Loading...
APPLICATION City Codes Accessed Via Website www.bovnton-beach.org i !: www.amlegal.com!boynton_beach_fl.usCITY OF BOYNTON BEACH, FLORIDA ~ ~J OCT - 4 2[(; PLANNING & ZONING DIVISION I r,__. ____..~__". .,~, SITE PLAN REVIEW APPLICATION FOR ( ':rW,I' . 'I": NEW SITE PLANS & MAJOR MODIFICATIONS TO EXISTING SITe PLAN' ", : . Has applicant attended a pre-application meeting? ~,Date Ji 5,,0 6 This application must be filled out completely, accurately and submitted as an original to the Planning and Zoning Division. TWELVE COMPLETE, sequentially numbered, ASSEMBLED AND STAPLED sets of plans including a recent survey and appropriate fee shall be submitted with the application for the initial process of the Site Plan Review procedure. AN INCOMPLETE SUBMITTAL WILL NOT BE PROCESSED. Please print legibly (in ink) or type all information. I. GENERAL INFORMATION r 1. Project Name: Nc'Rrf-t tA'~'f::tV\t ~tf~ ()f MWlC I N~ 2. Property Owner's (or Trustee's) Name: ' I "{'I' Address: r6'50 N Wt;RAL t\lfd-t~\f4y J .:EtJl#. tt?DYNr01J ~H\ '3/?Ll25 f (Zip Code) / Phone: '77Z-?/S--~ -Y'3~ Fax: 772 -.-y6~'5 .;2/0 ~ 3. Applicant's name (person or business entity in whose name this application is made): 7)~,"" ~nt2- f~ rz ;;,4",,(/1/ J(G:. / h '-kr~?~/j e S 7~ c . , , / r Address: /~Jo A/ /;~_.:../#j4'4.'-4'-' .#/~ I ;;:;"'#t~",~{, -p'?Y:sr- / . " (Zip Code) Phone: '772- '::2-1':::-= '"3 ")/3 ~ Fax: 7;7;2 - -;/C''7{'.-.:2( C S- 4. If contract purchaser, please attach contractfor sal~urchas~. Agen 's Name (person, If any, representing applicant): ~''r-r 'f.,tJ, war-K. f t:A;';....,......~ t:~ <, ~'-' c ',.... C .... Phone: -:772-';21''5--7''Y3,,?? ?~, s7i~./ r~ 5"7997 (Zip Code) Fax: '772 - YC3" 2/0 ~ Address: C:7S- JV >>~.-"-"1"'" 5. 6. What is applicant's interest in the premises affected? (owner, buyer, lessee, builder, developer, contract purchaser, etc.) ,/hv rt f2. r' 7. Street address of location of site: V'-Dl !'1J / VI/' ( L...l'1 S \\JA y f 8. Property Control #(PCN) C ~ - 4.?:> .~ 4 S - ')-.1- - u €;'- [100 -- G /3 () 9, Legal description of Sl.d: k( 1,?,..(jJ W~ tVjtv( /1t~ILU ^\ v-m::- {1ft1)}~c.f' 010 flLE /W- 1~f 6ff{~~ 6f~ (iiai cf'1U:f (tzar HJ ',.i\lW lt~ ~li'JJ1(JJ;( t(YU~f{-c(fiL~YA ~1) lJ-) Jj(/~J~l- J~/1~ 11 Q; UU? lltf- )(!6( )Dffd:(lljU1/~ 10. Intended use(s) of site: I/C:.cL~J //',/ J! r P 11. Architect: t1. t44{H c}\{} W-f{ I J~~ tf1~ 12. Landscape Architect: ,.., II t::t& t:~ wt tJ 13. Site Planner: t{. 12A'-(}.f66J!J ~y.' /tE~ U(11:12r-- 14. Engineer: 15. Surveyor: k4'c-../ <:~;/ ~rc/ , - / " 16. Traffic Engineer: 17. Has a site plan been previously approved by the City Commission for this property? /tv II. SITE PLAN The following information must be filled out below and must appear, where applicable, on all copies of the site plan. 1. Land Use Category shown in the Comprehensive Plan: _~tAif.124{ f:t:)lIlUV\ 2. Zoning District: (~4: _ . 3. Area of Site ., r.? Z,!p acres j 41 (:Vt sq. ft. 4. Land Use - Acrea'ge' Breakdown: a. Residential, including ~t4- acres N'A- % of site surrounding lot area of grounds b. Recreation Areas * ,r~ acres f1/4-- % of site (excluding water area) c. Water Area /11 A- acres ;VA-' % of site d, Commercial II ~2---&-' acres /a % of site / e. Industrial ;1;:4- acres jV1/f % of site f. Public/Institutional f1/v1- acres AM- % of site g, Public, Private and Canal rights-of-way /VA- acres /lI A-- % of site h. Other (specify) ;VA- acres ;rA-- % of site i. Other (specify) ./VA- acres /1/4- % of site 2 j, Total area of site _ ~- f:f-- acres 1- ;~ % of site *including open spacE:: suitable for outdoor recreation, and havit<g a minimum dimension of 50 ft, by 50 ft. 5. Surface Cover 0_/1 4 - f:; L-- acres I~ a. Ground floor building area ("building footprint") % of site b. y,j/.J- acres /Y~ Water area % of site c. Other impervious areas, including paved area of public & private streets, paved area of parking lots & driveways (excludinp landscaoed areas), and sidewalks, patios, decks, and athletic courts. tP I '1 E? acres ~ % of site d. ?~ Landscaped area I C 61-- acres / ~ % of site inside of parking lots (20 sq.ft, per interior parking space required - see Sec. 7,5-35(g) of Landscape Code). Total impervious area acres % of site e. f. k'l?- acres /j/4- Other landscaped areas, % of site g. Other pervious areas, including golf course, natural areas, yards, and swales, but excluding water areas /t/4- acres /1/'/1- % of site Total pervious areas /j/'A--' acres #/f' % of site Total area of site , ?JZ V acres / 17-0 % of site . h. i. 6. Floor Area a, Residential /!//r- sq. ft. b. Commercial/Office '3'1 c; 0 (j A-' sq, ft. c. I ndustrialfW arehouse ,i./4- sq. ft. d. Recreational A/fr sq, ft. e. Public/Institutional ,1/A- sq. ft. f, Other (specify) .11 /f- sq. ft. g. Other (specify) /I/~ sq, ft. h, Total floor area .3C-;'C;O t.,l/r sq. ft. 7. Number of Residential Dwellino Units a, b. c. (1 ) (2) (3) Single-family detached 1V/1- iY'/r' sq. ft. sq, ft. Duplex Multi-Family (3 + attached dwelling units) Efficiency 1. ff 1 Bedroom ~ 2 Bedroom . 'VA 'fr' I I dwelling units dwelling units dwelling units 3 (4) 3+ Bedroom 1/,k dwelling units d. Total multi-family 0//1- dwelling units e. Total number of dwelling units wit:.... 8, Gross Density (;11Att-welling units per acre 9. Maximum height of structures on site '3 t:::- / feet i- stories 10. Required off-street oarkino a. Calculation of required # of off-street parking spaces. cJffCE-c .lJ1p-:J;c--e-L- ) :;;:~'lc5~' SF: - ~ ..--(~ - ) :zc:-tD@ :!J/~()n <'r = Off-street parking spaces provided on site plan //) / {....r (.? /Z:-= /~ 91;. = = b. Calculation of required # of handicap parking spaces Number of handicap spaces provided on ite plan ..2- ?J-(!/.' = REPRESENTATIVE OF THE PROJECT MUST BE PRESENT AT ALL TECHNICAL REVIEW COMMITTEE, PLANNING AND DEVELOPMENT BOARD OR COMMUNITY REDEVELOPMENT AGENCY (CRA) AND CITY COMMISSION MEETINGS HELD TO REVIEW THIS PROJECT. 