Loading...
CORRESPONDENCE Department of Engineering and Public Works PO. Box 21229 West Palm Beach. FL 33416-1229 (561) 684-4000 www.pbcgov.com . Palm Beach County Board of County Commissioners Karen T. Marcus. Chair Tony Masilotti. Vice Chairman Jeff Koons Warren H. Newell Mary McCarty Burt Aaronson Addie L. Greene County Administrator Robert Weisman An Equal Opporruniry Affirmarive Aerion Employer" @ printed on recycled paper February 14 2003 Mr Michael W Rumpf Director of Planning & Zoning Department of Development City of Boynton Beach POBox 310 Boynton Beach FL 34425-0310 RE. Quantum Park - Parcel 89B TRAFFIC PERFORMANCE STANDARDS REVIEW Dear Mr Rumpf' The Palm Beach County Traffic Division has reviewed the traffic statement for the residential project, pursuant to the Traffic Performance Standards in Article 15 of the Palm Beach County Land Development Code The project is summarized as follows Location Quantum Park - East of High Ridge Road North of Gateway Boulevard Boynton Beach 36 MF Residential Units. 252 nla Municipality. Proposed Uses. New Daily Trips. Build-out Year' Based on our review the Traffic Division has determined that the project is part of the previously approved Quantum DRI and therefore meets the Traffic Performance Standards of Palm Beach County If you have any questions regarding this determination please contact me at 684-4030 Sincerely OFFICE OF THE COUNTY ENGINEER j/V! an ? 1 ")nM l..) rD) l.. wu.J Masoud Atefi MSCE i Sr Engineer - Traffic pivisio "- ee: Eric Penfield, P.E. Sr Transportation Engineer -Calvin, Giordano & Associates Inc. -----------. [ E;:;j1 PT~'_-~r_!',; r C c -. -------- File. General TPS Mun - Trafie Study Review F \TRAFFIC\ma\Admin\Approvals\030204 doc 9\ ~ Q 1800 Eller Drive Suite 600 Fort Lauderdale. Aorida 33316 (954) 921-7781 (954) 921-8807 fax ';it 560 Village Boulevard Suite 340 West Palm Beach. Aorida 33409 (561) 684-6161 (561) 684-6360 fax CalVin, Giordano S Associates, Inc. Engineers Surveyors Planners 'W m maWfffn) ,I' , fIB 6am j' L February 5, 2003 ----- Quantum Park Property Owner's AsSOciatIOn, Inc. Quantum Arclutectural ReVIew Committee (ARC) 2500 Quantum Lakes Dnve SUIte 100 Boynton Beach, Flonda 33426 Attn. IulIe Finch RE. Quantum Village at Quantum Park Lots 83-88 and 89b-Architectural Review Committee Submission CGA Project No. . 02-2544.2 Dear Ms. Finch. Per our telephone conversatIOn last week, and your request at that time, we are submitting the following supplementary mformation for review by the Architectural ReVIew Committee. You should already be In receipt of two (2) copies of the proposed residentIal budding elevations, gatehouse, clubhouse, site plan and entry walls With color/paint swatches. In addition to those Items, we are submittIng two (2) copies of the follOWIng: . Boundary and Topographic Surveys - Timothy M. Smith, Land SurveYIng, Inc. . Site Plans and Details - CalVIn, Giordano and AsSOCiates, Inc . PavIng, GradIng, Drainage, Water, Sewer, Pavement MarkIngs and Slgnage Plans- CalVIn, GIOrdano and ASSOCiates, Inc. . Landscape Plans and Details~alvin, Giordano and ASSOCiates, Inc . Site LightIng, Photometncs and Details - Norman