Loading...
CORRESPONDENCE The Citl} 01 &l}11t011 Reach DEVELOPMENT DEPARTMENT PLANNING AND ZONING DIVISON 100 E. Boynton Beach Boulevard P.O. Box 310 Boynton Beach, Florida 33425-0310 TEL: 561-742-6260 FAX: 561-742-6259 f llE &1'1. www.boynton-beach.org July 10, 2007 Mr. James A. Seifert Addison Properties 6107 S. Dixie Highway, Suite 5 West Palm Beach, FI 33405 Re: Boynton Lofts (MMSP 07-038) Dear Mr. Seifert: In response to your request dated April 13, 2007 for the administrative review and approval of the modifications proposed to the above-referenced approved site plan, depicting the following: . Modification of building and facades, including reduction in the number of floors and revised floorplans, removal of one floor of parking, elimination of office space and reduction in retail space, and relocation of trash facility (as depicted on the attached plan) . . Relocation of pool amenity, elimination of the drive entrance off of Federal Highway and related landscaping changes (as depicted on the attached plan) . Please be informed that the proposed changes on the revised date stamped 6/15/07 are "minorH as defined within the Development Regulations, Chapter 4 Si te Plan Review. project may continue to be processed by the Building Division permit application, subject to the following conditions: plan Land This as a 1. The applicant has provided a "staging areaH for the compactor containers for pick up as determined in a meeting held with James Siefert of Addison Properties 5/22/07. However no area has been provided for bulk trash or recyclables. This item may be addressed at the time of permitting. 2. Depict all utility easements and utility lines on the landscape plans so that we may determine which appurtenances, trees or shrubbery interfere with utilities. In general, palm trees will be the only tree species allowed within utility easements. Please correct at the time of permitting. A brief review at this time indicates that there will be no conflicts. . Page 2 July 10, 2007 3. All Conditions of Approval (COA's) from the Development Order (DO) dated 4/22/05 continue in force and shall be addressed prior to issuance of any permits. Please note that COA #8, regarding payment of the Capacity Reservation Fee, is past due. please remit $6,514.20 to the Utilities Department as soon as possible so as not to affect plan reviews. 4. Please note that changes or revisions to these plans may generate additional comments. Acceptance of these plans during the minor modification process does not ensure that additional comments may not be generated at permit review. Be advised that the proposed changes may require a modification to the building permit. Please contact me at (561) 742-6260 if you have additional questions. Sincerely, Planner Cc: Karen Main, Plan Review Analyst Laurinda Logan, Senior Engineer Kevin Hallahan, City Forester DEPARTMENT OF PUBLIC WORKS ENGINEERING DIVISION MEMORANDUM NO. 07-084 FROM: Michael W. Rumpf, Director, Planning and Zoning Laurinda Logan, P.E., Senior Engineer ~. .-- July 9, 2007 \ \ \ ' \ I Review Comments \ Minor Site Plan Modification - 3rd Review Boynton Lofts (fka East Side Apartments) File No. MMSP 07-038 TO: DATE: RE: The above referenced Site Plans, received on 6/21/07, were reviewed for Public Works, Engineering, and Utilities against the requirements outlined in the City of Boynton Beach Code of Ordinances, Engineering Design Handbook and the comments' letter dated 6/04/07. At this time we have no objection to the proposed modifications to the plans. Remaining comments may be handled at the time of permitting. Following are our responses to the 6/04/07 correspondence (with the appropriate references): 12. The applicant has provided a "staging area" for the compactor containers for pick up as determined in a meeting held with James Siefert of Addison Properties 5/22/07. However no area has been provided for bulk trash or recyclables. Revised comment. 13. Deficiency addressed - no further action required. 14. Deficiency addressed - no further action required. 15. Depict all utility easements and utility lines on the landscape plans so that we may determine which appurtenances, trees or shrubbery interfere with utilities. In general, palm trees will be the only tree species allowed within utility easements. Please correct. This item may be addressed at the time of permitting. A brief review at this time indicates that there will be no conflicts. 16. All comments requiring changes and/or corrections to the plans shall be reflected on all appropriate sheets. Neither the Landscape nor Civil plans reflect the changes to the Site plan. Please correct. Deficiency addressed - no further action required. 17. Please note that changes or revisions to these plans may generate additional comments. Standard comment - please leave in. 18. Please note in your response back to the applicant that all Conditions of Approval (COA's) from the Development Order (DO) dated 4/22/05 continue in force and shall be addressed prior to issuance of any permits. Please note that COA #8, regarding payment of the Capacity Reservation Fee, is past due. Please remit $6,514.20 to the Utilities Department as soon as possible so as not to affect plan reviews. Please leave this revised comment in. ... Dept. of Public Works, Engineering Division Memo No. 07-084 RE: Boynton Lofts - Minor Site Plan Modification - 3rd Review, MMSP 07-038 July 9, 2007 Page 2 Cc: Jeffrey R. Livergood, P.E., Director, Public Works Peter V. Mazzella, Deputy Utility Director, Utilities H. David Kelley, Jr., P.E. / P.S.M., City Engineer, Public Works/Engineering Glenda Hall, Forestry & Grounds Manager, Public Works/Forestry & Grounds Division Larry Quinn, Solid Waste Manager, Public Works/Solid Waste File S:\Engineering\Logan\TRC\MMSP 07-038 Boynton Lofts 3nd Review 070607.doc Page 1 of 1 Breese, Ed From: Brooks, Vivian Sent: Monday, July 09, 2007 4:01 PM To: Coale, Sherie Cc: Breese, Ed Subject: RE: East Side Lofts Sorry I didn't get back to you sooner. We've been a little crazy here. The applicant has addressed my comments satisfactorily. Thanks. Vivian L. Brooks Assistant Director Boynton Beach Community Redevelopment Agency 915 S. Federal Highway Boynton Beach, FL 33435 561-737 -3256 561-737-3258 FX brooksvi@ci.boynton-beach.fI.us From: Coale, Sherie Sent: Monday, July 09, 2007 3:24 PM To: Brooks, Vivian Subject: East Side Lofts Hi, I left a vm too. Just trying to find out if they've satisfied (or generated) more comments. Ed's trying to finish the minor mod. Tx 7/9/2007 Addison Properties CJf S,~.JI:l FbrrJd Inc -, f\ nr )-~.