December 19,2002
Mr Michael W Rumpf
Director of Planning & Zoning
Department of Development
City of Boynton Beach
POBox 310
Boynton Beach, FL 34425-0310
RE: Footprints Daycare
TRAFFIC PERFORMANCE STANDARDS REVIEW
Dear Michael:
The Palm Beach County Traffic Division has reviewed tile traffic statement for the project
entitled, Footprints Davcare. pursuant to the Traffic Performance Standards in Article 15
of the Palm Beach County Land Development Code The project is summarized as
follows
Location:
Municipality:
Existing Uses:
Proposed Uses:
New Daily Trips:
Build-out:
On Fedeial Highway. North of Boynton Beach Boulevard
Boynton Beach
None
2,264 SF Daycare Center
125
2003
Based on our review, the Traffic Division has determined that the project meets the
Traffic Performance Standards of Palm Beach County
Sincerely,
If you have any questions regarding this determination, please contact me at 684-4030
OFFICE OF THE COUNTY ENGINEER
/Y),
Masoud Atefi, MS
Sr Engineer - Tra
jl C ,J .~
CC Pinder Troutman Consulting Inc.
File. General - TPS - Mun - Traffic Study Review
'wr:lo.., f r ~ ~ Wi ~ 1:'\ n. ".
I, ~ ------d III
' I,!,
': I
I OtL 2 1 2002 I ~/
L.-. ...~ j
PLAl\i~ir'.~ M~O
ZONING DEPT
F '\TRAFFIC\ma\Admin\Approvals\021209.doc
....
-"
Facsimile
TRANSMITTAL
CITY OF BOYNTON BEACH
100 E. BOYNTON BEACH BOULEVARD
P.O. BOX 310
BOYNTON BEACH, FLORIDA 33425-0310
FAX: (561) 742-6259
PLANNING AND ZONING DIVISION
to: Andre Faulkner, DZN
fax #: 305-576-10atl ~,
date: December 23,2002
from: Lusia Galav, Principal Planner
re: 1 ST REVIEW COMMENTS FOR Footprints Daycare & Preschool
Please find attached the first review comments for your project. To stay on the
current review schedule, please do the following steps listed below, and bring all
documents to the TRC scheduled for January 21,2003.
1. Revise your plans mcorporating all comments listed herem, includmg the addition of
notes on plans to confirm response to general statements/ comments, and bnng 10 copIes
to the TRC reVIew meetmg (full sets mcludmg all pages ongmally submItted);
2. SubmIt the addltIOnalmformation as requested wlthm the attached comments; (l.e traffic
analysis, engineenng certificatIOn, etc.)
3. Prepare a wntten response (7 copIes) conslstmg of a lIst bnefly summanzmg how each
comment has been addressed on the revIsed plans or wIth the supplemental mformatIOn
includmg locatIOn on the plans ( thIS promotes an expedItious 2nd reVIew by staff and
your project representatives dunng the TRC meeting );and
4
SubmIt reductIOns (8 12 X 11) for the proposed
site plans, elevatIOns and landscapmg plan (thIS
IS reqUIred for the final report and publIc
presentation).
Planning and Zoning Division
City of Boynton Beach
Boynton Beach, Florida 33425
742-6260
Fax: 742-6259
The applIcant should not attend a TRC (2nd reVIew) until all documents have been revIsed and
copied for staff reVIew. Ifplans wIll not be fully revIsed and brought to the scheduled TRC
meetmg, contact LUSIa Galav m this office by the Thursday pnor to the scheduled meetmg date
Projects deviating from the ongmal schedule are elIgible for reVIew at subsequent meetings,
WhICh are held every Tuesday. To reschedule, contact Shene Coale, by the Thursday pnor to the
Tuesday TRC meeting that you desIre to attend. The remamder of the review schedule will be
adjusted accordmgly. If you have questions on the attached comments, please contact the
respective reviewer usmg the attached lIst ofTRC representatives.
If the plans are reasonably complete and all sIgmficant comments are addressed followmg TRC
(2nd revIew), the project is forwarded to the Planmng and Development Board Meetmg that falls
approxImately 2 to 3 weeks following the TRC meeting. An "*,, by any comment Identifies a
comment that must be addressed pnor to movmg forward to the Planning and Development
board.