4 III. CERTIFICATION (I) (We) understand that this application and all papers and plans submitted herewith become a part of the permanent records of the Planning and Zoning Division (I) (We) hereby certify that the above statements and any statements or showings in any papers or plans submitted herewith are true to the best of (my) (our) knowledge and belief. This application will not be accepted unless signed according to the instructions below. '---- -- ~~ '", '- SIgnature of Owner(s) or Trustee, of Authorized Principal if property is owned by a corporation or other business entity. 9)~6/0(' Date . OR Signature of contract purchaser (if applicant) Date IV, AUTHORIZATION OF AGENT /cp-7;~ 0 Date Sig (I) (We) hereby designate the above-signed person as (my) (our) authorized agent in regard to this application. / f' C--..2~/1/'Y~~- ~ Signature of Owner(s) or Trustee, or Authorized Principal if property is owned by a corporation or other business entity, /OA~'G Date OR Signature of contract purchaser (if applicant) Date A REPRESENTATIVE MUST BE PRESENT AT ALL TECHNICAL REVIEW COMMITTEE, PLANNING AND DEVELOPMENT BOARD OR COMMUNITY REDEVELOPMENT AGENCY (CRA) AND CITY COMMISSION MEETINGS HELD TO REVIEW THIS PROJECT. 8 RIDER TO SITE PLAN APPLICATION The undersigned as applicant for Final Site Plan Approval does hereby acknowledge, represent and agree that all plans, specifications, drawings, engineering, and other data submitted with this application for review by the City of Boynton Beach shall be reviewed by the various boards, commissions, staff personnel and other parties designated, appointed or employed by the City of Boynton Beach, and any such party reviewing the same shall rely upon the accuracy thereof, and any change in any item submitted shall be deemed material and substantial. The undersigned hereby agrees that all plans, specifications, drawings, engineering and other data which may be approved by the City of Boynton Beach, or its boards, commissions, staff or designees shall be constructed in strict compliance with the form in which they are approved, and any change to the same shall be deemed material and shall place the applicant in violation of this application and all approvals and permits which may be granted. The applicant agrees to allow the City of Boynton Beach all rights and remedies as provided for by the applicable codes and ordinances of the City of Boynton Beach to bring any violation into compliance, and the applicant shall indemnify, reimburse and save the City of Boynton Beach harmless from any cost, expense, claim, liability or any action which may arise due to their enforcement of the same. READ, ACKNOWLEDGED AND AGREED TO this ~lftT day of SEP TEm S6"~ ~ ".~~~~ ~Plicant ,20~6 Witness Witness 9 CC :URRENCY REQUIREMENT NOTICE TO APPLICANTS FOR APPROVAL OF LAND DEVELOPMENT ORDERS OR PERMITS Please be advised that all applications for the following land development orders and permits which are submitted on or after June 1, 1990 will be subject to the City's Concurrency Management Ordinance, and cannot be approved unless public facilities (potable water, sanitary sewer, drainage, solid waste, recreation, park, and road facilities) would be available to serve the project, consistent with the levels of service which are adopted in the City's Comprehensive Plan: Building permit applications for the construction of improvements, which, in and by themselves, would create demand for public facilities. Applications for site plan approval. Applications for conditional use approval. Applications for subdivision master plan approval. Applications for preliminary plat approval. Applications for final plat approval. Applications for rezoning to planned zoning districts. Applications for revisions to any of the applications listed above, which would increase the demand for any public facility. Any other application, which, in and by itself, would establish the density or intensity of use of land, or a maximum density or intensity of use of land. Applications for development orders and permits submitted after February 1, 1990 and which generate more than 500 net vehicle trips per day, must comply with the Palm Beach County Traffic Performance Standards Ordinance, unless exempt from that ordinance. Please be advised, however, that the following applications will be exemot from the Concurrency Management Ordinance, pending final approval of this ordinance by the City Commission: Applications for the development of property which was platted on or after January 13, 1978 and either the final plat or the preliminary plat and Palm Beach County Health Department permit applications were submitted or approved prior to June 1, 1990, and the use of the property is consistent with the general use which was intended for the property at the time of platting. Applications for the development of property, which was platted prior to January 13, 1978, the area of the platted lots does not exceed 2 acres, and the proposed use would not generate more than 500 net vehicle trips per day. Applications for building permit, if a site plan or conditional use application was submitted prior to June 1, 1990 and subsequently approved and the site plan or conditional use has not expired. Applications for the development of property within an approved Development of Regional Impact, and which are consistent with the approved DRI. Applications for approval of final plats, if the preliminary plat and application for Palm Beach county Health Department permits for utilities have been submitted prior to June 1, 1990. Applications for revisions to previously approved development orders or permits, which do not increase the demand for any public facility, 10 Plea$e be advised that these exem ')n rules are tentative and will be subje 0 final approval by the City Commission. If you have any questiv.1S concerning the proposed Boynton Bl!:iach Concurrency Management Ordinance, please contact the Boynton Beach Planning &Zoning Division at (561) 742-6260. CHAPTER 4 SITE PLAN REVIEW Section 7. Submission Requirements. Each applicant shall submit to the Planning and Zoning Division the following plans and exhibits in the number of copies specified by the Planning and Zoning Division, together with a Site Plan Review application and a fee adopted by resolution by the City Commission. 