Loading...
REVIEW COMMENTS _)EPARTMENT OF DEVELOPMENT MEMORANDUM NO. PZ 02-158 SITE PLAN REVIEW STAFF REPORT COMMUNITY REDEVELOPMENT AGENCY AND CITY COMMISSION August 6, 2002 DESCRIPTION OF PROJECT Project Name/No.: Vermeer Southeast Sales/ NWSP 02-013. Property Owner: Boynton Industrial Park Association. Applicant/Agent: Mr. Ken Kruger, P.E.. location: Lots 6, 7 and 8 of Boynton Beach Industrial Park North. land Use/Zoning: Light Industrial / M-1. Type of Use: Industrial/Warehouse. Project Size: Site Area: Building Area: First floor: Second floor: Total: Lot Coverage: 4.32 acres (186,179 square feet) 10,222 square feet 4,000 square feet 14,222 square feet 5.4 % Adjacent Uses: (See Exhibit "A" - Location Map) North - Vacant property with an Industrial land use designation and zoned Light Industrial (M-1 ); South - Vacant property with an Industrial land use designation and zoned Light Industrial (M-1); East - C.S.x. Railroad Right-of-Way; and West - West Industrial Avenue right-of-way, farther west are developed single-family homes with a Low Density Residential designation and zoned R-1-A. Site Characteristics: The site is composed of three (3) lots totaling 4.32 acres. The site contains a 32-inch Ficus tree and is predominately vegetated with a variety of overgrown grasses. The City's Forrester / Environmentalist reports that a native scrub habitat may exist along the eastern property line because of an existing gopher tortoise permit for the site. There is no other vegetation of any significance on the site. The subject property is surrounded by other industrial uses, and zoned M-1. Proposal: The developer is proposing to construct a 14,222 square foot building to be located on a vacant 4.32-acre parcel. An "open equipment display" area is proposed at the rear of the building. The building with its related parking will be for a business that services and sells construction machinery (See Exhibit "B" - Proposed Site Plan). Page 2 Vermeer Southeast Sales Site Plan Review Staff Report Memorandum No. PZ 02-158 Concurrency: a. Traffic - A traffic statement for this project was submitted and was sent to the Palm Beach County Traffic Division for their review and approval. The Palm Beach County Traffic Division determined the project is in compliance with the Traffic Performance Standards of Palm Beach County. b. Drainage - Conceptual drainage information was provided for the city's review. The city's concurrency ordinance requires drainage certification at time of site plan approval. The Engineering Division is recommending that the review of specific drainage solutions be deferred to time of permit review. Driveways: The proposed project includes two (2) main points of ingress / egress along West Industrial Avenue. Each entrance would be comprised of a 24-foot wide ingress driveway and a 24-foot wide egress driveway, for a total of 48 feet in width for each. Each point of ingress / egress will have a striped median in the center of the opening to direct vehicular traffic in and out of the subject property. The north entrance will be shared with the project to the north (Lot 9). Collectively, the driveway will be 48 feet in width (24 feet of driveway width on the subject property and 24 feet of driveway width on Lot 9). The south entrance will be shared with the project to the south (Lot 5). Similar to the other driveway, it too will be 48 feet in width (24 feet of driveway width on the subject property in conjunction with 24 feet of driveway width on Lot 5). A cross-access agreement is required between Vermeer Southeast Sales (subject property) and the affected abutting parcels (to the north and south) in order to share the points of ingress / egress as proposed on the site plan. This recommendation is included in Exhibit "C" - Conditions of Approval). Since the project is within the Community Redevelopment Agency boundaries, the required backup distance for parking lot drive aisles can be reduced from 27 feet to 24 feet in width. However, the proposed on-site traffic circulation system includes one (1), two-way drive aisle 35-feet in width. This drive aisle is proposed to extend from the north and south property lines. Driveway circulation is proposed around the entire building. Parking Facility: The parking spaces required for the proposed project have been tabulated based on the ratio of one (1) space per 500 square feet of gross floor area, which is required for manufacturing and industrial uses. A 14,222 square foot building will require a minimum of 29 spaces. The site plan proposes a total of 33 spaces for the proposed use, which included two (2) handicap spaces. All parking spaces excluding the handicap spaces will be dimensioned at least nine (9) feet by eighteen feet (9' x 18'), and will include wheel stops. The proposed project is also providing one (1) 20-foot wide by 57.5-foot long loading area located in the southeastern portion of the site. landscaping: The landscaping of the site will fully meet the code requirements when staff comments are incorporated. The proposed pervious or "green" area is 60,934 square feet or 32.4% of the total site. Four percent (4%) of the Page 3 Vermeer Southeast Sales Site Plan Review Staff Report Memorandum No. PZ 02-158 pervious area will be located within the parking areas. A 50-foot wide drainage easement with a 1 a-foot wide Florida Power & Light easement is located along the western (front) property line. A seven (7) foot wide landscape buffer is proposed east of the aforementioned easement areas. This landscape buffer consists of 15 Crape Myrtle trees and 132 Ixora Nora Grant shrubs to be planted at the base of the trees. The landscape plan will require another layer of colorful groundcover plants (see Exhibit "C" - Conditions of Approval). Along the north, south, and east property lines a five (5) foot wide buffer is provided. These perimeter buffers will have a row of Wax Myrtle and Black Olive trees. The foundation plantings around the building are extensive, exceed code requirements and further enhance the site. The development would be provided with the required amount of perimeter and internal landscaping as required in the Land Development Regulations, Chapter 7.5 Article II. Building and Site Regulations: Building and site regulations will fully meet code when staff comments are incorporated into the permit drawngs. Community Design Plan: The proposed building facade, as viewed from the front (west) elevation (see Exhibit "B"), is standard of the typical one-story steel industrial structures constructed in this M-1 zoning district. The proposed building front fac;ade will have a double door entry with a covered porch facing West Industrial Avenue. The proposed rectangular-shaped building is to be constructed of white metal siding including white overhead doors. These doors