CORRESPONDENCE
~(~
~f, Michael
From
Sent:
To
Cc:
Subject:
Livergood, Jeffrey
Friday August 13 2004 9 15 AM
Logan Laurinda
Kelley David Rumpf Michael
QP Village North
Laurinda,
I have reviewed the plans you provided me in order to best determine how to address the westbound merge lane on
Gateway Blvd What makes this difficult is the presence of the new driveways. My initial comments are as follows
1 There is no provision for a signalized intersection The developer is required to plan for this future action
2 Initially the signal was proposed to be closer to High Ridge As designed, only the far westerly driveway can
accommodate a traffic signal
3 The far westerly driveway is designed to accommodate a stop control only This should be changed
4 The far westerly driveway will be the high volume access route when a signal is constructed Unfortunately this is
located at a critical spot on the westbound merge lane taper
5 I like the bus stop turnout past the westerly driveway This is a nice safety feature However, it too must be considered
in the design of the signal and merge lane
Recommendations.
I believe that the merge lane should be accounted for on Gateway Blvd WEST of the bus lane There should not be a
merge lane in the vicinity of driveways or the bus turnout. This is too confusing to motorists The area is too "busy" as
presently designed We can't have a merge lane extend through a traffic signal Vehicles must be in their designated
through lane before and after the signal Therefore three westbound through lanes must be designed on Gateway from
High Ridge to a point just west of the bus turnout. From this point, I suggest that the merge lane be constructed I
recognize that this increases the amount of off site improvements required Particular attention will have to be given to the
impact on the Premier driveway/right turn lane as well I will welcome other suggestions from the developers professional
design team They must be creative to solve this It is not a matter of accommodating traffic volume The issue is safety
Jeff
Jeffrey R. Livergood P E
Director of Public Works
City of Boynton Beach
1
02/25/2004 16 47 195442~ ~9
KENCARLSONARCHI~ ~TS
PAGE 01/02
KENf'JETH
CARLSON
ARCHITECT - p t\
DES I G r'J
P L i\ ;J r J I ,'.J G .
I r\1 T E RIO R S
KE'Nf'.JJ;TH, ,R.-. CA,Rh~QN' ~ .AR,CHITECT, P.A
"
LETTER OF TRANSMITTAL
AA CU01878
PrOject #. ,,~, /()!J
# of Pages. ,...
To' ~lud~shcel)
Fax Memo
Date ~Z!:/6tf
.
Time: 'I: '/( ptn
-
ce.
Fax #.~.... 74t bZS'1
t%1 14'2.. 'Ui1.
Company' ~ ~ ~ ~.
From. K&J ~u
Subject: ~h1- RJ,\~ r.J.v
Comments.
1002 e Newport Center Drive, Suite 101 Deerfield Beadl. FL. 33442 Phone (954) 427-8548 Fax (954) 427-9929 www.kencartSon.com
02/25/2004 16 47
195442"" "29
KENCARLSONARCHI TrCTS
PAGE 02/02
~
-A't
J1 oil JO
~~Ij
Iltt
118
3!\ ! i
III
! :jl
~ ~
r ~J~
j. i :111' ;,'
K~ cr~ ~~ i~1
:~f
I~
g ~
,~ ~
.s:>~
>~ 2
= :J.
.......(r
j ~
Jt\~
~f
B t
~Ji
l~! ;!
..
! I
. . i~"'I'" ".J,t :~.,~z~~~:.,,:
!
I
I
I
I I :
o
o
~
~
1Il
~
~
f
II !
i .n /'.
I ,~ .-.-'" . .
I __~ ~ .-_~
~: L.II".... !IlIOGiE ~<l,t: --:.__---.-"'- ~ ",-
.---.-1---.-.----1.------- - --.-.-----------
- --.- ----- ---.-.- ~
'KENNETH
CARLSON
ARCHITECT ~ PA
DESIGN
PLANNING.
INTERIORS
KENNETH R CARLSON - ARCHITECT P A
.. '
AA C001878
1'"1
a208M
January 20, 2004
CIty of Boynton Beach
100 E. Boynton Beach Blyd.
Boynton Beach, FI 33425
RESPONSES TO PLANNING AND ZONING COMMENTS
for
QUANTUM PARK & VILLAGE NORTH COMMERCIAL
(QUANTUM PUBLIX)
City of Boynton Beach File Number: NWSP 03-023
Public Works - General.
1 Pnor to perrmt applIcatIOn contact the PublIc Works Department (651-742-6200)
regardmg the storage and handlIng of refuse
<KRC> We agree to this requirement and Public Works Department will be
contacted.
2 The actual number of dumpsters reqUIred at thIS SIte may need to be mcreased based
on usage
<KRC> Double dumpster provided behind Publix building, see sheet A3 O.
3 Adjust the angle of the dumpster m the northwest comer to allow a straIght III
approach from eIther the south or the east.
<KRC> See revised drawing on sheet A3 O.
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.Gom
KENNETH
CARLSON
ARCHITECT - P.A
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON - ARCHITECT, P A
AA C001878
4 Adjust the angle of the dumpster north ofbU1ldmg "F" to provIde a mImmum
backmg clearance of 60 feet. (measured form the front edge of the dumpster pad)
<KRC> See revised drawing on sheet A3. O.
5 IdentIfy the dumpster or compactor for the PublIx Supermarket.
We have IdentIfied the dumpster - see_
<KRC> See provided note on sheet A3 O.
6 ProvIde a nummum turnmg radIUs of 60 feet to approach all dumpster I compactors
ProvIde a nummum backmg clearance of 60 feet. (measured from the front edge of
the dumpster I compactor pad.) LDR, Chapter 2, SectIon 11.1.2 b)
<KRC> Provided minimum backing clearance of 60 ft. see sheet A3 O.
7 Ensure vertIcal clearance at all enclosures Possible conflIcts are noted between
proposed LIve Oaks and proposed enclosure locatIOns
<LDS> The trees were moved or adjusted to allow clearance.
Public Works - Traffic.
8 On the SIte and CIVIl plans, show and IdentIfy all necessary traffic control devIces
such as stop bars, stop SIgnS, double yellow lane separators strIpmg, dIrectIOnal
arrows and "Do Not Enter" sIgnage, etc Delmeate and strIpe the "Loadmg Area"
(where applIcable - LDR, Chapter 2, SectIOn 11 1), mclude a pavement message m
yellow mdIcatmg "No Parkmg - Loadmg Zone" See CIty Standard Drawmgs "K"
Senes for strIpmg detaIls
<East Bay> The site/civil development plans have been revised to indicate all
traffic control devices. All loading areas are striped and the pavement is
marked "No Parking - Loading Zone"
9 FIre lane sIgnage and markmgs shall conform to LDR Chapter 23, ArtIcle II,
SectIOn "B" & "M" The 3-foot hIgh "FIre Lane" words shall be placed along both
lanes and staggered. Please note thIS reqUIrement IS applIcable to bUIldmgs WIth a
gross area greater than 15,000 SF
<East Bay>
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - PA
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON - ARCHITECT, P A
AA coo 1878
10 Where possible place handIcap stalls adjacent to the retaIl bUIldmgs As an
example, some or all of the handIcap spaces on the west sIde of PublIc could be
placed m the spaces adjacent to the bUIldmg on the north sIde of the bUIldmg
<KRC> One handicap parking space provided on the west side of Publix, see
sheet A3 O.
