REVIEW COMMENTS
Galav, Lusia
From
Sent:
To
Subject:
Hallahan, Kevin
Tuesday August 07 2001 1 19 PM
Galav Lusia
RE Boynton Beach Medical Pavilion (NWSP 01-004)
Lusia,
The applicant had addressed my one comment after the first review Thanks Kevin
-Original Message-----
From: Galav Lusia
Sent: Tuesday August 07 2001 12:55 PM
To: Hallahan, Kevin
Subject: Boynton Beach Medical Pavilion (NWSP 01-004)
Kevin
You had one comment for ist review on the above referenced site plan Does it still apply after 2nd review (7/31)? Let
me know Thanks
Lusia
1
APPLICATION TRACKING LOG
PROJECT TITLE East Boynton Medical Arts Pavilion I FILE #. NWSP 01-004
PROJECT LOCATION 2800 Seacrest Boulevard
TYPE OF APPLICATION Zonin2 Code Variance
PUBLIC NOTICE REQillRED. REVIEWER'S NAME
AGENT Chris Kerr, Kilday & Associates ADDRESS. 1551 Forum PI, Ste 100A, West Palm Beach, FI
33401
AGENT PHONE 561-689-5522 FAX. ~ (5 (P I) 0 ~9 ' '2- 51 Z-
I
DATE REC'D. AMOUNT
RECEIPT NO..
12 SETS OF PRE-ASSEMBLED PLANS SUBMITTED FOR REVIEW YES
2 OF 12 SETS SIGNED AND SEALED D DRAINAGE PLAN D
SURVEY D ELEVATION VIEW DRAWINGS D
LANDSCAPE PLAN D COLORED ELEVATIONS RECEIVED D
FLOOR PLAN D MATERIAL SAMPLES RECEIVED D
SITE PLAN WITH SITE DATA D PHOTOGRAPHS RECEIVED D
APPLICATION/SUBMITTAL. DATE A~' DATE DENIED' 0 /Zo /0'
DATE OF LETTER TO APPLICANT IDENTIFYING SUBMISSION DEFICIENCIES.
DATE OF SUBMITTAL ACCEPTANCE LETTER.
INITIAL 1ST REVIEW MEMO SENT 7/ t ~(n(
MEMO NO..
RETURN DATE
1 ST REVIEW COMMENTS RECEIVED
PLANS MEMO # DATE DEPARTMENTS PLANS MEMO # DATE
UTILITIES G Qt - 1& / 7 1')/01 POLICE D/ N/A
PUBLIC WORKS [5" PLANNING -'" N/A
PARKS v 01- 07 7/2-101 BLDG. '-' ----- o 1- I~ 7/&/01
FIRE ./ u/A 7/ [, /0 I FORESTER /' N/A 7/3/D)
ENGINEER , 01- 1 D 1 "1 Jr'/D J
DATE OF LETTER SENT TO APPLICANT IbENTIFYING TRC REVIEW COMMENTS.
TECHNICAL REVIEW COMMITTEE DATE
90-DA Y CALENDAR DATE WHEN APPLICATION BECOMES NULL AND vom'
DATE 12 COMPLETE (ASSEMBLED) SETS OF AMENDED PLANS SUBMITTED FOR 2ND REVIEW
AMENDED APPLICATION
2 OF12 SETS SIGNED AND SEALED
SURVEY
LANDSCAPE PLAN
FLOOR PLAN
SITE PLAN WITH SITE DATA
D
D
D
D
D
D
DRAINAGE PLAN
ELEVATION VIEW DRAWINGS
COLORED ELEVATIONS RECEIVED
MATERIAL SAMPLES RECEIVED
TRANSPARENCY RECEIVED
PHOTOGRAPHS RECEIVED
D
D
D
D
D
D
PLANNING AND DEVELOPMENT BOARD MEETING DATE.
CITY COMMISSION DATE:
J'\SHRDATA\Planning\SHARED\WP\PROJECTS \East Boynton Medical Arts Pavilion Tracking log form.doc
Tucker, Patricia
From
Sent:
To
Cc
Subject:
Rumpf Michael
Wednesday July 11 2001 1249 PM
Tucker Patricia
Galav Lusia
FW Plan Reviews
Jeffs no comments response MR
-Original Message-n--
From: Livergood, Jeffrey
Sent: Wednesday, July 11, 2001 8 24 AM
To: Rumpf Michael
Subject: Plan Reviews
Mike
I have been out of town and did not review a number of plans sent my way I have looked at them briefly and find no traffic
related comments I have other comments but these are not related to traffic Others will address
Plans reviewed are as follows
Palm Walk
Elementary School 981
East Boynton Medical Arts Pavilion
Applebees/BJ's
Jeff
Jeffrey R. Livergood, P E.
