Loading...
CORRESPONDENCE 't~""C'> , . , i,.. . \ '(\1\ .. }.J: 0\ /' ;"\" - /r:~ /" ' "'0;0" The City of Boynton Beach DEVELOPMENT DEPARTMENT PLANNING AND ZONING DMSON 100 E. Boynton Beach Boulevard P.O. Box 310 Boynton Beach, Florida 33425-0310 TEL: 561-742-6260 FAX: 561-742-6259 www.boynton-beach.org February 20, 2004 Ms. Donna Jones Fagundes Permit Xpress Re: AMF Bowling MMSP 04-023 Dear Ms. Fagundes: In response to your request date-stamped February 13, 2004 for the administrative review and approval of the modifications proposed to the above-referenced approved site plan, depicting the following: · Re-painting of the Bowling Center (as depicted on the attached plan) ; Please be informed that the proposed changes on the revised plan date stamped 2/13/04 are ~ Uminor" as defined within the Land Development Regulations, Chapter 4 Site Plan Review. This project may not continue to be processed by the Building Division as a permit application, due to the following condition: 1. Per the Community Design Plan, buildings located on separate parcels or part of a present or future multi-building complex shall achieve visual unity of character and design concepts through the relationship of building style, texture, color, materials, form scale, proportion and location. The color and application of the color to the building is not in keeping with buildings in the immediate vicinity. Should you desire to continue this project as proposed, you must apply for a Major Site Plan Modification and a Community Design Plan Appeal. As part of the application, you will need detailed plans, application fees in the amount of $1,150, and an understanding that the process takes approximately ninety (90) days. Should you desire to amend your current application to reflect the above comments, please submit revised drawings. -. Page2 February 20, 2004 Please contact me at (561) 742-6260 if you have additional questions. Sincerely, Ed Breese, Principal Planner Cc: Karen Main, Plan Review Analyst OCT-31-2003 14:17 FROM: -CD-. .--------- TO:804 5598689 P. 002/022 Ci't): Codt:s Al:l:c:ssed Vin. Wcbsite . W\....w,OQvlltl)r'\-bcD.ch.or!:! \\W\\, ..!:~~ leG~I,ccl1l/bO)'T",rO[1_bcuch_n.lJs CITY OF BOYNTON BEACH, FLORIDA FEe, 3 'Jrvu PLANNING & ZONING DIVISION Lwq SITE PLAN REVIEW APPLICATION FOR NEW SITE PLANS & MAJOR MODIFICATIONS TO EXISTING SITE PLAN I'las applicant attended a pre.application meeting? ,Date This application must be filled out completely, accurately and submitted as an original to the Planning and Zoning Division. TWELVE COMPLETE, sequentially numbered, ASSEMBLED AND STAPLED sets of plans including a recent survey and appropriate fee shall be submitted with the application for the initial process of the Site Plan Review procedure. AN INCOMPLETE SUBMITTAL WILL NOT BE PROCESSED. Please print legibly (in ink) or type all information. I. GENERAL INFORMATION 1. ProjectName: 'PIrYlF fu'ln-tcn ~e.(,d\..h Property Owner's (or Trustee's) Name: '(:+10) r d.,",--, 9 2. e(',"'...TCf~ ~J:I\L' , Address: \ \C\o i.) < ~~ rtt-M n .& r-...Q.j.-.., 'b\ \I L ""13,Q,,\ n.~ n &a.llJt I t=" L (ZJ: Code) .:3~'-1~"" 5\.,\ -'/6.~- \500 Fax: 5\01-'\0 - "'.?'~S? Phone: 3. Applicant'llname (person or busin.l'iss entityjn whose name this application is made): I' ~,r\ ~"- f(!J,t\.-" ,r, .-, f1 c: '-'-1"'-'5 .; ~ I ..1..--=......... <- c.f b)().,,),ylt .3"1"" ['" ,3,(\, I, L (,,----c '- Address: I \'j l' l I~C' , ) ,J Ill, ol . rL ~ ~~ H- Phone: ,~/-I ) \.(" I -J 3'-( I ~ L'iL\ Fax: ~-Ir r -'7\'1- If contracl purchaser, please attach contract for sale and purchase. 4. Agent's Name (person, if any, representing applicant): Address: PERMIT XPRESS Complete Permitting Service Phone: 5. Correspondence to be mailed 10 agent only; if nc is specified below:" (954) Donna Jones Fagundes Tel: 941-5605 Owner/Permit Expediter Cell 536.3959 Fax: 941.7507 'This is the one address to which all agendas; lettel 6. What is applicant's interest in the premises affected? (owner, buyer, lessee, builder, developer, contract purchaser, etc.) < 'u l.,_ (\ (J I~ 7. Street address of location of site: , \ q(J W. ~ 0-*on ~ (\ (\ h ~\. vd _ ~\\.\bY\ ~6-..ch, ~L.. 3~'l~ 10/31/2003 FRI 15:21 [TX/RX NO 7234] 141002 OCT-31-200314:17 FROM: TO:804 5598689 P. 003/022 8. Property Control #(PCN) (,' 5 ..