Specify a 12 mch minImum subgrade thickness on the "typical
pavement on Sheet 4 of 4 of the civIl drawmgs.
35 Correct the elevatIOn callouts of Buildings # 1 & #2
36 Clarify use of eXisting 48mch CMP at BuIlding #3
37 Show UnIty of Title for all 8 lots.
RECOMMENDATIONS
38 Locate the handicap post sign withm the landscape areas behmd the
sidewalk.
39 In heu of wheelstops and the asphalt between them and the 5 foot
sidewalks along the bUildIngs, construct 7 foot sidewalks Incorporatmg
the edge of curb as a continuous wheelstop ThiS reduces maintenance
and the potential trippIng hazards on Individual wheelstops.
40 On the paving and drainage plan specify that the 1112 mch of asphalt be
done m two hfts.
41 The mInimum average lighting withIn the parking areas may be one foot
candle subject to the specification in LDR Chapter 23, Article II.A.
BUILDING DIVISION
Comments.
42 Add to the buildmg(s) that are depicted on the drawing titled site plan a
Page 5
Quantum Busmess Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
labeled symbol that Identifies the location of the handicap accessible
entrance door to the each tenant space. Show and label the same door(s)
on the draWIng titled partial floor plan.
43 Add a labeled symbol to the draWIng that IS titled site plan. The symbol
shall represent and delineate the path of travel of the accessible route
that IS reqUired between the accessible parkIng spaces and the
accessible entrance doors to each tenant space Identify on the plan the
width of the accessible route. (Note The minImum width reqUired by
the code IS forty-four (44) Inches). Add text that would Indicate that the
symbol represents the accessible route and the route IS deSigned In
compliance with SectIOn 4.3 (Accessible Route) and 4 6 (Parking and
Passenger LoadIng Zones) of the FlOrida Accessibility Code for
BuildIng Construction. The symbol wIll represent the locatIOn of the
path of travel, not the locatIOn of the detectable warnIng or other
pavement markings that are reqUired to be installed along the path.
Please note that at time of permit review the apphcant shall provide
detailed documentation on the plans that wIll verify that the accessible
routes are In comphance with the regulatIOns specified in the FlOrida
Accessiblhty Code for BUlldmg Construction.
44 WithIn the site statistics found on the cover sheet and sheet A-I,
Identify the proposed finIsh floor elevation of the bUildIng (lowest floor
elevatIOn). Verify that the proposed elevatIOn complies With regulatIOns
of the code by addIng specifications and notes to the site data that
address the follOWIng Issues.
a) From the FIRM map, identify the title of the flood zone that the building is
located within. Where applicable, specify the base flood elevation. If
there is no base flood elevation, indicate that on the plans.
b) As the deSign professlOnal-of-record for the proJect, state that the
proposed floor elevation is above the highest 1 OO-year base flood
elevatIOn apphcable to the bUildIng Site, as determIned by the South
FlOrida Water Management District's surface water management
constructIOn development regulations. [Section 3107 1.2, Chapter
3 1 of the Boynton Beach amendments to the 1997 edition of the
Standard BUildIng Code]
c) Identify the floor elevatIOn that the deSign professional has
established for the bUildIng within the footprInt of the buildmg that
IS shown on the site plan, floor plan and Civil plan.
42 Add the follOWIng notes to the site plan that depicts the proposed
location ofthe site hghtIng poles/fixtures.
a) State that the locations of the site lighting poles are conceptual.
b) State that the site hghtIng wIll be evaluated for code compliance at
time of permit review
c) State that the proposed site lighting fixtures wi1lIlluminate the site
consistent With the specificatIOns Identified In the ParkIng Lot
Code
d) Identify the overall height dimenSIOn of the site lightIng pole and
Page 6
Quantum BusIness Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
fixture (Note' The overall height of the pole/fixture shall not
exceed the height limitatIOns of the ZonIng Code.)
Omit the pole lIghtIng photometric Information and draWIng. This
mformation is reqUired at time of permit submittal, not at site plan
review
43 On the drawmg titled site plan, IdentifY the symbol that represents the
property line
44 The submitted site plan and survey depict two of the three buildings
bemg constructed WithIn an easement. Amend the plans so that
structures do not encroach into an easement.
45 Indicate In the site statistics that each buddIng IS one story Indicate the
number of stOries Within the footprint of each building that is depicted
on the floor plan draWIngs
46 Below the drawings titled Partial Floor Plan, add text that would
Indicate that the draWIng IS conceptual.
