Loading...
AGENDA DOCUMENTS AGENDA DOCUMENTS ({( CITY OF BOYNTON BEACH AGENDA ITEM REQUEST FORM Requested City Commission Date Final Form Must be Turned Requested City Commission Date Final Form Must be Turned Meetim! Dates in to City Clerk's Office Meeting Dates in to City Clerk's Office 0 April 4, 2006 March 20, 2006 (Noon.) 0 June 6, 2006 May 15,2006 (Noon) ~ April 18, 2006 April 3,2006 (Noon) 0 June 20, 2006 June 5 2006 (Noon) 0 May 2, 2006 April 17 2006 (Noon) 0 July 5, 2006 June 19 2006 (Noon) 0 May 16, 2006 May I 2006 (Noon) 0 July 18, 2006 July 3 2006 (Noon) 0 AdministratIve 0 Development Plans NATURE OF 0 Consent Agenda 0 New Business AGENDA ITEM IZI Public Hearing 0 Legal 0 Bids 0 UnfInished Business 0 Announcement 0 Presentation 0 City Manager's Report RECOMMENDATION Please place this request on the April 18, 2006 City Commission Agenda under Public Hearing. The Planning and Development Board recommended that the subject request be approved on March 28, 2006, subject to staff comments. For further details pertaining to the request, see attached Department Memorandum No 06-058. EXPLANATION PROJECT AGENT OWNER. LOCATION DESCRIPTION Quantum Park & Village South Commercial (MPMD 06-001) Eugene Gerlica Quantum Park & Village, LLC Southwest comer of Gateway Boulevard and High Ridge Road Request for a Master site plan modification approval to construct an additional 129 dwelling units (for total of363 dwelling units), 18,768 square feet of office, 23,262 square feet of retail, and 39,722 square feet of restaurant on a 26.17-acre parcel on a Mixed-Use (MU) pod in the Planned Industrial Development (Pill) zoning district. PROGRAM IMPACT N/A FISCAL IMPACT N/A ALTERNATIVES: ~. /J~A Devel~~{ City Manag""s Signa""e p~~ ~irecto, City Attorney I Finance I Human Reso""es S:\Planning\SHARED\WP\PROJECTS\Quantum Park & Village\SBMP 02-001 south\MPMD 06-001 \Agenda Item Request Quantum Pk & Village S. Comm MPMD 06-001 4-18-06.dot S'\BULLETIN\FORMS\AGENDA ITEM REQUEST FORM.DOC DEVELOPMENT DEPARTMENT MEMORANDUM NO. PZ 06-058 TO' Chairman and Members Planning and Development Board FROM Michael W Rumpf Director of Planning & Zoning Eric Lee Johnson, AICP ~ Planner (j March 22, 2006 THROUGH DATE. SUBJECT Quantum Park & Village South - File No MPMD 06-001 Master Site Plan Modification PROJECT NAME: Quantum Park a. Village South MPMD 06-001 LOCATION. Generally located approximately 165 feet west of the southwest corner of Gateway Boulevard and High Ridge Road (see Exhibit "A" - Location Map) LAND USE Quantum Park DR! Master Plan Land Use is Mixed Use - MU ZONING: Planned Industrial Development (PID) NATURE OF REQUEST Mr Eugene A. Gerlica, P .E. of Quantum Group of Companies is requesting to modify the master site plan for Quantum Park & Village South. This development is generally located approximately 165 feet west of the southwest corner of Gateway Boulevard and High Ridge Road (see Exhibit "A" - Location Map) The specific request is to construct a total of 129 dwelling units, distributed amongst a five (5)-story condominium building (at approximately 65 feet in height), three (3) mixed-use buildings, and a two (2)-story apartment building The project also proposes 18,768 square feet of office, 23,262 square feet of retail, and 39,722 square feet of restaurant on the 14.265-acre parcel, all of which are proposed within the commercial "portion" of the master site plan This would result in a total of 363 dwelling units for the entire master site plan BACKGROUND/ ANALYSIS On September 3, 2002, a master site plan was approved for 234 rental apartments and 132,032 square feet of commercial on 26 17 acres. This master site plan is known as Quantum Park & Village South (SBMP 02-001) Master site plan approval is valid indefinitely per Chapter 2, Section 7 P 9 of the Land Development Regulations. The master site plan was also approved with six (6) waivers. These waivers are itemized on the tabular data The Quantum Park & Village South master site plan is comprised of two (2) technical site plans, namely Quantum Park & Village South Residential (NWSP 02-022) and Quantum Park & Village