Loading...
APPLICATION City Codes Accessed Via Website www.bovnton-heach..cY-IT. \>iww,amlcgaLc.om/bovnton beach J1 CITY OF BOYNTON BEACH, FLORIDA PLANNING & ZONING DIVISION SITE PLAN REVIEW APPLICATION FOR NEW SITE PLANS & MAJOR MODIFICATIONS TO EXISTING SITE PLAN Has applicant attended a pre-application meeting? Date This application must be filled out completely, accurately and submitted as an original to the Planning and Zoning Division. TWELVE COMPLETE, sequentially numbered, ASSEMBLED AND STAPLED sets of plans including a recent survey and appropriate fee shall be submitted with the application for the initial process of the Site Plan Review procedure. AN INCOMPLETE SUBMITTAL WILL NOT BE PROCESSED. Please print legibly (in ink) or type all information. I. GENERAL INFORMATION 1. Project Name: Parks ide 2. Property Owner's (or Trustee's) Name: see attached Address: (Zip Code) Phone: Fax: 3. Applicant's name (person or business entity in whose name this application is made): EastCoast Communities, Inc. Address: 6499 N. Powerline Road, 11101, Fort Lauderdale, FL 33309 (Zip Code) Phone: (954) 680-1544 Fax: (954) 680-4862 If contract purchaser, please attach contract for sale and purchase. 4. Agent's Name (person, if any, representing applicant): Ruden McClosky Address: 222 Lakeview Avenue 11800, West Palm Beach, FL 33401 (Zip Code) Phone: (561) 838-4542 Fax: (561) 514-3442 5. Correspondence to be mailed to agent only; if no agent, then to applicant unless a substitute is specified below:* *This is the one address to which all agendas; letters and other materials will be mailed. 6. What is applicant's interest in the premises affected? (owner, buyer, lessee, builder, developer, contract purchaser, etc,) contract purchaser ALL OWNERS Owner Boynton Townhomes, LLC KCB Enterprises, LLC Judy J, Lange Estelle B, Killian George E, Ford & Estate of Grace K. Ford Boynton Townhomes, LLC Boynton Townhomes, LLC Boynton Townhomes, LLC Estelle B, Killian Street Address 106 Miller Road 108 Miller Road 110 Miller Road 117 Miller Road 115 Miller Road N, Federal Highway 3506 N, Federal Highway 3480 Old Dixie Hwy 3508 N, Federal Hwy PARKSIDE LEGAL DESCRIPTIONS/STREET ADDRESSES Legal Description KILLlANS PARK Lot 6 and West 1/2 of Lot 7 KILLlANS PARK E 1/2 of L T 7 & L T 8 KILLlANS PARK L T 9 & W 1/2 of L T 10 KILLlANS PARK LT 16 & E 1/2 ofLT 17 KILLlANS PARK E 1/2 ofLT 10 & L T 11 KILLlANS PARK W 1/2 OF L T 17, L T 18 & E 1/2 OF L T 19 KILLlANS PARK E 1/2 OF L T 13 & L T 14 KILLlANS PARK LT 12 & W 1/2 LT 13 KILLlANS PARK L T 15 AMND PL OF TRADE WIND ESTATES L T 59 AMND PL OF TRADE WIND ESTATES L T 37 AMND PL OF TRADE WIND ESTATES LT 38 & LT 58/LESS RD R1W/ KILLlANS PARK L TS 21 TO 29 INC KILLlANS PARK W 1/2 OF LT 19 & LT 20 PCN 00-43-46-04-11'{)00'{)060 00-43-46.{)4-11.{)00.{)071 00-43-46.{)4-11.{)00.{)090 00-43-46-04-11'{)00'{) 160 00-43-46-04-11'{)00'{) 1 0 1 00-43-46'{)4-11'{)00'{) 171 00-43-46'{)4-11'{)00'{) 131 00-43-46'{)4-11'{)00'{) 120 00-43-46-04-11'{)OO'{) 150 00-43-46-04-17 .{)00.{)590 08-43-46-04-17 .{)00.{)370 08-43-46-04-17 .{)00.{)380 00-43-46-04-11'{)00'{)210 00-43-46-04-11'{)00'{) 191 LEGAL DESCRIPTION That part of Lot 59, "Amended Plat of Trade Winds Estates, a Subdivision," according to the Plat thereof, recorded in Plat Book 21, Page 73, of the Public Records of Palm Beach County, Florida; lying west of the right-of-way of State Road 5 (U.S. Highway No.1) as conveyed to Palm Beach County, Florida, by a deed recorded in Official Records Book 124, Page 638 of the Public Records of Palm Beach County, Florida. Together with: Lots 37, 38 and 58 of "Amended Plat of Trade Winds Estates," according to the Plat recorded in Plat Book 21, Page 73, of the Public Records of Palm Beach County, Florida, less that portion deeded to the State of Florida by instrument in Official Records Book 104, page 35. Together with: Lot 15, "Killian's Park, a Subdivision," according to the Plat thereof, as recorded in Plat Book 23, Page 195, in the Public Records of Palm Beach County, Florida, less that portion of Lot 15 conveyed to the State of Florida by a Warranty Deed recorded in Official Records Book 119, Page 453, of the Public Records of Palm Beach County, Florida. Together with: All of Lots 6 through 14 and Lots 16 through 29 of "Killian's Park" recorded in Plat Book 23, Page 195, in the Public Records of Palm Beach County, Florida. Together with: The 30-foot right-of-way of Miller Road as shown on the Plat of "Killian's Park" recorded in Plat Book 23, Page 195, in the Public Records of Palm Beach County, Florida, adjoining Lots 6 thru 14 of said "Killian's Park." Said lands containing 7.402 acres, more or less. WPB:214125:1 7. Street address of location of site: 106-117 Miller Road, 3506-3508 N. Federal Highway, 3480 Old Dixie Highway 8. Property Control #(PCN) see attached 9. Legal description of site: see attached 10. Intended use(s) of site: multifamily residential (townhome) redevelopment pro;ect 11. Architect: Virtual Design Group / Friese Design Group 12. Landscape Architect: George Keen 13. Site Planner: Virtual Design Group / Friese Design Group 14. Engineer: Winningham & Fradley 15. Surveyor: Absolute Surveying 16. Traffic Engineer: TrafTech 17. Has a site plan been previously approved by the City Commission for this property? No II. SITE PLAN The following information must be filled out below and must appear, where applicable, on all copies of the site plan. 1. Land Use Category shown in the Comprehensive Plan: Special High Density Residential 2. Zoning District: PUD 3. Area of Site 7.402 acres .322,430 sq, ft, 4. Land Use -- Acreage Breakdown: a. Residential, including ? ')? acres 34,05 % of site surrounding lot area of grounds b. Recreation Areas * 0.280 acres 3.79 % of site (excluding water area) Water Area 0 0 % of site c. acres d. Commercial 0 acres 0 % of site e. Industrial 0 acres 0 % of site f. Publicll nstitutional 0 acres 0 % of site g. Public, Private and Canal rights-of-way 0 acres 0 % of site h. Other (specify) acres % of site i. Other (specify) acres % of site j. Total area of site 7 4~re acres 1 OO~ % of site *including open space suita e for outdoor recreation, and aving a minimum dimension of 50 ft. by 50 ft. 5. Surface Cover a. b. c. courts. site d. e. Ground floor building area ("building footprint") 2.52 34.05 % of site acres Water area o % of site acres o Other impervious areas, including paved area of public & private streets, paved area of parking lots & driveways (excluding landscaped areas), and sidewalks, patios, decks, and athletic o , 356 acres 4 . 8 ] % of Total impervious area 5.156 acres 69.66 % of site Landscaped area O. 277 acres 3 . 74 % of site inside of parking lots (20 sq.ft. per interior parking space required - see Sec. 7.5-35(g) of Landscape Code). f. Other landscaped areas, 1 .811 % of site acres 24.46 g. Other pervious areas, including golf course, natural areas, yards, and swales, but excluding water areasO .16 acres? 11 % of site h. Total pervious areas 2.248 acres 10 33 % of site i. Total area of site 7.402 100 % of site acres 6. Floor Area a. Residential 282.618 sq. ft. b. Commercial/Office 0 sq. ft. c. Industrial/Warehouse 0 sq. ft. d. Recreational 3490 sq. ft, e. Publicll nstitutional sq. ft. f. Other (specify) sq. ft. g. h. Other (specify) sq, ft, Total floor area 282.618 sq. ft. 7. Number of Residential Dwellinq Units a. Single-family detached 0 sq, ft, b. Duplex 0 sq. ft, c. Multi-Family (3 + attached dwelling units) (1) Efficiency 0 dwelling units (2) 1 Bedroom 62 dwelling units (3) 2 Bedroom 59 dwelling units (4) 3+ Bedroom 0 dwelling units d. Total multi-family 121 dwelling units e. Total number of dwelling units 1 ? 1 8. Gross Density 161') dwelling units per acre 9. Maximum height of structures on site 42 feet 1 stories 10. Required off-street oarkinq a. Calculation of required # of off-street parking spaces. Off-street parking spaces provided on site plan res. units rec. bldg 121 x 2 = 23 required = 242 27 %9 = b, Calculation of required # of handicap parking spaces 1 per 7c) 1 ~pRC.~ rpqllired = Number of handicap spaces provided on site plan 1 pr()~d rI ",r1 REPRESENTATIVE OF THE PROJECT MUST BE PRESENT AT ALL TECHNICAL REVIEW COMMITTEE, PLANNING AND DEVELOPMENT BOARD OR COMMUNITY REDEVELOPMENT AGENCY (CRA) AND CITY COMMISSION MEETINGS HELD TO REVIEW THIS PROJECT. III. CERTIFICATION (I) (We) understand that this application and all papers and plans submitted herewith become a part of the permanent records of the Planning and Zoning Division (I) 0Ne) hereby certify that the above statements and any statements or showings in any papers or plans submitted herewith are true ) (our) owledge and belief. This application will not be accepted ess signed a e i tructions below. IV. AUTHORIZATION OF AGENT Ruden McClosky By: Signature of Authorized Agent q:~-as Date ~-X) -DS Date ned person as (my) (our) authorized agent in regard to Date j- de- as Date - dO-ClS Date A REPRESENTATIVE MUST BE PRESENT AT ALL TECHNICAL REVIEW COMMITTEE, PLANNING AND DEVELOPMENT BOARD OR COMMUNITY REDEVELOPMENT AGENCY (CRA) AND CITY COMMISSION MEETINGS HELD TO REVIEW THIS PROJECT, RIDER TO SITE PLAN APPLICATION The undersigned as applicant for Final Site Plan Approval does hereby acknowledge, represent and agree that all plans, specifications, drawings, engineering, and other data submitted with this application for review by the City of Boynton Beach shall be reviewed by the various boards, commissions, staff personnel and other parties designated, appointed or employed by the City of Boynton Beach, and any such party reviewing the same shall rely upon the accuracy thereof, and any change in any item submitted shall be deemed material and substantial, The undersigned hereby agrees that all plans, specifications, drawings, engineering and other data which may be approved by the City of Boynton Beach, or its boards, commissions, staff or designees shall be constructed in strict compliance with the form in which they are approved, and any change to the same shall be deemed material and shall place the applicant in violation of this application and all approvals and permits which may be granted. The applicant agrees to allow the City of Boynton Beach all rights and remedies as provided for by the applicable codes and ordinances of the City of Boynton Beach to bring any violation into compliance, and the applicant shall indemnify, reimburse and save the City of Boynton Beach harmless from any cost, expense, claim, liability or any action which may arise due to their enforcement of the sa vi RJEAY. ACK~WLEDGED AND AGREED TO this do a of ~ ~-- ~' It ('{: 7 JJet-2>,J Applican EastCoast Communities, Inc. ---- I S ~ ~"'^- S ~.s"-.