Loading...
DRAWINGS15-4" MASONRY WALL /EXIST. AN EXIT 1/2" DRYWALL OVER 1X2 PT FURRING OVER MAS. WALL A COMPLIANT .. AFF BAY 8 "B" OCCUPANCY EXIST THRU 1 SINK TANKLESS WH m� DETAIL OF UNDER SINK MTD. TANKLESS WH NO DOORS OR WINDOWS ARE BEING ELIMINATED, OR RELOCATED AS PART OF TENANT IMPROVEMENT AND TENANT SEPARATION WALLS WILL NOT BE LOCATED WI , H N GLAZED D OPENINGS 00 NOT SUSPENO ANYTHING FROM ROOF DECK I EXISTIN3 1 HR RATED I 4" STUD WALL I I W/ 5/8" TYPE X DW EACH SIDE I I` FROM FL OR TO ROOF DECK I I i REF. # 4P 1070 OR WP 1 00 ( WITHOUT INSULATION) COVERED WALKWAY E-1 ------------------------------------------------------ BAY-9 938 sf SERVICE SINK LAV TANKLESS '%,TYP. SHUT OFF VALVE N IN HOT WATER RISER 4" MTL. EXHAUST 1/2" DRYWALL OVER 1X2 PT- EXISTING MASONRY WALL NrAN - - - - - - - V FURRING OVER MAS. WALL w� V `V WIRE SERVES TRIP 01 03 05 O7.18°.368 09 11 13 15 17 19 EXISTING METAL B f7f 72 4 1.4 ,18 .18 STUD W ` N I 1 I 40/2 10 WALLS W/ 1/2" 12 OW E.S. LIGHTING 12 WINDOWOUTLET20/1 20/1 LIGHTING 12 20/1 LIGHTING 12 VENILLA 0211111 OCEAN PALM 20/1 SIGN 600 N. FEDERAL HWY 20/1 METER R OM METER ROOM TTff 1 3— 3 I JOEL SIDNEY SCHULTZ, ARCHITECT LIC NO. AR0006707 DATE: E DRAWN BY: ' , ,� I I I I I i I 1 2.35 1 I A-1 CE X 3 ` I GF , "►10 A-2 , - - ❑ W I I I PROVIDE A C NV.OUTL MASONRY WALL �` = I UNIT SIGN AT 6 I �� I , I 1 � I I , I I I , I I , I H I ; I I , I I I I I I I rHr � I I , I I 1 . 1 .r I L I I I I � ,y , ' I , I I 1 I 1 I \ , , I ' 2" "° 3 0 6/ 8 I I 1 I / I I 1 d , , I 1 I € I NEW PARTITION 1 I / I , ' I , I , I I FINIISHED j , I I I I 1 I I I I 1 , , , I 1 1 1 I I I , , , I I I 3 1 1 I % '- , r - - - - - - - - - I , 1 I I 6 I I I , , , I I I EXISTING 1 HR RATED I I I i 4" STUD WALL , A W/ 5/8" TYPE X DW EACH SIDE I I -A � FROM FLOOR TO ROOF DECK � i , c r- - - - - - - - - - - -� 1 , REF. # WP 1070 OR WP 1200 (WITHOUT INSULATION) I I , I 1 I 0 10 i I "B"B OCCUPANCY w L= o I ij I o Z I , C:) i 1. 1 I O DIRECTION ji ';;�7---�7OF EGRESS I 1 3 a C-0 r If 36" ACCESS ; z ISLE I H Lu Lu , , LD I I I i; , ) I Lb z 1 I'' Cn X Lu , I I 1' I t , I , , X u.J 1/2" DRYWALL OVER 1X2 PT FURRING OVER MAS. WALL A COMPLIANT .. AFF BAY 8 "B" OCCUPANCY EXIST THRU 1 SINK TANKLESS WH m� DETAIL OF UNDER SINK MTD. TANKLESS WH NO DOORS OR WINDOWS ARE BEING