South Commercial (NWSP 03-004) Technical site plans on mixed use Pods within Planned Industrial Developments do not require City Commission review and approval, provided that they are found to be consistent with the master site plan. The "residential" component of the master site plan was developed as the third phase of the Villas Memorandum No PZ 06-058 Quantum Park & Village South Master Site Plan, MPMD 06-001 Page 2 at Quantum Lakes project. The "commercial" technical site plan for Quantum Park & Village South (NWSP 03- 004) was approved with six (6) buildings totaling 119,185 square feet of commercial area Both the "residential" (NWSP 02-022) and "commercial" (NWSP 03-004) technical site plans were found to be consistent with the master site plan (SBMP 02-001), and were therefore approved administratively by staff However, no permits were ever secured for the "commercial" technical site plan On July 19, 2005, the 14.265-acre site "commercial" technical site plan was approved for a major modification (MSPM 05-003) that proposed less commercial area in favor of constructing residential dwelling units. The major site plan modification was approved for 71,708 square feet of commercial space, several mixed-use buildings, a two (2)-story apartment building, and a four (4)-story condominium building A master site plan modification (MPMD 05-008) was simultaneously reviewed and approved for the conversion of commercial space to additional dwelling units. Meanwhile, the developer subsequently submitted a request for code review (CDRV 05-006) to change the Land Development Regulations regarding the maximum height allowed for buildings that are located on mixed use Pods in Quantum Park. On July 5, 2005, pursuant to Ordinance 05-023, buildings on mixed use Pods are allowed to be up to five (5)-stories tall and 75 feet in height, but only as conditional uses. At this time, the applicant is again seeking to modify the "commercial" technical site plan in order to add a fifth floor to the condominium building This would result in a structure height of approximately 65 feet. Basically, the buildings and parking areas are depicted in the same configuration as the previously approved site plan, except that a fifth floor is proposed to be added to the condominium building and the commercial square footage is allocated specifically for office, retail, and restaurant uses. However, these additional dwelling units represent a significant change to the "commercial" technical site plan and likewise, to the approved master site plan Therefore, approval of this master site plan modification is contingent upon the approval of the accompanying request for conditional use approval (see Exhibit "C" - Conditions of Approval) It should be noted that the proposed changes to the "commercial" portion of the master site plan do not impact any of the approved waivers. As previously mentioned, the Quantum Park & Village South master site plan is comprised of two (2) components, namely, the "residential" component and the "commercial" component. The master site plan tabular data originally showed the parking requirements as follows. Commercial 71,708 square feet @ 1/225 One bedroom 143 units @ 1.5 spaces Two bedrooms 206 units @ 2 spaces 5% guest spaces for Villas at Quantum Lakes 319 spaces 215 spaces 412 spaces 19 soaces 965 spaces The above referenced list indicated that 965 parking spaces were required The master site plan provided a total of 1037 parking spaces, or an excess of 72 parking spaces. However, the applicant is now proposing to utilize the Urban Land Institute's (UU) methodology for shared parking Under the UU, the commercial component's required parking is as follows Office 18,768 square feet = 9 spaces (UU) Retail 23,262 square feet = 104 spaces (UU) Restaurant: 39,722 square feet = 177 spaces (UU) Residential- 1 bedroom 15 units @ 1 5 space per unit = 23 spaces (UU) Residential- 2 bedroom 114 units @ 2 spaces per unit = 228 spaces (UU) 541 spaces Memorandum No PZ 06-058 Quantum Park & Village South Master Site Plan, MPMD 06-001 Page 3 Therefore, the "commercial" portion of