DRAWINGREVISIONS i ment comments revision MECHANICAL NOTES 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY, FOR THE INSTALLATION OF A COMPLETE SYSTEM IN ACCORDANCE WITH THESE DRAWINGS, THE APPLICABLE BUILDING CODE AND ALL OTHER APPLICABLE STATE, COUNTY AND LOCAL ORDINANCES AND THE LATEST ADDITION OF THE FOLLOWING PUBLICATIONS; SMACNA, ASHRAE, NFPA 90A, 90B, 91 & ANSI B -9.1 MECHANICAL REFRIGERATION. 2. THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK. DESIGN REQUIREMENTS REQUIRED DUCT SMOKE DETECTOR NO FIRE DAMPER(S) NO SMOKE DETECTOR NO FIRE RATED ENCLOSURE NO FIRE RATED ROOF/FLOOR NO FIRE ST ❑PING NO SMOKE CONTROL NO 1. NO FIRE WALLS IN DUCT PATH AND NO FIRE DAMPERS REQUIRED EXCEPT WHERE OTHERWISE SHOWN ON THE PLAN 50 2• DUCT LAYOUT TO REMAIN AS IS, CEILING DIFFUSERS TO 1 x 2 REMAIN, CONTRACTOR TO ADJUST FLEX DUCT IF NEEDED. 3. ALL ROOF PENETRATIONS MUST BE PERFORMED BY LANDLORD APPROVED ROOF CONTRACTOR €EF- 5 0 EF -2 HUNG FROM 2"X2" ANGLE IRON SUPPORTS WITH I 4. INTERLOCK EF -2 WITH RTU -1 # x 4 SPRING TYPE VIBRATION HANGERS 3. THE CONTRACTOR SHALL VISIT THE SITE AND COORDINATE WORK WITH OTHER TRADES. WITH AN OVERRIDING SWITCH M 5. RTU -1 EXISTING TO REMAIN BARD P1130A2 4. THE CONTRACTOR SHALL SUPPLY THE ARCHITECT WITH "AS- BUILT" DRAWINGS. SO THAT EF -2 WILL TURN ON 6. CONTRACTOR TO MAINTAIN EXISTING UNIT AND ENSURE 5. CONTRACTOR SHALL SUBMIT, FOR APPROVAL FIVE [5] COPIES OF MANUFACTURER'S HVAC DESIGN REQUIREMENTS WHEN ' M2 RTU - IS ON. PROVIDE PROPER OPERATION TO SATISFY THIS PLAN AND CONSULT DRAWINGS FOR EACH PIECE OF EQUIPMENT AND CONTROLS INCLUDED IN CONTRACT. AND OVERRIDING SWITCH TO s _ WITH ENGINEER IN CASE OF DISCREPANCY 6. ALL MATERIAL SHALL BE NEW OF U.S. MANUFACTURER OF GOOD QUALITY. ALL WORK ALLOW TURNING EF -2 ALONE. _ 5 7. NEW EXHAUST FAN AND EXHAUST DUCT AS PER THIS PLAN. N E12 SHALL BE PERFORMED IN A WORKMANLIKE MANNER BY SKILLED WORKMAN. 1 x 2 7. ALL AIR CONDITIONING DUCT WORK SHALL BE OF 1-1/2" (R -6) STANDARD DUTY FOIL LEGEND WA N I REINF FIBERGLASS WITH MANUFACTURERS LOGO PRINTED ON VAPOR BARRIER E 50 r ALL FLEX TO BE R- 6 . ® NEW SUPPLY AIR CEILING DIFFUSER x 2 8. ALL EXHAUST DUCTS AND OUTSIDE AIR DUCTS SHALL BE GALVANIZED SHEET METAL EXISTING WITH SEALED SEAMS AND JOINTS. NEW RETURN AIR CEILING GRILLE " "'Y': `- x 4 � �; � -�i ; :� RTU -1 9. DUCT SIZES SHOWN ARE INSIDE DIMENSIONS. t� WALL LOUVER / WALL DIFFUSER. -_ _ (BARD P1130A2. 3 TONS) _ .r...7 10. ALL AIR DEVICES (DIFFUSERS, REGISTERS AND GRILLES) SHALL BE ALL ALUMINUM A.LD. FIRE DAMPER, ALL FIRE DAMPERS I SHALL BE FIRE SMOKE DAMPERS CONSTRUCTION WITH EXPOSED SURFACE OFF WHITE BAKED ENAMEL FINISH TO MATCH EXISTING OR AS SPECIFIED BY ARCHITECT. DEVICES SHALL BE TITUS, METALAIRE, AIRGUIDE. A.= FIRE SMOKE DAMPER I PROVIDE OPPOSED BLADE DAMPERS AT ALL DIFFUSERS AND REGISTERS. ` VOLUME CONTROL DAMPER 1 . RUN DUCT BETWEEN CHAIRS TO WALL 11. THERMOSTAT SHALL BE COMBINATION COOLING /HEATING, WITH SYSTEM "COOL -AUTO- p THERMOSTAT AND THEN TO ABOVE CEILING IN HEAT - OFF" AND FAN "ON - AUTO" SELECTOR SWITCHES. PROVIDE PROGRAMMABLE TYPE, p HUMIDISTAT THREE LOCATIONS AS SHOWN, AND �IRtj I E�EVP�ILE� •FbROXLQEATP�NtF KJGCPtiPK TENT BEFORE STARTING �� NEW FLEX DUCT CONNECT TO EF -2 1 "" 12. AL ACCEPT 2. FROM EF -2 TO WALL CAP ' -- THEM. REPLACE THEM PRIOR TO FIN ACCEPTANCE BY OWNER. 1 NEW DUCTWORK 3. INSURE 1 MINIMUM OF 10' FROM ANY 33- SUPPLY TOP REGISTER (WALL TYPE) OUTSIDE AIR SUPPLY. 13. PROVIDE SMOKE DETECTORS WITH ACCESS DOORS IN ALL SUPPLY AIR DUCTS FOR 4. PROVIDE 6 (6 "X4 ") GRILLES ONE ON I �� RETURN OR EXHAUST TOP REGISTER A COMMON PLENUM OF 2000 CFM OR ABOVE. ALL SMOKE FANS AND AHU'S SERVING '� OR GRILLE WALL TYPE (AIR INTO EACH SIDE OF THE THREE DUCTS � DETECTORS SHALL BE BY ONE MANUFACTURER, COORDINATE VOLTAGE ETC. WITH DEVICES) BETWEEN CHAIRS. ELECTRICAL CONTRACTOR AND FIRE ALARM SYSTEM BEFORE ORDERING. UPON INCLINED RISE IN DIRECTION 5. COORDINATE GRILLES LEVEL AND = A E OF AIR FL OW, FLAT BorroM W ;{ 250 DETECTION SMOKE DETECTORS SH UT DOWN ASSOCIATED AIR MOVING AND EQUIPMENT LOCATION WITH THE CHAIR LEVEL y ALL AIR MOVING EQUIPMENT SERVING THAT COMMON PLENUM. INCLINED DROP IN DIRECTION :` OF AIR FLOW, FLAT BOTTOM 4 _ 14. PROVIDE TYPE "B DAMPERS IN ALL DUCTS OR OPENINGS PENETRATING FIRE DIFFUSER OR GRILLE DESIGNATION RATED WALLS, MECHANICAL AND ELECTRICAL EQUIPMENT ROOMS, TENANT SEPARATION, ROOF EXHAUST FAN E x PARTITIONS, FLOOR OR ROOF SLABS AND AT Q/A INTAKES. PROVIDE RADIATION I RADIATION DAMPERS IN RATED CEILINGS FOR ALL CEILING OPENINGS, CEILING FANS, ORE) EXHAUST FAN DIFFUSERS OR GRILLES RATED FOR USE IN THE CEILING ASSEMBLY. I gRo FLEXIBLE CONNECTION € E 15. THERMOSTAT LOCATION SHALL BE APPROVED BY OWNER AND ENGINEERS BEFORE AFC DUCT TURN WITH TURNING VANES (T.V.) - PROVIDE ALL SQUARE OR _ A INSTALLATION � RECTANGULAR. ELBOWS WITH VANES € 250 EVEN IF SYMBOL IS MISSING 16. PROVIDE A MIN. OF 3 CLEARANCE IN FRONT OF ALL 120 -240 VOLT PANELS AND 4 ' 2 x 4 CLEARANCE IN FRONT OF ANY 480 VOLT PANEL. PROVIDE ADEQUATE SIDE STANDARD RADIUS ELBOW, ROUND CLEARANCE PER NEC DUCT ALL SQUARE OR RECTANGULAR ELBOWS WITH VANES EVEN IF SYMBOL IS MISSING. 17• MECHANICAL PLANS IN GENERAL, ARE DIAGRAMMATIC IN NATURE, AND ARE TO BE READ CONJUNCTION WITH ARCH. PLUMBING, ELECTRICAL AND STRUCTURAL PLANS AND uP SUPPLY & OUTSIDE AIR SECTION (UP) I IN C SHALL BE CONSIDERED AS ONE SET OF DOCUMENTS. DUCT AND PIPING OFFSETS, BENDS QON SUPPLY & OUTSIDE AIR SECTION (DOWN) AND TRANSITIONS WILL BE REQUIRED TO PROVIDE AND INSTALL A COMPLETE FUNCTIONAL SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO UP RETURN &EXHAUST DUCT SEC (UP) I € ADDITIONAL COST TO THE OWNER. ' DN RETURN &EXHAUST DUCT SECTION (DOWN) 18. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BIDDING, ORDERING, .� RETURN AIR FABRICATION OR INSTALLATION OF MATERIALS OR EQUIPMENT. ° �3 -AV DOOR UNDER CUT crrilii' L � 19• NO COMBUSTIBLE MATERIALS ARE ALLOWED IN RETURN AIR PLENUMS OR ABOVE -� SUPPLY AIR °� ®` vl'r'" CEILINGS USED AS RETURN AIR PLENUM. IF SPACE WITH RETURN AIR PLENUM J ruccural A AD - ACCESS DOOR HAS ANY DECK TO DECK PARTITIONS, AIR TRANSFER DUCTS MUST BE INSTALLED. ir�ricai � 20. THIS IS A REMODEL OF AN EXISTING SPACE. CONTRACTOR TO VISIT SITE PRIOR TO BID. e DUCT SMOKE DETECTOR NOT ALL SYMBOLS MAY 5 &Z k APPLY TO THEM PLANS F orestLr Fire u� � 3 Police Other @ Pracv >sd I #11S or!< invc orn this permit =,jall conform tivith all v4) oynton Beach 13aiildin _ Os - NO TH MECHANICAL FLOOR PLAN s . s S C A L E: 1/4 1 1 ABBREVIATION AFF ABOVE FINISH FLOOR F/A FRESH AIR AHU AIR HANDLING UNIT GPM GALLONS PER MINUTE CD CONDENSATE DRAIN GR GRILLE CD CEILING DIFFUSER MCA MINIMUM CIRCUIT AMPS (FOR WIRE SIZING) CU CONDENSING UNIT MOCP MAXIMUM OVERCURRENT PROTECTION DEVICE AMPS EWT ENTERING WATER TEMPERATURE LWT LEAVING WATER TEMPERATURE EAG EXHAUST AIR GRILLE R/A RETURN AIR EF EXHAUST FAN REG REGISTER EXH EXHAUST SP SAFE PAN FSD FIRE SMOKE DAMPER VCD VOLUME CONTROL DAMPER AD ACCESS DOOR RAG RETURN AIR GRILLE FD FIRE DAMPER SAR SUPPLY AIR REGISTER 0/A OUTSIDE AIR I #11S or!< invc orn this permit =,jall conform tivith all v4) oynton Beach 13aiildin _ Os - NO TH MECHANICAL FLOOR PLAN s . s S C A L E: 1/4 1 1 5� t ' _ g ' F-� �a > :: °`'' D izz .. ,. ey- , 5� t Q a �G a 'x w �x o � o °z �� H O m 0 v DRAWN RRY CHECKED RRY DATE FEB. 4TH 2015 SCALE AS SHOWN JOB NO. 15 -005 SHEET TITLE MECHANICAL FLOOR PLAN SHEET NO. z M1 OF ' _ g ' w` �a Q a �G a 'x w �x o � o °z �� H O m 0 v DRAWN RRY CHECKED RRY DATE FEB. 4TH 2015 SCALE AS SHOWN JOB NO. 15 -005 SHEET TITLE MECHANICAL FLOOR PLAN SHEET NO. z M1 OF rev. descripEion I 6y I date 01 o� .el*' SHUT OFF VALVES REQUIRED ON ALL DOWN FEED SUPPLY LINES TO FIXTURES. PLUMBING WATER ISOMETRI SCALE: N.T.S O CONNECT P WASTE DRAI ELBOW DN. P -TRAP TO LINE USING (TYP.) SEAL L L 1 1" L z ri Z L L Y 7 L x NO PLUMBING SANITARY ISOMETR SCALE: N.T.S PLUMBING WATER PLAN SCALE: 114' =1' —O' PLUMBING SANITARY PLAN SCALE: 1le4 -0' NO € f 2 # WATER HAMMER ARRESTOR REQUIRED BUT NOT SHOWN (TYPICAL AT ALL SUPPLY LINE TO FIXTURES) ALL PLUMBING FIXTURES, FIXTURE FITTINGS AND APPLIANCES TO BE HIGH EFFICIENCY mf € € 3 m o 4 �.........._— 1 € 1X2 date: ® 3LF a-j C + m _W_ Cw 2�S 2"S ! W 58TH AVE sheet: N 4 V RYEH IAO MYACC. N E' cu I ° 0 EXISTING BATH ROOM TO REMAIN AS IS NO WORK THIS AREA * FLORIDA LICENSE #64833 CERT. OF AUTH. #27 ; PROJECT E C 1 /2 " CW, HW CONNECT TO EXISTING CW LINE. AND POINT OF CONNECTION. #15 -0 +0 o c LL CONTRACTOR TO VERIFY LOCATION U) O c -c w 3/4 CW, HW rL E COPY ® O CONNECT TO EXISTING SEWER LINE BEYOND BATH ROOM GROUP DIVISION 2 SAN DN z o CONTRACTOR TO VERIFY LOCATION AND POINT OF CONNECTION LLJ o 2° VENT UP TO 4 I o c � ( ABOVE CEILING o 2 S ( 4 CONNECT TO EXISTING VENT LINE CONTRACTOR TO VERIFY LOCATION AND POINT OF NEW CONNECTION I n 3 S E CW, HW z� PROVIDE FD PRIMER, SEE DETAIL, tU O 1l o �fL PLUMBING WATER ISOMETRI SCALE: N.T.S O CONNECT P WASTE DRAI ELBOW DN. P -TRAP TO LINE USING (TYP.) SEAL L L 1 1" L z ri Z L L Y 7 L x NO PLUMBING SANITARY ISOMETR SCALE: N.T.S PLUMBING WATER PLAN SCALE: 114' =1' —O' PLUMBING SANITARY PLAN SCALE: 1le4 -0' NO drawn by mf m o J. Biagi date: 07 -16 -14 C m YY® CONSUL NTS INC ° lob no: ! W 58TH AVE sheet: N 4 V RYEH IAO MYACC. N E' cu I ° 0 w * FLORIDA LICENSE #64833 CERT. OF AUTH. #27 ; PROJECT E C W #15 -0 0 c LL W U) O c -c w RE VISION rL E COPY BIJILDIN DIVISION z o V o ()) .