Note: Items recogmzed by staff as typically outstandmg at thIS point mclude a traffic report
and/or confirmatIOn of the traffic concurrency approval from the Palm Beach County
dramage certIfication by a lIcensed engmeer, sIgned "RIder to Site Plan ApplIcation"
form and colored elevations of the proposed project. ThIS mformation IS necessary for
the project to proceed. If you have submItted thIS mformatIon, please dIsregard thIS note.
DEPARTMENT REPRESENT A TIVE REPRESENT A TIVES' PHONE FAX
DESIGNEE
Engmeering Dave Kelley Launnda Logan 742-6482 742-6485
Building Don Johnson TImothy Large 742-6352 742-6352
Fire Department Steve Gale Bob Borden 742-6602 364-7382
Rodger Kemmer 742-6753 742-6357
PolIce Department Marshall Gage John Huntmgton 737-6167 737-3136
UtilIties Pete Mazzella H. DaVId Kelley Jr. 742-6401 742-6485
PublIc Works-General Larry QUinn Launnda Logan 742-6482 742-6485
Public W orks- Traffic Jeffrey LIvergood Launnda Logan 742-6482 742-6485
Parks & RecreatIOn John WIldner 742-6227 742-6233
Forester/EnvIronmentalIst Kevm Hallahan Kevin Hallahan 742-6267 742-6259
Plannmg & Zonmg MIchael Rumpf, LUSIa Galav 742-6262 742-6259
CHAIRMAN
Revised 01/14/02
S:IPlanningISHAREDlWPIPROJECTSIFootprin!s Daycare & Preschool Ctrlls! Review comments FAX COVERdoc
1 st REVIEW COMMENTS
Conditional Use
PrOject name' Footpnnts Daycare & Preschool Center
FIle number' CaDS 02-008
Reference' 1 slreVIew plans IdentIfied as a CondItIOnal Use wIth a December 4. 2002 Plannmg and Zomng
Department date stamp markIng
i
DEPARTMENTS INCLUDE REJECT
PUBLIC WORKS - General
Comments.
1 Pnor to pernut applIcatIOn contact the PublIc Works Department (561-742-
6200) regardmg the storage and handlmg of refuse The dumpster WIll be
supplIed by PublIc Works.
2. IndIcate by note that the sIte dumpster enclosure shall be constructed m
accordance wIth CIty Standard A-8807
3. A mImmum dumpster pad (concrete) IS reqUIred measunng 10 feet x 10 feet
(msIde dImensIOn mcludmg gates) (LDR, Chapter 7.5, ArtIcle II, SectIOn
5.J and ArtIcle ill, SectIOn 9.A.9.a)
4. The reqUIred gates for the dumpster shall contam long steel rods to drop mto
the pavement m order to secure the gates m the open and closed posItIons.
Drilled holes (for concrete) or metal sleeves (for asphalt) shall be provIded
for the lockIng rods.
5 Wall for the enclosure shall be proVIded on three SIdes and are to be a
mImmum of SIX (6) feet hIgh and shall be CBS constructIOn WIth a fimsh
matchmg that of the adjacent buildmg(s) Accent shrubs shall be proVIded
along the screen walles) (LDR, Chapter 7.5, ArtIcle II, SectIon 5.J, SectIOn
5.J and ArtIcle ill, SectIOn 9.A.9.a, and Chapter 9, SectIon 10.C.3).
PUBLIC WORKS - Traffic
Comments:
6 PrOVIde notIce of concurrency (Traffic Performance Standards RevIew)
from Palm Beach County Traffic Engmeermg.
7 IndIcate dISposItIOn of 20 foot road nght-of-way shown along west property
lme. Title may be obtamed by entenng the abandonment process
8 Relocate the handIcap parkIng space to the southernmost, angled space to
prOVIde the shortest, reqUIred, route to the entrance
9 Mimmum backup dIstance reqUIred for 450 parkmg is 14 feet, SIX mches per
CIty Standard Drawmg B-900 13 MmImum perpendIcular dImenSIOn
reqUIred for 450 parkmg is 19 feet-l mch (I6 feet-OO mches shown on
plans).
1ST REVIEW COMMENTS
12/23/02
2
DEPARTMENTS INCLUDE REJECT
10. Reference City Standard Drawmgs B-98001 and B-90013 for all parkmg,
handIcap parkmg and stnpmg detaIls. Note that concrete parkmg stops shall
be 6 (SIX) feet m length.