~~~ , 20oS" CONCURRENCY REQUIREMENTS NOTICE TO APPLICANTS FOR APPROVAL OF LAND DEVELOPMENT ORDERS OR PERMITS Please be advised that all applications for the following land development orders and permits which are submitted on or after June 1, 1990 will be subject to the City's Concurrency Management Ordinance, and cannot be approved unless public facilities (potable water, sanitary sewer, drainage, solid waste, recreation, park, and road facilities) would be available to serve the project, consistent with the levels of service which are adopted in the City's Comprehensive Plan: Building permit applications for the construction of improvements, which, in and by themselves, would create demand for public facilities. Applications for site plan approval. Applications for conditional use approval. Applications for subdivision master plan approval. Applications for preliminary plat approval. Applications for final plat approval. Applications for rezoning to planned zoning districts. Applications for revisions to any of the applications listed above, which would increase the demand for any public facility. Any other application, which, in and by itself, would establish the density or intensity of use of land, or a maximum density or intensity of use of land. Applications for development orders and permits submitted after February 1, 1990 and which generate more than 500 net vehicle trips per day, must comply with the Palm Beach County Traffic Performance Standards Ordinance, unless exempt from that ordinance. Please be advised, however, that the following applications will be exempt from the Concurrency Management Ordinance, pending final approval of this ordinance by the City Commission: Applications for the development of property which was platted on or after January 13, 1978 and either the final plat or the preliminary plat and Palm Beach County Health Department permit applications were submitted or approved prior to June 1, 1990, and the use of the property is consistent with the general use which was intended for the property at the time of platting. Applications for the development of property, which was platted prior to January 13, 1978, the area of the platted lots does not exceed 2 acres, and the proposed use would not generate more than 500 net vehicle trips per day. Applications for building permit, if a site plan or conditional use application was submitted prior to June 1, 1990 and subsequently approved and the site plan or conditional use has not expired. Applications for the development of property within an approved Development of Regional Impact, and which are consistent with the approved DRI. Applications for approval of final plats, if the preliminary plat and application for Palm Beach county Health Department permits for utilities have been submitted prior to June 1, 1990. Applications for revisions to previously approved development orders or permits, which do not increase the demand for any public facility. Please be advised that these exemption rules are tentative and will be subject to final approval by the City Commission, If you have any questions concerning the proposed Boynton Beach Concurrency Management Ordinance, please contact the Boynton Beach Planning &Zoning Division at (561) 742-6260. CHAPTER 4 SITE PLAN REVIEW Section 7. Submission Requirements. Each applicant shall submit to the Planning and Zoning Division the following plans and exhibits in the number of copies specified by the Planning and Zoning Division, together with a Site Plan Review application and a fee adopted by resolution by the City Commission, 12 ASSEMBLED COPIES REQUIRED A. ExistinQ site characteristics map: A sealed survey, not older than six months, showing all adjacent streets, alleys and driveways, and also illustrating: 1. Existing natural features, including but not limited to lakes, trees and other vegetation and soils and topography. 2. Existing buildings, building elevations, other structures, including use, height, dimensions and setbacks. 3. Existing utility lines and all easements, 4. Existing elevations (corner, street and finished floor) B. Site development plan: 1. A scaled drawing clearly illustrating proposed buildings and other structures, and any existing buildings and structures, which are to be retained, including use, height, dimensions and setbacks. 2. Proposed off-street parking spaces, driveways and sidewalks, including location, dimensions and setbacks, traffic control markings and signage. 3. Proposed fences and walls, including location, dimensions, setbacks, height and material. 4. Proposed location of lighting on site. 5. Proposed dumpster location. C. Landscape plan: 1. A separate scaled drawing (at the same scale as the site development plan) prepared as required by state law clearly illustrating proposed trees, shrubs, grass and 2. Proposed berms, watercourses and other topographic features. 3. A notation on method of irrigation. Architectural plan: 1. A scaled drawing clearly illustrating proposed building floor plan and elevations, including height, exterior dimensions, exterior color and materials. 2. A colored elevation drawing (not mounted) showing all elevations of the building. (This submittal can be waived by the Planning and Zoning Director when not applicable.) E. Tabular Summary ContaininQ: 1. Total gross project area by acreage and square footage and net buildable land area in acres and square feet. 2. Total number of proposed residential units, including characteristics by number of bedrooms and bathrooms and gross square footage of each typical unit. 3. Proposed nonresidential floor type of use and total gross square footage. 4. Square footage and percentage distribution of the total project site, including areas proposed for landscaped open space, vehicular use areas, other paved areas, and building coverage and total coverage. 5. Number and ratio of required and provided off-street parking spaces and number of loading spaces. 6. Water bodies in acres and square feet. 7. Height of buildings. F. DrainaQe plan: 1. 2. A separate scaled drawing (at the same scale as the site development plan) showing elevations, flow arrows, proposed drainage structures, proposed treatment facilities, etc. An engineer's certification in writing that drainage will conform with all rules, regulations, codes, etc. including, but not limited to, Chapter 6, Article IV, Section 5 of these Land Development Regulations. Revised 10/26/01 ~ Ruden ~~I McClosky 222 LAKEVIEW AVENUE SUITE 800 WEST PALM BEACH, FLORIDA 33401-6112 (561) 838-4542 FAX, (561) 514-3442 KIM GLASCASTRO@RUDEN,COM 9/20/2005 Parkside Annexation, Comprehensive Plan Amendment, Rezoning and Abandonment Annexation EastCoast Communities, Inc. (the "Applicant") is requesting voluntary annexation of 4.456 acres, located along the City's southern boundaries, between Federal Highway and Old Dixie Highway. This annexation area includes twelve (12) parcels and Miller Road!. Of these 12 parcels, 6 are vacant, 4 are improved and occupied single-family residences, and 1 is improved with a commercial building. The subject area is under contract for purchase by the Applicant, and is proposed for assembly with adjacent properties within the City limits to facilitate a redevelopment project. Comprehensive Plan Amendment (Land Use Change) The Applicant is requesting an amendment to the Boynton Beach Comprehensive Plan to amend the land use on a total of 7.402 acres. This area includes the aforementioned annexation area (4.456 acres), which will be changed from Palm Beach County land use designations of Commercial High/5 and Medium Residential 5 (5 dulac), as well as 2.946 acres currently within the City limits that is designated with the City land use designations of General Commercial and Local Retail Commercial. The City's Special High Density Residential (up to 20 dulac) is requested. The proposed land use change will facilitate the redevelopment of the area with a townhome community, Parkside. Rezoning Concurrent with the voluntary annexation and small-scale land use amendment, the Applicant is requesting rezoning of the subject property from the current C3, C4, RM and CG (latter two are County zoning) districts to Infill Planned Unit Development (IPUD). The proposed Parkside residential community is comprised of 121 townhomes for a gross density of 16.35 dulac, which is consistent with the Special High Density Residential land use designation. ! Miller Road was dedicated to the "public" via the Killian's Park Plat (PB23, PgI95), and upon annexation of the area becomes a city road, per Palm Beach County Land Development Division - Engineering Department. WPB:214174:1 RUDEN, McCLOSKY, SMITH, SCHUSTER & RUSSELL, P.A. CARACAS · FT, LAU DERDALE · MIAMI · NAPLES · PORT ST, LUCIE · SARASOTA. ST, PETERSBURG . TALLAHASSEE . TAMPA · WEST PALM BEACH Page 2 Consistent with the criteria contained in Section 9.C.2. of the Zoning regulations, the Applicant offers the following for the City's consideration: a. Whether the proposed rezoning would be consistent with applicable comprehensive plan policies. The proposed rezoning to IPUD is consistent with the proposed land use designation of Special High Density Residential (being concurrently processed). Rezoning to IPUD will allow redevelopment of the property, which is currently underutilized due to the antiquated subdivision pattern, with a viable new residential community. b. Whether the proposed rezoning would be contrary to the established land use pattern, or would create an isolated district unrelated to adjacent and nearby districts, or would constitute a grant of special privilege to an individual property owner as contrasted with the protection of the public welfare. Rezoning to IPUD will promote efficient use of the subject property. The subject property's location within the City's redevelopment area, and within Planning Area V of the Federal Highway Corridor Community Redevelopment Plan suggest that the requested intensity is appropriate for the area. The immediate area can be characterized as high density residential and commercial to the north and east, and single-family, moderate density to the west, across Old Dixie Highway and the FEC Railroad tracks. The Property has double frontage, Federal Highway on the east and Old Dixie Highway on the west. The land use amendment and rezoning will redesignate the Property with a single land use/zoning, thereby preventing underutilization of the site or the proliferation of strip commercial. The Property to the south is not located within the City limits. The immediate area has seen redevelopment interest in recent years and the conversion of strip commercial uses to multi-family residential. The Special High Density Residential and IPUD