— � o c � ( o drawn by mf checked by: J. Biagi date: 07 -16 -14 YY® CONSUL NTS INC ° lob no: ! W 58TH AVE sheet: 4 SPRINGS FL 33067 F (954) 263 -9318 RYEH IAO MYACC. N E' I ° RAMZI R. YEHIA W * FLORIDA LICENSE #64833 CERT. OF AUTH. #27 ; PROJECT #15 -0 2015 m IL, 2 RE VISION rL E COPY BIJILDIN DIVISION PLUMBING LEGEND P I FIXTURE SANITARY SEWER PIPING - - - -� VENT PIPING - - - -$ DOMESTIC COLD WATER PIPING 4- - - - HOT WATER PIPING (110 °) - -� OXYGEN PIPING �- - - - SCAVENGING SYSTEM L-1 CHECK VALVE 2" BALL VALVE O OXYGEN CEILING DROP CO /CTG CLEAN OUT /CLEAN OUT TO GRADE CW DOMESTIC COLD WATER HW DOMESTIC HOT WATER HWR HOT WATER RETURN SAN SANITARY LS LAUNDRY SINK HS HAND SINK KS KITCHEN SINK HB W /VB HOSE BIB W /VACUUM BREAKER WC WATER CLOSET LAV LAVATORY W WASHER AAV AUTOMATIC AIR VENT (STUD ❑R) ❑2 OXYGEN SCAV SCAVENGING PLUMBING LEGEND P I FIXTURE ROUGH -IN SIZES TO FIXTURES UNLESS OTHERWISE SHOWN ON PLANS COLD WATER HOT WATER TRAP WASTE/ VENT WATER CLOSET 1/2" - 3" 2" URINAL 3/4" - 2" 2" LAVATORY 1/2" 1/2" 1 -1/4" 2" MOP SINK 3/4" 3/4" 3" 2" SINK (SINGLE COMPARTMENT) 1/2" 1/2" 1 -1/2" 2" DRINKING FOUNTAIN 1/2" - 2" 2" SHOWER 1 /2 - 1 /2 - 2" 2" EYE WASH 1/2" 1/2" 1 -1/2a 2" HOSE BIBB 3/4" - - - TRAP PRIMER 1/2" - - - FLOOR DRAIN - - 3" 2" WALL CLEAN OUT - - MATCH PIPE - GRAND CLEAN OUT - - MATCH PIPE - P2 PLUMBING NOTES 1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE LOCAL CODES, RULES AND ORDINANCES. 2. PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 3. ALL MATERIALS SHALL BE NEW. 4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. ALL EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF THIS CONTRACT. 5. REQUIRED INSURANCE SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 6. PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTION AND TESTS, PLUMBING CONTRACTOR TO OBTAIN PERMIT AND APPROVED SUBMITTALS PRIOR TO BEGINNING WORK OR ORDERING EQUIPMENT. PLUMBING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS OF HIS WORK BY REGULATORY AUTHORITIES. 7. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC. 8. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPANCY TO ENGINEER /ARCHITECT PRIOR TO BEGINNING CONSTRUCTION. 9. VERIFY LOCATION, SIZE, DIRECTION OF FLOW AND INVERTS OF ALL EXISTING UTILITIES PRIOR TO BEGINNING OF CONSTRUCTION. ADVISE ENGINEER OF ANY DISCREPANCIES. 10. WATER DISTRIBUTION PIPING ABOVE GROUND SHALL BE TYPE "L" COPPER. WATER DISTRIBUTION PIPING BELOW GROUND IN DADE AND BROWARD COUNTIES SHALL BE TYPE "L" COPPER, ALL OTHER COUNTIES SHALL BE TYPE "M" COPPER. 11. SOIL, WASTE, VENT AND RAINWATER PIPING AND FITTINGS SHALL BE PVC SCHEDULE 40. 12. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPS AND APPROPRIATELY MARKED ACCESS PANELS. COORDINATE LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO INSTALLATION. 13. FURNISH AND INSTALL APPROVED AIR CHAMBERS, AT EACH PLUMBING FIXTURE AND APPROVED SHOCK ARRESTORS ON MAIN LINES OR RISERS. 14. DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS. 15. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PAD. 16. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM FIRE, SMOKE AND WATER PENETRATION BY FILLING VOIDS BETWEEN PIPE AND WALL /FLOOR SLEEVES WITH FIRE RATED FOAM, TO ACHIEVE THE SAME RATING AS WALLS OR FLOORS AS PART OF THE PLUMBER'S WORK. 17. PLUMBING CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE BY OWNER. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED. 18. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES AND ALL WATER HAMMER ARRESTERS. ACCESS PANELS IN RATED WALLS MUST MAINTAIN THE SAME RATING AND MUST MATCH THE FINISH OF THE WALL IN WHICH IT IS INSTALLED. 19. PROVIDE CHROME PLATED COMBINATION COVER PLATE AND CLEANOUT PLUG OR ACCESS PANEL FOR ALL WALL CLEANOUTS. 20. NO COMBUSTIBLE MATERIAL TO BE USED IN MECHANICAL ROOMS OR IN CEILING SPACES WHERE USED AS RETURN AIR PLENUMS. 21. NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN ELECTRICAL OR ELEVATOR EQUIPMENT ROOMS. 22. ALL CONTROL VALVES SHALL BE TAGGED AND MARKED. A REPRODUCABLE DIAGRAM LOCATING ALL VALVES SHALL BE PROVIDED FOR OWNER /OPERATOR. 23. ALL CONDENSATE DRAIN PIPING SHALL BE TYPE "L" COPPER WITH 1" THICK ARMAFLEX INSULATION WHERE USED IN A RETURN AIR PLENUM. PVC PIPING WITH 1" THICK ARMAFLEX INSULATION MAY BE USED IN LOCATIONS WHERE ALLOWED BY LOCAL CODES. SEE PLUMBING DRAWINGS FOR SIZE AND LOCATION OF PIPING. 24. PROVIDE ANGLE STOPS ON ALL WATER SERVICE LINES TO FIXTURES FOR INDIVIDUAL SHUT -OFF. 25. STUDOR MINI /MAXI AIR ADMITTANCE VALVES MAY BE USED AS AN ALTERNATE TO VENT PIPING THRU ROOF WHERE ACCEPTABLE BY THE PLUMBING OFFICIAL AND LOCAL CODES. INSTALLATION SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS. PLUMBING FIXTURE SCHEDULE. I P3 SEE FLOOR PLAN FOR CONTINUATION --- -- - - - - -- cw DIELECTRIC PIPE UNI ❑N (TYPICAL) THERMOMETE1 HEAT TRAP HEAT TRAP INTEGRAL P� WITH HEATEI DIELECTRIC PIPE UNION EXPANSION TANK PR ❑VIDE NECESSARY SUPPORT FROM BUILDING STRUCTURE. -INSTALL AT LOCATION FOR INSPECTION AND SERVICE. HEAT TRAP (OMIT IF -HEAT TRAP IS AN INTEGRAL PART FURNISHED WITH HEATE - SHUT -OFF VALVE (TYPICAL) 3INATION PRESS, VE MP, RELIEF GAP FITTING, J.R. TH FIG. 3905T RAIN VALVE FULL SIZE RELIEF VALVE LINE TO SPILL OVER FLOOR DRAIN. WATER SUPPLY TO LAVATORY, SINK AND SIMILAR TYPE FIXTURES AND EQUIPMENT. WATER HAMMER ARRESTOR" PPI MODEL 50OLS WALL \.. MAY EXTEND AS A WASTE OR VENT I WATER SYSTEM NOTES: FOR CLARITY, NOT ALL THE FOLLOWING WORK, DEVICES, AND APPURTENANCE MAY BE SHOWN, ON CONTRACT DRAWINGS OR SPECIFIED. HOWEVER ALL SHALL BE FURNISHED AND INSTALLED AS AND WHERE REQUIRED. 1. SHUT OFF VALVE ON HOT WATER AND COLD BRANCH SUPPLY TO EACH PLUMBING FIXTURES. 2. SHUT OFF VALVE ON COLD BRANCH SUPPLY TO EACH WALL HYDRANT AND HOSE BIBB. 3. SHUT OFF VALVE ON WATER SUPPLY TO EACH APPLIANCE AND MECHANICAL EQUIPMENT. 4. ANGLE VALVE, SUPPLY STOPS AND CONNECTION TO FIXTURES AND EQUIPMENT. 5. WATER HAMMER ARRESTOR ON ALL WATER SUPPLY LINES SERVING, PLUMBING FIXTURES, SOLENOID VALVES, ETC. INCLUDING OTHER FIXTURES OR EQUIPMENT WITH QUICK CLOSING VALVES. REFER TO DETAIL "WATER HAMMER ARRESTOR" FOR ADDITIONAL INFORMATION. PROVIDE ACCESS TO EACH WATER HAMMER ARRESTOR, UNLESS OTHERWISE DIRECTED BY CODE OFFICIAL. 6. REFER "PLUMBING CONNECTION SCHEDULE" AND "GENERAL PLUMBING NOTES" ON FOOD SERVICE DRAWINGS, INCLUDING EQUIPMENT DATAT SHEETS, AND MANUFACTORIES RECOMMENDATIONS FOR LOCATION AND RECOMMENDED PLACEMENT OF BACKFLOW PREVENTOR, VACUUM BREAKER, PRESSURE REDUCING VALVE, SOLENOID VALVE, SOLENOID VALVE, WATER FILTER, ETC. ON WATER SUPPLY LINES TO FIXTURES AND EQUIPMENT REQUIRING SUCH DEVICES. PROVIDE ALL OF THE ABOVE REFERENCED ITEMS UNLESS FURNISHED WITH EQUIPMENT. 7. PROVIDE AUTOMATIC TRAP PRIMER ON COLD WATER CONNECTION TO LAVATORY FIXTURE WITH COLD WATER TUBE TO FLOOR DRAIN AUXILIARY INLET FITTING. ALSO PROVIDE AUTOMATIC TRAP PRIMER WITH COLD WATER TUBE CONNECTION TO OTHER FLOOR DRAINS WHICH DO NOT RECEIVE INDIRECT WASTE CONNECTION. SANITARY/ WASTE SYSTEM NOTES: 1. ALL SANITARY PIPING 2" AND LESS SHALL SLOPE Y4" PER FOOT. 2. UNLESS OTHERWISE DIRECTED AN /OR SPECIFED ON CONTRACT DOCUMENTS, ALL PLUMBING FIXTURES, TRIM, DEVICES, APPURTENANCE TO BE FURNISHED BY THIS CONTRACT. 3. A. FURNISH AND INSTALL PLUMBING ROUGHING AND CONNECTION TO ALL KITCHEN FIXTURES AND EQUIPMENT, INCLUDING FIXTURES AND EQUIPMENT NOTED IN PARAGRAPH 2 ABOVE, AND /DR SPECIFIED IN THESE DOCUMENTS. B. INSTALLATION SHALL CONSIST OF TRAPS, SUPPORTS, FLOOR SINKS, FLOOR DRAINS, FUNNEL DRAINS, INDIRECT WASTE, ETC. AND NECESSARY ROUGHING FOR A COMPLETE OPERATING SYSTEM, CODE APPROVED AND AN INSTALLATION ACCEPTABLE TO THE ARCHITECT. 4. SANITARY /VENT PIPING AND WATER PIPING SHALL WHERE POSSIBLE BE INSTALLED (CONCEALED FROM VIEW) IN WALLS, IN SOFFITS ABOVE CABINETS, AND ABOVE DROP CEILINGS. NOTIFY ARCHITECT FOR DIRECTION IF FIELD CONDITIONS REQUIRE WORK OR MODIFICATION TO THE PROPOSED INSTALLATION TO HIDE PIPING. 5. WASTE FROM KITCHEN EQUIPMENT AND FIXTURES WHEN NOTED OR SPECIFIED SHALL DISCHARGE TO WAST RECEPTOR THROUGH AN INDIRECT PIPE BY MEANS OF AN AIR GAP. INDIRECT WASTE PIPING EXCEEDING 24" HORIZONTAL OR 48" IN TOTAL LENGTH SHALL BE INSTALLED WITH TRAP. 6. REFER "PLUMBING CONNECTION SCHEDULE" AND "GENERAL PLUMBING NOTES" ON FOOD SERVICE DRAWINGS INCLUDING EQUIPMENT DATA SHEETS FOR RECOMMENDED PLACEMENT OF WASTE RECEPTOR, FLOOR SINKS, FLOOR DRAINS, TROUGH DRAIN, AND HUB DRAINS, INCLUDING INDIRECT WASTE CONNECTIONS FROM FIXTURES AND EQUIPMENT. REFER TO PLUMBING DOCUMENTS FOR TYPE OF WASTE RECEPTOR AND DRAINS. 7. SEE SITE PLAN FOR CONTINUATION OF SANITARY BUILDING SEWER. REFER TO PROJECT NOTES FOR ADD111ONAL WORK AND REQUIREMENTS. & SCREW WALL CHROME WALLC❑VER PLUGGED TEE W/ CLEANOUT FLOOR LINE 1/8' BEND TYPE - A (INDIVIDUAL FIXTURE) WATER HEATER: WATER DETAIL WATER HAMMER ARRESTOR P4 N.T.S. PS N.T.S. BALANCE OF PIPING SAME AS CLEANOUT TO GRADE, P 6 WALL CLEANOUT DETAIL N.T.S. PR ❑VIDE AN INDIVIDUAL VENT ON ALL FLOOR DRAINS. INSTALL VENT IN PARTITION OR CHASE WHERE SHOWN ON PLAN, HORIZONTAL VENT BELOW FLOOR IS NOT PERMITTED. OTHER VENTING METHODS MAY BE USED IF APPROVED BY LOCAL CODE, I a 4I. { / -' MAXIMUM 15' WHERE ENLARGED WASTE LINE IS USED AS A COMBINATI ❑N WASTE AND VENT SYSTEM. PR ❑VIDE TRAP PRIMER IF RE- QUIRED BY LOCAL AUTHORITIES. OTHERWISE DEEP -SEAL P -TRAP CONCRETE FLO❑ MEMBRANE CLAMP- ING COLLAR AND SEEPAGE PAN MAXIMUM TAILPIECE LENGTH IS 2 FEET ;� SLOPE WASTE AT TW❑ PERCENT MAX.15' ON 3' WAS LOCATE FLOOR DRAINS WHERE SHOWN ON DIMENSIONED ARCHITEC- TURAL PLAN. IF FLOOR STRUCTURE INTERFERES WITH FLOOR DRAIN, MOVE SIDEWAYS IF POSSIBLE, OTHERWISE MOVE BACK. ALWAYS LOCATE WHERE EASILY ACCESSIBLE, BUT NOT IN FOOT TRAFFIC, IF SITUATI ❑N IS FLOOR SLAB ON GRADE, PROVIDE BACKFILL PER SPECIFICATIONS. IF CONCRETE FLOOR IS NOT EXISTING, SET DRAIN IN PLACE AND POUR AROUND IT. IF CONCRETE FLOOR IS EXISTING, SAW CUT OR CORE DRILL IT, SET DRAIN BODY IN PLACE AND POUR AROUND IT. RECESS TOP OF FLOOR DRAIN 1/2' BELOW FLOOR SURFACE AND SLOPE FLOOR TO IT, I FLOOR DRAIN DETAIL P 7 N.T.S. rev. description ^\ 04/28/2015 ' \ SAS built re6ion GENERAL NOTES A a) INSTALLATION OF WORK AND NEW CONNECTION TO EXISTING PLUMBING LINES SHALL BE MADE AT TIME WHICH WILL NOT INTERFER OR INTERRUP THE NORMAL BUILDING OPERATION. b) CONSULT WITH BUILDING RULES AND REGULATION REGARDING USE OF ELEVATOR, MATERIALS IN AND OUT OF BUILDING, WORKING HOURS, AND OTHER CONDITIONS AFFECTING THE WORK OF THIS PROJECT. c) EXACT LOCATION, SIZE, AND ROUTING OF PIPING WITHIN WALLS AND DROP CEILING SHALL BE FIELD VERIFIED BEFORE START OF WORK. d) PROVIDE NESCESSARY ADJUSTMENT OF NEW INSTALLATION DUE TO INIERFEREANCE WITH BUILDING