Director of Public Works
City of Boynton Beach
1
DEPARTMENT OF UTILITIES
MEMORANDUM
NO 01-161
TO
Michael W Rumpf, DIrector of Planmng and Zomng
John A. Gwdry, Utilil1es DIrector \V
H. DaVId Kelley, Jr , PE/PSM, UtIhty EngIneer~
THRU
FROM.
DATE
July 5, 2001
RE
EAST BOYNTON MEDICAL ARTS PAVILION
NWSP 01-004 - 1 st REVIEW
We offer the followmg comments on the above noted proJect:
GENERAL COMMENTS
1) All utIhty easements (and/or access) shall be shown on the rectIfied SIte plan and landscapIng
drawmgs so that we may determIne whIch trees may Interfere wIth utlhtIes. In general, palm trees
wIll be the only tree speCIes allowed wIthIn utIhty easements. Canopy trees may be planted
outsIde of the easement so that roots and branches wIll not Impact those utIlIties WIthIn the
easement In the foreseeable future. LDR Sec 7.5-18 1 gIve pubhc utIlIties the authonty to remove
any trees that Interfere wIth utIhty servIces, eIther In utlhty easements or pubhc nghts-of-way
2) Palm Beach County Health Department permIts may be reqUIred for the water and sewer systems
serving thIS project (CODE Sec. 26-12)
3) FIre flow calculatIOns WIll be reqUIred demonstratIng the CIty Code reqUIrement of 1,500 g.p.m. at
stated m LDR Chap. 6, Art. IV, Sec 16, or the reqUIrement Imposed by Insurance underwrIters,
whIchever IS greater (see CODE Sec 26-16(a)) [If the proposed buildIng IS to have a spnnkler
system, thIS reqUIrement may be deleted.]
4) CODE Sec. 26-34(E) reqUIres that a capacIty reservatIOn fee be paId for thIS project eIther upon
the request for the Department's SIgnature on the Health Department apphcation forms or WIthIn
30 days of SIte plan approval, whIchever occurs first. This fee wIll be determIned based upon final
meter SIze, or expected demand.
5) ComprehensIve Plan Pohcy 3 C.3 4 reqUIres the conservatIOn of potable water CIty water may
not, therefore, be used for lITIgatIOn where other sources are readIly available
6) ProvIde an engIneer's wntten certIficatIOn that draInage wIll conform to all rules of the City and
the South Flonda Water Management Dlstnct (SFWMD) (per LDR Chap 4, Sec 7F)
UtilIty Department Memorandum No 01-161
Re East Boynton MedIcal Arts PavIlIon
July 5,2001
Page Two
SPECIFIC CONDITIONS
1 LDR Chap 6, Art. IV, Sec. 16 reqUires that all pomts on each buildmg wIll be wIthin 200 feet of
an eXIstmg or proposed fire hydrant. Please demonstrate that the plan meets thIS condItion, by
shOWing all hydrants. [Refer to preVIOUS comment noted above.]
2. Appropnate backflow preventers Will be reqUired on the domestic water servIce to the bUIldmg,
and the fire spnnkler lIne If there IS one, m accordance WIth CODE Sec 26-207
3 A bUIldmg permIt for thIS project shall not be Issued untIl tills Department has approved the plans
for the water and/or sewer Improvements reqUired to servIce thIS project, m accordance WIth
CODE Sec. 26-15
4 Any waste stream from the medIcal dIscard process must meet the CIty'S pretreatment
reqUirements. A samplmg pomt must be proVIded to allow momtormg of thIS waste stream (refer
to CODE Sec. 26-143, Sec 26-147)
5 UtIlIty construction detaIls as shown on CIvIl Engmeenng (CE) sheets 7 thru 9 of 9 wIll not be
revIewed for constructIOn acceptabIlIty at thIS time. All utilIty constructIon detaIls shall be m
accordance WIth the UtIlIties Department's "Utilities Engineering Design Handbook and
Construction Standards" manual, they wIll be reviewed at the time of constructIOn permIt
applIcatIOn.
6 LikeWIse, pavmg, dramage and SIte detaIls as shown on CE sheet 4 of 9 wIll be revIewed for
constructabIlIty at the time of constructIOn permIt applIcatIOn.
HDK/ck
Xc Georganne Barden, UtilIty Dept.
