Loading...
LEGAL APPROVAL ..' fJ1ie City of 'Boynton 'Beach 100 'E. 'l3oynton fJ3each. 'l3oufevartf P.D. 'l3o:{310 'l3oynton 13eacti, 'ffcrida 33425-031Q (407) 738-7490 ~~~ 'f..\U: (407) 738-7459 Pwnning'Departrrunt, City:Jia[[ Compft:{ 'We.st 'Wing september 3, 1991 Mr. Ed London southwest Triangle Television Corporation 50 W. Mashta Drive Key Biscayne, FL 33149 RE: southwest Triangle Television Corporation - Site Plan (Warehouse) Dear Mr. London: At the August 27, 1991 Technical Review Board meeting it was determined that the above-referenced request for site plan approval will have to be resubmitted. This determination was based on the number and type of comments generated by different City departments. The following Planning Department comments, as well as the attached comments from other departments are being provided as a courtesy to the applicant. A complete review will be conducted by the Technical Review Board once the revised plans have been submitted. You should address the attached comments in your next submittal in order to facilitate the review of your application. For your information, the next submission deadline is September 13, 1991 by 5:00 P.M, 1. A resubmittal fee of 5250 must be included with the revised application. (Fee Schedule Ord, No. 90-38) 2. Revise any page(s) of the site plan application which may change as a result of a modification to the layout of the site. (I have included a new application for this purpose) 3. Storm drainage catch basins are to be located in grassy swales or other landscaped areas. (Compl-ehensive Plan, Policy 1.11.7) 4, Add a graphic scale on all plans/drawings submitted, (Site Plan application, page 5) 5t me rica 's gateway to tfie (julfstream Mr. Ed London -2- Attachments cc: subject file chron. file a:swtv,l Sept, 3 I 1991 BUILDING DEPARTMENT MEMORANDUM NO. 91-330 JI.. u gu s t 2 9, 1 9 9 1 THRU: ~O: Christopher Cutro, Planning Director DOli Jaeger, BU1lding OfficialW~ Michael E. Haag, 20n1ng & sit~evelopment Administrator FEOM: RE: TRB Comments - August 27, 1991 Meeting SITE PLAN - SOUTHWEST TRIANGLE TELEVISION COMPANY WAREHOUSE ~pon review of the above mentioned project, the following list of comments have been provided as a courtesy with the applicant's knowledge that there will be a full review made when the project is placed on a future Technical Review Board agenda. 1. Show consistency on the arch1tectural and engineering plans in representing the locationr size and finish floor elevation of the building. -, 0:... specify within the general note section of Sheet A-I that all uses proposed for the building are subject to the requirements of the Boynton Beach Code of Ordinances, '< show and state on the site plan the required number of parking spaces consistent w:th the parking ratios specified within Sect:on 11 H !6 f (5) of Appendix-A zoning. To accommodate the various uses that have different parking space requirements and to be allowe~ to occupy the building, I recommend that after you re-layout your site to comply with the TEchnical Review Board comments, you provide as many as possible of the additional parking spaces that are shown on the prelininary site plan. 4. show on the site plan the following loading zone information: i. location (not obstructing traffic flow or parking spaces) ii. ~ize (loading zone 12' wide by 35' long and 14' clear unobstructed heightj iii, method of identification (pavement markings and/or signs) 5, Placement of dumpster enclosure within an easement will require written authorization from all authorized users of said easement. I recommend locating dumpster enclosure outside of the easement. Provide a detailed plan view and full section view drawing of the dumpster enclosure and pad, Identify the following dumpster enclosure information: i, typer size and color of material proposed for the sides of the enclosure ii, specify the size and type of all required vertical and horizontal structural material and components for the enclosure walls and associated pad iii, identify the overall width and length of the enclosure iv. show ten feet (10') clear minimum width of the enclosure opening, Clear opening width must be measured and shown from inside of gate and post material or meet the Public Works Department specifications for size of compactor enclosure. v. where gates are proposed, specify the method of hol~ing the enclosure ga"~}RrtkT~ and closed po s 1 t l~n .1\...c~~1 V LV SEP 4 PLANNING DEPT. \ To: Christopher cutro Re: southwest Triangle Television, Memo # 91-330 Page Two of Four 6. Specify on the elevation view drawings the overall height of the str1.lctur'2. 