<East Bay> All handicap stalls have been situated as close to the retail buildings
as possible. Publix requires handicap stalls be placed in the front extents of their
parking field and close to the main entrance.
11 Show all Improvements for Gateway Blvd. and HIgh RIdge Rd.
<East Bay> Gateway Boulevard improvements are already shown on the site
development plans. We are unaware of any roadway improvements for High
Ridge Road.
12 Add a general note to the sIte plan that (all plans subnntted for specIfic permIts shall
meet the CIty'S Code reqUIrements at tIme of applIcatIOn. These permIts mclude, but
are not lInnted to the followmg Pavmg, dramage, curbmg, sIte lIghtmg, landscapmg
and ImgatIon. PermIts reqUIred from other permIttmg agencIes such as Flonda
Department of TransportatIOn, (FDOT), South Flonda Water Management DIStnCt
(SFWMD), Lake Worth Dramage DIStnCt (LWDD), Flonda Department of
EnVIronmental ProtectIOn (FDEP), Palm Beach County Health Department
(PFCHD), Palm Beach County EngIneenng Department (PBCED), Palm Beach
County Department of EnvIronmental Resource Management (PBCDERM) and any
others shall be mcluded WIth the permIt request.)
<KRC> Note included on Site Plan, see sheet A3 O.
<East Bay> A note has been added to the site development plan regarding plan
submiual meeting City's Code requirement.
13 All comments reqUInng changes and/or correctIOns to the plans shall be reflected on
all appropnate sheets.
<KRC> We agree to make the changes to all the plans sheets affected by any
change.
<East Bay> All changes/corrections are documented in the revision block on the
appropriate sheets.
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - P.A.
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON - ARCHITECT P A
,
AA C001878
14 Please note that changes or reVISIons to these plans may generate addItIonal
comments Acceptance of these plans dunng the TRC process does not ensure that
addItIOnal comments may not be generated by the ConumssIOn and at penmt
reVIew
<KRC> We understand that additional changes may be necessary from sources
stated above.
15 SpeCIfy use of the FDOT Standard SpecIficatIOns for Road & Bndge ConstructIOn
and Standard Index, 2000 EdItIon, as the constructIOn standard.
<East Bay> A note has been added to the Paving & Drainage Plan sheets
specifying the use of FDOT Standard Specifications.
16 The hghtmg deSIgn shall provIde a rmmmum average hght level of one foot candle
The average hghtmg levels proposed for the Pubhx parkmg lot are well m excess of
that value LIghtmg shall not be used as a form of advertIsmg m a manner that
draws more attentIOn to the bUIldmg or grounds at mght than m the day (LDR<
Chapter 9, SectIOn 10.F 5) LIghtmg shall be dIrected away from any reSIdentIal
uses (LDR< Chapter 23, ArtIcle II, SectIon A.l a)
<KRC> The higher average lighting levels proposed for the parking lot are
Publix's requirement and they are implemented to insure safety of Publix
costumers. They are not form of advertising
17 It may be necessary to replace or relocate large canopy trees adjacent to hght
fixtures to ehrmnate future shadowmg on the parkmg surface (LRC, Chapter 23,
ArtIcle II, SectIOn A.I b)
<LDS> The trees were adjusted or removed to allow clearance for the proposed
lights. A note was also added to the landscape plan to this affect.
18 Show SIght tnangles on the landscape plan (LRC, Chapter 7 5, ArtIcle II, SectIOn
5.h) Reference FDOT Standard Index 546 for the SIght tnangles along Gateway
Blvd. and HIgh RIdge Rd.
<LDS> The landscape plans show the sight triangles with appropriate
landscaping within.
19 IndIcate, by note on the landscape plan, that wIthm the SIght triangles there shall be
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 4279929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - P.A.
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON - ARCHITECT P A
I
AA C001878
an unobstructed cross-vIsibIlIty at a level between 2 5 feet and 8 feet above the
pavement (LDR), Chapter 6, ArtIcle IV, SectIOn 5 wIll be reqUIred at the tIme of
perrruttmg
<LDS> A note was added to the landscape plans to this affect.
20 ProvIde an engIneer's certIficatIon on the drainage plan as specIfied m LDR,
Chapter 4, SectIOn 7.F.2 Full dramage plans, mcludmg dramage calculatIOns, m
accordance WIth the LDR< Chapter 6, ArtIcle IV, SectIOn 5 wIll be reqUIred at tIme
of perrruttmg.
<East Bay> A note has been added to the Paving & Drainage Plan sheets
specifying the compliance of the drainage system to the City's Land Development
Regulations.
21 IndIcate by note that catch basm and manhole covers shall be bIcycle proof (LDR,
Chapter 6, ArtIcle IV, SectIOn 5.A.2 g)
<KRC> Note was provided, see sheet A3.0.
22 SpeCIfy storm sewer dIameter, mlets types, etc on dramage plan. IndIcate grate, nm
and mvert elevatIOns for all structures. IndIcate grade of storm sewer segments
IndIcate matenal specIficatIon for storm sewer
<East Bay> Details on the storm sewer system (storm sewer diameters, pipe
material, grate/rim elevations and inlet types) are indicated on the Paving &
Drainage Plan.
23 Pavmg, Dramage and SIte detaIls wIll not be revIewed for constructIOn acceptabIlIty
at thIS tIme All engmeenng constructIOn detaIls shall be m accordance WIth the
applIcable CIty of Boynton Beach Standard Drawmgs and the "Engineerzng DeSIgn
Handbook and ConstructlOn Standards" and WIll be revIewed a the tIme of
constructIon perrrut applIcatIon.
<East Bay> It is noted that specific details will not be reviewed for construction
acceptability at this time.
Utilities
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - P.A.
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON - ARCHITECT, P A
AA C001878
24 All utIlIty easements shall be shown on the rectIfied sIte plan (as well as the Water
and Sewer Plan sheet and landscape drawmgs) so that we may deternnne WhICh
appurtenances, trees or shrubbery may mterfere wIth utIlItIes In general, palm trees
wIll be the only tree speCIes allowed wIthm utIlIty easements Canopy trees may be
planted outSIde of the easement so that roots and branches WIll not Impact those
utIlItIes wIthm the easement m the foreseeable future The LDR, Chapter 7 5,
ArtIcle, SectIOn 18 I gIves publIc utIlItIes the authonty to remove any trees that
mterfere wIth utIlIty servIces, eIther m utIlIty easements or publIc nghts-of-way
Proposed easements are shown on the utIlItIes plan and landscape plan, whIch WIll
assIst greatly m thIS reVIew process.