FIle
C-\My Documents\East Boynton Medical Arts Pavilion, Utility 1st Review.doc
DEPARTMENT OF ENGINEERING
MEMORANDUM
NO 01-109
RE
East Boynton Medical Arts Pavilion
New Site Plan Review Comments - 1st Review
File No. NWSP 01-004
~
'm ~ ~ ~ [i rl~rn
I : Ii!
: "~L~L - 62001 .J :~) l
i
TO
Michael W Rumpf, Duector of Plannmg and Zomng
FROM.
Launnda Logan, P.E., Civil Engmeer
DATE
July 5, 2001
I have reviewed the above referenced SIte Plans, forwarded to me on June 27, 2001, against the SIte Plan
RevIew reqUIrements outlmed m the CIty of Boynton Beach Code of Ordmances. Followmg are my
comments wIth the appropnate Code and Land Development Regulations (LDR) referenced.
Code ReqUIrements
1 On the SIte Plan, add a general note that all plans submItted for specIfic permIts shall meet the CIty'S
Code reqUIrements at tIme of applIcatlon. These permIts include, but are lImited to, the followmg.
paving, dramage, curbmg, sIte lIghting, landscaping and ImgatIOn. Permits required from other
permittmg agencIes such as Flonda Department of TransportatIOn (FDOT), South Flonda Water
Management DIstnct (SFWMD), Lake Worth Dramage DIstnct (LWDD), Flonda Department of
EnvIronmental ProtectIOn (FDEP), Palm Beach County Health Department (PBCHD), Palm Beach
County Engineenng Department (PBCED), Palm Beach County Department of Envuonmental
Resource Management (PBCDERM) and any others, shall be mcluded With the permIt request.
2. Show zomng and land use on SIte CharactenstIcs Map (Survey) (LDR, Chapter 4, SectIOn 7.A.)
3 Show all eXIstmg utIlItles on SIte Charactenstlcs Map (Survey) and SIte Development plan (LDR,
Chapter 4, SectIOn A.3)
4 ProvIde detaIl for dumpster enclosure area (CIty of Boynton Beach Standard DraWing A-88007)
5 ProvIde an engmeer's certIficatIOn on the Dramage Plan as specIfied m LDR, Chapter 4, SectIOn
7.F.2
6 Catch basm and manhole covers shall be bIcycle proof (LDR, Chapter 6, ArtIcle IV, SectIon 5.A.2.f)
7 Determme ownershIp and maintenance responsibility for storm sewer system. Show that permIttmg IS
bemg pursued and that all permIt reqUIrements wIll be adhered to durmg constructIOn.
8 SIdewalks shall be constructed concurrent with buildmg constructIOn and shall be 4 feet Wide along
local streets, and 5 feet WIde along streets of hIgher classIficatIOn (LDR, Chapter 6, ArtIcle IV,
SectIon 10 T., and Chapter 22, ArtIcle I, SectIOn 5)
Department of Engmeenng N1.._.10randum No 01-109
Re' East Boynton Plan ReVIew Comments - 1 st RevIew
July 5, 2001
Page Two
9 SIdewalks adjacent to parkmg lots shall be contmuous through all dnveways and shall be 6 m. thIck
WIthm dnveways (LDR, Chapter 23, ArtIcle II, SectIOn P)
10 Add a note to the Landscape Plan that wIthm the SIght tnangles there shall be an unobstructed cross-
vIsibIhty as a level between 2.5' and 6' above the pavement (LDR, Chapter 7.5, ArtIcle II, SectIOn
5.H.)
lIOn the SIte and CIvIl plans, show and IdentIfy all necessary traffic control deVIces such as stop bars,
stop SIgns, double yellow lane separators stnpmg, dIrectIOnal arrows and "Do Not Enter" sIgnage, etc
Dehneate and stnpe the "Loadmg Area" (where applicable), mclude a pavement message m yellow
mdlcatmg "No Parkmg - Loadmg Zone" See CIty Standard DraWings B-98001 and B-90013 for
stnpmg detaIls.
The fire lane sIgnage and markmgs shall conform to LDR Chapter 23, ArtIcle II, SectIOns B & M.
The 3-foot hIgh "FIre Lane" words shall be placed along both lanes and staggered. Please note gross
bmldmg area IS greater than 15,000 SF
RecommendatIons/CorrectIons
1 IndIcate whIch edItIon of the FDOT Standard SpecIficatIOns for Road & Bndge and Standard Index IS
to be used -the 2000 SpecIficatIOns are recommended since they have both Enghsh and Metric umts.
