CORRESPONDENCE DEPARTMENT OF DEVELOPMENT PLANNING AND ZONING DIVISION . BUifding . Planning & Zoning . Occupational Licenses . Community Redevelopment July 8, 2002 Mr. Stanley Stripe, Plant Manager UP Fluid Systems 4020 Thor Dri ve Boynton Beach, FL 33426 Re: UF Fluid Systems - Building Addition MMSP 02-046 Dear Mr. Stripe: In response to your request for the administrative review and approval of the modification proposed to the above-referenced, approved site plan, please be informed that the changes as shown on the revised plans date stamped 06/27/02 are "minor", as defined within the Land Development Regulations, Chapter 4- Site Plan Review. This project may continue to be processed by the Building Division as a permit application subject to the following conditions (see attached). Be advised that the proposed changes may require a modification to the building permit. Please contact me at (561) 742-6260 if you have additional questions. Sincerely, cJ~~ -dddV Lusia Galav, AICP Principal Planner Cc: Jose Alfaro, Planner Eric Lee Johnson, Planner S:\PlanningISHAREDlWP\PROJECTS\United ForwardlMMSP 02-046\Approval Letter.doc City of Boynton Beach. 100 East Boynton Beach Blvd., P.O. Box 310 . Boynton Beach, Florida 33425-0310 Phone: (561) 742~350 . www.ci.boynton-beach.fl.us Conditions of Approval Minor Modification to Site Plan Project name: United Forward File number: MMSP 02-046 Reference: 1 st review plans identified with a 06/27/02 Planning and Zoning Department date stamp marking. . , DEPARTMENTS INCLUDE REJECT PUBLIC WORKS - General Comments: None PUBLIC WORKS - Traffic Comments: None UTILITIES Comments: None FIRE Comments: None POLICE Comments: None ENGINEERING DIVISION Comments: 1. The Parking Detail correctly states that striping is to be placed in accordance with City Standard Drawing B-98001. The detail shows stall dimensions of 9 feet by 9 feet. The Standard Drawing specifies 9 feet by 18 feet. Please revise the detail drawing. 2. The dumpster plan correctly states that the dumpster enclosure is to be placed in accordance with City Standard Drawing B-99007. The detail shows exterior dimensions for the enclosure of 10 feet by 16 feet. The minimum interior dimensions shall be 10 feet by 10 feet. The plan detail should also include a note that "the required gates for the dumpster shall contain long steel rods to drop into the pavement in order to secure the gates in the open and closed positions. Drilled holes (for concrete) or metal sleeves (for asohalt) shall be provided for the locking rods. BUILDING DIVISION Comments: COA 07/08/02 2 , . DEPARTMENTS INCLUDE REJECT 3. At time of permit review, submit signed and sealed working drawings of the proposed construction. 4. Add to all plan view drawings of the site a labeled symbol that represents the location and perimeter of the limits of construction proposed with the subject request. 5. Boiler rooms shall comply with the 2001 Florida Building Code Sections 1005.1,704.1.3.3. 6. Plans shall clearly show all new and existing work. Work not covered under this modification shall be deleted from the plans. PARKS AND RECREATION Comments: None FORESTER/ENVIRONMENT ALIST Comments: None PLANNING AND ZONING Comments: 7. If the scope of the project demands removal of plant material then the new plant material is subject to review and approval of the City Forester / Environmentalist 8. On the site plan, indicate the Canal Easement area. 9. The new location of the dumpster enclosure shall be reviewed and approved by the Engineering Department. 10. Provide accent shrubs at least 24 inches in height along the screen wall of the dumoster enclosure (Chapter 7.5, Article II, Section 5.J.). MWR/elj S:\PlanningISHAREDlWP\PROJECTS\United ForwardIMMSP 02-046\COAdoc 1st REVIEW COMMENTS Minor Modification to Site Plan (VI t{ sk IL Project name: United Forward File number: MMSP 02-046 Reference' 1 st review plans identified as with a Planning and Zoning Department date stamp marking DEPARTMENTS INCLUDE REJECT PUBLIC WORKS - General Comments: None PUBLIC WORKS - Traffic Comments: None UTILITIES Comments: None FIRE Comments: None POLICE Comments: None ENGINEERING DIVISION Comments: 1. The site plan references Sheet A-9 for parking and asphalt details. No Sheet A-9 was provided. 2. The two asphalt typical sections on Sheet A-la indicate one (1) inch and 1- 1/2 inch asphalt thickness. Parking lot minimum thickness is one inch. Please correct discrepancy. 3. The top asphalt typical section indicates a variable width and slope behind the Type "D" curb. A maximum slope of 4: 1 shall be specified. 4. The Type "D" Curb Detail is improperly captioned. This typical is for the Concrete Wheel Ston. 5. Provide calculations showing no net change in required storm water discharge storage for the site. 6. Indicate, by note, that striping shall be placed in accordance with City Standard Drawing B-98001. 