are located on the side (south) elevation of the building and will not be visible from West Industrial Avenue. The roof panels, window trims, eaves, and the double door entry will be dark green in color. Signage: The project proposes two (2) signs. One (1) wall sign measuring 42 square feet is proposed on the east facade depicting the company's name, and one (1) freestanding monument sign is proposed depicting the Vermeer logo measuring 64 square feet in area. This monument sign is proposed to be pole mounted and located within the 50-foot wide drainage easement. The proposed wall signs and the freestanding sign comply with sign standards including maximum sign area and height as set forth in the Land Development Regulations, Chapter 21. RECOMMENDATION: The Planning and Zoning Division recommends that this request for site plan approval be approved, subject to the comments included in Exhibit "C" - Conditions of Approval. Staff also recommends that the deficiencies identified in this Exhibit "C" be corrected on the set of plans submitted for building permit. xc: Central File \\CH\MAIN\SHRDATA\Planning\SHAREDlWP\PROJECTS\Vermeer Southeast Sales\NWSP\Site plan staff report. doc Location Map EXHIBIT "A" Vermeer Southeast Sales , I I L_ I-J>~h~p N w~, _ S___J 500 o 500 1000 Feet --- 1H'1 ,m' /1~~ H~i! dl l!l~, t~:t! i< i~i llih l'!l" '~ ~ ":111 ',1' j'."I' {l' ,:hl ~~J~l ~- ;1i 2 Z 8(fl :;:~F ~;~I 8fTlc> ~~~ <O["T][T] :::Jg32 ,,2 '" :Z " M I ru 10) e 8 i~ ~2 c;~ R~ ~~ ~f.! ~; ~" ~~ " .. -~-- -"~~:.-\- -". f~~iL t~r~~f~firf)1f1~:1:~~{1~ I ,J !~~ : : : : , f ' : : ::~': : ~: ~ ,c; f . ;~;' ~\; ; ; : :/~ . : : ; ; ; ; ;~:&;,; ; i~/ ", ~ ~ I. ,\ ~ s ~ i ; ; ~ i ~ ; ~ Ii : l': Atj!i \; A ~~-\., '.' '0 r"" 4 ..( ~. '" Ii t ~ &1 ....'~ '" t...}: . .~, ~",' ~I ." :fl~-"'" .,,-.c:'~, /, , " '"~" I: ~. ;:;. ':':':1;' ' "~'.'':''~'; "~ "~I' 8 . . : !, ; t: ; : ;, I; ii "1:1, ~-.'.~ , " , . / ii' , '.,r: "':1 " , "f ,t.., <" .ti= ". ! , . , =~,f-=i-q ,'':*-. ' , ,-,-~ I. . :r~ 1,:8 ',~/! I' I, '; 1 - '=;T)' "1'-- 'I :;t.''-+ ~ cg . :1.>>.." '. ' .' .' k' ......, II ,: 1 rr-r;\ ~ s:: ~ ~ -,~ "/ t ~ ~ Jii ~ . ' " 1 II" '. ,,(, 1;11 ,~ ~r;;, y-,-,-r,.- - I. H H::" 'd~1 !;~U::ct:::~~::, I: Ii J LN'" t: : ' ~' , ,: I J "b~11 ;: :I:~ f I: ! Ii ,:', I :.t~:. t.:, ',q k ,:,'" I ~~ ; t ~ ; i I .~. l~ ~ I.;: i ~ ~;; i!ii I ; , ~ ~ " I; \ : ,'" I ;;-[", i : {t : /' " "\: ' , ." , '\(~' ;"", II i ~ ~ i !; " (:_ ~. _~__ ; ,_E~i 5 I ~; i}\ I !!;~\s ~iyi;~ i:;f~~t 'i~'-J ' '; ; ; \~ ~ ~ i it;" ~(JN~P~V'l'~~~'/ :; ; ~ ;; ~ 5 ,-. l ,] Ii r : i ~ ;. ~~.. Ii . ; ~ i Ii ~ ~ !' f ; t i:;; f ~ Ii ~ LLnL-.i; '_~ i l:-.....1 ~ i .1 i L_J_-L_~ ~---l- i Uti_ ~ ~ t ~~~ -: -r---r----r-r i 1: i-o;: i .. Ii ~ ~ ~ i Ii i i: Ii ~ i ~.~~~ ,~ om -0 ..., '" ~16 el~ , , , , i!~. 'f nlill,!..~II,lil.lliiliil.HH II"H'~'1'+I'r"~"'1 i!l;H;r:~:i:'~~: ~ , 0 M ", a ~ , I Gl i,'1J I'::; z I~ " . ~ ~ gi ; ~i , ! ~ 3$: s . ; :'f}t 5; ; t E: . I' , , ~_ '0'-- ..------.. , ~ f 5 ~ , i i ~ ;. E g , , 5 ; ~ , , , , ; I J . ; ~ . i . ; Ii ;: ! e e ~ , , . l! I ; l " _.j.. li , . , , , , , , . , _i J<- I - SEABOARD COAST LINE (NOW (AS PER ,._---------1 I I I I ~~~,j)-~;:j~2;7.,: - r.."'--' liB I' ~ ~ ~...O) i "1'" ~ ~ 0 i'~ I ~ I ~ Z Iii 0.1" ~ I....~... ~ I~ ~ ie ml'. ;;Or I ~ II I~ Ib. ~ ,--~- "'==-.::-. zft Oft ~lO j'" fila (j) "" !;' 9 .Jt.fJ It 11;' ~ J.U ..IJ M il -, I i~'~ '111 _ I i ,fHiili ,11 :litJ--J.:~I'I' ~:.~ I ! · ~-~ 1~. I I l J ~: ;:: ' ~-'--=>, ., '~laJi~~'-\". U.i!Jjl i .1; Il I' !i ~-.\II i ~"i e i I I I ~P' i . f~~m' ~,. '!! ,I! C) /~! ,I "j""' ___~hi ~-'{~' ~W1i~ ~ ~~ .~; ~I ~:J HARTER - ADAMS ~ ~r ~ ;~ i ~; P.A. Sf\LE OFFICES AND EOUI~'MENT SERVICE BUILDING VERMEER S,OU TH lAST SAU~S AND SERVICE INC LOTS 6, 7 & 8 WEST INDUSTRIAL AVE. BOYTON BEACH, FLORIDA ARCHITECTS AND PLANNERS 1371) p~~~ 7.W~7-5~ :ff~o_r:"~~~~781l F<iF;~F.~;~W" !HIllU!UU TT.m"'l~ i 111ll!!!!!1Il! ' ~~~Hrm= ;. !!!!II!m!1 il!!I:ii!il!I l!! filII o o 1:- ~' ~ i~ Ii .::-)-.flJ z o 1<;:> 1',0 Ie Ii '~.og ~~:~!!. i~i c~ m j':' ~'< ,,"<il~ <- . r'~.:5' .,., "l :r~O 'a- f(n" It I~ '~~'2. ::1 !;Fi. EXHIBIT "B" Y. -.. =."-'."---.~..--::'" -\ - c-~---~ LAUREL HILLS ~- FOURTH ADDITION (PLAT B~K 23, PAGE 142) ;:;t." ;~ , z'ij ~~N l~~L~c~~~::~~~- ',---.' rI~~~<~~ 19;; \~ r \ ~.l,l r \ J Ii LAUREL HILLS - THIRD ADDITION (PLAT BOOK 23, PAGE 126) , ! i \ \ \ I \'" i \ I I \ \ '1~, ~. z ro ~ t:{ ,.; r o -1 r o -1 r o -1 r o -1 r o -1 z '" '" g ~ ,.; (J) '-.i co to ()1 '" ~ ~~ , , I \ I" I i I \ i I I I I I \ L - -1' -'-- -, I I -t--- .. ---[.----- .' -~.::.--~-=---.--~:=.- ~::...:- " m ~ '''J ~- ". ", .><~ ..:-~;r-- -7'-- ~-.Jl" '\" 'Ntl.l_R_/ (O.1"S,C_S9'11) ~'"'' r.-.sr LIME: (JF 20/4~/4..;/ .-'<14' ". SEABOARD COAST LINE (NOW C.S.X.) RAILROAD R/W (AS PER R/W & TRACT MAP ,~ ~I~ ~8 ~~G~ m~ ~i-~~ ~!~ ~:~ ~ lJtJ) ~e:' :Jit~1 ~~ ~ ~~ -D )" '-';:1 0 8~ c > d~ ~~ r b ~ . () ~ > " " 6 ~ 0 h " R G ::.-1 (;--, ~ " :,-j c, ~, CD h " ~ <: ~ :tJ 't ~ il ~ G '::S h 20 '1) -$3 i3!<; ~ :ij ~ [o;:f ~"a ~~ ~ I~ , l~ !. !g 1 ~ ~ l pf~~-:-:=CCf' -~~ : ;.:Wf 1- ..---llij+ , ~\"11E ~~~~:=~~;d_ i~li~}.rii -- - ~ ,toT, , ~i' ,\ \ I : ,\1 J':: ,.; ~ n \\1~rr~!~{ ~II~_~D ~Ii: 1[1 ,,'..' , I '} , ~ t-., 1:.. i~f~~U~! ~~iJ e ,1' ~~~ii!~;~;..' -- ... ~~.! i~ LtH R ii ,In I s l~ \: . t::-i ~ J:: l.e ' co 1'1 V ,!i ; lj Ii' J \~( II: " ~L ~~l' ::]':.1 If i; .\! i;~t: l nn .\:.:: ;;!~ I :: L --t----c-- - , < lilt II i~ ! r i! . [i~: &~~~. 1: ' ~ i I o t ti ~ 19 _ . ><.' 0 r . ,-(,.,~ JIL- --_~r-"8~ , - ::"'~'.'j-~--,,; I I I I 1 I ii, , , , 9;~~~IO~~~i -I- I I // // (' .0;1:: ~; ~I ;' / / -1'::- " J " ( JLtl-:l:_t~-j-~-- --a" r- Ji 1~ ~ g~ o 8 ~ (JI f r o oj r S r o oj /// '" "- - "i~ ~ _ -- -- ~, , !, ,I __ __ ~ _ _" _ __ /~ ..,.-:;---:.....\O(;~B6L~g:;U~~!.t~~~Nl NOl-39'Z2.W 315.00' SEABOARD COAST LINE (NOW C.S.X.) RAILROAD RjW (AS PER R/W & TRACT MAP I' il Ii -0 o ..., A 5' i~m .~~~~ ~~~~ ~ ~ i ~ .i ~~~ ~ ~ :~~ ~W ~ ~ ~i flr[ -01.. ;!~, I~ ~ " en c: " t -< ~ i!! ,m I ~I~ i ~ mi~ hh ~ ! ~~~ i ~ ~!i~~ ~ii~ o 0 ~~ m. .~t~~ ."~. E ~ g ~ ~ ~ ~ ~ e g ~ ~ 6 b'~ ~ m ~~ ~..."'\t l!l'!l ~u r::i 0(;1 ~ r~~2_;;1 II z ; il~l' i:~ ,. ~ ~I~ !H I;!~r~: : I~!~ ~.- 41 i ~ I" .~- - >> . ~~ ~i: ~ ~~~~ ~;~ om ,~o :~ ,_ m~~m ,. . Ig !$:,~:," "':.. '" " I}N ~ '$ ~ o CD -+ g " < ~ ~ i 2 i " : d ; g I~ ~ d r- I . . ; " ~ " ~ ~ .. ~~ ~ ~ . 15792 RED REEF STAEEr sum: 100 l..AKI: WORT1i. I'l.OAII>>, 334CJ7 (5I1)OI-4Ol!ll JI ~ii Vermeer Southeast Sales & Sarvlce. Inc, VERMEER KENNETlf f{. KRllCiER, PE. CONCEPT SITE PLAN " C~l q (j) -I r'l 7J f:=J [T] ) }"> r o -I o >;;i s:: ~.~ '~r "!I~) ~.: n.'""T>.....<--lli-J ,,~" II ~ I~o' ~ C~_-_L_:.____~.~=~./: __t ~ " J' , ~ IL_~u_ 1 Lm ~ -.1 r o oj o --{"=-~)--- Z "~~"......." ill Q 6~ ~?; Q[SClIlF'liO)~ .-,_._-------- H'r IH' I I. """- t-=--.--~ ~I jb~ ,. ." '" i ~ 5" [), 11 H i r~j -~.: ,I I C , :!i],' ~i~ ~ l: E':~ ~ k ~6i : !i'cJ' f'~ !