2 General Notes 1 and 2 conflIct WIth each other General Note 2 conflIcts With Pavmg & Dramage
Note 1-5
3 Reference FDOT Standard Index 546 for the SIght tnangles along all collector and artenal roadways.
4 Sheet 4 of 9, TypIcal Pavement SectIOn, calls for Type S-III AsphaltIc Concrete With Tack Coat.
Pnme should be specIfied.
5 At both sets of HandIcap Stalls (on SIte and CIvIl plans) show the SIdewalk at the same elevatIOn as the
five foot accessible paths WIth 1 12 ramps up m both directIOns (FL Accessibihty Code 46.3) ThIS
needs to be reflected m the detmls on Sheet 5 of9 (CIvIl Plans)
6 Locate stop bars (Sheet 3 of9 - CIvIl Plans) behmd the accessible route from the public SIdewalk.
7 Delete reference to "Tow-Away Zone" on the TypIcal HandIcapped Sign detail (Sheet 5 of 9 - CIvil
Plans)
8 Delete "Do Not Enter" SIgn detail If not used (Sheet 5 of9 - CIVIl Plans)
9 SpeClry and dctilll a 5' x 5' hanmcap pavement symbol (Clry SmndMd Dml~L;~ : ; J rn 1\
I
Department of Engmeenng M..._.lOrandum No 01-109
Re East Boynton Plan RevIew Comments - 1 st Review
July 5, 2001
Page Three
10 Specify storm sewer diameters, mlet types, etc. on dramage plan. IndIcate grate, nm and mvert
elevatIOns for all structures. IndIcate grade of storm sewer segments. IndIcate matenal specIficatIOns
for storm sewer ProvIde details for eXIstmg basm top to be modIfied on Seacrest Boulevard.
LUck
I ill I ~ J:_~ ;_~;I ~J rn i
I "
r
C:\My Documents\East Boynton Medical Arts Pavilion, Engr 1st Review.doc
CITY OF BOYNTON BEACH
DEVELOPMENT DEPARTMENT
100 East Boynton Beach Blvd
POBox 310
Boynton Beach, Florida 33425-0310
PLAN REVIEW COMMENTS
For review of"
NWSP 01-004 1st review-fire
Project Name or Address
East Boynton Medical Arts Pavilion
2800 S. Seacrest Blvd.
Reviewed by'
f~
Rodger Kemmer. Fire Plans Examiner/Fire
Inspector
Department:
Fire and Life Safety
Trade
Fire Department
Phone
(561) 742-6753
Comments to
Elizabeth Cabrera by email on 7/6//01
CODE REQUIREMENTS
Compliance with NFPA 101, Life Safety Code, NFPA 1, Fire Prevention Code,
and city ordinances is required
1 Provide 6-inch address numbers posted at roadway per NFPA 1, Fire
Prevention Code, section 3-7 1, and city ordinance
2 Provide fire lane in accordance with NFPA 1, Fire Prevention Code,
section 3-5 2 Note minimum 20-ft width, live load capability for fire
apparatus, and turn around requirement. (See also City Ord section 9-21)
3 City water flow requirements
a) Maximum distance allowed between hydrants is three hundred
feet(300')
b) No part of the structure may be more than two hundred feet (200')
from a hydrant.
c) Six-inch (6") minimum main size is required and must be shown
d) 1,500 GPM fire flow is required
e) A fire flow test is required prior to construction
f) Five-foot (5') clear zone required around a hydrant.
4 Roads and hydrants must be in place prior to any construction above
grade (NFPA 241 (1966) Standard for Safeguarding Construction,
Alteration, and Demolition Operations, sections 5-4 3 and 6-7.2 2.
5 Fire sprinkler system is required per city ordinance 098-45, Article I,
Section 9-6, Section 7-1 1.A
6 Provide shop drawings, hydraulic calculations, and cutsheets for the
proposed sprinkler system indicating compliance with NFPA 13, Standard
for the Installation of Sprinkler Systems
7 Provide portable fire extinguishers per NFPA 10, Standard for Portable
Fire Extinguishers
8 Provide exit signs with battery back-up per NFPA 101, Life Safety Code,
section 5-8
9 Provide emergency lighting in accordance with NFPA 101 (1997), Life
Safety Code section 5-9
10 Provide shop drawings, cutsheets, and battery calculations for the
proposed fire alarm system, indicating compliance with NFPA 72, National
Fire Alarm Code
11 Provide a Knox Box for emergency response personnel per section 9-15
of City Ord
cc S Hale, Fire Marshal
B Borden, Deputy Fire Marshal
TO
MIchael Rumpf, Planmng & Zonmg Duector
ill ~ @ D ~ rr r;'-~
~ I~ \' S '
D 'J is J : :'. i r'.
r----.----l! j! i.