1ST REVIEW COMMENTS 06121/02 2 DEPARTMENTS 7. Indicate, by note, that the new dumpster enclosure shall be constructed in accordance with City Standard Drawing B-88007. BUILDING DIVISION Comments: 8. Indicate within the site data the type of construction of the building as defined in Chapter 6 of the 2001 Florida Building Code. 9. Indicate within the site data the occupancy type of the building as defined in Chapter 3 of the 2001 Florida Building Code. 10. Add a labeled symbol to the site plan drawing that represents and delineates the path of travel for the accessible route that is required between the accessible parking spaces and the accessible entrance doors to the building. The symbol, required to be installed along the path, shall start at the accessible parking spaces and terminate at the accessible entrance doors to the building. The symbol shall represent the location of the path of travel, not the location of the detectable warning or other pavement markings. The location of the accessible path shall not compel the user to travel in a drivellane area that is located behind parked vehicles. Identify on the plan the width of the accessible route. (Note: The minimum width required by the code is forty- four (44) inches). Add text to the drawing that would indicate that the symbol represents the accessible route and the route is designed in compliance with Section 4.3 (Accessible Route) and 4.6 (Parking and Passenger Loading Zones) of the Florida Accessibility Code for Building Construction. Please note that at time of permit review, the applicant shall provide detailed documentation on the plans that will verify that the accessible route is in compliance with the regulations specified in the Florida Accessibility Code for Building Construction. This documentation shall include, but not be limited to, providing finish grade elevations along the path of travel. 11. Identify within the site data the finish floor elevation (lowest floor elevation) that is proposed for the/each building. Verify that the proposed elevation is in compliance with regulations of the code by adding specifications to the site data that address the following issues [Section 3107.1.2, Chapter 31 of the 2001 Florida Building Code]: a) The design professional-of-record for the project shall add the following text to the site data. "The proposed finish floor elevation _' _ NGVD is above the highest 100-year base flood elevation applicable to the building site, as determined by the South Florida Water Management District's surface water management construction development regulations." b) From the FIRM map, identify in the site data the title of the flood zone that the building is located within. Where applicable, specify the base flood elevation. If there is no base flood elevation, indicate that on the plans. INCLUDE REJECT t/ / / / 1ST REVIEW COMMENTS 06121/02 3 . DEPARTMENTS INCLUDE REJECT c) Identify the floor elevation that the design professional has established for the building within the footprint of the building that is shown on the drawings titled site plan, floor plan and paving/ drainage (civil plans). 12. On the drawing titled site plan, identify and label the symbol that represents V the property line. 13. As required by Chapter 4, section 7 of the Land Development Regulations, ~ submit a current survey of the subject property. 14. The building plans are not being reviewed for compliance with the applicable V building codes. Therefore, add the words "Floor plan layout is conceptual" below the drawing titled Floor Plan found on sheets A-2 & A-3. 15. As required by Chapter 4, section 7 of the Land Development Regulations, V submit elevation view drawings of the/each building. Dimension on the drawing the overall height of the/each building. The overall height of a building shall be measured from finish grade to the highest point of the roof or parapet wall. 16. Place a note on the elevation view drawings indicating that the wall openings V' and wall construction comply with Table 600 of the 2001 Florida Building Code. 17. At time of permit review, submit signed and sealed working drawings of the V proposed construction. 18. Add to all plan view drawings of the site a labeled symbol that represents the ,,/ location and perimeter of the limits of construction proposed with the subject request. 19. Boiler rooms shall comply with the 2001 Florida Building Code Sections / 1005.1,704.1.3.3. 20. Indicate the type of liquid that will be collected in the sump and discharged to / the drainage system. An interceptor may be required. 