Water and sewer lmes to be owned and operated by the CIty shall be mcluded
wIthm utIlIty easements Please show all proposed easements on the engmeenng
drawmgs, usmg a rmmmum WIdth of 12 feet. The easements shall be dedIcated VIa
separate mstrument to the CIty as stated m CODE Sec 26-33(a)
As an example, the eXIstmg wastewater easement traversmg the project (adjacent to
proposed BUIldmg "F" m a southerly dIrectIOn IS not adequately addressed as to ItS
realIgnment, reconstructIOn, etc ThIS eXIstmg wastewater lme IS some 13 to 14 feet
deep, WhICh reqUIres at least a 30-foot WIde utIlIty easement, WhICh IS not reflected
on the proposed plans
As a rule of thumb prOVIde a rmmmum easement equal to two tImes the depth of the
samtary sewer and centered on the samtary sewer lme For combmed easements the
overall WIdth WIll be equal to the depth of the samtary lme plus 10 feet for water/
samtary sewer mam separatIon plus an addItIonal 6 feet past the water lme Thus
for the combmed easement north ofbUIldmg "E" prOVIde a mImmum 30 foot
easement.
Changes m easement WIdths may reqUIre changes m utIlIty alIgnments to resolye
conflIcts WIth bUIldmgs or other structures
<East Bay> Water and sewer lines are included within the minimum 12 foot
wide utility easement as shown on the Water & Wastewater Plan.
1002 E Newport Center Drive. Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - P.A.
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON - ARCHITECT, P A
AA C001878
25 ?
26 Palm Beach County Health Department perrmts wIll be reqUIred for water and
sewer systems servmg thIS project (CODE, SectIOn 26-12)
<East Bay> Palm Beach County Health Department approval will be obtained
when required
27 FIre flow calculatIons wIll be reqUIred demonstratmg the CIty Code reqUIrement
of 1,500 g.p.m. as stated m the LDR< Chapter 6, ArtIcle IV, SectIOn 16, or the
reqUIrement Imposed by Insurance underwnters, whIchever IS greater (CODE,
SectIOn 26-16(b)
<East Bay> Fire flow calculations will be submitted prior to approval from
utilities.
28 The CODE< SectIOn 26-34(E) reqUIres that a capacIty reservatIOn fee be paId for
thIS project eIther upon the request for the Department's sIgnature on the Health
Department applIcatIOn forms or wIthm 30 days of sIte plan approval, whIchever
occurs first. ThIs fee wIll be determIned based upon final meter SIze, or expected
demand.
<East Bay> A capacity reservation fee will be paid prior to the submittal to the
Health Department application or within 30 days of site plan approval.
29 ComprehensIve Plan PolIcy 3 C 3 4 reqUIres the conservatIOn of potable water
As other sources are readIly avaIlable CIty water shall not be allowed for
ImgatIon.
<East Bay> Potable water will not be used for irrigation. Irrigation water will
be supplied by separate wells.
30 ThIS office wIll not reqUIre surety for mstallatIOn of the water and sewer utIlItIes,
on condItIOn that the system be fully completed, and gIven to the CIty UtIlItIes
Department before the first permanent meter IS set. Note that settmg of a
permanent water meter IS a prereqUIsIte to obtammg the CertIficate of
Occupancy
<KRC> Understood.
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - PA
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON-ARCHITECT, P A
AA C001878
<East Bay> It is understood that the City will not require surety for installation
of the water and sewer utilities.
31 The LDR< Chapter 6, ArtIcle IV, SectIOn 16 reqUIres that all pomts on each
bUIldmg wIthm 200 feet of an eXIstmg or proposed fire hydrant. Please
demonstrate that the plan meets thIS condItIOn by showmg all hydrants ThIS
reqUIrement IS not satIsfied for the northeast comer of BUIldmg "F", the nuddle
of BUIldmg "B", or most of the Pubhx Supermarket.
<KRC> Revised Site Plan see Sheet A3 O.
<East Bay> The site development plans have been revised to provide the proper
fire protection (all building points shall be within 200 feet of an existing or
proposed fire hydrant).
32 PVC MatenalIs not perrmtted on the CIty'S water system. All hnes hall be DIP
<East Bay> The site development plans have been revised to indicate the use of
Dip on all water mains.
33 Appropnate backflow preventer(s) wIll be reqUIred on all commercIal water
servIce to the bUIldmgs, and the fire spnnkler hne If there are any, m accordance
WIth CODE Sec 26-207
<East Bay> The site development plans have been revised to indicate the
necessary backjlow preventers on all buildings. A note has also been added to
the Water & Wastewater Plan sheets that the devices shall conform to A WW A-
14 standards.
34 Why IS the eXIsting sanItary sewer run from Canterbury at Quantum VIllage
bemg reahgned? It wIll be less costly both m terms of money and time to retam
the eXIsting ahgnment. AddItIOnally no mterruptIOns of servIce would be
reqUIred to make the proposed change
<East Bay> The existing sanitary sewer from Canterbury is proposed to be
realigned to satisfy the landscaping requirement for the parking area terminus
landscape islands.
35 ProvIde nm and mvert elevations for all structures wIthm the subject parcel
<East Bay> The site development plans have been revised to indicate structure
rim and invert elevations.
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - P.A.
DESIGN
PLANNING'
INTERIORS
KENNETH R CARLSON -ARCHITECT, P A
AA C001878
36 Elumnate the dead-end fire hydrant run at the northeast comer of the property
That hydrant may be tapped/teed mto the water mam m High RIdge Road.
<KRC> See revised Site Plan on sheet A3.0 and revised civil dwgs.
<East Bay> Thefire hydrant located at the northeast corner of the property has
been revised to indicate the tap/tee on the water main in High Ridge Road.
37 Elumnate the dead-end fire hydrant run from the northwest comer ofBUIldmg
"A" to the northwest comer of Pubhx. Relocate hydrant to north of the aIsle
between bUIldmg "B" and Pubhx.
<KRC> See revised Site Plan on sheet A3. 0 and civil dwgs.
<East Bay> The fire hydrant located at the northwest corner of Publix has been
revised to the northwest of Building "A".
38 Elmnnate the dead-end hydrant run on the south side ofBUIldmg "F" Relocate
hydrant to the northwest comer of Buildmg "F" and tie mto the water mam on
the north side of BUIldmg "F"
<KRC> See revised Site Plan on sheet A3.0 and civil dwgs.
<East Bay> The fire hydrant located on the south side of Building "F" has
been revised to the north of Building "F"
39 Provide a ffilmmum of one swab msertIOn pomt for the proJect.
<East Bay> The site development plans have been revised to indicate the
installation of a permanent sample point on the proposed fire hydrant located
north of Building "F"
40 Provide a permanent samplmg station adjacent to the northeast comer of
Buildmg "F" or m the landscape Island north of that area.