the master site plan would require a total of 541 parking spaces based on day and peak hour analysis. It should be noted that the "residential" component (Villas at Quantum Lakes) was previously approved for 234 dwelling units and should be considered as part of the master site plan tabular data These 234 dwelling units were not included within the above referenced UU calculations. In conclusion, the Quantum Park & Village South master site plan requires and provides the following parking Office Retail Restaurant: Residential- 1 bedroom Residential- 2 bedroom Residential- 1 bedroom Residential- 2 bedroom Guest spaces 18,768 square feet 23,262 square feet 39,722 square feet 15 units @ 1.5 space per unit 114 units @ 2 spaces per unit 130 units @ 1.5 space per unit 104 units @ 1 75 space per unit 5% guest spaces 9 spaces (UU) 104 spaces (UU) 177 spaces (UU) 23 spaces (UU) 228 spaces (UU) 195 spaces Villas at Quantum Lakes 182 spaces Villas at Quantum Lakes* 19 spaces Villas at Quantum Lakes Total spaces Required Total spaces Provided Net difference 937 spaces 1011 spaces + 74 spaces * The ratio for 1 75 parking spaces per unit was approved per Site Plan Waiver (SPWV 03-001) on June 3, 2003 A surface water management system has served the Quantum Community Development District since 1989 The District has legal positive outfall to the Lake Worth Drainage District's E-4 Canal The stormwater runoff is discharged via an existing control structure. The proposed volume and rate of the discharge would be controlled pursuant to the applicable permits. The subject property would connect to the existing District system The Engineering Division of Public Works reviewed the drainage plans to ensure compliance with all applicable codes and regulations regarding legal positive outfall The conceptual plans submitted herein, are acceptable to the Engineering Division but as per staff policy, a more detailed version would be required at the time of permitting (see Exhibit "c" - Conditions of Approval) The master site plan's original traffic impact study was approved by the Traffic Division of Palm Beach County on June 28, 2002. The master site plan was approved for 234 multi-family dwelling units, 82,260 square feet of general retail, and 32,010 square feet of office. A revised study approved on August 19, 2002 included 136 multi-family dwelling units and 102,235 square feet of general retail In February of 2005, Ordinance 05-013 for Development of Regional Impact (DRIA 05-001) was approved by the City Commission to increase the maximum number of dwelling units allowable with Mixed Use Pods (within the entire Quantum Park DR!) from 1,000 units to 1,105 units. These additional units were earmarked, in part, for the previous master site plan modification approval (MSPM 05-003) As such, a traffic impact statement prepared by Pinder Troutman Consulting, Inc. was submitted in conjunction with the conditional use request. On February 3, 2006, staff had received confirmation from the Traffic Division of Palm Beach County that the proposed project is part of the previously approved Quantum DRI, and therefore, meets the Traffic Performance Standards of Palm Beach County However, the allocation of commercial square footage changed between the office, retail, and restaurant uses since when the County reviewed the impact statement. Also, an exclusive east-bound right- turn lane onto the project's main access driveway on Gateway Boulevard would have to be provided and no building permits are to be issued after the build-out date of 2007 Therefore, an updated Traffic Performance Standards review letter will be required at the time of permitting (see Exhibit "C" - Conditions of Approval) Memorandum No PZ 06-058 Quantum Park & Village South Master Site Plan, MPMD 06-001 Page 4 The City's water capacity, as increased through the purchase of up to 5 million gallons of potable water per day from Palm Beach County Utilities, would meet the projected potable water for the project. Local piping and infrastructure improvements may be required, especially on the water delivery system for the project, depending