21. Plans shall clearly show all new and existing work. Work not covered under V' this modification shall be deleted from the plans. PARKS AND RECREATION Comments: None FORESTER/ENVIRONMENT ALIST 1ST REVIEW COMMENTS 06/21/02 4 DEPARTMENTS INCLUDE REJECT Comments: PLANNING AND ZONING Comments: 22. Provide a revised paving, grading, and drainage plan. (f vi 23. Provide a revised landscape plan. A landscape plan will be required for the it V redeveloped portion of the site. 24. If the scope of the project demands removal of plant material then the new V' plant material is subject to review and approval of the City Forester / Environmentalist 25. On the site plan, indicate the Canal Easement area. V 26. Parking spaces are proposed within the easement area. Prior to the issuance of a permit, the project must obtain authorization from the easement holder V that said parking spaces are permitted within the easement area. 27. In the site plan tabular data, indicate that 54 parking spaces are required V rather than 51 spaces. 28. The new location of the dumpster enclosure shall be reviewed and approved 'V by the Engineering Department. 29. All dumspters shall be screened from public view with a six foot high, V concrete block stuccoed wall. Such enclosure shall have gates (Chapter 9, Section 1O.C.3.). 30. A11 dtlmpsters sflotlld be: placed on it concrcte pad ten (10) fect wide with an- d appropriate depth and bl;: screened on rhrl;:l;: (3)-sitles-. En;l"iQ€ Went shrubs / along the screen wall (Chapter 7.5, Article II, Section 5.J.). ~v\'u.R W ~ 9(1,.0 oJ- 2.41( Wr. 11II'I 31. Place a note on the site plan that all new above ground mechanical equipment / such as exterior utility boxes, meters, and transformers shall be visually screened (Chapter 9, Section 1O.C.4.). Equipment placed on the walls of the building shall be painted to match the building color. 32. On the site plan and floor plan, clearly identify the proposed boiler room ./ addition, including legible dimensions. 33. On the site plan clearly identify all the parking spaces to be eliminated with a V note and dashed area. MWR/sc J:\SHRDATA\PLANNING\SHAREDlWP\FORMS\BLANKS FORMS FOLDER\1ST REVIEW COMMENTSDOC DEPARTMENT OF PUBLIC WORKS ENGINEERING DIVISION MEMORANDUM NO. 02-138 RE: United Forward Fluid Systems Minor Site Plan Modification 2nd Review MMSP 02-046 ( ~- r-~ , I " ['" I.. ~c~~ - !: Iii I@ . -:::,---.J TO: Lusia Galav, Principal Planner, Planning & Zoning FROM: Laurinda Logan, P.E., Civil Engineer DATE: July 2, 2002 '...------. Lusia, Per the request of Sherie Coale, I made a second review of the above referenced revised minor modification plans. It appears all items I noted during my first review have been addressed satisfactorily, however some minor discrepancies still exist. The following items may be addressed (corrected) during the permitting process: o The Parking Detail correctly states that striping is to be placed in accordance with City Standard Drawing 8-98001. The detail shows stall dimensions of 9 ft. x 19 ft. The Standard Drawing specifies 9 ft. x 18 ft. o The dumpster plan correctly states that the dumpster enclosure is to be placed in accordance with City Standard Drawing 8-88007. The detail shows exterior dimensions for the enclosure of 10ft. x 16 ft. The minimum interior dimensions shall be 10ft. x 10ft. The plan detail should also include a note that "the required gates for the dumpster shall contain long steel rods to drop into the pavement in order to secure the gates in the open and closed positions. Drilled holes (for concrete) or metal sleeves (for asphalt) shall be provided for the locking rods." Please let me know if you have any questions regarding my review and comments, or if I can be of further assistance. I can be reached at extension 6482. LUck Xc: Jeff Livergood, P.E., Director, Public Works (via e-mail) Pete Mazzella, Assistant to Director, Utilities H. David Kelley, P.E./P.S.M., Utility Engineer, Engineering (via e-mail) Glenda Hall, Maintenance Supervisor, Parks Ken Hall, Engineering Plans Analyst, Engineering (via e-mail) Frantz LaFontant, Engineering Plans Analyst, Engineering (via e-mail) Sherie Coale, Senior Office Asst., Planning & Zoning C:\My Documents\United Forward Fluid Systems, 2nd Review.doc Project name: United Forward ~\I;cU~. File number: MMSP 02-046 .1 ~ \ft\>>J Reference: 1st review olans identified as with a Planninl! and Zonin!! Deoartment date stamo markl 1'. V ~t> DEPARTMENTS INCLUDE REJE T PUBLIC WORKS - General Comments: None PUBLIC WORKS - Traffic Comments: None UTILITIES Comments: None FIRE Comments: None POLICE Comments: None ENGINEERING DIVISION Comments: 1. The site plan references Sheet A-9 for parking and asphalt details. No Sheet A -9 was provided. 2. The two asphalt typical sections on Sheet A-la indicate one (1) inch and 1- 1/2 inch asphalt thickness. Parking lot minimum thickness is one inch. Please correct discrepancy. 3. The top asphalt typical section indicates a variable width and slope behind the Type "D" curb. A maximum slope of 4: 1 shall be specified. 4. The Type "D" Curb Detail is improperly captioned. This typical is for the Concrete Wheel Stoo. 5. Provide calculations showing no net change in required stormwater discharge storage for the site. 6. Indicate, by note, that striping shall be placed in accordance with City Standard Drawing B-98001. 