41 Relocate water meter and fire Ime connectIOn at the rear of Pubhx to aVOId
conflIct With the proposed compactor
<KRC> See revised Site Plait on sheet A3.0 and civil dwgs.
<East Bay> The water meter and fire line connection at the rear of Publix is
only a representation of the area of connection to Publix. The meter, backflow
preventer and fire line will be constructed to avoid conflict with the proposed
compactor
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - PA
DESIGN
PLANNING.
INTERIORS
KENNETH R CARLSON - ARCHITECT P A
,
M C001878
42 Sheet 4 of 8 IS Incorrectly tItled "PaYmg & Dramage Plan" Correct to read
"Water & Wastewater Plan"
<East Bay> Sheet 4 of 8 on the site development plans have been revised
accordingly
43 Utlhty constructIOn detaIls wIll not be revIewed for constructIOn acceptabIhty at
tlus tlme All utlhty constructIOn detaIls shall be m accordance at thIS tlme All
utlhty constructIOn details shall be m accordance WIth the Utlhtles Department's
"Utilities Engineering Design handbook and Constructzon Standards" manual
(mc1udmg any updates), they wIll be revIewed at the tlme of constructIOn permIt
apphcatIOn.
<East Bay> It is noted that specific details will not be reviewed for construction
acceptability at this time.
Fire.
44 Pnor to FIre Department approyal of a bmldmg perrrut, new constructIOn must
provIde the results of a hydrant flow test mdIcatmg a fire flow not less than
1500gpm @ 20 pSI above domestlc use ThIS apphes to new or eXlstmg hydrants
wIthm the reqmred 200 feed of the faclhty
<East Bay> A fire hydrant flow test will be requested prior to building permit
submittal. Hydrant flow test of new hydrants within the required 200 feet of
the facility will be obtained prior to Fire Department approval.
45 Drawmg 4 of8 shows bmldmg "D" WIth a four (4) mch fire hne to the bldg.
WIth a DDC, but A3 0 says Bldg. "D" wIll not be spnklered. Smce the bldg IS
over 12000 square feet It must be spnnklered per CIty ordmance
sectIOn 9-6 3./ 7-11
<KRC> Revised "Site Tabulation Table" on sheet A3.0, Buildings A, B, E and
F shall be equipped with fire sprinkler system.
46 Drawmg 4 of 8 shows Bldg "A", "B", "E", and "F" WIth a four (4) mch fire hne
to the bmldmg With a DDC, but A3 0 mdlcates no spnnklers are bemg
1002 E Newport Center Drive Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - P.A.
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON - ARCHITECT P A
,
AA C001878
provIded. SInce these bUIldIngs exceed 30 feet In heIght, they must be
spnnklered per CIty sectIOn 9-6 3./7-11
<KRC> See revised "Site Tabulation Table" on sheet A3 0, Buildings A, B, E
and F shall be equipped with fire sprinkler system.
Police. NONE
Building Department.
47 IndIcate wIthm the SIte data the type of constructIOn of the/each bUIldIng as
defined In 2001 B\FBC, Chapter 6 IndIcate on the plan If the type of
constructIon IS protected or unprotected.
<KRC> See revised "Building Information" Table on sheet A3 O.
48 IndIcate WIthIn the SIte data the occupancy type of each bUIldIng as defined In
2-1 FBC, Chapter 3 Sheet a3 0 shows the buildIngs as "retaIl" and the SIte
InfOrmatIOn notes "M & F" Please clanfy
<KRC> See revised "Building Information" Table on sheet A3 O.
49 The heIght and area for bUIldIngs or structures of the dIfferent types of
constructIon shall be governed by the Intended use or occupancy of the bUIldIng,
and shall not exceed the hrmts set forth In Table 500 of 200 1 FBC
<KRC> See revised "Building Information Table" on sheet A3 O.
50 Place a note on the elevatIOn VIew draWIngs mdIcatmg that the extenor wall
opemngs and extenor wall constructIOn comply WIth 2001 FBC, Table 600
Subrmt calculatIOns that clearly reflect the percentage of protected and
unprotected wall opemngs perrmtted per 200 1 FBC, Table 600
<KRC> See revised sheets A5.0, A5.I, A5.2, A5.3 and A5 4
51 Every extenor wall wIthm 15 feet of a property hne shall be eqUIpped WIth
approved openIng protective per 2001 FBC, SectIOn 705 1 1.2
<KRC> No exterior walls within 15ft. of a property line.
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - PA
DESIGN
PLANNING'
INTERIORS
KENNETH R CARLSON - ARCHITECT, P A
AA C001878
52 General area modIficatIOns to bUIldIngs shall be In accordance wIth 2-0-1 FBAC,
SectIon 503 3, 503 3.2, and 503 3 3 ProvIde calculatIOns venfYIng complIance
wIth the above code sectIOn and 2001 FBC, Table 500
<KRC> See revised table on sheet A3 O.
53 BUIldIngs, structures and parts thereof shall be desIgned to wIthstand the
rmmmum wmd loads of 140 mph. WInd forces on every bUIldIng or structure
shall be detenruned by the prOVISIOns of ASCE 7, Chapter 6, and the prOVISIOns
of 200 1 FBC, SectIOn 1606 (Wind Loads) CalculatIOns that are sIgned and
sealed by a deSIgn professIOnal regIstered In the state of Flonda shall be
subrmtted for reVIew at the tIme ofpenrut applIcatIOn.
<KRC> See revised sheets A5.0, A5.I, A5.2, A5.3 and A5.4
54 At tImes of penrut reVIew, subrmt SIgned and sealed workIng draWIngs of the
proposed constructIOn.
<KRC> Singed and sealed working drawings of the proposed construction will
be submitted at times of perm it review
55 The accessible parkIng space/s that serve a use shall be located on the shortest
safety accessible route of travel from adjacent parkIng to an accessible entrance
The 2001 FBC states that bUIldIngs WIth multIple accessible entrances shall have
accessible parkIng spaces dIspersed and located closest to the accessible
entrance 2001 FBC, SectIOn 11-4 1.2(5),43, and 46
<KRC> Agree. See sheet A3.0.
56 Add a labeled symbol to the SIte plan draWIng that represents and delIneates the
path of travel for the accessible rout that IS between accessible parkIng spaces/s
and the accessible entrance door/s to each bUIldIng The Installed symbol,
reqUIred along the path, shall start at the accessible parkIng spaces/ and termInate
at the accessible entrance door/s to each bUIldIng The symbol shall represent
the locatIOn of the path of travel, not the locatIOn of the detectable warnmg or
other pavement markIngs. The locatIon of the accessible path shall not compel
the user to travel In a dnve/lane area that IS located behInd parked vehIcles
IdentIfy on the plan the WIdth of the accessible route (Note The mmImum
clear WIdth of an accessible route shall be 36 Inches, except at curb ramps that art
part of a reqUIred means of egress shall be less than 44 Inches) Add text to the
1002 E Newport Center Drive, Suite 101 Deerfield Beach FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www kencarlson.com
KENNETH
CARLSON
ARCHITECT - P.A.