{.) 'is :;2 '1 c. J.. II l C\.I.( I g. Legal do':scription of site: F 2 C L / IL' en l C' / ,),/(,,- J '! ,-I (I ! cd '-- /xyJ,-'" ! '(. ~ ' '. , (lQ , ,< _ 'v . b . ,0 t tL'L(,." ( ( ,- ( VQ -?-:Y n) 12 )" '\ i: f ;> )" . J 10. Intended users) of site: {;('LLI { ' '''j /-f" \'f~ Ce Ie" ; " ." <:", ,( / 11. Architect: 12, Landscape Architect: 13. Site Pianner: 14. Engineer: 15. Surveyor: 16. Traffic Engineer: 17, Has a site plan been previously approved by the City Commission for this property? II. SITE PLAN The following information must be filled out below and must appear, where applicable, on all copies of the site plan. 1. Land Use Category shown in the Comprehensive Pian: 2. Zoning District: c.. - ~ 3, Area of Site ~ . :\ q acres 4. Land Use .- Acreage Breakdown: i 0'--11 /0t sq. fl. a. Residential, including acres surrounding lot area of grounds b Recreation Areas' acres (excluding water area) c. Water Area acres d, Commercial acres e. Industriai acres f. Public/Institutional acres g. Public, Private and Canal rights-of.way acres 2 % of site % of site % of site % of site % of site % of site % of site 10/31/2003 FRI 15: 21 [TX/RX NO 7234] I4i 003 TO:804 5598689 P. 004/022 OCT-31-2003 14:17 FROM: h. Other (specify) acres % of site i. Other (specify) % of site acres j. Total area of site acres % of site "Including open space suitable for outdoor recreation, and having a minimum dimension of 50 fl. by 50 fl. 5. Surface Cover a. Ground floor building area ("building footprint") % of site acres b. Water area % of site acres c. Other impervious areas, including paved area of public & private streets, paved area of parking lots & driveways (excluding landscaped areas), and sidewalks, patios, decks. and athletic courts. acres % of site d. Total impervious area % of site acres e. Landscaped area acres % of site inside of parking lots (20 sq.fl. per interior parking space required - see Sec. 7.5-35(g) of Landscape Code). f. Other landscaped areas, % of site acres g. h. Other pervious areas, including golf course, natural areas, yards, and swales, but excluding water areas acres % of site Total pervious areas acres % of site i. Total area of site % of site acres 6. Floor Area a. Residential b. Commercial/Office c. IndustrialIWarehouse d. Recreational e. Public/lnstitutional f. Other (specify) g. Other (specify) h. Total floor area sq. ft. sq. ft. sq. ft. sq. ft. sq. fl. sq. ft. sq. fl. sq. ft. 7. Number of Residential Dwellinq Units Single-family detached sq. ft. a. b. Duplex sq. ft. 3 10/31/2003 FRI 15: 21 [TX/RX NO 7234] I4i 004 TO:804 5598689 P. 005/022 OCT-31-2003 14:18 FROM: c. (1 ) (2) (3) (4) d. Multi-Family (3+ attached dwelling units) Efficiency 1 Bedroom 2 Bedroom 3+ Bedroom dwelling units dwelling units dwelling units dwelling units Total muiti-family dwelling units 8. e. Total number of dwelling units Gross Density 9 dwelling units per acre Maximum height of structures on site feet stories 10. Required off-street csrkinq a. b. Calculation of required # of off-street parking spaces. Off-street parking spaces provided on site pian ~ ~ ~ Calculation of required # of handicap parking spaces Number of handicap spaces provided on site plan ~ REPRESENTATIVE OF THE PROJECT MUST BE PRESENT AT ALL TECHNICAL REVIEW COMMITTEE, PLANNING AND DEVELOPMENT BOARD OR COMMUNITY REDEVELOPMENT AGENCY (eRA) AND CITY COMMISSION MEETINGS HELD TO REVIEW THIS PROJECT. 4 10/31/2003 FRI 15:21 [TX/RX NO 7234] 141005 OCT-31-2003 14:18 _FRO~~_______ TO:804 5598689 P. 006/022 III. CERTIFICATION (I) (We) understand that this application and all papers and plans submitted herewith become a part of the permanent records of the Planning and Zoning Division (I) (We) hereby certify that the above statements and any statements or showings in any papers or plans submitted herewilR are true to the best of (my) (our) knowledge and belief. This application will not be accepted un~ a~~ ft'ttions be:o~. . J:n t / . f'-' ~-h~ mf ~;J,.)v{e41'J)J c . Signature of Owner(s) or Tfustee, of Date Authorized Principal if property is owned by a corporation or other business entity. OR Signature of contract purchaser (if applicant) Date IV. AUTHORIZATION OF AGENT Signature of Authorized Agent Date (I) tyJe) here~:'Sig.?Jte the above-signed person as (my) (our) authorized agent in regard to thi~~.