~ I H: ~ .J._ ~_~j " , 'I , " , :i ! if idl11 t"--I i :==~l==l= ~:~t~r~l , , L .1. r'T" ) 1 1 " '] j! L=- OJ -j " II ~, ~I ~/[~-~ qh!!~!..) " / "---/ " : " J r~ ~~~ I ~~! ~~~ I ~I i~ I ~. ~1 1~1 I I I I ,l .- I <~~I~--~~! : : I!~U;I ~ ~ ~~~~Ni I ~ t:i. ~~ ? ~,J :! fi ~ I I I w"Ufr oS:;JJf ~~~':I ;;:00(1)11 VI ~" ~~: ~~j ~J n . o ] ~~ b ... <II ./ / ~ // <:JJO" .. ,"'";!' ~ ii>O,j ~ ~:,...' -~1t/~~~~~/~~ o /2 / IO~,-~U~.'~7~~~~~M'*s't~"T 315.00' SEABOARD COAST LINE (NOW C.S.X.) RAILROAD R/W (AS PER R/W & TRACT MAP ~~p~~~~~ ~~~ nc ~~~ "'l~~ H~ ~~~~ ,.. ~~ O~~ ,,. .~m~."o~~ "~o S~Q ~~~ " ~ UH I~ ~~~i~~g~o .o~ :!~ ~.g F ~~~ I; ~h~~"h~ >~~ no> ~~ ;;l"''l''z ~; o~ Hi i!i~ ~:i!~-~~QlllQ ~~~ ~ i~ "~~h.~~~ og~ z.. ~~ o~~ ~ ~ ~ ..... ~ ~~~ I~ mm~i~ ~H I m I~ ~~ .. ~ ~ i~W~~~~ ~~ii i ~.~ . 1; p~-g .~ ~ ~~F>~~Jjm~ ~~ <' (; ~gRl ~~~ c~ ~ I~ ,.. m Gl m Z o ~~ .~! ~ii ; d PROPOSED o ~ d ;' ~ ~g BOYNTON BEACH FACIUTY ~ ~ ~ I~ Vermeer Southeast Salel. a ServIce. Inc. - = I ?: g ~ ~ -----,--~-~._----- ~ ._--~--~-~ ~ ~ CONCEPTUAL ENGINEERING PLAN - KENNETlf If. K1?lltiE1?, PE IIJ782 RED REEF STREET SUITE 100 LAKE WORTH. F1.ORIDA 334lS7 (561)- " ~o O.':C:^,,~-;~~ ---- ;:;:J.- ,;:>>~ -':f._'-'c?-..':-____:.. L_ fI.- u__ _n_....._.__...i' ..-----1 ru "t :: l.~ l, / ,J r S c; ~~-e_~r---- Z ~'S7'lV-'~T ~~ ~~ ~~ ......... ~~~-- ..'_'n'_ ;~-_~_,.~=~:.~~"'CCC (Wll2 R<~_~R oon<lQN ~C__C~_~~___ '" ... EXHIBIT "B" s~ -m 1~ ~~ o 2 s~ -2 i~ .~ ~ .4 '4 t~ '4 r-<t '4 --=-~-t=.. ~~--='_:'- ~-I--~~ " " ',,' - it Ii I -t~=+=-._----- __no I I ~ ---===t=.~===-==::::=:-+~== ~~~~~I-------'-------I--'._'-- -~~~ , += .4 if it .. I~ > . . . VBM:ER - SALE a=FICE8 AN) SHOP EU..Dt<<1 HARTER - ADAMS P.A. ~ I . . I . . . . . . IlllIIH I!A8l' lEIlIIICE ARCHITI!CTS AND PLANNERS . . . c.u . . LDl8" 7 + I _ NlUBIJIIAL A....1amltl ~ R.alDA 1m .. IfMIt .,..aIL....... ....... .... 40J If.,..._ ,aI..., ..y...... EXHIBIT "e" Conditions of Approval Project name: Vermeer Southeast Sales File number: NWSP 02-013 R fi 2nd l' h J 1 23 2002 PI &Z . d ki e erence: reVIew p ans WIt a uly , anmng omng ate stamp mar ng. DEPARTMENTS INCLUDE REJECT PUBLIC WORKS- General Comments: None PUBLIC WORKS- Traffic Comments: 1. The shared driveway between the noted lots shall be declared in permanent agreement(s) for both properties. The agreement(s), at a minimum, shall define the ownership and maintenance responsibilities of the driveway(s). Copy(s) of the "Shared Driveway" agreement(s) shall be provided at the time of permitting. UTILITIES Comments: 2. Fire flow calculations will be required demonstrating the City Code requirement of 1,500 g.p.m. as stated in the LDR, Chapter 6, Article IV, Section 16, or the requirement imposed by insurance underwriters, whichever is greater (see CODE, Section 26-l6(a)). In addition, the LDR Chapter 6, Article IV, Section 16 requires that all points on each building be within 200 feet of an existing or proposed fire hydrant. Please demonstrate that the plan meets this condition, by showing all hydrants. FIRE Comments: None POLICE Comments: None ENGINEERING DIVISION Comments: 3. Explain "South Line Lot 4. . ." and "North Line Lot 5 . . ." notes shown in the interior of Lot 7. 4. Provide all information on the drainage plan in accordance with the LDR, Chapter 4, Section 7.F. Inadequate grade information has been provided to Conditions of Approval 2 DEPARTMENTS INCLUDE REJECT evaluate flow patterns in the parking lot. At the time of permitting, existing and proposed grades need to be shown around the site and details provided of the typical section(s) for the aisles and proposed swales. 5. At time of permitting it may be necessary to replace or relocate large canopy trees adjacent to light fixtures to eliminate future shadowing on the parking surface (LDR, Chapter 23, Article II, Section A.l.b). 6. Landscaped areas shall be protected from vehicular encroachment by a continuous, raised curb (LDR, Chapter 7.5, Article II, Section 5,A. and Chapter 22, Article II, Section E.) At time of permitting. 7. At time of permitting add a note to the landscape plan that within the sight triangles there shall be an unobstructed cross-visibility at a level between 2.5 feet and 6 feet above the pavement (LDR, Chapter 7.5, Article II, Section 5.H.). 8. The LDR, Chapter 4, Section 7.C.l requires the site plan and landscape plan to be at the same scale. The preferred scale is 1" = 30' . 9. The note stating that 1 00% irrigation coverage will be provided conflicts with the proposed use of the back of the lot as Open Equipment Storage. Please resolve conflict at time of permitting. 10. On the site and civil plans, show and identify all necessary traffic control devices such as stop bars, stop signs, double yellow lane separators striping, directional arrows and "Do Not Enter" signage, etc. Delineate and stripe the "Loading Area" (where applicable - LDR, Chapter 2, Section II.J); include a pavement message in yellow indicating "No Parking - Loading Zone". See City Standard Drawings B-9800 1 and B-900 13 for striping details. At time of permitting. 11. At time of permitting provide written and graphic scales on all sheets. 12. Placement of fill will require an excavation & fill permit. The excavation & fill permit may be obtained prior to final site plan approval through the Building Department. A surety may be required as a condition of the permit approval. At time of permitting. 13. A copy of the consumptive use permit (through the SFWMD) will be required to be provided during the site permitting process. BillLDING DIVISION Comments: 14. Identify the floor elevation that the design professional has established for the building within the footprint of the building that is shown on the drawings titled site plan, floor plan and paving! drainage (civil plans). , DEPARTMENTS INCLUDE REJECT 15. At time of permit review, provide a completed and executed City of Boynton Beach Unity of Title form. The form shall describe all lots, parcels or tracts combined as one lot. A copy of the recorded deed with legal descriptions, of each property that is being unified, is required to be submitted to process the form. The property owner that is identified on each deed shall match. 16. At time of permit review, submit signed and sealed working drawings of the proposed construction. 