AGENDA DOCUMENTS
CITY OF BOYNTON BEACH
AGENDA ITEM REQUEST FORM
Requested City Commission Date Final Form Must be Turned Requested City Commission Date Final Form Must be Turned
Meeting Dates in to City Clerk's Office Meeting Dates in to Citv Clerk's Office
~ December 5, 2006 November 20, 2006 (Noon.) D February 20, 2007 February 5, 2007 (Noon)
0 January 2, 2007 December 18,2006 (Noon) D March 6, 2007 February 20, 2007 (Noon)
0 January 16, 2007 January 2,2007 (Noon) D March 20, 2007 March 5, 2007 (Noon)
0 February 6, 2007 January 16, 2007 (Noon) D April 3,2007 March 19,2007 (Noon)
D Announcements/Presentations D City Manager's Report
NATURE OF D Administrative D New Business
AGENDA ITEM D Consent Agenda D Legal
D Code Compliance & Legal Settlements D Unfmished Business
[8] Public Hearing D
RECOMMENDATION: Please place this request on the December 5,2006 City Conunission Agenda under
Public Hearing. The Community Redevelopment Agency Board on November 14,2006 recommended that this request be
approved. For further details pertaining to the request, see attached Department Memorandum No. 06-195,
EXPLANATION:
PROJECT:
AGENT:
OWNERS:
LOCATION:
DESCRIPTION:
Denmar Building (NWSP 06-024)
George Brewer, Brewer Architecture, Inc.
Mary Ann Monnin
615 NE 3rd Street
Request for a new site plan approval to construct a 3,433 square foot commercial retail
and contractor office/warehouse building and related site improvements on 0.34 acre in
the C-4 (General Commercial) zoning district.
PROGRAM IMPACT: N/A
FISCAL IMP ACT: N/ A
ALTERNATIVES: N/A
~Ubn~ ~
Development Departme rrector
City Manager's Signature
Assistant to City Manager
'fvu ~
PI " d'Z~ C' A /F'
annmg an onmg rrector tty ttomey mance
S:\Planning\SHARED\WP\PROJECTS\Denmar Bldg (fka Boynton Retail)\NWSP 06-024\Agenda Item Request Denmar Bldg NWSP 06-024 12-5-06,doc
S:\BULLETIN\FORMS\AGENDA ITEM REQUEST FORM.DOC
DEVELOPMENT DEPARTMENT
PLANNING AND ZONING DIVISION
MEMORANDUM NO. PZ 06-195
STAFF REPORT
TO:
Chair and Members of the Community Redevelopment Agency Board
and City Commission
Michael Rump~
Planning and Zoning Director
THRU:
FROM:
Kathleen Zeitler t~
Planner
DATE:
November 7, 2006
PROJECT NAME/NO:
Denmar Building / NWSP 06-024
REQUEST:
New Site Plan
PROJECT DESCRIPTION
Property Owner:
Mary Ann Monnin
Agent/ Applicant:
George Brewer of Brewer Architecture, Inc. / Mary Ann Monnin
Location:
617 NE 3rd Street (see Exhibit "A" - Location Map)
Existing Land Use/Zoning:
General Commercial (GC) / General Commercial (C-4)
Proposed Land Use/Zoning:
No change
Proposed Use:
Request new site plan approval to construct a 3,433 square foot
building for retail showrooms, contractor offices, and indoor storage
Acreage:
0.34-acre (14,975 square feet)
Adjacent Uses:
North:
Two developed commercial parcels (Paper Roll Products) classified General
Commercial (GC) and zoned General Commercial (C-4);
South:
A developed 7,500 square foot parcel classified General Commercial (GC) and
zoned General Commercial (C-4) with a residence;
Right-of-way for NE 3rd Street, and farther east a vacant 0.43-acre parcel classified
General Commercial (GC) and zoned General Commercial (C-4); and,
East:
West:
A vacant 8,302 square foot parcel classified General Commercial (GC) and zoned
General Commercial (C-4).