11 Delete reference to "Tow-Away Zone" on the HandIcap ParkIng SIgn detail
12 Two SIgn mountmg details are provIded whIch confhct wIth each other
Addlttonally one IS a Broward County standard detail whIch WIll not be
acceptable here. Please resolve confllct(s) and provIde details for Boynton
Beach/Palm Beach County.
UTILITIES
Comments.
13 No utilIty plan was mcluded WIth thIS submIttal, therefore, the UttlItIes
Department considers thIS plan mcomplete as submItted. However, thIS
proposed master sIte plan IS located where uttlIty support IS avaIlable. We
are provIdmg only a cursory reVIew of the master sIte plan as submItted at
thIS tIme AddItIOnal comments WIll be reqUIred after a utilIty plan has been
submItted.
14 All uttlIty easements shall be shown on the sIte plan and landscape drawmg
so that we may determme whIch trees may mterfere WIth UtilItIes. In
general, palm trees will be the only tree speCIes allowed wlthm utilIty
easements. Canopy trees may be planted outSIde of the easement so that
roots and branches WIll not Impact those utilIttes wIthm the easement m the
foreseeable future. The LDR, Chapter 7.5, ArtIcle I, SectIOn 18.1 glVes
publIc uttlitIes the authonty to remove any trees that mterfere WIth utIlIty
sefVIces, eIther m utilIty easements or publIc nghts-of-way
15 FIre flow calculatIOns will be reqUIred demonstratmg the CIty Code
reqUIrement of 1,500 g.p.m. as stated m the LDR, Chapter 6, ArtIcle IV,
SectIOn 16, or the reqUIrement Imposed by msurance underwrIters,
whIchever IS greater (see CODE, SectIOn 26-16(b)).
16 Appropnate backflow preventers WIll be reqUIred on the domesttc water
sefVIce to the bui1dmg, and the fire spnnkler lme If there IS one, m
accordance WIth CODE, SectIOn 26-207.
17 ComprehensIve Plan PolIcy 3 C.3 4 reqUIres the conservatIOn of potable
water CIty water may not, therefore, be used for lITIgatIOn where other
sources are readily avaIlable.
FIRE
Comments:
1ST REVIEW COMMENTS
12/23/02
3
, tI
DEPARTMENTS INCLUDE REJECT
18 The sIte plan and master plan desIgn documents shall adhere to Chapter 9 of
the Code of Ordmances of the CIty of Boynton Beach entItled "FIre
ProtectIOn and PreventIOn." ThIs ordmance adopts NFP A 1, Fire
Prevention Code, 2000 edItIon, and NFP A 101, Life Safety Code, 2000
edItIon. (These codes, as amended, are IdentIfied as the Florida Fire
Prevention Code)
19 Hydrant must provIde a fire flow of at least 1500 gpm m addItIon to
domestIc reqUIrements, at a resIdual pressure of not less than 20 pSI.
20 Pursuant to CIty Ordmance 9-3F, the FIre Marshal has developed an
AdmmIstratIVe Order dated May 9, 2001, that provIdes the mInImUm
performance for all secunty gates and emergency access. (Attached)
21 CIty Ordmance SectIOn 9-6, 3 /7-11 reqUIres approved automatIc fire
spnnkler systems throughout mstItutIOnal or educatIOnal buildmgs,
hospItals, nursmg homes, homes for the aged, convalescent centers,
rehabilItatIOn facilItIes, day care centers for more than 12 clIents under 1
year of age, adult congregate lIvmg facilItIes, and all occupanCIes and uses
of slITlllar nature.
POLICE
Comments: NONE
ENGINEERING DIVISION
Comments:
22 Numerous errors and omISSIOns have been noted on these proposed plans
and m thIS reVIew comments report. Drawmgs need to be thoroughly
checked and coordmated by the consultmg engmeer It IS the responsibilIty
of the consultmg engmeer to familIanze hImself wIth and utIlIze the CIty of
Boynton Beach Land Development RegulatIOns pnor to submIssIOn of
plans. QualIty control IS the responsibIlIty of the consultmg engmeenng -
not the CIty of Boynton Beach.
23 Add a general note to the SIte plan that all plans submItted for specIfic
permIts shall meet the CIty'S Code reqUIrements at tIme of applIcatIon.