47 At time of permIt submittal, provide a completed and executed City
UnIty of title form. The form shall describe all lots, parcels or tracts
combined as one lot. A copy of the deed With legal descriptIOns of each
property that IS beIng unified is reqUired to process the form. The
property owner that IS Identified on each deed shall match.
48 Withm the site statistics found on the cover sheet and withIn the site
statistics found on sheet A-I, IdentifY the uses proposed for each
bUlldmg.
49 Within the site statistics found on the cover sheet, a F-2 occupancy
classification was identified, however, the 1997 editIon of the Standard
BUilding Code Includmg the City's amendments to the Standard
BUildIng Code do not IdentifY an F-2 classificatIOn. Amend the plans
accordmgly
PARKS AND RECREATION
Comments. NONE
FORESTER/ENVIRONMENTALIST
Comments
49 The applicant must submit an environmental assessment of the site Flora
and Fauna. This should be completed as part of the site plan submittal
process.
50 The eXisting gopher tortOIses must be relocated off the site prior to the
Page 7
Quantum Business Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
site clearing and grubbIng permit Issuance.
51 The topographic survey of the site mdicates eXistIng trees which should
be Identified, and shown to be preserved in place, relocated or
removed/replaced on the site ThiS should be completed on the
landscape plan.
PLANNING AND ZONING
Comments.
52. For the second submittal, put plans together In one package All plan
sheets should be 24"x 36" size.
53 Provide site plan sheets at 1 "=30' scale to match landscape and
engIneenng plans.
54 Provide traffic control markIngs and slgnage for the vehicular use areas
(stop signs, directional signs etc). (Chapter 4 - Site Plan Review)
55 Applicant has proVided a colored elevatIOn drawmg with color chips.
Provide a mounted colored elevatIOn draWIng for the PlannIng and
Development Board meeting. (Chapter 4 - Site Plan Review)
56 The north and south elevation draWIngs are mislabeled. Please correct.
(Chapter 4, Site Plan Review)
57 Buildings 1 and 3 are located on eXistIng utility easements. Either move
the buildIngs or relocate these utlhty easements. (Chapter 4 - Site Plan
Review)
58 Indicate the locatIOn and dimenSIOn of landscape Sight triangles on the
landscape plan sheets. (Chapter 7.5, Article II, Landscape Code.)
59 Indicate the locatIOn of the fire hydrants and site lighting on the
landscape plan. There appears to be conflicts between landscapIng, site
lighting and fire hydrant placement. (Chapter 7.5, Article II, Landscape
Code)
60 The dnveway openIng located west of BUilding 2 has a dimenSIOn
greater than the maximum permitted 32 feet. Indicate the exact
dimenSIOn of thiS driveway on the site plan. Approval IS reqUired for thiS
driveway Width. (Chapter 23 - ParkIng Lots)
61 Label the dimension for the driveway throat for the maJor driveway
entrance on Quantum Blvd. (Chapter 23 - Parking Lots)
62 The drive aisle directly east of Building 1 encroaches Into the 40 foot
landscape buffer cutting It off at the corner ReVise the deSign of thiS
Page 8
Quantum Busmess Center - Lots 32-38
File No NWSP 00-003
DEPARTMENTS INCLUDE REJECT
area to prevent the encroachment. (Chapter 23 - ParkIng Lots.)
63 Indicate and label the right-of-way lIne for Gateway Blvd. and Quantum
Blvd. on the site plan. (Chapter 23 - ParkIng Lots.)
64 Provide a continuous concrete sidewalk through the driveway entrances
along Gateway Blvd. (NW 22nd Ave.). (Chapter 23 - Parking Lots.)
65 The site plan Indicates that SIX (6) driveways are proposed for thiS
project. No more than two (2) driveways are permitted per street
frontage. A variance wIll be reqUired to permit additIOnal driveways.
(Ch. 23, Art. II, H, 7)
66 Provide a Sidewalk along Quantum Blvd. (Ch. 6, Art. III, 11)
67 ProVide pedestrian/handicapped access from the maIn entrance of
BUildIngs 2 and 3 to a Sidewalk along Quantum Blvd. (Ch. 9,Sec 10, B).
68 The back of BUildIng 1 faces Quantum Blvd. With a fairly large
unobstructed Viewing area of the bay doors and dumpster enclosures
from the street, particularly at the large maJor entrance drive. Some
bermIng IS proVided but does not appear to create a sufficient buffer as
required by Ch. 9 - CommunIty DeSign Standards or the Quantum
DeSign ReView GUidelines. RedeSign of thiS area IS required.