1st REVIEW COMMENTS Minor Modification to Site Plan 13/~2- ~ ~~ t~ ~ t 1ST REVIEW COMMENTS 06/28/02 2 DEPARTMENTS 7. Indicate, by note, that the new dumpster enclosure shall be constructed in accordance with City Standard Drawing B-88007. BUILDING DIVISION Comments: 8. Indicate within the site data the type of construction of the building as defined in Chapter 6 of the 2001 Florida Building Code. 9. Indicate within the site data the occupancy type of the building as defined in Chapter 3 of the 2001 Florida Building Code. 10. Add a labeled symbol to the site plan drawing that represents and delineates the path of travel for the accessible route that is required between the accessible parking spaces and the accessible entrance doors to the building. The symbol, required to be installed along the path, shall start at the accessible parking spaces and terminate at the accessible entrance doors to the building. The symbol shall represent the location of the path of travel, not the location of the detectable warning or other pavement markings. The location of the accessible path shall not compel the user to travel in a drivellane area that is located behind parked vehicles. Identify on the plan the width of the accessible route. (Note: The minimum width required by the code is forty- four (44) inches). Add text to the drawing that would indicate that the symbol represents the accessible route and the route is designed in compliance with Section 4.3 (Accessible Route) and 4.6 (Parking and Passenger Loading Zones) of the Florida Accessibility Code for Building Construction. Please note that at time of permit review, the applicant shall provide detailed documentation on the plans that will verify that the accessible route is in compliance with the regulations specified in the Florida Accessibility Code for Building Construction. This documentation shall include, but not be limited to, providing finish grade elevations along the path of travel. 11. Identify within the site data the finish floor elevation (lowest floor elevation) that is proposed for the/each building. Verify that the proposed elevation is in compliance with regulations of the code by adding specifications to the site data that address the following issues [Section 3107.1.2, Chapter 31 of the 2001 Florida Building Code]: a) The design professional-of-record for the project shall add the following text to the site data. "The proposed finish floor elevation _' _ NGVD is above the highest 100-year base flood elevation applicable to the building site, as determined by the South Florida Water Management District's surface water management construction development regulations." b) From the FIRM map, identify in the site data the title of the flood zone that the building is located within. Where applicable, specify the base flood elevation. If there is no base flood elevation, indicate that on the plans. INCLUDE REJECT o~v OJ~ Ot~ {Jf-~ 1ST REVIEW COMMENTS 06/28/02 3 DEPARTMENTS c) Identify the floor elevation that the design professional has established for the building within the footprint of the building that is shown on the drawings titled site plan, floor plan and paving/ drainage (civil plans). 12. On the drawing titled site plan, identify and label the symbol that represents the property line. 13. As required by Chapter 4, section 7 of the Land Development Regulations, submit a current survey of the subject property. 14. The building plans are not being reviewed for compliance with the applicable building codes. Therefore, add the words "Floor plan layout is conceptual" below the drawin titled Floor Plan found on sheets A-2 & A-3. 15. As required by Chapter 4, section 7 of the Land Development Regulations, submit elevation view drawings of the/each building. Dimension on the drawing the overall height of the/each building. The overall height of a building shall be measured from finish grade to the highest point of the roof or parapet wall. 16. Place a note on the elevation view drawings indicating that the wall openings and wall construction comply with Table 600 of the 2001 Florida Building Code. 17. At time of permit review, submit signed and sealed working drawings of the proposed construction. 18. Add to all plan view drawings of the site a labeled symbol that represents the location and perimeter of the limits of construction proposed with the subject request. 19. Boiler rooms shall comply with the 2001 Florida Building Code Sections 1005.1,704.1.3.3. 20. Indicate the type of liquid that will be collected in the sump and discharged to the drainage system. An interceptor may be required. 