F Bray, P.E., Inc. . Architectural Plans and Elevations - CVV and Partners, ArchltectIPlanner . Traffic Impact Study-CalVIn, Giordano and ASSOCiates, Inc . EnVironmental Assessment - EnVIronmental ServIces, Inc. The prevIous submiSSion Included copies of the elevatIons and color swatches for the dwellIng, guardhouse and clubhouse. Please note the clubhouse elevation has been modified to Include a gable and pOrtiCO ThiS was done to proVide a consistent architectural style and roofhne throughout the project area. The proposed entry walls are compatible With, but not a replIcation of the Quantum master plan monument sign. The Quantum monument sign IS commerciaVlight Industrial In deSIgn and materials, and as such an exact replIcation of It for a reSidential use IS Inappropnate. The color scheme and use of green hues IS Intended to umfy the residentIal entry signage With the Quantum master plan entry SIgh, as well as complIment and reflect the color scheme for the reSidential structures. Quantum Architectural Review Committee Attn. Julie Finch February 5. 2003 Page 20/2 The City of Boynton Beach does not require finite locations for dwellmg compressor umts, meters and FP&L transformers for Technical Review Committee (TRC) approval. Those Items will be reviewed throughout the penmtting process and are conditions of the Development Order (DO). At tlns time, the applicant is consldenng placing the arr conditioner compressors in either the pnvate patios or in a mche created between adjacent rear loaded garages. One electric transformer Will be requrred for every two buildings contained on the site plan. Transformers will be located m the open spaces between the curb and front or side bUIlding fa~des. All transformers and meters will be screened as depicted on the landscape details and notes. We appreciate your favorable consideration of this project and submission packet and look forward to your response. Should you have any questions regarding the Information contamed herem, please do not hesitate to contact me at (561) 684-6161 Very truly yours, CALVIN, GIORDANO & ASSOCIATES, INC. /aa-c ~ Paul Guariglia, RLA Director of Landscape Arclutecture Cc: BiiiiGtlav, AICP (City of Boynton Beach) Ene Johnson, AICP (City of Boynton Beach) Mark Bulwell (Westbrooke Companies, Inc.)~. Tammy Cook, RLA (Calvm, GIOrdano & AssOciates) Sara Lockhart, AICP (Calvm, GIOrdano & Associates) Ene Penfield (Calvm, GIordano & AssocIates) S:\Land\02-2544 Quantum Village at Boynton Beach\Traffic AnalysislTraffic Conwm:ncyIl.tr Julie ARC 01_31_ 03.doc m1 Calvin, Giordano & Associates, Inc. Engineers Surveyors Planners WEST PALM BEACH OFFICE 560 Village Boulevard, Suite 340 West Palm Beach, Florida 33409 Phone (561) 684-6161 Fax (561) 684-6360 f58rcnMR ;~ tLr; ~ U V l f I-n' f: ~ Ii . I \ I . ! JAN - 7 2003 :1 ~li (' rND __ _~~_____~_J~G D[PT MEMO DATE January 2, 2003 TO Mr Steve Gale, Deputy Chief, Boynton Beach Fire-Rescue FROM Tom Mueller, P.E. COPY File SUBJECT Quantum Village Fire Flow Requirements CGA PROJECT NO' 02-2544 As reqUIred by City Ordmance, we have prepared a water model on the water mam for thIS project to show that the system will