CORRESPONDENCE
CONGREGACION EL ROSAL, INC.
3636 South Seacrest Boulevard
Boynton Beach, FL 33435
February 21,2006
Reference: EI Rosal Kingdom Hall of Jehovah's Witnesses - Minor Site Plan
Modification
Mr. Ed Breeze, Principal Planner
Planning and Zoning
City of Boynton Beach
100 Boynton Beach Boulevard
Boynton Beach, Florida 33425
Dear Mr. Breeze:
Enclosed please find 4 copies of the proposed construction drawings for the
modifications planned at 3636 South Seacrest Boulevard at the existing Kingdom Hall of
Jehovah's Witnesses.
The following are our responses to your review comments received on May 19,
2005:
1. On the Site and Civil plans, show and identify all necessary traffic control
devices such as stop bars, stop signs, double yellow lane separators striping,
directional arrows and "Do Not Enter" signage, etc. See City Standard
Drawings "K" Series for striping details.
o Traffic control devices are now show on civil sheet CO]
2. Current standards require 9 Y2-ft x 18 Y2-ft parking stalls with a minimum 25-
ft. backup distance for 90 degree parking. Some reduction in backup distance
is allowed for angled parking. See City Standard Detail k -1 for dimensions.
Revise parking layout accordingly.
o Parking stall have been modified to comply with City Detail K-l.
Parking la.vout has been modified accordingly.
3. Provide a Photometric plan. The lighting design shall provide a minimum
average light level of one foot-candle. Include pole wind loading, and pole
C\Docurnents and Settings\hcastro\My Docurnents\RBC\Boynton\L TR _ 2006.0222 .City.siteplan .hcdoc
Erlglfleenng # EB OOOO'::J66j
Mr. Ed Breese
City of Boynton Beach
February 22,2006
details in confonnance with the LDR, Chapter 6, Article IV, Section 11,
Chapter 23, Article 1, Section 5.B.7 and Chapter 23, Article II, Section A on
the Lighting Plan. Lighting shall be directed away from any residential uses
(LDR, Chapter 2, Section 4.N.7.)
o Photometric plan is now included, please see sheet PH. 01. Pole
manufacture to forward wind loading via separate cover.
4. Show sight triangles on the Landscape plans (LDR< Chapter 7.5, Article II,
Section 5.H.). Reference Palm Beach County Standards for the sight triangles
on Seacrest Blvd.
o Comment addressed and incorporated. See LD-l
5. Indicate, by note on the Landscape Plan, that within the sight triangles there
shall be an unobstructed cross-visibility at a level between 2.5' and 8' above
the pavement (LDR, Chapter 7.5, Article II, Section 5.H.).
o Comment addressed and incorporated. See LD-1
6. Provide an engineer's certification on the Drainage Plan as specified in LDR,
Chapter 4, Section 7.F.2.
o Engineer's certification is now included on sheet C 03
7. The LDR, Chapter 6, Article IV, Section 16 requires that all points on each
building will be within 200 feet of an existing or proposed fire hydrant.
Please demonstrate that the plan meets this condition, by showing all
hydrants.
o Existing fire hydrant is located 5 feet to the south of the south
property line. Current survey does not show but we will request
survey locate and show on their drawing.
8. Comprehensive Plan Policy 3C.3.4 requires the conservation of potable
water. As other sources are readily available City water shall not be allowed
for irrigation.
Mr. Ed Breese
City of Boynton Beach
February 22, 2006
o Existing well irrigation system to be used for existing and proposed
landscape areas.
9. Provide written and graphic scales on all sheets.
o Written and graphic scales have been incorporated to all sheets.
10. Add a general note to the Site Plan that all plans submitted for specific
permits shall meet the City's Code requirements at time of application. These
permits include, but are not limited to, the following: paving, grading,
drainage, curbing, site lighting, landscaping and irrigation. Permits required
from other permitting agencies such as Florida Department of Transportation
(FDOT), South Florida Water Management District (SFWMD), Lake Worth
Drainage District (LWDD), Florida Department of Environmental Protection
(FDEP), Palm Beach County Health Department (PBCHD), Palm Beach
County Engineering Department (PBCED), Palm Beach County Department
of Environmental Resource Management (PBCDERM) and others, shall be
included with the permit request.
o General note now included in sheet COl.
11. Full Drainage plans, including drainage calculations, in accordance with the
LDR, Chapter 6, Article IV, Section 5 will be required at the time of
permitting, The provided drainage calculation were briefly reviewed for
general conformance with City of Boynton Beach standards. No obvious
errors were noted and a full review will be done at the time of permit
application.
o Comment noted and drainage calc's resubmitted.
12. Paving, Drainage and Site details will not be reviewed for construction
acceptability at this time. All engineering construction details shall be in
accordance with the applicable City of Boynton Beach Standard Drawings
and the "Engineering Design Handbook and Construction Standards" and will
be reviewed at the time of construction pemlit application.
Mr. Ed Breese
City of Boynton Beach
February 22, 2006
o Comment noted.