21. Plans shall clearly show all new and existing work. Work not covered under this modification shall be deleted from the plans. PARKS AND RECREATION Comments: None FORESTER/ENVIRONMENT ALIST INCLUDE REJECT tJ 1ST REVIEW COMMENTS 06/28/02 4 DEPARTMENTS INCLUDE REJECT Comments: PLANNING AND ZONING Comments: 22. Provide a revised paving, grading, and drainage plan. 23. Provide a revised landscape plan. A landscape plan will be required for the redeveloped portion of the site. 24. If the scope of the project demands removal of plant material then the new plant material is subject to review and approval of the City Forester / En vironmentalist 25. On the site plan, indicate the Canal Easement area. 26. Parking spaces are proposed within the easement area. Prior to the issuance of a permit, the project must obtain authorization from the easement holder that said parking spaces are permitted within the easement area. 27. In the site plan tabular data, indicate that 54 parking spaces are required rather than 51 spaces. 28. The new location of the dumpster enclosure shall be reviewed and approved by the Engineering Department. 29. All dumspters shall be screened from public view with a six foot high, concrete block stuccoed wall. Such endosure shall have gates (Chapter 9, Section 10.C.3.). 30. All dumpsters should be placed on a concrete pad ten (10) feet wide with an appropriate depth and be screened on three (3) sides. Provide accent shrubs along the screen wall (Chapter 7.5, Article II, Section 5.J.). 31. Place a note on the site plan that all new above ground mechanical equipment such as exterior utility boxes, meters, and transformers shall be visually screened (Chapter 9, Section 10.CA.). Equipment placed on the walls of the building shall be painted to match the building color. 32. On the site plan and floor plan, clearly identify the proposed boiler room addition, including legible dimensions. 33. On the site plan clearly identify all the parking spaces to be eliminated with a note and dashed area. MWR/sc J:\SHRDATA\PLANNING\SHARED\WP\FORMS\BLANKS FORMS FOLDER\lST REVIEW COMMENTS. DOC DEPAR;rv1ENT OF DEVELOPM'ENT Planning~ and Zoning Division Memorandum TO: Laurinda Logan, Tim Large FROM: DATE: RE: Sherie Coale June 28, 2002 United Forward Fluid Systems Please review the attached plans against the 1st review comments (also attached). If you would kindly respond by Wednesday, July 3, it would be much appreciated. .'! DEPARTMENT OF DEVELOPMENT BUILDING DIVISION MEMORANDUM NO. 02-144 TO: Michael W. Rumpf Director of Planning and Zoning FROM: Timothy K. Large ;;::::;;;;;}J5) TRC Member/Building Divis~ DATE: June 21,2002 SUBJECT: Project - United Forward Fluid Systems File No. - MMSP 02-046 15t review We have reviewed the subject plans and recommend that the request be forwarded for Board review with the understanding that all remaining comments will be shown in compliance on the working drawings submitted for permits. BuildinQ Division (Site Specific and Permit Comments) - Timothv K. LarQe (561) 742- 6352 1. Indicate within the site data the type of construction of the building as defined in Chapter 6 of the 2001 Florida Building Code. 2. Indicate within the site data the occupancy type of the building as defined in Chapter 3 of the 2001 Florida Building Code. 3. Add a labeled symbol to the site plan drawing that represents and delineates the path of travel for the accessible route that is required between the accessible parking spaces and the accessible entrance doors to the building. The symbol, required to be installed along the path, shall start at the accessible parking spaces and terminate at the accessible entrance doors to the building. The symbol shall represent the location of the path of travel, not the location of the detectable warning or other pavement markings. The location of the accessible path shall not compel the user to travel in a drive/lane area that is located behind parked vehicles. Identify on the plan the width of the accessible route. (Note: The minimum width required by the code is forty-four (44) inches). Add text to the drawing that would indicate that the symbol represents the accessible route and the route is designed in compliance with Section 4.3 (Accessible Route) and 4.6 (Parking and Passenger Loading Zones) of the Florida Accessibility Code for Building Construction. Please note that at time of permit review, the applicant shall provide detailed documentation on the plans that will verify that the accessible route is in compliance with the regulations specified in the Florida Accessibility Code for Building Construction. This documentation shall include, but not be limited to, providing finish grade elevations along the path of travel. S/Development/Building Code Administrator/TRC/02/United Forward Fluid Systems Page 1 of 2 " 4. Identify within the site data the finish floor elevation (lowest floor elevation) that is proposed for the/each building. Verify that the proposed elevation is in compliance with regulations of the code by adding specifications to the site data that address the following issues [Section 