Staff Report - Denmar Building (NWSP 06-024)
Memorandum No PZ 06-195
Page 2
Site: According to the survey, the subject site consists of Lots 71 and 72 of Arden Park
which have been combined into a 0.34-acre parcel. The subject property is
described as a vacant, undeveloped commercial parcel. The survey indicates that a
portion of road right-of-way, which traversed in a southwesterly direction adjacent
to NE 3rd Street, was abandoned by the City pursuant to Ordinance No. 294 in
April, 1957 according to the plat of Arden Park (Plat Book 2, Page 96). In May,
2006 the Applicant petitioned the City to abandon a 10-foot wide unimproved alley
located adjacent to the north property line of the subject property (ABAN 06-006).
The alley was abandoned, conditioned upon the dedication of a 5-foot utility
easement. The current survey indicates a 5-foot wide utility easement runs in an
east-west direction along the north property line. This utility easement would not
be altered by the proposed development and would remain in its current state.
Proposal:
Concurrency:
Traffic:
School:
Police / Fire:
Utilities:
BACKGROUND
The Applicant is requesting new site plan approval for the construction of a one-
story 3,433 square foot commercial building (to include a retail showroom, and
contractor offices with indoor storage) on the 0.34-acre parcel. The interior of the
proposed building will be divided into four (4) business suites, each ranging from
810 to 1,000 square feet.
ANALYSIS
A traffic statement was sent to the Palm Beach County Traffic Division for
concurrency review in order to ensure an adequate level of service. In a response
dated August 14, 2006, Palm Beach County Traffic Division determined that the
project meets the Traffic Performance Standards. The project is estimated to
generate 161 new daily trips and has a build-out date of 2007.
School concurrency is not required for this type of project.
Staff reviewed the site plan and determined that current staffing levels would be
sufficient to meet the expected demand for services.
The City's water capacity, as increased through the purchase of up to 5 million
gallons of potable water per day from Palm Beach County Utilities, would meet the
projected potable water for this project. Local piping and infrastructure
improvements may be required, especially on the water delivery system for the
project, depending on the final project configuration and fire-flow demands. These
local improvements would be the responsibility of the site developer and would be
reviewed at the time of permitting. Sufficient sanitary sewer and wastewater
treatment capacity is also currently available to serve the project, subject to the
applicant making a firm reservation of capacity, following approval of the site plan.
Staff Report - Denmar Building (NWSP 06-024)
Memorandum No PZ 06-195
Page 3
Drainage:
Driveways:
Parking:
Landscaping:
Conceptual drainage information was provided for the City's review. The
Engineering Division has found the conceptual information to be adequate and is
recommending that the review of specific drainage solutions be deferred until time
of permit review (see Exhibit "C" - Conditions of Approval).
The site plan (sheet SP-1) shows one (1) point of access is proposed from NE 3rd
Street. The proposed driveway would be 25 feet in width and provide ingress and
egress.
According to the Land Development Regulations, parking space requirements shall
be computed separately for each principal use. Suites 1-2 are proposed as retail
use and would require one (1) parking space per 200 square feet, or eight (8)
spaces based on 1,620 square feet. Suites 3-4 are proposed as warehouse use for
contractors and would require one (1) parking space per 800 square feet, or four
(4) spaces based on 1,813 square feet. The site plan (Sheet SP-1) data indicates a
total of 12 parking spaces are required on site for the uses proposed. The site plan
depicts a total of 12 parking spaces, including one (1) space designated for
handicap use. A 12 foot by 35 foot loading space has also been provided at the
west end of the proposed building. All parking spaces, excluding the handicap
space and the loading zone, would be dimensioned nine (9) feet in width and 18
feet in length. All proposed parking stalls, including the size and location of the
handicap spaces were reviewed and approved by both the Engineering Division and
Building Division.