upon the final project configuration and fire-flow demands. These local improvements would be the responsibility of the site developer and would be reviewed at the time of permitting Sufficient sanitary sewer and wastewater treatment capacity is currently available to serve the project. Rre staff reviewed the site plan and determined that the Fire Department expects to be able to maintain an adequate level of service for the subject project, with current or anticipated staffing Infrastructure requirements such as hydrants and roadways will be addressed during plan reviews and permitting It must be noted however, that the project is in an area with significant growth in the past year The Fire Department supports this project with the understanding that Fire Station No 5 will be available when these structures are ready for occupancy The Police Department notes that the proposed project would have not have a negative impact on department operations. RECOMMENDATION Staff has reviewed this master site plan modification request and recommends approval, contingent upon satisfying the comments indicated in Exhibit "c" - Conditions of Approval Any additional conditions recommended by the Board or City Commission shall be documented accordingly in the Conditions of Approval MRfej Xc: Central File S:\Plaming\SHARED\WP\PROJECTS\Quantum Park &. V111age\S8MP 02-001 south\MPMD 06-001 \Staff Report.doc Exh..Jit 'A' - Location fv'~~p . 250 o 500 1,000 1,500 II 2,000 W~E 'Feet T s ~T~ ~ ~, 'i~~t 9'''~~;;;'-:, I Hq ...:-- , Iii \I11~n ,f '--, /.. ~ --:n.----.,~ ('~ . I! '/1/ 1ji -'t~-q~.......~ 'I N \/11 l)f '~---$jf 4i ~ ;.~~"~" ~:::: 4 ~I ~ 1 rt" '11' 'f"" l<~~) II ,~; '1., I .:1$< . . . _ I ..;;.-'. od f ......... "r.- ~v/ I'!; 1" .I" '11', ',;1\ Iii ....11 ~=-. '!' '-. ., :: ~ ~il I ""TIB I --, $ ", t . \., e " 11 \-' , III ~ ....-<~~ -II) II.;;;' II 11m L,i' . I >oAA"'~~ ":ft.,___J_;;.,,1 1!111~. ~hl. --'-~7-_:::::::C~;~" ;"E ~il(j~il. . - ~~~ i I.~ rn . . / ':.,' ;l".i' ,~II ':~..J:..:-.... re> . .' z:s ". '" . .., 'i , =< It' " " I; ... ~'. ,,",," /') ';J ~K, ~ / ,/..J 47 ,?",", II ;;i!l"_ " # 7' #.7~, '- Jil~. ....;,;;;"...1 'i-I' I q c:..., ''i' .__'::' ". I ~ ~_". C~>:r~"~-""- ...,Cf>J,I; .~ ~.:;"<~..,,e,,<.'" ,..~l.'.....!!J..... _.J I. .....1'. ~.~J~ ')'n ,- ~i~~j . I . .,. : :~..~"~. . "r\ ~-' r . II ~ jJ_~\"III. .:,~: I (~frJl' it 'lrt . I~t., iI, ).; "II G4L~.i ."11: i I 1__.. .,.J',!I' 1 ,J. C:. ~ ~r' ' : _. ,F <:0; 'f: IJ I 111"i--', ~,:' II I : ---.. <9 .... r~" J -d-"'-':! f:..----i~.., : ',-: @" (!)i" 1i~1 el , i l-~r I-f~~~:=~:~.-=.=...-------------h----..! ) ~. ,,~ n ",. ::- " :i...' ~j,. ,{~~~::: ~ ~ ~~- :~'"' !.t,':.' '~ i .s ~! , ! '~--~:- I PI I II :;; II ~ o ti$] .. :~\'- '~,', i i I ....-J ..... ---~i.i """........ J) EXH IBIT B U, UI:" !,k -1 ~ ""d , ~ I~~ I~~ ! II I QYANTUM TOWN CENTRE I lam 111111 ~i~t IOYNTONIEAOULOIUDA -II- illll ~~~ ! QUANT1.IMPAIlU.VlUAGE.LLC nil ;'II'!; J~:!!iSE 1500 QUANT1.IM u.ns DIUVE 101 khB I .. ~ ~ IOYNTON lEACH. fL 33<426 U U ~ ~ C "'CIINCI"f(IIIMIllM.,oHII.MIlCnT.--.uM&~"""~~""'.-rID. JtO_OI'..-.............oa.....MItII..lInlOOUICIDoa__..NWmaM............WIftIDVI'....__WUftWl~ClI'.....~1IC I ! U! I I _ zRd I PDF created with pdfFactory trial version www.Ddffactorv.com ,. ,.,.,. BiB 11111 'Ull BiB - -- qlp III!I II t i EXHIBIT B n II i ~ II I II ... mHII ~ n lIP I ii i, ~! i I IIImw: ~ I ' S I I ,~u w !...., Ii. I ~ ~ i ~e - > I ~ I. UiUiI-'li II IIIUII P ,: I! I::! U.~ I ;; I: Q ; , ; iQ , I . . . I . ~ "II B .. ',',l~ ~! ~ ~ . H!II~ ~ ~b I ~ . i I ~ n ~ II ~ ~I~qi ih.J !H Ipm ~ m-I',aIU I j i II i II'III~ i~:~ IDn;i lill m.i~H Ip II' IlII'''' 'I'jlll 1111~_r.:~ Il i i .,I~ ~I m; ~i I, j;i: i ~ h II li,iI. J~~~ U · Ih 'I .? Z III II'~ j. Im~! !~, ~i lit -i ~n b Ii;' ! . ! I I .-p~, tH lU 51 Ilhllll Ili IIi Iii II ili iii ili I ;! 111~!!ljil; Iii' I i !im:1illi! i I;l,lil 'I"!I; I il! II! lij II ill I! I! I i ~ll ~I!~llil !!Ill !llllllr~lll ~jlll!ll!iiil Iii I~ !li II!I i i III ilillr illlll! ll~ I!l ill ! II i !i~iji!illill 'jl Ii 'I! ill! I! III Ii!! illlilll! 