69 Approval of thiS proJect IS required from the Quantum DeSign ReView
Committee (QDR).
70 A total of three (3) free standmg signs are proposed for the Site, one for
each of the three buildings. In additIOn, typical wall sign deSigns were
submitted as a separate 11 Inches X 17 inches color drawing labeled 2.0
The signs as presented are consistent with the approved Quantum
Master Sign Program. PrOVide a scaled detail draWIng of the typical wall
signs on sheet A-2 of the site plan package The permitted square
footage for wall signs IS 1.5 square feet for each one (1) foot of lInear
bUlldmg bay frontage
J:ISHRDATA\PLANNlNGISHARED\WP\PROJECTSIQUANTUM 2000ILOTS 32 3811ST REVIEW COMMENTS. DOC
TRANSMISSION VERIFICATION REPORT
TIME 02/03/2000 17 04
~~AME BOYNTON BEACH P & Z
FAX 5513755259
TEL 5513755250
DATE,TIME
FAX NO./NAME
DURATION
PAGE(S)
RESULT
MODE
02/03 15 58
%895559
00 05 00
10
Of<,
STANDARD
ECM
MEMORANDUM
UTILITIES DEPT NO 00 - 22
TO
Mike Rumpf, PlannIng Director \\ L
John A Guidry, Utilities Director ~ ~
January 31, 2000
fD) rUU -
~J ' FFB - I 200[;
I "
'1 Ii
.1/
'I I
FROM.
DATE
SUBJECT.
Quantum Business Center Lots 32-38
New Site Plan, 1 S[ Review
G AND
DEPT.
I
!
~-"
We offer the followmg comments on this project:
GENERAL COMMENTS
1) All utilities easements shall be shown on the rectified landscaping drawings so that we may
determine which trees may interfere with utilities In general, palm trees will be the only tree
species allowed within utility easements Canopy trees may be planted outside of the easement so
that roots and branches will not impact those utilities within the easement in the foreseeable future
LD R Sec 7 5-18 1 gives public utilities the authority to remove any trees that interfere With utility
services, either m utility easements or public rights-of-way
2) Dept. of Health permits may be required for the water and sewer systems servmg this project. (Sec
26-12)
3) Fire flow calculations will be required demonstrating the City Code requirement of 1500 g p.m, as
stated in LDR chap 6, Art. IV, Sec 16, or the requirement imposed by msurance underWriters,
whichever is greater (see Sec 26-16(a)) Please submit these calculations with your Health
Department permit submittal
4) Sec 26-34(E) of the City Code requires that a capacity reservation fee be paid for this project
either upon my request for signature on the Health Dept. application forms or Within 30 days of site
plan approval, whichever occurs first. This fee will be determined based upon final meter sizes, or
expected demand.
5) Comp Plan policy 3C 3 4 requires the conservation of potable water City water may not,
therefore, be used for irrigation where other sources are readily available
SPECIFIC CONDITIONS
1) Water and sewer lines to be owned and operated by the City shall be included within utility
easements The easements shall be dedicated via separate instrument to the City as stated in Sec
26-33(a) of the Code
2) This office will not require surety for installation of the water and sewer utilities, on condition that
the systems be fully completed, and given to the City before the first permanent meter is set. Note
that setting of a permanent water meter is a prerequisite to obtaining the certificate of occupancy
3) LDR chap 6, Article IV, Sec 16 requires that all points on each buildmg will be withm 200 feet of
an existing or proposed fire hydrant. Please demonstrate that the plan meets this condition, by
showing all hydrants
4) A building permit for this project shall not be issued until this office has approved the plans for the
water and/or sewer improvements required to serve the project. (Sec 26-15)
5) The waste stream from all manufacturing processes must meet the City's pretreatment
requirements A sampling point must be provided to allow monitoring of any waste stream. (Sec
26-143, 26-147)
Please refer any questions on this matter to Peter Mazzella (742-6404) of this office
JAG/PVM
XC Skip Milor
Peter Mazzella
File
DEPARTMENT OF ENGINEERING
MEMORANDUM
NO 00-016
FROM.
Michael W Rumpf, DIrector of Plannmg and Zomng
John Gmdry, Intenm Duector of Engmeenng ~
January 25, 2000
TO
DATE
RE
QUANTUM BUSINESS CENTER - LOTS 32-38 (NWSP 00-003)
NEW SITE PLAN 1 ST REVIEW COMMENTS
1 On the SIte Plan add a general note that all plans submItted for specIfic permIts shall meet the CIty'S
code requIrements at tIme of applIcatIOn. These permIts mclude, but are not lImIted to the followmg
sIte lIghtmg, pavmg, dramage, curbmg, landscapmg and IrngatIOn. PermIts reqUIred from other
permIttmg agencIes, such as FDOT, PBC, SFWMD, DERM, LWDD, DEP and any others, shall be
mcluded WIth the permIt request.
