Loading...
APPLICATION PROJECT NAME: Boynton Beach Cancer Center LOCATION: 2375 West Woolbright Rd PCN: 08-43-45-32-04-134-0000 [FILE NO.: NWSP 03-029 II TYPE OF APPLICATION: I AGENTICONT ACT PERSON: OWNER: Boynton Beach Real Estate, LLC George Gentile ADDRESS: 1 Portage Landing S. Gentile Holloway O'Mahoney & Associates, North Palm Beach, FL 33408 Inc. PHONE: ADDRESS: 1907 Commerce Lane Suite 101 FAX: Jupiter, FL 33458 PHONE: 561-575-9557 FAX: 561-575-5260 Date of submittaVProiected meetin2 dates: SUBMITTAL 1 RESUBMITTAL 12/17/03 1 ST REVIEW COMMENTS DUE: 1/9/04 PUBLIC NOTICE: NIA TRC MEETING: 1/27/04 LAND DEVELOPMENT SIGNS POSTED NIA (SITE PLANS): PLANNING & DEVELOPMENT BOARD 2/24/04 MEETING: COMMUNITY REDEVELOPMENT NIA AGENCY BOARD CITY COMMISSION MEETING: 3/2/04 ~11{g(()~ COMMENTS: S:\Planning\SHARED\WP\PROJECTS\Boynton Beach Cancer Center\NWSP 03-029\2003 PROJECT TRACKING INFO.doc Revised, 2/3/04 City Codes Accessed Via Website www.bovnton-beach.org www.amlegal.comlbovnton beach 11 CITY OF BOYNTON BEACH, FLORIDA PLANNING & ZONING DIVISION SITE PLAN REVIEW APPLICATION FOR FEB 3 2004 NEW SITE PLANS & MAJOR MODIFICATIONS TO EXISTING SITE PLAN Has applicant attended a pre-application meeting? Date This application must be filled out completely, accurately and submitted as an original to the Planning and Zoning Division. TWELVE COMPLETE, sequentially numbered, ASSEMBLED AND STAPLED sets of plans including a recent survey and appropriate fee shall be submitted with the application for the initial process of the Site Plan Review procedure. AN INCOMPLETE SUBMITTAL WILL NOT BE PROCESSI;D. Please print legibly (in ink) or type all information. I. GENERAL INFORMATION 1. Pr~ectName:Boynton Beach Cancer Center (aka Freeman Medical) 2. Property Owner's (or Trustee's) Name: Boynton Beach Real Estate, LLC Address: 1 Portage Landing S, North Palm Beach, FL 33408 (Zip Code) Phone: Fax: 3. Applicant's name (person or business entity in whose name this application is made): N/A Address: (Zip Code) Phone: Fax: If contract purchaser, please attach contract for sale and purchase. 4. Agent's Name (person, if any, representing applicant): George G _ Gp.nti le, FASLA Gentile Holloway O'Mahoney & Associates, Inc. Address: 1907 Commerce Lane. Suite 101, Jupiter, FL 33458 (Zip Code) Phone: 561-575-9557 Fax: 561-575-5260 5. Correspondence to be mailed to agent only; if no agent, then to applicant unless a substitute is specified below:* mail to agent *This is the one address to which all agendas; letters and other materials will be mailed. 6. What is applicant's interest in the premises affected? (owner, buyer, lessee, builder, developer, contract purchaser, etc.) N/A 7. Street address of location of site: 2375 W. Woolbright Road 8. Property Control #(PCN) 08-43-45-32-04-134-0000 9. Legal description of site: see attachment 10. Intended use(s) of site: medical office 11. Architect: Everett Jenner 12. Landscape Architect: George G. Gentile 13. Site Planner: Everett Jenner 14. Engineer: GGB Enqineerinq. Gary Bloom 15. Surveyor: FRS and Associates 16. Traffic Engineer: Yvonne Ziel 17. Has a site plan been previously approved by the City Commission for this property? Yes, July 18. 2000 II. SITE PLAN The following information must be filled out below and must appear, where applicable, on all copies of the site plan. 1. Land Use Category shown in the Comprehensive Plan: Office Commercial 2. Zoning District: C-1 , Office & Professional District 3. Area of Site 0.39 acres 16.946 sq. ft. 4. Land Use -- Acreage Breakdown: a. Residential, including 0 acres 0 % of site surrounding lot area of grounds b. Recreation Areas * 0 acres 0 % of site (excluding water area) c. Water Area 0 acres 0 % of site d. Commercial 0.39 acres 100 % of site Industrial 0 acres 0 % of site Public/Institutional 0 acres 0 % of site Public, Private and Canal rights-of-way 0 acres 0 % of site Other (specify) 0 acres 0 % of site Other (specify) 0 acres 0 %of site e. f. g. h. i. j. Total area of site 0.39 acres 100 % of site *including open space suitable for outdoor recreation, and having a minimum dimension of 50 ft. by 50 ft. 5. Surface Cover 6. Floor Area a. Residential b. Commercial/Office 6,851 c. IndustriallWarehouse d. Recreational e. Publicllnstitutional 1. Other (specify) courts. site i. a. Ground floor building 1 , 975 . S . F. acres area ("building footprint") 11 .6 % of site b. Water area 0 acres o % of site c. Other impervious areas, including paved area of public & private streets, paved area of parking lots & driveways (excluding landscaped areas), and sidewalks, patios, decks, and athletic 11 , 1 7 R S F _ acres he;. q % of d. S (0.30 acres) Total impervious area 1 3 ) 1 5:3, . F . acres % of site 77.6 e. Landscaped area 0 acres 0 % of site inside of parking lots (20 sq.ft. per interior parking space required - see Sec. 7.5-35(g) of Landscape Code). f. Other landscaped areas, 3 , 793 S. F . 22.4 % of site acres g. Other pervious areas, including golf course, natural areas, yards, and swales, but excluding water areas 0 acres 0 % of site h. Total pervious areas 3,775 S.F. acres 22.3 % of site Total area of site 3,793 S.F_ acres 22.4 % of site o sq. ft. sq. ft. o sq. ft. o sq. ft. o sq. ft. o sq. ft. g. Other (specify) o sq. ft. h. Total floor area 6,851 sq. ft. 7. Number of Residential DwellinQ Units a. Single-family detached sq. ft. b. Duplex 0 sq. ft. c. Multi-Family (3 + attached dwelling units) (1 ) Efficiency 0 dwelling units (2) 1 Bedroom 0 dwelling units (3) 2 Bedroom . 0 dwelling units (4) 3+ Bedroom 0 dwelling units d. Total multi-family 0 dwelling units e. Total number of dwelling units 0 8. Gross Density N / A dwelling units per acre 9. Maximum height of structures on site 30 ' - 0 " feet 27'-0" 2 stories top of parapet top of roof 10. Required off-street parkinQ a. Calculation of required # of off-street parking spaces. Off-street parking spaces provided on site plan 5,280 S.F. of 200 = 26 = 26 = = b. Calculation of required # of handicap parking spaces 2 Number of handicap spaces provided on site plan 2 = REPRESENTATIVE OF THE PROJECT MUST BE PRESENT AT ALL TECHNICAL REVIEW COMMITTEE, PLANNING AND DEVELOPMENT BOARD OR COMMUNITY REDEVELOPMENT AGENCY (CRA) AND CITY COMMISSION MEETINGS HELD TO REVIEW THIS PROJECT. 12/17/2663 .