-fs IR ~ ~ ~n ~ ~'II I \ ~ \ '\', [', ...,. ". "-111: , " i i I ~ I i ! \ \ I\, JUN I 5 2007 W ' ' i e,.,I_ I I ., l____-!.....--c-'--.. ..'---- To: City of Boynton Beach Development Department Planning and Zoning Division 100 E. Boynton Beach Boulevard P.O. Box 310 Boynton Beach, Florida 33425-031 ( Re: Boynton Beach Loft apartments (MMSP 07-038) Minor site plan approval Date: June 15, 2007 Dear Mr. Breese: ~1}J We have revised our submittal package baHed on your comments and submit the following responses based on your comment letter dated June 4,2007 as follows: o We have changed these canopies tu metal as requested. ~ Windows have been recessed as l~qut::.;lt:lJ. ~ Metal canopies have been provided as requested on north and south elevations. vK Accent lighting has been added above the storefront windows of the retail space and above the stairway access dools. In addition, we have added small squares penetrating the stairway wall with m !tal inserts as requested. 5. We have added additiunal :.;tu\,;co aticents, lowered the paring header openings and added a metal canopy to addre.;s comment as requested. vtf Planter boxes at garage opening! pool are as shown on Sheet ASP-1 and l-1. The aforementioned planter box pia ,ting material has been listed on plant list. and changed to fishtail palms. Addi:ional Fishtail palms have been added in rear to replace Gumbo Limbo in ""tility e515em~nL V Additional architectural detail has bE~n added to South elevation of tower 2 and . wall opening has been closed as requested. @ Three of the Washingtonia palms Or! the northeast side of the building have been changed to Royal Palms. Debra Turner the landscape designer in her opinion tells that due to the natural design ttleme of the plantingl5 thi~ iti lh~ only area where Royals would be appropriate. On the south side of the building, space limitations prohibit plantjng~ of Roy;; Is far enough from the building. ~ Please see revised lighting plan for ~hanges- Recent revisions have a maximum of only 11.2 foot candles and the av!rages are closer to 1 foot candle realm. The average of the entire parking area i~, 1.96. va: Please see revised lighting plan as I)pen area parking lot light fixtures have been ,A1aced in correct location. ,)'1- !he color of the light fixtures as proposed are white. We have included cut sheets for pole mounted light fixtures with full cut-off fixtures in lieu of sag lenses. In addition, we have included wall rrount light fixture cut sheets as requested. 6107 S. Dixie Hwy., Ste 5, West Palm Bch., F133405 Phone: 561-255-4:~98 Fax: 661-337-9133 2;13 39t'd S3Il~3dO~dNOSlaat' 2;9138989199 2;E:2;13 L13132; IL13 1913 vV' "'v (.,.f.., t,.(, (...l" @ The changes as indicated for the garbage removal are as per our discussion . with Lsurinda Logan of the Public Works Dept. 1 The "Rollout space" is now indicatecl on the Landscape Plan. '4. The -Loading Zone" has been delinElated and striped as requested and shown on Sheet 3 of 12 of the Civil drawings. 1 . The utilities have been indicated on the Landscape plan as requested. 16 The Land&cape and Civil plan reflects the Architectural &ite plan as shown. . Comment noted. ~ Comment noted. 19. Below are notes and response to CI~ comments. North/ South Elevations: Per our discussion with Vivian Brooks of the eRA she was made aware cf the various color changes to the elevations to address the comment req Jesting "vertical bands of composition". In addition, per other comment:; that we have addressed for these elevations. We have added additional metal canopies, 8" build~out at storefront openings, decorat ve screen at stairs and holes for natural light above the stairway opening!. Stairway opening6: Decorati'/e screen at stair openings have been added as requested. 5' step back: We have added decorative metal canopies and an a" build~ out at storefront openings to address this comment as per our discussion with Vivian Brooks of the eRA. West elevation: Additional Awning added to the garage entrance as requested. The comments are similar to both building types and the corrections made were completed on all unit types and all building ::onfigurations. If you have any further qUA!;tinn!=i nr commants pla::l!;A c:nntAd this:; nffi~ At (5A1) 255-4398. E0 39~d S3Il~3dO~dNOSlaa~ (;908SBSI9S (;E:(;0 L00(;/L0/90 -, ~~NThN ~.!> ~ ~~D 60. $1 DE ~~ ~-rnl L. f'Alt.l'tJ'lG, @ 2 Ec ) ~"""a. ""'r (JI+ai:.T A$P - , - f9$Jc:rsI.u till. ClrAl Rrwa. (II~I"" fa,) - ~/r-t ~(V""'I;-c..) -~l> JFo~ ~~Ai.s.e I - ~Ae?"'I.1 ( 1Zt::ilq..,(, c. - ~ 1='1" ) ~ ~ 41"' IZ.f1ht. ~ fZ.f:I.A( L Fo.e. '? l>W l/f:::1!Ja I CtA..8~ . - ~VI4-12~ IllBiP ~~. - ~ IS 0'VC?e '11'ff. 4-" f1IE. ~ <MJ ~t:M.r~? - ~ ~ ~C4iS~/... nt.t~I4JI~ V .. 6lI.J nit. ~~ l!IIAJ~r. /" ----- - ~ &t4~ ~ c ~OM--n~ V- ~ ~nwt.WI~OV ~r 611>&. - .s~ ELEVAnc:nv;s TlrO P~t~1 ~Ck. V - AILGH ~ ~CH ~ ~J.Itj,.) ~ A-fl.nCM,.- l.ATlON t Et-" . -~~Vl':.U~~,~_ V-- T7~~_~~s,.,..,~. - W~ ftVSl_~~_~ V --~~ro~~~. -v-4ltJ~(t.l/.Hr.) -~ I<<JN. ~ I ~ Fe. 6F '1"'~:rr:. "~"r ........."",,..... _,"! ~~Soo ~ ~ 4,ItO ~~. -~,..~~..~",.