~ . [J p .R~~ t3'fa:ft Ar7lt &7<0' (.e",,~'O~,.1),(. I J )'5 j'2 Signature of Owner(s) or Trustee~ Date or Authorized PrinCipal if property is owned ( / by a corporation or other business entity. OR Signature of contract purchaser (if applicant) Date A REPRESENTATIVE MUST BE PRESENT AT ALL TECHNICAL REVIEW COMMITIEE, PLANNING AND DEVELOPMENT BOARD OR COMMUNITY REDEVELOPMENT AGENCY (CRA) AND CITY COMMISSION MEETINGS HELD TO REVIEW THIS PROJECT. 5 10/31/2003 FRI 15:21 [TX/RX NO 7234] 19J006 OCT-31-2003 14:18 FROM: TO:804 5598689 P. 007/022 RIDER TO SITE PLAN APPLICATION The undersigned as applicant for Final Site Plan Approval does hereby acknowledge, represent and agree that all plans, specifications, drawings, engineering, and other data submitted with this application for review by the City of Boynton Beach shall be reviewed by the various boards, commissions, staff personnel and other parties designated, appointed or employed by the City of Boynton Beach, and any such party reviewing the same shall rely upon the accuracy thereof, and any change in any item submitted shall be deemed material and substantial. The undersigned hereby agrees that all pians, specifications, drawings, engineering and other data Which may be approved by the City of Boynton Beach, or its boards, commissions, staff or designees shall be constructed in strict compliance with the form in which they are approved, and any change to the same shall be deemed material and shall place the applicant in viola~on of this application and ali approvals and permits which may be granted. The applicant agrees to allow the City of Boynton Beach all rights and remedies as provided for by the applicable codes and ordinances of the City of Boynton Beach to bring any Violation into compliance, and the applicant shail indemnify, reimburse and save the City of Boynton Beach harmless from any cost, expense, claim, liability or any action which may arise due to their enforcement of the same. READ, ACKNOWLEDGED AND AGREED TO this day of ,20 . Witness Applicant Witness 6 10/31/2003 FRI 15:21 [TXlRX NO 7234] 141007 OCT-31-200314:18 FROM: TCl:804 5598689 p, 008/022 CONCURRENCY REQUIREMENTS NOTICE TO APPLICANTS FOR APPROVAL OF LAND DEVELOPMENT ORDERS OR PERMITS Pieas.e be advised that all applicatjo~s for ths following land developme~t orders aild permits which are submitted on or after June 1, 1990 will be Subject to the City's Concurrency Mana.Qement Ordinance, arrd cannot be approve~ .unless public facilities (potable water, sanitary sewer, drainage, solid waste, recreation., park, and road faCilities) wouid be available to serve the project, consistent with the levels of service which are adopted in the City's Comprehensive Plan: Building permit applications for the construction of improvements, which, in and by themselves, would create demand for public facilities. Applications for site plan approval. Applications for conditionai use approval. Applications for subdivision master plan approval. Applications for preliminary plat approval. Applications for final plat approval. Applications for rezoning to planned zoning districts. Applications for revisions to any of the applications listed above, which would increase the demand for any public facility. Any other application, which, in and by itself, would establish the density or intensity of use of land, or a maximum density or intensity of use of land. Applications for development orders and permfts submitted after Febnuary 1, 1990 and which generate more than 500 net vehicle trips per day, must comply with the Paim Beach County Traffic Performance Standards Ordinance, unless exempt from that ordinance. Please be advised, however, that the following applications will be exempt from the Concurrency Management Ordinance, pending final approval of this ordinance by the City Commission: Applications for the development of property which was platted on or after January 13, 1978 and either the final plat or the preliminary plat and Palm Beach County Health Department permit applications were submitted or approved prior to June 1, 1990, and the use of