17. At time of permit review, submit for review an addressing plan for the proj ect. 18. A recorded copy of the Shared Access Agreement for lots 9 and 6-8, and lots 5 and 6-8 shall be submitted to the Building Division at the time of permit application. PARKS AND RECREATION Comments: None FORESTER/ENVIRONMENTALIST Comments: 19. The applicant must show on the landscape plan the replacement trees for the existing 32-inch Ficus tree that will be removed from the site. These additional native trees should be shown with an appropriate symbol on the landscape plan. 20. There may exist native scrub habitat along the Eastern property perimeter that must be preserved as part of an existing gopher tortoise permit for the site. The Bahia sod or seed shown on the landscape plan may not be permitted in conjunction with the gopher tortoise permit. The applicant should address this with a statement on the landscape plan in consultation with the City Forester and an environmental consultant for the owner. PLANNING AND ZONING Comments: 21. The tabular data on the site plan shall include the maximum height allowed in the M 1 zoning district. 22. The landscape plan should show the location of all outdoor freestanding lighting structures. Provide a detail of the proposed outdoor lighting structure(s), including the dimensions, color, and material. Provide the same type of information if wall packs are to be used. 23. Landscaping at project entrances shall contain a minimum of one (1) "signature tree" on both sides of the entrances (Chapter 7.5, Article II, Section 5.N.). Note that signature trees do not contribute toward the total Conditions of Approval 4 DEPARTMENTS INCLUDE REJECT number of required perimeter trees or parking area interior landscaping. Provide one (1) additional signature tree, such as Yellow Elder, Tibouchina granulose, or Bougainvillea at each side of the project entrance. These signature trees shall have a minimum of six (6) feet of clear trunk to preserve the sight area. 24. The landscape buffer adjacent to West Industrial A venue shall contain another layer of plant material. This layer of plant material shall be a combination of colorful groundcover plants and a minimum of two colorful shrub species planted in a continuous row. 25. All above ground mechanical equipment such as exterior utility boxes, meters, and transformers proposed in front of the building shall be visually screened (Chapter 9, Section 1O.CA). Equipment placed on the walls of the building shall be painted to match the building color. 26. Add location of sign to landscape plan and show at base of the monument sign enhanced with colorful groundcover plants and a minimum of two (2) colorful shrub species (Chapter 7.5, Article II, Section 5.0.). 27. Correct inconsistency between pages 1 (Concept Site Plan) and LP-l (Landscape Plan) regarding the footprint! square footage of the proposed building. Page LP-l shows a building footprint of 10,000 square feet while page 1 shows 10,222 square feet. 28. Provide an improved representation of the proposed monument sign with the company logo, including the height dimension above grade as well as above road grade, total signage area and materials / colors which accurately show the appearance in order to confirm architectural compatibility with the building. The maximum allowable signage area is 64 square feet on each side. In addition, clearly identify the site address at the top of the monument SIgn. 29. Provide an improved representation of the proposed wall sign along the west elevation with calculation methodology, including total signage area and materials / colors. If more than one logo exist for the company, provide the details for each logo. ADDITIONAL COMMUNITY REDEVELOPMENT AGENCY BOARD CONDITIONS Comments: 1. To be determined. DEPARTMENTS INCLUDE REJECT ADDITIONAL CITY COMMISSION CONDITIONS Comments: 1. To be determined. " S:\Planning\SHARED\\I\IP\PROJECTS\Vermeer Southeast Sales\NV\6P 02-013\Condition of Approval 2 page revised 2002 brm,doc DEPARTMENT OF PUBLIC WORKS ENGINEERING DIVISION MEMORANDUM NO. 02-127 TO: FROM: Michael W. Rumpf, Director of Planning and Zoning Laurinda Logan, P.E., Civil Engineer ~ June 19,2002 \ \......,..! Standard Review Comments ~, . i New Site Plan - 1 st Review Vermeer Southeast Sales File No. NWSP 02-013 DATE: RE: The above referenced Site Plans, forwarded on 6//07/02, were reviewed against the appropriate requirements outlined in the City of Boynton Beach Code of Ordinances (available on-line at www.cLbovnton-beach.fl.us). Following are the comments with the appropriate Code and Land Development Regulations (LOR) referenced. / PUBLIC WORKS - GENERAL / Code Requirements 1. City Ordinance (CODE, Chapter 10) requires that arrangements be made with the Public Works Department (561-742-6200) for waste disposal associated with this site plan. Confirm, in writing, that arrangements have been made regarding access to the dumpster enclosure inside the proposed gate(s). 2. A minimum dumpster pad is required measuring 10ft x 10ft (inside dimension - including gates). (LOR, Chapter 7.5, Article II, Section 5.J and Article III, Section 9.A.9.a) 3. Indicate, by note, the site dumpster enclosure is to be constructed in accordance with City Standard A-8807. The dumpster will be supplied by Public Works (561-742-6200). 4. Indicate, by note, the required gates for the dumpster shall contain long steel rods to drop into the pavement in order to secure the gates in the open and closed positions. Drilled holes (for concrete) or metal sleeves (for asphalt) shall be provided for the locking rods. 5. Walls for the enclosure shall be provided on three sides and are to be a minimum of 6 ft high and shall be CBS construction with a finish matching that of the adjacent building(s). Accent shrubs shall be provided along the screen wall(s) (LOR, Chapter 7.5, Article II, Section 5.J, Section 5.J and Article III, Section 9.A.9.a, and Chapter 9, Section 10.C.3) Dept. of Public Works, Engin~ing Division Memo No. 02-127 RE: Vermeer Southeast Sales, New Site Plan - 1 st Review, NWSP 02-013 June 19, 2002 Page 2 PUBLIC WORKS - TRAFFIC ~ Code Requirements 1. Per previous discussions shared driveway(s) will be permitted between Lots 6, 7, & 8 and Lot 9, and Lots 6, 7 & 8 and Lot 5. The proposed driveway(s) shall be 48 ft. wide and centered on the property line, allowing 24 ft. (2-12 ft. lanes) driveways for each property should separation be required or desired in the future. 2. Striping configurations do not need to mirror the above noted symmetry. Ingress and egress lanes may be striped as necessary to reflect current needs. 3. The shared driveway between the noted lots shall be declared in permanent agreement(s) for both properties. The agreement(s), at a minimum, shall define the ownership and maintenance responsibilities of the driveway(s). Copy(s) of the "Shared Driveway" agreement(s) shall be provided prior to issuance of any building permits. ENGINEERING,. Code Requirements 1. Add a general note to the Site Plan that all plans submitted for specific permits shall meet the City's Code requirements at time of application. These permits include, but are not limited to, the following: paving, drainage, curbing, site lighting, landscaping and irrigation. Permits required from other permitting agencies such as Florida Department of Transportation (FOOT), South Florida Water Management District (SFWMD), Lake Worth Drainage District (LWDD), Florida Department of Environmental Protection (FDEP), Palm Beach County Health Department (PBCHD), Palm Beach County Engineering Department (PBCED), Palm Beach County Department of Environmental Resource Management (PBCDERM) and any others, shall be included with the permit request. 