2 Abandon that portIOn of the recorded 10' utIlIty easement between lots 32 & 33 to accommodate the
new constructIOn.
3 Abandon that portIOn ofthe recorded 10' utIlIty easement between lot 38 and lots 36 & 37 to
accommodate the new constructIOn.
4 ProvIde a general note on sheet 4 of the pavmg and dramage plans that the ex filtratIOn system shall
conform to CIty Standard Drawmg B-91 007
5 Any fill operatIon shall reqUIre an excavatIOn/fill permIt.
6 Show the dramage plan at the same scale as the sIte development plan. [LDR Chapter 4, SectIOn
7.F]
7 On the sIte and CIVIl plans show the 5' concrete sIdewalk through both dnveways along Gateway
Blvd. WIth a mImmum thIckness of 6" [LDR Chapter 23, ArtIcle H.P ]
8 On the sIte and CIvIl plans add a general note that all stnpmg, markmgs and sIgnage shall conform to
CIty Standard Drawmg B-91 007 and reflect all stnpmg, markmg and slgnage on both plans [LDR
Chapter 4, SectIOn 7.B ]
9 Show proposed lIghtmg on both the landscape and CIvIl plans for mspectIOn purposes and possible
shadmg ofparkmg lot areas. [LDR Chapter 4, SectIOn 7.B ]
lOOn the sIte and landscape plans mdIcate the clear SIght tnangle for the two Gateway Boulevard
dnveways and at the Quantum Boulevard mtersectIOn as specIfied m FDOT Index 546
Engmeermg Department Memorandum No 00-016
Re Quantum Busmess Center - Lots 32-38, New SIte Plan 1 st ReVIew
January 25, 2000
Page Two
lIOn the site and landscape plans mdIcate the clear sIght tnangles along the four Quantum Blvd.
dnveways usmg the 35' legs ofthe tnangle as specIfied m LDR Chapter 75, ArtIcle II, SectIOn
5.H.2
12 On the landscape plans add a general note that the landscapmg wIthm the safe sIght tnangles shall
have a clear, unobstructed cross-vIsibIhty between 30" and 6' above the pavement. [LDR Chapter
7 5, ArtIcle II, SectIOn 5.H.]
13 On the SIte and CIvIl plans show a five foot concrete SIdewalk along Quantum Blvd. to the hmIts of
the SIte or obtam a waiver therefrom. [LDR Chapter 22, ArtIcle I, SectIOn 5 & Chapter 6, ArtIcle
IV, SectIOn lOt.]
14 Reduce the dnveways along Quantum Blvd. from four to two per code or obtam a variance
therefrom. [LDR Chapter 23, ArtIcle I, SectIOn 3.B & ArtIcle II.H.7 & LDR Chapter 2, SectIOn
7.H.3 ]
15 On the SIte and CIVIl plans show the 5' handIcap accessible paths flush through the SIdewalks WIth a
ramp up on eIther SIde per Flonda AccessibIhty Code (8 places)
16 The maXImum dnveway WIdth IS 32' Obtam an approval for the south dnveway along Quantum
Blvd. [LDR Chapter 23, ArtIcle II.H.l ]
17 If a SIdewalk IS reqmred along Quantum Blvd, then handIcap assessible paths should be shown
through the landscaped areas gomg to the SIdewalk per Flonda AccessibIhty Code. It IS
recommended that there be one for Bmldmg #2 and two for Bmldmg #3
18 On the CIVIl plans prOVIde cross-sectIOns of the followmg areas showmg the elevatIOnal dIfferences
between the fimshed SIte and the abuttmg properties
a. Lot 32 and the sand pme preserve to the north.
bLots 32 & 33 along the water management Tract "J"
cLots 34A & 34B along the unplatted parcel to the east.
19 Remove the reference to a "tow away zone" on the handIcap post SIgn. See Standard Drawmg B-
98001
20 On the pavmg and dramage plan IdentIfy the 4 sheets on the locatIOn map for reference purposes.
21 SpeCIfy a 12" mmImum subgrade thIckness on the "tYPIcal pavement on Sheet 4 of 4 of the CIvIl
drawmgs.