~_ _561-575-5266 GGG & ASSOCIATES PAGE 62 III. CERTIFICATION (I) (We) underWind that thl. application and all papers and plans submitted herewith bec;ome a part of the permanent records of the Planning and Zoning Division (I) (We) hereby certify that the above ttatementa and any st<<,tement. or .howings in Bny pepsrs or plane submitted herewith are true to the beat of (my) (our) knowledge and belief. This ~pbtion wiU not be accepted unten eigned 8CCOfding to the Instructions below. It. /. /hr//7 1- Signature of Own6r(s) or Trust... o( Authorized Principal if property is owned by . corpo~tion or other businen entity. j ~ { 1"7 J 0] O~te OR Signature of contract purchalllr (if applicant) rv. AUTHORIZATION OF AGENT Date Date Signature of Authorized Agent (I) (We) hereby designate the abov....igned person as (my) (our) authorized agent In regen! to this application. i- I (- I. I~t!t Signature ofOWner(e) or Tru . _or Authorized Principal If property is owned _by. corporation or other business entity. /2)17)03 Ollte OR Signatu~ of contract purchaser (if applicant) Date A REPRESENTATIVE MUST BE PRESENT AT ALL TECHNICAL REVIEW COMMmEE, PLANNING AND DEVELOPMENT BOARD OR COMMUNITY REDEVELOPMENT AGENCY (CRA) AND CITY COMMISSION MEETINGS HELD TO REVIEW THIS PROJECT. RIDER TO SITE PLAN APPLICATION The undersigned as applicant for Final Site Plan Approval does hereby acknowledge, represent and agree that all plans, specifications, drawings, engineering, and other data submitted with this application for review by the City of Boynton Beach shall be reviewed by the various boards, commissions, staff personnel and other parties designated, appointed or employed by the City of Boynton Beach, and any such party reviewing the same shall rely upon the accuracy thereof, and any change in any item submitted shall be deemed material and substantial. The undersigned hereby agrees that all plans, specifications, drawings, engineering and other data which may be approved by the City of Boynton Beach, or its boards, commissions, staff or designees shall be constructed in strict compliance with the form in which they are approved, and any change to the same shall be deemed material and shall place the applicant in violation of this application and all approvals and permits which may be granted. The applicant agrees to allow the City of Boynton Beach all rights and remedies as provided for by the applicable codes and ordinances of the City of Boynton Beach to bring any violation into compliance, and the applicant shall indemnify, reimburse and save the City of Boynton Beach harmless from any cost, expense, claim, liability or any action which may arise due to their enforcement of the same. I1M;(O~ED=ANDAGREEDTOthis 11 W~~.2023 Witness Applicant Witness City Codes Accessed Via Website www.bovnton-beach.org www.amlegal.com/bovnton beach f1 CITY OF BOYNTON BEACH, FLORIDA PLANNING & ZONING DIVISION SITE PLAN REVIEW APPLICATION FOR DEe I 7 200.') NEW SITE PLANS & MAJOR MODIFICATIONS TO EXISTING SITE PLAN Has applicant attended a pre-application meeting? Date This application must be filled out completely, accurately and submitted as an original to the Planning and Zoning Division. TWELVE COMPLETE, sequentially numbered, ASSEMBLED AND STAPLED sets of plans including a recent survey and appropriate fee shall be submitted with the application for the initial process of the Site Plan Review procedure. AN INCOMPLETE SUBMITTAL WILL NOT BE PROCESSED. Please print legibly (in ink) or type all information. I. GENERAL INFORMATION 1. Pr~ectName: Boynton Beach Cancer Center (aka Freeman Medical) 2. Property Owner's (or Trustee's) Name: Boynton Beach Real Estate, LLC Address: 1 Portage Landing S, North Palm Beach, FL 33408 (Zip Code) Phone: Fax: 3. Applicant's name (person or business entity in whose name this application is made): N/A Address: (Zip Code) Phone: Fax: If contract purchaser, please attach contract for sale and purchase. 4. Agent's Name (person, if any, representing applicant): George G _ Genti Ie, FASLA Gentile Holloway O'Mahoney & Associates, Inc. Address: 1907 Commerce Lane. Suite 101. Jupiter, FL 33458 (Zip Code) Phone: 561-575-9557 Fax: 561-575-5260 5. Correspondence to be mailed to agent only; if no agent, then to applicant unless a substitute is specified below:* mail to agent *This is the one address to which all agendas; letters and other materials will be mailed. 6. What is applicant's interest in the premises affected? (owner, buyer, lessee, builder, developer, contract purchaser, etc.) N/A 7. Street address of location of site: 2375 W. Woolbright Road 8. Property Control #(PCN) 08-43-45-32-04-134-0000 9. Legal description of site: see attachment 10. Intended use(s) of site: medical office 11. Architect: Everett Jenner 12. Landscape Architect: George G. Gent i 1 e 13. Site Planner: Everett Jenner 14. Engineer: GGB Enqineerinq. Gary Bloom 15. Surveyor: FRS and Associates 16. Traffic Engineer: Yvonne Ziel 17. Has a site plan been previously approved by the City Commission for this property? Yes. July 18. 2000 II. SITE PLAN The following information must be filled out below and must appear, where applicable, on all copies of the site plan. 1. Land Use Category shown in the Comprehensive Plan: Office Commercial 2. Zoning District: C-1 , Office & Professional District 3. Area of Site 0.39 acres 16,946 sq. ft. 4. Land Use -- Acreage Breakdown: a. Residential, including 0 acres n % of site surrounding lot area of grounds b. Recreation Areas * 0 acres 0 % of site (excluding water area) c. Water Area 0 acres n % of site d. Commercial 0.39 acres 1 00 % of site Industrial 0 acres 0 % of site Public/I nstitutional 0 acres 0 % of site Public, Private and Canal rights-of-way 0 acres 0 % of site Other (specify) 0 acres 0 % of site Other (specify) 0 acres 0 % of site e. f. g. h. i. j. Total area of site 0 . 39 acres 1 00 % of site *including open space suitable for outdoor recreation, and having a minimum dimension of 50 ft. by 50 ft. 5. Surface Cover courts. site 11 _ 8 % of site a. Ground floor building 1 . 998 S. F . acres area ("building footprint") b. Water area 0 acres o % of site c. Other impervious areas, including paved area of public & private streets, paved area of parking lots & driveways (excluding landscaped areas), and sidewalks, patios, decks, and athletic 1 1 , 1 78 S _ F acres h l:) q % of d. Total impervious area (0.30 acres) 1 3 , 1 7 6 S. F . acres % of site 77.7 e. Landscaped area 0 acres 0 % of site inside of parking lots (20 sq.ft. per interior parking space required - see Sec. 7.5-35(g) of Landscape Code). f. Other landscaped areas, 3, 775 S. F . acres 22.3 % of site g. Other pervious areas, including golf course, natural areas, yards, and swales, but excluding water areas 0 acres 0 % of site h. Total pervious areas 3,775 S. F. acres 22.3 % of site i. Total area of site 0.39 acres 100 % of site 6. Floor Area a. Residential 0 sq. ft. b. Commercial/Office 6,874 sq. ft. c. IndustrialIWarehouse 0 sq. ft. d. Recreational 0 sq. ft. e. Public/lnstitutional 0 sq. ft. f. Other (specify) 0 sq. ft. g. h. Other (specify) o sq. ft. Total floor area 6,874 sq. ft. 7. Number of Residential Dwellinq Units a. Single-family detached sq. ft. b. Duplex 0 sq. ft. c. Multi-Family (3 + attached dwelling units) (1 ) Efficiency 0 dwelling units (2) 1 Bedroom 0 dwelling units (3) 2 Bedroom 0 dwelling units (4) 3+ Bedroom 0 dwelling units d. Total multi-family 0 dwelling units e. Total number of dwelling units 0 8. Gross Density N / A dwelling units per acre 9. Maximum height of structures on site 30' - 0 " feet 27'-0" 2 stories top of parapet top of roof 10. Required off-street parkinq a. Calculation of required # of off-street parking spaces. Off-street parking spaces provided on site plan 5,186 S.F. T 200 = 26 = 26 = = b. Calculation of required # of handicap parking spaces 2 Number of handicap spaces provided on site plan 2 = REPRESENTATIVE OF THE PROJECT MUST BE PRESENT AT ALL TECHNICAL REVIEW COMMITTEE, PLANNING AND DEVELOPMENT BOARD OR COMMUNITY REDEVELOPMENT AGENCY (CRA) AND CITY COMMISSION MEETINGS HELD TO REVIEW THIS PROJECT. 