2. Show zoning and land use on Site Characteristics Map (Survey) (LOR, Chapter 4, Section 7.A.) Explain "South Line Lot 4 . . ." and "North Line Lot 5 . . ." notes shown in the interior of Lot 7. 3. Show all existing utilities on Site Characteristics Map (Survey) and Site Development plan (LOR, Chapter 4, Section 7.A.3). 4. Provide all information on the Drainage Plan in accordance with the LOR, Chapter 4, Section 7.F. Inadequate grade information has been provided to evaluate flow patterns in the parking lot. Existing and proposed grades need to be shown around the site and details provided of the typical section(s) for the aisles and proposed swales. '....w Oept. of Public Works, Engineering Oivision Memo No. 02-127 RE: Vermeer Southeast Sales, New Site Plan _1st Review, NWSP 02-013 June 19, 2002 Page 3 5. Show on the Site and Landscape plans the proposed site lighting (LOR, Chapter 4, Section 7.B.4.) The lighting design shall provide a minimum average light level of one foot-candle. On the Lighting Plan, specify that the light poles shall withstand a 140 MPH wind load (per current Building Codes). Add a note that the fixtures shall be operated by photo-electrical control and are to remain on until 2:00 a.m. (LOR, Chapter 23, Article II, Section A.1.a.) Artificial lighting used to illuminate any property shall be directed away from all residential districts. 6. A Lighting Plan including photometrics, pole wind loading, and pole details in conformance with the LOR, Chapter 6, Article IV, Section 11, Chapter 23, Article I, Section 5.B.7 and Chapter 23, Article II, Section A will be required at the time of permitting. If possible please provide this information as part of your TRC plan submittals - it is much easier to identify and correct any deficiencies now than while you are waiting on a permit! 7. It may be necessary to replace or relocate large canopy trees adjacent to light fixtures to eliminate future shadowing on the parking surface (LOR, Chapter 23, Article II, Section A.1.b). 8. Landscaped areas shall be protected from vehicular encroachment by a continuous, raised curb (LOR, Chapter 7.5, Article II, Section 5.A. and Chapter 22, Article II, Section E.) 9. Indicate, by note, that catch basin and manhole covers shall be bicycle proof (LOR, Chapter 6, Article IV, Section 5.A.2.f). 10. Revise the parking detail to reflect the stall dimensions of 10ft. x 20 ft. and 10ft. x 22 ft. as shown on the site plan. 11. Sidewalks adjacent to parking lots shall be continuous through all driveways and shall be 6 in. thick within driveways (LOR, Chapter 23, Article II, Section P). 12. Depict sight triangles on the Site and Landscape Plans (LOR, Chapter 7.5, Article II, Section 5.H.) 13. Add a note to the Landscape Plan that within the sight triangles there shall be an unobstructed cross-visibility at a level between 2.5' and 6' above the pavement (LOR, Chapter 7.5, Article II, Section 5.H.). 14. The LOR, Chapter 4, Section 7.C.1 requires the Site Plan and Landscape Plan to be at the same scale. The preferred scale is 1" = 30'. 15. The note stating that 1 00% irrigation coverage will be provided conflicts with the proposed use of the back of the lot as Open Equipment Storage. Please resolve conflict. 16.0elineate the equipment storage area on all plans and indicate that the area shall be screened (LOR, Chapter 2, Section 7.E.1). Dept. of Public Works, Engin'eering Division Memo No. 02-127 RE: Vermeer Southeast Sales, New Site Plan - 1 sl Review, NWSP 02-013 June 19, 2002 Page 4 17. On the Site and Civil plans, show and identify all necessary traffic control devices such as stop bars, stop signs, double yellow lane separators striping, directional arrows and "Do Not Enter" signage, etc. Delineate and stripe the "Loading Area" (where applicable - LOR, Chapter 2, Section 11.J); include a pavement message in yellow indicating "No Parking - Loading Zone". See City Standard Drawings B-98001 and B-90013 for striping details. Recommendations/Corrections 1. Indicate to what standard the project is to be constructed; if the FOOT Standard Specifications for Road & Bridge Construction and Standard Index are to be used - the 2000 Specifications are recommended since they contain both English and Metric units. 2. Provide written and graphic scales on all sheets. 3. Staff recommends that the handicap signs be placed in the landscaped area to eliminate potential pedestrian conflict. 4. Placement of fill will require an Excavation & Fill permit. The Excavation & Fill permit may be obtained prior to final site plan approval through the Building Department. A surety may be required as a condition of the permit approval. 5. A copy of the Consumptive Use Permit (through the SFWMD) will be required to be provided during the site permitting process. UTILITIES / Code Requirements 1. No utility plan was included with this submittal, therefore the Utilities Department considers this plan incomplete as submitted. However, since this proposed development is located where utility support is available, we are providing only a cursory review of the plan as submitted. 2. Palm Beach County Health Department permits may be required for the water and sewer systems serving this project (CODE, Section 26-12). 3. Fire flow calculations will be required demonstrating the City Code requirement of 1,500 g.p.m. as stated in the LOR, Chapter 6, Article IV, Section 16, or the requirement imposed by insurance underwriters, whichever is greater (see CODE, Section 26-16(a)). In addition, the LOR Chapter 6, Article IV, Section 16 requires that all points on each building be within 200 feet of an existing or proposed fire hydrant. Please demonstrate that the plan meets this condition, by showing all hydrants. Dept. of Public Works, Engin~ring Division Memo No. 02-127 RE: Vermeer Southeast Sales, New Site Plan - 1st Review, NWSP 02-013 June 19, 2002 Page 5 4. The CODE, Section 26-34(E) requires that a capacity reservation fee be paid for this project either upon the request for the Department's signature on the Health Department application forms or within 30 days of site plan approval, whichever occurs first. This fee will be determined based upon final meter size, or expected demand. 5. Comprehensive Plan Policy 3.C.3.4. requires the conservation of potable water. City water may not, therefore, be used for irrigation where other sources are readily available. 