The entire parking lot, including the handicap space and loading zone is proposed
as brick pavers set in sand in a herringbone pattern. A walkway of brick pavers
would also be located along the sides and rear of the building, providing pedestrian
circulation as well as handicap accessibility. The use of brick pavers for all these
areas is understood to be the proposed contribution to the requirement for Art in
Public Places.
The proposed open space or "pervious" area would be 3,968 square feet, or 26.5%
of the total lot. The perimeter landscape buffer adjacent to the right-of-way of NE
3rd Street would be approximately seven (7) feet wide. The landscape plan (sheet
L-1) shows thatthis buffer would contain four (4) Purple Glory Trees, 12 to 14 feet
in height. These signature trees would require six (6) feet of clear trunk when
installed within the safe-sight triangle, as noted on the landscape plan. The right-
of-way landscape buffer would also contain a row of Redtip Cocoplum hedges and
Lilly Turf shrubs planted in groups. The western perimeter buffer would be two
and one-half (2 V2) feet in width and would include Live Oak shade trees and
clusters of Sabal palm trees with a row of Redtip Cocoplum hedges installed at the
base. The northern perimeter buffer is the same width and would contain the
same plant material as the western perimeter buffer. The southern perimeter
buffer would be two and one-half (2 V2) feet in width and would contain a row of
Redtip Cocoplum hedges.
Foundation landscaping around the building would include Lady Palms, Pinwheel
Jasmine, Cocoplum, and Lilly Turf. Enclosed areas for roll out carts, storage bins,
Staff Report - Denmar Building (NWSP 06-024)
Memorandum No PZ 06-195
Page 4
and recycle bins located at the southwest corner of the site would be screened by
landscaping through a combination of perimeter landscape buffers and landscape
islands within the parking lot. All landscaping on site would be irrigated with an
approved system connected to a non-potable water source. An existing five (5)
foot chain link fence along the north, west, and south property lines will remain.
Building and Site: The proposed building location on site complies with minimum setback
requirements (25 feet front, 20 feet rear, and 15 feet side) of the C-4 zoning
district. The proposed building is 3,433 square feet with a 23% lot coverage,
which complies with the maximum lot coverage (40%) allowed in the C-4 zoning
district. The proposed building has been designed as a one (l)-story structure. The
elevations (sheet A-3) show the top of the parapet wall at 20 feet in height, well
below the maximum of 45 feet allowed in the C-4 zoning district.
The building and site design as proposed would generally meet code requirements
when staff comments are incorporated into the permit drawings. The floor plan for
the building (sheet A-1) shows that the building would be divided into four (4)
separate interior spaces for tenants, with bay sizes ranging from 810 to 1,000
square feet in area. Suites 1 and 2 are proposed as retail uses and include large
storefront windows under a steel-framed awning. Suites 3 and 4 are proposed as
contractor warehouse storage and include garage doors under a steel-framed
awning. Each suite has a separate entry door in front and a separate rear door
which is handicap accessible. Windows in the rear of the building are glass block.
The exterior building design is compatible with the surrounding built environment in
compliance with the Community Design Plan guidelines. The building entrances
are enhanced by parapet roofs, large windows with fabric awnings, and these same
features are mirrored on the east side of the building near NE 3rd Street. Visual
interest has been added to the proposed building through the use of architectural
details such stucco walls, scoring lines, and a decorative parapet roof.
Building colors are neutral and include Sherwin William colors. According to the
exterior finish color schedule, the main body color of the building would be light
beige: "Ivoire" (SW 6127). The secondary wall color is proposed as a green:
"Alchemy" (SW 6395). The front and side elevations (south and east) are depicted
with canvas awnings over the doors and windows. These awnings are proposed as
a black and tan striped fabric material. The neutral color palette proposed will be
harmonious with surrounding developments.
Lighting:
The photometric plan (sheet LP-1) proposes freestanding lighting fixtures, as well
as wall mounted lighting fixtures. The freestanding pole fixtures would be 16 feet
in height and would be located at the access point and in the parking area. The
freestanding lights would be silver fiberglass poles designed for a windload of 140
miles per hour. The front and rear of the building would include decorative wall-
mounted lights near each door, as well as wallpacks for security lighting. All
proposed lighting will be shielded to direct light down and away from adjacent
properties and rights-of-way.