These permIts mclude, but are not lllmted to, the followmg: pavmg,
dramage, curbmg, site lIghtmg, landscapmg and lITIgatIOn. PermIts requIred
from other permI ttmg agencIes such as Flonda Department of
Transportation (FDOT), South Flonda Water Management DIStrIct
(SFWMD), Lake Worth Dramage DIStrIct (LWDD), Flonda Department of
EnVIronmental ProtectIon (FDEP), Palm Beach County Health Department
(PBCHD), Palm Beach County Engmeermg Department (PBCED), Palm
1ST REVIEW COMMENTS
12/23/02
4
DEP ARTMENTS INCLUDE REJECT
Beach County Department of EnvIronmental Resource Management
(PBCDERM) and any others, shall be mcluded wIth the pemut request.
24 All work done wlthm the Federal HIghway nght-of-way shall reqUIre FDOT
approval and pemuttmg.
25 All comments requITIng changes and/or correctIOns to the plans shall be
reflected on all appropnate sheets.
26. Show zomng and land use on sIte survey (LDR, Chapter 4, SectIOn 7.A.)
27 Show all eXlstmg utilItIes on sIte plan (LDR, Chapter 4, SectIOn 7.A.3).
28. EXlstmg power poles and overhead lmes wlthm the subject property are
depIcted on the sIte survey but nothmg IS mentIoned regardmg theIr
dISpOSItIOn on the sIte or CIVIl plans, please clanfy.
29. EXIstmg lIght poles and overhead lmes eXIst along Federal HIghway but are
not depIcted on the sIte survey; please correct.
30 The lIghtmg desIgn shall prOVIde a mlmmum average lIght level of one foot-
candle. On the lIghtmg plan, speCIfy that the lIght poles shall wIthstand a
140 MPH wmd load (LDR, Chapter 23, ArtIcle II, SectIOn A.I.a and
Flonda Buildmg Code). PrOVIde a note that the fixtures shall be operated
by photo-electncal control and shall remam on until 2.00 a.m. (LDR,
Chapter 23, ArtIcle II, SectIon A.I.a.) Include pole wmd loadmg, and pole
details m conformance WIth the LDR, Chapter 6, ArtIcle IV, SectIOn 11,
Chapter 23, ArtIcle I, SectIOn 5.B.7 and Chapter 23, ArtIcle II, SectIOn A on
the Llghtmg Plan. Glare whIch IS readIly perceptible at any pomt at or
beyond the property one of the property on whICh the use IS located IS
prohibIted (LDR, Chapter 2, SectIOn 4.N 7). If possible please prOVIde
photometrIcs as part of your TRC plan submIttals - It IS much eaSIer to
IdentIfy and correct any defiCIencIes now than while you are waltmg on a
pemut.
31 It WIll be necessary to replace or relocate large canopy trees confllctmg WIth
adjacent lIght fixtures to elImmate future shadowmg on the parkIng and
drlVlng surface(s) (LDR, Chapter 23, ArtIcle II, SectIon A.lob).
32 Show SIght tnangles on the landscape plans (LDR, Chapter 7.5, ArtIcle II,
SectIOn 5.H.). Reference FDOT Standard Index 546 for the SIght tnangles
along all collector and arterIal roadways.
33 IndIcate, by note on the landscape plan, that withm the SIght tnangles there
shall be an unobstructed cross-vIsibilIty at a level between 2.5 feet and 6
feet above the pavement (LDR, Chapter 7.5, ArtIcle II, SectIOn 5.H.).
34. Landscaped areas shall be protected from vehIcular encroachment by a
continuous. raised curb (LDR. Chaoter 7.5. ArtIcle II. SectIon 5.A. and
1ST REVIEW COMMENTS
12/23/02
5
DEPARTMENTS INCLUDE REJECT
Chapter 22, ArtIcle II, SectIon E.)
35 The CIty has an lITIgatIOn system and landscapmg m the medIan of Federal
HIghway (US HIghway 1) Any damage to the lITIgatIOn system and/or
landscapmg as a result of the contractor's operatIOns shall be repaIred or
replaced to the eqUIvalent or better grade, as approved by the City of
Boynton Beach, and shall be the sole responsibIlIty of the developer Please
acknowledge thIS notIce m your comments response and add a note to the
plans WIth the above stated mformatIOn.