meet the 1,500 GPM at 20 P.S.!. fire flow reqUIrement. We modeled tlus system usmg the fire flow data proVIded to us by your office on August 5th 2002 for the two fire hydrants nearest thIS sIte. The model was prepared usmg WaterCAD verSIon 5 0 from Haestad Methods, Inc. A demand of 1500 gallons per mmute (gpm) was placed on the proposed system at the most extreme hydrant locatIOns. ThIs was done on both the West and East SIdes of High RIdge Road. At a flow of 1,500 the pressure at the most extreme hydrant on the West SIde was calculated to be 35 17 pSI, and the pressure at the most extreme hydrant on the East SIde was calculated to be 38 44 pSI. Please note that thIS pressure IS greater than the reqUIred 20 pSI. We also ran the WaterCAD fire flow analYSIS and found that the constramts were met. For your use, I have attached copIes of the JunctIon and fire flow reports for both the East and West systems. Please call me If you have any questIons or If you need anythmg else. Thank you. Scenario Base Fire Flow Analysis Junction Report Label Elevation Zone Type Base Flow Pattern Demand Calculated Pressure (ft) (gpm) Calculated ~ydraulic Grad (psi) (gpm) (ft) J-1 0.00 Zone-1 Demand 0.00 Fixed 000 98.87 42.78 J-2 000 Zone-1 Demand 0.00 Fixed 000 9887 42.78 J-3 000 Zone-1 Demand 0.00 Fixed 000 100.93 43.67 J-4 0.00 Zone-1 Demand 0.00 Fixed 0.00 100 97 43.69 J-5 0.00 Zone-1 Demand 000 Fixed 000 101 13 43.76 J-6 000 Zone-1 Demand 000 Fixed 0.00 101 15 43.76 J-7 000 Zone-1 Demand 0.00 Fixed 000 101 19 43.78 J-8 0.00 Zone-1 Demand 0.00 Fixed 000 101.55 43.94 J-9 000 Zone-1 Demand 0.00 Fixed 0.00 101.62 43.97 J-10 000 Zone-1 Demand 000 Fixed 000 101.68 43.99 J-11 0.00 Zone-1 Demand 0.00 Fixed 0.00 98.26 42.51 J-12 0.00 Zone-1 Demand 0.00 Fixed 0.00 102.04 4415 J-13 000 Zone-1 Demand 000 Fixed 0.00 102.37 44.29 J-14 000 Zone-1 Demand 000 Fixed 000 102.36 44.28 J-15 000 Zone-1 Demand 000 Fixed 0.00 104 17 45.07 J-16 0.00 Zone-1 Demand 0.00 Fixed 0.00 104.39 45.17 J-17 0.00 Zone-1 Demand 0.00 Fixed 0.00 103.28 44.68 J-18 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.69 45.73 J-19 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.69 45.73 J-20 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.69 45.73 J-21 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.67 45.72 J-22 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.69 45.73 - J-23 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.70 45.73 J-24 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.71 45.74 J-25 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.73 45.75 J-26 0.00 Zone-1 Demand 0.00 Fixed 0.00 104 79 45.34 J-27 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.67 45.72 J-28 0.00 Zone-1 Demand 0.00 Fixed 0.00 105 67 45.72 J-29 0.00 Zone-1 Demand 000 Fixed 0.00 105.67 45.72 J-30 0.00 Zone-1 Demand 0.00 Fixed 0.00 106.36 46.02 J-31 0.00 Zone-1 Demand 1,500.00 Fixed 1,500.00 88.86 38.44 J-32 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.69 45.73 J-33 000 Zone-1 Demand 0.00 Fixed 0.00 101 15 43.76 J-34 0.00 Zone-1 Demand 0.00 Fixed 0.00 101.55 43.94 J-35 0.00 Zone-1 Demand 0.00 Fixed 0.00 100.97 43.69 J-36 0.00 Zone-1 Demand 