13. All trees must be a minimum of 12 feet in height at the time of planting, with
a 3 inch caliper trunk measured at 4.5 feet from the ground. Please correct
the plans to reflect this requirement.
o Comment addressed and incorporated. See LD-l
14. Trees are to be placed every 30 lineal feet around and within parking areas.
Please correct the plans to reflect this requirement.
o Comment addressed and incorporated. See LD-l
15. All shrubs must be a minimum of 24 inches tall with 24 inch spread and
planted with the branches touching to form a dense hedge at time of planting.
Please correct the plans to reflect this requirement.
o Comment addressed and incorporated. See LD-l
16. Palms must be planted in clusters ofthree at varying height not less than 12
feet to satisfy the requirement of one shade tree. Please correct the plans to
reflect this requirement.
o New palms will not be planted within the property.
17. No dimension is provided for the front landscape buffer along Seacrest
Boulevard. The code requires a minimum of 7 feet, with two colorful shrub
species planted in continuous rows and a combination of colorful shrubs
between the hedge material and the property line. Please correct he plans to
reflect this requirement.
o Comment addressed and incorporated. See LD-l
18. The code requires the planting of signature trees at the entrances and exists of
properties. They include Yellow Elder, Tibouchina Granulosa, and
Bougainvillea. Please correct the plans to reflect these requirements.
o Comment addressed and incorporated. See LD-
19. Mulch shall be placed at a minimum depth of 3 inches and shall not be of a
cypress variety. Please correct the plans to reflect this requirement.
Mr. Ed Breese
City of BoyntoIl Beach
February 22,2006
o Comment addressed and incorporated. See LD-l
20. The Landscape Plan should identify where on the site each of the plant
materials noted on the landscape schedule are being planted. Please correct
the plans to reflect the requirement.
o Comment addressed and incorporated. See LD-l
21. The hedge depicted on the north side of the property should be continued
along the parking area, all the way to the west property line. Please correct
the plans to reflect this requirement.
o Comment addressed and incorporated. See LD-l
22. A detail of the plantings around the monument sign was not provided. Two
colorful shrub varieties and colorful groundcover is required around signs.
Please correct the plans to reflect this requirement.
o Comment addressed and incorporated. See LD-l
23. No detail of the shed to be placed at the SE corner was provided. Sheds may
be no larger than 100 square feet, 7 feet in height and must be a minimum of
3 feet from any property line. Please provide these details.
o Cut sheet provided for shed to be provided under separate cover.
24. No elevations of the building were provided depicting the enclosing the 30
square feet of building at the SE corner. Please provide these details,
including materials to be used, materials ofthe rest of the structure and if the
color will match the existing paint.
o Enclosure of the SE corner is no longer requested. Plans have been
modified to delete this change.
25. All comments requiring changes and/or corrections to the plans shall be
reflected on all appropriate sheets.
o Comment noted.
Mr. Ed Breese
City of Boynton Beach
February 22,2006
26. Please note that changes or revisions to these plans may generate additional
comments. Acceptance of these plans during the modification process does
not ensure that additional comments may not be generated.
o Comment noted.
Should you have any questions or comments please do not hesitate to contact us at your
convemence.
Since ely,
(~
Congregaci6n E~nc.
Luis Lopez
President
Cc: Roger Maki - GRW Architecture
Mike Kowalchuk - Regional Building Committee of Jehovah's Witnesses
TO:
Page 1 of3
Breese, Ed
From: Coale, Sherie
Sent: Tuesday, March 28, 20064:31 PM
To: Breese, Ed
Subject: FW: EI Rosal Kingdom Hall of Jahovah's Witnesses, Minor Site Plan Mod. 2nd Rev. Comments FYI
-----Original Message-----
From: Kribs, Carol
Sent: Tuesday, March 28, 2006 4:30 PM
To: Livergood, Jeffrey; Kelley, David; Hall, Ken
Cc: Coale, Sherie
Subject: EI Rosal Kingdom Hall of Jahovah's Witnesses, Minor Site Plan Mod. 2nd Rev. Comments FYI
TO:
Ed Breese, Principal Planner, Planning and Zoning
FROM:
Laurinda Logan, P.E., Senior Engineer
DATE:
March 28, 2006
RE:
Review Comments
Minor Site Plan Modification - 2nd Review
EI Rosal Kingdom Hall of Jehovah's Witnesses
File No. MMSP 05-033
The above referenced Site Plans, received on March 13, 2006, were reviewed against the 15t Review
Comments, dated May 19, 2006, and for Public Works, Engineering, and Utilities against the
requirements outlined in the City of Boynton Beach Code of Ordinances. Following are our comments
with the appropriate Code and Land Development Regulations (LOR) referenced.
PUBLIC WORKS - GENERAL
1. An Orange Geiger is proposed on the southwest corner of the dumpster enclosure, creating a
vertical conflict for Solid Waste trucks attempting to pick up trash. Please relocate this tree or
replace with a non-canopy tree species.