I ... I'
I I'" i
I JUL - 9 ?u I 1:11
Pl~NNING AND
ZONING DEPT
DEPARTMENT OF DEVELOPMENT
BUILDING DIVISION
MEMORANDUM NO. 01-150
FROM
TImothy K. Large, BUIldmg Code Admlmstr 0
DATE
July 6, 2001
RE
East Boynton Medical Arts Pavilion (NWSP 01-004) - 1 st review comments
We have revIewed the subject plans and recommend that the request be forwarded for Board
reVIew WIth the understandmg that all remammg comments WIll be shown m complIance on the
workmg drawmgs submItted for permIts.
Buildine Division (Site Specific and Permit Comments) - Timothy K. Lar~e (561) 742-6352
I Add to the bUIldmg that IS depIcted on the drawmg titled sIte plan a labeled symbol that
Identifies the locatIOn of the handIcap accessible entrance doors to the bUIldmg. Flonda
AccessibIlIty Code for BUIldmg ConstructIOn, SectIon 4 1.2, 4.3
2 On the floor plan drawmg, add a labeled symbol that Identifies the locatIOn of the handIcap
accessible entrance doors to the bUIldmg. The locatIOn of the doors shall match the
locatIOn of the accessible entrance doors that are depIcted on the sIte plan drawmg. Flonda
AccessibIlIty Code for BUIldmg ConstructIOn, SectIOn 4 1.2, 4 3
3 Add a labeled symbol to the sIte plan drawmg that Identifies the locatIOn ofthe handIcap
accessible parkmg spaces. The quantity of the spaces shall be consIstent WIth the
regulatIOns specIfied m the Flonda AccessibIlIty Code for BUIldmg ConstructIOn. The
accessible parkmg spaces that serve a use shall be located on the shortest safely accessible
route of travel from adjacent parkmg to an accessible entrance. The Flonda AccessibIlIty
Code for BUIldmg ConstructIOn states that bUIldmgs wIth multiple accessible entrances
shall have accessible parkmg spaces dIspersed and located closest to the accessible
entrance. Flonda AccessibIlIty Code for BUIldmg ConstructIOn, SectIOn 4 1.2 (5), 4.3, 4 6
Parkmg for medIcal facIlItIes shall comply wIth Flonda AccessibIlIty Code for BUIldmg
ConstructIOn, SectIOn 4 1.2 (5) (d) (i) (Ii)
4 Add a labeled symbol to the SIte plan drawmg that represents and delmeates the path of
travel for the accessible route that IS reqUIred between the accessible parkmg spaces and
the accessible entrance doors to the bUIldmg. The symbol shall start at the accessible
parkmg spaces and termmate at the accessible entrance doors to the bUIldmg. The symbol
shall represent the locatIOn of the path of travel, not the locatIOn of the detectable warmng
or other pavement markmgs that are reqUIred to be mstalled along the path. The locatIon
of the accessible path shall not compel the user to travel m a dnve/lane area that IS located
behmd parked vehIcles. IdentIfy on the plan the WIdth of the accessible route. (Note The
mmlmum WIdth reqUIred by the code IS forty-four (44) mches) Add text to the drawmg
that would mdlcate that the symbol represents the accessible route and the route IS
deSIgned m complIance WIth SectIOn 4.3 (Accessible Route) and 4 6 (Parkmg and
Memo to Michael Rumpf
July 6, 2001
RE East Boynton MedIcal Arts PavIlIon (NWSP 01-004) - 1 st reVIew comments
Page 2
Passenger Loadmg Zones) of the Flonda AccessibIlIty Code for BUIldmg ConstructIon.
Please note that at tIme of permIt reVIew, the applIcant shall provIde detaIled
documentatIOn on the plans that wIll venfy that the accessible route IS m complIance wIth
the regulatIOns specIfied m the Flonda AccessibIlIty Code for BUIldmg ConstructIOn. ThIS
documentatIOn shall mclude, but not be lImIted to, provldmg fimsh grade elevatIOns along
the path of travel.