CONDITIONS, INCLUDING NEW AND EXISTING PIPING. e) PIPING MATERIAL, VALVES, PIPE SUPPORTS, PIPE SLEEVES, ETC. USED IN THE INSTALLATION OF WORK OF THIS CONTRACT SHALL BE NEW AND SHALL MATCH EXISTING, PROVIDING IT MEETS ALL APPLICABLE BUILDING AND PLUMBING CODES. B a) REFER TO ARCHITECT DOCUMENTS FOR ADDITIONAL REQUIREMENTS RELATIVE TO WORK OF THIS PROJECT. b) EXISTING WASTE, SOIL, AND HOT / COD WATER ROUGHING SHALL BE REVISED AS REQUIRED FOR THE INSTALLATION OF THE NEW PLUMBING AND PIPING. c) PROVIDE NEW ROUGHING TO PLUMBING FIXTURES, IF NECESSARY PLUMBING CONNECTIONS ARE FOUND DAMAGED, OR MISSING. d) DRAWING OF EXISTING TENANT AND BASE BUILDING PLUMBING WORK IS NOT AVAILABLE. THEREFOR ROUTING OF PIPING, SIZE, AND POINT OF CONNECTION IS BASED ON ASSUMPTION THAT EXISTING PIPING IS AT LOCATION SHOWN, OR NOTED ON PLAN. e) LOCATION, SIZE, AND ELEVATION OF EXISTING PIPING MALL BE FIELD VERIFIED BEFORE START OF WORK. ACTUAL FIELD GONDIONS MAY REQUIRE ADJUSTMENT OR MODIFICATION TO PROPOSED ROUGHING, LAYOUT, AND ROUTING OF PIPING, INCLUDING POINT OF CONNECTION. f) EXISTING PIPING SHALL BE MODIFIED AND /OR REMOVED TO POINT THAT WOULD ACCOMMODATE CONNECTION OF NEW (WATER, WASTE, SOIL, VENT) PLUMBING ROUGHING. g) ALL PIPE SUPPORTS SHALL BE HOT DIP GALVANIZED, CONSISTING OF ADJAJSTABLE CLEVIS HANGERS. HANGER ROD SHALL BE SECURED TO BUILDING STRUCTURE. EXISTING NOTE: A. CONTRACTOR SHALL VERIFY THE LOCATIONS OF EXISTING SANITARY, CW, HW LINES AND SHALL CONNECT THE NEW PIPING TO THE EXISTING SYSTEM AS SHOWN ON THIS PLAN, MOREOVER CONTRACTOR SHALL VERIFY THE TYPE OF THE EXISTING MATERIAL AND SANITARY, CW /HW LINES AND SHALL MATCH THE SAME FOR NEW PIPING. B. REFER TO CONTRACT DOCUMENTS FOR ADDITIONAL WORK, SIZES, INFORMATION, ETC. REGARDING THE ISTALLATION OF PLUMBING SYSTEMS FOR THIS PROJECT. IN THE EVENT OF DESCREPANCIES THE MOST STRINGENT OF THE REQUIREMENTS WILL GOVERN. 6y I date Imm mmmm l l ll C U. a HOT OR COLD WATER TO PLUMBING FIXTURE PIPE CLAMP WITI• TRISOLATOR M ❑UP TOP PLATE TO CHANNEL OR STEEL OR WOOD STN. 5`0' DIS WASTE OR VENT WIRED TO STEEL - CHANNEL FIN, FL❑ ❑R m > 0 _0 I � 9D U J ; ­ 2 jX N o m E lLj n�7 C m m e 4) / � L.L. o ( IJ ° L. v J ��D Imm mmmm l l ll C U. a HOT OR COLD WATER TO PLUMBING FIXTURE PIPE CLAMP WITI• TRISOLATOR M ❑UP TOP PLATE TO CHANNEL OR STEEL OR WOOD STN. 5`0' DIS WASTE OR VENT WIRED TO STEEL - CHANNEL FIN, FL❑ ❑R • I 11111 m PIPE DROP IN STUD WALT N.T.S. ' W 0 0 z PLUMBING NOTES WATER HAMMER ARRESTOR PPI MODEL 50OLS INSTALLED ABOVE DROP CLG, OR OTHER ACCESSIBLE LOCATI ❑N. WATER SUPPLY TO WATER CLOSETS, URINALS, AND SIMILAR TYPE FIXTURES, TYPE - B (INDIVIDUAL FIXTURE) .12 WIDE 16 GA ANNEL BOLTED ILED TO STUD PROVED MANNER P' 1/2' SHOCK 'ESTOR DROP ELL SCR =EL CHANNEL A: FH FELT IN BE1 FERNATE SUPPL :ATION 5F a > _0 I � 9D U E C m J 4) / � L.L. p ° L. v J 0 z MM MM ( D U o O O 4-j C Q 0 � O r' Q W drawn by: mf checked by: J. Biagi date: 07 -16 -14 • I 11111 m PIPE DROP IN STUD WALT N.T.S. ' W 0 0 z PLUMBING NOTES WATER HAMMER ARRESTOR PPI MODEL 50OLS INSTALLED ABOVE DROP CLG, OR OTHER ACCESSIBLE LOCATI ❑N. WATER SUPPLY TO WATER CLOSETS, URINALS, AND SIMILAR TYPE FIXTURES, TYPE - B (INDIVIDUAL FIXTURE) .12 WIDE 16 GA ANNEL BOLTED ILED TO STUD PROVED MANNER P' 1/2' SHOCK 'ESTOR DROP ELL SCR =EL CHANNEL A: FH FELT IN BE1 FERNATE SUPPL :ATION 5F a YMI CONSULTANTS, INC. job no: sheet: 5516 NW 5 VE CORAL SP 33I TEL 263 -9318 °. ®MYACC.NET 11 A RAE17.i R VF!WA P2 > _0 � U E C m J 4) / � L.L. p ° L. v J 0 z MM MM ( D U o O O 4-j C Q 0 � O r' Q W drawn by: mf checked by: J. Biagi date: 07 -16 -14 YMI CONSULTANTS, INC. job no: sheet: 5516 NW 5 VE CORAL SP 33I TEL 263 -9318 °. ®MYACC.NET 11 A RAE17.i R VF!WA P2 d department comments MECHANICAL NOTES 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY FOR THE INSTALLATION OF A COMPLETE SYSTEM IN ACCORDANCE WITH THESE DRAWINGS, THE APPLICABLE BUILDING CODE AND ALL OTHER APPLICABLE STATE, COUNTY AND LOCAL ORDINANCES AND THE LATEST ADDITION OF THE FOLLOWING PUBLICATIONS; SMACNA, ASHRAE, NFPA 90A, 90B, 91 & ANSI B -9.1 MECHANICAL REFRIGERATION. 2. THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK. 3. THE CONTRACTOR SHALL VISIT THE SITE AND COORDINATE WORK WITH OTHER TRADES. 4. THE CONTRACTOR SHALL SUPPLY THE ARCHITECT WITH "AS- BUILT" DRAWINGS. 5. CONTRACTOR SHALL SUBMIT, FOR APPROVAL FIVE [5] COPIES °OF MANUFACTURER'S DRAWINGS FOR EACH PIECE OF EQUIPMENT AND CONTROLS INCLUDED IN CONTRACT. 6. ALL MATERIAL SHALL BE NEW OF U.S. MANUFACTURER OF GOOD QUALITY. ALL WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER BY SKILLED WORKMAN. 7. ALL AIR CONDITIONING DUCT WORK SHALL BE OF 1-1/2" (R -6) STANDARD DUTY FOIL REINFORCED FIBERGLASS WITH MANUFACTURER'S LOGO PRINTED ON VAPOR BARRIER ALL FLEX TO BE R -6. 8. ALL EXHAUST DUCTS AND OUTSIDE AIR DUCTS SHALL BE GALVANIZED SHEET METAL WITH SEALED SEAMS AND JOINTS. 9. DUCT SIZES SHOWN ARE INSIDE DIMENSIONS. 10. ALL AIR DEVICES (DIFFUSERS, REGISTERS AND GRILLES) SHALL BE ALL ALUMINUM CONSTRUCTION WITH EXPOSED SURFACE OFF WHITE BAKED ENAMEL FINISH TO MATCH EXISTING OR AS SPECIFIED BY ARCHITECT. DEVICES SHALL BE TITUS, METALAIRE, AIRGUIDE. PROVIDE OPPOSED BLADE DAMPERS AT ALL DIFFUSERS AND REGISTERS. 11. THERMOSTAT SHALL BE COMBINATION COOLING /HEATING, WITH SYSTEM "COOL -AUTO- HEAT -OFF" AND FAN "ON -AUTO" SELECTOR SWITCHES. PROVIDE PROGRAMMABLE TYPE, �IQ� I� E�E1� ILEA Fb�OXLZE AT4MftWfflW GCM5KQ ENT BEFORE STARTING 12. THEM. REPLACE THEM PRIOR TO FINAL ACCEPTANCE BY OWNER. 13. PROVIDE SMOKE DETECTORS WITH ACCESS DOORS IN ALL SUPPLY AIR DUCTS FOR FANS AND AHU'S SERVING A COMMON PLENUM OF 2000 CFM OR ABOVE. ALL SMOKE DETECTORS SHALL BE BY ONE MANUFACTURER, COORDINATE-VOLTAGE ETC, WITH ELECTRICAL CONTRACTOR AND FIRE ALARM SYSTEM BEFORE ORDERING. UPON DETECTION, SMOKE DETECTORS SHUT DOWN ASSOCIATED AIR MOVING EQUIPMENT AND ALL AIR MOVING EQUIPMENT SERVING THAT COMMON PLENUM. 14. PROVIDE TYPE "B" FIRE DAMPERS IN ALL DUCTS OR OPENINGS PENETRATING FIRE RATED WALLS, MECHANICAL AND ELECTRICAL EQUIPMENT ROOMS, TENANT SEPARATION, PARTITIONS, FLOOR OR ROOF SLABS AND AT O/A INTAKES. PROVIDE RADIATION RADIATION DAMPERS IN RATED CEILINGS FOR ALL CEILING OPENINGS, CEILING FANS, DIFFUSERS OR GRILLES RATED FOR USE IN THE CEILING ASSEMBLY. 15. THERMOSTAT LOCATION SHALL BE APPROVED BY OWNER AND ENGINEERS BEFORE INSTALLATION. 16. PROVIDE A MIN. OF 3' CLEARANCE IN FRONT OF ALL 120 -240 VOLT PANELS AND 4' CLEARANCE IN FRONT OF ANY 480 VOLT PANEL. PROVIDE ADEQUATE SIDE CLEARANCE PER NEC. 17• MECHANICAL PLANS IN GENERAL, ARE DIAGRAMMATIC IN NATURE, AND ARE TO BE READ IN CONJUNCTION WITH ARCH. PLUMBING, ELECTRICAL AND STRUCTURAL PLANS AND SHALL BE CONSIDERED AS ONE SET OF DOCUMENTS, DUCT AND PIPING OFFSETS, BENDS AND TRANSITIONS WILL BE REQUIRED TO PROVIDE AND INSTALL A COMPLETE FUNCTIONAL SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 18. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO' BIDDING, ORDERING, FABRICATION OR INSTALLATION OF MATERIALS OR EQUIPMENT. 19. NO COMBUSTIBLE MATERIALS ARE ALLOWED IN RETURN AIR PLENUMS OR ABOVE CEILINGS USED AS RETURN AIR PLENUM. IF SPACE WITH RETURN AIR PLENUM HAS ANY DECK TO DECK PARTITIONS, AIR TRANSFER DUCTS MUST BE INSTALLED. 20. THIS IS A REMODEL OF AN EXISTING SPACE. CONTRACTOR TO VISIT SITE PRIOR TO BID. mi I MECHANICAL NOTES DESIGN REQUIREMENTS REQUIRED DUCT SMOKE DETECTOR NO FIRE DAMPER(S) NO SMOKE DETECTOR NO FIRE RATED ENCLOSURE NO FIRE RATED ROOF/FLOOR NO FIRE ST ❑PING NO SMOKE CONTROL NO M r1 G HVAC DESIGN REQUIREMENTS AFF LEGEND NEW SUPPLY AIR CEILING DIFFUSER FRESH AIR NEW RETURN AIR CEILING GRILLE AIR HANDLING UNIT WALL LOUVER / WALL DIFFUSER. GALLONS PER MINUTE FIRE DAMPER, ALL FIRE DAMPERS CONDENSATE DRAIN SHALL BE FIRE SMOKE DAMPERS GRILLE `a FIRE SMOKE DAMPER CEILING DIFFUSER VOLUME CONTROL DAMPER MINIMUM CIRCUIT AMPS (FOR WIRE SIZING) QQ THERMOSTAT CONDENSING UNIT QQ HUMIDISTAT MAXIMUM OVERCURRENT PROTECTION DEVICE AMPS NEW FLEX DUCT ENTERING WATER TEMPERATURE NEW DUCTWORK LEAVING WATER TEMPERATURE - SUPPLY TOP REGISTER (WALL TYPE) EXHAUST AIR GRILLE RETURN OR EXHAUST TOP REGISTER RETURN AIR OR GRILLE WALL TYPE (AIR INTO EXHAUST FAN DEVICES) REGISTER INCLINED RISE IN DIRECTION EXHAUST OF AIR FLOW, FLAT BOTTOM SAFE PAN INCLINED DROP IN DIRECTION FIRE SMOKE DAMPER OF AIR FLOW, FLAT BOTTOM VOLUME CONTROL DAMPER DIFFUSER OR GRILLE DESIGNATION ACCESS DOOR ROOF EXHAUST FAN RETURN AIR GRILLE Ef OR EF EXHAUST FAN FIRE DAMPER offi FLEXIBLE CONNECTION SUPPLY AIR REGISTER �-- FC DUCT TURN WITH TURNING VANES OUTSIDE AIR - PROVIDE ALL SQUARE OR RECTANGULAR ELBOWS WITH VANES EVEN IF SYMBOL IS MISSING STANDARD RADIUS ELBOW, ROUND DUCT ALL SQUARE OR RECTANGULAR ELBOWS WITH VANES EVEN IF SYMBOL IS MISSING. ®UP SUPPLY & OUTSIDE AIR SECTION (UP) 3 DN SUPPLY & OUTSIDE AIR SECTION (DOWN) UP RETURN & EXHAUST DUCT SECTION (UP) DN RETURN & EXHAUST DUCT SECTION (DOWN) -A C RETURN AIR •\ru /c DOOR UNDER CUT -► SUPPLY AIR AD - ACCESS DOOR Z DUCT SMOKE DETECTOR NOT ALL,SYMWLS MAY APPLY TO THESE PLANS AFF ABOVE FINISH FLOOR F/A FRESH AIR AHU AIR HANDLING UNIT GPM GALLONS PER MINUTE CD CONDENSATE DRAIN GR GRILLE CD CEILING DIFFUSER MCA MINIMUM CIRCUIT AMPS (FOR WIRE SIZING) CU CONDENSING UNIT MOCP MAXIMUM OVERCURRENT PROTECTION DEVICE AMPS EWT ENTERING WATER TEMPERATURE LWT LEAVING WATER TEMPERATURE EAG EXHAUST AIR GRILLE R/A RETURN AIR EF EXHAUST FAN REG REGISTER EXH EXHAUST SP SAFE PAN FSD FIRE SMOKE DAMPER VCD VOLUME CONTROL DAMPER AD ACCESS DOOR RAG RETURN AIR GRILLE FD FIRE DAMPER SAR SUPPLY AIR REGISTER O/A OUTSIDE AIR MECHANICAL/HVAC LEGEND & M3 ABBREVIATION; N.T.S. INTERLOCK EF WITH AN OVEF SO, THAT EF- WHEN RTU -1 AND OVERRIDI ALLOW TURNIP 1. RUN DUCT BE AND THEN TO THREE LOCATI CONNECT TO 2. FROM EF -2 T 3. INSURE MINIMI OUTSIDE AIR `. 