36 The medIans on Federal HIghway and the chase area(s) adjacent to thIS
project have eXlstmg decoratIve bnck pavers belongmg to the City of
Boynton Beach. Any damage to the bnck pavers as a result of the
contractor's operatIOns shall be repaIred or replaced to the eqUIvalent or
better grade, as approved by the CIty of Boynton Beach, and shall be the
sole responsibilIty of the developer Please acknowledge thIS notIce m your
comments response and add a note to the plans wIth the above stated
mformatIOn. -
37. LIve Oak trees placed along the penmeter should be placed a mInImUm of
10 (ten) feet off the property lme to allow for future mamtenance.
38 Ensure that all trees and palms are clear, at matunty, of all overhead WIres.
39 PrOVIde an engmeer's certIficatIOn on the dramage plan as speCIfied m
LDR, Chapter 4, SectIOn 7.F.2
40 At a mInImUm, eXlstmg and proposed elevatIOns, proposed dramage
structures, proposed treatment facIlItIes and flow arrows are reqUIred on the
Clvil/Dramage Plan m accordance WIth the LDR, Chapter 4, SectIOn 7.F so
that an evaluatIOn maybe made of the pre- and post-development
condItIons. SpecIfy storm sewer dIameters, mlets types, etc on dramage
plan. ProVIde prelImmary calculatIons showmg pre- and post-development
permeabilIty areas and storage reqUIrements. Full dramage plans m
accordance WIth the LDR, Chapter 6, ArtIcle IV, SectIOn 5 wIll be reqUIred
at the tIme of pernuttmg.
41. IndIcate, by note, that the dramage system shall conform to CIty Standard
Drawmg B-9l 007 and reVIse details accordmgly.
42. IndIcate by note that catch basm and manhole covers shall be bIcycle proof
(LDR, Chapter 6, ArtIcle IV, SectIOn 5.A.2.f)
43. IndIcate to what standard the project IS to be constructed, If the FDOT
Standard SpeCIficatIOns for Road & Bndge ConstructIon and Standard
Index are to be used - the 2000 SpeCIficatIons are recommended smce they
. contam both EnglIsh and Metric UnIts.
44 PrOVIde wntten and graphIc scales on all sheets.
1ST REVIEW COMMENTS
12/23/02
6
DEPARTMENTS INCLUDE REJECT
45 Correct lot acreage call outs under the sIte data.
46 IdentIfy Phases I and II on the plans. If addItIOnal constructIOn IS planned,
Staff recommends Improvements be shown on the plans to aVOId a second
reVIew by CommIssIOn.
47 DetaIls as shown on CIVIl sheet C.2 WIll not be revIewed for constructIOn
acceptabIlIty at thIS tIme. All engmeermg constructIon details shall be m
accordance WIth the applIcable CIty of Boynton Beach Standard Drawmgs
and WIll be revIewed for constructabIlIty at the tIme of constructIOn permIt
applIcatIon.
BUILDING DIVISION
Comments.
48 IndIcate wlthm the SIte data the occupancy type of the buildmg as defined m
Chapter 3 of the 2001 Flonda Buildmg Code. The proposed occupancy of
the structure shall be clearly defined on the plans per SectIon 306 1.2 and
313.1 of the 2001 Flonda Buildmg Code
49. The mInImUm reqUIred sanItary facilItIes shall comply WIth Table 403 1 of
the 2001 Flonda BuIldmg Code, Plumbmg for the proposed occupancy.
See also SectIOn 403.7
50. Add to the buildmg that IS depIcted on the drawmg tItled SIte plan and floor
plan a labeled symbol that IdentIfies the locatIOn of the handIcap accessible
entrance doors to the buildmg. Flonda AccessibIlIty Code for Buildmg
ConstructIOn, SectIOn 4 1.2, 4.3.
51. Add a labeled symbol to the SIte plan drawmg that represents and delmeates
the path of travel for the accessible route that IS requIred between the
accessible parkIng space and the accessible entrance doors to the buildmg.