the property is consistent with the general use which was intended for the property at the time of piatting. Applications for the development of property, which was platted 'prior to January 13, 1978, the area of the platted lots does not exceed 2 acres. and the proposed use would not generate more than 500 net vehicle trips per day. Applications for building permit, if a site plan or conditional use application was submitted prior to June 1, 1990 and subsequently approved and the site plan or conditional use has not expired. Applications for the development of property within an approved Development of Regional Impact, and which are consistent with the approved DRI. Applications for approval of final plats, if the preliminary plat and application for Palm Beach county Health Department permits for utilities have been submitted prior to June 1, 1990. Applications for revisions to previously approved development orders or permits, which do not increase the demand for any public facility. 7 10/31/2003 FRI 15: 21 [TXlRX NO 7234] Ii!I 008 OCT-31-2003 14:19 FROM: TO:804 5598689 P. 009/022 Please. be advised that these exemption rules are tentative and will be subject to final approval by the City Commission. If you have any questions concerning the proposed Boynton Beach Concurrency Management Ordmance, please contact the Boynton Beach Planning &Zoning Division at (561) 742-6260. CHAPTER 4 SITE PLAN REVIEW Section 7. Submission Requirements. Each applicant shall submit to the Planning and Zoning Division the following plans and exhibits in the number of copies specified by the Planning and Zoning Division, together with a Site Plan Review application and a fee adopted by resolution by the City Commission. 12 ASSEMBLED COPIES REQUIRED A. ExistinQ site characteristics map: A sealed survey, not older than six months, showing all adjacent streets, alleys and driveways, and also illustrating: 1. Existing natural features, including but not limited to lakes, trees and other vegetation and soils and topography. 2, Existing buildings, building elevations, other structures, inciuding use, height, dimensions and setbacks. 3, Existing utility lines and ail easements, 4. Existing elevations (corner, street and finished floor) B. Site development Dlan: 1. A scaled drawing clearly illustrating proposed buildings and other structures, and any existing buildings and structures, whiCh are to be retained, including use, height, dimensions and setbacks. 2. Proposed off-street parking spaces, driveways and sidewalks, including location. dimensions and setbacks. traffic controi markings and signage. 3. Proposed fences and walls, including iocation, dimensions, setbacks, height and material. 4, Proposed location of lighting on site. 5. Proposed dumpster location. C. Landscape plan: 1. A separate scaled drawing (at the same scale as the site development plan) prepared as required by state law clearly illustrating proposed trees. shrubs, grass and 2, Proposed berms, watercourses and other topographic features, 3. A notation on method of irrigation. Architectural Dlan: 1. A scaled drawing clearly i1iustrating proposed building floor plan and elevations, including B 10/31/2003 FRl 15:21 [TX/RX NO 7234] ~009 OCT-31-200314:19 FROM: TO:804 5598689 P. 010/022 height, exterior dimensions, exterior cclor and materials. 2. A colored elevation drawing (not mounted) shoWing .all eievations of the building. (This submittal can. be waived tiy the Pi~nning arid It'Cling Dir''lctor when not applicable.) E. Tabular Summary Containinq: 1. Total gross project area by acreage and square footage and net buildable land area in acres and square feet. 2. Totai number of proposed residential units, including characteristics by number of bedrooms and bathrooms and gross square footage of each typical unit. 3. Proposed nonresidential floor type of use and total gross square footage. 4. Square footage and percentage distribution of the total project site, inciuding areas proposed for landscaped open space, vehicular use areas, other paved areas, and building coverage and total coverage. 5. Number and ratio of required and provided off-street parking spaces and number of loading spaces. 