PUBLIC WORKS - TRAFFIC
(i) On the Site and Civil plans, show and identify all necessary traffic control devices such as stop
bars, stop signs, double yellow lane separators striping, directional arrows and "Do Not Enter"
signage, etc. See City Standard Drawings "K" Series for striping details.
ENGINEERING
( 3. ) All comments requiring changes and/or corrections to the plans shall be reflected on all appropriate
V sheets.
( 4. ') Please note that changes or revisions to these plans may generate additional comments.
\:! Acceptance of these plans during the modification process does not ensure that additional
comments may not be generated at permit review.
4/512006
TO:
Page 2 0[3
(j) Provide written and graphic scales, as well as a north arrow, on all scaled drawings.
Q Show sight triangles on the Landscape plans (LDR, Chapter 7.5, Article II, Section 5.H.).
V Reference Palm Beach County Standards for the sight triangles on Seacrest Blvd.
7. There are overhead power lines around the perimeter of the church property. Landscaping shall be
designed and installed in accordance with FPL's "Plant the Right Tree in the Right Place".
Department of Public Works/Engineering Division Memo #06-037
Re: EI Rosal Kingdom Hal of Jehovah's Witnesses, Minor Site Plan Modification - 2nd Review
March 28, 2006
Page 2
8. Specify a cultivar such as High-Rise or Cathedral for the Live Oaks proposed adjacent to drive
aisles to minimize the potential for vertical conflicts for high profile vehicles.
@ Full drainage plans, including drainage calculations, in accordance with the LDR, Chapter 6, Article
IV, Section 5 will be required at the time of permitting. The provided drainage calculations were
briefly reviewed for general conformance with City of Boynton Beach standards. No obvious errors
were noted and a full review will be done at the time of permit application.
~paving, Drainage and Site details will not be reviewed for construction acceptability at this time. All
l7 engineering construction details shall be in accordance with the applicable City of Boynton Beach
Standard Drawings and the "Engineering Design Handbook and Construction Standards" and
will be reviewed at the time of construction permit application.
UTILITIES
Gcomprehensive Plan Policy 3.C.3.4. requires the conservation of potable water. As other sources
are readily available City water shall not be allowed for irrigation. Please identify the irrigation
source on the plans.
LUck
Cc: Jeffrey R. Livergood, P.E., Director, Public Works (via e-mail)
Peter V. Mazzella, Deputy Utility Director, Utilities
H. David Kelley, Jr., P.E./ P.S.M., City Engineer, Public Works/Engineering (via e-mail)
Glenda Hall, Maintenance Supervisor, Public Works/Forestry & Grounds Division
Larry Quinn, Solid Waste Manager, Public Works/Solid Waste
Kenneth Hall, Engineering Plans Analyst, Public Works/Engineering (via e-mail)
File
4/512006
'f.b.e Citu 01 Bounton Beach
DEVELOPMENT DEPARTMENT
PLANNING AND ZONING DIVISON
100 E. Boynton Beach Boulevard
P.O. Box 310
Boynton Beach, Florida 33425-0310
TEL: 561-742-6260
FAX: 561-742-6259
www.boynton-beach.org
May 19, 2005
Mr. Luis Lopez
EI Rosal Congregation
3636 S. Seacrest Blvd.
Boynton Beach, F133435
Re: E1 Rosal Congregation of Jehovah's Witnesses, Inc.
Dear Mr. Lopez:
The City of Boynton Beach staff has reviewed the revisions to your plans for the above-mentioned
project. The following comments are being forwarded to you for your review and response:
t..-- f0 On the Site and Civil plans, show and identify all necessary traffic control devices such as
V stop bars, stop signs, double yellow lane separators striping, directional arrows and "Do Not
_ ~nter" signage, etc. See City Standard Drawings "K" Series for striping details.
V ~urrent standards require 9'li-ft. x 18Y2-ft. parking stalls with a minimum 25-ft. backup
distance for 900 parking. Some reduction in backup distance is allowed for angled parking.
~ See City Standard Detail K-l for dimensions. Revise parking layout accordingly.
U P-w'.'iae R Plu~tometric~ The lightiug ae~ll :sha'll pruvidt: a minimum averagt: lighllevel
of Otlf' f()ot-C::lndl~ Include pole wind loading, and pole details in conformance with the
LDR, Chapter 6, Article IV, Section 11, Chapter 23, Article I, Section 5.B.7 and Chapter 23,
Article II, Section A on the Lighting PIan. l..igJ->tiRg shall 9@ directed away fnJ111 any
Q ~idential uses (1 .DR. rh~pter 2, S~{,t~o1l4.N.7.)
~ 4 Show sight triangles on the Landscape plans (LDR, Chapter 7.5, Article II, Section 5.H.).
. ~ Reference Palm Beach County Standards for the sight triangles on Seacrest Blvd.
V V Indicate, by note on the Landscape Plan, that within the sight triangles there shall be an
unobstructed cross-visibility at a level between 2.5' and 8' above the pavement (LDR,
It:A~hapter 7.5, Article II, Section 5.H.).