5 IdentIfy wlthm the sIte data the fimsh floor elevatIOn (lowest floor elevatIon) that IS
proposed for the bUIldmg. Venfy that the proposed elevatIOn IS m complIance wIth
regulatIOns of the code by addmg specIficatIOns to the sIte data that address the followmg
Issues [SectIOn 3107 1.2, Chapter 31 of the Boynton Beach amendments to the 1997
edItIon of the Standard BUIldmg Code]
a) The deSIgn professIOnal-of-record for the project shall add the followmg text to the sIte
data. "The proposed fimsh floor elevatIOn _ _ NGVD IS above the hIghest 100-
year base flood elevatIOn applIcable to the bUIldmg sIte, as determmed by the South
Flonda Water Management Dlstnct's surface water management constructIOn
development regulatIOns."
b) IdentIfy the floor elevatIOn that the desIgn professIOnal has establIshed for the bUIldmg
wlthm the footpnnt of the bUIldmg that IS shown on the drawmgs tItled SIte plan, floor
plan and pavmg/ dramage (CIVIl plans)
6 On the drawmg tItled SIte plan, IdentIfy and label the symbol that represents the property
lme.
7 As reqUIred by Chapter 4, sectIOn 7 of the Land Development RegulatIOns, submIt a floor
plan drawmg. The bUIldmg plans are not bemg revIewed for complIance wIth the
applIcable bUIldmg codes. Therefore, add the words "Floor plan layout IS conceptual"
below the drawmg tItled Floor Plan found on sheet(s) _ However, add to the floor
plan drawmg a labeled symbol that IdentIfies the locatIOn of the handIcap accessible
entrance doors to the bUIldmg. The locatIOn of the doors shall match the locatIOn of the
accessible entrance doors that are depIcted on the SIte plan drawmg.
8 Place a note on the elevatIOn VIew drawmgs mdlcatmg that the wall openmgs and wall
constructIOn comply wIth Table 600 of the 1997 edItIOn of the Standard BUIldmg Code.
9 On all floor plan drawmgs, mdlcate wlthm the footpnnt of the bUIldmg the number of
stones that are m the bUIldmg mcludmg, where applIcable, mezzanmes.
10 IndIcate on the floor plan drawmg wlthm the footpnnt of the bUIldmg the pnmary use of
the structure/facIlIty If the bUIldmg IS an expanSIOn of an eXlstmg bUIldmg, mdlcate wIth
the footpnnt of the new and eXlstmg bUIldmg the pnmary use of the structure/facIlIty
11 IdentIfy on the SIte plan drawmg the actual dIstance that the bUIldmg IS set back from the
north, east, south and west property lmes Please note that overhangs, covered walkways,
canopIes, awnmgs or other appurtenances that are attached to the bUIldmg shall be
conSIdered when IdentIfymg bUIldmg setbacks. Therefore, IdentIfy the WIdth of the
Memo to Michael Rumpf
July 6, 2001
RE East Boynton MedIcal Arts PavIlIon (NWSP 01-004) - 1 st reVIew comments
Page 3
proposed overhangs, covered walkways, canopIes, awmngs, and/or other roofed areas that
extend out beyond the mam walls of the bUIldmg. The bUIldmg setbacks shall comply wIth
setback regulatIOns specIfied m the Zomng Code.
12 To venfy that the proposed bUIldmg IS m complIance wIth the applIcable bUIldmg
setbacks, show and dImenSIOn on the sIte plan the WIdth of the bUIldmg overhang. Also,
IdentIfy the SIze or WIdth of the covered walkways, awnmgs, canopIes and/or other roofed
areas that extend out beyond the mam walls of the bUIldmg.
13 At tIme ofperrmt reVIew, proVIde a completed and executed CIty umty of tItle form. The
form shall describe all lots, parcels or tracts combmed as one lot. A copy of the recorded
deed wIth legal descnptIons of each property that IS bemg umfied IS reqUIred to be
submItted to process the form. The property owner that IS IdentIfied on each deed shall
match.
14 At tIme of permIt reVIew, submIt SIgned and sealed workmg drawmgs of the proposed
constructIOn.
15 Add to the drawmg the calculatIOns that were used to IdentIfy the mImmum number of
reqUIred handIcap accessible parkmg spaces. Also, state the code sectIon that IS applIcable
to the computatIOns.