The symbol, requIred to be installed along the path, shall start at the
accessible parkIng space and termmate at the accessible entrance doors to
the buildmg. The symbol shall represent the locatIOn of the path of travel,
not the locatIOn of the detectable warnmg or other pavement markIngs. The
locatIOn of the accessible path shall not compel the user to travel m a
dnve/lane area that IS located behmd parked vehIcles. IdentIfy on the plan
the WIdth of the accessible route (Note' The mInImUm WIdth reqUIred by
the code IS forty-four (44) mches) Add text to the drawmg that would
mdlcate that the symbol represents the accessible route and the route IS
deSIgned m complIance WIth SectIOn 4.3 (Accessible Route) and 4.6
(ParkIng and Passenger Loadmg Zones) of the Flonda AccessibilIty Code
for Buildmg ConstructIOn. Please note that at tIme of permIt reVIew, the
applIcant shall prOVIde detailed documentatIOn on the plans that WIll venfy
that the accessible route IS m complIance WIth the regulatIons specIfied m
the Flonda AccessibIlIty Code for BUIldmg ConstructIOn. ThIS
1 ST REVIEW COMMENTS
12/23/02
7
DEPARTMENTS
documentation shall mclude, but not be lllruted to, provIdmg fimsh grade
elevations alon!:! the nath of travel.
52 IdentIfy wIthm the sIte data the fimsh floor elevatIOn (lowest floor elevatIOn)
for the buildmg. Venfy that the proposed elevatIOn IS m compltance WIth
regulatIOns of the code by addmg specIficatIons to the sIte data that address
the followmg Issues [SectIon 3107 1.2, Chapter 31 of the 2001 Flonda
Buildmg Code]
a) The desIgn professIOnal-of-record for the project shall add the
followmg text to the SIte data. "The proposed fimsh floor elevatIOn
_' _ NGVD IS above the hIghest 100-year base flood elevatIOn
appltcable to the bUIldmg SIte, as determmed by the South Flonda
Water Management DIStrICt'S surface water management constructIon
development regulatIons."
b) From the FIRM map, IdentIfy m the SIte data the title of the flood zone
that the buildmg IS located wIthm. Where applIcable, specIfy the base
flood elevatIOn. If there IS no base flood elevatIOn, mdIcate that on the
plans.
c) IdentIfy the floor elevatIOn that the desIgn professIOnal has establtshed
for the buildmg wIthm the footpnnt of the buildmg that IS shown on
the drawmgs tItled SIte plan, floor plan and paVIng! dramage (cIvil
plans).
53. On the drawmg tItled SIte plan, IdentIfy and label the symbol that represents
the property lIne.
54 As reqUIred by Chapter 4, sectIOn 7 of the Land Development RegulatIOns,
submIt a current survey of the subject property.
55. The buildmg plans are not bemg revIewed for complIance WIth the
applIcable buildmg codes. Therefore, add the words "Floor plan layout IS
conceptual" below the drawing titled Floor Plan found on sheet A-I
56 ConsIdenng that the occupancy classIficatIon of the eXIstmg buildmg will
be changmg, mdIcate on the floor plan drawmg the floor load capaCIty of
the eXIstmg floors. SpecIfy on the plan the eXlstmg and proposed occupancy
classIficatIon as defined m the 2001 Flonda BUIldmg Code. Also, mdIcate
the floor load capaCIty that IS requIred for the new occupancy classIfication.
Changmg the occupancy classIficatIOn of a buildmg will reqUIre that the
bUIldmg comply WIth Chapter 34 of the 2001 Flonda BUIldmg Code The
change of occupancy reqUIres that an engmeer certIfy that the floor loads
WIll comply WIth speCIficatIons of the new occupancy claSSIficatIon.
CertIficatIon of the floor loads and complIance WIth Chapter 34 of the 2001
Flonda BUIldmg Code WIll be reqUIred at tIme of permIt reVIew
57. At tIme of permIt reVIew, submIt sIgned and sealed workmg drawmgs of the
proposed constructIOn.
58 Add to the submittal a oartlal elevation view drawmg of the orooosed
INCLUDE REJECT
I ST REVIEW COMMENTS
12/23/02
8
DEPARTMENTS INCLUDE REJECT
penmeter wall/fence. IdentIfy the type of the walllfence matenal and the
type of matenal that supports the wall/fence, mcludmg the typIcal dIstance
between supports. Also, provIde a typIcal sectIon VIew drawmg of the
wall/fence that mcludes the depth that the wall/fence supports are below
fimsh grade and the heIght that the wall/fence IS above fimsh grade. The
locatIon and heIght of the wall/fence shall comply WIth the wall/fence
regulatIOns specIfied m the Zonmg Code.