12 ASSEMBLED COPIES REQUIRED A. Existina site characteristics map: A sealed survey, not older than six months, showing all adjacent ~ streets, aneys and driveways, 'a~d also illustrating: t 1. Existing natural features, including but not limited to lakes, trees and other vegetation and soils and topography. 2. Existing buildings, building elevations, other structures, including use, height, dimensions and setbacks, 3. Existing utility lines and all easements, 4. Existing elevations (corner, street and finished floor) B. Site develooment plan: 1. A scaled drawing clearly illustrating proposed buildings and other structures, and any existing buildings and structures, which are to be retained, including use, height, dimensions and setbacks. 2. Proposed off-street parking spaces, driveways and sidewalks, including location, dimensions and setbacks, traffic control markings and signage. 3. Proposed fences and walls, including location, dimensions, setbacks, height and material. 4. Proposed location of lighting on site. 5. Proposed dumpster location. C. Landscape plan: 1. A separate scaled drawing (at the same scale as the site development plan) prepared as required by state law clearly illustrating proposed trees, shrubs, grass and 2. Proposed berms, watercourses and other topographic features. 3. A notation on method of irrigation. Architectural plan: 1. A scaled drawing clearly illustrating proposed building floor plan and elevations, including 11 ~. height, exteric 'imensions, exterior color and materiat '.. ..><;'"" fA colored elevation drawing (not mounted) showing aU elevations of the building. (Thjs "1.1'<' -" sut>rnittaJ can be waived by the Planning and Zoning Director when not applicable.) , E. Tabular Summary Containina: 1. Total gross project area by acreage and square footage and net buildable land area in acres and square feet. 2. Total number of proposed residential units, including characteristics by number of bedrooms and bathrooms and gross square footage of each typical unit. 3. Proposed nonresidential floor type of use and total gross square footage. 4. Square footage and percentage distribution of the total project site, including areas proposed for landscaped open space, vehicular use areas, other paved areas, and building coverage and total coverage. 5. Number and ratio of required and provided off-street parking spaces and number of loading spaces, 6. Water bodies in acres and square feet. 7. Height of buildings, F. Drainaae plan: 1. A separate scaled drawing (at the same scale as the site development plan) showing elevations, flow arrows, proposed drainage structures, proposed treatment facilities, etc, 2. An engineer's certification in writing that drainage wit! conform with all rules, regulations, ~.",,~~...-:::'J;~~o::~>c ' . 1$-. ,Codes, etc,JnclucUog. but not limited to, Chapter 6, Article IV, Section 5 of these Land;, "Development Regulations. ;'l \ , \ i \ .'IJi......". \ -'. i , I., " I " i \' ' \, (-/ ; \ ~:; /,t) t ~ " . ,/ ~~! \ 1\ I", J.,\ \1' f( u' 12 1!2!:t! CONSLIlTING CIVIL ENGINEERS, SURVEYORS & MAPPERS CIVIL AGRICULTURAL WATER RESOURCES WATER & WASTEWATER TRANSPORTATION SURVEYING,,,, MAPPING GIS " Partners for Resu Its Value by Design" 20YO Palm Beach Lakes Blvd, Suite 600 West Palm Beach, FL 33409 (561) 684-3375 Fax' (561) 689-8531 www.lbfh.com Drainage Statement Subject: of Medicine, North General Center J. Laventure Renelien, M.D. PCN 08-43-45-22-08-000-0130 Description: A vacant 0.326 acre parcel bounded by N. Railroad Avenue on the west, Federal Highway on the east, NE 12th Avenue to the south, and NE 13th Avenue to the north in the City of Boynton Beach. Drainage Criteria: The drainage system will be designed utilizing onsite dry retention for water quality. The drainage system will be designed to meet the requirements of the City of Boynton Beach. 6 ,. ~~-~ ~\ N ~ ~ 1"1~;~~Nr--- n,_< ':N!~~: i]'PT O;~~ &7 ~~. ftL- ":Jef ey . Ren~u1t, P.E, No. 18001 OCT 0 4 2006 LBFH, Inc. No. 959 3550 S.W. Corporate Parkway Palm City, FL 34990 G:\jeffrey-g\Drainage Statement doc 10/20/05 " Dunworth Construction, Inc. 625 SW Salerno Rd. Stuart, Florida 34997 772-215-3438 (office) 772-463-2105 (fax) November 9, 2006 RE: Review Comment #25 Project: North General Center of Medicine PROJECT TIMELINE City Commission Meeting: January 2, 2007 Application for Building Permit: January 3, 2007 Start of Construction: February 15,2007 Set Water Meter for Construction: February 15,2007 Completion of Construction: October 21, 2007 Permanent Water Meter and Wastewater Connection: October 21,2007 APt ....lCATION SUBMITTAL CHECKLL f NEW SITE PLAN & MAJOR MODIFICATIONS TO EXISTING SITE PLAN Project Name: tJ~434~ z.. z. C)c::;j' ~tJ{)OI). !;Submittal Date: AJ~ ~ o,.1"-4~.~ /o/-1'ltJ6 Owne Ageny ~~. ~ Submittal Included - -- Original Application ~ Twelve complete assembled & stapled sets of plans signed & sealed . Current survey (signed & sealed) / . Site Plan .-/' . Landscape Plan / . Elevations /' . Paving, Grading & Drainage Plan . Floor Plans ~ Rider to Site Plan Application V Appropriate Fees t/ Owners of Record Consent Form Warranty Deed (Last Recorded) /j/ III- Copy of Purchase Contract jI/ /J- Agent Authorization (including name & address) ~ Traffic Study/Statement l//eet1 Colored Elevation Drawing Not Attached Public Art Form / S:\Planning\SHARED\WP\FORMS\Templates and fonns\New Site Plan Submittal Checklist.doc The City of Boynton Beach Ar/ ~ommission 129 East Ocean Avenue BoyntGil Beach, Florida 33435 PUBLIC ART INFORMATION FORM 56~ . . 