3107.1.2, Chapter 31 of the 2001 Florida Building Code]: a) The design professional-of-record for the project shall add the following text to the site data. "The proposed finish floor elevation _' _ NGVD is above the highest 100- year base flood elevation applicable to the building site, as determined by the South Florida Water Management District's surface water management construction development regulations." b) From the FIRM map, identify in the site data the title of the flood zone that the building is located within. Where applicable, specify the base flood elevation. If there is no base flood elevation, indicate that on the plans. c) Identify the floor elevation that the design professional has established for the building within the footprint of the building that is shown on the drawings titled site plan, floor plan and paving/ drainage (civil plans). 5. On the drawing titled site plan, identify and label the symbol that represents the property line. 6. As required by Chapter 4, section 7 of the Land Development Regulations, submit a current survey of the subject property. 7. The building plans are not being reviewed for compliance with the applicable building codes. Therefore, add the words "Floor plan layout is conceptual" below the drawing titled Floor Plan found on sheets A-2 & A-3. 8. As required by Chapter 4, section 7 of the Land Development Regulations, submit elevation view drawings of the/each building. Dimension on the drawing the overall height of the/each building. The overall height of a building shall be measured from finish grade to the highest point of the roof or parapet wall. 9. Place a note on the elevation view drawings indicating that the wall openings and wall construction comply with Table 600 of the 2001 Florida Building Code. 10. At time of permit review, submit signed and sealed working drawings of the proposed construction. 11. Add to all plan view drawings of the site a labeled symbol that represents the location and perimeter of the limits of construction proposed with the subject request. 12. Boiler rooms shall comply with the 2001 Florida Building Code Sections 1005.1, 704.1.3.3. 13. Indicate the type of liquid that will be collected in the sump and discharged to the drainage system. An interceptor may be required. 14. Plans shall clearly show all new and existing work. Work not covered under this modification shall be deleted from the plans. bf S/DevelopmentlBuilding Code Administrator/TRC/02/United Forward Fluid Systems Page 2 of 2 // DEPARTMENT OF PUBLIC WORKS ENGINEERING DIVISION MEMORANDUM NO. 02-121 TO: FROM: Lusia Galav, Principal Planner, Planning & Zoning Laurinda Logan, P.E., Civil Engine:, ~ June 18, 2002 \. ./' United Forward Fluid Systems ~ Minor Site Plan Modification MMSP 02-046 DATE: RE: Lusia, As requested, I reviewed the above referenced minor modification plan for any engineering comments. offer the following items: o The site plan references Sheet A-9 for parking and asphalt details. No Sheet A-9 was provided. o The two asphalt typical sections on Sheet A-1 a indicate 1 in. and 1 Y:z in. asphalt thickness. Parking lot minimum thickness is 1 in. Please correct discrepancy. o The top asphalt typical section indicates a variable width and slope behind the Type "0" curb. A maximum slope of 4:1 shall be specified. o The Type "0" Curb Detail is improperly captioned. This typical is for the Concrete Wheel Stop. o Provide calculations showing no net change in required stormwater discharge storage for the site. o Indicate, by note, that striping shall be placed in accordance with City Standard Drawing 8-98001. o Indicate, by note, that the new dumpster enclosure shall be constructed in accordance with City Standard Drawing 8-88007. Please let me know if you have any questions regarding my comments, or if I can be of further assistance. I can be reached at extension 6482. LUck XC: Jeff Livergood, P.E, Director, Public Works Pete Mazzella, Assistant to Director, Utilities H. David Kelley, P.E./P.S.M., Utility Engineer, Engineering Glenda Hall, Maintenance Supervisor, Parks Ken Hall, Engineering Plans Analyst, Engineering (e-mail) Frantz LaFontant, Engineering Plans Analyst, Engineering File C:\My Documents\United Forward Fluid Systems, Minor Site Plan Mod..doc o o UF FLUIOSYSTEMS UF Fluid Systems 4020 Thor Dr. Boynton Beach, FL 33426 June 3, 2002 City of Boynton Beach Mr. Michael W. Rumpf Director Planning and Zoning Division 100 E Boynton Beach Blvd Boynton Beach, FL 33426-0310 Dear Mr. Rumpf; We hereby request approval for the "Boiler Room Addition" and minor interior remodeling for the referenced project. The project is shown on the attached plans by Bomfa Architectures dated 06-03-02. Included in the scope is the relocation of the dumpster enclosure, and modification of parking, adding a net amount of 12 spaces. We thank you for your consideration of this matter. A4 Stanley Stripe Plant Manager UF Fluid Systems r~.'