12/17/2003 09: 2~_.._551-575-5250 GGG & ASSOCIATES PAGE 02 III. CERTIFICATION (I) (We) understand that this application and all papers end plans submitted herewith b~come a part of the permanent records of the Planning and Zoning Division (\) (We) hereby c~rtify that the above statements and any statements or showings in any papers or plans submitted herewith are true to the best of (my) (our) knowledge and belief. This applictltion will not be accepted unless signed according to the Instructions below. i I ( /. ILrfl1 \' Signature of Owner(s) or Trustee, o( Authorized Principal if property is owned by a corporation or other business entity. j~{17/0] Date OR Date Signature of contract purchaser (if applicant) IV. 8J,LTI:iORIZATION OF AGENT Signature of Authorized Agent Date (I) (We) hereby designate the above-signed person 8S (my) (our) authorized agent In reg8lrd to this application. i. I ( I l~ff7 Signature of OWner(s) or Trustee{ _or Authorized Principal If property is owned _by. corporation or other business entlty. i2)17)o3 D.te OR Signature of contract purchaser (if applicant) Date A REPRESENTATIVE MUST BE PRESENT AT ALL TECHNICAL REVIEW COMMITTEE, PLANNING AND DEVELOPMENT BOARD OR COMMUNITY REDEVELOPMENT AGENCY (CRA) AND CITY COMMISSION MEETINGS HELD TO REVIEW THIS PROJECT. RIDER TO SITE PLAN APPLICATION The undersigned as applicant for Final Site Plan Approval does hereby acknowledge, represent and agree that all plans, specifications, drawings, engineering, and other data submitted with this application for review by the City of Boynton Beach shall be reviewed by the various boards, commissions, staff personnel and other parties designated, appointed or employed by the City of Boynton Beach, and any such party reviewing the same shall rely upon the accuracy thereof, and any change in any item submitted shall be deemed material and substantial. The undersigned hereby agrees that all plans, specifications, drawings, engineering and other data which may be approved by the City of Boynton Beach, or its boards, commissions, staff or designees shall be constructed in strict compliance with the form in which they are approved, and any change to the same shall be deemed material and shall place the applicant in violation of this application and all approvals and permits which may be granted. The applicant agrees to allow the City of Boynton Beach all rights and remedies as provided for by the applicable codes and ordinances of the City of Boynton Beach to bring any violation into compliance, and the applicant shall indemnify, reimburse and save the City of Boynton Beach harmless from any cost, expense, claim, liability or any action which may arise due to their enforcement of the same. ;;LM20~LED=ANDAGREED TO this 11 ~~.et-' 2023 Witness Applicant q Witness GENTILE HOLLOWAY O'MAHONEY George G. Gentile. FASLA M. Troy Holloway. ASLA Emily O'Mahpney. ASLA & ~SSOCi;TES I:.JC Landscape Architects Planners and Environmental Consultants' LC-OOOOl77 December 17, 2003 ,,' Ms. Lusia Galav, AICP City of Boynton Beach Development Department Planning and Zoning Division 100 E. Boynton Beach Boulevard Boynton Beach, Florida 33425-0310 Re: Boynton Beach Cancer Center (f.k.a. Woolbright Medical Building (Freeman) Site Plan Approval Application Dear'Ms. Galav, Please find attached the Site Plan Approval Application for your review. This submittal is to re. ~rtify the previously approved site plan for a Medical Office located at 2375 West Woolbright Road. The 6,874 sq. ft. Medical Office is two stories with parking below the building. As you are aware, the project received site plan approval on November 8, 2001. A one year extension was requested and approved extending the approval to November 8, 2003. In 2003, requirements changed to locate an x-ray and associated spaces on the ground floor, reducing the amount ofparki~g and related square footage. The name of the project changed to Boynton Beach Cancer Center. The project received a minor modification approval on April 4, 2003. Following the minor modification approval, working drawings were prepared and submitted for building permits. Unfortuvately, building permits were not issue~ prior to expiration of the site plan approval on November 8, 2003. Prior to submittal for building permit, the zoning code changed modifying the parking stall dimensions. Due to the restricted size of the site and the design of the building, the increase in stall size would require a complete redesign ofthe site and building. We submitted a request for an Administrative Waiver to the City Engineer. On December 10, 2003; the City Engineer approved this request. (See attachment) . The project also received minor comments while being reviewed for building permits. The attached submittal addresses these comments and we have included a response letter. (See attachment) Please,feel free to contact our office with any questions or concerns regarding the project. Sincerely yours, .J!L~fl~ Landscape Architect Gentile Holloway O'Mahoney & Associates, Inc. .. Attachment 1807 Commerce Lane. Suite 101 JUritpr, Horiaa 3='1458 Clh 1 575 U557 561 ,:~75-5~:viO f-AX \,wn.;,la ndscape -architects. com The City of Boynton Beach P.o. Box 310 Boynton Beach, Florida 33425-0310 PUBLIC WORKS DEPARTMENT FAX: (561) 742-6285 www.boynton-beach.org OFFICE OF THE CITY ENGINEER December 10, 2003 Everett H. Jenner, AlA Architect, Inc. 2647 NW 41st St. Boca Raton, FL 33434 RE: Request for Administrative Waiver Parking Stall Dimensions Boynton Beach Cancer Center Dear Mr. Jenner: We are in receipt of your request for an Administrative Waiver for parking stall dimensions for your proposed structure. Based on the justification provided in the attached letter your request is approved. If you have questions or need additional information, please feel free to contact me at (561) 742-6488 or Laurinda Logan, P.E., Senior Engineer, at (561) 742-6482. Sincerely, , ., \ 1;/. 1" './;>/' . \ ~' DaVi~~~~2:J:~'M City Engineer / \ \ , \ I \l HDK:LUck ~ Xc: Jeffrey R. Livergood, P.E., Director, Public Works (via e-mail) Michael W. Rumpf, Director, Planning & Zoning Ed Breese, Principal Planner, Planning & Zoning File S:\Engineering\Kribs\Boynton Beach Cancer Center, Req. for Waiver (Parking Stalls).doc America s Gateway to the Gulfstream ipiJ~ ;~;'~e~t~;eJenn:~~~~~, Ar~~~:~~~~~~~ Licenses: FL AA-C001794 FL AR-0007573 NY 007159 NCARS Certificate 3963 December 12, 2003 Boynton Beach Cancer Center Response to Comments: Lusia Galav April 4, 2003 letter of approval for minor modifications to the approved site plan. Response to Comments: 1. 