ELIMINATED, OR RELOCATED AS PART OF TENANT IMPROVEMENT AND TENANT SEPARATION WALLS WILL NOT BE LOCATED WI , H N GLAZED D OPENINGS 00 NOT SUSPENO ANYTHING FROM ROOF DECK I EXISTIN3 1 HR RATED I 4" STUD WALL I I W/ 5/8" TYPE X DW EACH SIDE I I` FROM FL OR TO ROOF DECK I I i REF. # 4P 1070 OR WP 1 00 ( WITHOUT INSULATION) COVERED WALKWAY E-1 ------------------------------------------------------ BAY-9 938 sf SERVICE SINK LAV TANKLESS '%,TYP. SHUT OFF VALVE N IN HOT WATER RISER 4" MTL. EXHAUST 4 WIRE TALL EXISTING MASONRY WALL NrAN IT V `V WIRE SERVES TRIP 01 03 05 O7.18°.368 09 11 13 15 17 19 A QJ .72 4 1,2 B f7f 72 4 1.4 ,18 .18 C Ql ,55 1.8 02 04 06 08 10 12 14 16 18 20 TRIP 1 12 OUTLETS 20/1 40/2 10 12 OUTLETS 20/1 12 20/1 LIGHTING 12 WINDOWOUTLET20/1 20/1 LIGHTING 12 20/1 LIGHTING 12 VENILLA BOX OCEAN PALM 20/1 SIGN 600 N. FEDERAL HWY 20/1 METER R OM 20/1 TANKLESS WH GFI I x p I I I JOEL SIDNEY SCHULTZ, ARCHITECT LIC NO. AR0006707 DATE: E DRAWN BY: ' , SCALE: I I I MASONRY WALL 1 2.35 TOTAL A-1 CE ANG HGT.8 S 3 I I I GF , "►10 , - - I1 , R\OF TO C NV.OUTL RC\OF TOR AX UNIT I EXISTING I , � I I , I I I , I I , 6 Ilk" I , I I I I � , I , I I I I � ,y , ' I , I I 1 I 1 I \ , , I ' 2" BAR JOISTS I 1 / I I 1 d , , I 1 I € I / , ' I , I , I j , I I I I I 1 , , , I 1 1 1 , , , I 1 I % I , 1 I I 6 I , , , I I / I I I i , A 8� I I -A � � i I I , SHOW WINDOW OUTLET OVER WINDOW COVERED WALKWAY PANEL A 120/208 VOLTS, 3 PHASE'. 4 WIRE EXISTING PANEL WIRE SERVES TRIP 01 03 05 O7.18°.368 09 11 13 15 17 19 A QJ .72 4 1,2 B f7f 72 4 1.4 ,18 .18 C Ql ,55 1.8 02 04 06 08 10 12 14 16 18 20 TRIP SERVES 12 OUTLETS 20/1 40/2 ACU 12 OUTLETS 20/1 12 20/1 LIGHTING 12 WINDOWOUTLET20/1 20/1 LIGHTING 12 20/1 LIGHTING 12 VENILLA BOX OCEAN PALM 20/1 SIGN 600 N. FEDERAL HWY 20/1 LAV OUTLET GFI a. x 20/1 TANKLESS WH GFI I x p JOEL SIDNEY SCHULTZ, ARCHITECT LIC NO. AR0006707 DATE: 03-28-15 DRAWN BY: J.S.S SCALE: 6.47 1 6.53 1 2.35 TOTAL A-1 OTAL CONN. LOAD 15.35 KVAI 42.63 AMPS CONNECTED LOAD ET e 12 ILLUMINATED EXIT/EMERG. LIGHT ON BATTERY PACK' WIRED TO LIGHTING CIRCUIT AHEAD OF SWITCHES D ILLUMINATED EMERGENCY LIGHT ON BATTERY PACK (1V WIRED TO LIGHTING CIRCUIT AHEAD OF SWITCHES ® E. F. EXHAUST FAN W/ 4" GALV. PIPE THRU SIDE WALL STANDARD REFLECTOR SERIES SUSPENDED 2 TUBE (F32T8) FLUORESCENT