4. PROVIDE 6 (6 EACH SIDE OF BETWEEN CHAT 5. COORDINATE C LOCATION WITI MECHANICAL FLOOR PLAN • 0 w z O U 1`_� Q Q 9 a � U �U w� m z ca o 3� M O V I DRAWN R CHECKED RRY DATE. FEB. 4TH 2015 SCALE AS SHOWN JOB NO. 15 -005 SHEET TITLE MECHANICAL FLOOR PLAN APR S ET NO. 201 z M I EVE O P� BUILDING NISI I GENERAL CONSTRUCTION NOTES 1. THE INTENT OF THESE DOCUMENTS IS `TO INCLUDE ALL WORK AND ITEMS NECESSARY FOR THE COMPLETION OF THE WORK. THEREFORE, ALL ITEMS NECESSARY FOR THE COMPLETION OF THE WORK SHALL BE REQUIRED WHETHER OR NOT SHOWN ON THE PLANS AND /OR CONSTRUCTION DOCUMENTS BUT ARE REASONABLY INFERABLE AS BEING NECESSARY TO PROVIDE THE INTENDED RESULTS. 2. THE CONTRACTOR IS REQUIRED TO VERIFY ALL DIMENSIONS - DO NOT SCALE DRAWINGS. 3. ALL MATERIALS SHALL BE NEW. 4. ALL WORK SHALL BE OF THE HIGHEST QUALITY FOR THE TRADE INVOLVED WITH THE ARCHITECT HAVING THE LAST SAY AS TO QUALITY. 5. THE GENERAL CONTRACTOR OR ANY SUBCONTRACTORS SHALL CLEARLY LIST ON HIS BID ANY WORK NOT INCLUDED. 6. ALL WORK AND MATERIALS SHALL BE GUARANTEED FOR A MINIMUM OF ONE (1) YEAR FROM THE DATE OF THE CERTIFICATE OF OCCUPANCY OF THE PROJECT. 7. THE CONTRACTOR IS TO REVIEW THE PLANS AND FIELD CONDITIONS AND BECOME FAMILIAR WITH THE WORK. SHOULD HE BECOME AWARE OF ANY DISCREPANCIES HE SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING FOR CLARIFICATION. 8. ALL BIDDERS AND THEIR SUBS SHALL BE LICENSED IN THE STATE OF FLORIDA WITH NECESSARY WORKMAN'S COMP.: INSURANCE AND ABILITY FOR BONDING. 9. THE OWNER HAS THE RIGHT TO REJECT ANY AND ALL BIDS. 10. THE ENGINEER SHALL APPROVE SUBSTITUTIONS OF ITEMS BY THE CONTRACTOR OR HIS SUBS WHICH THEY BELIEVE _ TO BE EQUAL OR BETTER: SAID ITEMS WHEN REQUIRING APPROVAL BY A BUILDING OFFICIAL ARE TO BE SUBMITTED TO THE BUILDING DEPARTMENT. 11. THE GENERAL CONTRACTOR IS TO MAINTAIN REQUIRED BARRICADES, WARNING DEVICES, SHORING AND ALL MEASURES NECESSARY TO PROTECT THE WORKMEN AND THE PUBLIC AS REQUIRED BY THE REGULATORY BODIES HAVING JURISDICTION. 12. THE GENERAL CONTRACTOR IS TO COORDINATE THE WORK OF ALL TRADES. THE ARCHITECT WILL NOT BE PROVIDING CONSTRUCTION SERVICES: THE OWNER AND THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE QUALITY OF THE WORKMANSHIP. 13. THE SHEETS OF THE CONSTRUCTION DOCUMENTS ARE COMPLMENTARY TO EACH OTHER. WHAT IS CALLED FOR ON ONE IS BINDING FOR ALL. 14. THE GENERAL CONTRACTOR SHALL OBTAIN ADEQUATE LIABLITY INSURANCE AND MAINTAIN THE POLICY THROUGHOUT THE PROJECT. 15. COORDINATION OF ALL THE WORK SHALL BE THE GENERAL CONTRACTORS RESPONSIBILITY AND ALL SUBCONTRACTORS SHALL REVIEW ANY PLANS THAT MAY AFFECT THE INSTALLATION OF THEIR WORK. 16. THE GENERAL CONTRACTOR OR HIS SUBS SHALL ASK FOR DETAILS WHENEVER UNCERTAIN ABOUT THE METHODS OF INSTALLATIONS. LACK OF DETAILS 140T REQUESTED SHALL NOT EXCUSE IMPROPER INSTALLATION. 17. CONTRACTOR NOTE - BIDDERS, BEFORE SUBMITTING BIDS, SHALL VISIT AND CAREULLY EXAMINE THE AREA AFFECTED BY THE WORK TO FAMILIARIZE THEMSELVES WITH THE SITE CONDITIONS AND THE DIFFICULTIES THAT WILL AFFECT THE EXECUTION OF THE WORK. SUBMISSION OF THE PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE AND MAY LATER BE REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HAD SUCH AN EXAMINATION BEEN MADE. 18. CONTRACTOR IS TO COORDINATE HIS WORK WITH THAT OF THE MECHANICAL. ELECTRICAL, PLUMBING, STRUCTURAL AND SITE ENGINEERS DOCUMENTS BEFORE STARTING WORK. 19. ALL WORK IS TO CONFORM TO THE LATEST EDITION OF LOCAL CODES. 20. ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED PRIOR TO STARTING CONSTRUCTION. UNDER NO CIRCUMSTANCES IS THE CONTRACTOR TO SCALE DRAWINGS TO OBTAIN DIMENSIONS. IF THERE IS ANY QUESTION REGARDING A LACK OF DIMENSIONS, THE CONTRACTOR IS TO NOTIFY THE ARCHITECT AND INFORMATION WILL BE PROVIDED. 21. CONTRACTOR SHALL PROVIDE ALL NECESSARY SHORING AND BARRICADES ETC., TO ACCOMPLISH ALL WORK IN AN APPROVED MANNER. 22. CONSTRUCTION SHALL MEET OR EXCEED REQUIREMENTS'OF ALL APPLICABLE AND APPROPRIATE BUILDING CODES, STANDARDS AND ORDINANCES. 23. IT IS THE INTENT OF THE :ENGINEER THAT THIS WORK BE IN CONFORMANCE WITH THE BUILDING AUTHORITY HAVING JURISDICTION OVER THIS WORK AND OCCUPANCY. ALL CONTRACTORS SHALL DO THE WORK IN COMPLIANCE WITH THE FLORIDA BUILDING CODE, NATIONAL ELECTRIC CODE, N.r.P.A. OSHA, AND OTHER APPLICABLE CODES AND REGULATIONS. ALL WORK SHALL BE DONE UNDER PROPER BUILDING PERMITS. 24. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AT THE JOB SITE AND REPORT ANY DISCREPANCIES WITH THE PLANS TO THE ENGINEER PRIOR TO DOING '`THE WORK. 25. THESE PLANS ARE THE PROPERTY OF THE ENGINEER AND SHALL NOT BE USED, REPRODUCED, OR CHANGED IN ANY MANNER WITHOUT THE PRIOR EXPRESSED WRITTEN CONSENT OF THE'ENGINEER. ANY CHANGES, DELETIONS OR ADDITIONS TO THESE PLANS WITHOUT THE ENGINEER'S CONSENT, 15 A VIOLATIONS OF APPLICABLE STATE LAWS. 26. THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, A .A. I)OCUMEI$T A201 OF THE AMERICAN INSITITUTE OF ARCHITECTS, 1987 EDITIONS SHALL BE MADE PART DIT AND APPLY TO THE WORK EXECUTED BY THESE PLANS. _ 27. IT IS NOT THE,INTENT,C THES Tfl �W F VRY MINOR flE,TA1L OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED 10°FtJRN#SH° - 'M4 T XEMIL ITEMS REQUIRED TO--COMPLETE T+iE WORK WITH GOOD WORKMANSHIP AND ASSURE PROPER WORKING ORDER. 28. NO DEVIATIONS SHALL BE MADE FROM THESE DRAWINGS WITHOUT THE ENGINEER'S PRIOR WRITTEN APPROVAL. 29. ALL WORK AND MATERIAL SHALL BE FREE FROM DEFECTS, DAMAGE AND SHALL BE -NEW AND FULLY OPERATIONAL UPON FINAL ACCEPTANCE BY OWNER. 30. THE CONTRACTOR SHALL COORDINATE AND SUPERVISE HIS WORK AND WORK BY SUBCONTRACTORS. 31. THE CONTRACTOR SHALL COORDINATE ALL PARKING, STORAGE, TRASH REMOVAL, ETC. 32. THE CONTRACTOR SHALL SUPPLY AND PAY FOR ALL REQUIRED PERMITS, INSURANCE, LICENSES, TAXES, ETC. REQUIRED TO DO THIS WORK. INDEX CS -1 COVER SHEET M -1 HVAC FLOOR PLAN M -2 HVAC DETAILS AND SCHEDULES PLAN REVIEW DATA APPLICABLE CODES: 2010 FLORIDA BUILDING CODE (FBC) 2010 FLORIDA EXISTING BUILDING CODE (FEBC) NEC 2008 DESCRIPTION OF WORK: MECHANICAL WORK: EXISTING RTU TO REMAIN AS IS. DUCT LAYOUT EXITING TO REMAIN ADJUST ACCORDING TO GRILL LAYOUT NEW EXHAUST FAN AND NEW EXHAUST GAL. EXHAUST DUCT AS PER PLAN PEDICURE SALON 1403 W. BOYNTON BEACH BLVD BOYNTON BEACH FL CONSTRUCTION AREA W Z 6 & 1 v logo lfqm6mT6 ffp vivo tip I 'l la I v a, code tabulation o THIS PROJECT IS TO BE BUILT IN ACCORDANCE WITH THE FBC 2010, LIFE SAFETRY 101 AND NEC 2008 ED O OCCUPANCY USE: PEDICURE SALON O OCCUPANCY GROUP: GROUP B O TYPE OF CONSTRUCTION: TYPE IIB (SPRINKLERED) SPA AREA = 788 SF FE REQUIRED = 788/2500 =1 REQUIRED (1 FE PROVIDED) THE,,-PLAN SHALL COMPLY W/- ALL REQUIREMENTS OF THE FLOR, RIDA FR PREVE O'N CODE 2010 EDITION. THE BROWAR - AMENDMENTS TO THE FLORIDA FIRE PE 2012, NFPA 101 (LIFE SAFETY CODE) 0 09� AND NFPA 1 (UNIFORM FIRE CO 009_E_DITION. THE TENANT SPACE SHALL COMPLY W/- MODIFICATION AS PER LIFE SAFETY 101 CH 43 - FIRESAFE ANY OPENINGS IN FIRE CONSTRUCTION TO MATCH ASSEMBLY PENETRATED AND MIN 1 HR F &T RATING PER NFPA 101:8.3.5.1.3 AND / OR 8.3.5.1.4 AS APPLICABLE THE LEVEL OF ALTERATIONS PURSUANT TO SECTIONS 602, 603, 605 & 610 SHALL COMPLY W/- LEVEL 1 OF THE FBC 2010 EXISTING BUILDING FBC CHANGE OF USE CLASSIFICATIONS: EXI5TIN6 SPACE WA5 CLASSIFIED AS 5U51NE55 (HAIR 5ALON) PROP05ED USE : BZINE55 (BEAUTY SALON) TENANT SPACE COMPLIES W/- EXISTING BUILDING 2010 SECTION 4 102, 4 104, 0106, 0110 d 4112 OF THE FBC 2010 EXI5TIN6 BUILDING FBC IF THE ADDRE -5 15 PLACE ON THE STOREFRONT THE NUMBERS SHALL BE WHITE. WHEN PLACED ON A LIGHT COLORED BACKGROUND THE COLOR SHALL BE BLACK. ALL 516N5 AND LETTERING SHALL BE APPROVED BY LANDLORD. EX IHR FIRE RATED WALL FROM FLR TO CEILING m n 0 cD U H 0 Q w _p ^ Q ^ � `� I t . � L v) U) H EX MASONRY WALL A/- STUCCO FIN ON EXTERIOR AND DRYWALL FURRING EX MASONRY WALL TO REMAIN PERMITTED EX INTERIOR STUD WALL TO REMAIN PERMITTED EX NON BEARING 1 HR RATED WALL PERMITTED NEW INTERIOR STUD WALL TO BE PERMITTED f EX IHR FIRE RATED WALL FROM FLR TO CEILING SEX HR FIRE RATED EX IHR FIRE RATED WALL FROM FLR TO WALL FROM FLR TO IC, CEILING battery back up m ® CEILING a BACK -UP AND 5PACE 20' -0" APA AND 01' -0" H16H MAX (TYP) O V* LIANCE SECTION V U G n .9 U) t Q � n vJ J \ Z EX 1/2" TAPERED DOWN PART ELEV OF ARCH NICHE lo'-o CEILIN6 FIELD VERIFY PROVIDE 2 "xs AD 111-OUGIN6 ® GRAB RAIL5 TO AITH5TAN12 250# MIN 3 5/6 229a mtl track @ 4' -0" off 5 SAY 256A MTL. TRACK FASTEN TO FLR A/- 3/4" — POWER ACTUATED PIN5 @ 24" OX. ACOUSTIC CEILING 5 5/8" 256A MTL. STUD5 ® 16" O.C. VV I LAYER OF 1/2" GYP. BOARD ON EACH 51DE SCREWED TO STUDS YJ/- DRYWALL SCREWS ® 12" 0 /6. SHEDULED BASE arwpmn r-n P new Mid 1 TYP STUD WALL Q -, ) xrs SYSTEM No W L 1084 F- Rating - I Hour T- Rating -'0 Hour 0 PRE -RATED CONCRETE FLOORS OR BLOCKS WALL5 - MIN. 1 -1/2" THICKNESS. PLASTIC, PIPE 6`0, (OR SMALLER) %H. 40 PVC PIPE FOR USE IN CLOSED OR OPEN PIPING SYSTEMS. A MAX. ANNULAR SPACE OF 5/8" 15 REQUIRED. C TREM STOP A5 - IN5TUME5GENT ARAP STRIPS, GONTINUO5LY WRAPPED AROUND OUTER CIRCUNFERENCE OF THE PIPE IN TAO OF. iYELVE ARAP5. ( 11`-' STOP W,R - PREFABRICATED 5TEEL COLLAR YRAPPED OVER THE WRAP 5TRIP5 ( ITEM 3) AND MECHANICALLY FASTENED TO THE FLOOR OR WALL ASSEMBLY. G ) TREM STOP ABM OR FYRE -51L - MIN. 1/4" BEAD OF SEALANT APPLIED AT THE INTERFACE OF THE CONCRETE SLAB AND STEEL COLLAR, AND AT THE INTERFACE OF THE STEEL COLLAR AND PIPE. 6 MORTAR - MIN. 4-1/2" THICKNE55 OF MORTAR OR HYDRAULIC CEMENT APPLIED AITHIN ANNULUS, FLUSH WITH BOTH SURFACES FLOOR OR WALL A55EMBLY. NOTE : IN FLOORS, APPLY BELOA THE CONCRETE SLAB. IN WALLS, APPLY TO EACH 51DE OF ASSEMBLY. ROO FINISH SCHEDULE R O J N - (tS o O O 1iC o� L___, L - c Z (U rr 0 i LL �j r °y ! I° y�7 • �ti B ! y9 � LF �� 0�= o w IV § Ez4,Gxe u SF a 0 0 W W 0 (fJ a z z 2 w 0 a w EX IHR FIRE RATED WALL FROM FLR TO EX IHR FIRE RA' ED WALL FROM FLR TO IC, - A battery back up CEILING ® CEILING W/ - ADA BACK -UP AND 5PACE 20' -0" APA AND 01' -0" H16H MAX (TYP) t V* LIANCE SECTION IN Reception / Waitng .9 z o OCCUPANCY LOAD ACT 1 PLAT SHALL BE 4 s I D 0 POSTED AT ENTRANCE V 0 w 0 EX 1/2" TAPERED ® STEP DOWN o Qi ADDRESS AND PLACE �EX 36 "x80" ALUM FRAMED z ON DOOR IN 6" HIGH 6LA55 DOOR LETTERS ACC DEMO FLOOR PLAN showing existing conditions PROPOSED FLOOR PLAN EX REFLECTED CEILING PLAN SCALE: 1/4 " =1' -0" SCALE: 1/4 " =1' -0' A NO F SCALE: 1/4' =1'-O° o 0 PRIOR USED: (GROUP B) PROPOSED USED: BEAUTY SALON {GROUP B} U w 0 PRE -RATED CONCRETE FLOORS OR BLOCKS WALL5 - MIN. 1 -1/2" THICKNESS. PLASTIC, PIPE 6`0, (OR SMALLER) %H. 40 PVC PIPE FOR USE IN CLOSED OR OPEN PIPING SYSTEMS. A MAX. ANNULAR SPACE OF 5/8" 15 REQUIRED. C TREM STOP A5 - IN5TUME5GENT ARAP STRIPS, GONTINUO5LY WRAPPED AROUND OUTER CIRCUNFERENCE OF THE PIPE IN TAO OF. iYELVE ARAP5. ( 11`-' STOP W,R - PREFABRICATED 5TEEL COLLAR YRAPPED OVER THE WRAP 5TRIP5 ( ITEM 3) AND MECHANICALLY FASTENED TO THE FLOOR OR WALL ASSEMBLY. G ) TREM STOP ABM OR FYRE -51L - MIN. 1/4" BEAD OF SEALANT APPLIED AT THE INTERFACE OF THE CONCRETE SLAB AND STEEL COLLAR, AND AT THE INTERFACE OF THE STEEL COLLAR AND PIPE. 6 MORTAR - MIN. 4-1/2" THICKNE55 OF MORTAR OR HYDRAULIC CEMENT APPLIED AITHIN ANNULUS, FLUSH WITH BOTH SURFACES FLOOR OR WALL A55EMBLY. NOTE : IN FLOORS, APPLY BELOA THE CONCRETE SLAB. IN WALLS, APPLY TO EACH 51DE OF ASSEMBLY. ROO FINISH SCHEDULE R O J N - (tS o O O 1iC o� L___, L - c Z (U rr 0 i LL �j r °y ! I° y�7 • �ti B ! y9 � LF �� 0�= o w IV § Ez4,Gxe u SF a 0 0 W W 0 (fJ a z z 2 w 0 a w back -up exit sign vw/- battery back up EMERGENCY LITE WV- BATTERY BACK -UP AND 5PACE 20' -0" APA AND 01' -0" H16H MAX (TYP) t 2A2050 FIRE EXTIN6HUI5HER IA:/ A !IA V ^1= 0 %^1" LATH � Aa" 0 PRE -RATED CONCRETE FLOORS OR BLOCKS WALL5 - MIN. 1 -1/2" THICKNESS. PLASTIC, PIPE 6`0, (OR SMALLER) %H. 40 PVC PIPE FOR USE IN CLOSED OR OPEN PIPING SYSTEMS. A MAX. ANNULAR SPACE OF 5/8" 15 REQUIRED. C TREM STOP A5 - IN5TUME5GENT ARAP STRIPS, GONTINUO5LY WRAPPED AROUND OUTER CIRCUNFERENCE OF THE PIPE IN TAO OF. iYELVE ARAP5. ( 11`-' STOP W,R - PREFABRICATED 5TEEL COLLAR YRAPPED OVER THE WRAP 5TRIP5 ( ITEM 3) AND MECHANICALLY FASTENED TO THE FLOOR OR WALL ASSEMBLY. G ) TREM STOP ABM OR FYRE -51L - MIN. 1/4" BEAD OF SEALANT APPLIED AT THE INTERFACE OF THE CONCRETE SLAB AND STEEL COLLAR, AND AT THE INTERFACE OF THE STEEL COLLAR AND PIPE. 6 MORTAR - MIN. 4-1/2" THICKNE55 OF MORTAR OR HYDRAULIC CEMENT APPLIED AITHIN ANNULUS, FLUSH WITH BOTH SURFACES FLOOR OR WALL A55EMBLY. NOTE : IN FLOORS, APPLY BELOA THE CONCRETE SLAB. IN WALLS, APPLY TO EACH 51DE OF ASSEMBLY. ROO FINISH SCHEDULE R O J N - (tS o O O 1iC o� L___, L - c Z (U rr 0 i LL �j r °y ! I° y�7 • �ti B ! y9 � LF �� 0�= o w IV § Ez4,Gxe u SF a 0 0 W W 0 (fJ a z z 2 w 0 a w a 0 x .9 z o v 0 I D 0 V 0 w 0 o z 0) J CL 0 o 0 N U w m 0 (D n Z m ■ a fn w ^, 'ArW 0 W LL z a 2 I.i. O �. Q T� LL LL d [ w F i / ` V w K < LL z o a� i m m 0 0 � � O � (n V 0 d z pct o 0 . CY) C o m � © ^ 0 W 0 0 0 m 0 o c� r drawn by: mf Uj W checked by: J. Biagi z date: 07 -16 -14 5 a job no: w W sheet: x � 0 LL Cn z 0 0 0 X 0 0 0 Cr w 6i z R O J N - (tS o O O 1iC o� L___, L - c Z (U rr 0 i LL �j r °y ! I° y�7 • �ti B ! y9 � LF �� 0�= o w IV § Ez4,Gxe u SF a 0 0 W W 0 (fJ a z z 2 w 0 a w a 0 x .9 z o v 0 I D 0 V 0 w 0 o z 0) J CL 0 o 0 N U w m 0 (D n Z m ■ a fn w ^, 'ArW 0 W LL z a 2 I.i. O �. Q T� LL LL d [ w F i / ` V w K < LL z o a� i m m 0 0 � � O � (n V 0 d z pct o 0 . CY) C o m � © ^ 0 W 0 0 0 m 0 o c� r drawn by: mf Uj W checked by: J. Biagi z date: 07 -16 -14 5 a job no: w W sheet: x � 0 LL Cn z 0 0 0 X 0 0 0 Cr w 6i z code tabulation o THIS PROJECT IS TO BE BUILT IN ACCORDANCE WITH THE FBC 2010, LIFE SAFETRY 101 AND NEC 2008 ED • OCCUPANCY USE: PEDICURE SALON • OCCUPANCY GROUP: GROUP B • TYPE OF CONSTRUCTION: TYPE IIB ( UNSPRINKLERED) SPA AREA 788 SF FE REQUIR - 788/2500 =1 REQUIRED VIDED) WALL LEGEND O O 17 77 77 77777 THE TENANT SPACE SHALL COMPLY W/- MODIFICATION AS PER LIFE SAFETY 101 CH 43 SAFE ANY OPENINGS IN FIRE CONSTRUCTION TO MATCH ASSEMBLY PENETRATED AND MIN F 8 ING PER A 101:8 . 1.3 AND / 8.3.5.1.4 AS APPLICABLE IF THE ADDRE55 15 PLACE ON THE STOREFRONT OCCUPANCY TAB THE NUMBERS SHALL BE WHITE. AHEN PLACED ON TENANT SPACE (788 /100) = IF A LIGHT COLORED BACKGROUND THE COLOR SHALL BE BLACK. TOTAL OCCUPANCY = 7P ALL SIGNS AND LETTERING SHALL BE APPROVED EX MASONRY AALL A/- BY LANDLORD. 5TU000 FIN ON EXTERIOR AND DRYWALL FURRING EX IHR f HALL F6 CEILING EX IHR WALL I CEILIN :X IHR FIRE RATED O LL FROM FLR TO :EILIN6 IHR FIRE RATED L FROM FLR TO LING 3 PP X IHR FIRE RATED ALL FROM FLR TO EILING DEMO FLOOR PLAN showing existing conditions SCALE: 1/4 =1 ' -0" PRIOR USED: (GROUP B) EX MASONRY WALL TO REMAIN PERMITTED EX INTERIOR STUD WALL TO REMAIN PERMITTED EX NON BEARING 1 HR RATED WALL PERMITTED NEW INTERIOR STUD WALL TO BE PERMITTED C �1 in 0 d- 4 r 0 N n N N ADDRE55 AND PLACE ON DOOR IN 6" HIGH LETTERS EX 1/2" TAPERED STEP_, DOWN EX (2)24"40" INSUL MTL DOOR TO REMAIN 5 Alm EX 36"40" ALUM FRAMED IN DOOR IN b" H1614 �' GLASS DOOR ETTERS PROPOSED FLOOR PLAN SCALE: 1/4 " =1 PROPOSED USED: BEAUTY SALON (GROUP B) OIL 10'-0' CEILING FIELD VERIFY PROVIDE 2 "xs AD BLOCKING ® 610B RAILS TO AITHSTAO 250# MIN 3 518 229a mtl trek ® 4'-0" Off 3 5/6" 2%A MTL. TRACK FASTEN TO FLR W/- 3/4" — FOYER ACTUATED PINS 24 0 /C. ACOUSTIC CEILING 3 5/8" 256A MTL. STUDS ® 16" O.C. At I LAYER OF 1/2" GYP. BOARD ON EACH SIDE 50REAED TO STUDS W/- DRYWALL 5CREA5 ® 12" 0 1C. CHEDUL.ED BASE 5CHEDULED FLOOR FIN 1 TYP STUD WALL 1 xTs EX REFLECTED CEILING PLAN SCALE: I /4 "=I' -0" SECTION A -A HALL ASSEMBLY - THE FIRE RATED GYPSUM WALLBOARD /57W HALL A55EMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U -300 OR 0-400 SERIES HALL AND PARTITION DE5I6NS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOAING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL. CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC. STEEL 5TUD5 TO BE MIN. 3-5/8 IN. WIDE AND SPACED MAX. 24 IN. OC. B. AALLBOARD , GYPSUM* - NOM 5/8 IN. THICK GYPSUM AALLBOARD, AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. DIAM OF OPENING 15 1 -1/2 IN. LARGER THAN THE OUTSIDE DIAM OF PIPE. THROUGH - PENETRANT - ONE METALLIC, PIPE, CONDUIT OR TUBING TO BE CENTERED WITHIN THE FIRESTOP SYSTEM . AN ANNULAR SPACE OF 3/4 IN. 15 REQUIRED WITHIN THE FIRE5TOP SYSTEM . PIPE CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPE5 AND 51ZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED : A. STEEL PIPE - NOM 12 IN. DIAM ( OR SMALLER ) SCHEDULE 10 ( OR HEAVIER ) STEEL PIPE. B. CONDUIT - NOM 6 IN. DIAM (OR SMALLER) ELECTRICAL METALLIC TUBING OR STEEL CONDUIT. C. COPPER TUBING - NOM 6 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. D. COPPER PIPE - NOM 6 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. FILL, VOID OR CAVITY MATERIALS* - SEALANT - MIN. 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED AITHIN ANNULUS, FLUSH WITH BOTH 5URFACE5 OF WALL A55EMBLY. MINNESOTA MINING AND MFG. CO. - FB -2000+ *BEARING THE UL CLA551FICATION MARKING. TREMstop WS and TREMstop MCR. CAJ 2068 F- Rating = 2Hmr T -QmHmm a lWmr b 2 O PRE -RA7W CONCRETE FLOORS OR BLOCKS HALLS - MIN. 1 -1/2" THICKNESS. ,✓ PLASTIC PIPE 6" 4 , (OR SMALLER) 50H. 40 PVC PIPE FOR USE IN CLOSED OR OPEN PIPING SYSTEMS. A MAX. ANNULAR ,✓ SPACE OF 5/8" 15 REQUIRED. TREM STOP AS - IN5TUME50ENT ARAP STRIPS, CONTINUOSLY ARAPPED AROUND OUTER CIRCUNFERENCE OF THE PIPE IN TWO /� STACKS OF TWELVE ARAP5. 4 ) TREM STOP MOR - PREFABRICATED 57BEL LOLL AR WRAPPED OVER THE ARAP STRIPS ( ITEM 3) AND MECHANICALLY �� FASTENED TO THE FLOOR OR HALL ASSEMBLY. O TREM STOP ABM OR FYRE -SIL - MIN. 1/4" BEAD OF SEALANT APPLIED AT THE INTERFACE OF THE CONCRETE SLAB AND STEEL. COLLAR, AND AT THE INTERFACE OF THE STEEL COLLAR AND PIPE. O MORTAR - MIN. 4-1/2" THICKNESS OF MORTAR OR HYDRAULIC CEMENT APPLIED AITHIN ANNULUS, FLUSH AITH BOTH SURFACES OF FLOOR OR WALL ASSEMBLY. NOTE : IN FLOORS, APPLY BELOA THE CONCRETE SLAB. IN WALL5, APPLY TO EACH SIDE OF ASSEMBLY. ROOM FINISH SCHEDULE TYPE OF AS LY: = PEDICURE SALON (GROUP B) exit sign W- battery back up CONSTRUCTION TYPE: = TYPE IIB UNSPRINKLERED cEl FLAME SPREAD: = 26 -75 NM FIN15H CLASS: = CLA55 'C' FIN15HE5 � 1� FE REQUIRED = 788/2500 =1 REQUIRED � (I FE PROVIDED) m SMOKE DEVELOPMENT = 0-450 IF THE ADDRE55 15 PLACE ON THE STOREFRONT OCCUPANCY TAB THE NUMBERS SHALL BE WHITE. AHEN PLACED ON TENANT SPACE (788 /100) = IF A LIGHT COLORED BACKGROUND THE COLOR SHALL BE BLACK. TOTAL OCCUPANCY = 7P ALL SIGNS AND LETTERING SHALL BE APPROVED EX MASONRY AALL A/- BY LANDLORD. 5TU000 FIN ON EXTERIOR AND DRYWALL FURRING EX IHR f HALL F6 CEILING EX IHR WALL I CEILIN :X IHR FIRE RATED O LL FROM FLR TO :EILIN6 IHR FIRE RATED L FROM FLR TO LING 3 PP X IHR FIRE RATED ALL FROM FLR TO EILING DEMO FLOOR PLAN showing existing conditions SCALE: 1/4 =1 ' -0" PRIOR USED: (GROUP B) EX MASONRY WALL TO REMAIN PERMITTED EX INTERIOR STUD WALL TO REMAIN PERMITTED EX NON BEARING 1 HR RATED WALL PERMITTED NEW INTERIOR STUD WALL TO BE PERMITTED C �1 in 0 d- 4 r 0 N n N N ADDRE55 AND PLACE ON DOOR IN 6" HIGH LETTERS EX 1/2" TAPERED STEP_, DOWN EX (2)24"40" INSUL MTL DOOR TO REMAIN 5 Alm EX 36"40" ALUM FRAMED IN DOOR IN b" H1614 �' GLASS DOOR ETTERS PROPOSED FLOOR PLAN SCALE: 1/4 " =1 PROPOSED USED: BEAUTY SALON (GROUP B) OIL 10'-0' CEILING FIELD VERIFY PROVIDE 2 "xs AD BLOCKING ® 610B RAILS TO AITHSTAO 250# MIN 3 518 229a mtl trek ® 4'-0" Off 3 5/6" 2%A MTL. TRACK FASTEN TO FLR W/- 3/4" — FOYER ACTUATED PINS 24 0 /C. ACOUSTIC CEILING 3 5/8" 256A MTL. STUDS ® 16" O.C. At I LAYER OF 1/2" GYP. BOARD ON EACH SIDE 50REAED TO STUDS W/- DRYWALL 5CREA5 ® 12" 0 1C. CHEDUL.ED BASE 5CHEDULED FLOOR FIN 1 TYP STUD WALL 1 xTs EX REFLECTED CEILING PLAN SCALE: I /4 "=I' -0" SECTION A -A HALL ASSEMBLY - THE FIRE RATED GYPSUM WALLBOARD /57W HALL A55EMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U -300 OR 0-400 SERIES HALL AND PARTITION DE5I6NS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOAING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL. CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC. STEEL 5TUD5 TO BE MIN. 3-5/8 IN. WIDE AND SPACED MAX. 24 IN. OC. B. AALLBOARD , GYPSUM* - NOM 5/8 IN. THICK GYPSUM AALLBOARD, AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. DIAM OF OPENING 15 1 -1/2 IN. LARGER THAN THE OUTSIDE DIAM OF PIPE. THROUGH - PENETRANT - ONE METALLIC, PIPE, CONDUIT OR TUBING TO BE CENTERED WITHIN THE FIRESTOP SYSTEM . AN ANNULAR SPACE OF 3/4 IN. 15 REQUIRED WITHIN THE FIRE5TOP SYSTEM . PIPE CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPE5 AND 51ZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED : A. STEEL PIPE - NOM 12 IN. DIAM ( OR SMALLER ) SCHEDULE 10 ( OR HEAVIER ) STEEL PIPE. B. CONDUIT - NOM 6 IN. DIAM (OR SMALLER) ELECTRICAL METALLIC TUBING OR STEEL CONDUIT. C. COPPER TUBING - NOM 6 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. D. COPPER PIPE - NOM 6 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. FILL, VOID OR CAVITY MATERIALS* - SEALANT - MIN. 