Loading...
DRAWINGSProposed Interior for: "Worldwide Superabrasives Ll C 2921 Commerce Park Dr. - Boynton Beach, Florida 33426 DRAWINGS CONTAINED HEREIN ARE COPYRIGHTED AND SHALL NOT BE TRANSCRIBED, COPIED, OR PARAPHRASED WITHOUT ARCHITECTS WRITTEN CONSENT. Gustavo.J. Carbonell, P,A, Z J MIA H CD �O "�'�N y M � ,c i M ���� 16 O _ , Z z IL 0 � a�NC k o 0. N m i v 0 ■ 0 0 a Gustavo J. Carbonell, P.A. Architecture and Planning 1457 NE 4th Avenue Fort Lauderdale Florida 33304 GUS CARBONELL, AIA gcarbonell o g jc.com www.guscarbonell.com T: 954.462.6565 F: 954.527.0857 SHEET INDEX NORTH p #3 f P"R ..�$ ���9'E 3 >�e r,;t� �k�v. 3,y sry E{ —1 EXISTING & DEMOLITION 1ST. FLOOR PLAN E -1 1ST. FLOOR POWER PLAN W D-2 EXISTING & DEMOLITION 2ND. FLOOR PLAN P-0 1ST. FLOOR PLUMBING PLAN A -1 NEW FIRST FLOOR PLAN E -1.1 1ST. FLOOR LIGHTING PLAN P -1 PLUMBING 1ST. FLOOR PARTIAL PLAN .. A -2 NEW SECOND FLOOR PLAN E -2 2ND. FLOOR POWER PLAN P -2 PLUMBING 1ST. FLOOR PARTIAL P E -3 ELECTRICAL PANELS LAN A -3 NEW REFLECTED CEILING PLAN P -2.1 PLUMBING 2ND. FLOOR PARTIAL PLAN A-4 SECTIONS E-4 ELECTRICAL RISER &SCHEDULES P -2.2 PLUMBING RISERS DIAGRAM P -3 WASTE PIPING & COMPRESSED AIR PLAN M -1 1ST. FLOOR CEILING PLAN HVAC P -3.1 WASTE PIPING & COMPRESSED AIR RISERS M -2 2ND. LEVEL CEILING PLAN HVAC P-4 PLUMBING NOTES, SCHEDULES & DETAILS M -3 NOTES, DETAILS & SCHEDULES HVAC FS -1 1 ST. FLOOR FIRE SPRINKLER PLAN FS -2 FIRE SPLINKLER NOTES & DETAILS ARCHITECT OWNER CONSULTING ENGINEERS '''lSTAVO J. CARBONELL, P.A. Architect and Planner CARLOS OCHOA CHRIS WINKEL Member American Institute of Architects Architectural Project Manager 1 1 4C 4//(eD) Phone: (954) 462 -6565 Ext. 15 President LEONARDO NAVEIRAS, INC. 1457 N.E. 4th AVE. Phone: (954) 462 -6565 Fax: (954) 527 -0857 Worldwide Superabrasives "CONSULTING ENGINEERS" Lauderdale, Florida, 33304 Fax: (954) 527 -0657 E -mail: cochoa�gjcarch.com E- Phone 954.828.9650 Leonardo Naveiras P.M. E -Mail: gcarbo"aN(�Wuarch.com CA# 25830 Julio C. Vidal P.E. PE# 52792 1918 Harrison St. # 207 Hollywood, FL 33020 Phone: 954 -270 -4822 Fax 954- 241 -6850 E -mail: hvedeo@aol.com n C I _ 01 V n ICJ Q[ b �_ 2010 cC ;icy SUiLDIN ;-D F W W Z H W O V GUST Q0 4J. CARSONELL NE »y YO g 39f> 1 � 0. R LORIE�{$ETION 4 NO. .00(0)7957 ISSUED FOR PERMIT