FIXTURE LAMP WATTAGE 28 W FIXTURE WATTAGE 49 W 120 VOLT 46" LONG, 12" WIDE. 4" HIGH SUSPEND FIXTURES 10' FROM FLOOR FIXTURES SHALL BE SUSPENDED FROM BAR JOISTS USING UNISTRUT METAL FRAMING BETWEEN JOISTS c� MANUAL LIGHTING CONTROL SWITCH IY OCCUPANCY SENSOR LIGHTING CONTROL SWITCH $OS OR OPTIONAL TIMER CONTROLED LIGHT SWITCH 0 115 VOLT CONVENIENCE OUTLET LIGHTING ALLOWANCE PER F.E.C.: 938 SF X 0.9 W/SF = 844 W FOR OFFICE PROVIDED 15 FIXTURES AT 49 W EACH = 735 WATTS LOAD CALCULATION GENERAL LITES AT 3.5W/SF X 938 = 3283.5 W LIGHTING ADDITIONAL 125% = 624.4W AHU 8KW 8000W EMERG & EXIT 36OW HOT WATER 1800W SIGN 120OW TOTAL 15467.9/360 = 42.97 AMPS , EXIT AND EMERGENCY LIGHTS ON LIGHTIM0,, C AHEAD OF SWITCHES lira.APLI DESIGN CRITERIA • BASED ON FLORIDA BUILDING CODE 2014 5TH EDITION, TO INCLUDE ALL ACCOMPANYING 2014 5TH EDITION CODES )I( FLORIDA EXISTING BUILDING CODE 2014 5TH EDITION • NATIONAL ELECTRIC CODE 2011 EDITION DIE ALTERATION LEVEL 2 • OCCUPANCY CLASSIFICATION "B" ORDINARY HAZARD IN ACCORDANCE WITH NFPA 101 38.1.5 • CONSTRUCTION TYPE Vb • NUMBER OF STORIES: 1 NOT FIRE SPRINKLED FORMERLY B OR M OCCUPANCY I Structural EiM1J3r`fl i Fife ,._. Poiice- - BUSINESS OCCUPANCY LOAD processl;dbr. 817 SF G 100SF/OCC = 8 MAXIMUM TRAVEL DISTANCE 20OLF q ti , n r MAXIMUM COMMON TRAVEL DISTANCE 100 FT .ir, vnlw 1 EXIT REQUIRED UNDER 49 OCC.� ACTUAL MAX. TRAVEL DISTANCE 66' EXIT DOOR WIDTH REQUIREMENTS 8 X .2 = 1.6 FT ACTUAL 3' � �riill�■ �111111�_ a ALL FINISHES SHALL HAVE A FLAME SPREAD CLASSIFICATION OF C REVISIONS LL IDEAS DESIGNS ARRANGEMENTS AND PLANS INDICATED OR REPRESENTED BY THIS DRAWING RE OWNED AND COPYWRITED BY, AND THE PROPERTY OF THIS OFFICE AND WERE CREATED, VOLVED AND DEVELOPED FOR USE ON, AND N. CONNECTION WITH, THE SPECIFIED PROJECT NE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS R PLANS SHALL BE USED BY OR DISCLOSED D ANY PERSON, FIRM OR ENTITY FOR ANY URPOSE WHATSOEVER WITHOUT WRITTEN ERMISSION OF JOEL S. SCHULTZ ARCHITECT ITTEN DIMENSIONS SHALL HAVE PRECEDENCE ER SCALED DIMENSIONS. CONTRACTOR SHALL ERIFY AND BE RESPONSIBLE FOR THE ERIFICATION OF ACTUAL JOB CONDITIONS, ND SHALL REPORT DISCREPANCIES TO HE ARCHITECT PRIOR TO COMMENCEMENT F CONSTRUCTION. COPYRIGHT 2015 n e iOchuE! z a r c h i 1 e c -ARCHITECTURE- 13072 ISABELLA