Loading...
APPLICATION . " 1 . , . ., ~ ,60. ' .,:;:W SITE PLAN APPROVAL APPLICATION City of Boynt6n ~each, Florida Planning and Zoning Board ~ This application must be filled out completely and accurately and submitted in one (1) copy to the Planning Department. !nccmpl~te applications will not pe processed. Ple~se print legibly or type all information. I. GENERAL INFORMATION 1. project Name: r H l/ f( IE V .f ~ o/I/'J fA( I9REllo U5e..s , / # . 2. Date this application is accepted: (to be filled out by planning Dept.) 3. Applicant's name (person or business entity in whose ~ame, this application is made): C/-IURlE. Vf.S()AIJ: {()/v,S-T- Co . / Address: 9- 5//\/ W 1()4/1 (/ G E~ YA-;7;;"J...1 /? IZIYCh Phone: 'i 5 c2... ___-g 9 6 9 -~ 4. Agent's Name (person, if any, representing applicant): 9:?f- ~ L~ Addres s : tJ J / .A/ f.",V / () X::I'At/ E g /'Jj,/ /...7T~u .8 t?- IJ c h phone: '7 -5 :1.-, :f 96 ? s. property owner"s (or Trustee's) Name: ~ (}~~~~ -c; , ' Address: LS j:} oM IS Phone: ..$ n- /"A.. l: 6. Correspondence address (if different than applicant or agent)*: ", * This is the address to which all agendas, letters, and other materials will be mailed. Planning Dept. 1/89 ,. .0 ': ~ ., ~ ?aqe 2 7. What is applicant's interest in the premises affec~~~7 (owner, buyer, lessee, builder, developer, contract purchaser, etc.) 8. Street address or location of site: .s F y/tr ~ . {31'1 S/ A/JON 9. Legal description of site and property control #: ) ~ -r- I i-:2 8 hOe to( / 9 13 0 (/tIlE R,~ p/~ tr /(' 10. Intended use(s) of site: {lvtJR~/1 tJ U~IES ,,; 11. Developer or builder: (:/-Iu Rey f (~CNJ CC~ ..$/ 12. Architect: J~(.} R J..... M (.J f/77N . ;:'~: t;;'. 13. Landscape Architect: 14. site Planner: 15. Engineer: r j? I? 1. A/\ f1 ;'1'"17;,,_ ~ Nf?' 16. Surveyor: D'13 f? I e AI) ,< D /7'6: I?rt:)f?I?I.AIIE,I,l{~" 17. Traffic Engineer: 18. Has a site plan been previously approved by the City commission for this property? AI () i 19. Estimated construction costs of proposed improvements shown on this site plan: PSI 000 ." , , Planning Dept. 1/89 y Page 3 II. SITE DATA The following information must be filled out below and must appear, where applicable, on all six (6) copies of the site plan. 1. Land Use Category shown in the Comprehensive Plan .. 2. 3. Zoning District Area of Site ,11\ I JI ~ t acres /~ -f :j q , sg. ft. 4. Land Use -- Acreage Breakdown a. Residential, including surrounding lot area or grounds AI It! acres % of site b. Recreation Areas · ~acres % of site (excluding water area) , c. Water Area ,fI/t; acres % of site d. commercial ~/H acres % of site e. Industrial ~In acres % of site f. Public/Institutional ,r(fI acres % of site g. Public, private and rr Canal rights-of-way acres % of site h. other (specify) , ~/II acres % of site i. other (specify) //4; ~ ",' acres % of site j. Total area of site '.1 ( acres % of site * Including open space suitable for outdoor recreation, and having a minimum dimension of 50 ft. by 50 ft. .. 5. Surface Cover a. Ground floor building 5~/) sg.ft. 53 % of site area ("building footprint") b. Water area sg.ft. % of site c. Other impervious areas, including paved area of public & private streets, paved area of parking lots & driveways (ex- cluding landscaped areas), and sidewalks, patios, decks, and athletic courts. sg'. ft. % of site d. Total impervious area !q,l)1) 0 sg.ft. % of site e. Landscaped area :!J _ 9.:l 'i sg.ft. II.. 'I % of site inside of parking lots . , l (20 sg. ft. per interior parking space reguired- see Sec. 7.5-35(g) of Landscape Code) . Planning Dept. 1/89 q '.. . .. Page 4 f. Other landscaped areas, sq. ft. o. of site '0 excluding water area g. Other pervious areas, /11 jtJ including golf courses, natural areas, yards, and swales, but excluding water areas sq. ft. % of site ~ ~ ~ :).JI II, q h. Total pervious areas sq. ft. % of site i. Total area of site /5'9-2. f sq. ft. /tJ % of site . 