DRAWN /CK'D: CFOS /GJC DATE ISSUED: 12.22.09 GJC PROJECT: 09.089 A=O ■ ■ J MIA H CD �O "�'�N y M � ,c i M ���� _ , z IL E � a�NC o 0. N m i ■ F W W Z H W O V GUST Q0 4J. CARSONELL NE »y YO g 39f> 1 � 0. R LORIE�{$ETION 4 NO. .00(0)7957 ISSUED FOR PERMIT DRAWN /CK'D: CFOS /GJC DATE ISSUED: 12.22.09 GJC PROJECT: 09.089 A=O EXIST. DOOR TO REMAIN 2 I I . I. I UP EXIST. DOOR TO REMAIN Z EXIST_ PARTITION TO BE REMOVED METAL HALIDE EXIST. DOOR TO REMAIN FROfi ERT LINE i I I II EXIST. DOOR — TO REMAIN EXIST. PARTITION TO BE REMOVE —� 1 Uf EXIST. DOOR 1 HR. F.R. TO REMAIN EX15T. _ PARTITION . F.R. TO REMAIN ----------------------------- - - - - -- 1 EXIST. I HR. F.R. STAIR ENCLOSURE � z_ I uI EXIST. STAIR TO REMAIN. EXIST. DOOR TO REMAIN. EXIST. PARTITION TO BE REMOVED EXIST_ DOOR TO REMOVED EXIST. PARTITION TO BE REMOVE EXIST. DOOR TO REMAIN. m EXIST. DRINKING � FOUNTAIN TO REMAIN � DOOR TO REW _ p =XIST BATH EXIST. A/G TO TO R MAIN REMAIN EXIST. PARTITION TO REMAIN. i EXIST. CMU ALL EXIST. FPARTITION EXIST. HI FLOW DRINKING TO REMAIN. TO REMAIN. FOUNTAIN I I EXIST. PARTITION 4 EXIST. PARTITION TO BE REMOVED z J I� EXIST_ W.G. TO BE o EXIST. 1 HRo w REMOVED 8 ADD x F.R. STAIR UP NEW SERVICE SINK a- X ENCLOSURE I F 0 -- NEW SERVICE SINKm' , w "16 ----------------------- - ,- g DOOR m ' - - - - -- ., - -- - - - - -- - - - -- \\ TO BE REMOVE : : Z =XIST. BATH � / TO iEMAIN r - _EXIST. BATH ad. TO REMAIN � REM N B EXIST. M IN TO .8 p a p � o o EzNTRA�IC II : -- - - - - -- a ------------------------ - - -- - -- - - - - --------------- p ------ - - - - ®- a - - -- -- - - -- - - - - - -- - - - - - -- - a------- - - - - -- ----- - - - - -- & - - - -- - -- - -- ---- - -p - -- a a p a °EXIST- WALK WAY ° 4 d° a a s G a p d a d 4 fi ROF'ERT'' LINE __ _____ O I4< ULTRA -- 4 A--- ______ -__ d HK FEETER 1 z p a ° a. SCALE I 40 RUSEL a ° 41 a 2 1 p ° SUMP PUMP UNDER SINK d a r - _EXIST. BATH ad. TO REMAIN � REM N B EXIST. M IN TO .8 p a p � o o EzNTRA�IC II : -- - - - - -- a ------------------------ - - -- - -- - - - - --------------- p ------ - - - - ®- a - - -- -- - - -- - - - - - -- - - - - - -- - a------- - - - - -- ----- - - - - -- & - - - -- - -- - -- ---- - -p - -- a a p a °EXIST- WALK WAY ° 4 d° a a s G a p d a d 4 fi ROF'ERT'' LINE 9 (,f� "U" ts D A U G3 s EXISTING & DEMOLITION FIRST FLOOR PLAN . NORTH 3 EQUIPMENT DATA o LE UJALL LEGE oos ° %'` ✓ ; EXISTING INTERIOR PARTITION TO BE REMOVED EXISTING INTERIOR PARTITION TO REMAIN NEW INTERIOR FULL HEIGHT PARTITION NEW INTERIOR lm' -m" HEIGHT PARTITION EXISTING FIRE RATED TENANT SEPARATION WALL - EXISTING 5/0" TYPE `X` DRYWALL EACH SIDE OF METAL STUDS UP TO ROOF DECK TO REMAIN. THROUGH PENETRATIONS SHALL MAINTAIN FIRE RATING OF SEPARATION WALL. UL U465 ONE HOUR FIRE RATED (VERIFY EXISTING). NOTE: SOME PORTIONS 2 HR. F.R. (NOT REQUIRED) EXISTING EXTERIOR MASONRY WALL. X1571N E) l / TENANT S FARATION LIJALLS 1. FIRE RATED WALLS SHALL BE MAINTAINED WITH PROTECTED OPENINGS AND SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING ABOVE DECORATIVE CEILING AND IN CONCEALED SPACES. SUGGESTED WORDING "FIRE AND SMOKE BARRIER PROTECT ALL OPENINGS" - THE ONLY REQUIRED FIRED RATED PARTITIONS ARE TO ENCLOSE STAIRS. 2. FIRE RATED WALLS SHALL BE MAINTAINED AT FIRE SEAL PROTECTION WHERE WALL MEETS CONCRETE ROOF DECK - FIRE RATING (VERIFY EXISTING) 12 1 WALL LEGEND I z 4 N— t � T H 10 11 20 27 2a 2e 47 Ulf','IEN7 E:�47,4 38 I4< ULTRA 4 10 3 HK FEETER 1 z H.K. SIEVE 1 SCALE I 40 RUSEL 1 I 41 SCALES 2 1 V14C. PUMP 1 SUMP PUMP UNDER SINK 1 MIXERS 2 HOT PLATES 2 -42 VIE3 RA60NIC I I EMERGENG'T' SLOWER 8 EYE WASH I z 23 REFIC- �EF�A70R I Z IL E Em Z � 2 I C� O N AM C 9 (,f� "U" ts D A U G3 s EXISTING & DEMOLITION FIRST FLOOR PLAN . NORTH 3 EQUIPMENT DATA o LE UJALL LEGE oos ° %'` ✓ ; EXISTING INTERIOR PARTITION TO BE REMOVED EXISTING INTERIOR PARTITION TO REMAIN NEW INTERIOR FULL HEIGHT PARTITION NEW INTERIOR lm' -m" HEIGHT PARTITION EXISTING FIRE RATED TENANT SEPARATION WALL - EXISTING 5/0" TYPE `X` DRYWALL EACH SIDE OF METAL STUDS UP TO ROOF DECK TO REMAIN. THROUGH PENETRATIONS SHALL MAINTAIN FIRE RATING OF SEPARATION WALL. UL U465 ONE HOUR FIRE RATED (VERIFY EXISTING). NOTE: SOME PORTIONS 2 HR. F.R. (NOT REQUIRED) EXISTING EXTERIOR MASONRY WALL. X1571N E) l / TENANT S FARATION LIJALLS 1. FIRE RATED WALLS SHALL BE MAINTAINED WITH PROTECTED OPENINGS AND SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING ABOVE DECORATIVE CEILING AND IN CONCEALED SPACES. SUGGESTED WORDING "FIRE AND SMOKE BARRIER PROTECT ALL OPENINGS" - THE ONLY REQUIRED FIRED RATED PARTITIONS ARE TO ENCLOSE STAIRS. 