Staff Report - Denmar Building (NWSP 06-024)
Memorandum No PZ 06-195
Page 5
Signage:
No freestanding or wall signs are proposed at this time.
Art:
In compliance with the newly adopted requirement for developments to provide
public art work, the applicant proposes the art to be the entire parking lot. The
applicant is the owner of a brick paver business and proposes to design a parking
lot of pavers, in an interesting pattern with different paver types and colors. This
artwork will enhance the ambiance of the proposed development. Ultimate review
and approval of the artist and artwork is still pending by the Arts Commission.
RECOMMENDATION:
The Technical Advisory Review Team (TART) has reviewed this request for new site plan approval and
recommends approval contingent upon satisfying all comments indicated in Exhibit "c" - Conditions of
Approval. Any additional conditions recommended by the Board or City Commission shall be documented
accordingly in the Conditions of Approval.
S:\Planning\Shared\Wp\Projects\NE 3n:1 S1\NWSP\Staff Report.doc
5
Exhi.,=t "A" - Denmar B,,~~ding
Location Map
R2 - Duplex-Residential
~
\l.I
130 65 0
r-\..,1JIIIIIIIl_
130
260
390 520
'Feet
r
N
w+,
s
t!~IS \-
I!!i I--~~
~Ii~ il -..
!@~~ i r!ffrl ~
~~i~ I fin J~ ~
i~~! r J;~
~I~e ~fJa
~d~l -. l!! II~~
H~I i;lli ~
~ !
!III(
riB
I e~ J ~
S ~
~
~~ ttb
i!i. ~ ~ I
i'zl1
n
I~I~
.II~
!!,~gill~a n!1u.
~-l~~~~ 1il~~~;;I'~
"'tl;t:<li! ill ~-"'12;::! r
~-< 8!i!ii ~nG Ii:
~~~2:~S lil.:-'~~~ tl
"",-l :;!l!io~" ~
!1;!:i;..r :I: rl;n"'l-l!" "
lU :J>~-l Old,!, ;;j
~~~;~: ~i~~! ~
<j!!i!i~h~ n o~
"'-< -l -l:Z:"
'" tl;tru~:I: illO r~
~~~~~~ ~d~:
-<gt;llil,,'" "',,:1: 0
.. ""r Cl
~Zld",,,,!:l o:J>~~!:l
:J: ",(0'1"0 .,,-t;u~
~lil-lO~"'I "-l~rl~
"'I-lilj:n~ j!!:i1i~:!l....
1:I:"':I:16 Xlll-l-l.:l
<"'~"'",~ tl;tO-l:I:~
:J><~"2::J> ","'10'"
~B~~:~ 2~~~!
:z:rznO", Bl6i...
f"1-'" -tt::1 c: s:;:"
",ificillilj" ~~nl=l16
~ "'14 r -< "':I:;::l
t:t~b~~~ .. !Ez<~
~CIJ-tV)~", ?WUPllI>c
ill~" '" !il!;ru"'"'I
!:1~~IiI~b ~-4f~-I
b!i~","'I :J>at:l~iIj
-f r-~C JIoCt
,,~Xl;l!:l ;;1~~
ru"'lf j!!: !"t:lfj",
~ J;;
:I: -<
I
;!~
I~~
r
o
-l
01
0>
5
-l
01
ID
EXHIBIT "8'
r
I ~
Ii
jlI
~
!;J
~
RN~
t~i~
"
(,j
.2'\0'2
~ I
~;a~
!Ii~
5
-l
"
....
5 ~
ID
-l ID
01
.... 5 &;
0
-l 1Il ~
:::i c 5 ..
c ~
:J> -l
;0 r
1'1 .... -I
~ ., "
~
-l "
0 ~
t..
....