0.00 Fixed 0.00 103.28 4468 J-37 000 Zone-1 Demand 0.00 Fixed 0.00 102.36 44.28 J-38 0.00 Zone-1 Demand 0.00 Fixed 0.00 104 79 45.34 J-39 0.00 Zone-1 Demand 0.00 Fixed 0.00 10570 45.73 J-40 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.69 45.73 J-41 0.00 Zone-1 Demand 0.00 Fixed 000 105.67 45.72 Project Engineer' David Cohen p:\. \calculations\watercad\quantum rev wed Calvin Giordano & Associates fnc WaterCAD v5.0 [5.0037] 12/20/02 09:02:46 AM @Haestad Methods, Inc. 37 Brookside Road Waterbury CT 06708 USA +1 203-755-1666 Page 1 of 1 Scenario Base Fire Flow Analysis Junction Report Label Elevation Zone Type Base Flow Pattern Demand Calculated Pressure (ft) (gpm) Calculated ydraulie Grad (psi) (gpm) (ft) J-1 000 Zone-1 Demand 000 Fixed 000 105.68 45.72 J-2 0.00 Zone-1 Demand 000 Fixed 000 105.68 4572 J-3 000 Zone-1 Demand 000 Fixed 000 105.69 4573 J-4 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.69 45.73 J-5 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.69 45.73 J-6 000 Zone-1 Demand 0.00 Fixed 000 105 69 4573 J-7 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.69 45.73 J-8 0.00 Zone-1 Demand 000 Fixed 0.00 105.69 45.73 J-9 0.00 Zone-1 Demand 0.00 Fixed 000 105.69 45.73 J-10 000 Zone-1 Demand 0.00 Fixed 0.00 105.69 45.73 J-11 000 Zone-1 Demand 0.00 Fixed 0.00 105.68 45.72 J-12 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.68 45.72 J-13 000 Zone-1 Demand 0.00 Fixed 0.00 105.69 4573 J-14 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.68 45.72 J-15 000 Zone-1 Demand 0.00 Fixed 000 105.66 4571 J-16 0.00 Zone-1 Demand 000 Fixed 0.00 105 71 45.73 J-17 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.70 45.73 J-18 0.00 Zone-1 Demand 0.00 Fixed 0.00 95.43 41.29 J-19 0.00 Zone-1 Demand 0.00 Fixed 0.00 92.16 39.87 J-20 0.00 Zone-1 Demand 0.00 Fixed 0.00 100.09 43.30 J-21 0.00 Zone-1 Demand 0.00 Fixed 0.00 10443 45.18 J-22 0.00 Zone-1 Demand 0.00 Fixed 0.00 100.75 43.59 ~ J-23 0.00 Zone-1 Demand 0.00 Fixed 0.00 103.16 44.63 J-24 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.61 45.69 J-25 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.73 45.75 J-26 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.61 45.69 J-27 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.53 45.66 J-28 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.48 45.63 J-29 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.48 45.63 J-30 0.00 Zone-1 Demand 0.00 Fixed 0.00 106.36 46.02 J-31 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.68 45.72 J-32 0.00 Zone-1 Demand 1.500.00 Fixed 1.500.00 81.30 35.17 J-33 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.69 45.73 J-34 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.69 45.73 J-35 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.69 45.73 J-36 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.70 45.73 J-37 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.68 45.72 J-38 0.00 Zone-1 Demand 0.00 Fixed 0.00 105.61 45.69 J-39 0.00 Zone-1 Demand 0.00 Fixed 0.00 103.16 44.63 J-40 0.00 Zone-1 Demand 0.00 Fixed 000 100.75 43.59 J-41 0.00 Zone-1 Demand 0.00 Fixed 0.00 10401 45.00 Project Engineer' David Cohen p.