12 foot utility area boundaries were corrected on the Civil Sheet 5. 2. Silver Buttonwood trees were changed to 12 feet height at planting. 3. Redtip Cocoplum hedge has been changed to 30 inches height at planting. 4. Comment is acknowledged. Karen Main 10/27/03 Plan Review. Response to Comments: 1. The front setback at the stairway is 40 feet. Dimension has been added to the Site Plan. The setback to the second floor of the building is 50 feet. The front setbacks were reduced as a result of the added ground floor X-Ray room, and approved. Please note the West side yard setback increased with the reduction in overall square footage from 13 feet to 17 feet, and has been corrected in this submittal. 2. The overall building height of30 feet (top of parapet) was approved by the commission. The tabular data has been revised accordingly. 3. Color chips are included with this submittal. These are the same colors approved by the commission. 4. Irrigation plans will be provided with the permit application. 5. Cross section drawings are included with this submittal. 6. Note to screen equipment has been added. 7. Cocoplum hedge height is now shown to be 30" at planting. 8. Understood. Previous site plan submittals included signage and have been left on as a general guide to locations for signage to be submitted for approval at a later date. 9. The plans are scheduled at this time for a full review. Page 1 2647 N.W. 41st Street Boca Raton, Florida 33434 (561) 241-3482 December 12, 2003 Boynton Beach Cancer Center Response to Comments continued Kevin Hallahan October 28, 2003 Plan Review. Response to Comments: 1. There are no existing trees on the site. Note has been added to Sheet L-1. 2. Note and specifications have included requirement for all plants to be Florida #1. 3" caliper requirement has been added. 3. Ficus hedge is eliminated, replaced with Cocoplum hedge. 4. Height of trees is shown on the sections on new Sheet L-2. 5. Liriope has been added. 6. Note to seed and mulch canal RO.W. has been added. 7. Note to screen utility structures has been added. 8. Irrigation note has been added. Ken Hall November 14, 2003 Plan Review. Response to Comments: 1. Please refer to attached copy of December 8, 2003 letter from this office to the City Engineer, and response letter approving an Administrative Waiver. 2. The 20 feet referenced is an easement. Please see the attached copy of the joint use agreement. The property is owned by the Cancer Center owner. \ . LAW OFFICE STEVEN T. UTRECHT. RA. 2295 CORPORATE BLVD., SUITE 211 BOCA RATON. FLORIDA 33431 (5611 995-1975 FAX (5611 995-1938 December 5, 2003 Mr. Everett H. Jenner, A.I.A Architecture Planning Interior Design 2647 NW 41 sl Street Boca Raton, Florida 33434 Re: Lake Worth Drainage District Easement Dear Mr. Jenner: Enclosed please find a copy of the Lake Worth Drainage District Easement per your request. If you have any questions, please feel free to contact our office. ( Sincerely, . ""\/. . .' /' 1 }//;'/ l l~~t < /,-;;:'.-'j 0> "';":.., , /... Teresa McCprmick, Legal Assistant STU/tzme Enel. Date: _4./U/ZOO;i T1me: J.U:L"a 1'''' Paso: 00 '1' . '" . o .vv."""""'.,........... lNAGI01 l rt-o~-~~11?-2 Gt/14/2003 lO;17:17am ..,. 1 01 ~ .. u ... .-..... fIQ'UIN TO: . lAKE WOITH DRAINACE DI51'RtCT ~& 130lh MiDuryTQII , Cr Delray..... n. 33414 "!PAlEO BY: ~A- PElKY PIIUlY & KIlN. ".A. SO SE faunh Awnuc DeIrar 8ac:h. FI. >>483 eu,~ 1.1.... .lIllIn.,,, .. 13115.._ PAlA Dun a..tJ, rl...ilf. JOINT USE WIMEN1' M'ilBMINT nus AGIUMINT etMnd iM) Chit...J!J....af ~ 2002. hy _ helwelft tAKE WOITH DMtNAGf OI$TllCf. , ~ T.... 0Isai<l 1ft .... Stale 01 F1~ .... flllillns iddfts is '., MiliQry TrJI1. DefNJ 8NdL ffotidi "'*. haroInaM ..ranIId It) ~ "DISTRICT# . iI'Id WOOlnlGMT COlI. Of IIOYNJON 8IAOt. .. ~iaft __q under the IawJ of me Sla ." ~ whose INiIin& .... It .m SOUIh MiIiIiry Tfilil. !kine D2. "'011 ~ ffaridil JJ.U6. "'Nil'" ........10 IS "lANDOWNEr. WHlIIAS. LANOOWNat . _ awttar ct ftftalIt Plapetly IaaI8d in ,.. 8M'h I Caunly, flad$.. .....10... OtSTRlCT'$laral en No. _: and WHEIIA5. DtSlI1Cr awns. CDfMtQIs ~nd IIIiinIiIinJ Ihal canal iderIIW oIS laril CINI No. 26. which is uplift.... wilhin thai ......r ~ CIMIId br lANDOwNFII:..nd WHI"\S.. the-~ ~re 10 cnIPr iII1o. Joint U. ERb..ad4 ApBellIeel...., on aM iIpan .... ptGlill<<Y ~ ...... to .w.m... "-") . mare PMialIIriy dllfiCribed Oft ExhIbiI · A- ibched.... .... ..... a pM hettol NOW. lItfIIlOIL far Ten ~ 1110.CIQJ MId aIIW ... ...d ~ ~ rea!Md br -..h P8"Y Itam the.... iris""" ..... foItawt: t. The..,. ~i _!rue.... C"Gm!CI iWld fftCGlpOtillC.'d .., br rer...nce. 2. lANOOWNtI ,.aw.. ~ with ..,. ~ ttI IItb 10'", U. ~.... ~ ..... ... cIeIMr to'" 0ISTaIC:1' .,. achIlIve ~. CMft', CIIt - UDOn "* p"peIIy .. IftGIW patIlaaIatIy ~ .~ in Exhibit ""-, ~ 10 Ihe 181T1'15 .. CCftdhiGnS af ....Iub;cct Joint Ute: flMJNtJJ AanNmfnL """',1)' Oat.~:. 'Il"ZOO~ 'l'"1me: .I.U;&.-a -.... .v. Page: 00 i14 Q ..,..,....,..,,-.-...... EMAO&Ol : ~L-O~-~J\1'-2 04/14/2003 10:11:l14. lIaCJe 2 Cof S _ ,.. ... a411 J. l>>lDOWNEl shalt fMah --.. pu.su.anl1O ~ pQm ~_ by bereft H. Jennar. AlA. far Jab Net. 20006.. W~. ~ luihtiftl, MId ..1fIMWd by DISTRICT ~ 1-'. 2002. ... LANDOWNi1t,...,.... ,.pansItlIe far' ....... IN IlKCIr.,-......",.. eM"'_ ty!mr...lIII..,latlhe~ rJtheprajcrr. I S. LMIDCJWNa shaI. n.bnnifr MIl haId haPnIess die DISlRICT fer <11I'I dnd ai, dimaae ". may be CiIINCf bw ... DISTRICT ID ... ....... while ...0-' its 1I!IpOnI1I1t11ift iInd CIbI~ vi,., .....'II>.~ d1ls .......... 6. LANDOWNeR ~ 10 1~ Md tlOId .., 0I5TIICT huIwIIe>> d .nI ,." iIII'/ .. .n IL1bPIty whtCl1 1m! DI5TRICT may or aMd ... 4$ . h:Nt 01 I.ANIXJWNER'S Ide 01... Joint Uae ~ """ IndwdinJ hue nor: IImlled _ ...... ar IflIury 10 Ihe public OIID 1ha ~1 Sb'uaUnI iUeIf. 7. \ANOOWNEa lIhaIJ .... ... DI5mICT apinst lIftY and ~ .... br . senwaI'lIbibIy PDficy Nmi"l 1M lAKE WOkTH DRAINAGE 0I5TIICT ill an adrIIdaNI ..... ....... In .. aMGuftI of ONE MIll.ION DClllAItS Sl.oaD.aao... .... N tum inIuMnce policy &hd '.Irapl in .... fotR ifld .crea cIurint _ ..... of ,.. ~ and the e1pn115 01 AIM IhIIJ be bamllIt' LANOOWf& _Irs IUCtBSIII5 iIIIdfor iII5W's. PloD( of sIICtt co..CI'tJIC ... bo cWhenId Ia .... OISTRCT within BO) diys prior . Ihe iMWl ~ ~ IX Ihe "iCy: tn Ihv 1WIft, L,\NQOWNS ..... said ~ pAlic.y 10 .... lbit Joiftr us.: Easement ~ .. be IetmNted. and ~ IIIiII be . fie of . t THE HtJNDIfO DOLLAaS CSJGO.OOlID hale saId,....ll...~ e. DISTRICT.aII have lite riIht .. iIPIIOft in wrItIna ... ~ .. ~ of It1IIl'WIerfl "'" fiIhts.,. ClOftdilicns ({,lrI....1n tNsJafnt Use e-fIllelIlApef~.mr. whlch ~.. thIIl_.. tlNllllrnbIv willi...... 9. NoICof in ~;UI1Ctian with !his ~.~1I ..., tMa .. _ ...... 