REVIEW COMMENTS DEPARTMENT OF PUBLIC WORKS ENGINEERING DIVISION MEMORANDUM NO. 06-037 TO: Ed Breese, Principal Planner, Planning and Zoning FROM: Laurinda Logan, P.E., Senior Engineer DATE: March 28, 2006 RE: Review Comments Minor Site Plan Modification - 2nd Review EI Rosal Kingdom Hall of Jehovah's Witnesses File No. MMSP 05-033 The above referenced Site Plans, received on March 13, 2006, were reviewed against the 1 st Review Comments, dated May 19, 2006, and for Public Works, Engineering, and Utilities against the requirements outlined in the City of Boynton Beach Code of Ordinances. Following are our comments with the appropriate Code and Land Development Regulations (LOR) referenced. PUBLIC WORKS - GENERAL 1. An Orange Geiger is proposed on the southwest corner of the dumpster enclosure, creating a vertical conflict for Solid Waste trucks attempting to pick up trash. Please relocate this tree or replace with a non-canopy tree species. PUBLIC WORKS - TRAFFIC 2. On the Site and Civil plans, show and identify all necessary traffic control devices such as stop bars, stop signs, double yellow lane separators striping, directional arrows and "Do Not Enter" signage, etc. See City Standard Drawings "K" Series for striping details. ENGINEERING 3. All comments requiring changes and/or corrections to the plans shall be reflected on all appropriate sheets. 4. Please note that changes or revIsions to these plans may generate additional comments. Acceptance of these plans during the modification process does not ensure that additional comments may not be generated at permit review. 5. Provide written and graphic scales, as well as a north arrow, on all scaled drawings. 6. Show sight triangles on the Landscape plans (LOR, Chapter 7.5, Article II, Section 5.H.). Reference Palm Beach County Standards for the sight triangles on Seacrest Blvd. 7. There are overhead power lines around the perimeter of the church property. Landscaping shall be designed and installed in accordance with FPL's "Plant the Right Tree in the Right Place". ~ Department of Public Works/Engineering Division Memo #06-037 Re: EI Rosal Kingdom Hal of Jehovah's Witnesses, Minor Site Plan Modification - 2nd Review March 28, 2006 Page 2 8. Specify a cultivar such as High-Rise or Cathedral for the Live Oaks proposed adjacent to drive aisles to minimize the potential for vertical conflicts for high profile vehicles. 9. Full drainage plans, including drainage calculations, in accordance with the LOR, Chapter 6, Article IV, Section 5 will be required at the time of permitting. The provided drainage calculations were briefly reviewed for general conformance with City of Boynton Beach standards. No obvious errors were noted and a full review will be done at the time of permit application. 10. Paving, Drainage and Site details will not be reviewed for construction acceptability at this time. All engineering construction details shall be in accordance with the applicable City of Boynton Beach Standard Drawings and the "Engineering Design Handbook and Construction Standards" and will be reviewed at the time of construction permit application. UTILITIES 11. Comprehensive Plan Policy 3.C.3.4. requires the conservation of potable water. As other sources are readily available City water shall not be allowed for irrigation. Please identify the irrigation source on the plans. LUck Cc: Jeffrey R. Livergood, P.E., Director, Public Works (via e-mail) Peter V. Mazzella, Deputy Utility Director, Utilities H. David Kelley, Jr., P.E./ P.S.M., City Engineer, Public Works/Engineering (via e-mail) Glenda Hall, Maintenance Supervisor, Public Works/Forestry & Grounds Division Larry Quinn, Solid Waste Manager, Public Works/Solid Waste Kenneth Hall, Engineering Plans Analyst, Public Works/Engineering (via e-mail) File S:\Engineering\Kribs\EI Rosal Kingdom Hall of Jahovah's Witnesses, Minor Site Plan Mod. 2nd Rev..doc DEPARTMENT OF PUBLIC WORKS ENGINEERING DIVISION MEMORANDUM NO. 05-060 TO: Ed Breese, Principal Planner, Planning and Zoning DATE: May 17, 2005 ( FROM: Laurinda Logan, P.E., Senior Engineer RE: Review Comments \ Minor Site Plan Modification - 1 st Revi EI Rosal Kingdom Hall of Jehovah's Witnesses File No. MMSP 05-033 The above referenced Site Plans, received on May 12, 2005, was reviewed for Public Works, Engineering, and Utilities against the requirements outlined in the City of Boynton Beach Code of Ordinances. Following are our comments with the appropriate Code and Land Development Regulations (LOR) referenced. PUBLIC WORKS - GENERAL No comments at this time. PUBLIC WORKS - TRAFFIC 1. On the Site and Civil plans, show and identify all necessary traffic control devices such as stop bars, stop signs, double yellow lane separators striping, directional arrows and "Do Not Enter" signage, etc. See City Standard Drawings "K" Series for striping details. 