42.6784 THIS APPLICATION MUST BE SUBMITTED ALONG WITH THR SITE PLAN APPLICATION / Project Name ~r ~ t:. er.:::. Project location ,L. , Jo'l J t.h. Company Name Company Address Company Phone Web site Contact Person ~ Phone -?77-'L.".-r - "3"Y"3 ~ <lc.;r "-s .;;~ ~__ ~ yc:. ~ 0 ~ Q.o ~ Project contact name jf;;~., "'-'<Y'~ Phone 777-'Zl~ J1rt: Email ........0 r::h: c--S"~ c: '1?~ YA.. ~ou ,~ ~ Project description (include the projects design/image intent, special features/amenities, special construction materials) a CJve,r 4Z Project markets to Cj'-- Art Location/s /~r~&s/ Cr'le..r @ h~'1rt? ArtLCL- Is the Art Location accessible to the public? Yes X No Developer/ ArchiteCtlde~ concept for art I' ~ "Zrn...o-",} 71 ,A-r~~'/e c Will artist be hired by developer ~ f (yes or no) If yes, artist resume must be sub nutted to Arts Commission for approval Call to Artists required through the Arts Commission Construction value for the project 1 % Public Art Fee 1 % = % budget for the Art elementls of the project 70% = Elect to pay public Art Fee in lieu of Public Art in Proiect Site plan date Estimated completion date Arts Commission meet date Date received ordinance with recommendations and guidelines ~ ,{~~'~ '~) &1 re.,-o,r~ 13 City of Boynton Beach Building Division Name of Project: RESIDENTIAL & COMMERCIAL PROPOSED BUILDING PROJECTS /L~ c;l2~~ / a,,~ /i/ >/d~r ~lL Type of Project (Residential/Commercial): C--- e> /'"'C i"~ ( Description (town homes, condos, single-family, etc.) etc. ) /. (off}fJt retail, warehouse, restaurant, office, ~e.--c(-cc!!. /' A ,t17'c<z- Number of Dwelling Units/Bays Square footage: "-:('990 ." (/ ) valuatiorf S-c:tJ,. &0 cJ Number of Buildings (estimated) Building Permit Application Submittal Prior to October 1, 20 ? (Yes or No) /Yu . ,.-;- ~ Proposed Construction Start Date ~~ c...&......r (:17 Name of Agent, /4r /)"'.., "-'6~ ~ ~ iJ ~~"V. r '-/i C~s ~ y{. "- Address: C:Z5' f~ _~-/.r~r"> 7?i. City/State/Zip Code: .5~~r;' I'~- 3)/997 Phone: 7/2--2/~?~3? (cell) 772-Z(S-- 3~ ~ Name of Owner: ~;~J :r;fJ~ &<. / F .L;/7/'/ 'r ~ 5/ ;;;;'L ~ Address: /,ro AI: 7'~~1 ;,GYI'II~/ l:~'I~t?~c<- "7;7Y3-S- City/State/Zip Code: ~'7-1 Ji'.... ?~c.~ ~ '53 "Y5 S #' I ( . I Phone: 71?-2r'Y'5Y3 Y' (cell) 77~-'21.>"" 3")/3'? Revised 9/15/05 10 TREASURE COAST ENGINEERING AND DEVELOPMENT, INC. DRAINAGE STATEMENT BOYNTON BEACH / NORTH GENERAL BUILDING Project Owner: United Medical Enterprises, Inc. Project Location: 131S-1317 N. Federal Hwy Engineer: Adam Heltemes, P.E., No. 59353 TCE Project No.: 06-23 Date: November 29, 2006 All stormwater facilities, design and maintenance shall meet the Boynton Beach's Land Use Code Requirements for stormwater management and South Florida Water Management District requirements. Specifically: Water Quality: Exfiltration system shall be used for water quality purposes. Exfiltration trenches shall be designed to treat first flush of rainfall runoff over impervious areas (2.5-Inches plus ~-Inch of dry pretreatment as necessary). Water Quantity and Flood Storage: The parking lot shall be design to receive stormwater and shall be lower than the finished floor elevation of the proposed building. Discharge shall connect to the existing Boynton Beach stormwater sewer system. Maintenance: The capacity of the stormwater management system shall be properly maintained. Methods of required maintenance may include vacuuming exfiltration systems, replacement of landscaped berms, the installation of silt screens or similar devices, and the installation of sod. If any portion of a stormwater system ceases to function as designed, the property lessee or occupant will remove, repair or replace that portion of a stormwater system. Materials: The drainage system shall be designed for long-life and ease of maintenance. Materials used in the system and construction methods shall meet American Society for Testing Materials (ASTM), American Association of State Highway Officials (AASHO) and current Florida Department of Transportation (FOOT) specifications. Drainage pipe shall be fitted with headwalls, endwalls, inlets and other appropriate terminating and intermediate structures. Site Design Elevations: I. Parking lots. Parking lots served by exfiltration trenches shall have a minimum elevation above the fivl>-year, one-hour flood stage in accordance with South Florida Water Management District Permit Information Manual, Volume IV. 2. Finished floor elevations. Finished first floor elevations of all buildings or structures shall not be lower than the higher ofthe following elevations: a. Flood stage elevations established by Boynton Beach; or b, Eighteen inches above the crown of the street on which the building(s) or structure(s) fronts_ Erosion and Sediment Control: Erosion and sediment shall be controlled during construction and operation as required by the Boynton Beach, South Florida Water Management District requirements and per Florida Department of Environmental National Pollution Elimination Discharge System requirements. FEMA Flood Plain Statement: As located in FIRM Community-Panel 1201960004C, the project is located in Zone C, defmed as "Areas of Minimal Flooding." ~ 1110 E. 7TH Street, Stuart, Florida 34996 ph. 772-221-3724 -ft. 772-221-3726 tcedevelopment@yahoo.com BPENo.26590 # /'J-=- Ifdp~ Nell~rnp.5 fl )2C,/c6 . MTP Graue, Inc. 12798 Forest Hill Boulevard, Suite 303 West Palm Beach, FL 33414-4704 Phone: (561) 795-0678 Telefax: (561) 795-0230 November 13, 2006 City of Boynton Beach 100 East Boynton Beach Boulevard Boynton Beach, Florida 33425 Re: North General Building Property Control Number 08-43-45-22-08-000-0130 To whon it may concern: There is a 3,990 square foot office building being proposed on the east side of US-l , north of Martin Luther King Jr. Boulevard. The site is curretly vacant and the building is