7, Specify on the plans the following address that has been assigned to the site: 1080 W. Industrial Avenue. 8, For tenant and project title signage, spec1fy and show on the elevation view drawing one (1) square foot of signage per one (1) foot of linear bUilding frontage. Also identify the colors proposed for the 8ignage. Painted wall signs are prohibited. 9. Include within the drawings a detailed elevation view drawing of the proposed site lighting pole and fixture. Show and specify the following pole and fixture data. i. specify that the fixture is photocell activated ii, state that the pole, pole base and fixture is designed consistent with the windload requirements specified within Chapter 12 of the Standard Building Code, 1988 Edition 1ii. specify the type of luminary (metal halide or high or low pressure sodium) iv. show the light contours and specify their foot candle light level v. specify, where applicable, shields to deter off-site glare vi, show the height of the pole and fixture matching the height specified on the photometric drawing vii. specify the depth the pole and/or pole base is placed below grade ii1. provide a detail drawing of the pole base showing and specifying the vertical and horizontal structural ma~erials and components, including the size and type of f3s:eners required to attact the pole to the base ix. show the distance from the grade to the top of the pole base 10, Show on the site plan a handicapped accessible walkway leading to the entrance of the bUilding from the public sidewalk, specify on the plans the following walkway data: i. type of material ii. texture of the finish iii. width lV. slope for the entire length v, location, height, material and configuration of handicapped handrail, where required 11. Show the location and identify the height of the handicapped parking signage (7 foot from grade to the bottom of the sign). 12. show on the plan the location, width, length and elevation of the level platform that is required at the entrance to each tenant space, When the door swings out, a 60" by 60" platform is required and the platform shall extend at least 24" beyond the latch side of the door. When the door swings in, a 36" deep by 60" wide platform is required, Specify the slope of the walkway or parking lot surface at the point where said surface abuts the level platform. 13. The outline, configuration and material shown and identified on the project drawing(s) submitted with the plan(s) for final sign-off shall match in every respect the colored drawing(s) approved by the city Commission during the approval process of the project. The color of each exterior To: Christopher cutro Re: southwest Triangle Television, Memo ~ 91-330 Page Th~ee of Four finish materlal shown on the final sign-off plans shall be identified by name, color number and manufacturers name which shall match in every respect with the color(s) shown on the drawing(s) approved by the City Commission. A manufacturer's color chart showing and identifying all approved cclor(s) shall be submitted with the plans for final sign-off, '2.4. Identify the quality specification for the hedge material. 1 r: ~.J. state on the plans that the landscape material will be irrigated with an automatic water supply system. Specify the water supply source. 16. Specify the type and delineate the location and bou~dary of the sod for the entire site. 17. A landscape area with a continuous visual barrier is required to screen on-site vehicle use areas from West Industrial Avenue, the public right-of-way abutting the west p~operty line. show the location and specify the following required visual barrier and landscape information on the plans: i, dime~sion the spacing of each tree within the landscape area (maximum spacing forty feet [40'] on center) ii. identify the specie of tree and size (Minimum height at planting: elght [8] feet) iii. dinension the spacing of each hedge plant material required to form the continuous visual barrier (maximum spacing twenty-four [24] inches on center) iv. st~te the specie of each hedge plant material v. state the size specifications for all hedge plant material (minimum height at planting eighteen [18] inches) Vl. specify the type and location of the landscape material proposed for the remainder of the landscape area vii. specify type and location of mulch material to ~e used and it's thickness when laid 18, A continuous visual barrier is required to screen the on-site vehicle use area from the property that is abutting your property to the north, south and east, show the location and specify