designations are consistent with the transition in uses that are recommended in the Federal Highway Corridor Community Redevelopment Plan. Parkside represents the logical progression of uses, which are less intense than that of the central business district, but greater than surrounding areas. c. Whether changed or changing conditions make the proposed rezoning desirable. The subject property is currently improved with four residences, a commercial structure, but half of the area is vacant. Redevelopment of the property is desired, as evidenced by its location within the City's Community Redevelopment Area. The proposed rezoning maintains the residential character of the area, and will provide an aesthetic living environment in proximity to the downtown. d. Whether the proposed rezoning would be compatible with utility systems, roadways, and other public facilities. The proposed rezoning and resulting townhouse residential neighborhood will not negatively impact public facilities and services. The proposed WPB:214174:1 RUDEN, McCLOSKY, SMITH, SCHUSTER & RUSSELL, P.A. CARACAS' FT, LAUDERDALE. MIAMI. NAPLES. PORT 5T, LUCIE' SARASOTA. ST, PETERSBURG . TALLAHASSEE . TAMPA. WEST PALM BEACH Page 3 development will meet the adopted level of service standards established pursuant to the City's concurrency management system. The Property is located within the residential exception area and is not subject to countywide traffic performance standards. The proposal does not negatively impact the surrounding roadway network. e. Whether the proposed rezoning would be compatible with the current and future use of adjacent and nearby properties, or would affect the property values of adjacent and nearby properties. The proposed rezoning to IPUD is compatible with adjacent uses: County RM and City IPUD to the south, RIA to the west across the rail line, County RM and CG, as well as City IPUD and C4 to the north, and IPUD and C3 to the east. The subject property is separated from properties to the east by Federal Highway and from properties to the west by Old Dixie Highway and the FEC railroad. The proposed residential community will buffer itself from any negative impacts associated with said right-of-ways. The proposed project is compatible with the adjacent uses and will not negatively impact property values. Conversely, the new development project will have a positive impact on the value of surrounding properties; and is likely to spur investment in adjacent properties which will further increase their values. f. Whether the property is physically and economically developable under the existing zoning. Currently zoned as C3, C5, CG and RM, the property's intensity potential is 112,850 s.f. 28 units, a third of that proposed by the Special High Density Residential and IPUD designations. The property's proximity to Federal Highway, Old Dixie Highway, and the FEC Railroad, as well as its location within the CRA, are important considerations that support the requested designation. Rezoning to IPUD, pursuant to the Special High Density Residential land use category, will enable an economically viable, timely redevelopment project to be developed on the site. ti<}{! 1t7N,~--_.m._~ " ~'"'3+' 4ii4O t,;;~ ' > .7!oO .' + .... .... . ~';';i! .ll~ .il_t9".~~--'-": ,I)+tH!____ I wml. fU.1 M32 i ~ " ~ ; "". .... ~~i .... ~ """, ,-' MiiJ.-:t\~(- ,Hm" .~_~-H'''''w- ;""'i"'~' 'MoMi '""" +1St .... I)tz+ ~, WPB:214174:1 RUDEN, McCLOSKY, SMITH, SCHUSTER & RUSSELL, P.A. CARACAS. FT, LAUDERDALE · MIAMI · NAPLES. PORT ST, LUCIE · SARASOTA. ST. PETERSBURG · TALLAHASSEE . TAMPA. WEST PALM BEACH Page 4 g. Whether the proposed rezoning is of a scale which is reasonably related to the needs of the neighborhood and the city as a whole. The property is slightly less than 7.5 acres in size, and has a double-frontage configuration between Federal Highway and Old Dixie Highway/FEC corridor. The aesthetic quality of the proposed redevelopment project will greatly improve the visual impacts of the property on the corridor, which is viewed as the gateway into the downtown and is targeted for aesthetic improvements. The requested land use change and rezoning will facilitate the redevelopment of the antiquated land use pattern in a manner consistent with the Federal Highway Corridor Community Redevelopment Plan. h. Whether there are adequate sites elsewhere in the city for the proposed use, in districts where such use is already allowed. The Special High Density Residential land use designation, as established by Policy 1.16.1 of the City's Comprehensive Plan, is a desired land use in the subject area, Planning Area V, to promote redevelopment and infill residential uses. The requested land use is only permissible in Planning Areas I and V of the Federal Highway Corridor portion of the CRA. The subject property has been identified for redevelopment by its inclusion in the CRA boundaries and within the Federal Highway Corridor Community Redevelopment Plan. IPUD Master Plan A Parkside conceptual Master Plan has been submitted, which proposes 122 townhomes on the subject 7.402 acres, for a density of 16.35 dulac. The Applicant offers documentation to demonstrate new demand generated by development under the proposed zoning (IPUD). The Applicant feels that any impacts can be mitigated to ensure compliance with concurrency requirements. Parkside will be developed in one phase, with an anticipated completion date of June, 2008. Residential development in the area is exempt from countywide traffic performance standards. Other public facilities and services will not be negatively impacted by the change in uses. Water and sewer demand, based on the rates identified in the attached tables, have been WPB:214174:1 RUDEN, McCLOSKY, SMITH, SCHUSTER & RUSSELL, P.A. CARACAS · FT, LAUDERDALE · MIAMI. NAPLES · PORT ST. LUCIE · SARASOTA. ST. PETERSBURG . TALLAHASSEE . TAMPA. WEST PALM BEACH Page 5 evaluated and the resulting demand can be served by the programmed capacity at the City's water and sewer treatment plants. Population projections under the existing and proposed uses are compared below. These estimates are based on the 2000 Census figure of 2.27 persons per unit as a citywide, average household size. Existing Land Use: Maximum Potential County- RM5 and CH/5 City - LRC and GC 10 du' s 23 persons Proposed Use: Maximum Potential SpHDR 148 du's 336 persons IPUD Considerations In addition to typical rezoning standards, the proposal is consistent with the locational and internal standards for Planned Unit Developments: Relation to Major Transportation Facilities: The property lies along the Federal Highway and Old Dixie Highway/FEC Railroad corridor, south of Woolbright Road. Palm Tran, the County bus service, has an established route, Route 1, which traverses US Highway One in twenty minute intervals. The nearest Tri-Rail station is located at Gateway Boulevard, just west of 1-95; but another is located south of Atlantic Avenue, west ofI-95. Relation to Utilities, Public Facilities and Services: The surrounding area is developed and served by a full compliment of City services. The proposed redevelopment project will maximize utilization of public facilities and will promote efficient service delivery. Physical Character of the Site: The 7.402-acre property has double-frontage along Federal Highway and Old Dixie Highway. The individual parcels were previously cleared, half lie vacant, but four are improved with single-family homes and one has a commercial building. The property does not contain environmentally sensitive lands or natural resources. The property is generally characterized by the St. Lucie-Urban-Paola soil association and is suitable for development. Access: The property is accessed via Federal Highway and Old Dixie Highway. WPB:214174:1 RUDEN, McCLOSKY, SMITH, SCHUSTER & RUSSELL, P.A. CARACAS' FT, LAUDERDALE - MIAMI- NAPLES - PORT ST. LUCIE. SARASOTA - ST, PETERSBURG' TALLAHASSEE . TAMPA' WEST PALM BEACH Page 6 Internal Lots and Frontage: The proposed townhomes are oriented internally and will not directly front (access) Federal Highway. All of the dwelling units will be accessed via an internal roadway. The proposed redevelopment project will be bounded on its perimeter by a landscape buffer. This landscaping will serve as the right-of-way frontage and immediate view of the development. Off-Street Parking: Required parking to serve the proposed 122 residential units will be provided on-site. No parking within public streets or right-of-ways is proposed. Underground Utilities: All new utilities serving the proposed townhome community will be located underground. Existing utilities that conflict with construction, required improvements or landscaping will be relocated or moved underground. Right-of-Ways: The subject property lies east of Old Dixie Highway and west of the Federal Highway. No right-of-way needs or additional dedications are anticipated WPB:214174:1 RUDEN, McCLOSKY, SMITH, SCHUSTER & RUSSELL, P.A. CARACAS · FT. LAU DERDALE · MIAMI' NAPLES · PORT ST, LUCIE · SARASOTA · ST, PETERSBURG · TALLAHASSEE . TAMPA' WEST PALM BEACH r-- Q) bI) c<::l P-. en ...... Or-- 0"0 ,..l:l Q) u Q) VJZ 4-< :::: 0 o en ..;:: Q) c<::l-.o I-< ~"O~ g ~ '<T P:::Z- or) :::: u .s s~ c<::l I-< I-< Q) E-< ~ o Q) ..... en c<::l"T ~ g .- ..... c<::l I-< "0 Q) .- :::: ...... Q) ao I-< Q) ~ Q)<"l VJ"O l::< [;l E S c<::l Q) ~Q '" :::: ~ 0 .,C .~ ::::-; E 0.. o 0 P-.P-. Z o VJ ~ P-. ::8 o U E-< U ~ P-. ::8 ....., ..... :::: Q) S 0.. o 03~ :> .- Q) ..... o ~ ..... s 0 ;::jP-. S .~ ::8 ~ VJ :::J ~ ~ ....:l - en 01 II 01 'E II ~ II .g S "0 ,..l:l ;::j Q)._ bI) ~ ~::8~~ en ~ 1a 0.. 15 0.. \0 \0 l/i >-. c<::l "0 --- en ::9 01 ...... o 01 "0 "0 5E5E (0 r-- - r-- '<T(0 ~ '<T~ - - en :::: o en I-< Q) 0.. l/i l/i ;::j ;::j "O~ 'tl S O'<T- - - 00 U P::: ....:l Q)cJ ::30 "0 ~ ::::~ c<::l::r:: ....:lu bI) ~ ::::l/i 't5 ~ . ~ 6::: ~ en ~. .j-D 'E 0 l/i Zl - II O\.g - II r-- ~ II ~ II .E II ~ II "2 S"O,..l:lenS"O,..l:l..... Q) ~ bI) ___ Q) ~ bI) en ~::8~N~::8~~ 4-< o en Q) I-< U c<::l 01] 0\ 0.. ..... ,..l:l 0.. o 00 ~ "0 --- en ::9 00 \0 (0~ 01 "0"0 5E5E NO V) 0 (0'<T l/i~ '<T~ l/i'<T en :::: o \0 ~ \0 Q) (00.. ...... c<::l .- 8 Q) S S o u c....; en (0 - '<T~ ;::j "0 00 '<T - Q) en :::J "0 [;l ....:l~ "OP::: Q)Q i!5::r:: 0..0.. OVJ I-< '-" P-. 4-< o en Q) I-< ~ en 0\] \00.. ..... ,..l:l 0.. \0 \0 00 o II o o "'<::1.0 ~o ~JL :E g ...<:: U tI) ...<:: Cl) 'O:.E ~ II o o -5""" tI)~ ~ II "00 '8 ..8 U tI) >-. c<::l "0 --- en .D - 01 l/i O\~ - r<) o ~ r<) + ~ r.I.. C ....l o \D \D i c ....l "0"0 5E5E 00 0 NO \0 \0 ~ \O~ '<T (0 Il) ~:a "0 '8 -.s 0 ~ 0 IX ...<:: -- U -; tI) .u ;>, .. .... ;>. ~ .s ~ -i'5 6 I=: 00 ~ 'i;jg S~ U g U ~ II o --f '0 g Jl~ ..8 N N ~ U .... c;l tI) 15.. II ~C -; ~ ._ cd I=:'u 81:: .g ~ cd C1) ~ 6.0 ~8 ;3 E .