proposed for 2,000 square feet of general office and 1,990 square feet of medical office. The project will be builtout in the year 2008. Per your request, this statement has been prepared to comply with the requirements of Palm Beach County Traffic Performance Standards (FPS) Article 12 of the Palm Beach County Unified Land Development Code. The trip generation characteristics of the development have been determined using daily and peak: hour trip generation rates and equations provided by Palm Beach County Traffic Division which are based on the Institute of Transportation Engineers, "Trip Generation Report", 7th Edition. Table 1 presents the trip generation characteristics of the development while Table 2 presents the trip generation rates/equations used in the study. As shown in Table 1, the traffic impact of the proposed development is less than 20 peak: hour trips. Therefore, based on Palm Beach County Traffic Performance Standards, the proposed development is insignificant, does not require a traffic study, and meets TPS requirements. Should you have any questions about this project, do not hesitate to give us a call at (561) 795-0678. ,,-~- " "- M'[lfJa M. Tticra, P.E. PTesid~nt It! I.~IG (; Florida Registration Number 44095 Attachments: Tables 1 and 2 C:lDocuments and SettingslMilylMy Docurnents\mtplNolth General Building Statanenl.wpd 13-Nov-Q6 North General Building Trip,Gen TABLE 1 TRIP GENERATION NORTH GENERAL BUILDING , '.", J;-;AMPeakl-\our ,;.')':; .' ::'. ,,pM P~al("'our 'co'., ;tai'id "USe. ,,,M\Qutit ..,DaiIY. .....:rota!e': ;ello" . ,;'Uut i.';;'; Hf6tal .. "10 '.. " ,'Olit ~" General Office 2,000 66 8 7 1 10 2 8 Medical Office 1 ,990 72 5 4 1 8 2 6 Total 138 13 1 1 2 18 4 14 Passer-By 5.00% (7) (1 ) (1) 0 (1 ) 0 (1 ) Net New External Trips 131 12 10 2 17 4 13 TABLE 2 TRIP GENERATION RATES AND EQUATIONS AM Peak Hour PM Peak Hour Land Uses ITE Code Daily Total In Out Total In Out General Office 710 (1) (2) 88% 12% (3) 17% 83% Medical Office 720 36,13 2.48 79% 21% (4) 27% 73% (1) Ln(T) = O.77Ln(x) +3.65 (2) Ln(T) = 0.80Ln(x) + 1.55 (3) Ln(T) = 0.74Ln(x) + 1.83 (4) Ln(T) = 0.93Ln(x) + 1.47 Independent Variable (x): 1.000 square feet of gross leasable area . MTP Group, Inc. 12798 Forest Hill Boulevard, Suite 303 Wellington Florida 33414 .... II MTP Group, Inc. 12798 Forest Hill Boulevard, Suite 303 West Palm Beach, FL 33414-4704 Phone: (561) 795-0678 Telefax: (561) 795-0230 November 13, 2006 City of Boynton Beach 100 East Boynton Beach Boulevard Boynton Beach, Florida 33425 Re: North General Building Property Control Number 08-43-45-22-08-000-0130 To whon it may concern: There is a 3,990 square foot office building being proposed on the east side of US-I , north of Martin Luther King Jr. Boulevard. The site is curretly vacant and the building is proposed for 2,000 square feet of general office and 1,990 square feet of medical office. The project will be builtout in the year 2008. Per your request, this statement has been prepared to comply with the requirements of Palm Beach County Traffic Performance Standards (I'PS) Article 12 of the Palm Beach County Unified Land Development Code. The trip generation characteristics of the development have been determined using daily and peak hour trip generation rates and equations provided by Palm Beach County Traffic Division which are based on the Institute of Transportation Engineers, "Trip Generation Report", 7th Edition. Table I presents the trip generation characteristics of the development while Table 2 presents the trip generation rates/equations used in the study. As shown in Table 1, the traffic impact of the proposed development is less than 20 peak hour trips. Therefore, based on Palm Beach County Traffic Performance Standards, the proposed development is insignificant, does not require a traffic study, and meets TPS requirements. Should you have any questions about this project, do not hesitate to give us a call at (561) 795-0678. ~ Sim~ere17,11 MTP fft ~f' Inc. (/---.1\ [,i :~ \.......-~ I;" ,W 'I, 1:/1 ?,/U6 Maria M. Tejera, P.E. Prr~sident Florida Registration Number 44095 Attachments: Tables 1 and 2 C:\Documents and SettingsIMilylMy Docurnents\rntplNorth GeueraI Building Statemefll.wpd 13-Nov-Q6 North General Building Trip.Gen TABLE 1 TRIP GENERATION NORTH GENERAL BUILDING .' '." , ,i " /,AM ,Peak HoiJ( "., '.' '"."., :"PMPeakBour, Ui'ldOse . . Amourit . ' ,,;Oailv Total ~";Iri, 'rOlit " ';'8[6tal.,' "In ,Oirt General Office 2,000 66 8 7 1 10 2 8 Medical Office 1,990 72 5 4 1 8 2 6 Total 138 13 11 2 18 4 14 Passer-By 5.00% (7) (1 ) (1 ) 0 (1 ) 0 (1 ) Net New External Trips 131 12 10 2 17 4 13 TABLE 2 TRIP GENERATION RATES AND EQUATIONS AM Peak Hour PM Peak Hour Land Uses ITE Code Daily Total In Out Total In Out General Office 710 (1) (2) 88% 12% (3) 17% 83% Medical Office 720 36,13 2.48 79% 21% (4) 27% 73% (1) In(T) = O.77Ln(x) +3,65 (2) In(T) = 0,80ln(x) + 1.55 (3) In(T) = 0.74ln(x) + 1.83 (4) In(T) = 0,93Ln(x) + 1.47 Independent Variable (x): 1,000 square feet of gross leasable area . MTP Group, Inc. 12798 Forest Hill Boulevard, Suite 303 Wellington, Florida 33414 The City of Boynton Beach DEVELOPMENT DEPARTMENT PLANNING AND ZONING DIVISON 100 E, Boynton Beach Boulevard P.O. Box 310 Boynton Beach, Florida 33425-0310 TEL: 561-742-6260 FAX: 561-742-6259 www,boynton-beach.org November 17, 2006 Mr. Masoud Atefi MSCE, Senior Traffic Engineer Palm Beach County Traffic Division Department of Engineering and Public Works 2300 N. Jog Road 3 rd Floor West Palm Beach, FL 33411-2745 Re:Traffic Statement: North General Center of Medicine Dear Mr. Atefi: The enclosed Traffic Statement, prepared by MTP Group, Inc. was recently received by Planning and Zoning for the above-referenced application. Please review the enclosed information for conformance with the County's Traffic Performance Standards Ordinance, and provide Tim Large, Building Code Administrator and