16 At tIme of permIt reVIew, submIt for reVIew an addressmg plan for the proJect.
17 Add to all plan VIew drawmgs ofthe sIte a labeled symbol that represents the locatIOn and
penmeter of the lImIts of constructIOn proposed WIth the subject request.
rs
\\CH\MAIN\SHRDA TA\Development\BuiIding Div\Documents\TRC\NWSP 01-004 East Boynton Medical Arts Pavilion.dot
LEISURE SERVICES. PARKS MEMORANDUM #01-69
TO Michael Rumpf, Director of Planning & Zoning
THRU John Wildner, Parks Director ~ ~ '1! a-/ tJ, \:.,(
FROM Barbara J Meacham, Landscape Architect ~^'-
RE East Boynton Medical Arts Pavilion
Date July 2, 2001
1 Submit detailed irrigation plans for required right-of-way landscape
improvements during the construction document permitting stage, for
review and approval by the Parks Division staff Include on the plan
location of any existing irrigation in the right-of-way
Plannine Memorandum. Forester I Environmentalist
To
LusIa Galav, PnncIpal Planner
From.
Kevm J Hallahan, Forester I EnvIronmentalIst
Subject:
East Boynton MedIcal Arts PavIlIon
NWSP # 01-004
1st RevIew
Date
July 3, 2001
The 35 eXIstmg non-natIve trees have not been mamtamed m optImal health and should be
replaced on the sIte. The 2 eXIstmg Sabal Palm trees should be relocated as part of the c1eanng
and grubbmg permIt. The applIcant should mdIcate on the landscape plan the replacement trees
for the 35 eXIstmg trees that WIll be removed from the SIte. The project should contmue m the
normal reVIew process.
Kjh
FIle
hi
1 .,
I
!
"
~'^- s. ,)r
d~
iVta/ Ol-()O~
f+ 2 {for - t~
C:,
CO-oi-
1
tD.---,;? ~ ,/I./~.dtcd
I
l
A7J!s. leo, f 1/ c.f'r'--
oc
1 I
c-
l!e I}! I &.:I7C-fL ~
o/,.dv /A4t
Ili:;(.,I~d..-
~C-;~
v~
;' j d2.t I~ 1-:) Svu /? / t....;>
/
V 2)(2-,./'('.74< {'i/l~YY-Y~4-
V dl.-r2'~~Y (S//(o!cJt)
V (1/
S'E- 29Th AlAZ - '~-.
c-! ()/V'.J~ R-(-~
~ ( c /, t/;
- c:. /51 1/4cB
ra,
~t
I d
~ /
V
01<--
(
c
? -
<--'
1.//
V a..~ ;}'~
.It
---b-L /-,PCt )1:.i;tC1
IJ --1-v6f-f-- V
1/
:leg
----
~1ov
~(Jrf1~ ~1 \~y
I 0[uJ; V\j ~
~1tv0 L.r
%~(S r
y~
C-'" "\ /
( ~_U:_1/P1"14-,-
1/-
--,/'"
;? ,/d
I~ fl f.
01 P. J, !
I vt, - L_'-''1-'}-~iI'? ~ :-1.0-
j..f", (' ;d' /", {j (j
I I.....J, /'0-- ~~
~
,
,
I 2--;L S ~
'1,( f '" / /'^ -, I J ~ S--
I v vc .:t'_'l"v' . f~
'7"'~"51 C J ,
~--)2 5~ C!CJ'YWvt((~_~
o
J /1 I',,/~ ()
I t::-.k; ::1 ( ,A? <:f -/ DG-,:'_ ilClt_ uL
/
~
10
"I
?--+-t.
I) ___
~ 1''t
I
'2
---
/2--
~.../-..~:) IQ--':y~ ,:-';'-;0-. ( ';;-te; nt. '7''' Y---/..t2
{...., J r -.::L 11 .., \
U; -/ J.e ('. ( 1+. ,L j
I '
;r.L { !) / G (j-0 C! J Ct'.._ U l' ::;I...d-tL -:~ j eel ~ {~
v
- -~-...~~ -,.,.
~ 112~.u
1
~.
'<
......-'
11_7_.[ ~L
t':
,.:J-.; ,--;.-<.-,,..;) _ \'_ .....,~
I v . -, ,~.,
~
~c'lr~
cL!-~..)
.~; <! ~ i1,C;~vnLR_r-u...y ! .--t.;/y.d/Jt~.~ '( ~ /)~
(' c;. Y, ~C -:;. F /,)
,
<:
.-I -1"
--:.:
r,'a.:;:>
/
,
(' ,
, -",i.
.
Y--~ 1
:--"~
--'!~'"/
.L
--'
./
--'.-.J _~;
/
! -
/i ~-'
;--
r1',
.
f~i
" I" , J . i -
-, v "'"'; ~>.........I
\; -
;7 s-:{: {I u'Y1.b.<.,;; ~ /'-..{
[iJ.. rl__
~ I :t,-L (~
..1!. r'4).{A.,e€_",,"
/ '(
{/
~
v
r~
I I
-:f .. / 'l.