TERRACE DELRAY BEACH FLORIDA 33446 PH 954-895-2034 VENILLA BOX OCEAN PALM PLAZA UNIT 9 600 N. FEDERAL HWY BOYNTON BEACH FLORIDA a. x I x p JOEL SIDNEY SCHULTZ, ARCHITECT LIC NO. AR0006707 DATE: 03-28-15 DRAWN BY: J.S.S SCALE: AS NOTED PROJECT NO. SHEET NO. TOTAL A-1 Fire Rated Through Penetration Firestop for Single Plastic Pipe through Gypsum Walls using TREMstop IA. F -Rating = 2 Hr. T -Rating = 2 Hr. Kq UL/cUL System No. WL 2159 Pre -Rated Gypsum Wallboard/Stud Wall Assembly Plastic Pipe - Nom 2" diem. (or smaller) Sch. 40 PVC pipe for use in closed or open piping systems. The annular space range for 1-1/2" pipe is min. 1/4" to max. 5/8", and for 2" pipe the annular space range is min. 11/16" to Max. 15/16". TREMstop IA - Min. 1" thickness of sealant applied within opening. Additional sealant to be installed such that a min. 3/8" crown is formed around the penetrating item. NEW 4" THICK CONC SLAB ON 6 MIL POLY VAPOR BARRIER W/ 6X6 W1.4 X W1.4 WWM DWELS AT 24" C/C 5" INTO EXIST SLAB S L A B REPAIR D E I A I L NOT TO SCAL 48" MAX HGT OF DISPENSER OUTLE 36" REAR GRAB Bi 42" SIDE GRAB BC Q C ELEVATION A INSULATE ALL EXPOSED PLUMBING FIRE CAULK DRYWALL MEE 5/8" TYPE � 3-1/2" METt OPTIONAL Bt MIRROR INSULATE EXPOSED PIPE EXISTING 1 -HR RATED FIRE WALL PATCH ALL HOLES AND BRAKES IN FIRE RATED DRYWALL IN ACCORDANCE WITH GA -225-08 1. SQUARE OFF DAMAGED AREA 2. INSERT BACKING DRYWALL AND MECHANICALLY APPLY TYPE 5/8" X GYPSUM BOARD PATCH 3. TAPE AND SPACKLE REPAIRED AREA DAMAGED AREAS THAT EXCEED 100 SI SHALL BE REMOVED BACK TO FRAMING MATERIAL SO THAT NEW MATERIAL CAN BE ATTACHED DIRECTLY TO THE FRAMING MATERIAL ALL PATCH MATERIAL SHALL BE 5/8" TYPE X ALL PENETRATION IN FIRE WALL SHALL BE SEALED WITH APPROVED FIRE CAULKING AS REQUIRED BY UL AND AND INSTALLED PER MANUFACTURES RECOMMENDATION I X @ j C ,C, (0 E E E E E r N M N / 6" MAX TOE CLEARANCE 8" MIN KNEE CLEARANCE 17" MIN DEPTH ALL SINK CLEARANCES TOILET ROOM NOTES: 1 - ALL FIXTURES, CONTROLS, BARS, ETC. SHALL COMPLY W/ FLORIDA ACCESSIBILITY CODES SECTION 4.16 THRU 4.26. 