~ ./ ~~ ~ ~"t:M-. ~(~ ~ r~ """1+. -V~4fP~~LI~ fbc.e:s ~ (.., ~ I V /" .p~~ ~ II4-/Ud, --;/No f::JCTAtl- (Jf ru.t. U~ p~ K t:"('io~n.... Lc4-1 ""VI~. -~~. ~ ItJ~~'r - . ~C1.(MIAI*"~. - ~~~. The CihJJlf BounYon Beach DEVELOPMENT DEPARTMENT PLANNING AND ZONING DIVISON 100 E. Boynton Beach Boulevard P.O. Box 310 Boynton Beach, Florida 33425-0310 TEL: 561-742-6260 FAX: 561-742-6259 ~ www.boynton-beach.org June 4, 2007 Mr. James A. Seifert Addison Properties 6107 S. Dixie Highway, Suite 5 West Palm Beach, Fl33405 Re: Boynton Lofts (MMSP 07-038) 2nd Review Dear Mr. Seifert: The City of Boynton Beach staff has reviewed the second set of revisions to your plans for the above-mentioned project. The following comments are being forwarded to you for your review and response: o On the east elevation of Tower 1, staff recommends the reversion to the metal canopies with supports affixed to the wall above the canopy structure, as originally approved, and which better conform with the design of the building. vi On the east elevation of Tower 1, staff recommends the indentation of the area encompassing all four (4) windows on each end tower of that fac;ade, to provide for recessed windows as originally approved and in keeping with the overall building design. The Design Guidelines call for windows to be recess a minimum distance of four (4) inches. Staff would be satisfied with the same design as originally approved for these locations. vi Staff recommends the addition of the same metal canopies noted in comment #1 above, on the retail windows of the north and south elevations of Tower 1. ~ On the side elevations of Tower 1, the open stairwells should have accent lighting to add V some architectural flair to this rather boxy component. Additionally, staff recommends the small square accents be utilized in conjunction with the stairwell, in such a fashion that they actually penetrate the wall to let light show through in an artistic manner. 5. On the west (rear) elevation of Tower 2, the first floor elevation is too blank/plain. Staff recommends addition of architectural treatments for the walls, and greater attention to the parking garage tunnel openings. o On the north side elevation of Tower 2, the pool area has direct view into the garage and parked vehicles. Staff recommends that planter boxes be incorporated in those openings and that the landscape plan depict plant material taller than hedge material along this fac;ade. Although the applicant's response indicates the inclusion ofthese planter boxes, they do not appear to be depicted on any ofthe drawings. Additionally, the new hedge material along the north side ofthe garage (MC) is not indicated on the Plant List. Lastly, canopy trees were eliminated along the west side of the pool due to utility locations. Staff recommends the . Page 2 June 4, 2007 replacement of those canopy trees eliminated, with dense/low growing palms, which can be planted in utility easements. ~ On the south side elevation of Tower 2, the walls are too plain and unadorned. Staff recommends addition of architectural treatments. It is unclear why there needs to be an opening on the first floor of the garage along this wall, especially in such close proximity to the garage opening out into the parking field between towers. - 8. Additional trees of a greater height against the mass ofthe buildings are needed around the east, north, and south sides of Tower 1 and the west and north sides of Tower 2. The applicant has amended the plan and calls for 28 Washingtonia Palms between 30-35 feet. Staff recommends a minimum of half of these trees be Royal Palms. V The light values depicted on the Photometries plan are too high, with hot spots as high as 22 foot-candles in the surface parking area, and 72 at the garage entrance. These figures are entirely too high. The overall average is supposed to be in the realm of one (1) foot candle, with no more than 50% below 0.5. Please revise accordingly. 0>. The Photometrics plan appears to have light fixtures located within parking stalls and drive aisles. vi The color ofthe poles and light fixtures were not provided. Additionally, sag lens will not be allowed, as all lenses and bulbs must be shielded. Lastly, no details were provided for the gooseneck light fixtures to be placed on the walls. 12. A meeting was held with James Seifert of Addison Properties 5/22/07 to discuss the change in site layout and its effect on solid waste storage and pickup. A staging area outside the building was to be provided for the dumpster containers to be staged for pickup. The area provided will not be able to be accessed for use by Solid Waste. The area will need to be angled to provide the required clear backup distances required (minimum 60-ft.) Additionally no area has been provided for bulk trash or recyclables. - 13. The Landscape plan does not reflect the addition of the "Rollout Space." Please correct using the final area determined from Comment #12. _ 14. Delineate and stripe a "Loading Area" (LDR, Chapter 2, Section 11.1); include a pavement message in yellow indicating "No Parking - Loading Zone". 15. Depict all utility easements and utility lines on the landscape plans so that we may determine which appurtenances, trees or shrubbery interfere with utilities. In general, palm trees will be the only tree species allowed within utility easements. Please correct. 16. All comments requiring changes and/or corrections to the plans shall be reflected on all appropriate sheets. Neither the Landscape nor Civil plan reflect the changes to the Site plan. lease correct. v1 lease note that changes or revisions to these plans may generate additional comments. Vi'). lease note in your response back that all Conditions of Approval (COA's) from the Development Order (DO) dated 4/22/05 continue in force and shall be addressed prior to issuance of any permits. 