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON - ARCHITECT, P A
AA C001878
drawIng that would IndIcate that the symbol represents the accessible route and
the route IS desIgned In complIance wIth 2001 FBAC, SectIOn 11-4 3
(Accessible Route) and 11-46 (ParkIng and Passenger LoadIng Zones) Please
note that at tIme ofpenrut reVIew, the applIcant shall provIde detaIled
documentatIOn on to plans that wIll venfy that the accessible route IS In
complIance WIth the regulatIOns specIfied In the 2001 FBC ThIS document shall
Include, but not be lumted to, provIdIng fimsh grade elevatIOn along the path of
travel Show the wIdth of the accessible route for all the bUIldIngs
<KRC> Revised, see sheet A3. O.
57 Add to the subrmttal a partIal elevatIOn VIew draWIng of the proposed penmeter
wall IdentIfy the type of wall matenal and the type of matenal that supports the
wall, IncludIng the typIcal dIstance between supports. Also, provIde a typIcal
sectIOn VIew draWIng of the wall that Includes the depth that the wall supports
are below fimsh grade and the heIght that the wallIS above fimsh grade The
locatIon and heIght of the wall shall comply WIth the wall regulatIOns specIfied
In ZonIng Code
<KRC> Revised, see sheet A3. O.
58 IndIcate on the floor plan draWIngs WIthIn the footpnnt of the bUIldIng the
pnmary use of the bUIldIng. Sheet A3 0 notes "M&B" What IS thIS? The
BUIldIngs are noted as retaIl Please clanfy
<KRC> See revised "Site Tabulation" Table on sheet A3. O.
59 As reqUIred by LDR< Chapter 4, SectIOn 7, subrmt a current survey of the
subject property
<East Bay> See attached survey.
60 CBBCPP 3 C.3 4 reqUIres the conservatIon of potable water CIty water may
not, therefore, be used for landscape ImgatIon where other sources are readIly
aVailable
<East Bay> Potable water will not be used for irrigation. Irrigation water will
be supplied by separate wells.
<LDS>
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - PA
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON - ARCHITECT, P A
AA C001878
61 A water-use perrrut from SFWMD IS reqUIred for an ImgatIon system that
utIlIzed water from a well or body of water as It source A copy of the permIt
shall be subInltted at the tIme ofperrrut applIcatIon, F S 373.216
<East Bay> A water-use permit from SFWMD for the irrigation system will be
obtained prior to the time of building permit application.
62 If capItal faCIlIty fees (water and sewer) are paid m advance to the CIty of
Boynton Beach UtilItIes Department, the followmg mformatIOn shall be proVIded
at the tIme ofbUIldmg perrrut applIcatIOn
a) The full name of the project as It appears on the Development Order and
the ComnnssIon-approves SIte plan.
b) The total amount paId and IteInlzed mto how much IS for water and how
much IS for sewer (CBBCO, Chapter 26, ArtIcle II, SectIOn 26-34)
<East Bay> It is understood that if capital water and sewer facility fees are paid
in advance to utilities, then the necessary information will be provided at the
time of building permit application.
63 At tIme of penrut reVIew, provIde a completed and executed CBB Umty of TItle
form. The form shall describe all lots, parcels or tracts combmed as one lot. A
copy of the recorded deed WIth legal descnptIOns, of each property that IS bemg
umfied, IS reqUIred to be submItted to process the form. The property owner that
IS IdentIfied on each deed shall match.
<East Bay> It is understood that if capital water and sewer facility fees are paid in
advance to utilities, then the necessary information will be provided at the time of
building permit application.
64 Add a general note to the SIte plan that all plans subInltted for penruttmg shall
meet the CIty'S codes and applIcable bUIldmg codes m effect at the tIme of
perrrut applIcatIOn.
<KRC> See revised notes on sheet A3 O.
65 Pursuant to approval by the CIty CormmssIOn and all other outsIde agencIes, the
plans for thIS project must be submItted to the BUIldmg DIVISIon for reYIeW at the
tIme of perrrut applIcatIOn submIttal The plans must mcorporate all the
condItIons of approval as lIsted m the development order and approved by the
CommISSIOn.
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - PA
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON - ARCHITECT P A
. ,
AA C001878
<KRC> Agree.
66 Sheet 2 of 8 - The 2' car overhang for BUIldmg "D"" appears to be mfnngmg on
the reqUIred handIcap accessible route The nummum wIdth shall be 36" except
at curb ramps that art part of a reqUIred means of egress shall not be less than
44" 2001 FBC 11-4 3 3
<KRC> Revised sidewalk width to 6'- 0" with 2' - 0" car overhang See sheet
A3 O.
67 Clearly show the accessIble route for BUIldmgs "E" and "F" as reqUIred by
SectIOn 11-4 1.2(1) and 1-43 of the 2001 FBC
<KRC> See revised Site Plan on sheet A3.0.
68 Sheet 2 of 8 -Retail BUIldmg "F"-Plans note the square footage as 6,550 sq ft.
and also 13,100 sq Ft. Please clanfy SectIOn 104.2 1 of the Boynton Beach
Amendments to the 2001 FBC Note the square footage of each floor and of the
bUIldmg.
<KRC> See revised Site Plan on sheet A3.0 and revised drawings on sheet A4.4
69 Sheet 3 of 8 - BUIldmg "c" (PublIx) -The deSIgn of the accessIble parkmg
spaces do not comply WIth the 2001 FBC A person In a wheelchaIr or other
mobIlIty aid would not have access to the accessible route crossmg WIthout
walkmg or wheelIng behmd parked vehIcles The mmImum WIdth of the
accessible route shall be 44" per sectIOn 11-4 6.2( 1) of the 200f FBC
<KRC> See revised accessible parking spaces on sheet A3.0
70 Subnut details for the wood trellIs located on the south SIde ofBUIldmg "c"
(PublIx) per SectIon 104 2 1 of the Boynton, Beach AdnumstratIve Amendments
to the 2001 Flonda BUIldmg Code
<KRC> See provided partial trellis elevation on sheet A3 2.
71 Clearly show the WIdth of the paver walk located m front of the mam entrance to
BUIldmg "C (PublIx) The WIdth of the paver walk shall comply WIth SectIOn
11-43 3 of the 2001 FBC
<KRC> See revised site plan on sheet A3 O.
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - P.A.
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON - ARCHITECT, P A
AA C001878
72 Sheet 3 of 8 - SubmIt detaIls of the "retammg anchor block wall" located east of
the parkmg lot for Bmldmg "B" SectIOn 104.2 1 of the Boynton Beach
AdmInIstratIve Amendments to the 2001 FBC (see also Sheet A3 0)
<KRC> Anchor block wall detail #7 provided on sheet A3.2.