6. Floor Area a. Residential sq. ft. b. Commercial/Office sq. ft. c. Industrial/Warehouse ,S'tje () sq. ft. d. Recreational sq. ft. e. Public/Institutional sq. ft. f. Other (specify) sq. ft. g. Other (specify) sq. ft. h. Total floor area . ~"'If tJ D sq. ft. 7. Number of Residential Dwelling Units a. Single-family detached dwelling units b. Duplex dwelling units c. Multi-Family (3 + attached dwelling units) (1) Efficiency dwelling units ( 2) 1 Bedroom dwelling units (3 ) 2 Bedroom dwelling units (4 ) 3+ Bedroom dwelling units d. Total multi-family dwelling units e. Total number of dwelling units 8. 9. Gross Density dwelling units per acre Maximum height of structures on site feet stories 10. Required off-street parking a. Calculation of required number of off-street parking spaces b. Off-street parking spaces provided on site plan /2 , -t- So c):::: I I . l Planning Dept. 1/89 ~tJ , ; ?ac;;c 9 IV. MISCELLANEOUS The following materials must be submitted in one (:: ~cpy: (check) 1. A check, payable to the City of Boynton Beach, a~ per the attached fee schedule. . 2. For projects that generate at least three th~u~and (3,000) vehicle trips per day or two hundred ar.d fifty. (250) single directional vehicle trips in a or-e (1) hour period, a traffic impact analysis must be submitted . 3. Any other engineering and/or technical data, as may be ' required by the Technical Review Board to determine compliance with the provisions of the city's Code of Ordinances. v. CERTIFICATION (I) (We) understand that this application and all papers and' I plans submitted herewith become a part of the permanent I records of the Planning and Zoning Board. (I) (We) hereby' I certify that the above statements and any statements ot showings in any papers or plans submitted herewith:are true.' to the best of (my) (our) knowledge and belief. This application will not be accepted unless signed according to, the instructions below. VI. Si or is owned by a corporation business entity. AUTHORIZATION OF AGENT , ~rQe-,{~-;(~d Agent (I) (We) hereby designate the ~ - ;l$~?d Date ~ ~ ;; y- 9~ Date . r) above signed person as (my) (ou in regard to this application. gnature of Own res) or Trustee, r Authorized Principal if property is owned by a corporation or other business entity. SPACE BELOW THIS LINE FOR OFFICE USE ONLY ~ .. ;;l..2- 9 () , Date Review Schedule: Date Received: Technical Review Board Planning & zoning Board Community Appearance Board City commission Stipulations of Final Approval: Date Date, Date Date .. Other Government Agencies/Persons to be contacted: Additional Remarks: 'jJJ Planninq Dent 1/89 ~ {tuR E I 1- S o)JS r :p.J(. oj , D Y"" ~u e Co..t~ ('''-e ;"'~""f; ere D" (j'J-, v- ("-1 t Ir~f P.~~-j.f [(lJ'\/) . )r. '0 (,.J.:; ? '^<t ;.)<' v ~ f"'). "\" I if { (( ~ j ~" r" ~ {..: fro ',0 /0 f- (I /, 1M ,JJ1'Yl, r r., ~ {. k '?I ' t- D'~LO- 1F 1 I. "J C -L~ 'L L (, J '^f ill- J::'. Co v v.'" v f' r "(I c\!. "[O,} 'f^ ''''' + "-:; (;, "M J.. d- C. r , ..J: t' . e [..... 'r" tF-1 o <--<-I'r'J €r ) I'{ ~ '" '1" F- ("-~".TJ., ; ". J Ie CO lie ...."..... t " 5 to '- ~\A. vv t. t- Q...... V t\ "l 0 I '\ " f \ ' J f.r (, .1.. r., __. , tv ~ .J -I ~ v~ .s S t) V\. (!, ' v...- A r I \.- ~ ''t-' c.... t l C:? VV -- ~ It. $ - tJ L... $ / " , , I C (fCAR E- Y 1- SoNs I .]:IJC, 0<. ESuf3 Jt+lJA-t-) J .. - - . I, : "3 A-PP+T:':o)Jlr-L- (>1tR.F-+)JfZ- .s p~~S A-GQ, /::::e~ (o.J.Jl/(.).CIO R. {/(S~ _. ,.._.:J.,_, P R*;ri.{-A~~ ~ , , . ... _ .u. . . .__ . ~ _ . i --~-., .-~-- ri - -~"'.-'------'--'--- - .