19. The CRA staffhas the following comments: A. Building 1 and 2- North and South Elevation ~ Create vertical bands of composition between building base, mid-section and roof. ~ Add a decorative screen at the staircase area, i.e., lattice work, wrought iron, etc. o Add a five-foot step back between the 2"' and 3" floor. # VIV{ . Page 3 June 4, 2007 B. Building 2 - North Elevation ~ Create vertical bands of composition between building base, mid-section and roof. v{ Add awnings at all openings on the first floor. C. Building 2 - West Elevation ~ Add awnings at entrances to garage. Please submit revised plans reflecting the changes discussed above to continue the review of your request through the process. Staff will be happy to meet with you to discuss any of these issues or any potential plan revisions prior to your re-submittal. Do not hesitate to contact me with any questions or if there is anything I can do to assist you. Ed Breese Principal Planner CC: Karen Main, Plan Review Analyst Laurinda Logan, Senior Engineer Vivian Brooks, CRA Planning Director Kevin Hallahan, City Forester j~~ \ '....... c.. ' '). ... CJ c\ .. . ......../'i( ;> ~v .~ 1'0 N :;., DEPARTMENT OF PUBLIC WORKS ENGINEERING DIVISION MEMORANDUM NO. 07-069 TO: Michael W. Rumpf, Director, Planning and Zoning FROM: Laurinda Logan, P.E., Senior Engineer ~--> \ ) j DATE: June 4, 2007 RE: Review Comments Minor Site Plan Modification - 2nd Review Boynton Lofts (fka East Side Apartments) File No. NWSP 07-037 The above referenced Site Plans, received on 5/30/07, were reviewed for Public Works, Engineering, and Utilities against the requirements outlined in the City of Boynton Beach Code of Ordinances. Please note in your response back to the applicant that all Conditions of Approval (COA's) from the Development Order (DO) dated 4/22/05 (one-year extension granted 7/07/06) continue in force and shall be addressed prior to issuance of any permits. We recommend that the applicant address these comments and submit revised plans for review prior to approval of this minor modification request. Following are our comments with the appropriate Code and Land Development Regulations (LDR) referenced. PUBLIC WORKS - SOLID WASTE 1. A meeting was held with James Siefert of Addison Properties 5/22/07 to discuss the change in site layout and its effect on solid waste storage and pickup. A staging area outside the building was to be provided for the dumpster containers to be staged for pickup. The area provided will not be able to be accessed for use by Solid Waste. The area will need to be angled to provide the required clear backup distances required (minimum 60-ft.) Additionally no area has been provided for bulk trash or recyclables. PUBLIC WORKS - FORESTRY & GROUNDS 2. The Landscape plan does not reflect the addition of the "Rollout Space." Please correct using the final area determined from Comment #1. PUBLIC WORKS - TRAFFIC 3. Delineate and stripe a "Loading Area" (LDR, Chapter 2, Section 11.J); include a pavement message in yellow indicating "No Parking - Loading Zone". ENGINEERING 4. All comments requiring changes and/or corrections to the plans shall be reflected on all appropriate sheets. Neither the Landscape nor Civil plan reflects the changes to the Site plan. Please correct. Dept. of Public Works, Engineering Division Memo No. 07-069 RE: Boynton Lofts - Minor Site Plan Modification - 2nd Review, MMSP 07-038 June 4, 2007 Page 2 5. Please note that changes or revIsions to these plans may generate additional comments. Acceptance of these plans during the minor site plan modification process does not ensure that additional comments may not be generated during permit review. UTILITIES 6. Depict all utility easements and utility lines on the landscape plans so that we may determine which appurtenances, trees or shrubbery interfere with utilities. In general, palm trees will be the only tree species allowed within utility easements. Please correct. Cc: Jeffrey R. Livergood, P.E., Director, Public Works Peter V. Mazzella, Deputy Utility Director, Utilities H. David Kelley, Jr., P.E.I P.S.M., City Engineer, Public Works/Engineering Glenda Hall, Forestry & Grounds Manager, Public Works/Forestry & Grounds Division Larry Quinn, Solid Waste Manager, Public Works/Solid Waste File S:\Engineering\ Memorandums\Memorandums 2007\07-069 LOGAN MMSP Boynton Lofts 2nd Review 060107.doc Date: Project No: Name: Location: Type of Project: Size of Site: Number of Units: Existing Land Use: Proposed Land Use: Existing Zoning: Proposed Zoning: Parking Required: Parking Provided: Developer: Architect: CRA Comments: Boy '1 Beach Community Redevelopment . ~ncy Project Review 6/4/07 2nd review MMSP 07-038 East Side Apartments 623 S. Federal Highway Mixed-Use 1.2 acres (52,498 sq. ft.) 48 (39.83 duJac) MU MU MUL MUL 89.5 90 Oliver Toll aT Development 110 Broward Blvd., #700 Ft. Lauderdale, FL 33301 954-784-3100 CES 954-783-0526 1. Building 1 and 2- North and South Elevation . Increase ratio of glazed area to wall area. Remove . Create vertical bands of composition between building base, mid-section and roof. Keep . Add awnings at all openings on the first floor. REMOVE . Add a decorative screen at the staircase area, i.e., lattice work, wrought iron, etc. Keep . Add a five foot step back between the 2nd and 3rd floor. Keep 2. Building 2 - East Elevation . Add architectural details at blank wall areas. Remove . Create vertical bands of composition between building base, mid-section and roof. Remove 3. Building 2 - North Elevation . Increase ratio of glazed area to wall area. Remove . Create vertical bands of composition between building base, mid-section and roof. Keep . Add awnings at all openings on the first floor. Keep . Add architectural details at blank wall areas. Remove 4. Building 2 - West Elevation . Add awnings at entrances to garage. Keep . Add architectural detail to areas of blank wall. Remove Addison Properties ,~: SCUdl F'CJIJ", h: To: City of Boynton Beach Develnpment Department Planning and Zoning Division 100 E. Boynton Beach Boulevard P.o. Box 310 Boynton Beach, Florida 33425-031(1 Re: Boynton Beach Loft apartments (MMSP 07-038) Minor site plan approval Date: May 25, 2007 Dear Mr. Breese: We have revised our submittal package baaed on your comments and submit the following responses based on your comment letter dated May 2. 