me with your written response. If you have questions regarding this matter, please call me at (561) 742-6260. Sincerely, Michael W. Rumpf Director of Planning and Zoning MWR/SC S:\Planning\SHARED\WP\PROJECTS\North General Center of Medicine\Traffic #2.doc TREASURE COAST ENGINEERING AND DEVELOPMENT, INC DRAINAGE STATEMENT BOYNTON BEACH NORTH GENERAL BUILDING Project Owner: United Medical Enterprises, Inc. Project Location: 1315-1317 N. Federal Hwy Engineer: Adam Heltemes, P.E., No. 59353 TCE Project No.: 06-23 Date: November 29, 2006 All stormwater facilities, design and maintenance shall meet the Boynton Beach's Land Use Code Requirements for stormwater management and South Florida Water Management District requirements. Specifically: Water Quality: Exfiltration system shall be used for water quality purposes. Exfiltration trenches shall be designed to treat first flush of rainfall runoff over impervious areas (2.5-Inches plus 'h-Inch of dry pretreatment as necessary). Water Quantity and Flood Storage: The parking lot shall be design to receive stormwater and shall be lower than the finished floor elevation of the proposed building. Discharge shall connect to the existing Boynton Beach stormwater sewer system. Maintenance: The capacity of the stormwater management system shall be properly maintained. Methods of required maintenance may include vacuuming exfiltration systems, replacement of landscaped berms, the installation of silt screens or similar devices, and the installation of sod. If any portion of a stormwater system ceases to fimction as designed, the property lessee or occupant will remove, repair or replace that portion of a stormwater system. Materials: The drainage system shall be designed for long-life and ease of maintenance. Materials used in the system and construction methods shall meet American Society for Testing Materials (ASTM), American Association of State Highway Officials (AASHO) and current Florida Department of Transportation (FOOT) specifications. Drainage pipe shall be fitted with headwalls, endwalls, inlets and other appropriate terminating and intermediate structures. Site Desi!U1 Elevations: I. Parking lots. Parking lots served by exfiltration trenches shall have a minimum elevation above the fiv~year, one-hour flood stage in accordance with South Florida Water Management District Permit Information Manual, Volume IV. 2. Finished floor elevations. Finished first floor elevations of all buildings or structures shall not be lower than the higher of the following elevations: a. Flood stage elevations established by Boynton Beach; or b. Eighteen inches above the crown of the street on which the building(s) or structure(s) fronts. Erosion and Sediment Control: Erosion and sediment shall be controlled during construction and operation as required by the Boynton Beach, South Florida Water Management District requirements and per Florida Department of Environmental National Pollution Elimination Discharge System requirements. FEMA Flood Plain Statement: As located in FIRM Community-Panel 120 I 960004C, the project is located in Zone C, defined as "Areas of Minimal Flooding." 1110 E. 7m Street, Stuart, Florida 34996 ph. 772-221-3724 -ft. 772-221-3726 tcedevelopment@yahoo.com BPE No. 26590 I . ~lF- ;ftltt ~ f4f? (f-f~.5 /1/24/CJ6 PRB-~\PPLICATION CONFERENCE REVL... # FORM Date -B I L ( ! C b Time Started ~ ' c:) O. Time Finished . '2:> : Q () Attending as Applicant JG(u;J R:ArNj:F rljt.i...t:l t-t- }: JC (lAJ IG f-) ~~- Phone 3c9. 4- t)[P ~ ax Applicant Must Initial for Receipt of Art in Public Places Ordinance 05-060_ and Art Program Info Sheet: Proposed Project Information Proposed Project Name and Pro p t) ~ d Type/Use d; e a--I 0 -F-; L e Site Location (Address if Available) ~ Site PCN Existing Zoning f!..:- 4- Existing Land Use.Density Anticipated Submittal Date d Proposed Zoning Proposed Land UselDensity / Vacant Lot Area ILf, /77 S+ Lot Frontage J 7 ~ .-.-YC\ C) I Lot Depth < 100/ Setback v~rlo6UJ C!..ovvt-n?-tr-i ~.-Al dl'~+ri e-t d W rLOt~ Height Parking Requirements or Improvements 1..:(,\.: u4/1 CLNa,LR... J I ~ 'S..oCLce ~ pra.aG~ d ~ I' Landscaping/Buffering Non-conforming Use or Change in Use Other Zoning Changes Required Hazardous Material Notes and Comments h r --M---t') A.J +- t).ilc; ^'~ ~ 01 . J 'l ,u I~ I (,' ~-+ '- / Q. r tAt" 'LQ. prt:'i US So J hu. + (\.c W 01 be.., t::; Vl-ppcsr+e d dUu.. -h--. rc fl d w; ~: tJ tj ~ NOTICE: The purpose of this conference shall be for staff and applicant to discuss overall community go~ls, objectives, policies and codes as related to the proposed development and to discuss site plan review procedures. Opinions expressed at the pre-application conference are not binding for formal review purposes. Additional staff comments may be forthcoming based on actual plans submitted for review. :'\.- ':;S'?--)( '7 (/ h ld~ ' S:\Planning\Planning\Pre-App Form pp 1-3\Pre-application Form p2.doc , PRE-APPLICATION MEETING SIGN IN SHEET PLEASE PRINT MEETING DATE: TIME: ATTENDING FOR APPLICANT: NOTICE: The purpose of this conference shall be for the staff and applicant to discuss overall community goals, objectives, policies and codes as related to the proposed development and to discuss site plan review procedures. Opinions expressed at the pre-application conference are not binding for formal review purposes. Additional staff comments may be forthcoming based on actual lans submitted for review. City of Boynton Beach Attending for Applicant ,Attendin Staff bJ~ i<a+lu ZarfUr S:\Planning\Plannlng\Pre-App Form pp 1-3\Pre-appllcation Form p3.doc Time and Date of Meeting ~ % 2 ~~rJ} ~ ~ 1. Phone: .3lo 1 ~ ~ cr re3 Cto... 3:L ~ - 0 ct tf! 0 ~ - oCt3' HA VB YOU SPOKEN TO ANY STAFF MEMBER ABOUT THE PROJECT? Yes No (IF YES, HA VB THOSE STAFF MEMBERS BEEN SCHEDULED FOR THE PRE- APPLICATION MEETING? PRE-APPLICATION CONTACT QUESTIONS ~~ Applicant's Name: STAFF MEMBERS