>
Q
"'
1Il
:iijiji!
tillnlil
=1 ipn
IJ ~~ sl ~
;j l!i~ !
llli~l
! PI ~
~ d
~gNS=:5~~;~~!~:~:i~~l~~~~~~:~~~~~'~~~~i~~~~e ~
iUiI!P~~~l!j~~jUl,!!~'~ji ~
[ I frl' 1,1111111 fllUlfld
I - f Jf l~Jf
50' R/W
617 Nc- rt.
.t:.. JRD STREET
rn
-l
I
)>
<
fTl
EXHIBIT "E
--------
ID
Iii ~I "I 'I~I
II b I~I I;!il
~I I' ~ql
l;i!li~
II~
nj m~1 'l'~1 ;'J~l
I! lilj li!1 'b~
;, , r;. ~
~
.n 111111 I II . III~ ~
1'lInm I I'. 1,'lIhl' ~
II 111111 I 5"
III i 'ii II n iP I
.-. I !fll
. I '
i' I
. I
~ .
L iii f It ~ I DENMAR BUILDING r=l.'
~I I OFFICE I RETAllJ WAREHOUSE BUllDING I l'~i.$.
61 7 N.E. 3RD STREET III..
BOYNTONBEACH,FL 33435
.iiiiiiiiiiiiil
~ 1I,,"dl ., I'I"~I
~ lhllill "I . ~
~ .
I II' I If .. .
II I II 'II 1- .. ~ 0 @
~ ....
0 i ~
II en ~~
111111 tI1
tJ ;F 1'4
IIII WI IIlil 11/1 fJ !
i,l 0 @
11'1 "! ' I 131 0 ~
II II · · ; I . ~
m ~
II II .. . . . I S.. :((i+
I I II ~ It
i I j n i
J I I I ~
Ell @
II" I
I
(@@ ~ ~
....-= -<
t. c;
I @@Ki) (i.@. · I @
1111 111111 IIUII 111511:1 III
. .
I I I I nnp nil nnqn II i
It II "1111 11'111 "IIIPI II
r r n r r i
1111 nllll 11,111 HIIIPI II
.. ,. . .. ,. ,. .. ,. .. , - .. . ,. ,. .. ~ ~ ... .. .. . . II :
: . . . .. .. . . . . ::: ... ,. ,. . . . - .
. . . .
. . . .
I I I II I I iI
I II II II
I q II I! I
II I
.. It
III
r- .
t. @
~Cw-
III
lil
!OO.
-;:=
....
III
I
...
II
EXHIBIT "B
-~
I I
~ I
I .
l'
~ .J Ill, I DENMAR BUILDING rlC '-I
I OFFICE I RETAII.JW AREHOUSE BunnING I II'.,. ·
617 N.E. 3RD STREET II ii..
BOYNTON BEACH, Fl 33455
~
-<
I"@ll '4
I~:L l! ",.."
I'" LV J-, itl ,II
t P ~ 1 .~II
I ~ \" ~_/ I_II
, 1R1If; ~I
I' ~.. ~1!l
;~(~f Sl
~ J,\J@1 ~ .
ai ~ I.! JI
....10'-- Jr--
4' 0. tJ
jlo.@7
~II ~
@ ~~
J7 !~' ~ lj1
4. >~
I IT-, I~
r~- rrt
'\. .. LII 'I:I' [!]
~jSJr~!!'
f@l f@\n 'Jm
,J n----, 4. U1i I
.~
@ ~
~
~
lJ
l..- ~.
-=vi
bC
8;;:l
~~
-'---
~V>
-C
~;;:l
:nw
~
o
'II
Q
i ~Vl
-< o~
Y';;:J
:n""
5
il-
0.@J
It
~o~ }II
~m rv-. I
.- \!I J
:'\ 'i
rf' ..~
J7~
I:i\
~ 0.J7
~ 5-
II ~
T .
~ V@I
,.....'l -:--
I ,Po \ nl
~,l r~i nU
I~--~l U
I @l I @ll/
'l'
!