10 rhe 1riaI'1IWInB..w __.. Uf'lte. noIiIed 10ft ~ lWDO; Lalla Walth 0raiNp DiIricl 13"1 A.tiIiriIry TrMl ~ray..... A. U4I4 Capv 10: ,..... A. ,." EIq. 10 5.E. Faufth Melt_ DrJqj.... fL 33413 """"'.0, z ua't.C::: Q 1 1.'tl .:;uu~ .& ",-'IIIi" .Lv....yo Paso: 00 J14 I~aOl I rL-O)-3)117-2 O(/~4/200~ lO;17:174m t LANDOWNER: 1'.9"'" , en: 5 ... 1" lIME '_I WGoIbriJtI Cop. cI...._ 8eKh 9775 SouIhMliwv TraI. SUite Dl 8oyn1Oft Beach. FL J3436 " 1M WITNESS WHEIfGF. tho pallia haw heIeunID C!lf<<tlled ... Jaint U. -....... ~ .....,... \lMl"1l1SI ... wriIICln. W1lNfSSfS: ".:, ;.' f"... '." . " ' . . {', ,. ,. :~~". .:.;. If .. . .~.;:. " . '. s. - ~ . . .. I5ealI 111........... W1fIIIICt ......" WIutca ."w-..... ,...,.... at WiIIIIm 0...,...... -..... .. p . .. i _: ;--~:-;;;;-:~:I:.~' Ats...tt .. f (1- ." . ~ -- .. ... '.\ ;.:.~.: J.. ........01 .-:.....,~. ..l ". \." .":.:.~:;..-. . ~ WOOLIRIGHT r.OU. OF IOYNTOH 8IAOf Iv. ee.",tI~ ,-..,. ~~~~ ,. II ~~ .~JYJ6 J __.__......,--.1....... I -i ~ I ! , , ---!---L ! , -L-L I ! ---'- I ~ -L.L I i ---.L.-.-!- , ! --L-L &, I ; I ' ---r-+- ! ! ----- i i --r-I I , IT I I iT ----,---.,.- : j tt J-L ; ! +t ---r-r- ! I ---l--+- : I I I -r----r- D- I ; IT iT ~ I I -l---.;- I ! j ~ Engineering, Inc. 3109 Stirling Road, Suite 201 Fort Lauderdale, Florida 33312 Ph: (954) 986-9899 . Fax (954) 986-6655 email: gbloom4329aol.com June 26, 2000 City of Boynton Beach 100 E. Boynton Beach Boulevard P.O. Box 310 Boynton Beach., Florida 33425-0310 Subject: Woolbright Medical Building GGB Engineering, Inc Project No. 000430 Gentlemen: This shall Certify that the proposed floor elevation of 15.00 NGVD set for subject project is above the highest 100 year base flood elevation applicable to the building site as determined by the South Florida Water Management District's surface water management construction development regulations (Section 3107.1.2, Chapter 31 of the Boynton Beach amendments to the 1977 edition of the Standard Building Code). The Drainage design utilized for this project will conform with all roles, regulations, codes, etc. including, but not limited to Chapter 6, Article 4, Section 5 of the Land Development Regulations( Sec. 7 F.2). If you have any questions with respect to this certification, please feel free to contact this office. CIVIL AND FORENSIC ENGINEERS. LAND PLANNERS. CONSTRUCTION MANAGERS ;-;....~ . . i I I ! I ! I I m,il: ! I I I i i ! i : I I , I I i I i I , I -Ll I I ----r--r ----LL I I II ! 1 ----- , , i i iT I , 1 IT ---+----+- ; , , I i , --'--t- . I IT --r--t- I I -+---+- i I --+-+ -L-L- I i ......l..-.L ! i 11 TI ----+- , I --.- , i , { iT Engineering, Inc. 3109 Stirling Road, Suite 201 Fort Lauderdale, Florida 33312 Ph: (954) 986-9899 . Fax (954) 986-6655 email: gbloom4329aol.com Woolbright Medical Drainage Calculations June 21, 2000 Site Area = 16,949 Sq. Ft = 0.389 Acres Impervious Area = 12,218 Sq. Ft. = 0.28 Pervious Area = 4,191 Sq. Ft = 0.10 Building Area ground = 540 Sq. Ft = 0.009 Drainage Criteria = Storage and Exfiltrate 2.5 inches per Hour Seep32e Trench Desi2D L = CAR K(2HxDu-Du + 2HxDs) + 1.39 x 10(-4) x WDu Where: A= drainage area of 0.389 Acres C = 0.28 x 0.90+ 0.10x 0.5010.389 = 0.776 R = 2.50 inches W= Trench width = 4 feet K = Hydraulic Conductivity = 3 x 10(-4 )CFSIFf2 per Pt of head H= Depth to water table = 5.0 feet Du= Non Saturated Trench Depth = 3.0 feet Ds = Saturated Trench Depth = 1. 0 foot Solving for L = 0.7547 .01230 L = 61.35 Use Safety Factor of 2 L = 61.35 x 2= 122.71 LF Exfiltration Trench Required L = 124 LF Provided OK CIVIL AND FORENSIC ENGINEERS. LAND PLANNERS. CONSTRUCTION MANAGERS -v ~1:~ / QJ @NUTTING Ie ENGINEERS OF FLORIDA INC. ESTABLISHED 1967 Geotechnical & Construction Materials Hydrogeology & Monitoring Wells Engineering · Inspection · Testing www.nuttingengineers.com June 16,2000 Everett H. Jenner, Architect, Inc. 2647 NW 41st St. Boca Raton, Florida 33434 Subject: Report of Exfiltration Test Northwest Comer of Woolbright Road & SW 22ud Street Boynton Beach, Florida Dear Mr. Jenner: Nutting Engineers of Florida, Inc. has performed an exfiItration test for the proposed drainage improvements at the above referenced site. This report presents a brief description of the field procedures, and provides the results of the ex filtration test. One ex filtration test was performed at the site as requested by the client. 1bis test was conducted to a depth of six feet below existing grade in accordance with South Florida Water Management District (SFWMD) criteria for 'Usual Open-Hole' conditions. Prior to starting each test, a 6-inch diameter hole was augered to the test depth to detennine the depth to groundwater and to examine subgrade soils. After establishing the above parameters, the hole was stabilized by a full-length perforated PVC pipe in accordance with South Florida Water Management District specifications. Water was then pumped into the hole maintaining a constant water level at the ground surface. The stabilized flow rates were recorded in one minute intervals for a total of 10 minutes. 4 The exfiltration test revealed the hydraulic conductivity CK'-value) of the soil was 3.0 X 10- cubic feet per second per square foot per foot of head. Soil descriptions and flow rates for the test are shown on the attached exfiltration summary sheet. We note that the water table was at a depth of approximately six feet. 1 1310 NEPTUNE DRIVE · BOYNTON BEACH, FLORIDA 33426 Palm Beach (561) 736-4900. Broward (954) 941-8700. Miami-Dade (305) 858-0981. Fax (561) 737-9975. Fax (954) 938-8900 We appreciate the opportunity to provide these services for you. Should you have any questions, or if we can be of further assistance, please feel free to contact us. Respectfully Submitted: NUTTING ENGINEERS OF FLORIDA, INC. ~uJd-/~ ~/f&>IOo Richard Wohlfarth, P./. Florida Registration #50858 Senior Engineer Jenner perc/RCW @NUTTING ~ ENGINEERS OF FlORIDA. INC. ESTABLISHED 1967 2 Geotechnical & Construction Materials Hydrogeology & Monitoring Wells Engineering · Inspection · Testing ESTABLISHED 1967 www.nuttingengineers.com CLIENT: PROJECT: LOCATION: Evert H. Jenner AlA, Architect, Inc. Drainage Evaluation NW comer of Woolbright Rd. & SW 22nd Street Boynton Beach, FL Usual Type Open Hole Exfiltration Test ORDER NO: REPORT NO: DATE: 12313.1 1 6/08/00 TEST: SURFACE ELEVATION: Approx. 