6. Water bodIes in acres and square feet. 7. Height of buildings. F. DrainaQe plan: 1. A separate scaled drawing (at the same scale as the site development plan) showing elevations, flow arrows, proposed drainage structures, proposed treatment facilities, etc. 2. An engineer's certification in writing that drainage will confomn with all rules, regulations, codes, etc. including, but not limited to, Chapter 6, Article IV, Section 5 of these Land Development Regulations. Revised 10/26/01 J:\$HRDATA\Planning\SHARED\W?\FORMS\APPL1CATlONS\NW8P\Revlsed Site Plan with Pre..application date.doc !I 10/31/2003 FRI 15: 21 [TXlRX NO 7234] ~ 010 , AMF BOYNTON BEACH LANES SCOPE OF WORK I PAINTlNCi SPECIFICATIONS PROJECT MANUAL DIVISION 9 EXTERIOR PAINTING reD I 3 ;:U04 9.01. GENERAL. A. Scope: This Section includes surface preparation and field painting of exposed exterior items and surfaces. Provide surface preparation, prime and finish painting of all exposed exterior items and surfaces throughout the project unless otherwise indicated B Exclusions: I. Finally-concealed items or surfaces, except those required to be color-coded for identification. 2. Glazed masonry block. ceramic and quarry tile, and exposed concrete floors (see Division 3 for scaler requirements), 3. Factory-finished items, surh\Ces, or materials, aluminum, brass, brunze, chromium plate, stainless steel. C Quality Assurance' I. Prepare surfaces and apply coating in strict accordance with the manufacturer's recommendations. ") Use only skilled painters for mixing and applying paint. Quality \vorkmanship is required. In the acceptanct; or rejt;ction of finish painting, no allowance will be made for the painters' lack of skill or inadt;quate lighting during painting operations. _'. All paint materials and equipment shall be compatible in use: finish coats shall he compatible with prime coats; prime coats shall be compatible with substrates; all tools shall be compatible with the coating to be applied. D. Materials - General: The same manufacturer shall produce each product in each paint system. I. Manufacturer quality standard is based upon: (a), Ben Moore (Paint Schedule Standard) .., Other acceptable manufacturers offering products are as follo\vs, ho\vever, do not reduce quality of paint from specification. Lo\vt;r grades will not be acceptahk: (a). Duron (b). Sherwin Williams E. Submittals: 1 Color sample for each color indicated 2. Manufacturer' product data for each product indicated. F. Project Conditions I Store materials not in use in tightly covnt;d containers in a well-ventilated area at a minimum ambient temperaturt.: of 45 dcg F (7 deg C). Maintain storage containers in a clean condition, free of foreign materials and residue. 2. Apply waterborne paints only \vhen temperatures of surfaces to be painted and surrounding air are bet\veen 50 and 90 deg F (10 and 32 deg C). 3, Apply solvent-thinned paints only \vhen temperatures of surfaces to be painted and surrounding air arc oct\veen 4S and 95 deg F (7 and 35 deg C). 4. Do not apply paint in snO\v, rain. fog, or mist; or when relative humidity exceeds 8S percent; or at temperatures h:ss than S deg F (3 deg C) above the de\v point or to damp or wet surfaces. 9.02. PART 2, PRODUCTS A. PAINT MATERIALS. GENERAL PROJECT 3352 SCHEIRMAN ASSOCIATES ARCHITECTS DIVISION 9 PAGElofl AMF BOYNTON BEACH LANES SCOPE OF WORK / PAINTING SPECIFICATIONS PROJECT MANUAL B Material Compatibility Provide block tillers, primers, and finish-coat materials that are compatible with one another and \vith the substrates indicated under conditions of s~rvict,; and application, as demonstrated by manufacturer based on testing and field cxpcrience. C. Material Quality: Provide manufacturer's best-quality paint material of the various coating types specified that are factory formulated and recommended by manufacturer for application indicated. Paint-material containers not displaying manufacturer's product identification \vill not be acceptable. D. PREPARATORY COATS 1. Concrete Unit Masonry Block Filler: High-performance latex block filler of finish coat manufacturer and recommended in writing by manufacturer for use \vith finish coat and on substrate indicated. Exterior Primer: Exterior alkyd or latex-based primer of finish coat manufacturer and recommended in \\Titing by manufacturer for use v,'ith finish coat and on substratL:- indicated. Ferrous-Metal and Aluminum Substrates: Rust-inhibitive metal primer Zinc-Coated Metal Substrates: Galvanized metal primer. Where manufacturer docs not recommend a separate primer formulation on substrate indicated, use paint specified for finish coat. o 3. 