- <L> <L> 0. 06 C'hv o ....; U ~ I=: 0.1=: I Vi Cl) <L> ;>. ~ '~] -i'5.5 11 ;::lUUirJJ ro o ro::e ~ ;>, o^ ...<:: t '<I' 6:-;:::: 11 1?n~\D<r)o,tI).....8o ro..... I=:.....rou ....ro ...OIl)'H. C1) ~ ~ rIJ ~ ;.::: .~ ~ ~~.-==(1)~..::::_ II ~ ~ ~ 6' ~ ~ ~ '8 ,9 ] ~ g .... .... <8 ;::l"O~o.<8<8. Cl)EIXE-....tI)tI)~ s::: 0 Il) Il) Il) Il) ~ ~ ~ ~ ~ ~ c:) ~ t9 ~"O ~ ~'"O i$ 0 ,:2 ~ ~ s::: s::: . "0 '.p ..... .J _ 0 0 ro ~ 0.. ~ I-oLl ~ ".0 -- ::= 15.. 8 ~ ,&;;; ~ ~ ';; tI)~tI)~o.ggtl)" s::: tI) tI) c,.... Il) Il) Il) ~ro~~~CJCJ~ ....11"Ooll)..........10 15..ro~::r:t;E[J r--88..>o:ro"O"O N)<Il)i5<n.8.8o N>-<Qi=l<Nr/.lr/.l~ en :::: o r-- ~ r-- Q) 01 0.. ;::j "0 01 01 - ~ ...... c<::l en o 0.. o I-< P-. Q) "0 .- en ] P-. '-" ~r<")..yVj-.or- ---- .... Il) ...<:: ..... o I U <: l.U co :::?: -' <: "'- >- Vl ~ <: "'- ::;;: <: >- . l.U ~ tR ~ ~ <: -' -' <: >- . lJ ~ ~ co Vl ~ l.U >- l.U "'- t-= Vl . -l' -l UJ <fl <fl :) ~ c(l ~ UJ f- <fl :) I <: U >- <fl &; <: ~ <: Vl . l.U o ~ -' I f- ~ <fl >-' ~ ~ <fl Vl o ~ -l 0 U "'- u · ~ ~ "'- Z ~ UJ o ::;;: :) <: ~ ~ . l.U ;;: o ~ l.U o ~ <: -' ~ '-'- . Vl <: u ~ <: u ~ r-- ~ "T ~ N C:i CL 3: Page 8 CONSISTENCY WITH COMPREHENSIVE PLAN The proposed land use change from commercial and medium density residential land use categories to Special High Density Residential is consistent with the City of Boynton Beach Comprehensive Plan and the City's Community Redevelopment Plans. Specifically, the land use amendment is consistent with and furthers the following City objectives: Urban Sprawl: Objective 1.13, Policy 1.13.4 The proposed land use discourages urban sprawl by creating a compact urban area. The redevelopment project will utilize land within the urban core versus on the suburban fringe of the City. The proposed residential project will maximize utilization of public services and provide for efficient service delivery. Residential: Objective 1.16, Policy 1.16.1 The proposed development project will implement the redevelopment strategy to create transition to the downtown urban form. Consistent with the recommendations of the Federal Highway Corridor Community Redevelopment Plan, the proposed Parks ide project provides intensity that is less intense than the central business district, but greater than surrounding areas, Also, consistent with redevelopment objectives, the proposed project will provide new housing in proximity to the downtown area that will support downtown businesses and general economic expansion of the redevelopment area. Range of Land Uses: Objective 1.19 The requested land uses fulfill this policy provision by providing new housing choices in proximity to the downtown area. Consistent with the Federal Highway Corridor Community Redevelopment Plan, the proposal maintains the residential character of the area, but provides new aesthetic development that will enhance the visual impact along the Federal Highway corridor, the City's gateway into the downtown. Visions 20/20: Objective 1.22, Policy 1.22.4 The proposed residential land use and requested density is consistent with redevelopment strategies to provide residential use within the downtown area and to transition intensities through the CRA boundaries. WPB:214174:1 RUDEN, McCLOSKY, SMITH, SCHUSTER & RUSSELL, P.A. CARACAS. FT, LAUDERDALE · MIAMI. NAPLES · PORT ST. LUCIE · SARASOTA. ST, PETERSBURG . TALLAHASSEE . TAMPA' WEST PALM BEACH Page 9 NEED FOR LAND USE Palm Beach County is known as the West Palm Beach/Boca Raton Metropolitan Statistical Area (MSA). Growth in this region originated in the south and moved northward. Palm Beach County's growth rate has increased steadily during the past fifteen (15) years. In 1980, the County has a population of approximately 587,000. By 1990, the County had reached a population of approximately 870,000, which represented an increase of nearly 48%. The County's growth rate between 1990 and 2000 is less than it was between 1980 and 1990 due to recessionary economic conditions in the early 90's. However, population growth has increased significantly since 1990, and the University of Florida's Bureau of Economic and Business Research (BEBR) project an increased rate of growth through 2010. Population is projected to increase from 1,008,300 in 2000 to 1,300,600 in 2010. Based on projected population growth, there is a need for additional residences to meet the growing needs ofthe City's population. The subject property's location presents an ideal site for a new residential project that is located in proximity to the downtown business district and Federal Highway corridor. This location will provide residences in close proximity to these businesses, and will eliminate the need to traverse the roadway network to access to shop, dine, and conduct business. WPB:214174:1 RUDEN, McCLOSKY, SMITH, SCHUSTER & RUSSELL, P.A. CARACAS · FT, LAUDERDALE · MIAMI. NAPLES' PORT ST, LUCIE · SARASOTA. ST. PETERSBURG . TALLAHASSEE . TAMPA · WEST PALM BEACH Page 10 Mass Transit / Multi-Modal Transportation 1. Identify the mass transit modes serving the amendment area, Palm Tran Route 1 travels Federal Highway between Palm Beach Gardens and Boca Raton. The Boynton Beach Tri-Rail station is within 4 ~ miles of the subject property, but is not conveniently accessed via Palm Tran. 2. Identify the change in demand resulting from this amendment. It can generally be assumed that the proposed land use will have a slight increase in traffic generation, and therefore transit trips. Palm Tran's stated level of service is no more than a 60-minute peak hour headway between successive trips. Ridership of Route 1 is reported at 1,483,398 with 30 minute peak frequency. The 40' bus serving this route has a peak hour capacity of 60 persons. Peak hour ridership data was not available from Palm Tran. Tri-Rail's average daily capacity if 450 seated passengers. Boardings and Alightings at the Boynton Beach station from November, 2003-April, 2004 demonstrate that the majority of weekday travelers board at this station in the morning to travel to another destination (work place) and return to this station in the evening. The train's peak hour ridership varies from 600 to 627 persons. A maximum, peak hour capacity could not be provided by SFRTA. The Property is within the City of Boynton Beach. At this time, the City does not provide an inter-city shuttle service, but provides a "shopper hopper" to specified shopping destinations. A goal of the MPO's 2025 Long Range Transportation Plan for Palm Beach County is to increase community buses operated by the bigger cities, including Boynton Beach, to supplement Palm Tran service routes. Therefore, once implemented, the Property may also be served by the local shuttle service. WPB:214174:1 RUDEN, McCLOSKY, SMITH, SCHUSTER & RUSSELL, P.A. CARACAS. FT, LAU DERDALE . MIAMI. NAPLES. PORT ST. LUCIE · SARASOTA' ST, PETERSBURG · TALLAHASSEE . TAMPA. WEST PALM BEACH Page 11 3. Identify the existing and planned mass transit routes and scheduled service (headway) for the amendment area. According to Palm Tran website data, Route 1 is served continuously between 5:30 am and 10: 1 0 PM in 20-minute intervals on weekdays and 30-minute intervals on weekends. No new routes are identified for the amendment area. The Boynton Beach Tri-Rail station is served in the southbound direction between 4:42 AM and 11 :02 and between 2: 18 PM and 8: 18 PM, in hour intervals; and is served in a northbound direction between 5:47 AM and 12:47 AM and between 3:03 PM and 9:03 PM, in hour intervals. The MPO's FY 2004-2008 Transportation Improvement Program (and draft 2005-2009 TIP) identifies ongoing priorities to purchase of new and replacement buses, purchase of community shuttles and construction of bus shelters, which will implement the aforementioned goals of the LRTP. MPO's 2025 Transportation System Needs Plan identifies the need for extension of Tri-Rail to Martin County. The TIP programs monies for double-tracking, automated ticketing, and system extension planning. South Florida Regional Transportation Authority's Double Track Corridor Improvement Program, between Miami Airport and Mangonia Park is expected to be completed in 2005. 4, Describe how the proposed amendment furthers or is consistent with the concept of a "transit-oriented development". The proposed redevelopment project is conveniently situated in proXImIty to an established transit route that traverses the length of the County. Residents may chose to live in the proposed units due to accessibility to mass transit opportunities. WPB:214174:1 RUDEN, McCLOSKY, SMITH, SCHUSTER & RUSSELL, P,A. CARACAS · FT, LAU DERDALE . MIAMI- NAPLES. PORT ST. LUCIE - SARASOTA. ST, PETERSBURG - TALLAHASSEE · TAMPA · WEST PALM BEACH Parks ide Existing Land Use Water and Sewer Flow Estimate Water Uses No. of Units FI Residential 14 5,236 GPO Commercial 81,413 10,177 GPO 15,413 GPO Sewer Uses No. of Units Flow Residential 14 dwelling units 14 4,200 GPO Commercial 81,413 s . ft. 81,413 10,177 GPO 14,377 Notes: 1} Note for the purposes of calculation we used a 2 bedroom unit to calculate the total flow requirements for the project FLORIDA PUBLIC UTILITIES August 24. 2005 Eastcoast Communities 6499 North Power line Road Suite 101 Fort Lauderdale. FL 33309 RE: 120 Unit Townhouses at Miller Road Boynton Beach D~ar: Mr. Bryan S. Gershkowitz, As per your request, attached please find referenced plans showing the general location of our existing gas facilities, Note the exact locations of the facilities posted (plan and profile) needs to be confirmed by spot digging prior to fmalizing any underground design. We have an 4" gas main in the Old Dixie Highway that can serve this project. Our Markcting Department will be happy to provide information about the availability and advantages of using natural or propane gas. You can contact them directly by calling (561)838-1794. We would like to thank you for the opportunity to review this project. If you need any additional information or ifI can be of any further assistance, please feel free to contact me at (561)366-1518. Sincerely, ~~ k fL~_--:- Arnold K. Klein Engineering Technician Enclosure Cc Leb Stepherson Marketing Mgr. 401 South Dixie Hwy. A West Palm Beach, Florida 33401 k Phone: 561.832.0872 www.fpuc.com '-. '_('- ---7 ------ --- ---------- ---------- ------=: --=::::::::: --. -_ (~o ~ fa, ~~--:----- ~ I" ....- ~./".ISJ . . L 'I, ON 1 \, _tl. '. - _ ..q"o/1ly.')/;." - I .JP ~.;<] -- ~8 . ..... '. 9 H~~" :8 ~ H iB :8" I ' ~ --. -: 1 - I :" 1 1 ~n , ;1 1 , I I '-, --.-, -.-.,-- : ,I ~ .~ , , ~ 1 !i ~ !,;, :. i ~ : ~ I . 1 : 'I if. - I 'J g , 1 ..l ~ ~ 1 ! J i S 'I : -, i : I i -----~ ,:-'~ -....." -," , ____.. I - - I ~ ----.