2007 as follows: 1. We have calculated our parking based on 1/200 sq.ft. (see calculations on our soite plan> and h;;'lvc changec to retail from orfice space. 2. We have removed the additiona storage closets on the plans and have resubmitted for your review. 3. The variance list as listed on ASP-1 was part of the original submittal and we have followed its intent in the current design but have removed the variance list from our plane. 4. We have revised the square foo:ages for the retail spaces and have recalculated the parking reqUirements. 5. We have added additional doere. in the office spaces in order to access the rear of the building. 6. We have added notes to descrit-e the textul ~~ and components of the elevations. 7. We will submit the. cOlored elevations as part of our set for your review. 6. We have added the use of metal canopies to the plans but we feel the use of canvas awnings would better suit the design intend and ask staff to consider the use of CC1miaa awnings at th,~ locations shown. 9. BaSed on the structural design (,f this building recessing the windows as requested would not be possible.. However, additional banding and scoring have been added to enhance th! look. 10. We have added various bandin~ and stucco score lines to enhance the buildings elev~tion:!t to a levl;:l hi!~her than the original submittal. 11. We have added various bandin, and stucco score lines to enhance the buildings elevations to a level hi!~her than the original submittal. 12. We have added various bandin~ and stucco score lines to enhance the buildings elevations to a level hi!~her than the original submittal. 13. We have matched the .11oor plan window locations to the elevations. 10 39'v'd 6107 S. Dixie Hwy., Ste 5, West Palm Bch., FI 33405 Phone: 561-255-4:198 Fax: 561-337-9133 S3Il~3dO~dNOSlaa'v' 1908989199 Pl:L0 L00l/P1/90 14. We have added various band in, and stucco score lines to enhance the buildings elev3Ition$ to a level hi!:Jher than the original ~ubrnjtti31L 15. We have added planter boxes a': the pool area as requested. 16. We have added various bandin~ and stucco score lines to enhance the buildings elevations to a level hi!~her than the original submittal. In addition we left the opening in the south 91evation at the garage lever for aesthetic value. We havEl also added &tucco detailing alii phscing windows on thIs elevation disrupts the furniture (bed) placement in these units. 17 _ Wart fern replaced sod in this area. 18. Additional trees of greater height were added. 19. We have increased the paver area and kept the Medjool Palm per request. Please see land3cape plan. 20. Lighting plan has been revised per comments 21. Lighting plan was changed to ae commodate light poles. 22. Lighting specs are attached with resubmittal. 23. GDmment noted. 24. We have provided (2) trash rOCrl& to liiupport the trash need 01 each tower. Both trash rooms have roll-out type trash containers which the on-site maintance workers will move to the rear of the building to the designated 8'-0" x 8'~0. temporary trash storage area (plan ASP-1). As per our meeting with Laurinda Logan of the engineeri 19 department 25. No compactor is being u5ed on ':hls current design. Typical rolling 6 to 8 yard dumpsters are being utilized. 26. Site triangles adc;Jed to landscape plan. 27. Ficus planting was replaced wittl podocarpus. 28. Trees were moved away from dJive. 29. We have defined the loading ZOlle as requested. (see site plan) 30. utility easements have bean added to landscape plan. 31. Fire l1ydrant was added back to NW comer of property area. 32. Our plans have been updated ali requested. 33. The plans have been modified to incorporate the eRA staffs comments. We believe the open sti:lirway we have designed IS more enclosed than the original proposed stairway and ii3 in keeping with the original design. The comments are similar to both building types and the corrections made were completed on all unit types and all building configurations. If you have any further questions or comments plea~tl COlltact thIs Office at (561) 255-4398. 2:0 39'ii'd S3Il~3dO~dNOSlaa'ii' 2:908S8S19S v2::L0 L002:/vl/S0 DEVELOPMENT DEPARTMENT PLANNING AND ZONING DIVISON 100 E. Boynton Beach Boulevard P.O. Box 310 Boynton Beach, Florida 33425-0310 TEL: 561-742-6260 FAX: 561-742-6259 www.boynton-beach.org May 2, 2007 Mr. James A. Seifert Addison Properties 6107 S. Dixie Highway, Suite 5 West Palm Beach, FI 33405 Re: Boynton Lofts (MMSP 07-038) Dear Mr. Seifert: The City of Boynton Beach staff has reviewed the revisions to your plans for the above-mentioned project. The following comments are being forwarded to you for your review and response: / The retail parking is denoted on the plans as office space and is being calculated at one (1) parking space per 250 square feet of gross space. The appropriate calculation is 1/200 for retail space, which will require additional parking. ~ The closets depicted in various rooms on certain models, such as B, C, & G, will require those rooms to be treated as additional bedrooms in the permit plan review, which again, will require additional parking spaces. 