~ ~rovide an engineer's certification on the Drainage Plan as specified in LDR, Chapter 4,
Section 7.F.2.
V'The LDR, Chapter 6, Article IV, Section 16 requires that all points on each building will be
within 200 feet of an existing or proposed fire hydrant. Please demonstrate that the plan
meets this condition, by showing all hydrants.
/, @ Comprehensive Plan Policy 3.C.3.4. requires the conservation of potable water. As other
1:'\ sources are readily available City water shall not be allowed for irrigation.
L.-- 1.V Provide written and graphic scales on all sheets.
. .
. Page 2 April 5, 2006
1 ~d a general note to the Site Plan that all plans submitted for specific permits shall meet the
V' 2~ty's Code requirements at time of application. These permits include, but are not limited
to, the following: paving, drainage, curbing, site lighting, landscaping and irrigation. Permits
required from other permitting agencies such as Florida Department of Transportation
(FDOT), South Florida Water Management District (SFWMD), Lake Worth Drainage
District (LWDD), Florida Department of Environmental Protection (FDEP), Palm Beach
County Health Department (PBCHD), Palm Beach County Engineering Department
(PBCED), Palm Beach County Department of Environmental Resource Management
dBCDERM) and any others, shall be included with the permit request.
&~A ull Drainage plans, including drainage calculations, in accordance with the LDR, Chapter 6,
Article IV, Section 5 will be required at the time of permitting. The provided drainage
calculations were briefly reviewed for general conformance with City of Boynton Beach
standards. No obvious errors were noted and a full review will be done at the time of permit
application.
~aving, Drainage and Site details will not be reviewed for construction acceptability at this
~ime. All engineering construction details shall be in accordance with the applicable City of
Boynton Beach Standard Drawings and the "Engineering Design Handbook and
Construction Standards" and will be reviewed at the time of construction permit
application.
~ (i3)\1l trees must be a minimum of 12 feet in height at the time of planting, with a 3 inch caliper
~trunk measured at 4.5 feet from the ground. Please correct the plans to reflect this
'1~ requirement.
~ Trees are to be placed every 30 lineal feet around and within parking areas. Please correct the
1 ,..ylans to reflect this requirement.
? ~ll shrubs must be a minimum of 24 inches tall with 24 inch spread and planted with the
branches touching to form a dense hedge at time of planting. Please correct the plans to
reflect this requirement.
~alms must be planted in clusters ofthree at varying height not less than 12 feet to satisfy the
~uirement for one shade tree. Please correct the plans to reflect this requirement.
. . No dimension is provided ofthe front landscape buffer along Seacrest Boulevard. The code
requires a minimum of7 feet, with two colorful shrub species planted in continuous rows and
a combination of colorful shrubs between the hedge material and the property line. Please
1 ~orrect the plans to reflect this requirement.
VO. ~he code requires the planting of signature trees at the entrances and exits of properties. They
include Yellow Elder, Tibouchina Granulosa, and Bougainvillea. Please correct the plans to
_ yflect this requirement.
~. Mulch shall be place at a minimum depth of 3 inches and shall not be of a cypress variety.
~se correct the plans to reflect this requirement.
. The Landscape Plan should identify where on the site each ofthe plant materials noted on the
" ~ ~ndscape schedule are being planted. Please correct the plans to reflect this requirement.
vA' The hedge depicted on the north side ofthe property should be continued along the parking
,,/ea, all the way to the west property line. Please correct the plans to reflect this requirement.
VL. ~ detail of the plantings around the monument sign was not provided. Two colorful shrub
varieties and colorful groundcover is required around signs. Please correct the plans to reflect
SiS requirement.
23. 0 detail of the shed to be placed at the SE comer was provided. Sheds may be no larger
than 100 square feet, 7 feet in height and must be a minimum of 3 feet from any property
line. Please provide these details.
V~v7'
~~~
~,4o
..
. .
. Page 3 April 5, 2006
~o elevations of the building were provided depicting the enclosing the 30 square feet of
building at the SE corner. Please provide these details, including materials to be used,
materials of the rest of the structure and if the color will match the existing paint.
QAll comments requiring changes and/or corrections to the plans shall be reflected on all
Vappropriate sheets.
@ Please note that changes or revisions to these plans may generate additional comments.
Acceptance of these plans during the modification process does not ensure that additional
comments may not be generated at permit review.
Please submit revised plans reflecting the changes discussed above to continue the review of your
request through the process. Do not hesitate to contact me with any questions or ifthere is anything I
can do to assist you.
Sincerely,
Ed Breese
Principal Planner
cc: Karen Main, Plan Review Analyst
Laurinda Logan, Senior Engineer
-
~r ~ Pte<.4S ~
--
u-ti1
U -#/
---
~ /::'''' . ~ _I
~(S:-~l ' ' I: 1VE .1 ~~ .. -. ..' ....