- i -lpo,if' ------- H:)IJ./ ~/J(IO ____ 010 '-~- _____ t/<J;?'3'.:1 _____ --- ---- ~ ,.. ... .,. C- C ~ ~ I. 4 ~ ~ ~~ t, ::. ~ '7 .,.. .. c:: :?: t;~N;: :x:;; ~ ~ r.t; ~ l ...: ~: e::: ... -< c ~. = W ~,' ; .. I t.~ .aD -!: ~ --. . FPL Florida Power & Light Company, 9329 S. Military TrJ., Boynton Beach, FL 33436 Phone: (561)742-2000 Fax: (561) 742-2016 September 8, 2005 Attn: Bryan S. Gershkowitz East Coast Communities 6499 North Powerline Road, Suite 101 Fort Lauderdale, FL 33309 Re: Proposed New East Coast Community T ownhomelCondominium Project V/O Federal Hwy and Old Dixie Hwy Boynton Beach, Florida Dear Mr. Gershkowitz: This is to confirm that, at the present time, FPL has sufficient capacity to provide electric service to the above captioned property. This service will be furnished in accordance with applicable rates, rules, and regulations. Please provide the final site plan, site survey, and electrical load data as soon as possible so the necessary engineering can begin. Early contact with FPL is essential so that resources may be scheduled to facilitate availability of service when required. Sincerely, -n0tc' Marietta Hicks Customer Project Manager II .1 1 1'1 i an FPL Group company @ IELLSOUTH BellSouth Telecommunications, Inc. Engineering Department 2021 So. Military Trail Room 107 West Palm Beach, FL 33415 Office: 561-439-9110 Fax: 561-964-3499 September 15, 2005 Bryan Gershkowitz 6499 N. Powerline Road, #101 Ft. Lauderdale, FL 33309 Re: Development on Federal Hwy in Boynton Beach Dear Sir: This letter is to confirm that BellSouth Telecommunications, Inc. will be the source of supply for telephone service with adequate capacity to the above referenced project, provided we are granted a means for our facilities to get to each individual unit (by recorded easement or conduit). It should be noted that BellSouth Telecommunications, Inc. does require an exclusive easement having dimensions of 25 feet by 25 feet for structures that house electronic switching equipment. (See attached Easement Document). The BellSouth representative who will be working with you and members of your organization on this development is Stephen R. Buck OSPE - Engineering. He can be reached at (561) 988-6507. Please contact the Engineer to schedule a Pre-Construction Meeting at your earliest convenience. During the Pre-Construction Meeting, various topics will be discussed to ensure successful and timely construction oftelecommunications facilities within the Subdivision. These topics will include scheduling of service dates for different residential building construction phases, procedures for damage prevention, damages to facilities and easements and rights-of-way required for placement of Bell South facilities within the development. Additional information regarding rights-of-way and easements in the development is provided below to facilitate BellSouth's placement of facilities. Florida Public Service Commission Rule 25-4.090(2) provides that the utility does not have any responsibility to provide local exchange service via underground facilities unless rights-of-way and easements suitable to the utility are furnished by the applicant in reasonable time to meet service requirements and, at no cost, cleared of trees, tree stumps, paving and other obstructions, staked to show property lines and final grade, and must be graded to within six (6) inches of final grade by the applicant all at no cost to the utility. The applicant must maintain the clearing and grading during construction by the utility. (See attached Certificate of Final Grade Document). Under the Rule, rights-of-way and easements must be cleared of paving and other obstructions, and the clearing must be maintained during construction by the utility. BellSouth cable is generally placed behind the curb/sidewalk in a utility easement; however, in certain places within the development, it will be necessary for the cable to cross the roadway. Ifroads, driveways and sidewalks are placed in advance of Bell South cable placement, the following alternatives exist to provide and maintain cleared rights-of-way and easements as required by the Rule: (1) placement of conduit for BellSouth where it will be necessary for BellSouth cable to cross the paved roadway, driveway and sidewalks or (2) maintaining gaps in the paved roadways and driveways and/or removing the paving in those areas for BellSouth when it commences construction to place cable. Note that conduit is not required for the cable, which can be direct buried in easements provided by the developer. But, if paving occurs prior to placement of the cable, the conduit essentially maintains a "clear" area for cable placement notwithstanding the obstruction created by the paving. If you choose to place conduit, BellSouth will work with you to provide crossing locations. BellSouth will attempt to call for crossings at locations where the electric company is crossing to minimize expense to the developer but requires information from the electric company on a timely basis to accomplish this goal. BellSouth will also, upon request when feasible, work with you on site when conduit crossings are placed and provide "electronic markers" to be placed at the appropriate locations. If placed, the conduit will be provided by the developer and should be 2- 4" schedule 40 PVC sleeves at the road and driveway crossing locations, placed at a minimum 24" depth, but not to exceed 30" below final grade, and should extend behind the curb/sidewalk 4' into the utility easement. The sleeves should terminate under a future grass area, not under a sidewalk or other obstruction. The ends of the sleeves are to be marked above ground or using "electronic markers" provided by BellSouth. If conduit exceeds 30" maximum depth, the developer will be responsible to expose the conduit on both ends and provide proper shoring per OSHA requirements. Below is a list of documentation and information that must be provided to the BellSouth representative associated with this project: CADD file ofthe project (overall site plan in either Microstation or AutoCAD format) Full size hard copy of overall site plan Full size copy of platted drawings Full size hard copy of water and sewer drawings Full size hard copy of electrical drawings (if multi-family or commercial buildings) Completed 25' by 25' Easement Documents in order to give service to your subdivision. Property Control # Address of each unit This information must be provided to the BellSouth representative a minimum of 4 months prior to the first expected service request. If temporary service to a construction trailer/office is requested prior to permanent service to the development, a charge for special construction may be required. The company shall have no responsibility to provide service unless these conditions are met. As always, we will work with you individually and help to resolve any particular issues you may have regarding these requirements. If you have any other suggestions regarding how our companies can work together to accomplish the desired and required ends, please let us know, If you have any questions, please do not hesitate to contact us. Sincerely, Stephen R. Buck OSPE - Engineering BellSouth Telecommunications, Inc. STATE OF FLORIDA COUNTY OF PALM BEACH EASEMENT For and in consideration of ten dollars ($ 10.00 ) and other good and valuable consideration, the adequacy and receipt of which is hereby acknowledged, the undersigned owner(s) of the premises described below, hereinafter referred to as Grantor, do(es) hereby grant to BELLSOUTH TELECOMMUNICATIONS, INC., a Georgia corporation, its licensees, agents, successors, assigns, and allied and associated companies, hereinafter referred to as Grantee, an easement to construct, operate, maintain, add, and/or remove such systems of communications, facilities, or related services as the Grantee may from time to time require upon, over, and under a portion of the lands described in page Palm Beach County, Florida, Records, and, to the fullest extent the grantor has the power to grant, upon, over, along, and under the roads, streets, or highways adjoining or through said property. The said easement is more particularly described as follows: All that tract or parcel of land lying in Section Meridian, , Township , Range County, State of Florida, consisting of a (strip) (parcel) of land The following rights are also granted: the exclusive right to allow any other person, fIrm, or corporation to attach wires or lay cable or conduit or other appurtenances upon, over, and under said easement for communications or electric power transmission or distribution; ingress to and egress from said easement at all times; the right, but not the obligation, to clear the easement and keep it cleared of all trees, undergrowth, or other obstructions; the right, but not the obligation, to trim and cut and keep trimmed and cut all dead, weak, leaning, or dangerous trees or limbs outside the easement which might interfere with or fall upon the lines or systems of communication or power transmission or distribution; and the right to relocate said facilities, systems of communications, or related services on said lands to conform to any future highway relocation, widening, or improvements. Grantee may use systems and facilities placed in the easement area to provide services to customers within or outside the development wherein the property that is the subject of this easement is located. To have and to hold the above granted easement unto BellSouth Telecommunications, Inc., its licensees, agents, successors, assigns, and allied and associated companies forever and in perpetuity. Grantor warrants that grantor is the true owner of record of the above described land on which the aforesaid easement is granted. SPECIAL STIPULATIONS OR COMMENTS: The following special stipulations shall control in the event of conflict with any of the foregoing easement: Preparer's name and address: (Return document to the BellSouth address on back) In witness whereof, the undersigneu'haslhave caused this instrument to be eXt.A1ted on the 200 day of Signed, sealed, and delivered in the presence of Name of Corporation By: Title: Witness Attest: Witness State of Florida County of I HEREBY CERTIFY that personally appeared before me and acknowledged that he/she was the same. The foregoing instrument was acknowledged before me this day of , by ,(name and title of officer) of corporation. He/she is personally known to me or has produced as identification and did/did not take an oath. WITNESS my hand and official seal in the County and State last aforesaid this day of Notary Public Print Name Commission Number: My Commission