\. \calculations\watercad\quantum rev wed Calvin Giordano & Associates Inc WaterCAD v5.0 [5.0037] 12/20/02 09:0444 AM @ Haestad Methods. Inc. 37 Brookside Road Waterbury CT 06708 USA +1-203-755-1666 Page 1 of 1 Scenario Base Fire Flow Analysis Fire Flow Report Label Zone Fire Flo\ll Fire Flow Satisfies Needed Available Total Total Residual Calculated Jlinimum Zon Calculated teratiom ~alanced . Fire Flow Fire Flow Fire Flow Flow Pressure Residual Pressure Minimum onstraints (gpm) Flow Needed Available (psi) Pressure (psi) Zone (gpm) (gpm) (gpm) (psi) Pressure (psi) J-1 Zone-1 13 true true 1,500.00 2,288.27 1,500 00 ~,288.27 20.00 20.00 2000 2616 J-2 Zone-1 15 true true 1,500 00 2,531.57 1,500 00 ~,531 57 20.00 20.00 20.00 20.00 J-3 Zone-1 15 true true 1,500 00 2,571 03 1,500 00 ~,571.03 20.00 20.00 20.00 20.12 J-4 Zone-1 17 true true 1,500.00 2,523.53 1,500 00 ~,523.53 20.00 20.00 2000 20.00 J-5 Zone-1 16 true true 1,500.00 2,430.66 1,500.00 ~,430.66 20.00 2000 2000 2018 J-6 Zone-1 15 true true 1,500 00 2.362.38 1,500.00 ~,362.38 20.00 20.00 2000 20.00 J-7 Zone-1 16 true true 1,500.00 2,41505 1,500 00 ~,41505 20.00 2000 20.00 20.75 J-8 Zone-1 16 true true 1,500.00 2,48316 1,500.00 ~,483.16 20.00 2000 20.00 20.00 J-9 Zone-1 15 true true 1,500.00 2,545.85 1,500.00 ~,545.85 20.00 20.00 20.00 20.22 J-10 Zone-1 16 true true 1,500.00 2,628 14 1,500.00 ~,628.14 20.00 20.00 20.00 20.03 J-11 Zone-1 16 true true 1,500 00 2,546.20 1,500 00 ~,546.20 20.00 20.00 20.00 2000 J-12 Zone-1 15 true true 1,500 00 2,696.92 1,500.00 ~.696.92 20.00 20.00 2000 20.51 J-13 Zone-1 15 true true 1,500.00 2,721 45 1,500.00 ~,721 45 20.00 20.00 20.00 20.12 J-14 Zone-1 15 true true 1,500 00 2.698.75 1,500.00 ~,698.75 20.00 20.00 20.00 2000 J-15 Zone-1 17 true true 1,500.00 2,79445 1,500.00 ~,794 45 20.00 20.00 20.00 20.88 J-16 Zone-1 15 true true 1,500.00 2,854.20 1,500.00 ~,854.20 20.00 20.00 20.00 20.10 J-17 Zone-1 16 true true 1,500.00 2,759.93 1,500.00 ~,759.93 20.00 20.00 20.00 20.00 J-18 Zone-1 15 true true 1,500.00 2,427.66 1,500.00 ~,427.66 20.00 20.00 20.00 20.00 J-19 Zone-1 16 true true 1,500.00 2,309.94 1,500.00 ~,309.94 20.00 20.00 20.00 20.00 J-20 Zone-1 15 true true 1,500.00 2,631.00 1,500.00 ~,631.00 20.00 20.00 20.00 20.00 J-21 Zone-1 13 true true _ 1,500.00 2,782.29 1,500.00 ~,782.29 20.00 20.00 20.00 20.17 J-22 Zone-1 16 true true 1,500.00 2,636.74 1,500.00 ~,636.74 20.00 20.00 20.00 20.00 J-23 Zone-1 17 true true 1,500.00 2,70771 1,500.00 ~,707 71 20.00 20.00 20.00 20.00 J-24 Zone-1 16 true true 1,500.00 2,949.35 1,500.00 ~,949.35 20.00 20.00 20.00 20.00 J-25 Zone-1 13 true true 1,500.00 2,958.07 1,500.00 Z,958.07 20.00 20.00 20.00 20.00 J-26 Zone-1 14 true true 1,500.00 2,795.38 1,500.00 ~,795.38 20.00 20.00 20.00 20.00 J-27 Zone-1 15 true true 1,500.00 2,931.20 1,500.00 ~,931.20 20.00 20.00 20.00 20.00 J-28 Zone-1 17 true true 1,500.00 2,909.69 1,500.00 Z,909.69 20.00 20.00 20.00 20.21 J-29 Zone-1 15 true true 1,500.00 2,919.02 1,500.00 ~,919.02 20.00 20.00 20.00 20.00 J-30 Zone-1 1 true true 1,500.00 3,000.00 1,500.00 3,000.00 20.00 20.04 20.00 20.04 J-31 Zone-1 13 true true 1,500.00 2,196.35 1,500.00 ~,196.35 20.00 20.00 20.00 