PARKS AND RECREATION
Comments. NONE
FORESTER/ENVIRONMENT ALIST
Comments:
Existinl! Trees
59 The applIcant should mdIcate on the landscape plan any eXIstmg trees that
wIll be preserved, relocated, or removed / replaced on the sIte. ThIS should
be mdIcated WIth a separate symbol on the landscape plan sheet LP 1.
[Envlfonnemental. RegulatIOns, Chapter. 7.5, ArtIcle II Sec 7 C.]
Plant List. Sheet LP.l
60. Trees, shrubs / hedges, and groundcover matenals should not be mcluded If
lIsted on the Palm Beach County mvasIVe speCIes lIst. [EnVlronnemental.
RegulatIOns, Chapter 7.5, ArtIcle I Sec 19, A,S]
61 All trees shown on the landscape plans must be 12 feet to 14 feet m heIght
and 3 mches m calIper at tIme of plantmg. [EnVlronnemental. RegulatIons,
Chapter. 7.5, ArtIcle II Sec 5,C, 2 ]
62 The landscape plan does not mclude the CIty SIgnature trees at the mgress /
egress locatIOn to the SIte. [EnVlronnemental RegulatIOns, Chapter. 7.5,
ArtIcle II Sec 5,C,2.1
63 The landscape plan does not mclude the reqUIred seven (7) foot WIde three-
dImensIOnal landscape buffer along Federal HIghway [EnVlronnemental.
RegulatIOns, Chapter 7.5, ArtICle II Sec. 5,D]
Irril!ation System
64 There IS not an ImgatIOn system deSIgn mcluded WIth the landscape plans.
[EnVlronnemental. RegulatIOns, Chapter 7.5, ArtIcle II Sec 5,A.]
PLANNING AND ZONING
1ST REVIEW COMMENTS
12/23/02
9
DEPARTMENTS INCLUDE REJECT
Comments.
65 Smce thIS prOject IS phased, thIS sIte plan IS only valId for one (1) year from
the date of CIty CommIssIOn approval. IndIcate the tnnmg for the phasmg.
66 The survey mdIcates a 20-foot WIde road RIght-of-Way The proposed sIte
plan can only utilIze thIS 20-foot WIde nght-of-way If It IS vacated. If thIS
20-foot WIde nght-of-way has been vacated, provIde the documentatIon
necessary to support the use of thIS nght-of-way
67. The sIte plan must show the locatIon of fire hydrants.
68. The sIte plan must IdentIfy the offiCIal zonmg dIStrICt and desIgnated land
use of the adjacent propertIes.
69. ThIS project must meet Traffic Performance Standards of Palm Beach
County's Traffic DIVISIon pnor to Issuance of a bUIldmg perrmt.
70. SubmIt a color sample / swatch of all major extenor finIshes. Each color
sample / swatch shall be labeled by name, color code and manufacturer.
71. On the elevatIOn drawmgs, mdIcate the proposed color schemes (by
manufacturer name and number) to be used for thIS project.
72. On the SIte plan, show the locatIOn of all outdoor freestandmg lIghtmg
poles. ProvIde a typIcal drawmg that mcludes the heIght and color / matenal
of all proposed freestandmg outdoor lIghtmg poles.
73 Above ground mechanIcal eqUIpment such as extenor meters, utilIty boxes
and transformers shall be VIsually screened (Chap 9 SectIOn 10 CA.).
EqUIpment placed on the walls of the buildmg shall be pamted to match the
buildmg color
74 The SIte plan must show the locatIon of aIr condItIoner UnIts or any other
proposed above grade mechanIcal eqUIpment. ThIS IS to ensure that proper
screenIng IS prOVIded.
75 IndIcate the 10-foot SIte trIangles at the egress on the SIte plan and the
landscape plan (Chapter 7.5, Art. II, Sec 5. H.1 )
76. All reqUIred trees shall be a mInImUm 12 feet overall heIght and 3 calIper
mches when planted (Chapter 7.5, ArtIcle II, SectIOn 5 C.2 )
77 FIfty percent (50%) of SIte landscape matenals must be natIve speCIes.
IndIcate the amount of natIve matenal in the plant lIst of the landscape plan
(Chapter 7.5, ArtIcle II, SectIon 5.P )
78 Indicate on the landscaoe olan the total number of trees and shrubs reauired
1ST REVIEW COMMENTS
12/23/02
10
DEPARTMENTS INCLUDE REJECT
and the number of trees and shrubs provIded.