2. FIRE RATED WALLS SHALL BE MAINTAINED AT FIRE SEAL PROTECTION WHERE WALL MEETS CONCRETE ROOF DECK - FIRE RATING (VERIFY EXISTING) 12 1 WALL LEGEND I z 4 N— t � T H 10 11 20 27 2a 2e 47 Ulf','IEN7 E:�47,4 EG2LIPMENT DESCRIPTION QTY. CONICAL 10 RECTIFLERS T HEATERS 1 H.K. SIEVE 1 SCALE I 5AL,4NCE I V15R,4TOR I PACKER 1 EXHAUSTER 1 V14C. PUMP 1 SUMP PUMP UNDER SINK 1 MIXERS 2 HOT PLATES 2 N.K. SIEVE I SCALE I EMERGENG'T' SLOWER 8 EYE WASH I DRAWINGS CONTAINED HEREIN ARE COPYRIGHTED AND SHALL NOT BE TRANSCRIBED, COPIED, OR PARAPHRASED WITHOUT ARCHITECTS WRITTEN CONSENT. Gustavo.J. Carbonell, P,A. 13 MIXERS - 450VE TANKS 2 Z 0 O M p i� PUMPS N In 10 COMPRESOR (ON 1 I ,O 1 HEATER NNSIDE TANK #o) 2 3 i8 LEVEL SENSORS C Z IL E Em Z 2 0 IL O N AM C Im N t U 1 20 SULK i" f IXERS 3 V 21 SORTER 7-4 2 HA 22 PACKER TA5LE z O d Q ■ O 1 25 A.D.A. DRINKING FOUNTAINS 2 z 12 DEHJU 11)IFIEf;�- NO HEATING ELEI LENT 3 14 ll1ASTE TANKS 10 O U 31 SCALES 3 32 PRINTER 1 � p- 33 5TORAC3E RACKS 4 >r 34 FRI= TESTER = NO EXHAUST I 3� FURN,4CE 1 0 3o OVEN I DRAWINGS CONTAINED HEREIN ARE COPYRIGHTED AND SHALL NOT BE TRANSCRIBED, COPIED, OR PARAPHRASED WITHOUT ARCHITECTS WRITTEN CONSENT. Gustavo.J. Carbonell, P,A. Z 0 O M p ■' N L M ,O IL 06 3 O a C Z IL E Em Z 2 0 IL O N AM C Im N t 3 O ■ O D d F D a Gustavo J. Carbonell, P.A. Architecture and Planning 1457 NE 4th Avenue Fort Lauderdale Florida 33304 GUS CARBONELL, AIA gcarbonell ® gjc.com www.guscarbonell.com T: 954.462.6565 F: 954.527.0857 Z d Z O H J O W D GUST LL ', 0 CIL M � Ch FLORIDA FlEGISTRAT� NO. 0007957 ISSUED FOR PERMIT DRAWN /CK'D: CFOS /GJC DATE ISSUED: 12.22.09 GJC PROJECT: 09 -089 D=1 ■ ■ 0 H p ■' N L M ,O IL ■ 3 � a C Z IL E Em m 2 0 IL 4) N AM C Im N m 3 O ■ Z d Z O H J O W D GUST LL ', 0 CIL M � Ch FLORIDA FlEGISTRAT� NO. 0007957 ISSUED FOR PERMIT DRAWN /CK'D: CFOS /GJC DATE ISSUED: 12.22.09 GJC PROJECT: 09 -089 D=1 DRAWINGS CONTAINED HEREIN ARE COPYRIGHTED AND SHALL NOT BE TRANSCRIBED, COPIED, OR PARAPHRASED WITHOUT ARCHITECTS WRITTEN CONSENT. Gustavo.J. Carbonell, P,A. Z O 99 N6 O Z O k C D a Gustavo J. Carbonell, P.A. Architecture and Planning 1457 NE 4th Avenue Fort Lauderdale Florida 33304 GUS CARBONELL, AIA gcorbonell O g jc.com www.guscarbonell.com T: 954.462.6565 F: 954.527.0857 J J H O '' Z N 