Expires: Grantor's Address: Grantee's Address: BellSouth Telecommunications, Inc. TO BE COMPLETED BY BELLSOUTH TELECOMMUNICATIONS, INC. District Wire Center Authority Drawing Location Plat Number RfW Number Approval Title Trat Tech ENGINEERING, INC, August 24, 2005 Mr. Robert Hall Principal East Coast Communities 6499 N. Powerline Road Fort Lauderdale, Florida 33309 Re: Parkside (Boynton Villas) - Traffic Study Dear Mr. Hall: Per your request, Traf Tech Engineering, Inc. conducted a traffic study for the Parkside (Boynton Villas) development planned to be located between Federal Highway and Old Dixie Highway in the City of Boynton Beach, Florida. The location of the project site is illustrated in Figure 1. The site is currently developed with four residential units and a small commercial building. This traffic study was conducted in order to document the traffic impacts generated by the proposed project. The traffic study addresses the following items: o Trip Generation Comparison Analysis o Driveway Analysis Trip Generation Comparison Analysis A trip generation comparison analysis between the parcel's existing and proposed land uses was conducted. The analysis was performed using the trip generation equations published in the Institute of Transportation Engineer's ITE Trip Generation Manual (th Edition). The trip generation comparison analysis was undertaken for daily, AM peak hour, and PM peak hour conditions. The analysis was based on the following assumptions: EXISTING LAND USE o Residential Four single-family homes o Commercial 1,400 square feet of commercial space PROPOSED LAND USE o Residential 121 townhomes 8400 North University Drive, Suite 307, Tamarac, Florida 33321 Tel: (954) 582-0988 Fax: (954) 582-0989 E-mail: joaquin@traftech,biz .....".' SE 23rd Avenue Project Site Trat Tech >- co 3: .J:: .2> I Q) :8 o :2 o - >- co 3= ..c 0> I co s- O> "'C 0> LL -- T""" CI) :J ENGINEERING. INC. Project Location Map >- co ~ 2 co $ co - en co o <.> co ..... - c '-" A <( ....... <( FIGURE 1 Parkside (Boynton Villas) Boynton Beach, Florida .. '" According to ITE's Trip Generation Manual (7th Edition), the most appropriate "land use" categories for the existing and proposed land uses are: SINGLE FAMILY HOMES (ITE Land Use 210) Daily Trips T = 9.57(X) Where T = average daily vehicle trip ends X = number of dwelling units AM Peak Hour T = 0.75(X) Where T = average AM peak hour vehicle trip ends X = number of dwelling units PM Peak Hour T = 1.01(X) Where T = average PM peak hour vehicle trip ends X = number of dwelling units TOWNHOMES CITE Land Use 230) Daily Trips Ln(T) = 0.85 Ln(X) + 2.55 Where T = average daily vehicle trip ends X = number of dwelling units AM Peak Hour Ln(T) = 0.80 Ln(X) + 0.26 Where T = average AM peak hour vehicle trip ends X = number of dwelling units PM Peak Hour Ln(T) = 0.82 Ln(X) + 0.32 Where T = average PM peak hour vehicle trip ends X = number of dwelling units COMMERCIAL (ITE Land Use 820) Daily Trips T = 42.94(X) Where T = average daily vehicle trip ends X = number of dwelling units AM Peak Hour T = 1.03(X) Where T = average AM peak hour vehicle trip ends X = number of dwelling units 3 Trat Tech ENGINEERING, INC. ,; PM Peak Hour T = 3.75(X) Where T = average PM peak hour vehicle trip ends X = number of dwelling units Using the above-listed equations from the ITE document, a trip generation comparison analysis was undertaken for the existing and proposed land uses. The results of this effort are documented in Table 1. TABLEt Trip Generation Comparison Analysis Parks ide (Bovnton Villas) Number of Trips Land Use Size Daily AM Peak PM Peak EXISTING LAND USE SF Homes 4 units 38 3 4 Commercial 1,400 sq.ft. 60 1 5 Total - 98 4 9 PROPOSED LAND USE MF Homes 121 units 755 601 702 I Difference I I 657 Source: ITE Trip Generation Manual (ih Edition) 56 61 As indication it Table 1, the proposed land use changes associated with the Parkside (Boynton Villas) development would result in 657 additional daily trips, 56 new AM peak hour trips, and 61 new trips during the PM peak hour. Driveway Analysis The AM and PM peak hour traffic volumes generated by the proposed residential development were assigned to the two project driveways (a right-turn in/right-turn out driveway off of Federal Highway and an outbound-only driveway on Old Dixie Highway). Based on the surrounding land uses and the transportation network located in the vicinity of the proposed project, the following trip distribution was assumed for the Parkside residential development: o Forty percent (40%) on Federal Highway north ofthe site o Forty Percent (40%) on Federal Highway south of the site o Ten percent (10%) on Old Dixie Highway north of the site o Ten percent (10%) on Old Dixie Highway south of the site 1 10 inbound trips and 50 outbound trips. 2 47 inbound trips and 23 outbound trips. 4 Trat Tech ENGINEERING. INC. " J Figure 2 depicts the AM and PM peak hour traffic assignments on the two project driveways. Based on the peak hour turning movement volumes developed for each driveway, the following driveway geometries are recommended for the subject project: FEDERAL HIGHWAY DRIVEWAY o One southbound shared through/right-turn lane (no improvements necessary on Federal Highway) o One right-turn-only exit lane OLD DIXIE HIGHWAY o One exit-only lane (shared left-turn/right-tum lane) Please give me a call if you have any questions. Sincerely, F TE~;~rtERJNG' INC. uin E. Vargas. p, ., TOE or Transportatio Engineer 5 Trat Tech ENGINEERING, INC. ........~ "'"""" LEGEND A 40 AM Peak Hour Trip (19) PM Peak Hour Trip - I'-- ~ -- 0 ~ ~ 5 (2) Project Site J ~ 5 (2) (19)40 ~ - >- >- co co 3: 3: ..c ..c 0> 0> I I - Q) co "- 'x Q) (5 '"C Q) '"C LL -- 0 T""" en ::> FIGURE 2 Trat Tech Driveway Traffic Assignment Parkside (Boynton Villas) ENGINEERING. INC. Boynton Beach, Florida Land Use: 210 Single-Family Detached Housing Description Single-family detached housing includes all single-family detached homes on individual lots. A typical site surveyed is a suburban subdivision. Additional Data The number of vehicles and residents have a high correlation with average weekday vehicle trip ends. The use of these variables is limited. however, because the numbers of vehicles and residents was often difficult to obtain or predict. The number of dwelling units is generally used as the independent variable of choice because it is usually readily available. easy to project and has a high correlation with average weekday vehicle trip ends. This land use included data from a wide variety of units with different sizes. price ranges, locations and ages. Consequently, there was a wide variation in trips generated within this category. As expected, dwelling units that were larger in size, more expensive. or farther away from the central business district (CBD) had a higher rate of trip generation per unit than those smaller in size, less expensive, or closer to the CBD. Other factors. such as geographic location and type of adjacent and nearby development, may also have had an effect on the site trip generation. Single-family detached units had the highest trip generation rate per dwelling unit of all residential uses, because they were the largest units in size and had more residents and more vehicles per unit than other residential land uses; they were generally located farther away from shopping centers, employment areas and other trip attractors than other residential land uses; and they generally had fewer alternate modes of transportation available, because they were typically not as concentrated as other residential land uses. The peak hour of the generator typically coincided with the peak hour of the adjacent street traffic. The sites were surveyed from the late 1960s to the 2000s throughout the United States and Canada. Source Numbers 1,4,5,6,7,8,11,12,13,14, 16, 19.20,21,26.34,35,36,38,40.71,72.84,91,98,100,105, 108,110,114.117,119,157,167,177, 187, 192,207,211.246,275.283,293,300,319,320, 357,384,435,550,552,579 Trip Generation, 7th Edition 268 Institute of Transportation Engineers ~ .~ i $ 'l Single-Family Detached Housing (210) t :1 I Average Vehicle Trip Ends vs: Dwelling Units On a: Weekday Number of Studies: Avg. Number of Dwelling Units: Directional Distribution: 350 197 50% entering, 50% exiting Trip Generation per Dwelling Unit Average Rate Range of Rates Standard Deviation 9.57 4.31 - 21.85 3.69 Data Plot and Equation I;? I" ~ , ~~ : 30.000 en 'tl c: W ,g. .= al (3 :E al > al Cl Cll CD > oCt: II ~ ../' / / . / .........~ x .' / ....../ 20,000 x; i x I 10.000 -: .5< x o x x o 1000 2000 3000 x = Number of Dwelling Units X Actual Data Points Fitted Curve - - - - - - Average Rate Fitted Curve Equation: Ln(T) = 0.92 Ln(X) + 2.71 R2 = 0.96 i,Trip Generation, 7th Edition 269 Institute of Transportation Engineers Single-Family Detached Housing (210) Average Vehicle Trip Ends vs: On a: Dwelling Units Weekday, Peak Hour of Adjacent Street Traffic, One Hour Between 7 and 9 a.m, Number of Studies: Avg. Number of Dwelling Units: Directional Distribution: 274 201 25% entering, 75% exiting Trip Generation per Dwelling Unit Average Rate 0.75 Range of Rates Standard Deviation 0.33 2.27 0.90 Data Plot and Equation 3,000 CIl -g 2,000 1 w a. ~ co 13 E Q) > co Cl <1:l Cii > ~ 1,000 ~ I- x " /' ~ -- /" , /'" .-' ,// ~ ~ /.... // ,,' // // ".,;.// .-'/ ",/ , ..- , / "","'/-" ,,'/ ,',,/ ...."'// ,/' ".... x ,;.:<;' x ,'x ' y! x x >< o o 1000 2000 3000 x = Number of Dwelling Units x Actual Data Points Fitted Curve - - - - - - Average Rate Fitted Curve Equation: T = 0.70(X) + 9.43 R2 = 0.89 Trip Generation, 7th Edition 270 Institute of Transportation Engineers Single-Family Detached Housing (210) Average Vehicle Trip Ends vs: Dwelling Units On a: Weekday, Peak Hour of Adjacent Street Traffic, One Hour Between 4 and 6 p.rn, Number of Studies: 302 Avg, Number of Dwelling Units: 214 Directional Distribution: 63% entering, 37% exiting Trip Generation per Dwelling Unit Average Rate 1.01 Range of Rates Standard Deviation 0.42 2.98 1.05 Data Plot and Equation 3,000 x en '0 C W ,g. ~ Q) :2 .r: Q) > OJ Cl ltl Qi > :ex: II ~ ,< x /' / /~ / /'/ ../ //" // /' ,/' X // ,//,/ 2,000 --: ,< /, x..... // /' /' x " ../" ,..../ Y. 1,000 ~ )( o o 1000 2000 3000 x = Number of Dwelling Units ;>< Actual Data Points Fitted Curve - - - - - - Average Rate Fitted Curve Equation: Ln(T) = 0.90 Ln(X) + 0.53 R2 = 0.91 Trip Generation, 7th Edition 271 Institute of Transportation Engineers Land Use: 230 Residential CondominiumlTownhouse Description Residential condominiums/townhouses are defined as ownership units that have at least one other owned unit within the same building structure, Both condominiums and townhouses are included in this land use. The studies in this land use did not identify whether the condominiums/townhouses were low-rise or high-rise. Low-rise residential condominium/townhouse (Land Use 231), high-rise residential condominium/townhouse (Land Use 232) and luxury condominium/townhouse (Land Use 233) are related land uses, Additional Data The number of vehicles and the number of residents had a high correlation with average weekday vehicle trip ends. The use of these variables was limited, however. because the number of vehicles and residents was otten difficult to obtain or predict. The number of dwelling units was generally used as the independent variable of choice because it is usually readily available, easy to project and had a high correlation with average weekday vehicle trip ends. The peak hour of the generator typically coincided with the peak hour of the adjacent street traffic, The sites were surveyed from the mid-1970s to the 2000s throughout the United States and Canada. Source Numbers 4,92.94.95,97.100,105.106.114, 168, 186,204.237,253,293.319,320.321,390,412,418. 