III I
~
EXHIBIT liB
In ~I
Ui 'I
-I ~I
~z ~CI'.l I I
roO' ~O ~O
~t:r.1 ~:;:o ~e
~:> ~ ~ I ""'3
~CI'.l .0=
~ i: ~ t-- utI]
~t:r.1 ..~
u ~ I. t:r.1 I ~
..
.< , ~ I
:> ~ I ~ ~
I ~ 0 ~
0 Z
Z
K I
K
Ii
~s
a
I
I
I i
I
I
~~ 1 I
I
I i Ii
I
I
I
~CI'.l I ~ I ~I
I i
""'3 I
I ~ I U
I
~ I I I
I I Ii ~
.. t:r.1 , II ~
~ ~ , "
~
~ or
0 J
Z ~I !
II I
I b ~ ~
~ I Q ( ! Q (I I
Q (I i I II
I I; .H I I I I 'I 4Ul
~ li ~ ~ ~ ~ 1 ~~~ ~ ~I
II I
~J
U~~ I DENMAR BUILDING ,.. C ,.,
I I OFFICE IRETAIIJW ARBHOUSE BUILDING I ilii .1$ ·
617 NE. 3RD SlREET
BOYNTON BEACH. FL 33455
J' ~
~~
tj
en
~
ts
~I
I
I
~~a....~i'
li2'iil"l~
. . ...I~
11111Ij'l!
IIIIII1
IS!qql
I' ~;I~I
I
-......Jill
;n:lHlo
.~f~~ll
Ii I I
~
!!IU
I'dl
i!li
~I~~
il:
EXHIBIT liB
III
Q~'
II
111~i i illi il'I!1 1111
!HI ,'I ! III ;JII
~ ~ III. ff' III' I!i
Ii . ~
o "
~~lli i it I 'I:
~ b'.~ · "1 i
I 'II' i 'I
1.1
.i I
lif
I"
I!
un..I~ I
IInel'
lIuf
"n
!II
j i
i ;
j
I
~Mid~U
lI~u~u
d Illl I DENMAR BUILDING rr.i-I
~ IOFFICE I REl'All./W ARBHOUSE BUILDING I niL: ·
617 N.E. 3RD STREET
BOYNTON BEACH. FL 33435
EXHIBr~ ~C" - CONDITIONS OF Al:tROV AL
New Site Plan
Project name: Denmar Building
File number: NWSP 06-024
Reference: 2nd review plans identified as a New Site Plan with an October 17,2006 Planning and Zoning
Department date stamp marking.
DEPARTMENTS INCLUDE REJECT
PUBLIC WORKS -Solid Waste
Comments: None X
PUBLIC WORKS - Forestry & Grounds
Comments: None X
PUBLIC WORKS - Traffic
Comments: None X
UTILITIES
Comments:
1. All utility easements and utility lines shall be shown on the landscape plans X
so that we may determine which appurtenances, trees or shrubbery may
interfere with utilities. In general, palm trees will be the only tree species
allowed within utility easements. Canopy trees may be planted outside of the
easement so that roots and branches will not impact those utilities within the
easement in the foreseeable future. The LDR, Chapter 7.5, Article I, Section
18.1 gives public utilities the authority to remove any trees that interfere with
utility services, either in utility easements or public rights-of-way.
2. Fire flow calculations will be required demonstrating the City Code X
requirement of 1,500 g.p.m. (500 g.p.m. some residential developments) with
20 p.s.i. residual pressure as stated in the LDR, Chapter 6, Article IV, Section
16, or the requirement imposed by insurance underwriters, whichever is
greater (CODE, Section 26-16(b)).
3. The CODE, Section 26-34(E) requires that a capacity reservation fee be paid X
for this project either upon the request for the Department's signature on the
Health Department application forms or within seven (7) days of site plan
approval, whichever occurs first. This fee will be determined based upon
final meter size, or expected demand.