~llLrf,l -'-." .... '
~.r, L --'---. ' , .', _.
- - ~' ~
i--- --- ... , ·
'- _ _-~~ .G4\" I-
~~......". . ,~_.
~i.\ "\---- '~- ~~
. ". ..D ~~ '-,
..... It. ',i~ ,~
.'. " E=.~>~ ~~,~ : I~
.- i'~. ;~
r=...- I ' '
. 1_.. 1= :1 : : :1
I~:. I:'
1 f"'"'",. . ---=-'- !
,~'. i
~."".. ,'I:
._i- 'i
". ! . i
".4-:f "II~~'': .'1 i, I
, -
.-:'-I-,I.~~~.:- I \
u. ,i.. · '1: I
.... :.1.-........... ' !
. I i 110.... " II... ...... : I,
=." (:) 0 · 0.."
i --= I :
~.: __ III. .......... i
....-... ......_. ==-
.. .
.1 1"-_ .~ · II
~ -I. I... ': . : I~I:I: ~. '
lip I 1-
Ali- 1....1". .: L-
.
Q5
~
C!
o
o
C'")
II
.5
.....
-
-
...
co
I
E
o
""C
C)
C
.-
~
-
. - . .. m _
,
.-- r
) --0
~\' I.
II
.. 10
:J P a.
.1.1 f---
--
_ d~
~ I', --
.---\;..
. . .. '.
.'
co
en
o
c:::
-
w
......
T
------
-
-
-
f---- z.~
I--- _
I--- ..~ ~
I I
. I----
I I
, ,
i I
I..
..~ ~
\
" .)
~
\.
Drainage Calculations
EI Rosal Kingdom Hall of Jehovah's Wrtnesses
Boynton Beach, FL
~ t'"
~~l/~i)'"
PRE-DEVELOPMENT
Pre Development
DATE:
02/22/2006
EI Rosal Kingdom Hall
Site Data
Acreages
1 Total Site Area =
2. Drainage Project Area=
3. Impervious
Buildings (Roof)=
Roads and Parking=
4. Lakes=
5. Pervious=
0.8348 Acres
0.8348 Acres
0.0759 Acres
0.4380 Acres
0.0000 Acres
0.3209 Acres
Water Level Elevations
1. Wet Season Water Table =
2. Average Water Table Elevation=
3. Average Site Elevation=
4. Average depth of Water Table=
5. Soil Storage =
12.00
10.00
25.00
15.00
8.18
Ft. NGVD
Ft. NGVD
Ft. NGVD
Ft.
inches
Rainfall
10 year one day - 7.72 Inches 10 year three day - 10.49 Inches
25 year one day - 10.00 Inches 25 year three day - 13.59 Inches
100 year one day - 12.14 Inches 100 year three day - 16.50 Inches
SCS Curve Number
The Average depth to the water table=
Average Site Grade - Av. Water Table =
25.00 10.00 =
Maximum 4 Ft. of Storage is assumed
15.00 Ft.
4.00 Ft. of storage Depth
Available Soil Storage:
Soil Storage x Pervious Area x1 FU12 Inches
8.18 x 0.32 x 1/12 =
0.22 AC.Ft. Available soil storage onsite
Convert available soil storage onsite per site area
0.22 1 0.83 x12in/Ft=
3.14 in. of site wide soil storage, S
SCS Curve Number, CN
CN 1000/(S + 10)
10001 ( 3.14 +10) =
76.08 SCS Curve Number
KNOWN SITE INFORMATION:
Drainage Area =36,363 SF = 0.83 Acres
Page 1 of 2
Pre Development
DATE:
02/22/2006
EI Rosal Kingdom Hall
10-YR TOTAL TOTAL
STORM RUNOFF RUNOFF
EVENTS P I CN I S I Q VOLUME VOLUME
(duration,HR (inches) I I (runoff,inche~ (cf) (AC-FT))
72
I 10.49 I 76.1
7.48 l 22662 I 0.520 I
3.14
25-YR TOTAL TOTAL
STORM RUNOFF RUNOFF
EVENTS P I CN I S I Q VOLUME VOLUME
(duration,HR (inches) I I (runoff,inche~ lcf) (AC-FT))
72
I 13.59 I 76.1
3.14
10.43 l 31608 I 0.726 I
Page 2 of 2
POST DEVELOPMENT
Post Development
DATE:
02/22/2006
EL ROSAL KINGDOM HALL
Site Data
Acreages
1 Total Site Area =
2. Drainage Project Area=
3. Impervious
Buildings (Roof)=
Roads and Parking=
4. Lakes=
5. Pervious=
0.8348 Acres
0.8348 Acres
0.0760 Acres
0.4970 Acres
0.0000 Acres
0.2618 Acres
Water Level Elevations
1. Wet Season Water Table =
2. Average Water Table Elevation=
3. Average Site Elevation=
4. Average depth of Water Table=
5. Soil Storage =
12.00
10.00
25.00
15.00
8.18
Ft. NGVD
Ft. NGVD
Ft. NGVD
Ft.
inches
Rainfall
10 year one day - 7.72 Inches 10 year three day - 10.49 Inches
25 year one day - 10.00 Inches 25 year three day - 13.59 Inches
100 year one day - 12.14 Inches 100 year three day - 16.50 Inches
Design Criteria
A. Pre vs Post Development discharge net zero
B.