6. Appropriate backflow preventer(s) will be required on the domestic water service to the building, and the fire sprinkler line if there is one, in accordance with the CODE, Section 26- 207. LUck Cc: Jeff Livergood, P.E., Director, Public Works Pete Mazzella, Assistant to Director, Utilities H. David Kelley, Jr., P.E./ P.S.M., Utility Engineer, Engineering Glenda Hall, Maintenance Supervisor, Parks Larry Quinn, Solid Waste Manager, Public Works Ken Hall, Engineering Plans Analyst, Engineering (via e-mail) File C:\My Documents\Vermeer Southeast Sales 1st Review.doc ----' CITY OF BOYNTON BEACH, FLORIDA INTER-OFFICE MEMORANDUM TO: Michael W. Rumpf DATE: Dir. of Planning & Zoning 6/18/02 FILE: NWSP 02-013 FROM: Off. John Huntington Police Department CPTED Practitioner SUBJECT: Vermeer Southeast Sales REFERENCES: Site Plans ENCLOSURES: I have viewed the above building plans and have the following comments: 1. Show traffic flow pattern on site plan. 2. Show placement of Stop Sign(s) at exit onto West Industrial and parking lot exit. 3. Show placement of parking lot and or exterior building lights. TF..C Memorandum Page 1 of 2 ----- Coale, Sherie From: Hallahan, Kevin Sent: Tuesday, June 18, 2002 12:02 PM To: Coa~,Sherie Cc: Galav, Lusia; Johnson, Eric Subject: 02-Plan.doc Planning Memorandum: Forester I Environmentalist To: Lusia Galav, Principal Planner From: Kevin J. Hallahan, Forester 1 Environmentalist Subject: Vermeer Southeast Sales New Site Plan, 1 st Review NWSP 02-013 Date: June 18,2002 Existing trees The applicant must show on the landscape plan the replacement trees for the existing 32-inch Ficus tree that will be removed form the site. These additional native trees should be shown with an appropriate symbol on the landscape plan. There may exist native scrub habitat along the Eastern property perimeter that must be preserved as part of an existing gopher tortoise permit for the site. The Bahia sod or seed shown on the landscape plan may not be permitted in conjunction with the gopher tortoise permit. The applicant should address this with a statement on the landscape plan in consultation with the City Forester and an environmental consultant for the owner. Landscape Plan · All trees noted on the plant list must be a minimum of 12' height and 3-inches in diameter at time of planting. · The plan does not show the City "signature trees" required at the ingress I egress sites. · The plan does not show the 7-foot wide landscape buffer strip along the adjacent public right- of-way. . The tree list meets the 50% native species requirement. Irrigation There is an irrigation system design note on the landscape sheet. 6/18/2002 TRC Memorandum Page 2 of 2 The project should continue in the normal review process. Xc; Eric Johnson, Planner Kjh file 6/1812002 TO: THRU: FROM: RE: Date: PARKS DEPARTMENT MEMORANDUM #02-39 Michael Rumpf, Director of Planning & Zoning John Wildner, Parks Director 9'fJ Barbara J. Meacham, Parks & Landscape Planner ~(}Y1 Vermeer Southeast Sales June 17, 2002 1 . No Comment. JJ4 I 8 2002 ''.o._~.._~...,._-- . I ! \ - , '~~.:'.~ (' /' CITY OF BOYNTON BEACH Fire and Life Safety Division 100 East Boynton Beach Blvd. P.O. Box 310 Boynton Beach, Florida 33425-0310 SITE PLAN REVIEW COMMENTS , For review of: NWSP 02-013 1st review-fire Vermeer Southeast Sales 1060 W. Industrial Ave. Project Name or Address: Reviewed by: Rodger Ke~ Fire Plans Examiner/Fire Inspector Department: Fire and Life Safety Phone: (561) 742-6753 Sherie Coale by email on 06/1 ~2 Comments to: CODE REQUIREMENTS Design documents shall demonstrate compliance with LDR Chapter 6, Section 16, which provides requirements for hydrants. Hydrants in commercial applications shall be no more than 300 ft. apart and the remotest part of any structure shall be no more than 200 ft. from a hydrant. Connections shall be to mains no less than 6 inches in diameter. In addition to domestic requirements at a residual pressure of not less than 20 psi, a fire flow of at least 1500 gpm is required. Design documents where underground water mains and hydrants are to be provided, must demonstrate that they will be installed, completed, and in service prior to construction work per the F/orida Fire Prevention Code, (2000) Section 29-2.3.2. Pursuant to City Ordinance 9-3F, the Fire Marshal has developed an Administrative Order dated May 9, 2001 that provides the minimum performance for all security gates and emergency access. (Copy attached) r Emergency access shall be provided at the start of a project and be maintained throughout construction per the F/orida Fire Prevention Code, Section 3-5, and NFPA 241, (1996) Safeguarding Construction, A/teration, and Demo/ition Operations, Section 5-4.3. City Ordinance Section 9-6, 3. /7-11 requires approved automatic fire sprinkler systems throughout all buildings or structures regardless of the type of construction that are in excess of 12,000 square feet per floor. cc: S. Gale, Fire Marshal B. Borden, Deputy Fire Marshal , ... - - .II> /' DEPARTMENT OF DEVELOPMENT BUILDING DIVISION MEMORANDUM NO. 02-132 (supercedes 02-130) FROM: Michael W. Rumpf Director of Planning and Zoning ~ , ------- , Timothy K. Large ~/ TRC Member/Building DiviS~ TO: Project - Vermeer Southeast Sales File No. - NWSP 02-013 /ll /I~' 'i /11'/;'/ i Ii -: l:,/ ,1 ('1... <' DATE: June 12, 2002 SUBJECT: ~, '."",-ollt. ':' ''''''~'i' <~ We have reviewed the subject plans and recommend that the request be forwarded for Board review with the understanding that all remaining comments will be shown in compliance on the working drawings submitted for permits. Buildina Division (Site Specific and Permit Comments) - Timothv K. Larae (561) 742- 6352 1. Add to the building that is depicted on the drawing titled site plan a labeled symbol that identifies the location of the handicap accessible entrance doors to the building. Florida Accessibility Code for Building Construction, Section 4.1.2, 4.3. 2. On the floor plan drawings, add a labeled symbol that identifies the location of the handicap accessible entrance doors to the building. The location of the doors shall match the location of the accessible entrance doors that are depicted on the site plan drawing. Florida Accessibility Code for Building Construction, Section 4.1.2, 4.3. 