NAME: 2. LOCATION OF PROPERTY (CROSS STREETS/INTERSECTIONS) ) ~ <-.;. It- JU4 "" J.uC 3. WHAT/WOULD YOU LIKE TO DO? ~ ~'I--' NEW PROJECT r II --- BUILDING EXPANSION OR MODIFICATION CHANGE IN PRIOR USE? IS THE STRUCTURE CURRENTLY VACANT? VARIANCE TYPE: POOL OR SCREEN ENCLOSURE COMMERCIAL PROPERTY? RESIDENTIAL PROPERTY? INDUSTRIAL PROPERTY? DO YOU KNOW THE ZONING CODE DESIGNATION? /JQI4A~~ 4. TIME AND DATE PREFERRED 5. HOW MANY PEOPLE WILL BE AT THE PRE-APP MEETING? Note: Tell the person that someone from the Department will call them to confirm the meeting. ................................................................................., · Pre-application meetings should be scheduled for a minimum of one (1) hour time module, and should be scheduled no less than two (2) days prior to date/time of meeting, If urgency is sensed, discuss with Mike. · Meetin2S may be scheduled: Monday afternoons Tuesday all day Wednesday all day Thursday mornings Note: Mike is not available on Mondays between 11 :30 a.m. and 2:30 p,m. S:\Planning\Planning\Pre-App Fonn pp 1-3\Pre-application Fonn p I.doc , PRE ,- ~~ vd fkry ?PLICATION CONF~I FORM - Date 1.J../3<1'ime Started 6 . c) () Attending as Applicant Phone Time Finished Fax Applicant Must Initial for Receipt of Art in Public Places Ordinance 05-060_ and Art Program Info Sheet: Proposed Project Information Proposed Project Name and ",J 7 TypelUse fYl.€-a.r;. U--{ a+-{:..( '(!AZ-. .5 Site Location (Address if Available) Site PCN Existing Zoning Existing Land Use.Density Anticipated Submittal Date ~/d~ J Proposed Zoning Proposed Land Use/Density / Vacant Notes and Comments Lot Area Lot Frontage Lot Depth Setback Height Parking Requirements or Improvements Landscaping/Buffering cJ-.. Non-conforming Use or Change in Use Other Zoning Changes Required Hazardous Material S:\Planning\Planning\Pre-App Form pp 1-3\Pre-application Form p2.doc PRE-APPLICATION MEETING SIGN IN SHEET PLEASE PRINT MEETING DATE: TIME: ATTENDING FOR APPLICANT: N OTI CE: The purpose of this conference shall be for the staff and applicant to discuss overall community goals, objectives, policies and codes as related to the proposed development and to discuss site plan review procedures. Opinions expressed at the pre-application conference are not binding for formal review purposes. Additional staff comments may be forthcoming based on actual lans submitted for review. City of Boynton Beach Attending for Applicant Attendin Staff I . i, ! " j:'. 6 ~--esC ., // K >( <..J ;v cfCrttt cei-t-Lv- S:\Planning\Plannlng\Pre-App Form pp 1-3\Pre-application Form p3.doc ) ... I j~ ~ ~ Time and Date ofMeetittg ~~ ,Ill J ~~ e 3 Those~nding meet~ /' ' Dj~, PRE-APPLICATION CONTACT QUESTIONS L y- Phone: .3<< '1- 0 c, 'If () Applicant's Name: STAFF MEMBER ABOUT THE PROJECT? 2. ~ fr"; 3. WHAT WOULD YOU LIKE TO DO? NEW PROJECT BUILDING EXPANSION OR MODIFICATION CHANGE IN PRIOR USE? IS THE STRUCTURE CURRENTLY VACANT? VARIANCE TYPE: POOL OR SCREEN ENCLOSURE COMMERCIAL PROPERTY? RESIDENTIAL PROPERTY? ~USTRlALPROPERTY? DO YOU KNOW THE ZONING CODE DESIGNATION? 4. TIME AND DATE PREFERRED 5. HOW MANY PEOPLE WILL BE AT THE PRE-APP MEETING? Note: Tell the person that someone from the Department will call them to confirm the meeting. .................................................................................. · Pre-application meetings should be scheduled for a minimum of one (1) hour time module, and should be scheduled no less than two (2) days prior to date/time of meeting, Ifurgency is sensed, discuss with Mike, · Meetinfls may be scheduled: Monday afternoons Tuesday all day Wednesday all day Thursday mornings Note: Mike is not available on Mondays between 11:30 a,m. and 2:30 p,m. S:\Planning\Planning\Pre-App Form pp I-3\Pre-application Form p I.doc "[u. W~i^. f, ~ ~_~,,"~.:r ~ I . , ,Ill ~ J II _ , PRE PPLICA TION CONFERENCE REVl r FORM Date &./ ~ Attending as Applicant Phone Time Started 2> : J 0 K tav) 16 {}v>- rl-J 0/- Time Finished fYl tu-Icc L/ I' -btl.4.. Fax Applicant Must Initial for Receipt of Art in Public Places Ordinance 05-060_ and Art Program Info Sheet: Proposed Project Information Proposed Project Naple and TypelUse Vn. ~ (J / e ILl off-c'e L /0/ d <s _ Site Location (Address if Available) Site PCN Existing Zoning C!- - 4 Existing Land Use.Density Anticipated Submittal Date Proposed Zoning /V, ( t::.. Proposed Land Use/Density / Vacant Lot Area ILf (77 -s+ I Lot Frontage I 7 ? - C)-CC\ I Lot Depth <( ~ Setback li\.J-b C!OV~i'Ai Height Parking Requirements or Improvements Landscaping/Buffering Non-conforming Use or Change in Use Other Zoning Changes Required Hazardous Material Notes and Comments di/Jf-r: cJ- c v-U'lOt~1 NOTICE: The purpose of this conference shall be for staff and applicant to discuss overall community goals, objectives, policies and codes as related to the proposed development and to discuss site plan review procedures. Opinions expressed at the pre-application conference are not binding for formal review purposes. Additional staff comments may be forthcoming based on actual plans submitted for review. S:\Planning\Planning\Pre-App Form pp 1-3\Pre-application Form p2.doc ./ PRE-APPLICATION MEETING SIGN IN SHEET PLEASE PRINT MEETING DATE: TIME: ATTENDING FOR APPLICANT: N OTI CE: The purpose of this conference shall be for the staff and applicant to discuss overall community goals, objectives, policies and codes as related to the proposed development and to discuss site plan review procedures. Opinions expressed at the pre-application conference are not binding for formal review purposes. Additional staff comments may be forthcoming based on actual lans submitted for review. City of Boynton Beach Attending for Applicant X Attendin Staff rr;~ cf<.a:t-11/ ee/A-J ? e.+I e~ La..u n Hdu l-.cr- (f\ S:\Planning\Plannlng\Pre-App Form pp 1-3\Pre-appllcatlon Form p3.doc ... I. % 3O::E Time and Date of Meetingd/t.