6" above road crown CASING DIAMETER: 6" TUBE DEPTH: 6' Water table from ground surface 6' ONE MINUTE INCREMENT PUMPING RATE IN GAL/MIN LOCATION: Approx. center of property I 2 3 4 5 6 7 8 9 10 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 MATERIAL DESCRIPTION: 0-2' Lt. brown quartz fine SAND 2'.3'6" Brown quartz fine SAND, little rock fragments 3'6"-6' Brown quartz fine SAND K = 3.0 X 10 -4 cfs/ft2 ft. head JENNER1.mc 1310 NEPTUNE DRIVE · BOYNTON BEACH, FLORIDA 33426 Palm Beach (561) 736-4900. Broward (954) 941.8700. Miami-Dade (305) 858-0981 · Fax (561) 737-9975. Fax (954) 938-8900 ~~ YVONNE ZIEL TRAFFIC CONSULTANTS, INC. 11440 86th St. North, West Palm Beach, Florida 33412 Telephone (561) 624-7262. Facsimile (561) 624-9578 January 29, 2004 , i. Mr. Michael W. Rumpf Planning and Zoning Department City of Boynton Beach 100 E. Boynton Beach Boulevard Boynton Beach, Florida 33425 r-to - J 2004 RE: Boynton Beach Cancer Center (tka Dr. Mark Freeman Medical Office) Trip Generation Dear Mr. Rumpf: This letter serves as the Traffic Generation Letter for the above-referenced project. The proposed facility is located on the northwest comer of Woolbright Road and SW 220d Street in the City of Boynton Beach. The proposed project involves the construction of a 5,282 square foot (SF) medical office. Please find enclosed Tables 1, 2, and 3 which provide the trip generation rates used and the trips generated by the proposed project. The proposed project results in 12 AM peak hour trips and 18 PM peak hour trips. Since the total peak hour traffic generation expected from the proposed project is less than 20 peak hour trips, a traffic study is not required. Sincerely, inda Riccardi, PE Project Manager ENCLOSURE Traffic Engineering and Planning ~ C"> C"> ~ ~ UJ ffi \0 \D C"> I- <t <t 'Z ~ ~ l- t- )< )< UJ UJ 'ZUJ en 0::. ~t c:t> r:tJ UJo::. \.0 \D ~ ~ ~UJ ~ o..UJ ZIQ ~'Z ~ UJ'Z I-w UJ I- o..w ~..) 0.. t:. ~ Q'l Q'l ~ UJ4:. ~ ~ ~ ~ c<i o..IQ 0..)-: ~I- CX?0::. 0 I- 0.. enUJ 0.. t ~ <Q'Z ~ 0 o..UJ I- IQ eO ~en 0.. t ~ l- i wUJ IQ o..~ ~o::. 0.. I- 0.. Z t:. C"> ("') 0 C"> ("') ~ 0 - I- ('I I;: I;: I-~ ~ ~ ~ ~ Q'l Q'l :t: ~ (/) 'Z ffi m 9:0::. 'i 0 ~ 'i o::.UJ 0 0 w 'i 00::. c:t> ~ ~ UJ(/) I- ~t o::.UJ .z. w ~'i 09: ('I ('I w(/) w'Z 0 0 0::.0::. ~ -r" oUJ o::.Z 4:.w ZIQ ~ o..w ~ UJ UJI- ~o::. C"> wO o..t C"> C"> 05- ~ I- ~ 0- ~ ~ C">~w <t z.~ 2IQ oz c--l UJ 0 ~~o m N<:c.o::. UJoZ 0.. t:. 0.. ~OUJ I- ..) 0 ~ ~ UJ - ~ ~:t:z ..)o~ -t <.!> ~:t:m 4:.)-: ~:t:o::. I- 0.. I-<a<.!> I-<a<:c. d;10::. ~(/) IQ ~ w~ ~ I-%~ UJo.. (/)w wUJ I- eOl <Q'Z I- eO~ zen eO't5 o..~ <Ii ZI- 0<Q o..UJ Zo.. 20::. ~ 0 'Zo.. 0- 'i t ~ 0::. b 'ZI- ~ Z b I-en ~ ~ IQ )-". C"> (5 ~~ Q'l Q'l eO 0 ~ eO ~ ~ I- ~ <g Z eO u.l I- ~ ~ r-o::. Z ~ c:t> c:t> ~o.. 0 ~ ~ ~ ~ Z I- ~ '0 ~ 0 ~ 0 I ~ <:c. (/) UJ ~ lffi ~ ('I <Q t- ~ 16 0.. UJO (j) 1;:0 ~ \.0 0 I- ~ u.. J> ~ 0 0> <Q 0> UJ ~ en u.l ~ I- ill 0.. 0.. 0.. ill ::> 0 ~ 0 I;: u: I- 0> u: ~ u.. ~ ~ if) u.. ~ W 0 ill 0- 0 t Q ~ u.l Ul (/) Z ~ (/) t ::> ;J. u.. r .(l. ::> 0 0 u.. ~ ql(::i 0 0 0::. 0 0 0 0 c: .' ~ ::> 3 UJ UJ t tG~ ~ (/) Z ..., . 0 ~ r d> ~ ..) ~ \ en ::> () t (">10 0 6 3 UJ IQ ~ I- Boynton Beach Cancer Center Calculations Summary; Openings in Exterior Walls Building Classification: Type IV, unprotected, unsprinklered FBC Table 600, exterior bearing walls 1 exterior non bearing walls: Distance from property line: (no walls are closer than 10 feet to a property line) over 10ft to 20 ft NC (20%) foot note c over 20 ft to 30 ft NC (40%) over 30 ft NC (NL) NC = Noncombustible NL = Not limited FEB 3 2004 foot note c: 705.1.1.2 exception for opening protectives in walls within 15 ft of a property line when walls are not required to be fire rated. South Elevation: Walls are over 30 ft from PL: Wall area: 1317.59 SF, Openings: 214.95 SF = 16.3% North Elevation: Wall area 20 ft from PL: 57.8 SF, Openings: none Wall area over 30 ft from PL: 920 SF, Openings: 80 SF = 8.7% West Elevation: Wall area 17 ft from PL: 1700 SF, Openings: 240 SF = 14.1 % East Elevation: Wall area over 10 ft to 20 ft: 2088 SF, Openings: 245.8 SF = 11.77 % Wall area over 20 ft to 30 ft: 1081 SF, Openings: 160 SF = 14.8%, allowable in this wall is 40% less 11.77% used in wall at 10.25 ft from PL = 28.23% , actual is 14.8%. OK Except for stairway walls, per table 600 as applicable, walls are required to be non- combustible, openings do not require protection. Stairways, per Table 705.1.2, less than 4 stories require 1 hr rated walls with 1 hr rated protected openings. Rated walls and doors are provided at the stairways. ~ YVONNE ZIEL TRAFFIC CONSULTANTS, INC. u{{(~ ovy 11440 86th St. North, West Palm Beach, Florida 33412 Telephone (561) 624-7262 . Facsimile (561) 624-9578 June 5, 2000 Mr. Michael W. Rumpf Planning and Zoning Department City of Boynton Beach 100 E. Boynton Beach Boulevard Boynton Beach, Florida 33425 RE: Dr. Mark Freeman Medical Office - Trip Generation Dear Mr. Rumpf: This letter serves as the Traffic Generation Letter for the above-referenced project. The proposed facility is located on the northwest corner of Woolbright Road and SW 22nd Street in the City of Boynton Beach. The proposed project involves the construction of a 6,000 square foot (SF) medical office. Please find enclosed Tables 1, 2, and 3 which provide the trip generation rates used and the trips generated by the proposed project. The proposed project results in 195 daily trips. Since the total average daily traffic generation expected from the proposed project is less than 200 trips, a traffic study is not required. Sincerely, YVONNE ZIEL TRAFFIC CONSULTANTS, INC. . /l(;/Jdifi- - Linda Riccardi, PC: cP-?cJO Project Manager ENCLOSURE Traffic Engineering and Planning --4 ~ r"" S \3 ~ 0 00 ?- 0 (fl ~ .. ~q' ?- c --4 ~ r"" 0 \3 ~ .Po- <- (fl ~ --.I C Z 0 m c 0 .' ::> ~ m 0 o . 0 --4 0 ?J o 0 11 ?- '0 0 0 ?- c "t)0 11 C tl:' (j) s; --4 0 Z ?- (j) m 2 ~ m Z 0 -0 m 0 11 V! ~ 11 ~ 11 --4 11 0 1.0 - ::\ 2 0 m -0-0 -0 m S ~ m~ V! ~ m (0 ?J(fl 1.0 a 0, 11 ~~ --4 0- (.1\ -4 (fl ?J 0--4 -0 (jl ~ ~ om -.I rn ):> .0 (j) 'C5 (fl S 0 -0 (fl 0 a . ~ -" ~ 0 ~ --4 Z 6 ~";P ~ -00 -" -" Z ?J--4 (0 (0 0 (.1\ (.1\ -I 0 m '-" ~ ?J ~b z J>. -4 0 rV rV ?J Q -" ro ~ ~ ?J 0 0 -.I (j) (.1\ (.1\ (fl--4 ~ Z -4~ ?- ~ ~ m ?J~ ~7' -" -o~ -47' ?J -011 m-o ~7' 5fJ ~-o Q?J ~):> ?J11 mro (j)11 _?J --4 --4 rom zrn-4 m(fl '?J -orn 2 0 (j)~ -" ?J<{> ~m (;)m-4 -I ~*6; OJ rn-l m~";P -0 ?- -I m-<J> ~~";P z):>OJ (;) ?J ~z." Y- ~ o'J"tp mzr"" m ::0 _~ro zr"" -I ?J~m z o -" _ -0 S~ ~ z\3 0 -4 m z ~ m ):> rn rV m ~ rt1ro'-" -" :10 ?J J>. ?Jo -4 -" ?--o v> zo (]\ (]\ 0- ~ ~";P a --4- rorn ZO rn-o -4Z ?Jo ?- a ~rn mr -" -" ?-~ z~ (j)o J>. J>. :o?- --4-1 a ~ ~~ 11 (j)0 -" a> 11 m -" ~~ 11 ~ 0 11 rV rV 11 rn 0 z 11 -0 '0 J: ~~ rn -4 0 rn(j) -" -" m m m -" -" ?J ro Y- o ::\ ::\ ::\ rV m v> 0 ~ '-" <5 '-" '-" Z -0 -0 :;o~ -4 m ~-o a ~ -\ rorn f:. --4 (j)~ -" -0 S OJ -I m-O 0 ?- ?J ~~ b ::0 m(fl -4-0 -4 0 ?J' ~ ~ v> ~ ~ ~ ~-o 01 ~ ?-~ (j) -" ::\ -0 rn1'- rn-o m ~rn 3 ~ z-l -I~ ~ ~~ rV -4Z rn-O rV ?-~ (j) (j) "1J(j) ro -" -" rnZ m fT\ ~-I ~ ~ -.I ,--4 -" -" v> (j)\ (j) -I (j) 0) ~ m -" -" ~ (]\\ (]\ -"\ Dcparun"nt of Engirleuing aJ1ci J>ublic \\'od.." f_O e.~:;. :: 1 :!:Q ,.~'''''~ P<.!~ Be-a(:r.. ~-!... :;.';lco; .', ~~~'J} o~.:; ";000 ., \"-.~':"'~"" ~"'~:t~ It:".J.-il f; , w Palm Bea.c!\ CQ\lnty ~l'(i of Count)' C(>r.unissio".,~ M.;;~e Rlr" L~e. O~',;r -.\r~e:t H ,,"ew~ll. VOLC ':n.!.irr.'ar. Kare!t r. Ma.t~ ~~'~.:j~~. Mary McC~: . .... ~"'_: ,r ~. ,J ~ ' -. ~6~;~~,'i-' - Toro/~~.~~ _. . Co'"'t)- Mministtuor Robel'f Wel!....na!'\ -....11 ~.J~ Dppor:t.rl'l!?, ..';I,,"--ri~~ knon ~. ~;,-;.... "",~: >:-~,~j~.