4. 5. E. Primers: E I IronClad Retard-X Rust Inhibitive Latex Primer ( 161) [2 fron Clad Galvanized Metal Latex Primer (155) E3 Moore's Latex Exterior Primer (102l E4 Moorcroft Vinyl LatL:-x Primer Scaler (171) E5 Eo Moorcroft Interior & Exterior Block Filler ( 173) [7 Regal Aqua Grip C(9) or Moore Latex Enamelllnderbody (345) E8 Finish Coats FI Moor(ilo Latex House & Trim (096) gloss F2 Moonvood Acrylic Semi-Transparent Stain (01)3) F3 Moorcroft Latex House & Trim Paint (170) .. Medium Gloss F4 Moorecraft Latex Semi-Gloss Enamel (276), or Moorecraft Latex Eggshell Enamel (279) F5 Moorecraft: Waterborne Acrylic Epoxy Enamel (279) F6 Regal Wall Stain (215), or Moorecraft Vinyl Latex Flat (275) F7 F8 F9 FlU Moorecraft Flat Latex House Paint ( 171 ) G. Exterior Paint System Schedule: Apply the following finishes to the surface indicated: Surface Primer Finish Coat(s) (Minimum) 1. Ferrous Metal E I FI 2 coats Ferrous Metal- Primed F I F I 3. Galvanized metal E2 Fl Wood- Stained F2 F2 W ood- Painted E3 F3 Masonry- Painted E6 F I 0 F. Soft Gloss, or Impervex Enamel (309) - High 2 2-coats 4, 5. 6. .2 coats 2 coats PROJECT 3352 SCHEIRMAN ASSOCIATES ARCHITECTS DIVISION 9 PAGE 2 of2 AMF BOYNTON BEACH LANES SCOPE OF WORK / PAINTING SPECIFlCA nONS PROJECT MANUAL 9.03. PART 3: EXECUTION A. APPLICATION 1 Comply \vith procedures specified in PDCA P4 for inspection and acceptance of surfaces to be painted. .., Coordination of \Alurk: Review other Sections in which primers are provided to ensure cumpatibility of the total system for various substrates. On request, furnish information on characteristics of finish materials to ensure use of compatible primers. .', Remove hardware and hardware accessories, plates, machined surfaces, lighting fixtures, and similar items already installed that are not to be painted. Ifrcmoval is impractical or impossible because of size or weight of the item, provide surface-applied protectiun before surface preparation and painting. 4. After completing painting op<:rations in each space or area, reinstall items removed using \vorkers skilled in the trades involved. 5. Surface Preparation: Clean and prepare surfaces to be painted according to manufacturer's written instructions for each particular substrate condition and as specifkd. Pressure wash, treat for mold. (a). Provide barrier coats over incompatible primers or remove and reprime. (b). Cementitious Materials: I. Remove efflorescenct;;, chalk, dust, dirt. grease. oils, and release agents. Roughen as required to remove glaze. If hardeners or sealers have been used to improve curing, use mechanical methods of surface preparation. (c). Wood: Clean surfaces of dirt, oil. and other foreign substances with scrapers. mineral spirits. and sandpaper, as required. Sand surfaces exposed to vic\v smooth and dust off I. Scrape and clean small, dry. seasoned knots, and apply a thin coat of white shellac or other recommended knot sealer before applying primer. After priming, fill holes and imperfections in finish surfaces with putty or plastic \vood filler. Sand smooth when dried. 11. Prime, stain. or seal \vood to be painted immediately on delivery Prime edges, ends, faces, undersides. and hack sides of wood. including cabinets, counters, cases, and paneling. iii. If transparent finish is required, hackprime with spar varnish. IV, Backprime paneling on interior partitions where masonry, plaster, or other wet \vall construction occurs on back side. v Seal tops, bottoms, and cutouts of unprimed \vood doors with a heavy coat of varnish or sealer immediately on delivery. (d). Ferrous Metals: I. Clean ungalvanized ferrous-metal surfaces that have not been shop coated; remove oil. grease, dirt, loose mill scale, and other foreign substances. Use solvent or mechanical cleaning methods that comply \vith SSPC's recommendations. 