( Z3 (;) ~ a~eeting: . U- ~A~ PRE-APPLICATION CONTACT QUESTIONS Applicant's Name: 'fn.~d-d- Phone: ..3:?'-f. 0 ~ yo 1. HAVE YOU SPOKEN TO ANY STAFF MEMBER ABOUT THE PROJECT? Yes / No (IF YES, HAVE THOSE STAFF MEMBERS BEEN SCHEDULED FOR THE PRE- APPLICATION MEETING? STAFF MEMBERS NAME: !t-1Y' c:./t' ~ #t~ _ '-1(.-0' 2. LOCATION OF PROPERTY (CROSS STREETS/INTERSECTIONS) ~7Z:1.J <../~7 3. WHAT WOULD YOU LIKE TO DO? NEW PROJECT BUILDING EXPANSION OR MODIFICATION CHANGE IN PRIOR USE? IS THE STRUCTURE CURRENTLY VACANT? VARIANCE TYPE: POOL OR SCREEN ENCLOSURE COMMERCIAL PROPERTY? RESIDENTIAL PROPERTY? ~USTRlALPROPERTY? DO YOU KNOW THE ZONING CODE DESIGNATION? 4. TIME AND DATE PREFERRED 5. HOW MANY PEOPLE WILL BE AT THE PRE-APP MEETING? Note: Tell the person that someone from the Department will call them to confirm the meeting. .................................................................................. · Pre-application meetings should be scheduled for a minimum of one (1) hour time module, and should be scheduled no less than two (2) days prior to date/time of meeting, Ifurgency is sensed, discuss with Mike, · Meetimls may be scheduled: Monday afternoons Tuesday all day Wednesday all day Thursday mornings Note: Mike is not available on Mondays between II :30 a.m. and 2:30 p,Jn. S:\Planning\Planning\Pre-App Fonn pp 1-3\Pre-application Fonn p I.doc t PRl .PPLICA TION CONFERENCE REVl 1 FORM Date ~ - I 5 () [, Attending as Applicant Phone Time Started T2~,/ l7?( CZR.'1 Time Finished Fax Applicant Must Initial for Receipt of _ 1:;1' ~7 Art in Public Places Ordinance 05-06~ and Art Program Info Sheet~ Proposed Project Information Proposed Project Name and TypefUse Site Location (Address if Available) Site PCN Existing Zoning C - y Existing Land Use.Density Anticipated Submittal Date , Proposed Zoning N (c... Proposed Land Use/Density / Vacant Lot Area iLL l ~ll ~ Lot Frontage I f) t; Z C 0 Lot Depth -<-100' Setback UQ1?vv\ C~~-r..P C'1t<.~ ~~l.-~ lIei~t . Parking Requirements or Improvements 5/ 4 77 P f:? if 7. l.'''' Landscaping/Buffering 01 a.t~ 11-0 -iA..J ,uJuM /"h.i,u t-? A I/,U,.A-. Non-conforming Use or Change in se Other Zoning Changes Required 2iV DV? -1f'1 ~tNY' 1'V{ Size lIazardous Material Notes and Comments MIA) /05/ 7 '~1. . ( , ~ .f '<:9 ';' ~U~., NOTICE: The purpose of this conference shall be for staff and applicant to discuss overall commun ty goals, objectives, policies and codes as related to the proposed development and to discuss site plan review procedures. Opinions expressed at the pre-application conference are not binding for formal review purposes. Additional staff comments may be forthcoming based on actual plans submitted for review. S:\Planning\Planning\Pre-App Form pp 1-3\Pre-application Form p2.doc _ . * Must lACtlJe 'v\ 0 'lWV\ vc{ 0e'lt c~ fre -It-P pM <( e .f:-rt I ! PRE-APPLICATION MEETING SIGN IN SHEET PLEASE PRINT MEETING DATE: G -is r_ Db TIME: ATTENDING FOR APPLICANT: NOTICE: The purpose of this conference shall be for the staff and applicant to discuss overall community goals, objectives, policies and codes as related to the proposed development and to discuss site plan review procedures. Opinions expressed at the pre-application conference are not binding for formal review purposes. Additional staff comments may be forthcoming based on actual I bmi d ~ . plans su tte or reVIew. City of Boynton Beach Attending for Applicant Attendin2 Staff 1 : , l. " L _~ . \ 4#:1~(//1jj?err1_ i " U b ~ ER/c va 11/>1SC)y1 S:\Plannlng\Plannlng\Pre-App Form pp 1-3\Pre-appllcatlon Form p3.doc " IV 0 fL 1h . be/l1Jl/'2J:v," ~ cfr; '] , M 'fc/i{ t~ Time and Date of Meeting b//5/0(O /O~ ThOse.,~g~m~J _~kl PRE-APPLICATION CONTACT QUESTIONS Applicant's Name: U,{~ Phone: Ji,/ ~/ - /5g3 1. HAVE YOU SPOKEN TO ANY STAFF MEMBER ABOUT THE PROJECT? Yes No (IF YES, HA VB THOSE STAFF MEMBERS BEEN SCHEDULED FOR THE PRE- APPLICATION MEETING? 2. STAFF MEMBERS NAME: LOCATION OF Pj.~RTY (CROSS STREETS/INTERSECTIONS) ,_ f} .L2r. C2UiCp. ~'HfJ!":::~ >- 3. WHAT WOULD YOU LIKE TO DO? NEW PROJECT BUILDING EXPANSION OR MODIFICATION CHANGE IN PRIOR USE? IS THE STRUCTURE CURRENTLY VACANT? VARIANCE TYPE: POOL OR SCREEN ENCLOSURE COMMERCIAL PROPERTY? RESIDENTIAL PROPERTY? INDUSTRIAL PROPERTY? DO YOU KNOW THE ZONING CODE DESIGNATION? 4. TIME AND DATE PREFERRED 5. HOW MANY PEOPLE WILL BE AT THE PRE-APP MEETING? Note: Tell the person that someone from the Department will call them to confirm the meeting. .................................................................................. · Pre-application meetings should be scheduled for a minimum of one (1) hour time module, and should be scheduled no less than two (2) days prior to date/time of meeting. If urgency is sensed, discuss with Mike, · Meetin2s may be scheduled: Monday afternoons Tuesday all day Wednesday all day Thursday mornings Note: Mike is not available on Mondays between 11 :30 a,m. and 2:30 p.m S:\Planning\Planning\Pre-App Fonn pp 1-3\Pre-application Form p l.doc .-- . clJfP PROJECT NAME: North General Center of Medicine FILE LOCATION: West side of Federal Highway; South of the C-16 Canal PCN: 08-4345-22-08-000-0130 I FILE NO.: NWSP 07-001 II TYPE OF APPLICATION: I AGENTICONTACT PERSON: OWNER: Dr. Jean Renelien Roy Dunworth United Medical Enterprises, Inc. Dunworth Construction Inc. ADDRESS: 1550 N. Federal Highway, #16 ADDRESS: 625 SW Salerno Road Boynton Beach, FL 33435 Stuart, FL 34997 FAX: same as agent FAX: 772-463-2105 PHONE: same as agent - PHONE: 772-215-3438 E-Mail: Dunworthconstruction@yahoo.com SUBMITTAL 1 RESUBMITT AL 10/4/06 1 ST REVIEW COMMENTS DUE: 10/20/06 PUBLIC NOTICEI SIGNS 30 days 110 days 12/01/06 IPARC: TART MEETING: 11/7/06 LEGAL AD PLANNING & DEVELOPMENT BOARD MEETING: COMMUNITY REDEVELOPMENT 12/12/06 AGENCY BOARD CITY COMMISSION MEETING: 1/2/07 COMMENTS: y S-\Planning\SHARED\WP\PROJECTS\North General Center of Medicine\2006 PROJECT TRACKING INFO,doc