2. Current standards require 9~-ft. x 18~-ft. parking stalls with a minimum 25-ft. backup distance for 900 parking. Some reduction in backup distance is allowed for angled parking. See City Standard Detail K-1 for dimensions. Revise parking layout accordingly. ENGINEERING 3. Add a general note to the Site Plan that all plans submitted for specific permits shall meet the City's Code requirements at time of application. These permits include, but are not limited to, the following: paving, drainage, curbing, site lighting, landscaping and irrigation. Permits required from other permitting agencies such as Florida Department of Transportation (FOOT), South Florida Water Management District (SFWMD), Lake Worth Drainage District (LWDD), Florida Department of Environmental Protection (FDEP), Palm Beach County Health Department (PBCHD), Palm Beach County Engineering Department (PBCED), Palm Beach County Department of Environmental Resource Management (PBCDERM) and any others, shall be included with the permit request. 4. All comments requiring changes and/or corrections to the plans shall be reflected on all appropriate sheets. 5. Please note that changes or reVISions to these plans may generate additional comments. Acceptance of these plans during the modification process does not ensure that additional comments may not be generated at permit review. . Department of Public Works/Engineering Division Memo No. 05-060 Re: EI Rosal Kingdom Hall of Jehovah's Witnesses, Miner Site Plan Modification - 1st Review May 17, 2005 Page 2 6. Provide written and graphic scales on all sheets. 7. Provide a Photometric plan. The lighting design shall provide a minimum average light level of one foot-candle. Include pole wind loading, and pole details in conformance with the LOR, Chapter 6, Article IV, Section 11, Chapter 23, Article I, Section 5.B.7 and Chapter 23, Article II, Section A on the Lighting Plan. Lighting shall be directed away from any residential uses (LOR, Chapter 2, Section 4.N.7.) 8. Show sight triangles on the Landscape plans (LOR, Chapter 7.5, Article II, Section 5.H.). Reference Palm Beach County Standards for the sight triangles on Seacrest Blvd. 9. Indicate, by note on the Landscape Plan, that within the sight triangles there shall be an unobstructed cross-visibility at a level between 2.5' and 8' above the pavement (LOR, Chapter 7.5, Article II, Section 5.H.). 10. Provide an engineer's certification on the Drainage Plan as specified in LOR, Chapter 4, Section 7.F.2. 11. Full Drainage plans, including drainage calculations, in accordance with the LOR, Chapter 6, Article IV, Section 5 will be required at the time of permitting. The provided drainage calculations were briefly reviewed for general conformance with City of Boynton Beach standards. No obvious errors were noted and a full review will be done at the time of permit application. 12. Paving, Drainage and Site details will not be reviewed for construction acceptability at this time. All engineering construction details shall be in accordance with the applicable City of Boynton Beach Standard Drawings and the "Engineering Design Handbook and Construction Standards" and will be reviewed at the time of construction permit application. UTILITIES 13. The LOR, Chapter 6, Article IV, Section 16 requires that all points on each building will be within 200 feet of an existing or proposed fire hydrant. Please demonstrate that the plan meets this condition, by showing all hydrants. 14. Comprehensive Plan Policy 3.C.3.4. requires the conservation of potable water. As other sources are readily available City water shall not be allowed for irrigation. LUck Cc: Jeffrey R. Livergood, P.E., Director, Public Works (via e-mail) Peter V. Mazzella, Deputy Utility Director, Utilities H. David Kelley, Jr., P.E.I P.S.M., City Engineer, Public Works/Engineering (via e-mail) Glenda Hall, Maintenance Supervisor, Public Works/Forestry & Grounds Division Larry Quinn, Solid Waste Manager, Public Works/Solid Waste Kenneth Hall, Engineering Plans Analyst, Public Works/Engineering (via e-mail) File S:\Engineering\Kribs\EI Rosal Kindom Hall of Jehovah's Witnesses, Minor Site Plan Mod. 1st Rev..doc