0 A 0. _��`` Z z CL E _ �a 2 0 m F- e muJ a O bow N 0 L m W 3 0 0 GUSTAI�WJ. C#4 AR CA t 1 E L .,. in e � C7 CJ I a d 14 FLOF� REG#STRAW& N &� 0007957 ISSUED FOR PERMIT DRAWN /CK'D: Ci /GJC DATE ISSUED: 12 .22.09 GJC PROJECT: 09089 Dm2 PAINTED 2" WIDE YELLOW STRIPES I" LETTERS ON WALL " MAINTAIN CLEAR AT ALL TIMES" s s 1 1:1 1 PROPERT'7' LINE PARKING AREA f TYPE OF CONSTRUCTION VP OCCUPANCY - B (BUSINESS) 4 F2 (LOW HAZARD OCCUPANCY) SPRINKLED No. OF EMPLOYEES = 10 PEOPLE TOTAL SU I L D INCA FOOTPRINT = 9,002 5.F. LEVEL OF ALTERATION = II NFPA 101 2006 - NFPA 1 2006 - FBC 2001 R "2 JJ,4 L L L o f E) EX15TINGs INTERIOR PARTITION TO BE REMOVED EXISTING INTERIOR PARTITION TO REMAIN NEW INTERIOR FULL HEIGHT PARTITION NEW INTERIOR lm' -m" HEIGHT PART 1 T I ON ' 7 EXISTING FIRE RATED TENANT SEPARATION WALL - EXISTING 5 /g" TYPE "X" DRYWALL EACH SIDE OF 3 -5/8" METAL STUDS UP TO ROOF DECK TO REMAIN. THROUGH PENETRATIONS SHALL MAINTAIN FIRE RATING OF SEPARATION WALL. UL U465 ONE HOUR FIRE RATED (VERIFY EXISTING). NOTE: SOME PORTIONS 2 HR. F.R. (NOT REQUIRED) EXISTING EXTERIOR MASONRY WALL. EXISTING DE�1151NC.:T / TENANT 5Ef=,4F,4T10N LUALLS I. FIRE RATED WALLS SHALL BE MAINTAINED WITH PROTECTED OPENINGS AND SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING ABOVE DECORATIVE CEILING AND IN CONCEALED SPACES. SUGGESTED WORDING "FIRE AND SMOKE BARRIER PROTECT ALL OPENINGS" - THE ONLY REQUIRED FIRED RATED PARTITIONS ARE TO ENCLOSE STAIRS. 2. FIRE RATED WALLS SHALL BE MAINTAINED AT FIRE SEAL PROTECTION WHERE WALL MEETS CONCRETE ROOF DECK - FIRE RATING (VERIFY EXISTING) 12 1 SCALE: LEGEND NEW FIRST FLOOR PLAN NORTH SCALE: 1/8" = 1'_0" o WINDOW SCHEDULE MARK O MARK SIZE TYPE ROUGH OPENING DIMENSION FRAME GLAZING EGRESS / SHUTTER PRODUCT PRODUCT ACCEPTANCE WIDTH HEIGHT MATERIAL FINISH 101 3' -0" x 6' -8" O Z 4 ESCAPE STEEL ACCEPTANCE REMARKS / QTY, I HR. F,R, W/ F,R, CLOSER W H (INCHES) (INCHES) MATERIAL FINISH GLASS FINISH STEEL STEEL E,S,P, PRIVACY Al 48" x 42" FIXED 103 ALUM ESP SAFETY CLEAR N ALUM. N/A PASSAGE 131 72" x 42" FIXED 104 ALUM ESP SAFETY CLEAR N ALUM. N/A PASSAGE DOUBLE ACTING W /VISION PANEL a 105 3 -0" x 6'-8' AUTO- SLIDING DR, 10 ALUM /SAFETY GLS ALUM. E,S,P, PASSAGE GENERAL MITES: 1, ALL WIND ❑WS UNLESS OTHERWISE NOTED SHALL BE ALUMINUM FIXED WIND ❑W, PRE - FINISHED (E,S,P.) WHITE, CLEAR. 