3. Identify within the site data the finish floor elevation (lowest floor elevation) that is proposed for the building(s). Verify that the proposed elevation is in compliance with regulations of the code by adding specifications to the site data that address the following issues [Section 3107.1.2, Chapter 31 of the 2001 Florida Building Code]: a) The design professional-of-record for the project shall add the following text to the site data. "The proposed finish floor elevation _' _ NGVD is above the highest 100- year base flood elevation applicable to the building site, as determined by the South Florida Water Management District's surface water management construction development regulations." b) From the FIRM map, identify in the site data the title of the flood zone that the building is located within. Where applicable, specify the base flood elevation. If there is no base flood elevation, indicate that on the plans. c) Identify the floor elevation that the design professional has established for the building within the footprint of the building that is shown on the drawings titled site plan, floor plan and paving/ drainage (civil plans). S/Development/Building Code Administrator/TRC/02/Vermeer Southeast Sales ~. . 4. On the drawing titled site plan, identify and label the symbol that represents the property line. 5. The building plans are not being reviewed for compliance with the applicable building codes. Therefore, add the words "Floor plan layout is conceptual" below the drawing titled Floor Plan found on sheet A-1. However, add to the floor plan drawing a labeled symbol that identifies the location of the handicap accessible entrance doors to the building. The location of the doors shall match the location of the accessible entrance doors that is depicted on the site plan drawing. 6. Add all proposed easements. The location, type and size of the easement(s) shall be shown and identified on the site plan. Where applicable, amend the plans so that structures do not encroach into an easement. 7. Place a note on the elevation view drawings indicating that the wall openings and wall construction comply with Table 600 of the 2001 Florida Building Code. 8. On the site plan, indicate within the footprint of the building(s) the number of stories that are in the building including, where applicable, mezzanines. Also, add to the site data the number of stories in the building including identifying mezzanines, where applicable. Indicate the overall height of the building within the site data. The overall height of the building shall not exceed the height limitations of the Zoning Code. 9. On all floor plan drawings, indicate within the footprint of the building the number of stories that are in the building including, where applicable, mezzanines. 10. Identify on the site plan drawing the actual distance that the building is set back from the north, east, south and west property lines. Please note that overhangs, covered walkways, canopies, awnings or other appurtenances that are attached to the building shall be considered when identifying building setbacks. Therefore, identify the width of the proposed overhangs, covered walkways, canopies, awnings, and/or other roofed areas that extend out beyond the main walls of the building. The building setbacks shall comply with setback regulations specified in the Zoning Code. 11. At time of permit review, provide a completed and executed City of Boynton Beach Unity of Title form. The form shall describe all lots, parcels or tracts combined as one lot. A copy of the recorded deed with legal descriptions, of each property that is being unified, is required to be submitted to process the form. The property owner that is identified on each deed shall match. 12. At time of permit review, submit signed and sealed working drawings of the proposed construction. 13. At time of permit review, submit for review an addressing plan for the project. 14. Add to all plan view drawings of the site a labeled symbol that represents the location and perimeter of the limits of construction proposed with the subject request. S/Development/Building Code Administrator/TRC/02/Vermeer Southeast Sales 2 ..... ..... .. 15. A recorded copy of the Shared Access Agreement for lots 9 and 6-8, and lots 5 and 6-8 shall be submitted to the Building Division at the time of permit application. 16. The square footage noted on the site data doesn't correlate with the square footage amounts noted within the building footprint. rs S/Development/Building Code Administrator/TRC/02/Vermeer Southeast Sales 3 DEPARTMENT OF DEVELOPMENT BUilDING DIVISION MEMORANDUM NO. 02-130 r FROM: Michael W. Rumpf Director of Planning and Zoning --7'"""'~-":---~' ~(. ".;; ;) , / Timothy K. Large ~~ TRC Member/Building Division - JU [j TO: \.... DATE: June 11, 2002 SUBJECT: Project - Vermeer Southeast Sales File No. - NWSP 02-013 We have reviewed the subject plans and recommend that the request be forwarded for Board review with the understanding that all remaining comments will be shown in compliance on the working drawings submitted for permits. Building Division (Site Specific and Permit Comments) - Timothy K. Large (561) 742- 6352 1. Add to the building that is depicted on the drawing titled site plan a labeled symbol that identifies the location of the handicap accessible entrance doors to the building. Florida Accessibility Code for Building Construction, Section 4.1.2, 4.3. 2. On the floor plan drawings, add a labeled symbol that identifies the location of the handicap accessible entrance doors to the building. The location of the doors shall match the location of the accessible entrance doors that are depicted on the site plan drawing. Florida Accessibility Code for Building Construction, Section 4.1.2, 4.3. 3. Identify within the site data the finish floor elevation (lowest floor elevation) that is proposed for the building(s). Verify that the proposed elevation is in compliance with regulations of the code by adding specifications to the site data that address the following issues [Section 3107.1.2, Chapter 31 of the 2001 Florida Building Code]: a) The design professional-of-record for the project shall add the following text to the site data. "The proposed finish floor elevation _' _ NGVD is above the highest 100- year base flood elevation applicable to the building site, as determined by the South Florida Water Management District's surface water management construction development regulations." b) From the FIRM map, identify in the site data the title of the flood zone that the building is located within. Where applicable, specify the base flood elevation. If there is no base flood elevation, indicate that on the plans. c) Identify the floor elevation that the design professional has established for the building within the footprint of the building that is shown on the drawings titled site plan, floor plan and paving/ drainage (civil plans). S/Development/Building Code Administrator/TRC/02/Vermeer Southeast Sales 4. On the drawing titled site plan, identify and label the symbol that represents the property line. 5. The building plans are not being reviewed for compliance with the applicable building codes. Therefore, add the words "Floor plan layout is conceptual" below the drawing titled Floor Plan found on sheet A-1. However, add to the floor plan drawing a labeled symbol that identifies the location of the handicap accessible entrance doors to the building. The location of the doors shall match the location of the accessible entrance doors that is depicted on the site plan drawing. 