--.. t I .JUN L_- 4 r , _.--l C) 'D 4 "3 4 U us 16 00 () r; 110 UF Fluid Systems Inc 4020 Thor Drive Boynton Beach, Florida 33426 Tel 561 7331515 Fax 5617331542 ,. \:l ~ 3 (lJ ~ ~ (lJ Q ro I") o 0- c: -.. :J "'. 1O o III r+ ~ -:i>: ~ o 3 (lJ 9- ~ "'. ...... ::;. lQ ~ ~. c:;:, 0- ~ a} ~ ~. o , o Qj 0. t'0 ~ o g " ~ l> I") ~ Qj 0- iD '" c: 0- ~ ;:;:;: c: ...... O. :::> t\) ro -2 (lJ. 3 ::; ~ in VI c: ~ -.. ~ ~ ~ ro -.. o -.. r- (lJ ~ ::t! Qj ...... :!1 :::>. ",. ,:::>- ~ ~. ;>:J ~ o ~ G) Qj r+ rt> , rt> ::+ ~. m Qj '" r+ m iD < Qj r+ o. :J @ !Xl Qj ~ ::T u. Gl @ '< '-.J V1 :b' ~.. G) o '" '" g' ::l 'ili. 3 :=r s: 8 !d [ c '" r+ ... ~ s: Qj ::f r+ III :J Qj :J n rt> 11 ~ ~. :J 1O '" ;>:J ~ o ~ :J G) Qj r+ rt> J;' Qj 3 rt> '" Vi ~ m Qj ~ m ~ Qj r+ o :J @ , ~ 0.. :J 1O o g " Vl Qj nf ~ if ~ V1 :b' 3 G) [ '" g' :J 'ili ~. :J s: ~ s- o. c ~ ~ s:: ~. :J r+ rt> :J Qj :J n rt> 11 ~. :J 1O '" ;>:J Q. o ~ :J G) Qj r+ rt> '" Vi ~ m Qj '" r+ m iD < Qj r+ o. :J @ [ :J 1O o g " 3! Qj r+ S. c 3 ~ Qj '< '-.J W :b' 3 G) [ g' :J OJ 3 S. s: 8 ib s- o. c s. '!!.. s: Qj S. r+ rt> :J Qj :J n ro 11 ~ ~. :J '5l Vl r+ ~. ;>:J ~ S. 1O VI N ~ m Qj VI r+ Qj :J 0.. ~ ~ r+ m iD ~ r+ o :J VI :2 Qj ~. :J C 3 G'l Q1 '< '-.J W :b' ~. G) [ VI !Xl rt> :J 'ili ~. :J s:: Q !ll S- o.. c ~ Qj. s: Qj S. r+ rt> :J Qj :J n rt> 11 ~ ~. :J '5l :!:> , o c < ~ VI -:i>: ~ m Qj ~ m iD < ~ o :J @ , 1il Q, :J 1O o g " 'Q iiI ~. :J C 3 G'l Q1 '< '-.J W :b' ~. G) o VI VI g' :J 'ili 3 :J :s:: 8 ,ro :f 0. C ~ w. s: Qj 3. r+ III :J Qj :J n rt> 11 o Qj ~. :J 1O VI )> n @ :J .-+ Vl q- ~. m Qj VI ~ ~ ~ Qj :J 0. Z o ;:l ::T m ~ Qj r+ o :J VI o :J '< m ~ ::r lO !Xl C rt> N g ()) , N o s: Qj ;::l: rt> !Xl ~ 'ili. 3 S. :s:: 8 ,ro m ~ ~ Q' G) Q1 ~ o c 3 -s: r+ ~ m :J r\ 0- '" c iD m Qj VI r+ m ~ ~ o. :J @ , o Qj Q, :J 1O o g " ~ ~ ... a.: Qj .~ ::T ;:::i: rt> (0'1 N s: Qj ;::l: rt> cS 3 Qj r+ n ::T rt> x Vi. ~. :J 1O ,. if ~ Qj :J 0. :J 1O , Qj 3 -0 'Q o VI r+ VI -i ::T a c 1O ::T o C r+ ~ ~ ." 0- :J. 0. Qj ~ ::T ;:::i: rt> 11 , ~ N :s:: Qj ;::l: rt> cS 3 Qj r+ n ::T rt> x Vi. ~. :J 1O ,. t ~ 3 Qj -< ." Qj n Qj 0. rt> 11 o o c "" ~ m ~ ~. o :J VI ~ :::; 11 :J. fr ~ ::T ~- (0'1 ~ N 1~ rt> cS 3 Qj r+ n ::T rt> x ~: :J 1O ,. o m VI 11 ;>:J 'Q -i 6 z , o 11 ~ 6 z iD ..., ~ r+ o ~ 1O ~ n o , o c ;>:J VI 'Q m n " n ~ o z ::!:! Z v; :r: ~ Z -i VI 'Q m n " n ~ 6 z m >< -i m ;>:J 5 ;>:J ~ Z -i l/'l 11 I m o C , m ~ ro n o 3 3 u ro ro :J u 0. Qj ~. ~ o (5 :::l :::l Qj '" u ~ u Qj ~ u ~. ~ o CJ C1l OJ VI VI U C1l n =;; ro 0. CJ C1l o _:E Qj :::l '< 3 o 0. ~ n ~ (5 :::l -'" '" c CJ ~ ;=i: g. o :::l '" OJ n n C1l U r+ OJ CJ iD o :J '< C U o :::l 0. rt> '0". 1O :::l ~ OJ :::l 0. o :E :::l ~ OJ U u a < OJ :s:: ~ OJ 3 OJ :::l C ..., OJ o c ~- '" ro n o 3 3 C1l :::l 0. ~. o :::l VI ;>:J C1l 3 o < C1l OJ :J '< 8 VI III 2 ,~ 3 '" n OJ iD ~ o ~. 0. OJ ~ o :::l :E ;:::t: ::::r ~. ro CJ 2 '" ::::r -g C1l '" '" c ro :E OJ '" ::::r OJ :::l 0. U 3 rt> OJ '" U rt> U OJ :::l r+ 3 OJ :J C ..., OJ n r+ C "" ~ VI n o ~ aJ C1l :::l OJ. 3 :::l :s:: o o ro )> n ~ n :s:: Qj '" o :::l -< VI C1l OJ ~ o m m + :::l '" ::::r n o OJ r+ OJ '" ~ n ~ C1l 0. CJ <:Q.. o :E ..., o '!!.. ~ C n n o 3 OJ VI o :::l -< '" c =1., OJ n C1l '" 'Q OJ ~ OJ U u n ~. o :::l CJ '< '" u Q1 '< ~ -- ii iD -"" OJ '" ro .0 ~. ro 0. n OJ ro 3 c ~ CJ C1l r+ Qj " rt> :::l r+ o Qj n ::::r ro < C1l OJ C :::l =;; o 3 n o ~. :::l 1O r+ ::::r n " :::l C1l '" '" z o 0. "" 1:) _VI VI OJ 1O -'" '" r+ ro OJ " -'" ~ CJ c CJ CJ iD ~ ~ 3 0. C1l :E 2 VI r+ '" r+ ~. :::l '" r+ o CJ C1l CJ C1l iD 3 o < rt> 0. U 9. C1l n r+ VI C "" a c :J 0. :J 1O ..., Q. w 1O rt> OJ :J 0. '" ::::r 2 CJ '" Qj VI :::l rt> n rt> '" Kl ~ ?5 ~ "'. ~. '" Qj ::;. '" Qj in o 16 <:: "'. 6' ill ~ C1l ~ ~. ~ tiS. ::::r ~. :::l 1O --h ~. C ro '" OJ :J 0. Qj o o :E :::l VI U o S '" -- n Q. iD n r+ (5 :::l CJ o X C1l '" r+ o ~ u OJ :J r+ C1l 0. o 3 OJ r+ n ::::r :J C1l :E ~ '" tiS :::l C '0". :::l 1O n o 0- c "" VI OJ :::l 0. ..., :J co. ::::r C1l '" ~ n ~ rt> 0. ~ ..., Qj n OJ 0. C1l OJ :::l 0. OJ n n C1l :::l r+ n o 0- c "" '" 3 :E OJ ::::r :::l C1l ~ ro OJ n r+ C ~ r+ ::::r C1l g. VI 1O :::l OJ ro n o n 3 0 3 Q. C1l n :::l OJ ~ it) g" ~. :::l ~ 3 1O OJ C1l :J OJ ~ :::l OJ D. 0 C ~ o 1O o :E C1l ro ro n o ro 3 3 3 o C1l < :::l ro 0. D. OJ ~. ~ 0 o i;; ;;:j ~ o n ~. ~ ::;. (;i 9!.. OJ :::l 0. ::::r o iD '" OJ ro '" <.Q. :::> ~ lQ- :::>- o ~ c> ~. ~ li)' ~ o ,[ 16 ~ c n n o OJ :::l 0. n o 3 l:l iD & ~ 0 n 0 o 1(; ~ n a ~ " {5 ~ ~ '" ro c u ii} Qj m ~ r+ OJ o '" ~ 15 n u C1l ro ~ VI OJ ~ ~ ro :E OJ '" ::::r C1l 0. OJ :J 0. r+ -g. ?5 3 Z ro 0 0. ;:l OJ ::::r '" --h OJ n OJ 0. 1;3 ,C1l :::l r+ ~ VI C "" ..., OJ n C1l u ro u OJ ill ~. o :::l Qj '" u C1l u OJ ~ o C1l VI U C1l n w. '< o :J }> :::l '< 0. '" n ro u OJ :::l n ro '" '" ::::r OJ -i C\ ::::r m C1l Z U m OJ ;>:J g ~ 1O Z n 0 o -i ~ ~ ill n r+ ~ CJ '" C1l ::::r CJ OJ a c :::l \0 r6 ~ ~. o 1O r+ ~ ::::r C1l C1l r+ OJ ::::r ::+ C1l C1l '" :J ;=;: r+ C1l (5 OJ :::l :::l o 0. ..., r+ r+ ::::r ::::r C1l C1l C1l o x :E ~. :::l ~ OJ :J 0. 