561,562.583 J ~ " j j , i Trip Generation, 7th Edition 366 Institute of Transportation Engineers Residential Condominiumn-ownhouse (230) Average Vehicle Trip Ends vs: On a: Dwelling Units Weekday Number of Studies: Avg. Number of Dwelling Units: Directional Distribution: 54 183 50% entering, 50% exiting Trip Generation per Dwelling Unit Average Rate 5.86 Range of Rates Standard Deviation 1.83 11 .79 3.09 Data Plot and Equation 8,000 ,.------ 7,000-' 6,000 -+ CIl "C c:: UJ 9- .= Ql u E Ql > Ql C) C1l CD > <( II r- 2,000 - ~' ~ ~" ~ /-:"~ /// ///--' ,// ,/' /// / x,, /// ,<,/ ,'>/ x Xx;/' x XX- ,/ 'X '/'x , x/x 1'OOOl.;x ,,)t j x x . y X/x x 5.000 -; x 4,000 - 3.000 -; x :i' x o ~ -----;- o 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 x = Number of Dwelling Units Y Actual Data Points Fitted Curve - - - - - - Average Rate Fitted Curve Equation: Ln(T) = 0.85 Ln(X) + 2.55 R2 = 0.83 Trip Generation. 7th Edition 367 Institute of Transportation Engineers " :! ~ . .~ J Residential CondominiumlTownhouse (230) Average Vehicle Trip Ends vs: On a: Number of Studies: Avg. Number of Dwelling Units: Directional Distribution: Dwelling Units Weekday, Peak Hour of Adjacent Street Traffic, One Hour Between 7 and 9 a,m. 59 213 17% entering, 83% exiting Trip Generation per Dwelling Unit Average Rate 0.44 0.15 Range of Rates 0.69 Standard Deviation 1.61 Data Plot and Equation en 'C c:: W ,9- ~ Q) 13 :.c Q) > Q) Cl ~ Q) > <( 1/ r- , x ~ ..~ ..~x/ " ~/ xX",~/ X 600 I I 500 1 400 300 ~1 x x ~ i I I 100 -\ I I ~ I I I o : o x x 100 200 300 400 500 x = Number of Dwelling Units - - - - - - Average Rate Fitted Curve Equation: Ln(T) = 0.80 Ln(X) + 0.26 X Actual Data Points Trip Generation. 7th Edition ,~ x' x x' 600 700 800 900 1000 1100 1200 1300 Fitted Curve R2 = 0.76 368 Institute of Transportation Engineers .~ i I 1 Residential CondominiumITownhouse (230) Average Vehicle Trip Ends vs: Dwelling Units On a: Weekday, Peak Hour of Adjacent Street Traffic, One Hour Between 4 and 6 p.m. Number of Studies: 62 Avg. Number of Dwelling Units: 205 Directional Distribution: 67% entering, 33% exiting Trip Generation per Dwelling Unit Average Rate Range of Rates 0.52 Standard Deviation 0.75 0.18 1.24 Data Plot and Equation 500 CIl 'tl c: W a. ~ 400 ell (3 E ell > , Ql 300i Ol as Q; > <t: " 1/ I l- i , 200 -: ! 1 100 -+ j I 0 ! 0 700 , I 1 600 -+ i ,- ~' "'~ ~ " / x ,./~ x ,~ .,,' -~ , x / x ,>' x x ~x 100 I 300 400 I 500 600 700 800 900 1000 1100 1200 200 x = Number of Dwelling Units X Actual Data Points Fitted Curve - - - - - - Average Rate Fitted Curve Equation: Ln(T) = 0.82 Ln(X) + 0.32 R2 = 0.80 Trip Generation. 7th Edition 369 Institute of Transportation Engineers x i I 1 I I I I i I I I I I I i i I i 1 i I ! 1300 Land Use: 820 Shopping Center Description A shopping center is an integrated group of commercial establishments that is planned, developed, owned and managed as a unit. A shopping center's composition is related to its market area in terms of size, location and type of store. A shopping center also provides on-site parking facilities sufficient to serve its own parking demands. Specialty retail center (Land Use 814) and factory outlet center (Land Use 823) are related uses. Additional Data Shopping centers, including neighborhood centers, community centers, regional centers and super regional centers, were surveyed for this land use. Some of these centers contained non- merchandising facilities, such as office buildings, movie theaters, restaurants, post offices, banks, health clubs and recreational facilities (for example, ice skating rinks or indoor miniature golf courses). The centers ranged in size from 1,700 to 2.2 million square feet of gross leasable area (GLA). The centers studied were located in suburban areas throughout the United States and therefore represent typical U.S. suburban conditions. Many shopping centers, in addition to the integrated unit of shops in one building or enclosed around a mall, include outparcels (peripheral buildings or pads located on the perimeter of the center adjacent to the streets and major access points). These buildings are typically drive-in banks, retail stores, restaurants, or small offices. Although the data herein do not indicate which of the centers studied included peripheral buildings, it can be assumed that some of the data show their effect. The vehicle trips generated at a shopping center are based upon the GLA of the center. In cases of smaller centers without an enclosed mall or peripheral buildings, the GLA could be the same as the gross floor area of the building. Separate equations have been developed for shopping centers during the Christmas shopping season. Plots were included for the weekday peak hour of adjacent street traffic and the Saturday peak hour of the generator. Information on approximate hourly, monthly and daily variation in shopping center traffic is shown in Tables 1-4. It should be noted, however, that the information contained in these tables is based on a limited sample size. Therefore, caution should be exercised when applying the data. Also, some information provided in the tables may conflict with the results obtained by applying the average rate or regression equations. When this occurs, it is suggested that the results from the average rate or regression equations be used, as they are based on a larger number of studies. Trip Generation, 7th Edition 1448 Institute of Transportation Engineers a 21.38 Shopping Center (820) Average Vehicle Trip Ends vs: On a: 1000 Sq. Feet Gross Leasable Area Weekday Number of Studies: Average 1000 Sq. Feet GLA: Directional Distribution: 302 328 50% entering, 50% exiting Trip Generation per 1000 Sq. Feet Gross Leasable Area Average Rate Range of Rates 42.94 12.50 - 270.89 Standard Deviation Data Plot and Equation 70,000 x 60,000 20,000 x , , X," x y. x x,' x X x X x x, x' x x ~ x x /- ~x x x x x x X ~:ox x x x x x x y x x ~ I I , I , I , 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 50,000 en 1:l c: W 0- 'i:: t- ell C3 :c ell > ell Cl ell "- ell > <( II t- 40,000 30,000 10.000 1 o o x = 1000 Sq. Feet Gross Leasable Area )( Actual Data Points Fitted Curve - - - - - - Average Rate Fitted Curve Equation: Ln(T) = 0.65 Ln(X) + 5.83 R2 = 0.78 Trip Generation, 7th Edition 1451 Institute of Transportation Engineers Shopping Center (820) f .' I' I ; - -.. ._-~ ~--- _._----~_.- -----. J ] ~ , ,~ J .~ ; 1 ! ;~ ~ ~ " ~ i , ~ :~ J 4 .t ~; I .\ '1 i' :} ;J I i ; "~ 'I 1 ~ ,1 Average Vehicle Trip Ends vs: Ona: 1000 Sq. Feet Gross leasable Area Weekday, Peak Hour of Adjacent Street Traffic, One Hour Between 7 and 9 a.m. ~-- -~--_.- ~-..- ..-.-. -----.---- ------ .._-,-. ._._~.----,._-~_._._-_. ------ Number of Studies: Average 1000 Sq. Feet GLA: Directional Distribution: 98 287 61% entering, 39% exiting Trip Generation per 1000 Sq. Feet Gross leasable Area Average Rate Range of Rates ------ 1.03 0.10 Standard Deviation 9.05 1.40 Data Plot and Equation 1,600 1,500 -: 1.400 -, 1.300 1,200 x en 1,100 '0 c: w ,9- 1,000 - ~ Q) 900 ~ U 1 i: I Q) 800 1 > Q) Cl 700 <ll CD > 600 <( II X ;< ~ 500 j<., ,; y ~~- Y' x -----'~- y !~-- x ~ x: )< ,< _/-~ Y .\-.--- - -<;( XX ____ / X 400 1 ~ x - x.>( ,:,~)y"'~'- i /' ::./ ',( 3001" x/xx ~ ~.>(:xx /, I, /,/(/. 'S<-'% 200 -t ~}('x x' ~j. y'f<i)( 100 -< /' , X o. . ~ ~--r-~r--~~ o 100 200 300 400 500 600 x " y' I -'r---r---~--------:----r----' 700 800 900 1000 1100 1200 1300 1400 1500 1600 x = 1000 Sq. Feet Gross Leasable Area >< Actual Data Points Fitted Curve - - - - - - Average Rate Fitted Curve Equation: Ln(T) = 0.60 Ln(X) + 2.29 R2 = 0.52 Trip Generation, 7th Edition 1452 Institute of Transportation Engineers Shopping Center (820) Average Vehicle Trip Ends vs: Ona: Number of Studies: Average 1000 Sq. Feet GLA: Directional Distribution: 1000 Sq. Feet Gross Leasable Area Weekday, Peak Hour of Adjacent Street Traffic, One Hour Between 4 and 6 p.m. 407 379 48% entering, 52% exiting Trip Generation per 1000 Sq. Feet Gross Leasable Area Average Rate Range of Rates 3.75 0.68 - 29.27 Standard Deviation 2,75 Data Plot and Equation 9,000 -,------ ----- I j I 8,000 -1 7,000 '" "0 6,000 c w ,s. .= aJ 5,000 i (3 1:: aJ > aJ 4,000 Cl <tl CD > <( 1/ 3,000 ~ 2,000 x x x x ~ ,,'0/ o ;< /. x x X .x x ;.< x -- ..