111111111111111 ! ! i 1111 i ~ .' I lli I~~ h j', ,U 9 I! hi' , >11 :s~1 II 111111 IIQ1JANTUMTOWNCENTREII~mll!111 ~i~t :; ~ ~ I. ;1 5 i IOYNTON lEACH. FLONDA .,l~ hili ~~~ ..', !>! ~,., I 1- I QUANTUMPAIlK.&.VII,u.GE.LLC. nil ;'II-!; Jt:I! L...... Z e ~ 2500 QUANTUM lADS DRIVE 101 lihB I .. ~ d II IOYNTON lEACH. fL 33426 ~:U6 ~ o "'ClI/IHCII'MlttNIOItoIDNlLMftITT.WIUIofoMI,~""'MaaIICIIUMCoML____ MOMIlI'Qln.-.............aa___.~_~..N/frIOllM~............'IMI___~~Of~.uaancn.1MC. PDF created with pdfFactory trial version www.Ddffactorv.com EXHIBIT "C" Conditions of Approval Project name" Quantum Park & Village South Commercial File number MPMD 06-001 Reference' 20dreview plans identIfied as a Master Plan Modification wIth a March 7. 2006 Planning & Zoning date stamp marking. DEPARTMENTS INCLUDE REJECT PUBLIC WORKS - General Comments. None X PUBLIC WORKS - Traffic Comments. None X ENGINEERING DIVISION Comments. None X UTILITIES Comments. None X FIRE Comments. None X POLICE Comments. None X BUILDING DIVISION Comments. None X PARKS AND RECREATION Comments: None X FORESTERlENVIRONMENT ALIST Comments None X PLANNING AND ZONING Comments 1 The accompanying site plan (COUS 06-003) proposes 18,768 sauare feet of X COA 03/24/06 2 DEPARTMENTS INCLUDE REJECT office, 23,262 square feet of retail, and 39,722 square feet of restaurant. However, the master sIte plan tabular data indIcates that 27,069 square feet of office, 36,516 square feet of retail, and 20,750 square feet of restaurant is proposed. The master site plan tabular data conflicts With the technical sIte plan. Both plans should match each other and the discrepancy between the two (2) must be rectIfied. 2. The Quantum Park & Village South Master Plan requires 937 parking X spaces and provides 1011 parking spaces, a net surplus of 74 parking spaces. This should be noted as such on the master site plan tabular data at the time of penrutting. The par1a.ng methodology can be derived from the accompanyinJ1; staff report (PZ 06-058). 3 The project must obtain approval from the School Distnct of Palm Beach X County regardinJ1; school concurrency 4 On February 3, 2006, staff had received confirmation from the Traffic X Division of Palm Beach County that the proposed project is part of the previously approved Quantum DRI, and therefore, meets the Traffic Performance Standards of Palm Beach County However, the allocation of commercial square footage changed between the office, retail, and restaurant uses smce when the County reVIewed the Impact statement. Also, an exclusIve east-bound right-turn lane onto the proJect's main access dnvewayon Gateway Boulevard would have to be proVIded and no buildmg penruts are to be Issued after the build-out date of 2007 Therefore, an updated Traffic Performance Standards reVIew letter will be required at the time of permittmg;. 5 No portion of the development may drain mto the sand pine preserve area. X ADDITIONAL PLANNING & DEVELOPMENT BOARD COMMENTS. Comments: 6 None X ADDITIONAL CITY COMMISSION COMMENTS. Comments: 7 To be determined. MWR/elJ S:\Planning\SHARED\WP\PROJECTS\Quantum Park & Village\SBMP 02-001 south\MPMD 06-001\COA.doc Meeting Minutes Planning and Development Board Boynton Beach, Florida March 28, 2006 Motion Mr Cwynar moved to approve Item VII B-1, Quantum Park & Village South Commercial conditional use/major technical site plan modification to construct a total of 129 dwelling units, distributed amongst a five-story condominium building (at approximately 65 feet in height), three mixed-use buildings, and two 2-story apartment buildings. The project also proposes 18,768 square feet of office, 23,262 square feet of retail, and 39,722 square feet of restaurant on a 14.265-acre parcel on a Mixed-Use pod in the Planning Industrial Development zoning district with the modifications of the applicant on Item 37 and the rejection of Item 51 in the Conditions of Approval, Exhibit C. Mr Baldwin seconded the motion that passed 7-0 Master Plan Modification Description Quantum Park &. Village South Commercial MPMD 06-001) Eugene Gerlica Quantum Park & Village, LLC Southwest corner of Gateway Boulevard and High Ridge Road Master site plan modification approval to construct an additional 129 dwelling units (for a total of 363 dwelling units), 18,768 square feet of office, 23,262 square feet of retail, and 39,722 square feet of restaurant on a 26.17-acre parcel on a Mixed-Use 9MU) pod in the Planned Industrial Development (PID) zoning district. 