-: ' II : ' "'.. -- - --------.. I, , ~ / BUILDING DEPARTMENT MEMORANDUM NO. 90-114 March 26, 1990 TO: Timothy Cannon, Interim City Planner FROM: Michael E. Haag, Zoning & Site Development Administrator RE: COURTESY COMMENTS FOR JOHN CHUREY & SONS SITE PLAN Upon review of the above mentioned project, the following list of comments have been provided as a courtesy with the applicant's full knowledge that there will be a full review made when the project's site plan is placed on a Technical Review Board agenda: a 1. All documents submitted for public record and prepared by a design professional shall show original raised seal (legible) and signature of the Florida registered design professional responsible for the drawings. 2. State, on the drainage plan drawing, that a maximum one-half inch (1/2') difference in elevation will be maintained at the entrance door to each tenant space from the paved parking area. Where ramps are required to maintain the handicapped accessibility show and identify the width, length, slope and type of ramp material. (Ramps without handrails require flared sides with a 1 to 12 slope.) Ramped entrance ways require a level platform at the base and the top of each ramp. Show and identify the width, length, type of material and elevation of the case and top level platform. Handicapped accessibility must conform with the Handicapped Code. 3. Parking area markings for a concete surface are required to be black in color for regular spaces and blue for handicapped spaces. (Correct double stripe detail drawing.) 4. Identify, on the site plan drawing, the north and west building setback dimension. 5. Identify, on the elevation view drawings, the color of the exterior walls and doors of the building. 6. Specify the overall height of the trees shown on the landscape plan drawing (minimum height 8'0"). 7. Specify the location and type of all ground cover landscape material. 8. A continuous visual barrier of hedge material is required to screen the on-site vehicle use area (along east property line and loading area facing south property line) from the abutting properties to the east and south. The required hedge material must be spaced a maximum of 24" on center and at installation be a minimum of 18" in height. 9. Where landscaping is required along abutting properties, a planting space (landscape strip) with a minimum width of two and one-half feet (2.5') is required. 10. A solid wall dumpster enclosure is required to have landscape screening consisiting of accent shrubs. 11. Identify, on the plans, the dimension of the required loading space (minimum size 12' wide by 35' long). In order to factilitate the permitting process, the following information should be included within your documents submitted to the Building Department for required permits: The structure must comply with Table 400 and 600 of the Standard Building Code, 1988 edition. /3 cc:Don Jaeger CHUREY.SDD MEMORANDUM Utilities #90-192 F RO~1 : Timothy Cannon, Acting Planning Director John A. Guidry, ~~ Director of utilities ~ TO: ,. DATE: ~1arch 26, 1990 SUBJECT: TRB Review - Churey & Sons - Site Plan We offer the following comments on this project: 1. The plans do not show the location of either water or sewer services to the building. Please show all mains, services, and utility easements. Specify piping materials to be used in all cases, and also meter size. 2. The site plan does not indicate the distance to the nearest fire hydrant. The City Code requires that all points on commercial buildings be within 200 feet of a fire hydrant. If the site does not appear to meet this requirement, a water main extension and fire hydrant will be required, and shall be shown on the plans, dlh bc: Peter Mazzella /L} MEMORANDUM TO: Mr. John Churey FROM: James J. Golden, Senior City Planner DATE: March 22, 1990 SUBJECT: Churey & Sons, Inc. - Site Plan . The following changes are recommended by the TRB to meet applicable code requirements and allow for the site to function in a safe and efficient manner: 1. Reduce the building length from 108 feet to 100 feet at the east end. 2. Relocate the loading zone adjacent to the east end of the building. 