2- ALL DISPENSING OUTLETS SHALL BE AT MAX 48" ABOVE FIN. FLOOR 3 - ALL TOILET ROOM FLOORS TO BE NON SLIP 4 - FLUSH LEVER SHALL BE ON SINK SIDE OF WATER CLOSET 5 - PROVIDE 3/4" PLYWOOD BACKING FOR GRAB BARS AND ACCESSORIES 6 - FLOOR AND BASE TO BE IMPERVIOUS SEE SINK CLEARANCE DETAIL ABOVE 42" 12" J U 1-1/2" GRAB BAR E a 0 J E L.I N 36" MAX Y 0 F (h H LL TP TP N O 2 O 1- t m M �1 SECTION TOILET PAPER DISP. TENANT SEPARA SECTION X=X GENERAL NOTES: 1. THE CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BIDDING AND SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO BEGINNING WORK. SHOULD ANY CONDITION ARISE WHERE THE INTENT OF THE DRAWINGS IS IN DOUBT, OR WHERE THERE IS DISCREPANCY BETWEEN THE DRAWINGS AND THE FIELD CONDITIONS, THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY FOR CLARIFICATION. 2. THE STARTING OF ANY WORK SHALL BE CONSIDERED AS PRIMA FACIA EVIDENCE THAT HE WAS INSPECTEO AND ACCEPTEO ALL CONDITIONS INVOLVED IN HIS WORK AND FINDS THEM SATISFACTORY. 3. DIMENSIONS TAKE PRECEDENCE. DIMENSIONS ARE TYPICALLY' TO COLUMN CENTER LINES. 4" STUD W/ DRYWALL WIDTH FACE OF CONCRETE OR MASONRY. OR AS NOTED ON PLANS. 4. THE CONTRACTOR SHALL TAKE THE NECESSARY PRECAUTIONARY MEASURES TO PROTECT THE PUBLIC AND ADJACENT PROPERTIES FROM DAMAGE THROUGHOUT CONSTRUCTION. 5. THE GENERAL CONTRACTOR SHALL MAINTAIN THE PREMISES IN A CLEAN AND ORDERLY FASHION DURING THE ENTIRE CONSTRUCTION PERIOD, REMOVING ALL TRASH FROM THE JOB SITE DAILY. ALL CONSTRUCTION DEBRIS MUST BE CONTAINED WITHIN THE TENANTS SPACE AND SHALL REMOVE SUCH DEBRIS AND CLEAN THE SPACE UPON COMPLETION. TEMPORARY TRASH STORAGE AND REMOVAL SHALL BE AT THE CONTRACTORS EXPENSE AND SHALL BE CONTAINED IN AN APPROVED TRASH CONTAINER LOCATED WHERE REQUIRED BY THE LANDLORD. 6. ALL DOORS SHALL BE OPENABLE IN THE DIRECTION OF EGRESS WITHOUT THE USE OF A KEY. TOOL OR SPECIAL KNOWLEDGE. 7. NO FASTENING DEVICES TO UNDERSIDE OF DECK WILL BE PERMITTED. ALL SUSPENSION FASTENING DEVICES SHALL BE SUSPENDED FROM STRUCTURE (JOISTS) WITH PROPER ANCHORAGE. 8. SOLID WOOD BACKING SHALL BE PROVIDED FOR ALL WALL MOUNTED SHELVING,DRINKING FOUNTAN AND BATHROOM GRAB BARS. S. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR. 10.INTERIOR FINISHES SHALL HAVE A MIN. FLAME SPREAD RATING OF CLASS "C" 11. THE CONTRACTOR SHALL PROVIDE DURING CONSTRUCTION. A PORTABLE FIRE EXTINGUISHER AS REQUIRED BY LOCAL CODES. 12. CONTRACTOR SHALL REPAIR ALL DAMAGED DRYWALL CAUSED BY THIS REMODELING 13. ANY WOOD IN CONTACT WITH CEMENT OR MASONRY SHALL BE PROTECTED FROM CONTACT WITH FELT PAPER OR BE PRESSURE TREATED. 