Loading...
DRAWINGSREVISIONS I BY 1 A BLDG. DEPT. COMMENTS �P �P 8 -14- 2014 1 • 1 33X38 3IX38 00 i Mw II II rI I KITCHEN UTILITY CLG. COOKTOP/ NEW CONE). UNIT OPEN RELOCATE A.H.U. OO Qo A/C G.C. TO COORD. OO OO coND. W� IN FIELD ISLAND f A.H.U. CLOSET I FLUSH DINING AREA N N INFILL EXIST. OPNG. - 61 SEE DETAIL THIS SHEET X i m i REPLACE EXISTING T=RENCH DOORS W/NEW IMPACT PCsT NOA "12- 051(o.02 L 8' -0" CLG. EXISTING TO REMAIN U.O.N. LIVING FOYER NEW INTERIOR SPACE 8' -4" CLG. REMOVE EXISTING N DOORS PORCH N INSTALL NEW S.H. WINDOW (IMPACT) INFILL EXIST. OPNG. - (G.C. TO PROVIDE PRODUCT APPROVALS) SEE DETAIL THIS SHEET 2x8 P.T. W/ 1/4"x3 1/2" TAPCONS 016 O.C. STAGGERED (4" MIN. FROM ENDS" g , WALL LEGEND FLOOR PLAN EXIST. TO REMAIN Scale: 1/4 " =1' -0" - RRR9� INFILL EXTERIOR WALL WOOD TRUSSSES DOUBLE TOP PLATES EXIST. CONC. BEAM WOOD HEADEF (2)2x6 MIN. SIMPSON SP -8 WRAPPED OVER SILL PLATES LINE OF FLOC 3MPSON SP -8 9 EACH JACK STUD DOUBLE JACK STUDS NOTE: TYPICAL WOOD SILL TO BE (3) 2" X SPF #2 STUDS W/1/2" CDX PLYWOOD INBETWEEN EACH 4PPLICATION (3 1/2" THICK SILL) TYPICAL AT ALL WINDOWS NON- BEARING WALL STUDS (SEE SECTIONS) (2) SIMPSON SP -8 WRAPPED AROUND JACK AND WALL STUDS (TYPICAL EACH SIDE) SIMPSON SP -8 WINDOW OPENING IN CMU WALL DETAIL N.T.S. VICI N.T.S. • W LCJ I S EXIST. ROOF TO REMAIN . �CO EACH STUD �o co 1 � EXIST. CONC. T.B. TO REMAIN Lo LO C) (2)2x8 PLATE W/ 1/4"x5" TAPCONS @ 12" O.C., 4' FROM ENDS. w E-+ WIRE LATH & 30# FELT (PROVIDE DBL. LAYER OF I () LAYERS OF 300 UNDERLAYM APPROVED MOISTURE BARRIER) C9 WI LL BE INSTAI LED IN T MINIMUM OF 19" OR 2x6 @16" O.C. LO 1 /2 "EXT. GD. PLYWOOD WITH 8D RING SHANK NAILS O W R -19 INSUL. 4" O.C. @ EDGES AND 6" O.C. co H 1 ® CO U a w SP6 OR SP8 EA. STUD w 1/2 POWER WEDGE BOLTS @24" O.C. EMBED. INTO EXIST. FTG. � x � (9" LONG MIN.) 1 - #5 @ PERIMETER SEE PLAN FOR CONC. SLAB W � T.O.C. cD 0 ° � a MATCH EXIST. F.F. GRADE NNEW W MAIN HOUSE � [ EXIST. CONNC. SLAB co TO REM I -- I I / / EXIST. FTG. TO REMAIN L-- - - - --� WALL SECTION N.T,S. 4 3iX50 A 7 EIAL VIE EXIST. CONC. FTG. \ -- 2x8@16" O.C. MAX. N.T.S. TO REMAIN - V.I.F. FASTEN PT END STUD TO CMU W/ 1/4"x3 1/2" TAPCONS @ 12" O.C. 4' FROM TOP & BOTTOM (TYP.) PARTIAL FOUNDATION PLAN Scale: 1/4"=l'-O" R -30 INSUL. 0 INE10011 Q0 C Permit No. l REVIEWED BY DA F CYD CYD Szr uctur l P ®7® E ectrlcai �' � � 8• s s_ Plumblg C-) E fAechanical Pets 9 /7' .l R� Forester o E-4 o Fire J, F Police I Other ProcesseJ� t`iii ,40Yk I iVoECd on Ci ty e° Bo yn'tan 9 R a Cnees / ExP�tD 3-lU� 1*A�c1f-�F_ NO W O 0 'fir +✓' o w E� B UILD­' I G Y ESI ENTIAL USAGE ® .C. 2010 ASCE -7 -10 EXP. 