4. This office will not require surety for installation of the water and sewer X
utilities, on condition that the systems be fully completed, and given to the
City Utilities Department before the first permanent meter is set. Note that
setting of a permanent water meter is a prerequisite to obtaining the
Certificate of Occupancy.
CONDITIONS OF APPROVAL
DENMAR BUILDING
NWSP 06-024
PAGE 2
,
DEPARTMENTS INCLUDE REJECT
5. A building permit for this project shall not be issued until this Department has X
approved the plans for the water and/or sewer improvements required to
service this project, in accordance with the CODE, Section 26-15.
6. Utility construction details will not be reviewed for construction acceptability X
at this time. All utility construction details shall be in accordance with the
Utilities Department's "Utilities Engineering Design Handbook and
Construction Standards" manual (including any updates) and will be
reviewed at the time of construction permit application.
ENGINEERING DIVISION
Comments:
7. All comments requiring changes and/or corrections to the plans shall be X
reflected on all appropriate sheets.
8. Please note that changes or revisions to these plans may generate additional X
comments. Acceptance of these plans during the Technical Advisory Review
Team (TART) process does not ensure that additional comments may not be
generated by the Commission and at permit review.
9. Full drainage plans, including drainage calculations, in accordance with the X
LDR, Chapter 6, Article N, Section 5 will be required and reviewed at the
time of permitting.
10. Paving, drainage and site details will not be reviewed for construction X
acceptability at this time. All engineering construction details shall be in
accordance with the applicable City of Boynton Beach Standard Drawings
and the "Engineering Design Handbook and Construction Standards"
and will be reviewed at the time of construction permit application.
FIRE
Comments: None X
POLICE
Comments: None X
BUILDING DIVISION
Comments:
CONDITIONS OF APPROVAL
DENMAR BUILDING
NWSP 06-024
PAGE 3
DEPARTMENTS INCLUDE REJECT
11. Buildings, structures and parts thereof shall be designed to withstand the X
minimum wind loads of 140 mph. Wind forces on every building or structure
shall be determined by the provisions of ASCE 7, Chapter 6, and the
provisions of 2004 FBC, Section 1609 (Wind Loads). Calculations that are
signed and sealed by a design professional registered in the state of Florida
shall be submitted for review at the time of permit application.
12. At time of permit review, submit signed and sealed working drawings of the X
proposed construction.
13. Add to the building that is depicted on the drawing titled site plan and floor X
plan a labeled symbol that identifies the location of the handicap-accessible
entrance doors to each tenant space. 2004 FBC, Sections 11-4.1.2, 11-4.1.3,
and 11-4.3.
14. Identify within the site data the finish floor elevation (lowest floor elevation) X
that is proposed for the building. Verify that the proposed elevation is in
compliance with regulations of the code by adding specifications to the site
data that address the following issues:
. The design professional-of-record for the project shall add the following text
to the site data. "The proposed finish floor elevation _' _ NGVD is
above the highest 100-year base flood elevation applicable to the building
site, as determined by the SFWMD' s surface water management construction
development regulations."
. From the FIRM map, identify in the site data the title of the flood zone that
the building is located within. Where applicable, specify the base flood
elevation. If there is no base flood elevation, indicate that on the plans.
15. Add to the submittal a partial elevation view drawing of the proposed X
perimeter fence. Identify the type of fence material and the type of material
that supports the fence, including the typical distance between supports. Also,
provide a typical section view drawing of the fence that includes the depth
that the fence supports are below finish grade and the height that the fence is
above finish grade. The location and height of the fence shall comply with the
fence regulations specified in the Zoning Code.
16. CBBCPP 3.C.3.4 requires the conservation of potable water. City water may X
not, therefore, be used for landscape irrigation where other sources are readily
available.
17. A water-use permit from SFWMD is required for an irrigation system that X
utilizes water from a well or body of water as its source. A copy of the permit
shall be submitted at the time of permit application, F.S. 373.216.