3. Relocate parking spaces #10 and #11 to the middle island. 4. Modify the on-site traffic flow to one-way with the ingress at the west and the egress at the east. 5. Convert parking space #9 to an angled parking space and move this space to the northeast corner to where the dumpster is shown. 6. Relocate the dumpster to the south side of parking space #9 and angle opening toward the southwest. 7. The drainage system must be redesigned to provide for pre-treatment of stormwater runoff in grassy swale or landscaped areas (see Article X-Parking Lots). six copies of the revised site plan incorporating the staff comments should be resubmitted to the Planning Department by April 12 for review by the TRB on April 19, 1990. Q... 11l , /.h-'~\. GOLDEN JJG:frb A:Churey be- , TO: MEMORANDUM POLICE # 90-030 Mr. James Golden FROM: Lt. Dale Hammack RE: Churey & Sons Construction Company DATE: March 22, 1990 As per our discussion at the Technical Review Board meeting of 22 March 1990, I am recommending the following: 1. 2. 3. 4. Stop sign and stop bar at the exit of the parking area. One way signs at entrance and Do Not Enter signs at exit. Comply with the Construction Security Ordinance (5-8G) Ey. T.et2,itJ/t. 71 u ;'cI;":i m"..wt"l:'o . Details of parking lot lighting and ~-l.~ll~wll~.cldng rot- lighting. I!fd~CkL DH/cm I~ ENGINEERING DEPAR'IMENr MEMO NO. 90-071 March 20, 1990 TO: J. Scott Miller City Manager . FRCM: Vincent A. Finizio Acting Assistant to too City Engineer RE: T .R.B. CarIrents Metal Building - John Churey & Sons Lots #1 and #2, Block 19, Bowers Park SU'bdi vision Earl H. Martin & Associates, Consulting Engineers In conformance with too City of Boynton Beach, Code of Ordinances, specifically Chapter 19, Article II, Section 19-17, "Site Plan Review and Approval", including Chapter 5, Article X, "Parking lot Regulations", the above referenced applicant shall provide too following infonnation, data and plan corrections: 1. Provide a parking lot lighting plan, depicting location of lighting standards includincj photarel:rics~ Article X, Section 5-l42(a) required "Lighting" and Section 5-142 (g) "Lighting Standards". Note: All parking lot lighting shall be photo-cell activated. Section 5-l42(g). " 2. S.E. 8th Avenue to be extended to the eastern limit of the public rights-of- way for Boynton Beach, Florida. Chapter'19, Section 19-17 (d). 3. Provide a "stop sign" at too nortooast ingress/egress approach. Section 5-142 (c) "Traffic Control" 4. Indicate on plans the location of raised continuous concrete' curbing. Section 5-142 (e) "CUrbing". 5. Stomwater drainage structures shall be located in grassed areas to facilitate the pretreabrent of stomwater'. Section 5-142 (f) "Drainage" and Section 5-l42(g) "Drainage Standards". 6. Provide drainage system construction details for proposed exfiltration trench. Section 5-142 (g) "Parking Lot Construction". 7. Provide a detail for construction of the paverrent area (ie. what type asphalt, how thick?) Section 5-142 (g) "Parking lot Construction Standards". 8. Clarify the intended use' of the striped area, situated along the east side of the building structure'. Chapter 19, Section 19-17 (k) "Technical Data". 9. Provide grassed swales within the public rights-of-way for the pretreatIrent of stomwater realized fran S. E. 8th Avenue.' Engineering Departrrent Standard No. A-80033. 10. Specify type of luminaire to be utilized for parking facility lighting. Section 5-142 (g) "Lighting Standards". ~A.L. Vincent A. Finizio 0-- VliF/ck cc: Jim Golden, Senior City Planner v }C;-