'C' 170 H (U LT.) S CATEGORY 11 � u� ,v! 3000 PSI CONIC i,iue } 5 `° 4 7 2014 AC C 3r , FILE ���' IIItis TT SCHEFLLER TOBIN Wuuu TO BE SYP #2 DRAWN SCS DESIGN WIND PRESSURES: SCALE: AS NOTED WINDOWS (WORST CASE) ALL OPENINGS POS. +41.1 PSF NEG. -50.7 PSF SHEET # Iil S EXIST. ROOF TO REMAIN SIMPSON SP6 OR SP8 EACH STUD EXIST. CONC. T.B. TO REMAIN (2)2x8 PLATE W/ 1/4"x5" TAPCONS @ 12" O.C., 4' FROM ENDS. STUCCO OVER P.B. WIRE LATH & 30# FELT (PROVIDE DBL. LAYER OF I () LAYERS OF 300 UNDERLAYM APPROVED MOISTURE BARRIER) 2x8 @16" O.C. WI LL BE INSTAI LED IN T MINIMUM OF 19" OR 2x6 @16" O.C. OVERLAP PRIMES LESS THAN 4512 1 /2 "EXT. GD. PLYWOOD WITH 8D RING SHANK NAILS R -19 INSUL. 4" O.C. @ EDGES AND 6" O.C. 1 IN FIELD 2x8 P.T. BOTTOM PLATE SP6 OR SP8 EA. STUD 1/2 POWER WEDGE BOLTS @24" O.C. EMBED. INTO EXIST. FTG. (9" LONG MIN.) 1 - #5 @ PERIMETER SEE PLAN FOR CONC. SLAB T.O.C. cD ° ° X. X X— MATCH EXIST. F.F. GRADE MAIN HOUSE EXIST. CONNC. SLAB TO REM I -- I I / / EXIST. FTG. TO REMAIN L-- - - - --� WALL SECTION N.T,S. INE10011 Q0 C Permit No. l REVIEWED BY DA F CYD CYD Szr uctur l P ®7® E ectrlcai �' � � 8• s s_ Plumblg C-) E fAechanical Pets 9 /7' .l R� Forester o E-4 o Fire J, F Police I Other ProcesseJ� t`iii ,40Yk I iVoECd on Ci ty e° Bo yn'tan 9 R a Cnees / ExP�tD 3-lU� 1*A�c1f-�F_ NO W O 0 'fir +✓' o w E� B UILD­' I G Y ESI ENTIAL USAGE ® .C. 2010 ASCE -7 -10 EXP. 'C' 170 H (U LT.) S CATEGORY 11 � u� ,v! 3000 PSI CONIC i,iue } 5 `° 4 7 2014 AC C 3r , FILE ���' IIItis TT SCHEFLLER TOBIN Wuuu TO BE SYP #2 DRAWN SCS DESIGN WIND PRESSURES: SCALE: AS NOTED WINDOWS (WORST CASE) ALL OPENINGS POS. +41.1 PSF NEG. -50.7 PSF SHEET # Iil NEW C SCOPE OF HVAC' WORK: ALL HVAC IS EXISTING TO REMAIN U.O.N. INSTALL NEW COND. UNIT © EXISTING LOCATION. MECHANICAL PLAN Scale: 1/4"=V-0" ' -0" AIR CONDITIONING EQUIPMENT SCHEDULE MARK ARI BTUH T/S EER /SEER MANUFACTURER COND. UNIT MODEL# VOLT /4 MCOP AHU # CFM SUPPLY KW HEAT VOLT /4 MCOP OA NOTES AC -1 35000/28350 13.2/16 LENNOX 14ACX- 036- 230 -14 230/14 30/2 EXIST. TO REMAIN 1167 10 KW 230/14 30/2 — 1 2/40 1/2 1/2 SWITCHED OUTLET STOVE 3 WALL SCONCE Leo 4 21 1/2" 10 WATER HEATER 5 O GARAGE DOOR GFI 6 h E w -i H 1/20 1/2" 12 1. HEAT / COOL THERMOSTAT 1. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2010 FLORIDA BUILDING CODE, THE NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES. 2. THE ELECTRICAL SUBCONTRACTOR SHALL BE RESPONSIBLE FOR FULL COORDINATION OF THIS WORK WITH THAT OF THE GENERAL CONTRACTOR AND THE OTHER SUB — CONTRACTORS. 3. PROVIDE A GUARANTEE AGAINST DEFECTIVE WORKMANSHIP, MATERIALS AND EQUIPMENT FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE BY OWNER. 4. ALL POWER AND CONTROL WIRING SHALL BE BY THE ELECTRICAL SUB — CONTRACTOR. 5. ELECTRICAL SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ALL APPLICABLE FEES TAXES AND PERMITS. 6. WIRING DEVICES SHALL BE U.L. LISTED COMMERCIAL GRADE. 