1.5X6 1B GA MTL STUDS AT 24" C/C CLAD WITH MICA OR WOOD VENNER 2X6 TOP PL- DRAWER DESK (0 M TRACK TOP AND BOT N ANCHOR LOWER TRAC IN CONC. 3/4" PAF AT 24" C/C SECTION X—X THRU RECEPTION COUNTER SCALE 1/2" 1'-0" 30" 24" highest reach point X to P E P i SIDE REACH MAXIMUM SIDE REACH OVER OBSTRUCTION (2) 2X4 CONT. TOP PL 2X4 DRAFT STOP AT CLG. 2X4 DRAFT STOP EVERY 8' 2X4 WOOD STUDS P 24" C/C W/ 1/2" DRYWALL ES ANCHOR 2X4 PT SOLE PL TO SLAB W/ 3" X 1/4" TAPCONS AT 24" C/C 3. 7/16" N --I N BRUSHED ALUM. FINISH LEVER HANDLE PROFILA 1. DOOR TO BE 1-3/8" SOLID FLUSH MASONITE 2. ALL DOOR HARDWARE SHALL BE LEVER ACTION. SEE PROFILE 3. ALL DOORS SHALL BE OPENABLE FROM THE INSIDE OR IN THE DIRECTION OF EGRESS TRAVEL WITHOUT THE USE OF A KEY TOOLS OR SPECIAL KNOWLEDGE OR EFFORT. 4. ALL DOORS SHALL HAVE 32" MIN. CLEAR WIDTH WHEN OPEN REVISIONS I L IDEAS DESIGNS ARRANGEMENTS AND PLANS DICATED OR REPRESENTED BY THIS DRAWING E OWNED AND COPYWRITED BY, AND THE OPERTY OF THIS OFFICE AND WERE CREATED, OLVED AND DEVELOPED FOR USE ON, AND , CONNECTION WITH, THE SPECIFIED PROJECT NE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS PLANS SHALL BE USED BY OR DISCLOSED ANY PERSON, FIRM OR ENTITY FOR ANY RPOSE WHATSOEVER WITHOUT WRITTEN RMISSION OF JOEL S. SCHULTZ ARCHITECT ITTEN DIMENSIONS SHALL HAVE PRECEDENCE ER SCALED DIMENSIONS. CONTRACTOR SHALL RIFY AND BE RESPONSIBLE FOR THE RIFICATION OF ACTUAL JOB CONDITIONS, D SHALL REPORT DISCREPANCIES TO E ARCHITECT PRIOR TO COMMENCEMENT CONSTRUCTION. OPYRIGHT 2015 id na .� rf z architect -ARCHITECTURE- 13072 ISABELLA TERRACE DELRAY BEACH FLORIDA 33446 PH 954-895-2034 VENILLA BOX AT OCEAN PALM PLAZA UNIT 9 600 N. FEDERAL HWY BOYNTON BEACH FLORIDA P i IA P JOEL SIDNEY SCHULTZ, ARCHITECT LIC NO. AR0006707 DATE: 03-28-16 DRAWN BY: J.S.S SCALE: AS NOTED PROJECT NO. SHEET N0. TOTAL A-2 1-1/2" 26 GA GALV STRAP NAIL OR SCREW TO TRUSS SUPPORT EVERY 5 FT (MAX) TAPE TAB COLLAR TO DUCT BOARD DUCT WITH FOIL TAPE. SECURE INNER SLEEVE TO TAB COLLAR WITH "PANDUIT' STRAP AND FOIL TAPE. TAPE OUTER INSULATED SLEEVE TO DUCT BOARD WITH FOIL TAPE AND MASTIC. TAPE TAB COLLAR TO DUCT BOARD DUCT WITH FOIL TAPE. SECURE INNER SLEEVE TO TAB COLLAR WITH "PANDUIT' STRAP AND FOIL TAPE. TAPE OUTER INSULATED