2 Project: Agent: Owner' Location Chair Wische asked the applicant's position on the five Conditions of Approval Mr Gerlica responded they accepted all five conditions. Board Attorney Tolces swore in Mr Doug McDonald, the owner Doug McDonald, Chief Executive Officer, Quantum Group of Companies, 2500 Quantum Lakes Boulevard, spoke of the nine buildings visible along Gateway Boulevard. This is where the 39,722 square feet of restaurant would be. What they tried to do was coordinate the outside patio areas of the proposed development with the single use retail buildings, which range in size from 6K square feet down to 3 5K square feet. They maximized as much interconnecting area as they could to create the patio areas, but different tenants would require different kinds of patios. They over landscape everything in Quantum Park. Unlike many other developers, he had been coming to the Board for ten years and they still owned all of Gateway Boulevard except the piece they sold to the School District. This stretch of Gateway Boulevard from High Ridge Road west is what Quantum Park was really about, and it had taken years to do it. His vision was to come before the Board in a couple of months with a Notice of Proposed Change (NOPC-16), which would encompass some more land they own along Gateway Boulevard It would take the mixed-use project and keep moving it down the street and create a pedestrian corridor from Renaissance Commons all the way to I- 95 It was there now They wanted to embellish it. He had heard Staff and the City Attorney say 13 Meeting Minutes Planning and Development Board Boynton Beach, Florida March 28, 2006 that Quantum was the jewel of Boynton Beach. He thought they had done a pretty good job of it so far, but what they were starting to do now was what was really important. He hoped the City would be flexible. Mr McDonald declared Quantum was the largest single generator of tax dollars for Boynton Beach. He invited everyone to check out the improvements going in on Gateway Boulevard because he believed they were going to be very special Mr Johnson reported Staff reviewed the master site plan modification request to make sure it complied with the LOR and it did, subject to satisfaction of all comments in Exhibit C, Conditions of Approval Chair Wische opened the floor for public comments, closing it when no one came forward. Motion Mr Cwynar moved to grant master site plan modification approval for Quantum Park & Village South Commercial to construct an additional 129 dwelling units (for a total of 363 dwelling units), 18,768 square feet of office, 23,262 square feet of retail, and 39,722 square feet of restaurant on a 26 17-acre parcel on a Mixed-Use pod in the Planned Industrial Development zoning district, subject to the Conditions of Approval Mr Casaine seconded the motion that passed 7-0 C. Zoning Code Variance (Moved to start of public hearing) 1 Project: 912 N.W 13th Avenue (Hatcher) (ZNCV 06- 004) William Hatcher York Builder, Inc. 912 N W 13th Avenue Request for relief from the City of Boynton Beach Land Development Regulations, Chapter 2, Zoning, Section 5.C.2, requiring a foot minimum lot frontage of 60 feet to allow a frontage of 50 feet, a variance of 10 feet within the R-l-AA Single-Family Residential zoning district. Agent: Owner' Location Description o Zoning Code Variance (Moved to start of public hearing) 1 Project: 1370 S.W. 26th Avenue (Kervern> (ZNCV 06- OOS) Scott and Stephanie Kervern Scott and Stephanie Kervern 1370 S.W 26th Avenue Request relief from the City of Boynton Beach Land Development Regulations, Chapter 2, Zoning, Section 11, Supplemental Regulations, E., requiring minimum rear setback of 8 feet from the property line for the construction of a pool, to allow a rear Agent: Owner' Location Description 14