73 The 2' car overhang appears to be mfnngmg on the accessIble route for bUIldmg
"B" Comply wIth SectIOn, 11-4 3 3 for the WIdth of the accessible route
Passmg space shall be provIded per sectIOn 11-4 3 4 of the 2001 FBC
<KRC> Sidewalk width increased to 6' - 0" with 2' - 0" car overhang, see
sheet A3 O.
74 Sheet A3 0 - IdentIfy the Pubhx bUIldmg as BUIldmg as BUIldmg "c" on the
plans SectIOn 1 04.2 1 of the Boynton Beach Amendments to the 2001 FBC
<KRC> See revised site plan on sheet A3 O.
75 Sheet A3 1 - DetaIl # 1 - Detectable warnmg surfaces shall comply wIth SectIOn
11-4.29.2(1)(2) of the 2001 FBC Grooves may be used mSIde only
<KRC> See revised detail #1 on sheet A3.I.
76 Sheet A3 1 - Clearly show the mtenor dImenSIOns of the dumpster enclosure
The MInImUm SIze shall be 10 feet x 10 feet clear
<KRC> See revised detail #2 on sheet A3.1
77 All bUIldmgs that are m excess of 12,000 square feet per floor shall be provIded
wIth an approved automatIc fire spnnkler system per SectIOn 9-6 of the CIty of
Boynton, Beach Code of Ordmances (see bUIldmg "D")
<KRC> See revised "Site Tabulation Table" on sheet A3 O.
78 Sheet SL-l - lIght poles shall be deSIgned to comply wIth SectIon 1606 of the
2001 FBC for 140 mph wmd load.
<KRC> See note provided on sheet SL1
79 Extenor walls shall have access openIngs for fire department use servmg each
story above grade on an accessible SIde of the bUIldmg up to a heIght of75 feet.
SectIon 1405 1 of the 2001 FBC (see bmldmg "F")
<KRC> Two fire dept. access windows provided. See sheet AS 4
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - PA
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON - ARCHITECT, P A
AA C001878
Parks and Recreation. NONE
Forester/ Environmentalist:
80 The apphcant must mdIcate on a landscape plan the eXIstmg trees/vegetation that
WIll be preserved, relocated, and removed/replaced on the sIte A separate
symbol should be used on the landscape plan to Identify these trees/ vegetatIOn.
<LDS> Once a tree survey is supplied consideration will be given.
81 All shade and palm trees on the Plant Schedule must be lIsted m the
specIficatIOns as a rmmmum of 12-14 feet m heIght, three (3) mches m calIper at
DBH (4.5 feet off the ground), and Flonda #1 (Flonda grades and Standards
manual) ThIS mcludes multI-trunk specIes The heIght of the trees may be
larger than 12-14 feet to meet the 3 mch calIper reqUIrement. (EnvIronmental
Regulauons, Chapter 7 5, ArtIcle II Sec 5 c.2 )
<LDS> All trees & palms are specified as noted on the plant schedule. A note
was also added stating that size of the tree may be larger than specified to meet
the 3" caliper at D.B.H. as shown on the detail.
82 The landscape deSIgn shown Identify the CIty sIgnature trees (Tibochma
granulose) as the project mgress / egress locations [EnvIronmental RegulatIOns,
Chapter 7.5, Article II Sec 5 C N ]
<LDS> The Tibouchina was used at the project's entries as requested.
83 The DetaIls sheet section on thIS page should mclude a lIne mdIcatmg where the
heIght of the large tree and palm tree and the calIper @ DBH wIll be measured at
time of plantmg and mspectIOn.
<LDS> The detail sheet reflects the height & caliper measurement as noted.
84 The applIcant should show the calculated 50% native speCIes of trees, shrubs and
ground cover plants
<LDS> The vegetation is broken down as to whether they are native species
with the 50% requirement being met.
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT ~ PA
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON - ARCHITECT, P A
AA C001878
85 The applIcant should add a note that all utIlIty boxes or structures (not currently
known or shown on the plan) should be screened WIth Cocoplum hedge plants on
three SIdes
<LDS> A note was added to the landscape plan as per the comment.
86 The applIcant should add a note that no Cypress mulch can be used on the SIte
<LDS> A note was added to the detail sheet at the plant schedule as per the
comment.
IrrIgatIOn Plan
87 There IS no ImgatIOn system deSIgn mcluded WIth the SIte plan. The ImgatIOn
deSIgn should be low-flow for water conservatIOn. All shade and palm trees
should receIve ImgatIOn from a bubbler source [EnVIronmental RegulatIons,
Chapter 7 5, ArtIcle II Sec 5A.]
<LDS> The system will be designed as noted.
88 Turf areas should be lIrruted m SIze Landscape (beddmg plants) areas should be
deSIgned on separate zones WIth proper tIme duratIOn for water conservatIOn.
[EnVIronmental RegulatIOns, Chapter 7 5, ArtIcle II Sect. 5 C 2 1]
<LDS> The system will be designed as noted.
Plannin2 and Zonin2.
89 PrOVIde a colored rendenng of all four (4) elevatIOns (ClIpped, not glued) at the
TechnIcal ReVIew COmmIttee meetmg.
<KRC> Colored rendering of all four elevations (clipped) will be provided at
the Technical Review Committee Meeting
90 PrOVIde pamt swatches WIth manufacturer name, color name and a number at the
TechnIcal ReVIew COmmIttee meetmg.
<KRC> Paint swatches with manufacturer name, color name and a number
will be provided at the Technical Review Committee meeting
91 All sIgnage must be approved concurrent WIth the SIte Plan subrruttal or an
addItIonal reVIew by Staff, Board and CIty CommIssIOn wIll be reqUIred solely
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - P.A.
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON - ARCHITECT, P A
AA C001878
for the sIgnage ProvIde font SIze, style and color as well as calculatIOns of
square footage of proposed, typIcal wall sIgnage
<KRC> Typical wall sign detail #5 provide on sheet A3.2.
92 A sIngle SIgn style (such as cabmet, channel, reverse channel) shall be used for
wall sIgnage on all bmldmgs on a SIte
<KRC> Typical wall sign detail #5 provide on sheet A3.2.
93 The base of a monument SIgn shall be enhanced WIth colorful ground cover plant
matenal and a nnmmum of two (2) colorful shrub speCIes
<KRC> Monument sign detail #6 provided on sheet A3.2.
94 All proposed monument SIgnS shall clearly mdIcate the project street access
<KRC> Agree, see site plan.
95 A letter of approval from Palm Beach County Traffic Engmeenng DIVISIOn
regardmg the subnnttal of a traffic statement wIll be reqmred pnor to Issumg a
perrmt for thIS proJect.
<KRC> We understand and agree.
<East Bay> A letter of approval from PBe Traffic Engineering regarding the
submittal of a traffic statement will be submitted prior to building permit
approval.