0' Sheet ASP-1 denotes a variance list. Are any variances being requested? If so, this review will be upgraded to a Major Site Plan Modification. vv.: Sheet AB-1.1 depicts an incorrect square footage for Retail C. ~ There does not appear to be any rear doors for the retail spaces. What is the method for receiving deliveries? Staff recommends rear access to these spaces. It also is advisable to create entrances for customers from the parking garage. ~ The building elevations require labeling for various building components, the material of construction and color application. ~ Color elevations of all sides of all buildings are required. ~ On the east elevation of Tower 1, are the coverings over certain doors awnings of some nature? Staff recommends the reversion to the metal canopies with supports originally t::\ approved, and which better conform with the design of the building. LV On the east elevation of Tower 1, staff recommends the indentation ofthe area encompassing all four (4) windows on each end tower of that fayade, to provide for recessed windows as originally approved and in keeping with the overall building design. ~ On the east elevation of Tower 1, staff recommends that the small square accents originally ~~ approved in the center portion of the fayade be re-incorporated into the design. D The side elevations of Tower 1 are too plain and unadorned. Staff recommends addition of architectural treat ents \!1Jl{'n a.sgrealer articulation, scoring, etc. Staff also recommends the addition of the same metal canopies oted in comment #8 above, on the retail windows on the first floor and the inc USlOn ofthe square accents noted in comment #10 above. '. . Page 2 May 29,2007 @on the side elevations of Tower 1, the open stairwells should have accent lighting to add some architectural flair to this rather boxy component. Additionally, staff recommends the small square accents, noted in comment # 10 above, be utilized in conjunction with the stairwell, in such a fashion that they actually penetrate the wall to let light show through in an artistic manner. ~ The windows on the side elevations do not appear to match the floor plans ofthe individual _ . units. Please review and verify that they correspond. (G))n the west (rear) elevation of Tower 2, the first floor elevation is too blank/plain. Staff recommends addition of architectural treatments for the walls, and greater attention to the ~ng garage tunnel opening~ @on the north side elevation of Tower 2, the pool area has direct view into the garage and kPP "p(i.C(); ~ parked vehicles. Staff recommends that planter boxes be incorporated in those openings and srva-o >t< . ~at the landscape plan depict plant material taller than hedge material alon this fayade. ~n the south side elevation of Tower 2, th wa s are too plain and unadorne . Staff recommends addition of architectural treatments. It is unclear why there nee s to be an opening on the first floor ofthe garage along this wall, especially in such close proximity to the garage opening out into the parking field between towers. Additionally, in the same area, the comer of this portion of the building appears to setback 16 feet from the south property line, yet there are no openings, even though this appears to be a bedroom and balcony area, with opportunity to provide something other than a blank wall. !4-v ,}J I 1 @ According to the design guidelines, there should be no sod placed between the building and f}S1(fb< ~. ~ right-of-way. The sod should be replaced with landscape material ofthe same type being tI'? t . tilized in the planting scheme already in the same vicinity. ~ ~ 8 dditional trees of a greater height against the mass of the buildings are needed around the fOOt.- ~ ~'(east, north, and south sides of Tower 1 and the west and north sides of Tower 2. fJb-( fJ/J t ~. The paver area on the east side of Tower 1 needs to increase in order to comply with COA ".. c.. tI ~ . #54, creating a larger pedestrian / public gathering space, thereby meeting the intent of the r:')~ MU zoning district. Staff recommends the elimination of the planter island in the center of r~ the building and retaining the Medjool Palm in a tree grate amongst the pavers. 1"~ ~W The light values depicted on the Photometrics plan are too high, with hot spots as high as 22 ~o tf1 foot-candles in the surface parking area, and 72 at the garage entrance. The overall average is supposed to be in the realm of one (1) foot candle, with no more than 50% below 0.5. . Additionally, the foot-candles at the property line should be zero. Please revise accordingly. @The Photometrics plan appears to have light poles located within parking stalls and drive aisles. #f0J6 ec,~o:;:T22) ~o details were provided of the light pole or fixture, including height, color, and materials. .flJ6 S~ S#f~6:P.~!he Minor Site Plan Modification approval will be subject to approval of Site Plan Time ~ E' ..vfM'1' ~\1'r.1 xtenSlOn. - ~a:~. 2 . The solid waste staging area was moved from the northwest comer to the southwest comer of vr' \ the four-story tower. The northwest comer had allowed room for bulk trash and recycling as well as providing for off-street solid waste pickup and turn-around. None of these items were able to be located on the revised plan. Please clearly indicate on the plans how solid 0' waste storage and pickup will be handled. 25. COA #2 of the original approval required a detail of the interior of the compactor storage room be provided. This detail was not found in these plans. Please provide this detail with the revised minor modification plans. . Page 3 May 29,2007 11 . ...frfll'# . 