11. Touch up bare areas and shop-applied prime coats that have been damaged. Wire-brush, clean \vith solvents recommended by paint manufacturer, and touch up \vith same primer as the shop coat. (e). Galvanized Surfaces: 1. Clean galvanized surfaces with non-petroleum-based solvents so surface is free of oil and surface contaminants. Remove pretreatment from galvanized sheet metal fabricated from coil stock by mechanical methods. B. Material Preparation: 1, Maintain containers used in mixing and applying paint in a clean condition, free of foreign materials and residue. PROJECT 3152 SCHEIRMAN ASSOCIATES ARCHITECTS DIVISION 9 PAGE 3 of3 . AMF BOYNTON BEACH LANES SCOPE OF WORK / PAINTING SPECIFICATIONS PROJECT MANlJAI. C. 2. Stir material before application to produce a mixture of uniform density. Stir as required during application. Do not stir surface film into material. If necessary. remove surface film and strain material bet~m~ using. 3 Finish exterior doors on tops, bottoms, and side edges the same as exterior faces. 4 Protect finish surfaces not schedule to paint (such as signage, storefront). Scheduling Painting: Apply first coat to surfaces that have been cleaned, pretreated, or otherwise prepared for painting as soon as practicable after preparation and before subsequent surface deterioration. 1. Omit primer over metal surfaces that have been shop primed and tOllchup painted. 2. If undercoats, stains, or other conditions show through final coat of paint apply additional coats until paint film is llfuniform finish, color, and appearance. D. Application Procedures: Apply paints and coatings by brush, roller, spray, or other applicators according to manufacturer's written instructions. I. Minimum Coating Thickn<:ss: Apply paint materials no thinner than manufacturers' recommended spreading rate. Provide total dry film thickness of the entire sy'stem as recommended by manufacturer. Mechanical and Electrical Work: Painting of mechanical and electrical \vork is limited to items exposed in <:l]uipment rooms and occupied spaces. _1. Block Fillers: Apply block fillers to concrete masonry hlock at a rate to ensure complete coverage with pores filled. 4 Prime Coats: Before applying finish coats, apply a prime coat, as recommended by manufacturer, to material that is required to be painted or finished and that has not been prime coated by others. Recoat primed and sealed surfaces \vhere evidence of suction spots or unsealed areas in first coat appears, to ensure a finish coat with no burn-through or other defects due to insufficient sealing. 5. Pigmented (Opaque) Finishes: Completely cover surfaces as necessary to provide a smooth, opaque surface of uniform finish, color, appearance, and coverage. Cloudiness, spotting, holidays, laps, brush marks, runs, sags, ropiness, or other surface imperfections \vill not be acceptable. CLEANING AND PROTECTIN(; I At the end of each workday, remove empty cans, rags, rubbish, and other discarded paint materials from Project site. Protect work of other trades, whether being paintl:d or noL against damage from painting. Correct damage by cleaning, repairing or replacing, and repainting, as approved by Architect. Provide "Wet Paint" signs to protect nev,,'ly painted finishes. After completing painting operations, remove temporary protective \\:rappings provided by others to protect their work. 4. After work of other trades is complete, touch up and restore damaged or defaced painted surfaces. Comply \\/ith procedures specified in PDCA PI. 7 E. 7 3 END OF SECTION PROJECT 3352 SCHEIRMAN ASSOCIATES ARCHITECTS DIVISION 9 PAGE4of4 PROJECT NAME: AMF ilowling LOCATION: 1190 W. Boynton Beach Blvd. PCN: I FILE NO.: MMSP 04-023 II TYPE OF APPLICATION: I AGENT/CONTACT PERSON: OWNER: Donna Jones Fagundes ADDRESS: ADDRESS: none given FAX: FAX: 954-941-7507 PHONE: - PHONE: 954-941-5605 Cell:954-536-3959 Date of submittal/Proiected meetinl!: dates: SUBMITTAL / RESUBMITTAL 2/13/04 1 ST REVIEW COMMENTS DUE: N/A PUBLIC NOTICE: N/A TRC MEETING: N/A LAND DEVELOPMENT SIGNS POSTED N/A (SITE PLANS): .-,.--- -- PLANNING & DEVELOPMFN"" BOARD N/A MEETING: COMMUNITY REDEVELOPMF.NT N/A AGENCY BOARD CITY COMMISSION MEETING: N/A COMMENTS: S:\Planning\SHARED\WP\PROJECTS\AMF Bowling\2004 PROJECT TRACKING INFO.doc