the following required visual barrier information on the plans: i. dimenslon the width of each continuous landscape area/strip (minimum continuous width is 2'6") 11. dimension the spacing of each hedge plant material required to form the continuous visual barrier (maximum spacing twenty-four [24] inches on center) iii. state the specie of each hedge plant material iv. state the size specifications for all hedge plant material (minimum height at planting eighteen [18J inches) v. specify the type and location of the landscape material proposed for the remainder of the landscape area vi. specify type and location of mulch material to be used and it's thicknesE when laid To: Christopher cutro Re: Southwest Triangle Television, Memo #91-330 Page Four of Four 19. Show on the landscape plan the computations used to provide the required 50% native specie count for the total number of trees, hedge, ground cover and vine landscape material specified on the landscape plan. Identify the native specie plant material by providing a distinguishable symbol by each native plant specified on the plan. In order to facilitate the permitting process, the following information should be included within your documents submitted to the Building Department for required permits: 1. All work must comply with the Standard Building Code, 1988 Edition and all subsequent City adopted codes. 2. Regarding exits: Businesses with a storage occupancy classification require that two (2) exits be provided when the travel distance within the tenant space exceeds fifty (50) lineal feet. Businesses with a manufacturing occupancy classification require that two (2) exits be provided for each tenant space. Redesign the floor plan to comply with the minimum exit requirements specified in the Building Code. 3. Tenant Separation: Mixed occupancy separation requirements must comply with Chapter 4 of the Building Code. .~ ENGINEERING DEPARTMENT MEMORANDUM NO. 91-163CC August 27, 1991 TO: Christopher Cutro Director of Planning FROM: Vincent A. Finizio Administrative Coordinator of Engineering RE: TECHNICAL REVIEW BOARD COMMENTS SOUTHWEST TRIANGLE TELEVISION COMPANY WAREHOUSE COURTESY COMMENTS In accordance with the City of Boynton Beach, Florida, Code of Ordinances, specifically Chapter 19, Section 19-17, "Plan Requiredll, including Chapter 5, Article X, lIBoynton Beach Parking Lot Regulationsll, specifically Section 5-142, lIRequired Improvementsll, inclusive, the applicant for the above referenced project shall submit the following technical data, plan revisions and information: 1. Provide a photometric plan depicting maintained levels of illumination along pavement areas. Levels of illumination must comply with Section 5-142(a) and associated Appendix titled lIStandards and Specifications for Required Lighting". All parking facility lighting shall be photocell activated. Lighting standards shall withstand a lateral wind load of 110 MPH and shall be certified by the Design Engineer. Section 5-142(g) , lIParking Lot Construction Standards". 2. Provide internal directional arrows, including a stop bar necessary to compliment the indicated stop sign in accordance with Section 5-l42(c), "Required Traffic Control". 3. The Architectural plans and Engineering plans do not compliment one another regarding the placement of raised continuous concrete curbing. Please resolve all plan conflicts and include a standard detail for raised continuous concrete curbing which shall comply with the requirements set forth in Section 5-l42(g), "Raised Continuous Concrete Curbing" standards. Section 5-l42(e), "Required Curbing". 4. Place wheel stops at each parking stall which does not front a raised continuous concrete curb. Section 5-142(e), "Car Stops". 5. In accordance with Section 5-142(f), "Required Drainage" and Section 5-l42(g) , lIDrainage Standards"and Specifications", the stormwater inlet structure shall be located within grassed areas to facilitate pre-treatment of stormwater. Revise plans accordingly. 6. Provide a handicap striping detail which complies with the DCA's most recent edition of the Accessibility Requirements Manual. Provide a standard stall detail which complies with Section 5-l42(g) , lIParking Lot Striping Standards" and Section 5-142(1), "Parking Lot Stripingll. 7. Sidewalks shall continue thru the ingress/egress approach along Industrial Avenue and be a minimum thickness of 6 inches thru these areas. Sidewalks shall be so transitioned as to accomodate the circulation of handicap persons. The subject sidewalk shall be defined with a expansion/contraction control joint. Section 5-l42(g) , lISidewalk Standards". 