Existing front of property will drain through historical patterns out to Seacrest Blvd, the new rear
parking area will drain to an exfiltration trench.
Page 1 of 2
Post Development
DATE:
02/22/2006
EL ROSAL KINGDOM HALL
SCS Curve Number
The Average depth to the water table=
Average Site Grade - Av. Water Table =
25.00 10.00 =
Maximum 4 Ft. of Storage is assumed =
15,00 Ft.
4.00 Ft. of storage Depth
Available Soil Storage:
Soil Storage x Pervious Area x1 FU12 Inches
8.18 x 0.26 x1/12=
0.18 AC.Ft. Available soil storage onsite
Convert available soil storage onsite per site area
0.18 1 0.83 x12in/Ft=
2.57 in. of site wide soil storage, S
SCS Curve Number, CN
CN 1000/(S + 10)
10001 ( 2.57 +10) =
79.58 SCS Curve Number
SUMMARY
KNOWN SITE INFORMATION:
Drainage Area =36,363 SF = 0.83 Acres
10-YR TOTAL TOTAL
STORM RUNOFF RUNOFF
EVENTS P I CN I S I Q VOLUME VOLUME
(duration,HR (inches) I I (runoff,inche~ (cf) (AC-FT))
7.94 I 24054 I 0.552 I
I 10.49 I 79.6
2.57
72
25-YR TOTAL TOTAL
STORM RUNOFF RUNOFF
EVENTS P I CN I S I Q VOLUME VOLUME
(duration,HR (inches) I I (runoff,inchel (cf) (AC-FT))
72
13.59 I 79.6
0.761
10.93 I 33128
2.57
Page 2 of 2
Post Development
FRENCH DRAIN CALCULATIONS:
L= V/[K(H2W+2H2Du-Du^2+2H2Ds )+(0.000139WDu)]
Formula is per South Florida Water Management District Manual Volume IV
=
104.97 FT.
1.56 ACRE-INCH
0.1303 ACRE-FT.
6.00 FT.
0.000170 CFS/FT^2-FT.HEAD
6.00 FT.
4.00 FT.
0.00 FT.
L= Length of Trench
V= Volume Treated
V1= Volume Treated
W= Width Of Trench
K= Hydraulic Conductivity
H2= Depth to the Water Table
Du= Non-saturated Trench Depth (feet)
Ds= Saturated Trench Depth (feet)
=
=
=
=
=
=
=
VOLUME TREATED IN PROPOSED FRENCH DRAIN IS =
0.1303 ACRE-FT.
FRQM.:LUIS A LOPEZ PE
FAX NO. :551 735 4295
~Eh. 08 2005 07:29AM Pi
"
, . ~ ',T~sting lablJl: tlj_:,palm':B~acb8s,lnc~'
GEOTECHNICAL. ENy!B-9NMr;NTAl.~ :CONTRACT DRIL~rf':l(; "CON~UL. TING ENG.INEERING * TESTING" INSPECTIONS
". .
. 9NiiD -UBUALCONDITION TEaT
'. . . - ,
. .
Client:'
, . "Luis topez ..
. ~. ',:TLPB li'ile No..;._.,...~~.__:, 04/25'7-2 ,:. ,
, '. Date:Test Perlormed~ . 10It 1(04
. ProjeCt Location:: '3.:6~6 S. 'Seacrest Blvd:
... ' , .. 8?yritOIl Be&:h, ;FL
. . . .
,','Perl'oi-med by"~:..~......: '. CS/DB.
',' I
. -' " ~ ., ",..
-... ',' -:- ''';'-7:';:::'-.TEST''N:Ul\IB~R:' ',:UC:r~ - - .--,: . :. .._C~_~ _ " -,. .. _' "~, '.;-~, ,_.. c....:..~_ . "....'-': :,. . ,.-
:", ',,:.. ,: " ,L'OCATiON: 41'W'ofBackFence. 34' S'ofNorth-Fence Line " .
, . <
.'
"..... oJ. \
~ :
., ..
..' ., " .' ..
" DEPTH .. SOIL, DEScRIPTION
; ".N' '.
, '. ,',. ., .' . . '. .
'. ., '. .,
.' ,..
OJ)','::" ,O~l" ',er6~Fine' 8~d (SP) '. , .,
.. " ,
, .. ,. ..
: 0.1'."-'5.5', " ~.tight B~o~ F me Sand (SP) ,
.. . .
'.
,. .. ,.
E~d.of A1,i.ger Water Table Not Ei},countered'.. .., .. .. - "
.,: '. .
,. . ~, . -
.1 . I .' .
. . ~.,
. "
',,-,'
'. "
. ,.' : ,;\
'"
)... . -'. .