26 Show sight triangles on the Landscape plans using a 20- ft sight triangle for the driveway onto ~- SE 4th Street. vi Per the LDR, Chapter 7.5, Article II, Section 5.C.2. Ficus species are not permitted. The Ficus hedge, now shown around the pool, was not specified on the Commission approved plans. Please replace with an acceptable hedge material. &:y Staff strongly recommends placing canopy trees far enough back from drive aisles to minimize the potential for vertical conflicts with high-profile vehicles. A Gumbo Limbo is specified adjacent to the apparent location of the solid waste storage area. ~. Delineate and stripe a "Loading Area" (LDR, Chapter 2, Section 11.J); include a pavement message in yellow indicating "No Parking - Loading Zone". ~ Depict all utility easements and utility lines on the landscape plans so that we may determine which appurtenances, trees or shrubbery interfere with utilities. Canopy trees (Gumbo Limbo) are proposed in the northwest comer of the property that conflict with the proposed utility easements there. In general, palm trees will be the only tree species allowed within utility easements. Please correct. ,)'1. Correspondence from Addison Properties dated 4/12/07, submitted with the revised plans, indicates that the fire hydrant proposed at northwest comer ofthe property is to be removed. However the LDR, Chapter 6, Article IV, Section 16 requires that all points on each building will be within 200 feet of an existing or proposed fire hydrant (COA #7). The plan shall meet this condition and will be checked at the time of utility permit review. ~ All comments requiring changes and/or corrections to the plans shall be reflected on all r: _ \ appropriate sheets. \0 The CRA staffhas the following comments: 1ft_lIP ' ~ flY A. Building 1 and 2- North and South Elevation o Increase ratio of glazed area to wall area. v' Create vertical bands of composition between building base, mid-section and roof. v!. Add awnings at all openings on the first floor. '@ Add a decorative screen at the staircase area, i.e., lattice work, wrought iron, etc. [:) Add a five-foot step back between the 2nd and 3rd floor. ~ B. Building 2 - East Elevation Add architectural details at blank wall areas. Create vertical bands of composition between building base, mid-section and roof. C. Building 2 - North Elevation V. Increase ratio of glazed area to wall area. vi' Create vertical bands of composition between building base, mid-section and roof. ~. Add awnings at all openings on the first floor. Q Add architectural details at blank wall areas. D. Building 2 - West Elevation Q Add awnings at entrances to garage. Q Add architectural detail to areas of blank wall. . Page 4 May 29,2007 Please submit revised plans reflecting the changes discussed above to continue the review of your request through the process. Staff will be happy to meet with you to discuss any ofthese issues or any potential plan revisions prior to your re-submittal. Do not hesitate to contact me with any questions or if there is anything I can do to assist you. Sincerely, Ed Breese Principal Planner CC: Karen Main, Plan Review Analyst Laurinda Logan, Senior Engineer Vivian Brooks, CRA Planning Director Date: Project No: Name: Location: Type of Project: Size of Site: Number of Units: Existing Land Use: Proposed Land Use: Existing Zoning: Proposed Zoning: Parking Required: Parking Provided: Developer: Architect: CRA Comments: Boynton Beach Community Redevelopment Agency Proj ect Review 5/2/07 MMSP 07-038 East Side Apartments 623 S. Federal Highway Mixed-Use 1.2 acres (52,498 sq. ft.) 48 (39.83 du/ac) MU MU MUL MUL 89.5 90 Oliver Toll aT Development 110 Broward Blvd., #700 Ft. Lauderdale, FL 33301 954-784-3100 CES 954-783-0526 1. Building 1 and 2- North and South Elevation . Increase ratio of glazed area to wall area. . Create vertical bands of composition between building base, mid-section and roof. . Add awnings at all openings on the first floor. . Add a decorative screen at the staircase area, i.e., lattice work, wrought iron, etc. . Add a five foot step back between the 2nd and 3rd floor. 2. Building 2 - East Elevation . Add architectural details at blank wall areas. . Create vertical bands of composition between building base, mid-section and roof. 3. Building 2 - North Elevation . Increase ratio of glazed area to wall area. . Create vertical bands of composition between building base, mid-section and roof. . Add awnings at all openings on the first floor. . Add architectural details at blank wall areas. 4. Building 2 - West Elevation . Add awnings at entrances to garage. . Add architectural detail to areas of blank wall. " DEPARTMENT OF PUBLIC WORKS ENGINEERING DIVISION MEMORANDUM NO. 07-054 TO: Michael W. Rumpf, Director, Planning and Zoning FROM: Laurinda Logan, P.E., Senior Engineer DATE: April 25, 2007 RE: Review Comments Minor Site Plan Modification -1st Review Boynton Lofts (fka East Side Apartments) File No. NWSP 07-037 The above referenced Site Plans, received on 4/18/07, were reviewed for Public Works, Engineering, and Utilities against the requirements outlined in the City of Boynton Beach Code of Ordinances. Please note in your response back to the applicant that all Conditions of Approval (COA's) from the Development Order (DO) dated 4/22/05 (one-year extension granted 7/07/06) continue in force and shall be addressed prior to issuance of any permits. We recommend that the applicant address these comments and submit revised plans for review prior to approval of this minor modification request. Following are our comments with the appropriate Code and Land Development Regulations (LDR) referenced. PUBLIC WORKS - SOLID WASTE 1. Correspondence from Addison Properties dated 4/12/07, submitted with the revised plans, indicates that the solid waste staging area was moved from the northwest corner to the southwest corner of the four-story tower. The northwest corner had allowed room for bulk trash and recycling as well as providing for off-street solid waste pickup and turn-around. None of these items were able to be located on the revised plan. Please clearly indicate on the plans how solid waste storage and pickup will be handled. 