SLEEVE TO DUCT BOARD WITH FOIL TAPE AND MASTIC. BETWEEN DUCT & STRAP CEILING PLENUM OR SUPPY AIR DUCT TYPICAL FLEX DUCT SUPPORT DETAILS SCALE: NTS NOTE HANG DUCT PER SMACNA STANDARDS TYPICAL CHANNEL AND WIRE HANGER DETAIL TYPICAL DUCT SUPPORT DETAILS SCALE: NTS AIR CONDITIONING SYMBOLS YES NO --®-- i SUPPLY DIFFUSER �I vi RETURN DIFFUSER TOTAL BTUH: SMOKE DAMPERS EXHAUST FAN 26,000 ® PROG. THERMOSTAT HEAT: 6- MANUAL VOLUME DAMPER 1,200 ((( TURNING VANES SMOKE CONTROL REFRIGERANT LINE BATH EXHAUST ------------ CONDENSATE LINE CALCULATIONS: HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR RTU MODEL: �I FIRE DAMPERS 10.0 TOTAL BTUH: SMOKE DAMPERS SENSIBLE BTUH: 26,000 FIRE RATED ENCLOSURE 10,000 HEAT: FIRE RATED ROOF/FLOOR CEILING ASSEMBLY CFM: 1,200 FIlZE STOPPING 84 CFM SMOKE CONTROL EXISTING A/C EQUIPMENT EXISTING MAKE & TYPE: NO TAG - RTU EXISTING UNIT#: UNIT #9 RTU MODEL: 3.0 -TON (CONTRACTOR TO VERIFY) SEER: 10.0 TOTAL BTUH: 36,000 SENSIBLE BTUH: 26,000 LATENT BTUH: 10,000 HEAT: 5 kW CFM: 1,200 DUCT SIZING AND DESIGN ARE IN ACCORDANCE TO FMC 603.2 UTILIZING THE TRANE AIR DUCT CALULATOR AT 0.1 SP FOR S/A AND APPROX. 0.05 SP FOR R/A. SCOPE OF WORK: 1. EXISTING ROOFTOP PACKAGE UNIT TO REMAIN (A/C CONTRACTOR TO VERIFY SIZE) 2. ENSURE CONDENSATE DRAIN LINE TERMINATES TO PERMEABLE SOIL 12" FROM STRUCTURE 3. INSTALL PROGRAMMABLE THERMOSTAT 4. INSTALL SUPPLY DUCT AND GRILLES AS SHOWN. RETURN AIR IS AN OPEN RETURN 5. INSTALL NEW EXHAUST DUCT THRU BACK WALL MECHANICAL NOTES: DUCTING, PIPING, GRILLES & OTHER HVAC ITEMS SUCH AS EXHAUST FANS ARE DIAGRAMMATIC AND MAY BE ADJUSTED IN THE FIELD TO ACCOMMODATE FIELD CONDITIONS DUCTWORK SHALL HAVE MINIMUM OF R-6 INSULATION (PRESCRIPTIVE R-8) EXCEPTION: DUCTS OR PORTIONS THEREOF LOCATED COMPLETELY INSIDE THE BUILDING THERMAL ENVELOPE (SUCH AS, BETWEEN FLOORS OF CONDITIONED SPACES) MAY BE R-4.2 (FEC R403.2.1, EXCEPTION) DUCT SYSTEMS SERVING HEATING, COOLING AND VENTILATION EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF THIS SECTION AND ACCA MANUAL D OR OTHER APPROVED METHODS (2014-FBCR M1601.1 DUCT DESIGN) DUCT SUPPORTS (2014-FBCR M1601.4.3) NONMETALLIC DUCTS SHALL BE SUPPORTED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTION ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS HVAC SYSTEMS WILL