6. Add all proposed easements. The location, type and size of the easement(s) shall be shown and identified on the site plan. Where applicable, amend the plans so that structures do not encroach into an easement. 7. Place a note on the elevation view drawings indicating that the wall openings and wall construction comply with Table 600 of the 2001 Florida Building Code. 8. On the site plan, indicate within the footprint of the building(s) the number of stories that are in the building including, where applicable, mezzanines. Also, add to the site data the number of stories in the building including identifying mezzanines, where applicable. Indicate the overall height of the building within the site data. The overall height of the building shall not exceed the height limitations of the Zoning Code. 9. On all floor plan drawings, indicate within the footprint of the building the number of stories that are in the building including, where applicable, mezzanines. 10. Identify on the site plan drawing the actual distance that the building is set back from the north, east, south and west property lines. Please note that overhangs, covered walkways, canopies, awnings or other appurtenances that are attached to the building shall be considered when identifying building setbacks. Therefore, identify the width of the proposed overhangs, covered walkways, canopies, awnings, and/or other roofed areas that extend out beyond the main walls of the building. The building setbacks shall comply with setback regulations specified in the Zoning Code. 11. At time of permit review, provide a completed and executed City of Boynton Beach Unity of Title form. The form shall describe all lots, parcels or tracts combined as one lot. A copy of the recorded deed with legal descriptions, of each property that is being unified, is required to be submitted to process the form. The property owner that is identified on each deed shall match. 12. At time of permit review, submit signed and sealed working drawings of the proposed construction. 13. At time of permit review, submit for review an addressing plan for the project. 14. Add to all plan view drawings of the site a labeled symbol that represents the location and perimeter of the limits of construction proposed with the subject request. bf S/Development/Building Code Administrator/TRC/02Nermeer Southeast Sales 2 VEMEER SOUTHEAST SALES NWSP 02-013 1 st Review Planning June 24,2002 An environmental review permit is required. Apply for an environmental review permit. A traffic impact statement / study shall be required, Provide cross-access agreement between Lot 9 to the north, lot 5 to the south and subject property as intended by the note on the conceptual drainage and site plan sheets, The site plan shows a total of 35 parking spaces. However, the tabular data indicates that 32 parking spaces are provided. Revise the tabular data accordingly, The tabular data on the site plan shall include the maximum height allowed in the M1 zoning district. Provide on the site plan the existing Future Land Use and Official Zoning designation for the adjacent properties to the north, south, east and west. The survey must identify the Official Zoning District and Future Land Use designation for the adjacent properties (Chapter 4, Section A.3.). Show the site triangles for the entrances on the site plan and landscape plan. The site plan and landscape plan should show the location of all outdoor freestanding lighting structures. Provide a detail of the proposed outdoor lighting structure(s), including the dimensions, color, and material. Provide the same type of information if wall packs are to be used. On the elevations, identify the "Front Elevation" to include "West Elevation". Repeat this methodology of compass direction for all building sides. Include a color rendering of all elevations prior to the Technical Review Committee meeting (Chapter 4, Section 7.D,2,), Submit a color sample / swatch of all major exterior fmishes, Each sample and / or elevation shall include the manufacturer's name and color code. All required trees shall be at minimum 12 feet overall height and 3 caliper inches when planted (Chapter 7.5, Article II, Section 5.C.2,). The hedges and shrubs shall be a minimum of 24 inches in height, 24 inches in spread, and planted with tip-to-tip spacing immediately after planting (Chapter 7.5, Article II, Section 5,D,). Service areas and dumpsters shall be screened from view by walls at least six (6) feet high, landscaped with shrubs and/or vines. On the landscape plan show the location of the proposed dumpster, Indicate the materials and color used for the dumpster enclosure (Chapter 9, Section 1O.E.3.). The color of the dumpster enclosure shall match that of the principle structure. On the site plan provide the dimension of the truck holding area, All above ground mechanical equipment such as exterior utility boxes, meters, and transformers, shall be visually screened (Chapter 9, Section 10,CA,), Equipment placed on the walls of the building shall be painted to match the building color. Place a note on the site plan indicating this requirement. Landscaping at project entrances shall contain a minimum of two (2) colorful shrub species on both sides of the entrance and a signature tree (Chapter 7,5, Article II, Section 5,N,), Note that signature trees do not contribute toward the total number of required perimeter trees. The base of the monument sign shall be enhanced with colorful groundcover plants and a minimum of two (2) colorful shrub species (Chapter 7.5, Article II, Section 5.0,). Both proposed entrance drives are measured at 50 feet at the property line. This is greater than the 32 feet permitted by Code. Approval of the Director of Development is required, (Ch, 23, Art, II, H,) Provide an improved representation of the proposed monument sign with the company logo, including the total signage area and materials / colors which accurately show the appearance in order to confirm architectural compatibility with the building. The maximum allowable signage area is 64 square feet on each side. In addition, clearly identify the site address at the top of the monument sign, Provide an improved representation of the proposed wall sign along the west elevation with calculation methodology, including total signage area and materials / colors. Clarify by note or by other mean the "Rip Rap Headwall" on the site plan. The site plan depicts marking/striping on the pavement at both entrances of the proposed project. Please clarify the purpose of such marking/striping, S:\Planning\SHARED\WP\PROJECTS\Venneer Southeast Sales\lst review planning. doc