96 The detaIl of the typIcal freestandmg outdoor hghtmg fixture should mclude the
oyerall heIght, extenor fimsh and color(s) The deSIgn, style, and IllummatIOn
level shall be compatible WIth the bmldmg deSIgn (heIght and style) and shall
conSIder safety, functIon and aesthetIc yalue
<KRC> Detail provided. See revised sheet SLI
97 Rooftops WIll be treated as part of the bmldmg elevatIOns All rooftop
eqmpment must be completely screened from VieW at a rmmmum dIstance of 600
feet.
<KRC> See revised sheets A5.0- A5 4 All rooftop equipment will be completely
screened from view at minimum distance of 600 feet by parapet walls.
98 Recommended that the mtemal parkmg lot crosswalk be of a paver bnck deSIgn.
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - P.A.
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON - ARCHITECT, P A
AA C001878
<KRC> See revised site plan for paver pattern stamped concrete crosswalks on
sheet A3 O.
99 FIfty percent (50%) of all sIte landscape materIal must be natIve speCIes On the
landscape plan plant lIst mdlcate the natIve speCIes by trees, shrubs and
groundcover and tabulate the amount of natIve materIal m each category to
ensure each meets the 50% reqUIrement.
<LDS> The vegetation is broken down as to whether they are native species
with the 50% requirement being met.
100 All reqUIred trees shall be a rmmmum 12 feet and 3 mch calIper (DBH) at
tIme of plantmg
<LDS> All trees & palms are specified as noted on the plant schedule. A note
was also added stating that size of the tree may be larger than specified to
meet the 3" caliper at D.B.H. as shown on the detail.
101 Remove small accent trees from tree category and place under shrubs If they
are not mtended to meet 12 foot heIght reqUIrement. Ensure that total tree count
does not fall below the number reqUIred.
<LDS> The small trees were removed from the tree category and put into the
shrub category as requested.
102 Concrete curb and landscape the stnped:-out Islands along the west entry
drIve
<KRC> Concrete curb and landscape island is provided along west entry
drive. See revised site plan on sheet A3.0.
<East Bay> The southern most striped-out island along the west entry drive
has been revised on the site development plan to include concrete curbing
and landscaping.
<LDS> Landscaping was added with the change as noted.
103 The grass medIans depIcted on A3 0 should be landscaped WIth low, colorful
shrubs that do not mterfere WIth motorIst YlsibIlIty
<LDS> Unsure ofwhere this falls in relationship to landscape plans.
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - PA
DESIGN
PLANNING.
INTERIORS
KENNETH R CARLSON - ARCHITECT, P A
AA C001878
104 ModIfy the penmeter plantmg scheme to utIlIze clustenng/serpentme
technIques as opposed to straIght hne plantmg.
<LDS> The perimeter planting was modified to reflect this request.
105 ReqUIred landscape buffer adjacent to nghts-of-way shall contam two layers
of plant matenal The first layer shall be a combmatIOn of colorful groundcover
plants and a mInImum of two colorful shrub speCIes The next layer shall
consIst of a contmuous hedge and one tree spaced a maXImum of 30 feet apart.
The hedge (2nd layer) shall be a mInImum of24 mches m heIght, 24 mches of
spread and planted tIp-to tIp
<LDS>The buffer planting was modified to reflect this request.
106 ConsIder denser plantmg scheme around dumpster at SW comer of the SIte
and m the first 90 feet runnIng north of the dumpster (along the west property
lme) to better screen thIS area and the back of BUIldmg "D" from eastbound
traffi c
<LDS> The design was modified to provide screening as noted.
107 ConsIder Plantmg SpanIsh Stopper (proposed m front of the screen wall) at a
heIght between 3\6 - 48 mches.
<LDS> The height of the Stopper was increased as noted.
108 Decrease the spacmg on the BougamvIllea along the wooden trellIs to mclude
a plant at each post/column.
<LDS> The spacing of the Bougainvillea was decreased as noted.
109 ConsIder screen wall connectmg rear ofbUIldmg "A" and "B" and create
more of a lush courtyard settmg between the bUIldmg for outdoor seatmg/dmmg.
<KRC> Screen wall provided. See revised site plan on sheet A3 O.
<LDS> The screen wall was added and the landscape was designed to reflect
the comment.
110 Recommend the use of MedJool Palms at key focal pomts and entry pomts
<LDS> Medjool Palms were used at the key focal points and entries as noted.
1002 E Newport Center Drive Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - P.A.
DESIGN
PLANNING.
INTERIORS
KENNETH R CARLSON - ARCHITECT, P A
AA C001878
III Ensure specIes counts In Plant LIst match the number depIcted on the plan
Itself.
<LDS> The species count on the landscape plan matches the plant list as
requested.
112 ConsIder constructIOn of a second pavlhon along the north property lme m
ahgnment wIth the central north/south dnve aisle to termmate that VIsta.
<KRC> We have provided additional trellis at that location. See revised site
plan on sheet A3. 0
113 PrOVIde fimsh schedule of the pavlhon and screen wall on page A3 2
<KRC> Finish schedule provided on sheet A3.2.
114 The detaIl prOVIde on the pavlhon appears to have a standmg seam metal roof
m contrast to the s-tIle roofing throughout the SIte
<KRC> Yes, encourage change ofmaterial.
115 PrOVIde detaIl drawmg and fimsh schedule on gazebo at SE comer of
property
<KRC> Detail #4 provided. See revised sheet A3.2.
116 The bus stop IS not prOVIded WIth a matchmg pavlhon/gazebo structure to
those located elsewhere on the SIte ThIS area should be mcely landscaped as
well
<KRC> Client will communicate with Palm Tran to purchase standard
design bus stop feature that relates to the project design.
117 ReView parkmg counts on page A3 0 It would appear as though there are
408 regular spaces and 16 HlC spaces.
<KRC> See revised "Parking Tabulation Table" 01'1 sheet A3 O.
118 Llghtmg shall not be of an mtenslty that produces glare on adjacent
propertIes Llghtmg shall not be used as a form of advertlsmg m a manner that
draws more attentIOn at mght than dunng the day The areas abuttmg the
resIdential to the north appears to exceed code reqUirements AddItIOnally, It IS
1002 E Newport Center Drive. Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
KENNETH
CARLSON
ARCHITECT - PA
DESIGN
PLANNING-
INTERIORS
KENNETH R CARLSON - ARCHITECT, P A
AA C001878
recommended that decoratIve IIghtmg fixtures, like those proposed on the
bUIldmgs, be used m the parkIng lot.
<KRC> See revised sheet SLl
119 ConsIder consultatIon wIth Margelly Beltran, the CIty'S Urban DeSIgner
(561) 742-6263 regardmg addItIonal Improvements to the south elevatIOn of
BUIldmg "F"
120 ProvIde a letter of approval from the Quantum Park ArchItectural ReVIew
comnnttee (ARC) pnor to TRC meetmg
<Client> Please find attached letter of approval.