22. Correct the elevatIOn call outs of Bmldmgs # 1 & #2
23 Clanfy use of eXIstmg 48" CMP at Bmldmg #3
24 Show Umty of Title for all 8 lots.
Engmeenng Department Memorandum No 00-016
Re Quantum Busmess Center - Lots 32-38, New SIte Plan 1 st RevIew
January 25, 2000
Page Three
RecommendatIOns
1 Locate the handIcap post sIgn wIthm the landscape areas behmd the sIdewalk.
2 In heu of wheelstops and the asphalt between them and the 5' sIdewalks along the bUIldmgs,
construct 7' sIdewalks mcorporatmg the edge of curb as a contmuous wheelstop ThIS reduces
mamtenance and the potential tnppmg hazards on mdIvIdual wheelstops.
3 On the pavmg and dramage plan specIfy that the 11/2" of asphalt be done m two hfts
4 The mmImum average hghtmg wIthm the parkmg areas may be one foot candle subject to the
specificatIOn m LDR Chapter 23, Article II.A.
Ifthere are any questIOns please contact Jack Casler CIVIl Engmeer at 742-6282 or Ken Hall at 742-6283
JAG/ck
~A~ s ,CO
~ l/11;
C'\My Documents\Quantum Business Center Lots 32 38 New Site Plan 1st Review.doc
FIRE & LIFE SAFETY DIVISION
Memorandum No 2000-8
@'...
. :'~~- ~.
NFPA Life Safety Code 101, National Fire Code 1, all applicable National Fire
Protection Association codes, and the City Fire code shall be adhered to
FROM
DIC Gale ~~
Fire & Life Safety {)
fF~-' ~ @ r
\ in' r'- .
'1
,JAM 2 5 2000
TO
Mike Rumpf, Director
Planning & Zoning
~~
~D
DEPT.
DATE January 24, 2000
SUBJECT NWSP 00-003
LOTS 32-38
Quantam Business Center
A fire flow test is required prior to construction LOR 6-16
Hydrants and access roads must be in place prior to above grade construction NFPA 1
Project should go forward with the above comments
cc File
Parks Division Memorandum- TRC
To
Mike Rumpf, DIrector ofPlanmng and Zonmg
~~tt
From
Kevm J Hallahan, Forester / EnvIronmentalIst
Subject
Quantum Busmess Center
New SIte Plan -1st ReVIew
Date
January 24,2000
1 The applIcant must submIt an envIronmental assessment of the SIte Flora and Fauna. ThIS
should be completed as part of the SIte plan submIttal process
2 The eXIstmg gopher tortOIses must be relocated off the SIte pnor to the SIte clearIng and
grubbmg permIt Issuance
3 The topographIc survey of the SIte mdIcates eXIstmg trees WhIch should be Identified, and
shown to be preserved m place, relocated or removed / replaced on the SIte ThIS should be
completed on the landscape plan.
The project should contmue m the normal reVIew process.
KJh
File
CITY OF BOYNTON BEACH, FLORIDA
INTER-OFFICE MEMORANDUM
TO
MIchael Rumpf
DATE
SUBJECT
REFERENCES
ENCLOSURES
01/24/00
FILE
1 st RevIew Quantum Park Master Plan ModIficatIOn
FROM
Ofc M. Lane
Mr Rumphf, I've looked over the sIte plans for the Quantum Busmess Cente - Lots 32-3 At thIS tIme there
are no roadway markmgs or traffic flow pattern markmgs. I do forsee a couple 0 m areas that wIll need
to be addressed before final approval.
DEPARTMENT OF DEVELOPMENT
BUILDING DIVISION
MEMORANDUM NO 00-019
RE
Quantum Business Center (Lots 32-38) - New Si
1st review comments
Ian (NWSP 00-003)
TO'
Michael Rumpf, Plannmg and Zomng DIrector
FROM
Michael E Haag, Bmldmg Code Admlmstrator
DATE
January 21,2000
We have revIewed the plans for the above-referenced project. The applIcant must acknowledge
and address the below lIsted comments before the project IS presented to the Board for theIr
reVIew
Buildine Division (Permit & Site Specific Comments) - Michael E. Haag (561) 742-6352
I Add to the bm1dmg(s) that are depIcted on the drawmg tItled site plan a labeled symbol
that IdentIfies the locatIOn of the handIcap accessible entrance door to the each tenant
space. Show and label the same door(s) on the drawmg tItled partial floor plan.