7. ALL CONDUIT SHALL BE RIGID GALVANIZED EXCEPT AS FOLLOWS: A: EMT MAY BE USED INDOORS, WHERE NOT SUBJECT TO ABUSE. B: PVC MAY BE USED UNDERGROUND WHERE ALLOWED BY CODE. 8. ALL WIRE SHALL BE COPPER. #10 AND SMALLER SHALL BE SOLID THHN. #8 AND LARGER SHALL BE STRANDED THHN. CONTROL WIRING SHALL BE # 14 THHN. 9. THESE PLANS ARE BASED ON AVAILABLE INFORMATION. NOTIFY ARCHITECT/ OWNER OF ANY CONDITIONS WHICH AFFECT PROGRESS OF CONSTRUCTION. 10. VERIFY ELECTRICAL REQUIREMENTS OF EACH PIECE OF EQUIPMENT PRIOR TO ACTUAL CONNECTION THERE —TO. 11. ESTABLISH FIELD LIAISON WITH PROJECT MANAGER PRIOR TO STARTING WORK. VERIFY ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT / OWNER OF ANY DISCREPANCIES. 12. ELECTRICAL SUBCONTRACTOR SHALL VERIFY LOCATIONS AND CONNECTIONS TO ALL ELECTRICAL EQUIPMENT FURNISHED BY OTHERS, PRIOR TO INSTALLING OUTLETS, CONDUIT STUBS DROPS ETC. VERIFY LOCATIONS OF ALL CONTROLS FURNISHED BY OTHERS. INSTALL CONTROLS AND MAKE CONNECTIONS THERETO. 13. PROVIDE AFCI PER NEC 210.12B FOR ALL REQUIRED RECEPTACLES. 14. PROVIDE TAMPER RESISTANT PER NEC 408.11 AND 210.52 FOR ALL REQUIRED RECEPTACLES. 15. ALL BATH OUTLETS TO BE GFI. 16. ALL PHONE / INTERNET LOCATIONS TO HAVE (2)CAT6 CABLES. 17. ALL T.V. LOCATIONS TO HAVE (2) CAT6 AND (2)RG6 COAXIAL CABLES. ELECTRICAL CALCS. GENERAL LIGHTING (2,036 SF x 3 VA) = 6108 VA WASHER = 1500 VA DRYER = 5000 VA WATER HEATER = 4500 VA RANGE = 8000 VA DISHWASHER / DISPOSAL = 2000 VA SMALL APPLIANCES = 3000 VA REFRIGERATOR = 1500 VA MICROWAVE = 1000 VA TOTAL LOAD = 32608 VA 1ST 1OKW © 100% A/C HEAT = 10000 VA REMAINDER @ 40% = 9044 VA HVA S = 10000 VA TOTAL DEMAND = 28826 VA _ 240V 121 A EXIST. 125 AMP SERVICE TO BE ADEQUATE (G.C. TO VERIFY IN FIELD) UTILITY 8' -0" CLG. D EXIST. 125A PANEL TO REMAIN NEW COND. UNIT A/C I�1 COND. A.H.U. OO OO OO � j ISLAND U CLOSET 11 N N J DINING AREA N N N LIVING J N I NEW INTERIOR SPACE 8'-4" CLG. KITCHEN N 0 N PORCH C ON SD N SD N N BEDROOM #2 -0' CLG. J N BEDROO #1 X " N )E SMOKE ALARMS (HARD WIRED) PER FBC 2010 R314.3.1 SHALL COMPLY WITH R314.4 (ARC FAULT PER 10.1213) (CARBON MONOXIDE FBC R- 315,FS 553) Smoke Alarms: 2010 FBC Residential R314.3.1 SCOPE OF ELEC. WORK: ALL ELEC. IS EXISTING TO REMAIN U.O.N. ADD LIGHTING POLES 32 AND OUTLETS PER PLANS. TYP EXISTING EXIST PANEL A.I.C. = 10,000 MAIN BUS 200A SERVICE 14/3W NEUTRAL FULL VOLTAGE 120/240 MAINS M.L.O. MOUNTING SURFACE LOCATION POLES 32 SEE PLAN NO. V A POLE TRIP COND WIRE DESCRIPTION C T 0 2/60 1/2" DUPLEX OUTLET A/C HANDLER 1 CO RECESSED FIXTURE SINGLE OUTLET 20 AMP w 2 2/40 1/2 1/2 SWITCHED OUTLET STOVE 3 WALL SCONCE Leo 4 21 1/2" 10 WATER HEATER 5 O GARAGE DOOR GFI 6 h E w -i H 1/20 1/2" 12 WASHER 7 1/20 1/2" 12 KITCHEN RECPT. 