121 The SIte plan mdIcates two SIgnS at each of the two entrances off of Gateway
Boulevard. The SubdIVISIOn Master Plan shows, and the code only allows one
at each entrance
<KRC> See revised site plan on sheet A3.0. Only one monument sign per
entrance provided.
122 The SubdIVISIOn Master Plan was approved WIth SIX reSIdentIal umts that do
not appear on tlns subtmttal.
<KRC> Client would like to omit residential units from this project.
123 The "Request For WaIvers" noted on page A3 1 do not match those of the
approved SubdIVISIOn Master Plan.
<KRC> The "Request for Waivers" revised, see sheet A3.1
124 ProvIde an analYSIS on warrants for a traffic SIgnal on HIgh RIdge Road at the
entrance/ eXIt to the property, based on thIS ImmedIate proJect, the approved
reSIdential to the north and Tn RaIl operatIOns to the east. EXIstmg and
prOjected traffic volumes, stackmg/quemg, turmng movements and the field of
VISIOn assOCIated WIth the curvature of the road may warrant the SIgnal.
1002 E Newport Center Drive, Suite 101 Deerfield Beach, FL 33442 Phone (954) 427-8848 Fax (954) 427-9929 www.kencarlson.com
1'":_:.-.. ----.-~------~----
~ r",
- . - --~__.D
-~-- i
Architedural .Review Committee I '
Quantum Park Property Owners' Association.. Inc~
2500 Quantum lakes DrIve, Suite 100
Boynton Beach, fL 33426
FfP
1anwuy 27~ 2004
Kenneth R Carlson - Archttect, P.A.
1002 E. Newport Center Dnve
Suite 101
Deerfield Beach, FL 33442
RE. Quantum Pubbx. P/O' Lots 83 - 85
Architectural Review Commrttee
Dear Mr Carlson.
On 1anuary 20, 2004 the Archttectwal RevIew CommIttee met and approved the plans for
Quantum PublIx as submitted
The followmg Itst mdicates submItted matena1.
· East Bay Group. LLC~ Paving and Dramage PIan. dated 01108/03, Sheet 2 and 3
of8
· East Bay Group, LLC, Water and Wastewater PIan. dated 01108/03, Sheet 4 and 5
of8
· East Bay Group~ LLC, Pavmg and Dramaee Details~ dated 01/08104, Sheet 6 of 8
· East Bay Group, LLC, Water Details, dated 01108I04~ Sheet 7 of8
· East Bay Group, LLC, Wastewater Details, dated 01108104, Sheet 80f8
· Land DesIgn South, Landscape Plan. ReviSIon Date 01/15104, Sheet LI and L2
· Land Design South., Landscape Detail, RevISion Date 01115/04, Sheet L3
· Timothy M. Smtth Land Surveymg, Inc., Boundary and Topographtcal Smvey,
dated February 2003, Sheet 1 of 1
· Kenneth R Carlson - ArcIntect, P_A., SIte Plan, ReviSion Date 10/30/03, Sheet
AJO
· Kenneth R Carlson - Arclutect, P.A~ Parkmg Detail, Sign Detail, Dumpster
Detail, Request for W~ General Notes, Revmoo Date 10130103, Sheet A3 1
.JCennetJt R Carlson - ArcIntect, P A~ - PavilIon Details, Screen Wall ~
Partial Trelhs Elevatron, Gazebo Elevations, Anchor Block Wall Details, Wall
Sl~ Monmnent Sign DeWI, FinIsh Schedule, RevISion Date 10130103, Sheet
A3.2
· Kenneth R Carlson - Architect, P A, Floor Plan Retail Buildings A & B, Dated
10120/03, Sheet A4.0
· Kenneth R Carlson - ArcIntect, P A, Floor Plan - Pubhx, Dated 10120103, Sheet
A4.1
Os ~~~~
Kemteth R Carlson - Arclntect, P A
Ianwuy 27~ 2004
Page Two
· Kenneth R Carlson - Architect, P.A~ Floor Plan - Retail BuiJdingD~ Dated
10120/03" Sheet A4.2
. Kenneth R Carlson - Archttect, P.A.. Floor Plan - Building E. Dated IOflO/03.
Sheet A4.3
· KeonethR. Carlson - ArcIutect, P.^-. First Floor Plan - Building F. Dated
10120/03. SheetA4.4
· Kenneth R Carlson - ArchItect, P.^-. Elevations BuildIngs A and B. RevISIon
Date 10130103. Sheet A5 0
· Kenneth R Carlson - Architect:, P.^-~ Elevations Publtx, RevISIOn Date 10130103.
Sheet A5 1
· Kenneth R Carlson - ArcIntect, P A. Elevations Buildmg D. RevISIon Date
10/30/03. Sheet M.2
· Kenneth R Carlson - ArcIutect, P.A. ElevatIons BuildIng E. RevlSlon Date
10130103. Sheet AS.3
· Kenneth R Carlson - Archttect, P.A. ElevatIons Buildmgs F. ReviSIon Date
10130103. Sheet AS 4
· Kenneth R Carlson - Archrtect, P A. Site Llghtmg Plan, ReVISIon Date 10130103.
Sheet SL 1
· Kenneth R Carlson - ArcIutect, P.A. Colored Elevations Buildings A and B.
Dated 10/10103. Sheet M 0
· Kenneth RCarlson - Architect, P A. Colored ElevatJ.ons Building E. Dated
10/13103. Sheet AS 0
· Kenneth R Carlson - Archrtect, P A. Colored Elevations BuiIdmg C - PublIX,
Dated 10/13/03. Sheet A5 0
· Kenneth R Carlson - Archrtect, P.A. Colored Elevations Buildmg F. Dated
10/13103. Sheet AS 0
· Kenneth R Carlson - Arclntect, P.^-. Colored Elevations Buildmg D. Dated
10/13103. SheetM.O
If you have any questions regardmg the above. please feel free to contact our office.
Smcerely.
,
~ J--rJ?dJ
lube Finch
C:QPOAlARClAppcv ltRIlct 18&19 012703.doc
KENNETH
CARLSON
ARCHITECT - PA
----~----_..--,-_.__.,.-.-
DESIGN
PLANNING,
INTERIORS
KENNETH R CARLSON - A_BCHITE9T, P A
AA C001878
November 6, 2003
CIty of Boynton Beach
Attn. Plannmg Department
100 East Boynton Beach Blvd.
Boynton Beach, FL 33425
RE Payment for Quantum VIllage North - publIx
To Whom It May Concern
Enclosed please find check #8846 m the amount of$750 00 to be applIed
towards the account for Quantum PublIx. If you have any questIons, please feel free
to call me at (954) 427-8848
Best regards,
SM-1/L
Sue Neff ~\~d
AdmInIstrator/Bookkeeper
NOV I 2 am
SN/nsv
Enclosure