, , 'PERMEABlJ,iIY RESuLT~ . .,: .
. .. .-' . ,.,
, .
, ;.
:. ..
'\ .>,~
" .
., f. ' ,.',:A VE:Rr\GE,'(i= '~t:006.' 95'~.f~ ,:',. iut.. ':':It .~t.7 :x.,'lo-~ CFslFfi'~ Ft H~ad....-
.. " ..< IV '... .....'
. ,".'
. ",' ~', ' .' .
., ,,'
, "
..'~ \, ',' "', .,' .
,,',.':. '" ,(;ASED'Oa.-UNCASED,;.,.,Cased.Q"'
,.." . 'C4ING:D~PTiI:. ': ':, ,'Tf~f'
,',
. ,,::Ht)LE'D~TER: ..
:', . '; , ,:,';:', DEPtH':QI?,:Hd~~~
. " ~.", ,
.,:,'
.', .
.' .
.. ", .C " .
, 6: iIiches "
<. 7reet,'
. , ' .
..': NOTES: , ,: ...', .".':.: '. ': .,. ,. '., ... '. , ",
. ._,~, ~ t~~t:l?~~edufg~ ~~.!(co~~JlC~JQ:'gene~ ~cordai1~e ~,f!l, Qle'~atest'South;Flbrid(Water
'. 'Managem~nt :District Re~atory Criteria UsUal Condition ~est Procedures.. ,'.: .. , ' .
' : " '. The ~ater ~~bl~ ~ep~:~;~~e ~st~~,:ior'th~'.~~O~d.sti~ace to the ~ater ~ble'b~~ore the ad'clition -or"
.".water~. " " ' . . ..
....
. . :r
'. .
. ."" ,
. ..
. '
. - - - . .
. ,
. ,
, .' .' Respertfully su~mitted,. . ' ". . '. '
. TESTING LAI(-OF:THE,PALM BEACHES. INC. ..
. , . . .', '. . - \ . .
~,~,,~-~o~,... . .,'B*;,__:,~~~:' .',
.. ,: :,' . . ~ .... ":. . : . ~ . ',.:-. . \; . ". .' '. .,' " I ~ ".l . .
..'~~9FESSlbNAL.ENGI,~EE,~ING 's~RyicEs:.TH~bU,GHOU! '~OUTH FLORIDA SH~~CE 1961 .
", .' . ,d?1 ~n "HII ~tro.c"t t=>>:n "R.n'''; ?1'1 I ~""'a" \AI............. I::~''''.:i...n. .,.,.".\~'^ .,.."..:.~ _ ,~;..... .......:- =--..:. _" . ~_'_.. .:... _ ., ,
~ I"" ,
~ .
EI Rosal Kingdom Hall
Boynton Beach, FL
PRE DEVELOPMENT VS POST DEVELOPMENT SUMMARY
PRE DEVELOPMENT POST DEVELOPMENT % CHANGE
Impervious Area 0.5139 acres 0.573 acres (+) 3.1
Pervious Area 0.3209 acres 0.2618 acres (-) 3.1
SCS Curve 76 80
Soil Storage 3.14 inches 2.57 inches
French Drain Storage 0 acre-ft 0.13 acre-ft
10y 3d Discharge, Q 0.52 cfs 0.552 cfs (+) 0.1
25y 3d Dischage, Q 0.726 cfs 0.761 cfs (+) 0.1
Net increase is zero because of storage provided in exfiltration trench.
...
The Citu 01 BoUl1tOl1 Bear!lt
DEVELOPMENT DEPARTMENT
PLANNING AND ZONING DMSON
100 E. Boynton Beach Boulevard
P.O. Box 310
Boynton Beach, Florida 33425-0310
TEL: 561-742-6260
FAX: 561-742-6259
www.boynton-beach.org
May 19, 2005
Mr. Luis Lopez
EI Rosal Congregation
3636 S. Seacrest Blvd.
Boynton Beach, FI 33435
Re: EI Rosal Congregation of Jehovah's Witnesses, Inc.
Dear Mr. Lopez:
The City of Boynton Beach staffhas reviewed the revisions to your plans for the above-mentioned
project. The following comments are being forwarded to you for your review and response:
1. On the Site and Civil plans, show and identify all necessary traffic control devices such as
stop bars, stop signs, double yellow lane separators striping, directional arrows and "Do Not
Enter" signage, etc. See City Standard Drawings "K" Series for striping details.
2. Current standards require 9'i'2-ft. x 18'i'2-ft. parking stalls with a minimum 25-ft. backup
distance for 900 parking. Some reduction in backup distance is allowed for angled parking.
See City Standard Detail K-l for dimensions. Revise parking layout accordingly.
3. Provide a Photometric plan. The lighting design shall provide a minimum average light level
of one foot-candle. Include pole wind loading, and pole details in conformance with the
LDR, Chapter 6, Article N, Section 11, Chapter 23, Article I, Section 5.B.7 and Chapter 23,
Article II, Section A on the Lighting Plan. Lighting shall be directed away from any
residential uses (LDR, Chapter 2, Section 4.N.7.)