79 On the Landscape plan, the plant lIst mdlcates more plantmg matenal than
what IS shown on the drawmg. Please clanfy whIch plant matenal wIll be
used.
80 The use of Cypress mulch IS not permItted m the City Of Boynton Beach.
Place a note on the landscape plan mdlcatmg that mulch other than Cypress
shall be used and mamtamed for landscape purposes (Chapter 7.5, ArtIcle
II, SectIOn 5 C.8 )
81. Landscapmg at project entrances shall contam a SIgnature tree at both SIdes
of the entrance (Chapter 7.5, ArtIcle II, SectIon 5.N.). A SIgnature tree IS a
tree WIth blossoms or natural color other than green mtended to beautIfy
project entrances and contribute to the CIty'S Image WIth thIS element of
aesthetIc confOrmIty SIgnatures trees mclude Yellow Elder, Tibouchma
Granulosa, and Bougamvillea. Note that SIgnature trees do not contribute
toward the total number of reqUIred penmeter trees. SIgnature trees must
have 6 feet of clear trunk If placed wlthm the safe-sIght tnangle (Chapter
7.5, ArtICle 2, SectIOn 5.N)
82 Label and dImenSIOn reqUIred landscape buffer on the SIte plan and
landscape plan.
83 All trees proposed m penmeter landscape buffers shall be spaced one (I)
tree per every 30 lmear feet. In addItIon, thIS reqUIrement must be mdlcated
as such m the tabular data on the landscape plan (Chapter 7.5, ArtIcle II,
SectIOn 5.D.and Chapter 7.5, ArtIcle II, SectIOn 5.E)
84. IndIcate source of water for lITIgatIOn on the landscape plan.
85. The landscape buffers adjacent to US HIghway I nght-of-way shall contam
two layers of plant matenal. The first layer shall be a combmatIOn of
colorful groundcover plants and a mmlmum of two colorful shrub speCIes
planted m a contmuous row The next layer shall conSIst of a contmuous
hedge or decoratIve SIte wall. The contmuous hedge (2nd layer) shall be a
mInImUm of 24 mches m heIght, 24 mches m spread and planted WIth tIp-
to-tIp spacmg unmedIately after plantmg. The hedge shall be mamtamed at
four (4) feet. If a decoratIve SIte wallIS used, It shall be constructed not less
than three (3) feet m heIght (Chapter 7.5, ArtIcle II, SectIon 5.D)
86. All dumpsters, recyclIng receptacles shall be screened WIth a SIX (6) foot
hIgh, concrete block stuccoed wall. The color of the dumpster enclosure
shall match that of the prmclple structure (Chapter 9, SectIon 10.E.3 )
87. IndICated the proposed dImenSIOns of the drop off area. Staff recommends
stnppmg and markmg to clearly IdentIfy the drop off area.
88 Provide detail of a standard oarking soace and handicao soace in accordance
1ST REVIEW COMMENTS
12/23/02
11
DEPARTMENTS INCLUDE REJECT
wIth the CIty'S Engmeenng Department Standard Drawmg B-90012.
89. ProvIde a standard handIcap SIgn detail showmg all dImensIOns m
accordance wIth drawmg No B-900 12
90. No sIgnage IS shown on the plans for thIS proJect. ProvIde sIgnage wIth thIS
submIttal or any proposed SIgn wIll reqUIre separate reVIew and approval by
the Commumty Redevelopment Agency Board.
91 Staffbeheves that thIS proposed project constItute an opportumty to develop
a great example for thIS partIcular urban corndor. Staff recommends
mcreasmg the buildmg's entrance feature through the southeast and
northeast corners of the buildmg to enhance the overall appearance of thIS
bUIldmg.
92. PrOVIde safety measures to msure the chIldren's safety m the playground
area from any possible traffi c aCCIdent on Federal HIghway Staff
recommends the placement of a decoratIve four (4) foot hIgh wall
supplemented WIth a fence repeatmg detaIl SImIlar to those on the proposed
bUIldmg.
93 Staff recommends addItIOnal landscape matenal, preferably a hedge, to
buffer the north and south portIOn of the proposed playground area.
MWR/sc