< .:.~~:~.;. '. ;2:~t~~~~~ii::!'~lR:"~~'2f~~':~"' :.:f'-J~::t>::: :' .....:t>. .r ~ . ...... ..::,~';~-;~~i~j!~r' . -l'~'; :. , . . '"." ,June 23, 2000 (,,1: r\(ll~;iae: W r:;~;fTipf [,,~t:;(:!O; .:;f FI;-;:~r::;.] 'S Zon:ng C;;~~~dn~~1ent C; t)( \.It2i~p~nef1t C..:.,' 07 2cyn:c:': ~'.~;~'::~I ~(>: ::.::ist 8ojn\c:r. 6,:,5C:1 Ef~'d_, f.."',~'rl!~r~)r;-a::'"': ~~ 3~11~~.:J310 RE: Wooforici',t M(:dic:ll Otlice (F:<."':' "_ I TRt~r-F lC. PEF:H)RMANGEST AND,e.' 'C'.'"" :-,;=: j!t " _~'~;.;.; ~.,;: ?:~f' i~e Pai:~i Be3c', ,::~unty Traffic Dj'.Iisicn :;as :-~,,~Ne': :::e lra;:;~; ~:';:., ::;(~._-t --':0 or: ..:\.:rh~' 23. ::';VC~ ~" ~Le project .entit:ec, ~'- :t:I:_~:-~~./<.,t~~~~l Qff;~~ ~~.':'-.:~E ~ .r ,:'suan~ ~\,... !;-i~ l.d~fi\' r-....:r~~rn1artge Standard.::. ': ':".~lC,::: 4: -;. t'~e P31:'"1' ...,=..-:; C.~r. _<:~~ De'/E:lc;;rre;,! ~~:,),~.,. The project is surr;'~~:.~";; 2S :;i"c....? Location: Municipa/;ty: Existing Uses: Proposed Uses: New O~ily Trips: Build-()ut Y~ar: l f I I j I L I ! l~,u . I Iff~:.! have any question~re9arding this de:l'tmi~at;Gn. pleas€' cC.r1tact r.;,,? 2! 52~ ..:iC"30 O~FlCE Of THE COUNT-" ENGI"'EcH <) / //7 " //;V). Mas::Juc Atefi, M Sr. Engineer - Tr cc: T "';"~''; Z'ei I ,,",'i,::j)f\St1t3'O~$ Inc. File- ~n~'<;; - TPS - Mun - Traf.ic Study P.ev.-:\, r:\TRAfF;C\r..a\Adrr;lfI'Appro~'als..QOC6~ 0. :::cc " ;......I_.-.~..... , \ ~;.r.. 'ooi< ....c_ Oc:.' "'\. ," ........ {" .....;?~'~1jt"....t,,~~~;;,~:....,.-................~- "',;A" i. ~t . - h.~-~}'~;~~:2~-~~:::~.- __.:~;~l~fi:.!,t:~;.;.:::;~: _~:~~:..;_~~~~.f!!~~,~~~10'f 47 A~ G ~Ighl ;3000..... IllI9U ~ Gentile HoDoway O/Mahoney . AllDelatel, Inc. Landscap.. Archilecls P1a..........s and Envlronm.....la1 Coneullanle 1~/ZI1 eomm....c:e Lan.. Suil.. 1/Z11 Jupll..... Florida 334!:>8 !:>E:>1-~1~-':l!:>!:>1 !:>E:>1-!:>1!:>-!:>2E:>/ZI FAX 1IoIWW.landec4lpe-arcWtect...com We are sending you: [] Prints D Letter D Originals D Disk copy D Specifications D Color Rendering D Samples D other These are transmitted as checked below: D For approval D For your use D As requested D For review & comments D For bids due D other Letter of Transmittal Attention: Company: Ms. Lusia Galav, AICP City of Boynton Beach Planning and Zoning Division 100 E. Boynton Beach Boulevard Boynton Beach, Florida 33425-0310 17-Dec-03 Boynton Beach Cancer Center Date: Project: 03-1207 Wendy J. Mahr, ASLA Job No.: From: Phone: FAX: Copies Date Description: 12 Cover Letter with attachments 12 Site Plan review aoolication 12 Sealed Survey 12 Site Develooment Plan 12 Landscaoe Plan 12 Architectural Plan 12 DrainaQe olan 12 DrainaQe letter and calculations 12 Traffic statement 1 Colored Elevation and color chios 1 $750 submittal fee Remarks: cc: Jeff Moore Everett Jenner Signed . vr./Ju Wendy J. ~h' {A/ (~(1 I //J(.~ ! t- -,.( (C 11'- Time and Date of Meeting ___ _ Those atten~~:~~~i~ I f~~. / - / Applicant's Name: PRE-APPLICATION CONTACT QUESTIONS Cv~f !k<,//L<.c'y;~ Phone: ---:;/ L/ or J AI 'Af-t '7 )/:; I ,r- { -'-5 <- 1. HAVE YOU SPOKEN TO AJ."\Y STAFF MEMBER ABOUT THE PROJECT? Yes No (IF YES, HAVE THOSE STAFF MEMBERS BEEN SCHEDULED FOR THE PRE- APPLICATION MEETING? STAFF MEMBERS NAlvIE: 2. LOCATION 9F Pl}OPE.R, TY.(CROS~ ~TREETS(1N1ERSECTIONS) //--1;C-'!-~[Cl/-;f /1/1'/ ./.;1t4:/' I . / ~. 11' " '" .). \VHA T WOULD YOU LIKE TO DO? /' NEW PROJECT / BUILDING EXPAL~SION OR MODIFICATION. CHANGE IN PRIOR USE? IS THE STRUCTlTRE CURRENTL Y VACANT? VARIANCE TYPE: POOL OR SCREEN ENCLOSURE CO!vITvfERCIAL PROPERTY? RESIDENTIAL PROPERTY? INDUSTRIAL PROPERTY? DO YOU Kl'JO\V THE ZONING CODE DESIGNATION? ; 4. TIME AJ.'ID DATE PREFERRED 5. HO\V M_A...LW PEOPLE vVILL BE AT THE PRE-.A..PP MEETING? Note: Tell the persoll that someone from the Department will call them to confirm the meeting. .................................................................................. · Pre-application meetings should be scheduled for a minimum of one (1) hour time module, and should be scheduled no less than two (2) days prior to date/time of meeting. If urgency is sensed, discuss with Mike or Lusia. . Meetine-s may be scheduled: Monday afternoons Tuesday all day Wednesday all day Thursday mornings Note: Lusia is not available for Tuesday a.m. meetings, and Mike is not available on Mondays between 11 :30 a.m. and 2:30 p.m. S: \P I ann i ng\P lann inglPre-app licationcon tactquesti ons.doc - * Wi'v l-612lGd7 1v1P!:>/lftt., 6h t L--D<<7 .* i I I I I -=&~J I I I I I ReL'~ :~/~~ I ~t ~~ 6'; - ~- 1~&L-'7 I I := ~r.~~~~:r~~ (i)-~} ~ / .. I ~~~4~zt~~ ~~::: I - I I PRE-APPLICATION MEETING LOG IHEETING DATE: D 7 -- tl9I ---1/:3 APPLICATIONS: ZONING DISTRICT: PROJECT NAlYlE: . I . Wc>'t)1 h;2. I 6>ff r Mebc. ATTENDING STA.FF: ?7,;;' L{;, ATTENDING AS APPLICA~ -T: P'C:'./' PHONE: I FA.:X: I NAlVIE OF APPLICAL'fT/CONTACT: Wr [( -t.~~\€~ttT ,....1T~v: tl7 , ADDRESS: PRON"E: PROJECT ADDRESS: - ...,-, '-1 e'HvL-t-:1 I FA....X: I PROPOSED TYPE OF USE/OCCUPA.'iCY: I DATE SUBIVIITTAL RECEIVED: , DATE DEl'ilED: I COIYl1"YIENTS: I:\SHRD.~ TA\PI~nnjng'.SHAR.ED\WP\PROJEcrS\l'RE APPUC.~ TIO.'''S \IEETL';C LOGS\P,e-Appli.:~(ion c.[.:c:ing log.do.: PRE-APPLICATION MEETING SIGN IN SHEET PLEASE PR.IN"T IYIEETING DATE: \ - 2-9- C:j TIME: ATTEl'i"DING FOR APPLICA1~T: NOTICE: The purpose of this conference shall be for the staff and applicant to discuss oyerall community goals, objectiyes, policies and codes :1SS rel:1ted to the proposed deyelopment and to discuss site plan review procedures. Opinions express at the pre-application conference are not . binding for formal reyiew purposes. Additional staff comments may be forth coming based on actual I b 'tt d ~ . 01 ans su rru e or reVlew. City of Boynton Beach I Attending for Applicant I Attending Staff . I~' /\ tf /~ Pt?IC T CA"'vl-J x'Tt/' -/v}.A:L-/T IT-" 'ly;;)"o CY:!r~ C4 ~J~v/ I I I I I I I I I I I I I I I I I I I o J:'.5HRDA T A\PLA.'i~[:'iG\.sHAR.ED\ \VP\FOR.\lS\PRE-APPL :\IE ET[,;G-S [G~ C'i" SHEET.DOC we" ~BRIGHT MEDICAL BUILDING SITE CALCULATIONS COMP ARISON SUMMARY January 2. 5, 2003 Zoning District: C 1 Area of Site: 0.39 Acres 16,946 Sq. Ft. Land Use: Medical Offices Approved Site Plan Building Ground Floor Area Impervious Area Landscaped Area / Pervious Area Total Area of Site Floor Area: Medical Offices Floor Plates: 1 @ 6,000 Sq. Ft. 1 st Floor: Vertical Access & Utilities / Mech. Total Square Feet 576 11,225 5,145 % of Site 03.4 66.24 30.36 16,946 Sq. Ft. 100% 6,000 Sq. Ft. (NA) 1,270 Sq. Ft. 7,270 Sq. Ft. Allowable Lot Coverage: 40% Lot Coverage Building Footprint: 6,695 ~ 16,946 = 39.5% Maximum Height of Building: 27 Feet Req'd. Off- Street Parking: 6,000 Sq. Ft. -;- 200 = 30 Spaces Provided: 30 Spaces Building Setbacks: Minimum Req'd. Front Yard: 30 Feet Side Yards: 10 Feet Rear Yard: 20 Feet Provided 60 Feet (from Woolbright Rd) 10 Feet on East Side 13 Feet on West Side 20 Feet Proposed Modifications Square Feet 1,663 9,693 5,590 % of Site 09.8 57.2 33.0 16,946 S.F. 100% 2nd Floor 1 st Floor 4,150 S.F. 965 1,352 6,467 S.F. 5,917 ~ 16,946 = 34.9% 27 Feet 5,155 S.F. :- 200 - 26 Spaces 26 Spaces 41 Feet 10 Feet 16 Feet (10 Ft. at Stairs) 20 Feet Note: No dumpster enclosure is planned, as trash pickup is to be at curbside with a Cart Storage Room provided. Rooftop equipment shall be screened from view at a minimum distance of600 feet. The proposed floor elevation of the lowest floor 15.00 NGVD is above the highest 100 year base flood elevation applicable to the building site, as determined by South Florida Water Management District's surface water management construction development regulations. The FIRM flood zone designation is A-9. The base flood elevation is 13.00 NGVD. I '" I;) c.J ~-7- -.r- .01 i J ., ~N\1? ! I I ,I I I I ! I ~ I I --- I I I I I I ~ I I I ..._i/ ~ II (<<) ~ l 1 :@ _=_::t.