8 WATERPROOFED WP/GFI 1/20 1/2 12 FURNACE 9 GFI OUTLET 1/15 1/2" 12 A/C 10 240V SPECIAL 1/15 1/2" 12 MASTER BATH 11 PURPOSE OUTLET 1/15 1/2 12 BEDROOM HI HAT 12 W 1/15 1/2" 12 MASTER BED RECPT. 13 1/15 1/2" 12 GUEST BATH 14 1/15 1/2" 12 HALL / 2 BED RM. 15 1/15 1/2 12 KITCHEN / LIVING RM. 16 1/20 1/2" 12 FAN 17 1/20 1/2" 12 LAUNDRY RECPT. 18 2/30 3/4" 10 DRYER 19 W 20 1/20 1/2" 12 MIRROR WALL / HI HAT / FAN 21 1/20 1/2" 12 FRONT DOOR HI HATS 22 2/30 3/4" 10 A/C COMPRESSOR 23 24 1/20 1/2" 12 DINING ROOM LTG. / RECPT. 25 W SPARE 26 SPARE 27 SPARE 28 C; SPARE 29 SPARE 30 SPARE 31 SPARE 32 NEW CKTS. SHOWN BOLD N POWER / LIGHTING rr"LAN w .- All Electrical work shal comply with the 2008 NEC All branch circuit conductors, loads and circuit breakers, shall be sized according to the National Electrical Code and be verified in the field. To be verified in the field FC,- IR1:,.' 1_G0,,M1P . THr2008NKIIONALPwlEC) IC LCODE I. CLOSET M BEDROOM CLOSET SD 8'­ CLG. N '` 8' -0" CLG. EXIST. POWER / LIGHTING TO REMAIN U.O.N N SD N N When additions, alterations or repairs requiring a permit occur, or when one or more sleeping rooms are added or created in existing dwellings , the individual dwelling unit shall be equipped with smoke alarms located as required for new dwellings. See exceptions 1 and 2. The 120 volt power source shall comply with R314.4 The smoke alarms shall be interconnected and hard wired. The circuit shall be arc fault protected per NEC 210.12B. Smoke alarms are required inside each bedroom and immediately outside the bedroom doors. The smoke alarms shall be inspected. BATH L90 U REVISIONS I BY 8 -14 -14 NEW SHEET PER T. T. RI nr-, r1FPT (Y1hAhAFMTC SURFACE MOUNT FIXTURE ® ELECTRIC PANEL $ WALL SWITCH WALL MOUNT FIXTURE ro ELECTRIC METER co 3 3 -WAY SWITCH 0 HANGING FIXTURE DUPLEX OUTLET $4 I co CO CO RECESSED FIXTURE SINGLE OUTLET 20 AMP w 4 -WAY SWITCH 1/2 SWITCHED OUTLET WALL SCONCE Leo m W 0 J CEILING PADDLE O GARAGE DOOR GFI GROUND FAULT h E w -i H FAN (OPTIONAL) OPENER INTERRUPTER OUTLET i JUNCTION BOX WATERPROOFED WP/GFI GFI OUTLET TELEPHONE JACK SD SMOKE DETECTOR W/ 240V SPECIAL C CARBON MONOXIDE DETECTION E PURPOSE OUTLET W TELEPHONE JACK SD SMOKE DETECTOR W/ W CABLE T.V. OUTLET 18" A.F.F. O THERMOSTAT N INDICATES NEW POWER U 4 W REVISIONS I BY 8 -14 -14 NEW SHEET PER T. T. RI nr-, r1FPT (Y1hAhAFMTC ���1 R l� AUG DATE 7.7.2014 FILE TT SCHEFLLER TOBIN DRAWN SCS SCALE: AS NOTED SHEET -# FOYER N Y V' O V' co s C\? W Q � � I co CO CO W E ..1 w Leo m W 0 O 0 N h E w -i H I� c\2 E a' W *I - �, W O CO � U 4 W w W H U � a c W C; b f � ���1 R l� AUG DATE 7.7.2014 FILE TT SCHEFLLER TOBIN DRAWN SCS SCALE: AS NOTED SHEET -# FOYER N Y O di C''J co � W Q � � W E ..1 w m W O 0 N h E w -i H I� ���1 R l� AUG DATE 7.7.2014 FILE TT SCHEFLLER TOBIN DRAWN SCS SCALE: AS NOTED SHEET -# FOYER N Y