2. COA #2 from the DO issued 4/22/05 required a detail of the interior of the compactor storage room be included with the permit application package. This detail was not found in these plans. Please provide this detail with the revised minor modification plans. PUBLIC WORKS - FORESTRY & GROUNDS 3. Show sight triangles on the Landscape plans (LDR, Chapter 7.5, Article II, Section 5.H.) using a 20-ft sight triangle for the driveway onto SE 4th St. 4. Per the LDR, Chapter 7.5, Article II, Section 5.C.2. Ficus species are not permitted. The Ficus hedge, now shown around the pool, was not specified on the Commission approved plans. Please replace with an acceptable hedge material. 5. Staff strongly recommends placing canopy trees far enough back from drive aisles to minimize the potential for vertical conflicts with high-profile vehicles. A Gumbo Limbo is specified adjacent to the apparent location of the solid waste storage area (per the 4/13/07 correspondence from Addison Properties.) Dept. of Public Works, EngineeringDivision Memo No. 07-054 RE: Boynton Lofts (fka East Side Apartments) Minor Site Plan Modification - 1st Review, MMSP 07-038 April 26, 2007 Page 2 PUBLIC WORKS - TRAFFIC 6. Delineate and stripe a "Loading Area" (LDR, Chapter 2, Section 11.J); include a pavement message in yellow indicating "No Parking - Loading Zone". ENGINEERING 7. All comments requiring changes and/or corrections to the plans shall be reflected on all appropriate sheets. 8. Please note that changes or revIsions to these plans may generate additional comments. Acceptance of these plans during the minor site plan modification process does not ensure that additional comments may not be generated during permit review. UTI L1TI ES 9. Depict all utility easements and utility lines on the landscape plans so that we may determine which appurtenances, trees or shrubbery interfere with utilities. Canopy trees (Gumbo Limbo) are proposed in the northwest corner of the property that conflict with the proposed utility easements there. In general, palm trees will be the only tree species allowed within utility easements. Please correct. 10. Correspondence from Addison Properties dated 4/12/07, submitted with the revised plans, indicates that the fire hydrant proposed at northwest corner of the property is to be removed. However the LDR, Chapter 6, Article IV, Section 16 requires that all points on each building will be within 200 feet of an existing or proposed fire hydrant (COA #7.) The plan shall meet this condition and will be checked at the time of utility permit review. Cc: Jeffrey R. Livergood, P.E., Director, Public Works Peter V. Mazzella, Deputy Utility Director, Utilities H. David Kelley, Jr., P.E.I P.S.M., City Engineer, Public Works/Engineering Glenda Hall, Forestry & Grounds Manager, Public Works/Forestry & Grounds Division Larry Quinn, Solid Waste Manager, Public Works/Solid Waste File S:\Engineering\ Memorandums\Memorandums 2007\07-054 LOGAN MMSP Boynton Lofts (fka East Side Apts) 042507.doc Addison Properties ....~-~-l-+.--~----- -:-_......-J 00\ ~ A~R " 32007 t' PLAt~Nir,G j:,:W '1 IOt"'G DlPl I' J OfSCLllh FI='I.:la 1-1=. City of Boynton Beach Planning and Zoning Div. Ed Breese 100 E. Boynton Soh. Blvd. Boynton Bch., FL 33425 April 13,2007 Re: Boynton Beach Lofts Dear Mr. Ed Breese, Please accept the attached 4 (four) St~ts of plans as our submittal package for changes made regarding the Boynton Beach lofts projl~ct. The following is a brief description of changes made m. thosa plans; The front tower was lowered from a 6 story to a 5 story and the rear tower was lowered frorn CiI G liitOry to a 4 story. The 2nd floor parking was eliminated snd now all parking is located on the 181 floor. All office space was eliminated. I ne front entrance off of Federal Hwy. was eliminated. Please note that we met with the Fire Marshal regarding this change and he is in agreement with having the single entrance at the rear. Front elevation railings were changed to solid wall railings. The building steps back at the 2nd f1ool' on both the front and rear elevations in lieu of the 3rd floor as shown on previous drnwing:3. Some of the front elevation overhangs were removed and all rear elevation trellises were removed. The pool thal Wj;:I:;i Iuoi:lted on the 2..... nOor decK nas Deen relocated to the 1'" Moor NW corner of the property. The trash facility was moved from thE northwest corner of the property to the southwest corner of the property. Regarding the civil drawings the fire h"drant at the northwest comer of the property was eliminated due to the availability of an I~xisting hyrlrnnt 1 block south on SE 4th street. Th@ civil engineer was not previously awart! of this existing hydrant Please note landscape changes made due to the above related modifications. Thank you in advance for your consideration and interest. Should you have any questions or comments I may be reached at the following nllmber 561-255-4398. ~aJlas " sewer 6107 S. Dixie Hwy., Ste /', West Palm Sch., FJ 33405 Phone: 561-255-4398 Fa}(: 561-337-9133 113 39\;1d S3Il~3dO~dNOSlaa\;1 G9la8989199 vv:9la LlalaG/Gla/vla - PROJECT NAME: Boynton Lofts LOCATION: 623 S. Federal Hwy PCN: 08-43-45-28-07-003-0050 & 08-43-45-28-07-003-0060 I FILE NO.: MMSP 07-038 II TYPE OF APPLICATION: I AGENT/CONTACT PERSON: OWNER: James A. Seifert ADDRESS: Addision Properties of South Florida, Inc. FAX: ADDRESS: 6107 S. Dixie Hwy Suite 5 West PHONE: Palm Beach, FL 33405 FAX: 561-337-9133 PHONE: 561255-4398 SUBMITT AL / RESUBMITT AL 4/13/07 1 ST REVIEW COMMENTS DUE: PUBLIC NOTICE/ SIGNS 30 days / 10 days IP ARC: ~ ; . i TART MEETING: LEGAL AD PLANNING & DEVELOPMENT BOARD MEETING: COMMUNITY REDEVELOPMENT AGENCY BOARD CITY COMMISSION MEETING: COMMENTS: S:\Planning\SHARED\WP\PROJECTS\Boynton Lofts\MMSP 07-\2007 PROJECT TRACKING INFO.doc