UTILIZE THERMOSTATIC SET BACK CONTROLS USING A TIME CLOCK OR PROGRAMMABLE CONTROL SYSTEM TO AUTOMATICALLY SHUT DOWN COOLING & HEATING _.SYSTEMS (FEC C403.2.4.3) ALL HORIZONTAL PRIMARY CONDENSATE DRAINS WITHIN UNCONDITIONED AREAS SHALL BE INSULATED (FMC 307.2.5) FOR PVC DRAIN LINES ON ROOF TOP: MOUNT PVC CONDENSATE DRAIN TO BRICKS (OR PAVERS) WITH GALV METAL STRAP. PIPE STANDS MAY BE USED INSTEAD. SECURE TO ROOF DECK WITH ROOF ADHESIVE OR OTHER APPROVED METHOD. SPACE SUPPORTS EVERY 4 FEET MAXIMUM ROOFTOP PACKAGE UNITS MUST BE 10 FEET MINIMUM FROM ROOF EDGE OR SAFETY GUARDS MUST BE PROVIDED (SEE FBC-M 304.11 GUARDS) AC UNIT OUTSIDE AIR CALCULATIONS ROOFTOP PACKAGE UNIT FRESH AIR REQUIREMENTS FOR OFFICE SPACE TOTAL OFFICE SPACE: 942 SF TOTAL OCCUPIABLE FLOOR SPACE: 894 SF NUMBER OF PEOPLE: 5 PEOPLE / 1,000 SF = 894 / 1,000 x 5 = 4 FRESH AIR CALCULATION: 4 PEOPLE x 5 CFM / PERSON + 942 SF x 0.06 CFM / SF = 54 CFM FRESH AIR REQUIRED: 77 CFM OPEN O.A. DAMPER 7% FRESH AIR SUPPLIED: 84 CFM FRESH AIR DAMPERS THAT AUTOMATICALLY SHUT WHEN THE SPACES SERVED ARE NOT IN USE ARE REQUIRED AS PER FBC 503.2.5.3 AIR BALANCE SCHEDULE EQUIPMENT INTAKE O.D. AIR EXHAUST AIR RTU 84 CFM BATH EXHAUST 50 CFM CALCULATIONS: TOTAL OUTSIDE AIR (INTAKE): 72 CFM TOTAL EXAUST AIR: 50 CFM +84 CFM - 50 CFM = 34 CFM BUILDING PRESSURE: POSITIVE EXIST 4" THRU W) REVISIONS Q2/9/16 AS BUILT IDEAS DESIGNS ARRANGEMENTS AND PLANS :CATED OR REPRESENTED BY THIS DRAWING OWNED AND COPYWRITED BY, AND THE PERTY OF THIS OFFICE AND WERE CREATED, (LVED AND DEVELOPED FOR USE ON, AND CONNECTION WITH, THE SPECIFIED PROJECT. E OF SUCH IDEAS, DESIGNS, ARRANGEMENTS PLANS SHALL BE USED BY OR DISCLOSED ANY PERSON, FIRM OR ENTITY FOR ANY POSE WHATSOEVER WITHOUT WRITTEN MISSION OF JOEL S. SCHULTZ ARCHITECT TTEN DIMENSIONS SHALL HAVE PRECEDENCE :R SCALED DIMENSIONS. CONTRACTOR SHALL tIFY AND BE RESPONSIBLE FOR THE OFICATION OF ACTUAL JOB CONDITIONS, SHALL REPORT DISCREPANCIES TO ARCHITECT PRIOR TO COMMENCEMENT CONSTRUCTION. 2015 Ad e� ne c h u, t architect -ARCHITECTURE- 13072 ISABELLA TERRACE DELRAY B334 6 FLORIDA PH 954-895-2034 VANILLA BOX AT OCEAN PALM PLAZA UNIT 9 1600 N. FEDERAL HWY, BOYNTON BEACH FLORIDA e, A JOEL SI`ENCAROOD�70HITECT ICO 7 DATES DRAWN BY, J.S.S SCALE: AS NOTED PROJECT NO. SHEET NO. TOTAL M-1