2 Add a labeled symbol to the drawmg that IS tItled site plan. The symbol shall represent
and delmeate the path of travel of the accessible route that IS reqmred between the
accessible parkmg spaces and the accessible entrance doors to each tenant space. IdentIfy
on the plan the WIdth of the accessible route. (Note' The mmlmum WIdth reqmred by the
code IS forty-four (44) mches) Add text that would mdlcate that the symbol represents the
accessible route and the route IS deSIgned m complIance WIth SectIOn 4.3 (Accessible
Route) and 46 (Parkmg and Passenger Loadmg Zones) of the Flonda AccessibIlIty Code
for Bmldmg ConstructIOn. The symbol WIll represent the locatIOn of the path of travel, not
the locatIon of the detectable wammg or other pavement markmgs that are reqmred to be
mstalled along the path. Please note that at tIme of permIt reVIew the applIcant shall
provIde detaIled documentatIon on the plans that WIll venfy that the accessible routes are m
comphance WIth the regulatIOns specIfied m the Flonda AccessibIlIty Code for Bmldmg
ConstructIOn.
3
Withm the site statistics found on the cover sheet and sheet A-I, IdentIfy the proposed
fimsh floor elevatIon of the bmldmg (lowest floor elevatIOn) Venfy that the proposed
elevatIOn complIes WIth regulatIOns of the code by addmg specIficatIOns and notes to the
site data that address the followmg Issues
a) From the FIRM map, IdentIfy the tItle of the flood zone that the bmldmg IS located
wlthm. Where applIcable, specIfy the base flood elevatIon. If there IS no ~'lse flood
elevatIOn, mdIcate that on the plans. ;~~-G;
,;>'."-
"I n\,
. \
II
.}AN 2. A 20GO
i~.NI)
,q~1-,
BUIldmg DIVISIOn Memo No 00-019 to Michael Rumpf
RE Quantum Business Center (Lots 32-38) - New Site Plan _1st review comments
January 21,2000
Page Two
b) As the desIgn professIOnal-of-record for the project, state that the proposed floor
elevatIOn IS above the hIghest 1 OO-year base flood elevatIOn applIcable to the bUIldmg
SIte, as determmed by the South Flonda Water Management DIstnct's surface water
management construction development regulatIOns. [SectIOn 3107 1.2, Chapter 31 of
the Boynton Beach amendments to the 1997 edItion of the Standard BUIldmg Code]
c) Identify the floor elevatIOn that the deSIgn professIOnal has establIshed for the bUIldmg
wlthm the footpnnt of the bUIldmg that IS shown on the SIte plan, floor plan and CIVIl
plan.
4 Add the followmg notes to the SIte plan that depIcts the proposed locatIOn of the SIte
lIghtmg poles/fixtures
a) State that the locatIOns ofthe SIte lIghtmg poles are conceptual.
b) State that the SIte lIghtmg WIll be evaluated for code complIance at time of permIt
reVIew
c) State that the proposed SIte lIghtmg fixtures wIll Illummate the SIte conSIstent WIth the
speCIficatIOns Identified m the Parkmg Lot Code.
d) Identify the overall heIght dImensIOn ofthe SIte lIghtmg pole and fixture. (Note The
overall heIght of the pole/fixture shall not exceed the heIght lImItatIOns of the Zonmg
Code)
OmIt the pole lIghtmg photometnc mformatIOn and drawmg. ThIS mformatIOn IS reqUIred
at time of permIt submIttal, not at SIte plan reVIew
5 On the drawmg titled site plan, Identify the symbol that represents the property lIne
6 The submItted SIte plan and survey depIct two of the three bUIldmgs bemg constructed
wlthm an easement. Amend the plans so that structures do not encroach mto an easement.
7 IndIcate m the SIte statistics that each bUIldmg IS one story IndIcate the number of stones
wIthm the footpnnt of each bUIldmg that IS depIcted on the floor plan drawmgs.
8 Below the drawmgs titled PartIal Floor Plan, add text that would mdIcate that the drawmg
IS conceptual.
9 At time of permIt submIttal, prOVIde a completed and executed CIty umty of tItle form.
The form shall describe all lots, parcels or tracts combmed as one lot. A copy of the deed
WIth legal descnptIOns of each property that IS bemg umfied IS reqUIred to process the
form. The property owner that IS IdentIfied on each deed shall match.
10 Withm the site statistics found on the cover sheet and wlthm the site statistics found on
sheet A-I, Identify the uses proposed for each bUIldmg.
JAM 7- 4 2000
.
iei;\)
01
'~---
...