~---- - ; I -.- ...~-~-t----. -4,- H= ' I-- I ", :, ---=F al, I ~ . I ~ , 4: -- -r,-----r- ; ~I ~ I~ "'l -..--L~ ,__ is . +- ,J I ~ J ~ '2 4- ""-.) , I 1--1 ..... {) uJ -:2 .:J \- ? o r j --,-- '1 I '~_-1____ IO~ I I I ;-1 ijl i/ ~ // -===--==~==-_~--.=-===-=-=-=~===--===::::==::.~=:=-===~._._---_.-----==~--::-:-~-__ ...._. _____i._.-./-~- I 1-...----- 1 1 --t~:~-=- - o ~ l I o ~ -_.,.~_.__.._--_.__._---_._--,----_.._._.~.._---------.--" ._---_."._.~--,.__..- ~ - \- ...lJ . uJ d: '" ~ ~ n ~ "Z ,.j ...J , ('l .u c:-J I I ~ I \!', i ,1 'II II. /1 >> I .- /" 10 I I ie) I - , I ~ ~ ~- - a:,....- ~,-<( "'j~ <;)'::l~ \1.1-,) '%3" - ~ ..J tL '- r-',~ , " d:-L'UT L j L..-,- J.-.. J X 0) " '% ~ -4 ~ ___I '. //~~. I 1 i I // I . .,,_~_~L~) 61 ____...______.__._...._..__._.____.... ___.u. ..____,.__..~~__.__._.__.____._______..__..__....__." --" -- ... ...) :r: " :x: :z 04 ..... ....._--~ o i ~, I ! . -__ --J. C"'I011 .LH ~}~g100(\\ & I ':l ' ,I 'Z I .I.._J o ~ t. o "" ..J .( \J .(' "'2 ..c J a... u.) ,...... !~ I : 30 .- :;L . 3() ,'[1,.1/)3 Time and Date of \keting _ U' J L. Those clttcndin'2 n1cctin2: ~J-~C:- J~a~ /~ / PRE-APPLICATION CONTACT QUESTIONS Applicant's Name: EIJ~/~H 1 evl n o(?/p U Phone: rt~ () ~ 4 I 31<62 1. HAVE YOU SPOKEN TO A."'''''{ STA.FF lvlEvIBER ABOUT THE PROJECT? Yes No (IF YES, HAVE THOSE SL\FF MEMBERS BEE)[ SCHEDULED FOR THE PRE- APPLICATION MEETING? STAFF MEMBERS NA1\;IE: 2. LOCATION OF PROPERTY (CROSS STREETS/I"JTERSECTIONS) LJ(Ja-UJr(fltf A~{l. ~ ( F(~~) .). \\ rIA T WOULD YOU LIKE TO DO? ~r:\V PROJECT ~- BTJ1LDING EXPAt"fSION OR MODIFICATION. CHAt"fGE IN PRIOR USE? IS THE STRUCTURE CURRENTLY V AC~"JT? VARIANCE TYPE: POOL OR SCREEN ENCLOSlTRE CON1J\IERCL~ PROPERTY? RESIDENTIAL PROPERTY? INDUSTRIAL PROPERTY? DO YOU KNO\V THE ZONI0JG CODE DESIGNATION? 4. TlNfE At"\TD DATE PREFERRED 5. HOW NL~~y PEOPLE \VILL BE AT THE PRE-.-\PP MEETING': Note: Tell the person that someonefrom the Department will call them to confirm the meering. ................................................................................., . Pre-application meetings should be schedukd for a minimum of one (I ') hour tiwe moduk, :md should be s;:hedc:!ed no less than t\vo (2) days prior to date/time of meering. If urgency is sensed. discuss \virh .\trike or Lusia. . Meetin!!s ma\' be scheduled: .'vlondayafternoons Tuesday all day Wednesday all day Thursday mornings Note: Lusia is not available for Tuesday a.rn. meerings. and Mike is not available on Mondays berween 11 :30 J.,m. J.nd 2:30 p,rn. s: \ P Ianni ng' P lann ing\Pre-appl icationcon tactquestions.doc 'U::$l/;r;,~ A} /bdtcil etd;J . l/ (7Y-<-eh4~) .A1t~d -b ~ t)IoAJ PRE-A,PPLICA.TION IYIEETING LOG i TlyrE: /. 'J<J f J.1 I i'rIEETING DATE: I ". h -? //(PjO.:5 I APPLICATIONS: ~ f'~/V I . I ZOI'ilNG DISTRICT: C.-I I PROJECT NA.IVlE ~. . t1/v DJ/; 11 . ~/tJd;c;{l- 1r il nt ~ i ATTENDIl iG STAEF: u.uCt- I ATTENDING AS APPLICA.c.'iT: I PHONE: (~I) c9.~I- 3L{~ L ! N.~y1E OF _~PLIC.~'iT/CONTACT: I ADDRESS: I PHO~'E: I : PROJECT ADDRESS: I I - UJ CLi.I./U.nd'~ &ij7..at ?1v1u!~ I F.-\--:\': : :A.J I FA...X: i i ! I PROPOSED TYPE OF USE/OCCUPA.;.~CY: ~ U ! DATE SUBIVllTTAL RECEIVED: I DATE DEl'i ED: I COIYl1vlENTS: ~ ~ flail /YIocL~ I cci::f1Uvu if :wn p(1tJG~Y13 .~ /LUoI;)'I ~rCta.,. .su J ()d..rvJ- Sif'~- "caJ1?Ld2- /1..,..(.<1 Cftd ~ in'bk~~~ _ C7 lUo~ abk.ftJ J~ V/~ ~flotkil PdJ...k:p-. /Zf12/'die{<;; if:- f I.l/()~"" lu2 cL u()12j~/' lilY!: ~ J:'5HRDA TA'J':~nning\5HA...F,EDi \VP\PROJECTS\P~ ,-p rue,- Tro.'S "IEETL'\C L OCS\Pce-.'-ppli,:::ion ,,[co::,,::; Lu'; ~ 'c PRE-APPLICATION MEETING SIGN IN SHEET PLEASE PRINT lYIEETINGDATE: I !llp/03 TIME: (: gbf.ll\ ATTEl'll)ING FOR APPLICA.l"{T: NOTICE: The purpose of this conference sh:Ill be for the st:Iff :Ind applic::mt to discuss overall community goals, objectives, policies and codes ass related to the proposed development and to discuss site pl:In review procedures. Opinions express :It the pre-applic:Ition conference are not binding for formal review purposes. Addition:I1 st:Iff comments m:IY be forth coming based on actual I b 'tt d for review p. :Ins su IID e City of Boynton Beach I Attending for Applicant I Attending Staff t;l1A.!0 )/dav I C' ~~ Cj/e.~ ~ ~I/ J1tl.-c ~~~ I I v I I I I I I I I I I I I ~ I I I i I I J;'.5HRDATA\PLA'ii'iI.'iG\.SHARED\\Y1'\FOR.\[5\PRE_APPL :\[EET0G-SfG:\ ['; SHEET.DOC \\.,dLBRIGHT MEDICAL BUILDING SITE CALCULATIONS COMPARISON SUMMARY January 15, 2003 Zoning District: C 1 Area of Site: 0.39 Acres 16,946 Sq. Ft. Land Use: Medical Offices Approved Site Plan Building Ground Floor Area Impervious Area Landscaped Area 1 Pervious Area Total Area of Site Floor Area: Medical Offices Floor Plates: 1 @ 6,000 Sq. Ft. 1 sl Floor: CT Scanner & X-Ray Vertical Access & Utilities 1 Mech. Total Proposed Modifications Square Feet 576 11,225 5,145 % of Site 03.4 66.24 30.36 Square Feet 2,785 8,644 5,517 16,946 Sq. Ft. 100% 16,946 S.F. 6,000 Sq. Ft. (NA) (NA) 1,270 Sq. Ft. 2nd Floor 1 sl Floor 7,270 Sq. Ft. Allowable Lot Coverage: 40% Lot Coverage Building Footprint: 6,695 -7- 16,946 = 39.5% Maximum Height of Building: % of Site 16.4 51.0 32.6 100% 7,607 S.F. 6,687 -;. 16,946 = 39.5% 27 Feet 27 Feet 1,1 v Ji S"-O jl-/0'3 S/rt)S~. --- I 2' ~ICM fy!;'~ Req'd. Off- Street Parking: 6,000 Sq. Ft. --;- 200 = 30 Spaces Provided: 30 Spaces 4,192 S.F. .;- 200:; 21 Spaces 21 Spaces Building Setbacks: Minimum Req' d. Front Yard: 30 Feet Side Yards: 10 Feet Rear Yard: 20 Feet Provided 60 Feet (from Woolbright Rd) 10 Feet on East Side 13 Feet on West Side 20 Feet 55 Feet 10 Feet 16 Feet (10 Ft. at Stairs) 20 Feet Note: No dumpster enclosure is planned, as trash pickup is to be at curbside with a Cart Storage Room provided. Roof top equipment shall be screened from view at a minimum distance of 600 feet. The proposed floor elevation of the lowest floor 15.00 NGVD is above the highest 100 year base flood elevation applicable to the building site, as determined by South Florida Water Management District's surface water management construction development regulations. The FIRM flood zone designation is A-9. The base flood elevation is 13.00 NGVD.