4. Show sight triangles on the Landscape plans (LDR, Chapter 7.5, Article II, Section 5.H.).
Reference Palm Beach County Standards for the sight triangles on Seacrest Blvd.
5. Indicate, by note on the Landscape Plan, that within the sight triangles there shall be an
unobstructed cross-visibility at a level between 2.5' and 8' above the pavement (LDR,
Chapter 7.5, Article II, Section 5.H.).
6. Provide an engineer's certification on the Drainage Plan as specified in LDR, Chapter 4,
Section 7.F.2.
7. The LDR, Chapter 6, Article N, Section 16 requires that all points on each building will be
within 200 feet of an existing or proposed fire hydrant. Please demonstrate that the plan
meets this condition, by showing all hydrants.
8. Comprehensive Plan Policy 3.C.3.4. requires the conservation of potable water. As other
sources are readily available City water shall not be allowed for irrigation.
9. Provide written and graphic scales on all sheets.
It
. Page 2
May 19, 2005
10. Add a general note to the Site Plan that all plans submitted for specific permits shall meet the
City's Code requirements at time of application. These permits include, but are not limited
to, the following: paving, drainage, curbing, site lighting, landscaping and irrigation. Permits
required from other permitting agencies such as Florida Department of Transportation
(FDOT), South Florida Water Management District (SFWMD), Lake Worth Drainage
District (L WDD), Florida Department of Environmental Protection (FDEP), Palm Beach
County Health Department (PBCHD), Palm Beach County Engineering Department
(PBCED), Palm Beach County Department of Environmental Resource Management
(PBCDERM) and any others, shall be included with the permit request.
11. Full Drainage plans, including drainage calculations, in accordance with the LDR, Chapter 6,
Article IV, Section 5 will be required at the time of permitting. The provided drainage
calculations were briefly reviewed for general conformance with City of Boynton Beach
standards. No obvious errors were noted and a full review will be done at the time of permit
application.
12. Paving, Drainage and Site details will not be reviewed for construction acceptability at this
time. All engineering construction details shall be in accordance with the applicable City of
Boynton Beach Standard Drawings and the "Engineering Design Handbook and
Construction Standards" and will be reviewed at the time of construction permit
application.
13. All trees must be a minimum of 12 feet in height at the time of planting, with a 3 inch caliper
trunk measured at 4.5 feet from the ground. Please correct the plans to reflect this
requirement.
14. Trees are to be placed every 30 lineal feet around and within parking areas. Please correct the
plans to reflect this requirement.
15. All shrubs must be a minimum of24 inches tall with 24 inch spread and planted with the
branches touching to form a dense hedge at time of planting. Please correct the plans to
reflect this requirement.
16. Palms must be planted in clusters ofthree at varying height not less than 12 feet to satisfy the
requirement for one shade tree. Please correct the plans to reflect this requirement.
17. No dimension is provided ofthe front landscape buffer along Seacrest Boulevard. The code
requires a minimum of7 feet, with two colorful shrub species planted in continuous rows and
a combination of colorful shrubs between the hedge material and the property line. Please
correct the plans to reflect this requirement.
18. The code requires the planting of signature trees at the entrances and exits of properties. They
include Yellow Elder, Tibouchina Granulosa, and Bougainvillea. Please correct the plans to
reflect this requirement.
19. Mulch shall be place at a minimum depth of 3 inches and shall not be of a cypress variety.
Please correct the plans to reflect this requirement.
20. The Landscape Plan should identify where on the site each of the plant materials noted on the
landscape schedule are being planted. Please correct the plans to reflect this requirement.
21. The hedge depicted on the north side of the property should be continued along the parking
area, all the way to the west property line. Please correct the plans to reflect this requirement.
22. A detail of the plantings around the monument sign was not provided. Two colorful shrub
varieties and colorful groundcover is required around signs. Please correct the plans to reflect
this requirement.
23. No detail of the shed to be placed at the SE corner was provided. Sheds may be no larger
than 100 square feet, 7 feet in height and must be a minimum of 3 feet from any property
line. Please provide these details.
. Page 3
May 19, 2005
24. No elevations of the building were provided depicting the enclosing the 30 square feet of
building at the SE comer. Please provide these details, including materials to be used,
materials of the rest of the structure and if the color will match the existing paint.
25. All comments requiring changes and/or corrections to the plans shall be reflected on all
appropriate sheets.
26. Please note that changes or revisions to these plans may generate additional comments.
Acceptance of these plans during the modification process does not ensure that additional
comments may not be generated at permit review.
Please submit revised plans reflecting the changes discussed above to continue the review of your
request through the process. Do not hesitate to contact me with any questions or ifthere is anything I
can do to assist you.
Sincerely,
Ed Breese
Principal Planner
cc: Karen Main, Plan Review Analyst
Laurinda Logan, Senior Engineer