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED AITHIN ANNULUS, FLUSH WITH BOTH 5URFACE5 OF WALL A55EMBLY. MINNESOTA MINING AND MFG. CO. - FB -2000+ *BEARING THE UL CLA551FICATION MARKING. TREMstop WS and TREMstop MCR. CAJ 2068 F- Rating = 2Hmr T -QmHmm a lWmr b 2 O PRE -RA7W CONCRETE FLOORS OR BLOCKS HALLS - MIN. 1 -1/2" THICKNESS. ,✓ PLASTIC PIPE 6" 4 , (OR SMALLER) 50H. 40 PVC PIPE FOR USE IN CLOSED OR OPEN PIPING SYSTEMS. A MAX. ANNULAR ,✓ SPACE OF 5/8" 15 REQUIRED. TREM STOP AS - IN5TUME50ENT ARAP STRIPS, CONTINUOSLY ARAPPED AROUND OUTER CIRCUNFERENCE OF THE PIPE IN TWO /� STACKS OF TWELVE ARAP5. 4 ) TREM STOP MOR - PREFABRICATED 57BEL LOLL AR WRAPPED OVER THE ARAP STRIPS ( ITEM 3) AND MECHANICALLY �� FASTENED TO THE FLOOR OR HALL ASSEMBLY. O TREM STOP ABM OR FYRE -SIL - MIN. 1/4" BEAD OF SEALANT APPLIED AT THE INTERFACE OF THE CONCRETE SLAB AND STEEL. COLLAR, AND AT THE INTERFACE OF THE STEEL COLLAR AND PIPE. O MORTAR - MIN. 4-1/2" THICKNESS OF MORTAR OR HYDRAULIC CEMENT APPLIED AITHIN ANNULUS, FLUSH AITH BOTH SURFACES OF FLOOR OR WALL ASSEMBLY. NOTE : IN FLOORS, APPLY BELOA THE CONCRETE SLAB. IN WALL5, APPLY TO EACH SIDE OF ASSEMBLY. ROOM FINISH SCHEDULE exit = and emergency lite combo w/- battery back -up ® exit sign W- battery back up RNA cEl BACK -UP AND SPACE 20' -0" APART AND 4' -0" HIGH MAX (TYP) ROOM NAME NM BASE WALLS � 1� AFF TO HANDLE REMARKS � O m 0 N U z 'a CID a +� X E 2 Z C W m c a� p ll�l L . Ica U) 0 C LU QII z J Z >% a (ll 00 N z ° C CV N O J 0 0 CIO O C >>O% fit c.� drawn by: U mf checked by: J. Biagi F 07 -16 -14 ° w ° w a# p tL v v u w RECEFnoN / MAmN6 AREA • • • • • PEDICURE • • • • • PEDICURE • • • • • OFFICE • • • • • unu1Y ROOM • • • • • EX TOILET • • • • • • ACOUSTIC CEILING SCHEDULE NO TION ACT -1 REPLACE STANDARD 2'X 4' TEGULAR TILE 10' -0" AFF rev. descrioti ky I elate exit = and emergency lite combo w/- battery back -up ® exit sign W- battery back up EMER6ENCY LITE A/- BATTERY BACK -UP AND SPACE 20' -0" APART AND 4' -0" HIGH MAX (TYP) (� 2A2050 FIRE EXTINGHUISHER �J A/ -A MAX OF 20lbs. MTD ® 48" � 1� AFF TO HANDLE ACOUSTIC CEILING SCHEDULE NO TION ACT -1 REPLACE STANDARD 2'X 4' TEGULAR TILE 10' -0" AFF rev. descrioti ky I elate ! , ® 31 , tSk9llYt 4`�,® d- � 1� L IL � O m 0 N U �1L 'a CID +� X E 2 z� C MM W m c a� ! , ® 31 , tSk9llYt 4`�,® sheet: ■J s SYSTEM No W -L 1084 F- Rating - I Hour' T- Ratina - 0 Hr PART ELEV OF ARCH NICHE no , of � m N U 'a CID E C MM W a� p C L . Ica U) 0 C V z >% CIO (ll 00 N z ° C CV N O •V 0 0 CIO O C >>O% c.� drawn by: mf checked by: J. Biagi date: 07 -16 -14 job no: sheet: ■J s SYSTEM No W -L 1084 F- Rating - I Hour' T- Ratina - 0 Hr PART ELEV OF ARCH NICHE no , of code tabulation O THIS PROJECT IS TO BE BUILT IN ACCORDANCE WITH THE FBC 2010, LIFE SAFETRY 101 AND NEC 2008 ED • OCCUPANCY USE: PEDICURE SALON • OCCUPANCY GROUP: GROUP B • TYPE OF CONSTRUCTION: (TYPE 1113 (UNSPRINKLERED) SPA AREA = 788 SF FE REQUIRED = 788/2500 =1 REQUIRED (1 FE PROVIDED) THE PLAN SHALL COMPLY W/- ALL REQUIREMENTS OF THE FLORIDA FIRE PREVENTION CODE 2010 EDITION. THE BROWARD COUNTY AMENDMENTS TO THE FLORIDA FIRE PREVENTION CODE 2012, NFPA 101 (LIFE SAFETY CODE) 2009 EDITION AND NFPA 1 (UNIFORM FIRE CODE) 2009 EDITION. THE TENANT SPACE SHALL COMPLY W/- MODIFICATION AS PER LIFE SAFETY 101 CH 43 FIRESAFE ANY OPENINGS IN FIRE CONSTRUCTION TO MATCH ASSEMBLY PENETRATED AND MIN 1HR F &T RATING PER NFPA 101:8.3.5.1.3 AND / OR 8.3.5.1.4 AS APPLICABLE WALL LEGEND IF THE ADDRE55 15 PLACE ON THE STOREFRONT OCCUPANCY TAB THE NUMBERS SHALL BE WHITE. INHEN PLACED ON TENANT SPACE ("188 /100) = IF A LIGHT COLORED BACKGROUND THE COLOR SHALL BE BLACK. TOTAL OCCUPANCY : TP ALL 51615 AND LETTERING SHALL BE APPROVED EX MASONRY WALL W/- BY LANDLORD. STUCCO FIN ON EXTERIOR AND DRYWALL FURRING EX IHR f WALL FF CEILING EX IHF WALL GEILIN EX IHR FIRE RATED WALL FROM FLR TO CEILING ( IHR FIRE RATED 4LL FROM FLR TO TILING n L D J n EX IHR FIRE RATED WALL FROM FLR TO CEILING DEMO FLOOR PLAN showing existing conditions 50ALE: 1 /4"- I' -0" PRIOR USED: (GROUP B) EX MASONRY WALL TO REMAIN PERMITTED EX INTERIOR STUD WALL TO REMAIN PERMITTED EX NON BEARING 1 HR RATED WALL PERMITTED NEW INTERIOR STUD WALL TO BE PERMITTED no pentration of fire wall in ADDRESS AND PLACE ON DOOR IN 6" HIGH LETTERS EX 1/2" TAPERED STEE DOWN AV EX (2)24'x80" INSUL MTL DOOR TO REMAIN 4 0 T r N N 9 n DURESS OM AND PLACE VEX 6 x80" ALUM FRAMED N DOOR IN 6' HIGH GLA DOOR ertERS PROPOSED FLOOR PLAN SCALE: 1/4' =1' -0" PROPOSED USED: BEAUTY SALON (GROUP B) 10' -O' GEILIN6 PIEI.D vERI PROVIDE 2 "xs YO BLOGKIN& 6RA5 RAILS TO WITHSTAND 250# MIN 3 5/8 229a mtl track ® 4' -0' off 3 5/8" 256A MTL. TRACK FASTEN TO FLR W/- 3/4" — POWER ACTUATED PINS 24" 0 /G. ACOUSTIC CEILING 3 5/8" 256A MTL. STUDS ® I6" O.G. W/ I LAYER OF I /2" GYP. BOARD ON EACH 5IDE 50REY ED TO STUDS NU- DRYWALL SCREWS ® 12" 0 10. CHEDULED BASE SCHEDULED FLOOR FIN (I�TYP STUD WALL Q "`5 SCALE: 1 /4" -1' -O" 1� LL LL F- z rev. clescription 6 I date SECTION A -A WALL A55EMBLY - THE FIRE RATED GYPSUM WALLBOARD /STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U -300 OR U-400 SERIES WALL AND PARTITION DE516% IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CON515T OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OG. STEEL STUDS TO BE MIN. 3 -5/8 IN. WIDE AND SPACED MAX. 24 IN. OG. B. WALLBOARD, GYPSUM* - NOM 5/8 IN. THICK GYPSUM YrALLBOARD, AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. DIAM OF OPENING 15 1 -1/2 IN. LARGER THAN THE OUTSIDE DIAM OF PIPE. THROUGH - PENETRANT - ONE METALLIC PIPE, CONDUIT OR TUBING TO BE CENTERED WITHIN THE FIRESTOP SYSTEM . AN ANNULAR SPADE OF 3/4 IN. 15 REQUIRED WITHIN THE FIRE5TOP SYSTEM. PIPE CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH 51DE5 OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED; A. STEEL PIPE - NOM 12 IN. DIAM ( OR SMALLER ) SCHEDULE 10 ( OR HEAVIER ) STEEL PIPE. B. CONDUIT - NOM 6 IN. DIAM (OR SMALLER) ELECTRICAL METALLIC TUBING OR STEEL CONDUIT. G. COPPER TUBING - NOM 6 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. D. COPPER PIPE - NOM 6 IN. DIAM ( OR SMALLER ) REGULAR ( OR HEAVIER ) COPPER PIPE. FILL, VOID OR CAVITY MATERIAL5* - SEALANT - MIN. 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL ASSEMBLY. MINNE50TA MINING AND MFG. CO. - FB -2000+ *BEARING THE UL CLASSIFICATION MARKING. TREMstop WS and TREMstop MCR. CAJ 2068 F- Rating = 21-Iour T - Reitim : 714em,r 6 2 a O PRE -RATED CONCRETE FLOORS OR BLOCKB WALL5 - MIN. 1 -1/2" THICKNESS. O 2 PLASTIC PIPE WO, (OR SMALLER) 56H. 40 PVC PIPE FOR USE IN CLOSED OR OPEN PIPING SYSTEMS. A MAX. ANNULAR SPACE OF 5/8" 15 REQUIRED. O TREM STOP WS - INSTUME5GENT WRAP STRIP5, CONTINU05LY WRAPPED AROUND OUTER CIRCUNFERENCE OF THE PIPE IN TWO STACKS OF TWELVE WRAP5. ( 4) TREM STOP MGR - PREFABRICATED STEEL COLLAR WRAPPED OVER THE WRAP STRIPS ( ITEM 3) AND MECHANICALLY FASTENED TO THE FLOOR OR WALL ASSEMBLY. O TREM STOP WBM OR FYRE -51L - MIN. I /4' BEAD OF SEALANT APPLIED AT THE INTERFACE OF THE CONCRETE SLAB AND STEEL COLLAR, AND AT THE INTERFACE OF THE STEEL COLLAR AND PIPE. O MORTAR - MIN. 4-1/2" THICKNESS OF MORTAR OR HYDRAULIC CEMENT APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF FLOOR OR WALL ASSEMBLY. NOTE : IN FLOORS, APPLY BELOW THE CONCRETE SLAB. IN WALL5, APPLY TO EACH 5IDE OF ASSEMBLY. ROO TYPE OF A55EMBLY: - PEDICURE SALON (GROUP B) exit sign w/- battery back up CONSTRUCTION TYPE: - TYPE IIB UN5PRINKLERED a� FLAME SPREAD: ■ AND q' -0' HIGH MAX (TYP) FINISH GLA55: = GLA55 'G' FINI J FE REQUIRED - 788/2500 =1 REQUIRED AFF TO HANDLE (I FE PROVIDED) co SMOKE DEVELOPMENT = 0-450 IF THE ADDRE55 15 PLACE ON THE STOREFRONT OCCUPANCY TAB THE NUMBERS SHALL BE WHITE. INHEN PLACED ON TENANT SPACE ("188 /100) = IF A LIGHT COLORED BACKGROUND THE COLOR SHALL BE BLACK. TOTAL OCCUPANCY : TP ALL 51615 AND LETTERING SHALL BE APPROVED EX MASONRY WALL W/- BY LANDLORD. STUCCO FIN ON EXTERIOR AND DRYWALL FURRING EX IHR f WALL FF CEILING EX IHF WALL GEILIN EX IHR FIRE RATED WALL FROM FLR TO CEILING ( IHR FIRE RATED 4LL FROM FLR TO TILING n L D J n EX IHR FIRE RATED WALL FROM FLR TO CEILING DEMO FLOOR PLAN showing existing conditions 50ALE: 1 /4"- I' -0" PRIOR USED: (GROUP B) EX MASONRY WALL TO REMAIN PERMITTED EX INTERIOR STUD WALL TO REMAIN PERMITTED EX NON BEARING 1 HR RATED WALL PERMITTED NEW INTERIOR STUD WALL TO BE PERMITTED no pentration of fire wall in ADDRESS AND PLACE ON DOOR IN 6" HIGH LETTERS EX 1/2" TAPERED STEE DOWN AV EX (2)24'x80" INSUL MTL DOOR TO REMAIN 4 0 T r N N 9 n DURESS OM AND PLACE VEX 6 x80" ALUM FRAMED N DOOR IN 6' HIGH GLA DOOR ertERS PROPOSED FLOOR PLAN SCALE: 1/4' =1' -0" PROPOSED USED: BEAUTY SALON (GROUP B) 10' -O' GEILIN6 PIEI.D vERI PROVIDE 2 "xs YO BLOGKIN& 6RA5 RAILS TO WITHSTAND 250# MIN 3 5/8 229a mtl track ® 4' -0' off 3 5/8" 256A MTL. TRACK FASTEN TO FLR W/- 3/4" — POWER ACTUATED PINS 24" 0 /G. ACOUSTIC CEILING 3 5/8" 256A MTL. STUDS ® I6" O.G. W/ I LAYER OF I /2" GYP. BOARD ON EACH 5IDE 50REY ED TO STUDS NU- DRYWALL SCREWS ® 12" 0 10. CHEDULED BASE SCHEDULED FLOOR FIN (I�TYP STUD WALL Q "`5 SCALE: 1 /4" -1' -O" 1� LL LL F- z rev. clescription 6 I date SECTION A -A WALL A55EMBLY - THE FIRE RATED GYPSUM WALLBOARD /STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U -300 OR U-400 SERIES WALL AND PARTITION DE516% IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CON515T OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OG. STEEL STUDS TO BE MIN. 3 -5/8 IN. WIDE AND SPACED MAX. 24 IN. OG. B. WALLBOARD, GYPSUM* - NOM 5/8 IN. THICK GYPSUM YrALLBOARD, AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. DIAM OF OPENING 15 1 -1/2 IN. LARGER THAN THE OUTSIDE DIAM OF PIPE. THROUGH - PENETRANT - ONE METALLIC PIPE, CONDUIT OR TUBING TO BE CENTERED WITHIN THE FIRESTOP SYSTEM . AN ANNULAR SPADE OF 3/4 IN. 15 REQUIRED WITHIN THE FIRE5TOP SYSTEM. PIPE CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH 51DE5 OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED; A. STEEL PIPE - NOM 12 IN. DIAM ( OR SMALLER ) SCHEDULE 10 ( OR HEAVIER ) STEEL PIPE. B. CONDUIT - NOM 6 IN. DIAM (OR SMALLER) ELECTRICAL METALLIC TUBING OR STEEL CONDUIT. G. COPPER TUBING - NOM 6 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. D. COPPER PIPE - NOM 6 IN. DIAM ( OR SMALLER ) REGULAR ( OR HEAVIER ) COPPER PIPE. FILL, VOID OR CAVITY MATERIAL5* - SEALANT - MIN. 5/8 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL ASSEMBLY. MINNE50TA MINING AND MFG. CO. - FB -2000+ *BEARING THE UL CLASSIFICATION MARKING. TREMstop WS and TREMstop MCR. CAJ 2068 F- Rating = 21-Iour T - Reitim : 714em,r 6 2 a O PRE -RATED CONCRETE FLOORS OR BLOCKB WALL5 - MIN. 1 -1/2" THICKNESS. O 2 PLASTIC PIPE WO, (OR SMALLER) 56H. 40 PVC PIPE FOR USE IN CLOSED OR OPEN PIPING SYSTEMS. A MAX. ANNULAR SPACE OF 5/8" 15 REQUIRED. O TREM STOP WS - INSTUME5GENT WRAP STRIP5, CONTINU05LY WRAPPED AROUND OUTER CIRCUNFERENCE OF THE PIPE IN TWO STACKS OF TWELVE WRAP5. ( 4) TREM STOP MGR - PREFABRICATED STEEL COLLAR WRAPPED OVER THE WRAP STRIPS ( ITEM 3) AND MECHANICALLY FASTENED TO THE FLOOR OR WALL ASSEMBLY. O TREM STOP WBM OR FYRE -51L - MIN. I /4' BEAD OF SEALANT APPLIED AT THE INTERFACE OF THE CONCRETE SLAB AND STEEL COLLAR, AND AT THE INTERFACE OF THE STEEL COLLAR AND PIPE. O MORTAR - MIN. 4-1/2" THICKNESS OF MORTAR OR HYDRAULIC CEMENT APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF FLOOR OR WALL ASSEMBLY. NOTE : IN FLOORS, APPLY BELOW THE CONCRETE SLAB. IN WALL5, APPLY TO EACH 5IDE OF ASSEMBLY. ROO exit sill and emergency lite combo w/- battery back -up ® exit sign w/- battery back up EMERGENCY LITE W/ - BATTERY a� BACK -UP AND SPACE 20' -0' APART ■ AND q' -0' HIGH MAX (TYP) (� 2A20BG FIRE EXTINGHJISHER J W/ -A MAX OF 20lbs. MTV ® 48" O AFF TO HANDLE co v t/ C LL �IL d U + 0 I E r� Z11 tL3 0 o `�U� ti N C m O I.L W 0 -1 -C W >-i ♦ W n ,- . 1 0■■■ ■000013■■■ ■000000■■■ °• 0■■■ ■0■■ ■0■■■ ■0■■0013■■■ . o■■■■o■■■o■■■ ■o■■■ ■o■■■ • o■ ■■■o■ ■■o■■■■oo■■Eo■■■ ■■■■■■■■■■■■■■■■■■■■■■■ Qp exit sill and emergency lite combo w/- battery back -up ® exit sign w/- battery back up EMERGENCY LITE W/ - BATTERY a� BACK -UP AND SPACE 20' -0' APART ■ AND q' -0' HIGH MAX (TYP) (� 2A20BG FIRE EXTINGHJISHER J W/ -A MAX OF 20lbs. MTV ® 48" O AFF TO HANDLE `el k'Lj. F,� f L 1\ n ■ a� V ■ C 0 O 0 co v t/ C LL �IL d U + 0 I E r� Z11 tL3 0 o `�U� ti N C m `el k'Lj. F,� f L CORRECTE B UILDING t I Job no sheet: ACOUSTIC CEILING SCHEDULE NO. ACT -1 REPLACE STANDARD 2'X 4' TEGULAR TILE5; 10' -0" AFF n ■ a� V ■ C 0 o C 0 co v t/ C CORRECTE B UILDING t I Job no sheet: ACOUSTIC CEILING SCHEDULE NO. ACT -1 REPLACE STANDARD 2'X 4' TEGULAR TILE5; 10' -0" AFF c i s I SYSTEM No W -L 1084 F-Rating � I Hour T- Rating w 0 Hour PART ELEV OF ARCH NICHE EX REFLECT CEILING PLAN n ■ co C C N U 0 ICU N C m O I.L W 0 -1 -C W >-i ♦ W c i s I SYSTEM No W -L 1084 F-Rating � I Hour T- Rating w 0 Hour PART ELEV OF ARCH NICHE EX REFLECT CEILING PLAN rev. NN DOWN 5TREAM WC STUB UP HANGER ROD SCHEDULE PIPE SIZE ROD SIZE PIPE SIZE ROD SIZE UP TO 2" 3/8" DIA 4" TO 6" 5/8" PIA, 2 -1/2" TO 3" 1/2" DIA 6" TO 12" 1/8" DIA. 6y 1 elate WE5 MEh IBERS ONE ANGLE ON EACH WELDS HANGER NUT SIDE OF WE5 MEM5ERS SENT STRAP 1 -1/2" X REST ON TOP OF 3/16" OVER VERT 50TTOM CHORDS STEEL LEGS OF ANGLES JOISTS BETWEEN PANEL POINTS, SIZE FOR LOAD 50TTOM CHORDS OF STEEL JOIST STEEL JOIST HEAVY DUTY CONCRETE • i . °• STEEL INSERT WITH • $•• ELONGATED STRAP HANGER ROD —► SUPPORT NUT HEAVY DUTY INSERT N HANGER ROD CLEVIS HANGER PIPE CONCRETE INSERT + ti CLEVIS HANGER — - -- - - - - -- - - - _ — SING=LE HORIZONTAL RUNS ': R SHOUN 0 ALL EXPO5ED HOT WATER PIPES 5HALL BE INSULATED NO VAPOR BARRIER INSUL ,.�; o HANGER ROD HEAVY DUTY CONC O 0 LOCKING NUT JOIST CLAMP � TABLE 1` SUPPORT NUT HANGER ROD 5LOPE OF HORIZONTAL DRAINAGE PIPE HEAVY DUTY L CLEVIS HANGER CONCRETE JOIST - VAPOR 5ARRIER �^ � J SIZE (inches) MINIMUM SLOPE (inch per foot) 3 to 6 I/8 16 GA ZINC COATED 5EAM (SEE PROJECT tom--• d L INSULATION `. 2 -1/2 or less 1/4 STRUCTURAL S i EEL 4, Y SHEET STEEL SADDLE HEAVY F i 8 or larger 1/16 AT LEAST 8" LONG CLEVIS HANGER CLAMP Z m U For 51: 1 Inch = 25.4 mm, I Inch per foot = 0.0835 mm /m. EYE SOCKE T A LL - o SINGLE HORIZONTAL RUNS WITH VAPOR BARRIER INSUL HANGER RO �, STEEL BEAM PIPE STANDARD USED PER TABLE 605.4 & 702.2 & 402.4(2) Chlorinated polyVlnyl chlorlde A5TM D 2846; A5TM F 441; A5TM F 442 POTABLE WATER (CPVC) plastic pipe r fIn Chloride (PVC) Plastic A5TM D 2665; A5TM D 294q; 05A 8181.2 5EAER LINE pe DWV) NOTE5: I. HOT WATER TO HAND SINKS AND TOILET ROOMS SHALL NOT EXCEED 110 DECGREE5 PER FAG 4.12.1 AE3GD 2.5.2 2. ALL PLUMBING FIXTURES 5HALL COMPLY WITH 1`5C TABLE 604.5 4 604.4 6 "W WWM IN CONC I// TO 5EWER PIPE — YV- 1/8" FALL PER FOOT RUN WATER SUPPLY ISO WATER PIPING 5HALL BE INSTALLED IN ACCORDANCE A- FBC P -TABU 603.1 , 6043, 604.4, 6045. AND 604.10.1 RATER HAMMER ARRESTOR 5HALL BE IN5TALLED FOR GUICK CLOSING VALVES. � fit° rv. � ;y c A i L� CA drawn by: mf checked by: J. Biagi date: 07 -16 -14 job no: sheet PLUMBING LAYOUT 50ALE: 1/4 " =1' -0" 0 / -6 MILL VAPOR BARRIER EX GONG SLAB 5AA CUT TO MAKE PLUMBING TRENCH 12" WIDE PLUMBING TRENCH 10" DEEP MIN AND COMPACTED YNV CLEAN SAND FILL PLUMBING TRENCH DETAIL Qz � m N U 0 � n E o - Cu�-C � W w n, O N z 6 5 N O N o CL ._ M °� C o o drawn by: mf checked by: J. Biagi date: 07 -16 -14 job no: sheet PLUMBING LAYOUT 50ALE: 1/4 " =1' -0" 0 / -6 MILL VAPOR BARRIER EX GONG SLAB 5AA CUT TO MAKE PLUMBING TRENCH 12" WIDE PLUMBING TRENCH 10" DEEP MIN AND COMPACTED YNV CLEAN SAND FILL PLUMBING TRENCH DETAIL MECHANICAL. NOTES 1. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY FOR THE INSTALLATION OF A COMPLETE SYSTEM IN ACCORDANCE WITH THESE DRAWINGS, THE APPLICABLE BUILDING CODE AND ALL OTHER APPLICABLE STATE, COUNTY AND LOCAL ORDINANCES AND THE LATEST ADDITION OF THE FOLLOWING PUBLICATIONS; SMACNA, ASHRAE, NFPA 90A, 90B, 91 & ANSI B -9.1 MECHANICAL REFRIGERATION. 2. THE CONTRACTOR SHALL PAY ALL COSTS OF PERMIT, INSPECTIONS AND ALL OTHER COSTS INCIDENTAL TO THE COMPLETION AND TESTING OF THIS WORK. 3. THE CONTRACTOR SHALL VISIT THE SITE AND COORDINATE WORK WITH OTHER TRADES. 4. THE CONTRACTOR SHALL SUPPLY THE ARCHITECT WITH "AS- BUILT" DRAWINGS. 5. CONTRACTOR SHALL SUBMIT, FOR APPROVAL FIVE [5] COPIES OF MANUFACTURER'S DRAWINGS FOR EACH PIECE OF EQUIPMENT AND CONTROLS INCLUDED IN CONTRACT. 6. ALL MATERIAL SHALL BE NEW OF U.S. MANUFACTURER OF GOOD QUALITY. ALL WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER BY SKILLED WORKMAN. 7. ALL AIR CONDITIONING DUCT WORK SHALL BE OF 1-1/2" (R -6) STANDARD DUTY FOIL REINFORCED FIBERGLASS WITH MANUFACTURER'S LOGO PRINTED ON VAPOR BARRIER ALL FLEX TO BE R -6. 8. ALL EXHAUST DUCTS AND OUTSIDE AIR DUCTS SHALL BE GALVANIZED SHEET METAL WITH SEALED SEAMS AND JOINTS. 9. DUCT SIZES SHOWN ARE INSIDE DIMENSIONS. 10. ALL AIR DEVICES (DIFFUSERS, REGISTERS AND GRILLES) SHALL BE ALL ALUMINUM CONSTRUCTION WITH EXPOSED SURFACE OFF WHITE BAKED ENAMEL FINISH TO MATCH EXISTING OR AS SPECIFIED BY ARCHITECT. DEVICES SHALL BE TITUS, METALAIRE AIRGUIDE. PROVIDE OPPOSED BLADE DAMPERS AT ALL DIFFUSERS AND REGISTERS. 11. THERMOSTAT SHALL BE COMBINATION COOLING /HEATING, WITH SYSTEM "COOL -AUTO- HEAT -OFF" AND FAN "ON -AUTO" SELECTOR SWITCHES. PROVIDE PROGRAMMABLE TYPE, I pbQ IY*EWEVPtI� - •Fb�OXLQEATK�W DID KGCPdE LENT BEFORE STARTING 12. THEM. REPLACE THEM PRIOR TO FINAL ACCEPTANCE BY OWNER. 13. PROVIDE SMOKE DETECTORS WITH ACCESS DOORS IN ALL SUPPLY AIR DUCTS FOR FANS AND AHU'S SERVING A COMMON PLENUM OF 2000 CFM OR ABOVE. ALL SMOKE DETECTORS SHALL BE BY ONE MANUFACTURER, COORDINATE VOLTAGE ETC. WITH ELECTRICAL CONTRACTOR AND FIRE ALARM SYSTEM BEFORE ORDERING. UPON DETECTION, SMOKE DETECTORS SHUT DOWN ASSOCIATED AIR MOVING EQUIPMENT AND ALL AIR MOVING EQUIPMENT SERVING THAT COMMON PLENUM. 14. PROVIDE TYPE "B" FIRE DAMPERS IN ALL DUCTS OR OPENINGS PENETRATING FIRE RATED WALLS, MECHANICAL AND ELECTRICAL EQUIPMENT ROOMS, TENANT SEPARATION, PARTITIONS, FLOOR OR ROOF SLABS AND AT 0/A INTAKES. PROVIDE RADIATION RADIATION DAMPERS IN RATED CEILINGS FOR ALL CEILING OPENINGS, CEILING FANS, DIFFUSERS OR GRILLES RATED FOR USE IN THE CEILING ASSEMBLY. 15. THERMOSTAT LOCATION SHALL BE APPROVED BY OWNER AND ENGINEERS BEFORE DUCT SMOKE DETECTOR NO INSTALLATION. NO 16. PROVIDE A MIN. OF 3' CLEARANCE IN FRONT OF ALL 120 -240 VOLT PANELS AND 4' NO CLEARANCE IN FRONT OF ANY 480 VOLT PANEL. PROVIDE ADEQUATE SIDE FIRE STOPING NO CLEARANCE PER NEC. NO 17 MECHANICAL PLANS IN GENERAL, ARE DIAGRAMMATIC IN NATURE, AND ARE TO BE READ • IN CONJUNCTION WITH ARCH. PLUMBING, ELECTRICAL AND STRUCTURAL PLANS AND NEW DUCTWORK SHALL BE CONSIDERED AS ONE SET OF DOCUMENTS. DUCT AND PIPING OFFSETS, BENDS CONDENSING UNIT AND TRANSITIONS WILL BE REQUIRED TO PROVIDE AND INSTALL A COMPLETE MOCP OR GRILLE WALL TYPE (AIR INTO FUNCTIONAL SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO DEVICES) �u. ADDITIONAL COST TO THE OWNER. 1 � 18. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO BIDDING, ORDERING, INCLINED DROP IN DIRECTION FABRICATION OR INSTALLATION OF MATERIALS OR EQUIPMENT. OF AIR FLOW, FLAT BOTTOM 19 . NO COMBUSTIBLE MATERIALS ARE ALLOWED IN RETURN AIR PLENUMS OR ABOVE REG ROOF EXHAUST FAN CEILINGS USED AS RETURN AIR PLENUM. IF SPACE WITH RETURN AIR PLENUM EXHAUST FAN ma HAS ANY DECK TO DECK PARTITIONS, AIR TRANSFER DUCTS MUST BE INSTALLED. FC 20. THIS IS A REMODEL OF AN EXISTING SPACE. CONTRACTOR TO VISIT SITE PRIOR TO BID. mi I MECHANICAL NOTES DESIGN REQUIREMENTS REQUIRED DUCT SMOKE DETECTOR NO FIRE DAMPER(S) NO SMOKE DETECTOR NO FIRE RATED ENCLOSURE FIRE RATED R OOF /FLO OR NO NO FIRE STOPING NO SMOKE CONTROL NO MZ I SAC DESIGN REQUIR$MENTS LEGEND ® NEW SUPPLY AIR CEILING DIFFUSER ''v NEW RETURN AIR CEILING GRILLE -vu /c WALL LOUVER / WALL DIFFUSER. ` FIRE DAMPER, ALL FIRE DAMPERS AHU SHALL BE FIRE SMOKE DAMPERS ` FIRE SMOKE DAMPER NOT ALL SYMBOLS MAY VOLUME CONTROL DAMPER Q THERMOSTAT Q HUMIDISTAT • NEW FLEX DUCT NEW DUCTWORK -► SUPPLY TOP REGISTER (WALL TYPE) CONDENSING UNIT RETURN OR EXHAUST TOP REGISTER MOCP OR GRILLE WALL TYPE (AIR INTO EWT DEVICES) �u. INCLINED RISE IN DIRECTION 1 � OF AIR FLOW, FLAT BOTTOM INCLINED DROP IN DIRECTION RETURN AIR OF AIR FLOW, FLAT BOTTOM e DIFFUSER OR GRILLE DESIGNATION REG ROOF EXHAUST FAN 4 OR a EXHAUST FAN ma FLEXIBLE CONNECTION FC FSD FIRE SMOKE DAMPER DUCT TURN WITH TURNING VANES VCD - PROVIDE ALL SQUARE OR AD RECTANGULAR ELBOWS WITH VANES t' EVEN IF SYMBOL IS MISSING RETURN AIR GRILLE STANDARD RADIUS ELBOW, ROUND FIRE DAMPER DUCT ALL SQUARE OR RECTANGULAR SAR ELBOWS WITH VANES EVEN IF SYMBOL IS MISSING. ®UP SUPPLY & OUTSIDE AIR SECTION (UP) M DN SUPPLY & OUTSIDE AIR SECTION (DOWN) UP RETURN & EXHAUST DUCT SECTION (UP) = DN RETURN & EXHAUST DUCT SECTION (DOWN) ''v RETURN AIR -vu /c DOOR UNDER CUT -; SUPPLY AIR AHU AD - ACCESS DOOR ODD DUCT SMOKE DETECTOR NOT ALL SYMBOLS MAY CD APPLY TO THESE PLANS MECHANICAL/HVAC LEGEND & M3 ABBREVIATION; N.T.S. INTERLOCK EF WITH AN OVEI SO THAT EF- WHEN RTU -1 AND OVERRIDI ALLOW TURNIP 1. RUN DUCT IN AT GROUND L 2. UP TO ABOVE TO EF -2 3. FROM EF-2T 4. INSURE MINIM( OUTSIDE AIR 5. PROVIDE 6 (6 EACH SIDE OF BETWEEN CHAI 6. COORDINATE C LOCATION WITI• FIRE WALLS IN DUCT PATH AND NO FIRE DAMPERS )UIRED EXCEPT WHERE OTHERWISE SHOWN ON THE PLAN ;T LAYOUT TO REMAIN AS IS, CEILING DIFFUSERS TO 4AIN, CONTRACTOR TO ADJUST FLEX DUCT IF NEEDED. ROOF PENETRATIONS MUST BE PERFORMED BY IDLORD APPROVED ROOF CONTRACTOR -2 HUNG FROM 2 "X2" ANGLE IRON SUPPORTS WITH ZING TYPE VIBRATION HANGERS 1 -1 EXISTING TO REMAIN BARD P113OA2 JTRACTOR TO MAINTAIN EXISTING UNIT AND ENSURE )PER OPERATION TO SATISFY THIS PLAN AND CONSULT H ENGINEER IN CASE OF DISCREPANCY V EXHAUST FAN AND EXHAUST DUCT AS PER THIS PLAN. 130A2, 3 TONS) NO TH MECHANICAL FLOOR PLAN SCALE: 1/4" = 1' -0" v e,. '. � ` o� - t ss 9 �: 9, aI4�+13s,o, ,0, 20 Y 0 REVISIONS ABBREVIATION AFF ABOVE FINISH FLOOR F/A FRESH AIR AHU AIR HANDLING UNIT GPM GALLONS PER MINUTE CD CONDENSATE DRAIN GR GRILLE CD CEILING DIFFUSER MCA MINIMUM CIRCUIT AMPS (FOR WIRE SIZING) CU CONDENSING UNIT MOCP MAXIMUM OVERCURRENT PROTECTION DEVICE AMPS EWT ENTERING WATER TEMPERATURE LWT LEAVING WATER TEMPERATURE EAG EXHAUST AIR GRILLE R/A RETURN AIR EF EXHAUST FAN REG REGISTER EXH EXHAUST SP SAFE PAN FSD FIRE SMOKE DAMPER VCD VOLUME CONTROL DAMPER AD ACCESS DOOR t' RAG RETURN AIR GRILLE FD FIRE DAMPER SAR SUPPLY AIR REGISTER 0/A OUTSIDE AIR MECHANICAL/HVAC LEGEND & M3 ABBREVIATION; N.T.S. INTERLOCK EF WITH AN OVEI SO THAT EF- WHEN RTU -1 AND OVERRIDI ALLOW TURNIP 1. RUN DUCT IN AT GROUND L 2. UP TO ABOVE TO EF -2 3. FROM EF-2T 4. INSURE MINIM( OUTSIDE AIR 5. PROVIDE 6 (6 EACH SIDE OF BETWEEN CHAI 6. COORDINATE C LOCATION WITI• FIRE WALLS IN DUCT PATH AND NO FIRE DAMPERS )UIRED EXCEPT WHERE OTHERWISE SHOWN ON THE PLAN ;T LAYOUT TO REMAIN AS IS, CEILING DIFFUSERS TO 4AIN, CONTRACTOR TO ADJUST FLEX DUCT IF NEEDED. ROOF PENETRATIONS MUST BE PERFORMED BY IDLORD APPROVED ROOF CONTRACTOR -2 HUNG FROM 2 "X2" ANGLE IRON SUPPORTS WITH ZING TYPE VIBRATION HANGERS 1 -1 EXISTING TO REMAIN BARD P113OA2 JTRACTOR TO MAINTAIN EXISTING UNIT AND ENSURE )PER OPERATION TO SATISFY THIS PLAN AND CONSULT H ENGINEER IN CASE OF DISCREPANCY V EXHAUST FAN AND EXHAUST DUCT AS PER THIS PLAN. 130A2, 3 TONS) NO TH MECHANICAL FLOOR PLAN SCALE: 1/4" = 1' -0" v e,. '. � ` o� - t ss 9 �: 9, aI4�+13s,o, ,0, 20 Y 0 REVISIONS d 0 w Z O U Q a Q .a CG a x� w� a z a, o oz 0 m 0 v DRAWN RRY CHECKED RRY DATE FEB. 4TH 2015 SCALE AS SHOWN JOB NO. 15 -005 SHEET TITLE MECHANICAL FLOOR PLAN SHEET NO. I 2 9F 4 f; t' l • d 0 w Z O U Q a Q .a CG a x� w� a z a, o oz 0 m 0 v DRAWN RRY CHECKED RRY DATE FEB. 4TH 2015 SCALE AS SHOWN JOB NO. 15 -005 SHEET TITLE MECHANICAL FLOOR PLAN SHEET NO. I 2 9F REVISIONS 1 1/2" MIN • SHEET METAL "EXHAUST DUCT • 1 1 1/2" BAND CLAMP :STEEL HANGER WIRE SPIN COLLAR TYPICAL TO TYPICAL CEILING CABINET FLEXMASTER CB OR CBD EXHAUST FAN WITH BACKDRAFT DAMPER, LOW NOISE LEVEL AND N❑ VIBRATION. MAX SPACING NOT TO EXCEED 5' WITH SAG NOT TO EXCEED 1/2" PER FOOT OVER 5' INTERVAL FRf1NT FACF GRTI I F WTTH GAUGE THK. 1" STRAP MAXIMUM FASTENING SCREENS CAPABILITY LOAD 24 .028 840 168 1. ALL VANED ELBOWS SHALL BE CONSTRUCTED AND 22 .034 1070 216 INSTALLED AS DETAILED BY SMACNA. EXHAUST FAN HANGING 20 040 1298 259 2• WHEN W, DOES NOT EQUAL W2 VANE SHALL BE SINGLE VANE .TYPE REGARDLESS OF W DIMENSION. ° 3. ALL SINGLE VANES SHALL HAVE A 2 INCH RADIUS, G ELASTIC LIMIT ASSUMED 1 1/2 INCH MAXIMUM SPACE BETWEEN VANES AND A 30ksi; RECOMMEND MAX LOAD 3/4 INCH TRAILING EDGE. (20% OF YIELD STRENGTH), 4. WHEN W, EQUALS W2 AND W, IS GREATER THAN 20 NOTES: INCHES VANES SHALL BE DOUBLE VANE TYPE. 0 00 1, FLEX DUCT WITH EXTERNAL INSULATI ❑N AND VAPOR co BARRIER JACKETING TYPICAL TO "FABRIFLEX" 2. "INSPECT ❑R SERIES" SPIN DOORS (� MSUPPORT REQUIREMENTS FOR FLEX DUCT /(''J SQUARE VANED ELBOW DETAIL CEILING MOUNTED CABINET EXHAUST DETAIL 4 N.T.S. M / NTS M N.T.S. �a COLLAR SUPPLY DUCT FLEX DUCT MAX. 12' -0" FLEX DUCT SIZE SHALL MATCH NECK SIZE CEILING HAND DAMPER OPPOSED BLADE o o DAMPER DRAW BAND WITH SILICONE SEALER CEILING DIFFUSER INSULATION CEILING DIFFUSER NOTE: A. FLEXIBLE DUCTWORK SHALL ONLY BE PERMITTED TO BE INSTALLED FOR FINAL VERTICAL CONNECTIONS TO DIFFUSERS. THE MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 5' FOR ANY ONE DIFFUSER CONNECTION. SYMBOL EF -1 EF -2 LOCATION 0 100 CFM BATH ROOMS ABOVE CEILING SERVICE _ BATH ROOMS OPEN AREA MAKE OR GR ORNEQU. MODEL SP -A -50 FG 10 250 CFM 50 400 �C.F.M. + S.P. J 0.1 INCHES 0,25 INCHES BLOWER DATA TYPE CEILING MOUNTED DUCT MOUNTED '— 600 CFM DRIVE DIRECT DIRECT a MECH HART & COOLEY H.P. 18 WATTS 133 W R.P.M. 700 3082 A V 120 120 C3 ELEC PH 1 1 H Z 60 60 INDUSTRIES INC. WT LBS, 15 12 DIMENSIONAL DATA 13•X1 • X11• 10• REMARKS SOUND ABSORBING INSULATION. SOUND ABSORBING INSULATION. PITCH ROOF CAP, PITCH ROOF CAP. E LECT ACCESS ELECT ACCESS FEB. 4TH 2015 OVER, COVER. BIRD SCREEN BIRD SCREEN SCALE VIBRATION VIBRATION ANGERS HANGERS AS SHOWN C ONTROL WITH CONTROL SWITCH IGHT SET FLANGE IN PLASTIC CEMENT SECURE TO ROOF AND CAULK It- WATERTIGHT ALL AROUND O ui ROOF CAP 8" M .a. • . • ��n. .�. - BIRDSCREEN ffi �. ROOF CAP W/ SEE ARCH, DWG, �' g BIRDSCREEN FOR ROOF CONSTRUCTION SEE PLAN FOR DUCT SIZE ROOF WALL SEE ARCH. DWG. FOR CONSTRUCTION b WALL CAP W/ m BIRDSCREEN �1 SEE PLAN FOR DUCT SIZE SEE PLAN FOR DUCT SIZE r l F� EXHAUST FAN SCHEDULE M1 N.T.S. ROOF & WALL CAP DETAIL TYPICAL DIFFUSER CONNECTION �1� /(Q MS N.T.S. �+ 1V1C� NTS � W RTU -1 TOTAL AREA: 100 SF OFFICE, 650 SF SALON. NUMBER OF PEOPLE: 18 (40 SF. PER PERSON,SALON) FRESH AIR REQUIRED: 18 x 20 + 650 x 0.12 = 438 CFM TOTAL OUTSIDE PROVIDED = 450 CFM *CALCULATIONS PERFORMED BASED ON ASHRAE STANDARD FOR SPECIALTY BUILDING FOR MAX. OCCUPANCY LESS THAN 3 HRS. ACCEPTABLE AIR QUALITY IS ACHIEVED WITHIN THE SPACE BY CONTROLLING KNOWN AND SPECIFIABLE CONTAMINANTS. VENTILATION RATE PROCEDURE= HAD BEEN USED TO ACHIEVED ACCEPTABLE INDOOR AIR QUALITY. THE DESIGN WILL NEED TO BE RE— EVALUATED IF, AT A LATER TIME, SPACE USE CHANGES OCCUR OR IF UNUSUAL CONTAMINANTS OR UNUSUALLY STRONG SOURCES OF SPECIFIC CONTAMINANTS ARE TO BE INTRODUCED INTO THE SPACE INCLUDING ENVIRONMENTAL CIGARETTES, PIPE OR CIGAR SMOKE. CHANGES IN SPACE USE, CONTAMINANTS, OR OPERATION MAY REQUIRE A RE— EVALUATION OF THE DESIGN AND IMPLEMENTATION OF NEEDED CHANGES. .rn RRRCTS OTT? CAT OT TT ATTnXTC SYMBOL FLEXIBLE DUCT DESIGN CFM RANGES DESCRIPTION FLEX SIZE IN CA) 0 100 CFM 6" 101 CFM 150 CFM 7" 151 CFM 180 CFM 8" 181 CFM 250 CFM 9" 251 CFM — 350 CFM 10° 351 CFM — 520 CFM 12" 521 CFM '— 600 CFM 14° OEM NUMBER OF PEOPLE: 18 (40 SF. PER PERSON,SALON) FRESH AIR REQUIRED: 18 x 20 + 650 x 0.12 = 438 CFM TOTAL OUTSIDE PROVIDED = 450 CFM *CALCULATIONS PERFORMED BASED ON ASHRAE STANDARD FOR SPECIALTY BUILDING FOR MAX. OCCUPANCY LESS THAN 3 HRS. ACCEPTABLE AIR QUALITY IS ACHIEVED WITHIN THE SPACE BY CONTROLLING KNOWN AND SPECIFIABLE CONTAMINANTS. VENTILATION RATE PROCEDURE= HAD BEEN USED TO ACHIEVED ACCEPTABLE INDOOR AIR QUALITY. THE DESIGN WILL NEED TO BE RE— EVALUATED IF, AT A LATER TIME, SPACE USE CHANGES OCCUR OR IF UNUSUAL CONTAMINANTS OR UNUSUALLY STRONG SOURCES OF SPECIFIC CONTAMINANTS ARE TO BE INTRODUCED INTO THE SPACE INCLUDING ENVIRONMENTAL CIGARETTES, PIPE OR CIGAR SMOKE. CHANGES IN SPACE USE, CONTAMINANTS, OR OPERATION MAY REQUIRE A RE— EVALUATION OF THE DESIGN AND IMPLEMENTATION OF NEEDED CHANGES. .rn RRRCTS OTT? CAT OT TT ATTnXTC SYMBOL SERVICE DESCRIPTION MFG. d- MODEL NO. RECTANGULAR CEILING DIFFUSERS HART & COOLEY A ALL ALUMINUM FACE CONSTRUCTION CEILING ONE —WAY AIR DIFFUSION MODEL NO. _ SUPPLY MULTI — SHUTTER OR OPPOSED BLADE DAMPERS A501MS REGISTERS BRIGHT WHITE FINISH SIZES SHOWN ON _ PLAN 450 ��c��a�o i .�44,� ©��� HART & COOLEY B RETURN BAKED WHITE ENAMEL :FINISH. RED MODEL e. SIZES SHOWN ON PLANS. — DIFFUSERS C EXHAUST LOUVERED FACEVENT LOUVER. SEIHO VENT ALUMINUM CONSTRUCTION, SURFACE MOUNT INDUSTRIES INC. LOUVER FINISH SHALL BE ANODIZED ALUMINUM. MODEL NO. DATE SIZES SHOWN ON PLANS SX w a q �o 0 i �m Iviv d- EXHAUST THRU EF -2 EXHAUST FROM TOILET -400 CFM -50 CFM RTU -1 _ 450 ��c��a�o i .�44,� ©��� DRAWN e. RRY CHECKED RRY 0 : _ DATE a! FEB. 4TH 2015 SCALE SALON a �0. ��� AS SHOWN JOB NO. 0.00 , ; tr e' a�a 15 -005 SHEET TITLE MECHANICAL DETAILS &SCHEDULE SHEET N0. 2 M6 FLEX DUCT SCHEDULE � AIR BALANCE DETAIL 1 AIR DISTRIBUTION t11CIDtG lV t 'oju of 2