0. C1l '0" \0 :J ~ :::l \0 n o :::l 0. ;:::t: o :::l '" ~ ~. o CJ rt> ..., o m g. Qj C1l ~ ~ :E OJ o ;:l ~ ~ V). ~ :J ~. :J 1O 16 =1., o 3 C1l 0. ~ C1l X co ~. :::l 1O n o :::l 0. 2: o :::l '" OJ :J 0. 0. 3 rt> :::l '" (5 :::l '" OJ VI OJ u 'Q. n OJ CJ ,C1l '" ::::r OJ CJ rt> < ~ =--=h ro 0. DATE: YOUR NAME: Applicant Name 1ZI 1ZI PRE-APPLICA TION CONTACT QUESTIONS j(v/t17 ~/1 '- Phone # .J-(p ( C/eJ 4- ?4t/- / 1. HAVE YOU SlO~N TO ANY STAFF MEMBER ABOUT THE PROJECT? gyES (ftJ ~ (IF YES HA"\TE THOSE STAFF MEMBERS SCHEDULED FOR THE PRE-APP MEETING.) NAME: DNO LOCATION OF PROPERTY (CROSS STREETS/INTERSECTIONS): 4020 / /zov y{/t~ 2. D 3.WHAT WOULD YOU LIKE TO DO? ~W PROJECT ~BUILDING EXPANSION OR MODIFICATION: D CHANGE IN PRIOR USE? @IS THE STRUCTURE CURRENTL Y VACANT? D VARIANCE TYPE~ D POOL OR SCREEN ENCLOSURE - D COMMERCIAL PROPERTY? D RESIDENTIAL PROPERTY? D INDUSTRIAL PROPERTY? D DO YOU KNOW THE ZONING CODE DESIGNATION? <,--I '.'./ ? 1ZI 4. TIME AND DATE PREFERRED: ~ V c=.J,?->-...-. 1ZI 5. HOW MANY PEOPLE WILL BE AT THE PRE-APP MEETING? NOTE: TELL THE PERSON THAT SOMEONE FROM THE DEPARTMENT WILL CALL THEM BACK TO CONFIRM MEETING. ** PRE-APPLICATION MEETINGS SHOULD BE SCHEDULED FOR A MINIMUM OF ONE (1) HOUR TIME MODULE. ** PRE-APPLICATION MEETINGS SHOULD BE SCHEDULED NO LESS THAN TWO (2) DAYS PRIOR TO DATE/TIME OF MEETING. IF AN URGENCY IS SENSED, DISCUSS WITH MIKE OR LUSIA. ** NO PRE-APPLICATION MEETINGS SHOULD BE SCHEDULED FOR THE FRIDAY BEFORE A SCHEDULED TRC AND P & D BOARD MEETING. ** LUSIA IS NOT AVAILABLE FOR MEETINGS ON TUESDAY MORNINGS. **NO APPOINTMENTS SHOULD BE SCHEDULED ON THURSDAYS BETWEEN 8:30- 10:30 A.M. (PILOTS MEETING) AND MONDAYS BETWEEN 8:30-12:30 A.M. (HERO'S MEETING). UPDATED 02/07/01 nSHROAT A\PLANNINGISHAREDlWPISPECPROJ\PRE.APPLICA TONS LOG-IN FOLDERICONT ACT QUESTIONS FOR APPLICANT DOC .p7, /1'<- I (tI, yi; se- I 7,1/'J7~/ J]of ( hjer-J / fJo-;, fr'~~ ~ PRE-APPLICATION MEETING/TRACKING LOG MEETING DATE: 06/08/0t TIME: 3:00 PM APPLICATIONS: ZONING DISTRICT: M-1 Cool Care Bide PROJECT NAME: United Forward I ATTENDING STAFF: Nancy Byrne, Rodger Kemmer, Edwin Yates, Mike Rumpf ATTENDING AS APPLICANT: Kevin Mushlin, Pavel Rodneyski, Tatiana PHONE: 561-994-9441 FAX: NAME OF APPLICANT/CONTACT: ADDRESS: PHONE: FAX: PROJECT ADDRESS: PROPOSED TYPE OF USE/OCCUPANCY: DATE SUBMITTAL RECEIVED: DATE DENIED: COMMENTS: Tubing Rubber products, Goal: Long time presence in the City Products meet /exceed expectations, requirements Parking seems to be in compliance; applicant aerees to build more if needed. J:\SHRDATA\Planning\SHARED\WP\PROJECTS\United Forward\United Pre-Application Tracking Log.doc .. '" PRE-APPLICATION MEETING LOG MEETING DATE: ~ /""Mda~L APPLICATIONS: ZONING DISTRICT: PROJECT NAME: lJ 1'--1 l,e" f-D' vJA RJ ATTENDING STAFF: ATTENDING AS APPLICANT: PHONE: NAME OF APPLICANT/CONTACT: ADDRESS: PHONE: PROJECT ADDRESS: TIME: ~~ l3 '-' I' ) 1., '" . FAX: FAX: PROPOSED TYPE OF USE/OCCUPANCY: DATE SUBMITTAL RECEIVED: DATE DENIED: COMMENTS: J:\SHRDATA\Planning\SHARED\WP\PROJECTS\PRE APPLICATIONS MEETING LOGS\Pre-Application Meeting Log.doc :- UIJ/T6.D FoR.t.JA~ PRE-APPLICATION MEETING SIGN IN SHEET PLEASE PRINT MEETING DATE: t;/'t/O I TIME: -3 p-r-n . ATTENDING FOR APPLICANT: ~-rv ft1tL~~ NOTICE: The purpose of this conference shall be for the staff and applicant to discuss overall community goals, objectives, policies and codes ass related to the proposed development and to discuss site plan review procedures. Opinions express at the pre-application conference are not binding for formal review purposes. Additional staff comments may be forth coming based on actual lans submitted for review. City of Boynton Beach Attending for Applicant Attendin Staff ~ ,fYD J /Jl;21iu- d/llc~u.fil PAVEL- ROi:)r"~s~ P,'<E S\DSN. r- - i::>Yi)t{(V l'?op~ 0<. ~ -If:lf.- Pi ,ee; f) 1:<t1-r. ~ vJ__ 1::'(,..,.. \.... ....--- ',/ et j ,. Ci.. 7 ,.0.... /Ilcuf kffV//V J/~/3h6;v J~,~:;L' .s(y,&y ~.te. J:\SHRDATA\PLANNING\SHARED\WP\FORMS\PRE-APPL MEETING-SIGN IN SHEET.DOC ~ PROJECT NAME: United'Ii' orward Fluid Systems LOCATION: 4020 Thor Drive PCN: I FILE NO.: MMSP 02-046 II TYPE OF APPLICATION: I AGENT/CONTACT PERSON: Stanley OWNER: Stripe PHONE: Plant Manager, UF Fluid Systems FAX: PHONE: 7331515 ADDRESS: FAX: 7331542 ADDRESS: 4020 Thor Drive Boynton Beach, FL33426 Date of submittal/Projected meetine dates: SUBMITTAL / RESUBMITT AL 6/4/02 1 ST REVIEW COMMENTS DUE: N/A PUBLIC NOTICE: N/A TRC MEETING: N/A PROJECTED RESUBMITTAL DATE: N/A ACTUAL RESUBMITTAL DATE: N/A 2ND REVIEW COMMENTS DUE: N/A LAND DEVELOPMENT SIGNS POSTED N/A (SITE PLANS): PLANNING & DEVELOPMENT BOARD N/A MEETING: COMMUNITY REDEVELOPMENT N/A AGENCY BOARD CITY COMMISSION MEETING: N/A COMMENTS: S:\Planning\SHARED\WP\PROJECTS\United Forward\MMSP 02-046\2002 PROJECT TRACKING INFO.doc