-- ._r---- ')( ~ >( ./ -~---- '/ ---- 'X )( .' x o --1----,~,---- 1000 2000 x = 1000 Sq. Feet Gross Leasable Area / Actual Data Points Fitted Curve Equation: Ln(T) = 0.66 Ln(X) + 3.40 Trip Generation, 7th Edition Fitted Curve - - - - - - Average Rate R2 = 0.81 1453 I ! I I i I I j I i I I I I 3000 Institute of Transportation Engineers 4, PROJECT NAME: Palm ~ove fka Miller Road Project ,,4., LOCATION: East of Old Dixie Hwy; West of Federal; North of Gulfstream Blvd. PCN: I FILE NO.: NWSP 05-031 II TYPE OF APPLICATION: I AGENT/CONTACT PERSON: OWNER: Multiple Ruden-McClosky ADDRESS: ADDRESS: 222 Lakeview Avenue # 800 West Palm Beach, FL 33401 FAX: FAX: 561-514-3442 PHONE: - PHONE: 561-838-4542 SUBMITTAL / RESUBMITT AL 9/21/05 1 ST REVIEW COMMENTS DUE: 10/7/05 PUBLIC /IP ARC NOTICE: Applicant Only: 12/2/05 TART MEETING: 10/25/05 LAND DEVELOPMENT SIGNS POSTED (SITE PLANS): LEGAL AD: PLANNING & DEVELOPMENT BOARD MEETING: COMMUNITY REDEVELOPMENT 12/13/05 AGENCY BOARD CITY COMMISSION MEETING: 1/3/2006 COMMENTS: S:\Planning\SHARED\WP\PROJECTS\PARKSIDE\NWSP 05-031 \2005 PROJECT TRACKING INFO,doc 1..I."VV"J1vNINGHAIVI & FRADLEY" INC. il," ENGINEERS - PLANNERS - SURVEYORS November 7, 2005 !: : r, : " ' ,~ " DRAINAGE STATEMENT for Palm Cove NOV - 8 2005 i_ Introduction Palm Cove is a proposed townhouse project located on O.S, Highway No,l (S,R, 5) and Old Dixie Highway in the City of Boynton Beach and contains 7.402 Acres of land, Currently the property contains six existing structures. The property slopes from west to east and drains into the D,S, Highway No. 1 right of way, unrestricted. The existing property has no evidence of any existing water management facilities, This project proposes the construction of 121 Townhomes with a Recreation Center/Pool Facility, The proposed building coverage for this project is 2.65 Acres with an additional 2.73 Acres of impervious area, The remaining portion of the site will be green containing 2,027 Acres. The water management system will consist of an exfiltration system that will contain the storm water run-off from the proposed project, Discharge into the D,S, Highway No, 1 right of way will match the pre-developed discharge rate, The propose discharge method will be similar to the existing property, over land flow into the right of way, The detention volume will be stored within the exfiltration trench and a low green area located at the recreation area, No wet detention is proposed on this project, SFWMD and FDOT drainage permits will be required for project approval, Proposed Improvements The proposed land-use breakdown is as follows: Green: Impervious: Buildinqs: Total: 2.027 2.73 2.645 7.402 Ac. Ac. Ac. Ac. Abstraction for the property: (8.18") (2.027 Ac.) (1'/12")=1.38 Ac-Ft, 25 Year,3 Day Event: 13 Inches of Rain Fall Per SFWMD Figure C-8, (13") (7,402 Ac,) (1'/12")= 8.02 Ac-Ft. Storage Required. 7154 S,E OSPREY STREET, HOBE SOUND, FLORIDA 33455 772-546-5466 FAX: 772-546-4475 storage Provided in 1977 feet of Exfiltration Trench: (See Exfiltration System Calculations) (7.93") (7.402 Ac.) (1'/12")=4.89 Ac-Ft. Above Ground Storage Required during 25 Year storm event: (8.02 - 1.38 - 4.89)= 1.75 Ac-Ft. (Surplus Water) Pervious and Impervious Area of the site: 4.75 Acres Average Depth of surface water on the site. (1.75 Ac-Ft.)/(4.75 Acres) = 0.37 Ft. The average depth of water on the site during a 25 Year, 3 Day Storm event is 0.37 Feet. 5 Year,l Day Event(Parking Lot): 7 Inches of Rain Fall Per SFWMD Figure C-3. (7") (7.402 Ac.) (1'/12")= 4.32 Ac-Ft. Storage Required. Storage Provided in 1977 feet of Exfiltration Trench: (7.93") (7.402 Ac.) (1'/12")=4.89 Ac-Ft. Above Ground Storage Required during 5 Year storm event: (4.32 - 1.38 - 4.89)= (-)1.95 Ac-Ft. Surplus Provided Pervious and Impervious Area of the site: 4.75 Acres The average depth of water on the site during a 5 Year, 3 Day Storm event is 0 Feet. Storage provided below the ground elevation. A General Permit Application will be submitted to the SFWMD for the proposed site plan. The engineering plans for the proposed site will comply with the original SFWMD permit criteria. WINNINGHAM & FRADLEY, INC. J.j', 4'/ /..). ~ 'I/", -f-..- I"~r:~t~s.' ~es~g P.E. License Engineer No. 40046 State of Florida Date: 22.Qct-2005 By GSB Proj~ Palm Cove Description: Exfilt I Storage for Detention EXFILTRATION SYSTEM DESIGN 1 , Site Runoff Data: 1 ,1 Area Breakdown 1,1,1 Lake and lake bank, AI...............,................................... == 1.1,2 Dry retention area, Ad ............................................... 1,1,3 Roofs (connected to the drainage system), Ar* .......,..... == 1,1,4 other impervious areas, Ai .................................. 1,1,5 Green areas, Ao .,..,......,..........,.........................,.... 1.1.6 Total area, At ........................................................... -- 1.2 Imperviousness for Water Quality Calculations: 1.2.1 Site area*, Aqs=At-(AI+Ar) ,..........,..,...,............... 1.2.2 Impervious area., Aqi=Aqs-(Ao+Ad) ........................... -- 1.2.3 Impervious percentage*, IP=(Aqi/Aqs)(100) ............. -- 1.3 Runoff, R: 1.2,1 Method A, Ra=(1/12)(At)...............................m....,.....,m == 1.2.2 Method B, Rb=(2,5112)(IP/1oo)(At-AI) .......,..........,.., 1,2,3 Runoff, R=MAXIMUM(Ra,Rb) ,..............................., 1.4 1 ,~, 1 P~~treatment, P=1/2..xAt-AL................................... 2 "K" value per project in area 3, Trench Design Data: 3,1 Trench width, W .........................,..,..,.............m.............. 3,2 Unsaturated trench height, Hu .........,.......................,...,... 3,3 Saturated trench height, Hs ................,............................. 3.4 Maximium head on trench, h .....................'........m............ 3,5 Length of trench, L ..........................................................., 4. Trench Exfiltration Data: 4.1 Bottom exfiltration, Eb=3600(L)(W)(h)(K) ......'...........m 4.2 Unsaturated side exfiltration, Eu=7200(L)(Hu)(K)(h-Hu/2)......., 4,3 Saturated side exfiltration, Es=7200(L)(Hs)(h)(K)............ 4.4 Total trench exfiltration, E=Eb+Eu+Es ,........................... 5, Storage Data: 5,1 Pipe Storage, Vp: Pipe diameter ...."".,..,."."""""""""""'..""'.....,.,....".,,.,,.. Submerged depth of pipe........,...................................... Area of pipe above water, Ap ............................................' Length of pipe, Lp ..,..................................,...........,........... Pipe volume, Vp=(Lp)(Ap) ................,....................,...,......' 5.2 Trench Storage, Vt: Gross area above water, Ag=(W)(Hu) ...........m..,....m""m, Net area, An=O,5(Ag-Ap) ,.........................,..........,............ Trench volume, Vt=(An)(L) ...........................m..,............,..m 5,3 Dry Storage, Vd: 5.3,1 Retention Depth, Dr ................................m........... 5.3.2 Volume, Vd=1 ,5(Ad)(Dr) m..,................,m........""",,", 5.4 Total Storage, S=Vp+Vt+Vd ....,......m...................."'", 6, Sunwnary: 6.1 Total Exfiltration and Storage, O=E+S ..,......................,...., 6.2 Percentage of Required Quality, MS=100*(O/R) ............m.. 6,3 Equivalent Inches over the site (Excl. Lake Area)....,.......... 6.4 Volume Exfiltration per SFWMD computation..,......,........... OR........ Prinred: lllO8/0~ Project No,: 06604 % of Site , 0.0 sf 0.00% , 0.0 sf 0,00% , 115168.0 sf 35.72% , 11Sm.0 sf 36.84% , 88486.0 sf 27.44% , 322431.0 sf 100,00% , 207263,0 sf , 11sm.0 sf , 57,3 % 26869,3 cf , 38495.2 cf 38495.2 cf , 13434.63 cf 10,60 Acln ==>1 1.140E-Q3 , 5.00 fl , 3.00 fl , 0.00 fl , 3.00 fl , 19n.00 fl , 121704,12 cflhr , 73022.47 cflhr , 0,00 cflhr , 194726,59 cflhr , 2.00 fl , 0.00 fl , 3.14 sf , 2137,00 fl , 6713.58 cf 15.00 sf 5,93 sf 11722.04 cf 0.00 fl 0.00 cf 18435,62 cf " 213162.2 cf " 663.74 % > 7.93 in. > 58.21 Ac.ln. > 211312.3 cf 0:\0'\05504\05'04 exfi1tndc totlll.qpw 612 AREA OF PIPE ABOVE WATER 3,142 fully above water 1 ,571 % submerged o SUBMERGED area of pipe # - 6- I LOCATION I DE PT H (feet) SOIL DESCRIPTION II Y)) RA U L I (':~~~,I I CONDUCTIVITY' (cfs/ft2 per foot of Head Induced) 1.99 xlO-3 BHP-l 0- 10,0 Brown to Light Brown Sand I Clrllll!1dwater Depth: 7,0 feet below existing grade < l LOCATION I (feet) DESCRIPTION 2 II (cfs/ft per foot I of Head Induced) I ! BHP-2 0-10,0 Brown to Light Brown Sand 4.46x 1 0-4 I I I DEPTH SOIL I1YDRAlfUC i CO~DUCTI\'ITY I (jround'vvater Depth: 8.0 feet below existing grade LOCATION SOIL DESCRIPTION HYDRAULIC l CONDUCTIVITY !i I (cfs/ft2 per foot . . of Head Induced) 1 9,9Ixl(f" I DEPTH (feet) ,.,. ~___________l______.m___L_ BfII~~3~ro-=]()_,-O_n- T 'l3rown to Light Brown Sand I (jroundwatcr Depth: 8,0 feet below existing grade Avq::: //~ y/o ,-3 t.6e:-:.--:J //'7' (0LC?{/~/7ctY.s ~,astCuast COlIJlllunitirs I a RRA File \0, 6611-(l~-331 'I irr'ra, IlIl, /Unt ~ PR \PPLICA TION CONFERENCE REV. vv FORM Date 4- / 7 - 0 ~ Attending as Applicant Phone Time Started II: ()O KIM ~, CUTI't<J Time Finished Fax Applicant Must Initial for Receipt of n / FJ ~ Art in Public Places Ordinance 05-060~ and Art Program Info Sheet: ~ Proposed Project Information Proposed Project Name and t4Ull1 &V€. (NIUb2. ~ p~) TypelUse cStnmI ~~ I/-tvU Site Location (Address if Available) Site PCN Existing Zoning Proposed Zoning Existing Land Use.Density Proposed Land Use/Density / Vacant Anticipated Submittal Date Notes and Comments Lot Area Lot Frontage Lot Depth Setback Height Parking Requirements or hnprovements Landscaping/Buffering Non-conforming Use or Change in Use Other Zoning Changes Required Hazardous Material Notes/Comments/Recommendations IJ.JC ~CA-rvr 1$ /N~-ztJ IN IlUJt>IF/I/~ - I J.W l)6;}/rlG /$ ~ ~ ~ # ~ 2..s ~ 'Ii Z.3 0'. /HI ~ ~~.s f VIOl) 1:Jc1Z,S. ~ tJlfIll':J J()N~ ~ ~ ~~ (rJ 3. TJ.Wi. ~e1M/7 I~ M...$r) C6-1vt,~~ ~,(j-(p T1Je ~r ~ WI'T"}.>f JI- tH-P PUf&Al> IAl rJJC f#Uv60,4f( 'f'1hf-"r ~ A<Un</ -'W~ tI~-HCt,(i, I //) etVIet2- ()~84lJ n.tfJ,ol.1J..6 ~ to:>P. I9rnvAI'€ IJ,Usld?- I.!S )'tJ ~ UJI rH- ~€~.!I ~ 17-fE, ~/IbIUf& (}F ~~..v ~~. ~1IJ1Irt4.- ~lAf?llId.J rJI€ /~ ~A-1Z:tJ 1()f71-f' 11i€- ~U(p. ~r ~ INlIo~'" ~ bF rDo"(7 J)/J ~ M/J/-6)4.. - VS - IUII4CY2- ~PIc+n1J</J ~T1?Uk 4Md ~~. Ip1>/~ /P 1'1J<<: Sf ~ ~~ ~ 71Ie: 5'% ~) ~ nIe PlUCe55 W8tJt,/) ~ II-- M/NM- ~r:=t0ff1(}.IU ~ .4u.bI6Cr- "fl) 'r/.kZ A1tr' IAI /JaI/xi e.. ,~ ~/A/1hfJ~ . NOTICE: The purpose of this conference shall be for staff and applicant to discuss overall community goals, objectives, policies and codes as related to the proposed development and to discuss site plan review procedures. Opinions expressed at the pre-application conference are not binding for formal review purposes. Additional staff comments may be forthcoming based on actual plans submitted for review. S:\Planning\Planning\Pre-App Form pp 1-3\Pre-application Form p2.doc ,,<",' ,I ~ ~ PRE-APPLICATION MEETING SIGN IN SHEET PLEASE PRINT MEETING DATE: TIME: ATTENDING FOR APPLICANT: NOTICE: The purpose of this conference shall be for the staff and appUcant to discuss overall community goals, objectives, poUcies and codes as related to the proposed development and to discuss site plan review procedures. Opinions expressed at the pre-appUcation conference are not binding for formal review purposes. Additional staff comments may be forthcoming based on actual lans submitted for review. City of Boynton Beach Attending for Applicant Attendin Staff LLLU vw~l\ Lctl':.A.-Y) R-Db~ ~Ll -lee ~~ S:\Plannlng\Plannlng\Pre-App Form pp t-3\Pre-appllcatlon Form p3.doc ,,~ .,e.,:.,:. . . . . . . . . . . . . . . ".':':.:. .... . . . . e e . . . . . " .~.. .... . ..... -. .... . . ' " ...... '" . ..v COo J:::.. . Oz ~o -.0' OJ i~ i I , "'" !-.......: i / , .![j:j. . ... . ": "":" ":" ' ...............".. . . ........'a1........._ . .. . .. . .. '" ........ . ........... ............ - . ~. · ......s.."'..~ · .. ',-'. .. '-:';','{rrl.:. .~."_..__ . · · · · · · · · · · · · · · · · · · 'a'.'_' . . . . . . .. . . . . . ~ . . . . . '-' . , . . .. . " . 'a'_' . . .. .. _ ... . . . . . . . . . . . . . . . . . . . . . . . . .... ..... '. . . . . .... -. o. . . . .... '. . . . . . . . . . .... ... . '1"."""''i':;...:.