18. If capital facility fees (water and sewer) are paid in advance to the City of X
Boynton Beach Utilities Department, the following information shall be
provided at the time of building permit application:
CONDITIONS OF APPROVAL
DENMAR BUILDING
NWSP 06-024
PAGE 4
DEPARTMENTS INCLUDE REJECT
. The full name of the project as it appears on the Development Order and the
Commission-approved site plan.
. The total amount paid and itemized into how much is for water and how
much is for sewer.
(CBBCO, Chapter 26, Article II, Sections 26-34)
19. At time of permit review, submit separate surveys of each lot, parcel, or tract. X
For purposes of setting up property and ownership in the City computer,
provide a copy of the recorded deed for each lot, parcel, or tract. The recorded
deed shall be submitted at time of permit review.
20. Pursuant to approval by the City Commission and all other outside agencies, X
the plans for this project must be submitted to the Building Division for
review at the time of permit application submittal. The plans must incorporate
all the conditions of approval as listed in the development order and approved
by the City Commission.
21. The full address of the project shall be submitted with the construction X
documents at the time of permit application submittal. The addressing plan
shall be approved by the United States Post Office, the City of Boynton
Beach Fire Department, the City's GIS Division, and the Palm Beach County
Emergency 911.
. Palm Beach County Planning, Zoning & Building Division, 100 Australian
Avenue, West Palm Beach, Florida (Sean McDonald - 561-233-5013)
. United States Post Office, Boynton Beach (Michelle Bullard - 561-734-0872)
22. Drinking fountains are required in each bay per the 2004 FBC, Plumbing, X
Table 403.1. Drinking fountains shall be handicap accessible.
23. This is a mixed occupancy building. Occupancy separation shall be required X
per 2004 FBC, Table 302.3.2, Footnote #B.
PARKS AND RECREATION
Comments: None X
FORESTER/ENVIRONMENT ALIST
Comments: None X
PLANNING AND ZONING
Comments:
CONDITIONS OF APPROVAL
DENMAR BUILDING
NWSP 06-024
PAGE 5
DEPARTMENTS INCLUDE REJECT
24. Revise building elevations to include colors and materials proposed for X
building walls, trim, roof, awnmgs, garage doors, etc. with paint
manufacturer, name color of paint and paint code (i.e. Sherwin Williams
"Ivoire SW 6127") .
COMMUNITY REDEVELOPMENT AGENCY STAFF COMMENTS
Comments: None X
ADDITIONAL COMMUNITY REDEVELOPMENT AGENCY BOARD
COMMENTS
Comments:
None X
ADDITIONAL CITY COMMISSION COMMENTS
Comments:
To be determined.
MWRIkz
S:IPlanningISHARED\WPIPROJECTSINE 3rd Street INWSP 06-024ICOA.doc
--. ...-.-".-'. .--....
To the City Clerk - City 0/ Boynton Beach
AFFIDA.VIT
_ J h 7 /I J j L... /J ~J. .6c.J'1~rJ
RE: Property Address: (;? IS r-r;.......;) //T~ '7
Project Name: ~.A_.)/n CIA /ICi~
l/We, the rmdersigned do crih that to the bestofmy knowledge, the
. attached .ownenhip list, 400' .radill9 tnIIp and mailing labels area complete
IJIId accurute representation of the real estate property and property
owners within at least 400 feet of the above-referenced subject property.
This reflec'ls the most current records on file in the Palm Beach County
Property Appraiser.'s Office.
The notifications were postmarked a minimum 0110 days;n advance of
the public hearing.
Site signs were posted on tbe premises 10 days in advance of the public
hearing in. accordlJnce with City OrdilllJnce 04-007. A.ttlJched fire
photogrllp'hs of the signs showing their placement on the property.
)
ci/k; t2 At'.
Cc: Plamling & Zoning Department
ulb~b
~'!';ely, . 21..
".)1~ a ~ .
~/Agent
Nofary Public, State of Florida
S:\PIarm1ngiPftumitlf TMtpla1mP&Z lent" tmd 1tf/!"."IAFFJDA. JllT.tItJc
~~.