28.64 J-32 Zone-1 14 true true 1,500.00 2,006.19 1,500.00 Z,006.19 20.00 20.00 20.00 28.31 J-33 Zone-1 17 true true 1,500.00 2,041.39 1,500.00 ~,041.39 20.00 20.00 20.00 28.56 J-34 Zone-1 16 true true 1,500.00 2,081.89 1,500.00 ~,081.89 20.00 20.00 20.00 30.05 J-35 Zone-1 17 true true 1,500.00 2,18945 1,500.00 Z,189.45 20.00 20.00 20.00 28.35 J-36 Zone-1 16 true true 1,500.00 2,333.66 1,500.00 ~,333.66 20.00 20.00 20.00 29.63 J-37 Zone-1 16 true true 1,500.00 2,290.99 1,500.00 Z,290.99 20.00 20.00 20.00 29.43 J-38 Zone-1 16 true true 1,500.00 2,312.42 1,500.00 Z,312.42 20.00 20.00 20.00 30.67 J-39 Zone-1 16 true true 1,500.00 2,144.87 1,500.00 Z,144 87 20.00 20.00 20.00 32.63 J-40 Zone-1 17 true true 1,500.00 2,271.89 1,500.00 ~,271.89 20.00 20.00 20.00 28.69 J-41 Zone-1 14 true true 1,500.00 2,744.66 1 ,500 00 ~,744.66 20.00 20.00 20.00 21.24 Project Engineer' David Cohen p:\. \calculations\watercad\quantum rev wed Calvin Giordano & Associates Inc WaterCAD v5.0 [5.0037} 12/20/02 09'10:36 AM @ Haestad Methods, Inc. 37 Brookside Road Waterbury CT 06708 USA +1-203-755-1666 Page 1 of 2 Scenario Base Fire Flow Analysis Fire Flow Report Minimurli ~inimum Syste l:alculatec ~inimum Zone Pressure Minimum System Junction (psi) System Junction Pressure (psi) J-2 2000 -000 PMP 1 J-l 2000 -000 PMP 1 J-35 2000 -000 PMP 1 J-35 2000 -000 PMP 1 J-33 2000 -000 PMP 1 J-33 20.00 -000 PMP 1 J-33 2000 -000 PMP 1 J-34 2000 -000 PMP-l J-34 2000 -000 PMP 1 J-9 2000 -0.00 PMP 1 J-31 2000 -0.00 PMP-l J-14 2000 -000 PMP 1 J-l0 20.00 -000 PMP 1 J-37 2000 -0.00 PMP 1 J-37 20.00 -0.00 PMP-l J-17 2000 -000 PMP-l J-36 20.00 -0.00 PMP 1 J-19 2000 -000 PMP-l J-32 20.00 -000 PMP 1 J-18 20.00 -0.00 PMP-l J-41 20.00 -0.00 PMP 1 ~ J-40 20.00 -0.00 PMP-l J-39 20.00 -0.00 PMP-l J-23 20.00 -0.00 PMP-l J-34 20.00 -0.00 PMP-l J-38 20.00 -0.00 PMP-l J-28 20.00 -0.00 PMP 1 J-29 20.00 -0.00 PMP-l J-28 20.00 -0.00 PMP 1 J-34 20.00 -0.00 PMP 1 J-ll 20.00 -0.00 PMP-l J-19 20.00 -0.00 PMP-l J-6 20.00 -0.00 PMP 1 J-8 20.00 -0.00 PMP 1 J-4 20.00 -0.00 PMP-l J-17 20.00 -0.00 PMP 1 J-14 20.00 -0.00 PMP-l J-26 20.00 -000 PMP 1 J-23 20.00 -0.00 PMP-l J-22 20.00 -0.00 PMP-l J-21 20.00 -000 PMP-l Project Engineer' David Cohen p:\...\calculations\watercad\quantum rev wed Calvin Giordano & Associates Inc WaterCAD v5.0 [5.0037] 12/20/02 09:10:36 AM e Haestad Methods, Inc. 37 Brookside Road Waterbury CT 06708 USA +1-203-755-1666 Page 2 of 2 FLOW TEST CALVIN, GIORDANO AUG 0 5 2002 WPB OFFICE '8~ g'~ ?bte ~e4eeee Request Date 7/24/02 Company" Calvin Giordano & Assocs Requested From Tom Mueller 560 Village Blvd #340 West Palm Beach, FL 33409 Telephone Number. 561-684-6161 Facsimile Number" 561-684-6360 Location High Ridge Road - North of Gateway Boulevard * DIAGRAM * (Include direction, street names, hydrant locations, intersections and main sizes) r H 2600 I H#@ ED CAREY - DESIGN G H R N I 0 G H#<D 2400 E GATEWAY PROFESSIONAL BUilDING R D GATEWAY BOULEVARD Hydrant 1 Hydrant 2 Static Reading Flow Reading 56 psi 46 psi = 1141 gpm Residual Reading 50 psi Assign Date 7/24/02 Test Date 7/29/02 Tested By" FF III Woznick Time Tested 1245 hrs AVAILABLE GPM AT 20 PSI RESIDUAL 3006 gpm