BUlldmg DIVISIOn Memo No 00-019 to Michael Rumpf
RE Quantum Business Center (Lots 32-38) - New Site Plan - 1 st review comments
January 21, 2000
Page Three
11 Withm the site statistics found on the cover sheet, a F-2 occupancy classIficatIOn was
IdentIfied, however, the 1997 edItIon of the Standard BUlldmg Code mcludmg the CIty'S
amendments to the Standard BUlldmg Code do not IdentIfy an F-2 claSSIficatIOn. Amend
the plans accordmgly
MEH.bg
nSHRDA TA\Development\Building-6870\Documents\TRC\NWSP 00-003 1st review Quantum Business Center (Lots 32 38).doc
LEISURE SERVICES PARKS DIVISION MEMORANDUM
TO
Michael W Rumpf
DIrector ofPlanmng & Zomng
FROM
. (~ ')1 ~'!-
John WJ1dner, Parks Director '0 L,t.. I
RE
QUANTUM BUSINESS CENTER-LOTS 32-38
DATE
January 18, 2000
I have no comments on the above-named project. ThIs project should contmue m the normal
review process,
JW\bal
-:\1
In: ~
i \11,
.' j
! l
f-~ @
II., JAN182000
\ ~ ~L
._~c....i
,\] AND
. DEPT.
t
_!
APPLICATION TRACKING LOG
PROJECT TITLE Quantum Business Center (Lots 32-38) FILE #: NWSP O('.^^~ OCJI
PROJECT LOCATION: QUANTUM PARK
TYPE OF APPLICATION: New Site Plan
PUBLIC NOTICE REQUIRED: (YIN) REVIEWER'S NAME
AGENT ADDRESS:
AGENT PHONE: FAX:
DATE REC'D: AMOUNT
RECEIPT NO
12 SETS OF PRE-ASSEMBLED PLANS SUBMITTED FOR REVIEW
2 OF 12 SETS SIGNED AND SEALED 0
SURVEY 0
LANDSCAPE PLAN 0
FLOOR PLAN 0
SITE PLAN WITH SITE DATA 0
APPLICATION/SUBMITTAL: DATE ACCEPTED:
DRAINAGE PLAN
ELEVATION VIEW DRAWINGS
COLORED ELEVATIONS RECEIVED
MATERIAL SAMPLES RECEIVED
PHOTOGRAPHS RECEIVED
o
o
o
o
o
DATE DENIED:
DATE OF LETTER TO APPLICANT IDENTIFYING SUBMISSION DEFICIENCIES:
1 ST REVIEW COMMENTS DUE:
1/25/00
1 ST REVIEW COMMENTS RECEIVED
MEMO# DATE
DATE OF LETTER SENT TO APPLICANT IDENTIFYING TRC REVIEW COMMENTS:
90-DAY CALENDAR DATE WHEN APPLICATION BECOMES NULL AND VOID:
DATE 12 COMPLETE (ASSEMBLED) SETS OF AMENDED PLANS SUBMITTED FOR 2ND REVIEW:
PRE-ASSEMBLED PLANS SUBMITTED FOR REVIEW:
AMENDED APPLICATION 0
2 OF12 SETS SIGNED AND SEALED 0
SURVEY 0
LANDSCAPE PLAN 0
FLOOR PLAN 0
SITE PLAN WITH SITE DATA 0
2ND REVIEW MEMO: DATE SENT
DRAINAGE PLAN
ELEVATION VIEW DRAWINGS
COLORED ELEVATIONS RECEIVED
MATERIAL SAMPLES RECEIVED
TRANSPARENCY RECEIVED
PHOTOGRAPHS RECEIVED
o
o
o
o
o
o
MEMO NO
RETURN DATE:
2nd REVIEW COMMENTS RECEIVED
PLANS MEMO# DATE PLANS MEMO# DATE
UTIL. 0 POLICE 0
PW 0 PLANNING 0
PARKS 0 BLDG/ENGR 0
fiRE 0 FORESTER 0
BOARD MEETING DATE:
LAND DEVELOPMENT SIGNS PLACED AT THE PROPERTY DATE SENT / SIGNS INSTALLED:
DATE:
BOARD:
CITY COMMISSION: DATE:
DEVELOPMENT ORDER RECEIVED FROM CITY CLERK: 0 DATE:
S:\FORMS\TRACKING LOG FORM - 3/98
DEVELOPMENT ORDER SENT TO APPLlCA~IT 0 DATE:
LJEPARTMENT OF DEVELOPMENT
MEMORANDUM NO PZ 99-010
FROM
TRC MEMBERS
Bob Borden, Assistant Fire Marshal
Kevin Hallahan, Forester/Environmentalist
Lee Thompson, Police Chief
Pete Mazzella, Utilities Department
Michael Haag, Building Division
Ken Hall, Engineering Division
Larry Quinn Public Works Department
John Wildner, Parks Division
Jack Casler, Acting City Engineer
,y~
Michael W Rumpf r3<!) ~
Director of Planning and Zoning
TO'
DATE
January 14, 2000
RE
SITE PLAN REVIEW PROCEDURES
1 ST Review - New Site Plan
Project - Quantum Business Center - Lots 32-38
Location - Quantum Park
Agent - Winston Lee & Associates, Inc
File No NWSP 00-003
Find attached for your review the plans and exhibits for the above-referenced project. Please review the
plans and exhibits and transmit formal written comments or e-mail to JoAnn Alea and I no later
than January 25. 20005:00 P.M. on When preparing your comments, please separate them into
two categories, code deficiencies with code sections referenced and recommendations that you
believe will enhance the project.