2, GENERAL CONTRACTOR SHALL VERIFY AND CONFIRM WITH MANUFACTURER ALL ROUGH OPENINGS PRI ❑R TO START THE CONSTRUCTION. MAXIMUM 1/4" TOLERANCE BUCK TO WINDOW FRAMES. 3, ALL WINDOW HEADS AT 7' -0" A,F,F, DOOR SCHEDULE MARK O SIZE W H TYPE ROUGH OPENING DIMENSION MATERIAL FRAME HDWR, REMARK/ QTY, EGRESS / ESCAPE SHUTTER PRODUCT ACCEPTANCE WIDTH HEIGHT MATERIAL FINISH 101 3' -0" x 6' -8" SWING DR, Z 4 STEEL STEEL E.S.P. PASSAGE I HR. F,R, W/ F,R, CLOSER 102 4 -0" x 6' -8" SWING DR. SCALE STEEL STEEL E,S,P, PRIVACY NEW 3/4 HR, F,R, W /SELF CLOSER 103 4 -0" x 6' -8' SWING DR. ALUM /SAFETY GLS ALUM. E,S,P, PASSAGE DOUBLE ACTING W /VISION PANEL 104 (2)3' -0" x 6'-8" SWING DR. 1 Z ALUM /SAFETY GLS ALUM. E,S,P, PASSAGE DOUBLE ACTING W /VISION PANEL a 105 3 -0" x 6'-8' AUTO- SLIDING DR, 10 ALUM /SAFETY GLS ALUM. E,S,P, PASSAGE AUTO- SLIDING DR, W/ 3'X7' FIXED LT. 1 2 r 106 2 - 8" x 6' -8" SWING DR, 2T HOT SLATES WOOD WOOD PAINT PRIVACY EXISTING 2� SC,4LE 107 3 -0" x 6' -8' SWING DR. i' EFeENC" e, 40U R 4 E1'E UU451- 1 WOOD WOOD PAINT PRIVACY EXISTING / SELF CLOSER 1 1 - 4,50VE TANKS 2 108 3 -0" x 6' -8" SWING DR. ALUM /SAFETY GLS ALUM, E.S,R KEY LOCK EXISTING / STOREFRONT z 109 3 -0" x 6' -8" SWING DR, �` 1� STEEL STEEL E,S,R KEY LOCK EXISTING / REAR 17 110 12 -0" x 12' -0" OVERHEAD STEEL STEEL E,S,P, KEY LOCK EXISTING / REAR 111 3 -0" x 6' -8" SWING DR, WOOD WOOD PAINT PRIVACY EXISTING 20 E3 ULK M!XERS 3 112 (2)3 -0' x 6' -8" SWING DR, 2 z STEEL STEEL E.S,P KEY LOCK EXISTING 3/4 HR, F.R. Q 113 3 -0" x 6' -8" SWING DR, STEEL STEEL E. S. R STAIRS EXISTING I HR, F,R, W /SELF CLOSER 25 114 (2)3 -0' x 6' -8" SWING DR, WOOD WOOD PAINT PRIVACY EXISTING 11A 3 UJASTE T4NKS 115 4 -0" x 6' -8" SWING DR, STEEL STEEL E,S,P PRIVACY NEW 3/4 HR. F,R, W /SELF CLOSER 31 SCALES GENERAL NOTES: 1. ALL DOORS UNLESS OTHERWISE NOTED SHALL BE SWING DR. AS SELECTED BY OWNER, WITH CLEAR GLASS. 2, GENERAL CONTRACTOR SHALL VERIFY AND CONFIRM WITH MANUFACTURER ALL ROUGH OPENINGS PRI ❑R TO COMMENCEMENT OF THE CONSTRUCTI ❑N. MAXIMUM 1/4" TOLERANCE BUCK TO DOOR FRAMES, 3, ALL DOOR HARDWARE TO BELIEVER TYPE, FINISH TO BE SELECTED BY OWNER TYPICAL, 4. GENERAL CONTRACTOR TO COORDINATE DOOR HEIGHT WITH AVAILABLE HEAD ROOM. PRIOR TO INSTALATI ❑N, OCCUPANCY AREAS FIRST FLOOR OFFICE 602 SF SECOND FLOOR OFFICE 1,423 S.F. TOTAL OFFICE 2,025 S.F, GROUND FLOOR INDUSTRIAL 8,400 SF MEZZANINE INDUSTRIAL 643 S,F, TOTAL INDUSTRIAL 9,043 S.F, TOTAL OFFICE % 18,30% TOTAL INDUSTRIAL % 81.70% OFFICE % 1ST, FLOOR 602 S.F, 6.68% BUILDING FOOTPRINT 9,002 S.F. 100,007 APPLICABLE CODES FLORIDA BUILDING CODE 2007 FLORIDA FIRE PROTECTION 2007 OCCUPANT LOAD 1ST. FLOOR OCCUPANT = 70 2ND, FLOOR OCCUPANT = 14 TOTAL BUILDING OCCUPANT = 84 o IO ! NT L�`oT4 Z R ". OUI�MNT D�CRii�T ON OTC O CONICAL 0 RECTFL RS HEATERS T Z 4 H.K. e1FVE 1 W SCALE O Z O � V f ORATOR 1 Z �� 1 a EXHAUSTER 1 10 VAC. ='U1 1 1' SUI�� PUMA UNDER SINK 1 2 r 1° 2 2T HOT SLATES 2 2 H.K. S I E VE I 2� SC,4LE 1 47 i' EFeENC" e, 40U R 4 E1'E UU451- 1 z 1 1 - 4,50VE TANKS 2 W n z D �` 1� PU1°1�S (ON' IEZZANINEi 17 HE41­ER ! N51DE TANK 1 *o) 2 0 LEVEL SENSORS �C 20 E3 ULK M!XERS 3 2 SORTER TAFLE 2 z 22 PACK =R TAE3LE I - z Q 25 A.D.A. DR1NK!N HOL4N T AINS 2 z U 12 NO HEATING; L ❑1°'_NT 3 11A 3 UJASTE T4NKS 10 U U 31 SCALES 4 32 RRINTER STORA RA CKe 4 �U 34 PRI- TESTER NO FXHAUST 1 a5 FUIRN4CL 1 O 3� OVEN 1 HK ULTRA 3� HK FEET R } 40 RUSEL 41 SCALES 2 chi 42 VI5RA SON fC 1 u� z 23 R =I iz 4T0 R 1 C� q, WINDOW & DOOR SCHEDULE 3 EQUIPMENT DATA SCALE: N.T.S. SCALE: N.T.S. DRAWINGS CONTAINED HEREIN ARE COPYRIGHTED AND SHALL NOT BE TRANSCRIBED, COPIED, OR PARAPHRASED WITHOUT ARCHITECTS WRITTEN CONSENT. Gustavo.J. Carbonell, P,A. Z O W O Z O a D Q W Q D • /r Gustavo J. Carbonell, P.A. Architecture and Planning 1457 NE 4th Avenue Fort Lauderdale Florida 33304 GUS CARBONELL, AIA gcarbonell ® g jc.com www.guscarbonell.com T: 954.462.6565 F: 954.527.0857 ■ ■ J H > Z p , t0 ■� i N Q J 0 �M J IM6 CZ 0 ZIL E� E w U) U c IU. a. 4) N C F■ i 04 O y L ■� N m U 0 ■ GU,AjiTE CAR�ONELL q ua CT . "A. i, a FLORID# REG1VI`�ATION N0. ,0007957 ISSUED FOR PERMIT DRAWN /CK'D: CFOS /GJC DATE ISSUED: 12.22.09 GJC PROJECT: 09 -0$9 Aml NOTE. ALL LIQUIDS STORED UJITHIN A PERMANENTLY MOUNTED SIGN WITH I" BOLD TYPE LETTERS ON A CONTRASTINCz TYP. 3' -0" X &' -8" 5AC<GROUND WILL BE MOUNTED ADJACENT TO EACH STAIR WITH THE FOLLOWING WORDING' - ORIGINAL CONTAINERS ON SKID5 EXISTING STEEL DOORS PARKING (,�E � 'NO MORE M Y HALL RE THAN 5 EP=LOEES S _ !^ OC�_ Y CUP THE SECOND FLOOR ROOMS AND THERE _