A-:;;
r-~'" .(_~...
)
._ '<<--/'_,'~;' W / -<!.1;1_L /:/.} ,-::-;/ I
J__ - ~C ' ,
o _~)~-L0j 1,1 h.c?..f ;JJJ- ,c-"J..)'::U
.------------------y~r .Pu/CL- :.f.~J..-{.t?S-7\2,(AP -.. t. J '
I "" - I - 0...- t "'- I
__1
'/ ,--lie. ,1
-- '-...,J).....AJ
/l
/.
,1j;,~J
;) rc./ tv. z.,ftJ /<J.1Vl
JlJ- -th." Cl-.flCk e;(/'2w!j
)
t'
-r:. I{
i! _~I{ !t.fi.~-----iL--L'"______~::._,_____'_''+~.lf_- J-.J cG-:-I-____
I /, ,,r'..L I
.-e r _I/'-t-J r ~ U! it-t (1:.- .....1t y..1~_ ~~ :l--'1!~! Q ic_ ~-~u 111-';~_____
- '-~.---.--7-------------- - --------'----''=,.
r _j/'
f
f .,
-<-
1.__
/
--.!
ufPARTMENT OF DEVELOPMENT
MEMORANDUM NO PZ 01-126
fILE COpy
TO
TRC MEMBERS
Bob Borden, Deputy Fire Marshal
Kevin Hallahan, Forester/Environmentalist
James Predtinari, Police Department
H David Kelley Jr , Utilities Department
Timothy K. Large Building Division
Ken Hall, (Engineering) Public Works-General
Jeffery Livergood, Public Works-Traffic
Barbara Meacham, Parks Division
Laurinda Logan, Engineering Department
Lusia Galav, Planning Department
FROM
Michael W Rumpf
Director of Planning and Zoning
DATE.
June 26, 2001
RE
SITE PLAN REVIEW PROCEDURES
1 ST Review - New Site Plan
Project East Boynton Medical Arts Pavilion
Location - 2800 S Sea crest Blvd
Agent Kilday & Associates, Inc.
File No NWSP 01-004
Find attached for your review the plans and exhibits for the above-referenced project. Please review the
plans and exhibits and transmit formal written comments or e-mail to Elizabeth Cabrera and I no
later than 5.00 P.M. on Julv 10. 2001. When preparing your comments, please separate them into
two categories, code deficiencies with code sections referenced and recommendations that you
believe will enhance the project.
Adhering to the following review guidelines will promote a comprehensive review and enable the
applicant to efficiently obtain Technical Review Committee approval
1 Use the review standards specified in Part IV, Land Development Regulations Site Plan Review
and the applicable code sections of the Code of Ordinances to review and formulate comments
2 The documents submitted for the project were determined to be substantially complete with the
exception of traffic data, however, if the data provided to meet the submittal requirements is
insufficient to properly evaluate and process the project based on the review standards or the
documents show code deficiencies, additional data and/or corrections should be requested by the
reviewer by contacting Lusia Galav, or myself
3 Each comment shall reference the section of the code that is incorrectly depicted on the
documents.
4 Technical Review Committee member(s) shall identify in their comments when the plans depict or
when the location and installation of their departmental required improvements may conflict with
other departmental improvements
Page 2
5 When a TRC Member finds a code deficiency that is outside of his/her review responsibility, the
comment and the specific code section may be included in their review comments with the name of
the appropriate TRC Member that is responsible for the review specified
6 If a TRC member finds the plans acceptable, he/she shall forward a memorandum, within the time
frame stated above, to me The memorandum shall state that the plans are approved and that they
do not have any comments on the plans submitted for review and that they recommend the project
be forwarded through the approval process
All comments shall be typed addressed and transmitted or e-mailed to Elizabeth Cabrera and I for
distribution to the applicant. Please include the name and phone number of the reviewer on this
memorandum or e-mail Lusia Galav will be the Planning and Zoning staff member coordinating the review
of the project. First review comments will be transmitted to the applicant along with a list of Technical
Review Committee (TRC) members
MWR.lg
Attachment
XC Steve Gale, Fire Marshal
Marshall Gage, Police Department
John Guidry, Utilities Director and Interim Director of Engineering
Don Johnson, Building Division
Central File
S:\Planning\SHAREO\WPlFORMS\Templates and forms\TRC Memo for 1st Plans Review .doc
Revised 5-22-01