Adhering to the following review guidelines will promote a comprehensive review and enable the
applicant to efficiently obtain Technical Review Committee approval
1 Use the review standards specified in Part IV, Land Development Regulations Site Plan Review
and the applicable code sections of the Code of Ordinances to review and formulate comments
2. The documents submitted for the project were determined to be substantially complete with the
exception of traffic data, however, if the data provided to meet the submittal requirements is
insufficient to properly evaluate and process the project based on the review standards or the
documents show code deficiencies, additional data and/or corrections should be requested by
the reviewer by contacting Lusia Galav, or myself
3 Each comment shall reference the section of the code that is incorrectly depicted on the
documents
Page 2
4 Technical Review Committee member(s) shall identify in their comments when the plans depict or
when the location and installation of their departmental required improvements may conflict with
other departmental improvements
5 When a TRC Member finds a code deficiency that is outside of his/her review responsibility the
comment and the specific code section may be included in their review comments with the name
of the appropriate TRC Member that is responsible for the review specified
6 If a TRC member finds the plans acceptable, he/she shall forward a memorandum, within the time
frame stated above, to me The memorandum shall state that the plans are approved and that
they do not have any comments on the plans submitted for review and that they recommend the
project be forwarded through the approval process
All comments shall be typed, addressed and transmitted or e-mailed to JoAnn Alea and I for distribution to
the applicant. Please include the name and phone number of the reviewer on this memorandum or e-
mail Scott Barber will be the Planning and Zoning staff member coordinating the review of the project.
First review comments will be transmitted to the applicant along with a list of Technical Review Committee
(TRC) members
MWR.jma
Attachment
XC Steve Gale, Fire Marshal
Marshall Gage, Police Department
John Guidry, Utilities Director
Don Johnson, Building Division
Larry Roberts, Public Works Director
Central File
J:\SHRDATAIPLANNINGISHARED\WPIPROJECTSIQUANTUM 2000lHAMPTON INN MSPM 00-O0111STREVIEW.PLANSDOC
....
...
W 'i '
~ i "".......~ I ~ \ 3
...~oOt \ i \\\\\\\\\~\~
z..:::-=*'
, .n i a.
... ~ ~ ~.,~~~=~~:~; ....
.., a- t \ :ij;1i~;;.;Il.' ~(Il
\~ l ri ~ .~
\ a.O~
z~ I gza.
w.....
0.... 1i \ i!\\ nn ~~~
~c::.' O~~
0 'i -e\ w~a
:;lOll 5 ~i\ \'-t \ ~ ~w::>
g - -'i!'il- .. tfI~O
0 \ \\3\\\t\ !tn\ ·
.... ~ ffi
,.. -::, b---~ in '!! ~
~
.0 a- o.\!:;o%at
~ ~
5 ::l
Th \
tfI
~
~
~
!
-
~---
~
~
j~
'<"~~\\1
~\\
\
\
\
\
\
\
\
\
\
\
\
- - - ~\:
_ m
~
!"~~ - - -- -
m
---
i! \ '
lS- 'i it \ tt '
i \ \ \~ \ \11 ~
tll 'in -tt ~
\\ \.~\tl\~~\ \
~ \ !\~~~\t\\i \
il\ las .~~(: 1
, ii:~\\~iill\!
t. l\\ l!~'l\' \
"\ ,,\ -~tl\ i \
~ \1 \\U\t\\\\ :
l
\
~
"
II
:a
~
t~
---~--------- ~~-