8. Provide a swale detail depicting fully sodded swales along the rights-of-way of Industrial Avenue. Swales shall be fully sodded and irrigated. 9. Plans indicate a 26 ft. free back-up area. The City of Boynton Beach, Florida, Code of Ordinances, specifically Section 5-142 Appendix, requires a free back-up area of 27 ft. Revise plans accordingly. 10. Provide a guardrail detail for the guardrail sections which cross the existing ditch. 11. Provide splash pad for the outfall end of the drainage system that discharges into the existing ditch. ENGINEERING DEPARTMENT MEMORANDUM NO. 91-163CC con't. T.R.B. COMMENTS - SOUTHWEST TRIANGLE TELEVISION COMPANY WAREHOUSE 12. Provide water quality calculations. None provided with this submission. 13. Provide 3 year - 24 hour calculations for parking lot elevation verification. None were provided with this submission. 14. Only pipe size calculations were provided with this submission based on an assumed 2 ft. per second velocity. Provide documentation that required storage is provided in adjacent ditch paralleling West Industrial Avenue. 15. The applicant shall provide a cross section diagram of the property to indicate the grading of adjacent tracts and finished grades of the proposed site. \ . . \, . U~ A-==t-A--.~ ~ Vincent A. Finizio Administrative Coordinator of Engf eering u!?:~~L W. Richard Staudinger, P.E. Gee & Jenson Consulting Engineers WRS:VAF/ck cc: J. Scott Miller, City Manager MEMORANDUM Utilities No. 91-451 FROM: c~ris~ophe~- cutro 0, Plannlng Dlrector\ John A, Guidry, Utilitles Director TO: DATE: August 28, 1991 SUBJECT: southwest Triangle Television - T~chnical ~eview Eoard In lieu of approval, we offer the following comments on this project: 1, Indicate locations of fire hydrants, water meters, grease traps and sanltary services on site plans. Location of water meters in paved areas is not desirable. 2. Only those tree species approved by the utllity Department may be placed in utility easements, 3, Dumpster enclosures or structures of any kind are not permitted in utility easements. 4, Fire hydrants must be installed to within 200' of all pcints of the building, 5. New wa ter mair;.s 6" and larg~r shall be cleaned wi th scft-sided swab, prior to t.esting, two passes. please affix this note to the plans, 6. Double check valve assembly will be requlre1 on the fire service line. 7. water services with either end under pavement are to te of Type K copper, c.. ..., , Irrigatlon is not to be supplied by City water. 9, Provide 6" cleanouts on the sanitary services at the property line, 10. Sewer cleanouts are required at a maximum spacing of 75' on private sanitary sewer services. 11, Work to be in accordance with Cit.y of Boynton Beach Details and Criteria sheets. 12. Owner shall prOVide fire flow calculations and details of fire protection system. 13. Palm Beach County Health Department permits are required, 14. Show on the plan the exact location of the water main and forcemain along the east property line. Field location is advisable. Contact Mr. Brent Allen at 738-7460 for this service, These comments mayor may not apply to the final design and we reserve the right to revisit this project review after submission of a utility plan. Utility drawings are attached. Field verification is required, R13.Cf,1\1f.D Ibks b~ . Mike Kazunas f\\lG 29 ~~N~\:\.G oa'l. ,~ PUBLIC WORKS MEMORANDUM NO 91-111 TO: TAMBRI HEYDEN - SENIOR PLANNER FROM: ROBERT EICHORST - PUBLIC WORKS DIRECTOR DATE: AUGUST 23, 1991 SUBJ: SITE PLAN RE: SOUTHWEST TRIANGLE TELEVISION CO. WAREHOUSE A turn around must be provided for the sanitation vehicle dnd the dumpster enclosure dimensiolls must also be shown. RE : he \.:c: file FIRE DEPARTMENT MEMORANDUM NO, 91-214 WDC TO: PLANNING DEPARTMENT FROM: FIRE DEPARTMENT DATE: AUGUST 30, 1991 RE: TRB - PROJECT - SW TRIANGLE TV COMPANY THERE IS NO TURNAROUND AREA THAT WILL ACCOMMODATE A FIRE ENGINE. FIRE HYDRANTS SHALL BE PROVIDED TO CONFORM TO SUBDIVISION REQUIREMENTS, 4ftd;;,~' Cztz?-?dl< WILLIAM D. CAV NAUGH, FIRE DEPARTMENT TRB REPRESENTATIVE ,FIRE PREVENTION OFFICER I swtritv.wdc pg MEMORANDUM POLICE #91-076 TO: Tambri Heyden FROM: Lt. Dale S. Hammack DATE: August 30, 1991 RE: S.w. Triangle Television Co. As per our discussion at the Technical Review Board meeting of 22 August 1991, I am recommending the following: 1. Parking lot lighting to be photocell activated. (City Ord. #5-138) 2. Need details of building mounted security lights and activation system. (Public Safety) tlf)~~ Lt. Dale S. Hammack DSH/cgm RECEI~lED AUG 29 PLAN NlI~G DEPT.