Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
DRAWINGS
FIR E A LA OR M FL SCALE: 118 i NORTH KEY PLAN- NOT TO SCALE CPA '_ rIsk WIRELESS DIALERS If any document prepared by Fire Control Inc. are altered in any manner by owner, its agents or by any third party if construction is not in accordance with unaltered documents prepared by Fire Controls Inc. then it is understood that Fire Controls Inc. has no liability in whole or in part, related to the project and that the owner and its agents indemnify and holds harmless Fire Controls Inc. for any and all acts related to the project. This concept drawings are for information only to potential system arrangement. Contractor shall field verify all information contained on these drawings and is responsible for design and installation of the system in accordance with the specs. To the best of our knowledge the drawings and specifications submitted herewith, comply with existing interpretations and previsions of the applicable N.F.P.A. codes in effect at the date shown below. No warranty express or implied is hereby given. DATE` 01/18/2016 SCALE: As Noted *k�dN' Co cz Cz .O m LL U_ C �cl)�°?m �cz�� CZ aCio� U`zT�`` ' R T v co LICENSED ENGINEER: C/A #9650 ROBERT WEINSTEIN, P.E. 428 S. DIXIE HIGHWAY HOLLYWOOD, FL 33020 954-240-1917 FL. LIC. J 38036 38036 lb WCO s DRAWN 8Y: 11111111 %6kECKED BY- I L REVISION: REVISION: REVISION: SHEET TITLE Fire Alarm Floor Plan SHEET N0. FA1 OF 4 1) The fire alarm system is U.L. Listed as POWER LIMITED & of the general alarm type per NEPA 72, 2010 edition. All equipment is compatible and Listed for its intended use. 2) The fire alarm panel is provided with standby battery per NFPA 72 4.4.1.5.3.1 with 24 hours standby and 5 minutes alarm. Should loss of normal 120VAC operating power occur, the fire alarm panel will automatically transfer to the standby battery. 3) A break in any field wiring or grounding of any conductor will result in the activation of the fire alarm panel trouble buzzer, which can be silenced by operating the "Trouble Silence" button on the fire alarm panel. 4) Pull stations to be mounted at 48" AFF per the ADA code. 5) Detectors shall not be located in a direct airflow or closer than 1 m (3 ft) from an air supply diffuser or return air opening. NFPA 72 A.5.7.4.1 (2010) 6) Power up and power down of the fire alarm panel must be done in the proper sequence: Power Down: Disconnect battery and then turn off the AC power at the breaker. Power Up: Turn on the AC power at the breaker and then connect the battery. NOTE: Do NOT disconnect the AC power feed from the terminal block to disconnect power. 7) The 120VAC power feed for the fire panel and booster power supplies must be from a dedicated breaker, and the breaker must be identified as "FIRE ALARM CIRCUIT". 8) The control (relay) module for AHU shutdown shall be located within three (3) feet of the device being controlled. NFPA 101 A-7-6.5.5 (2009) The control module shall be located such that the front mounted LED is visible upon entry into mechanical room. The relay contacts have a MAXIMUM capability of 1.0 amps @ 24v and 0.3 amps © 120VAC. Contractor must verify that the shutdown circuit does NOT exceed these maximum current ratings. 9) The Installing Contractor Shall set the Device Address as identified on the Floor Plan and Riser Page (s). 10) Wall Mounted Horns and strobes to be at 80" to bottom or 6" from ceiling which ever is lower. 11) Notification Appliance Circuit Shall be "Class B — Style Y" 12) Signaling line Circuits (SLC) Shall be "Class B — Style 4" 13) ALL DEVICES ARE COMPATIBLE 14) All duct detectors will send a supervisory signal to fire alarm panel. 15) Conduit shall not exceed 40% of conduit capacity. 16) Maximum number of devices on slc circuit is 198 devices 17) All audible devices shall be 3 PULSE temporal. 18) All strobe lights shall be synchronized. 80" A.F.F. OR 6" BELOW CEILING (WHICHEVER IS LOWER) STROBE OR HORN/STROI PULL STATION 48" A.F.F. ADA HEIGHT REQUIREMENTS - NO SCALE U-91011 W11111 N 1) SUPPLY AND INSTALL NEW N❑TIFICATI❑N AND INITIATING DEVICES PER FLOOR PLAN, 2) SYSTEM TO BE TESTED WITH FIRE DEPARTMENT ON COMPLETION. DEVICE LEGEND FACP NOTIFIER AFP -200 ANALOG FIRE PANEL © NOTIFIER NBG-12LX MANUAL PULL STATION (Z)P NOTIFIER FSP -851 PHOTO SMOKE SENSOR L7RR AIR PRODUCTS AND CONTROLS PAM RELAY [kfll SYSTEM SENSOR RTS -151 �0P NOTIFIER DNR DUCT DETECTOR W/ FSP -851 LTJ SYSTEM SENSOR P2R MULTI -CANDELA SERIES HORN/STROBE e0; SYSTEM SENSOR SR MULTI -CANDELA SERIES STROBE 6 SYSTEM SENSOR PC2R MULTI -CANDELA SERIES HORN/STROBE @O SYSTEM SENSOR SCR MULTI -CANDELA SERIES STROBE 3/4" FLEX 4" SQUARE (2-1/8" DEEP) BOX 4" SQUARE, 2-1/8" DEEP BOX (OR 4-0 BOX). PROVIDE ADEQUATE ff4]D SUPPORT FOR BOX IN CEILING. CEILING ,e 4" SQUARE BOX TO 3-0 ADAPTER RING (OR NO RING IF 4-0 BOX IS USED) I PLUG-IN DETECTOR BASE DETECTOR HEAD BOX MOUNTING IN LIFT OUT OR INTERLOCKING TYPE CEILINGS WHEN SYSTEMS INSTALLED IN CONDUIT RACEWAY 2 Hour Fire Rated Through G`osslf/ems Penetration Firestop for CAJ1047 © Multiple Metal Pipe through (326) Concrete floors or walls S• using FYRE-SHIELD. YstaR` Drawing not to scale F -rating = 2 Hr. T -rating = 0 Hr. 2 1 3B 36 2 1Q Floor or Wall assembly = 4 " thick concrete, Max. area of opening is 288 sq. in. ® -Copper Pipe: 4" dia. (or smaller) regular (or heavier) copper. -Steel Pipe: 8" dia. (or smaller) Sch.40 (or heavier) steel. -Conduit: 4" dia. (or smaller) EMT or 6" dia. (or smaller) steel conduit. -Copper Tubing: 4" dia.(or smaller) Type L(or heavier) copper. -Iron Pipe: 8" dia.(or smaller) cast or ductile iron. -Max. number of pipes with opening is three (3). ® A) Forming Material - (Not shown) - Nom. 1" thick poly- urethane backer rod friction fitted into opening. B) Nom. 36" FYRE-SHIELD thickness installed within opening. NOTE: For wall apply FYRE-SHIELD to both surfaces of wall. WIRING FOR ADB -FL BASE (STYLE 4) DETECTOR BASE. THIS DIAGRAM IS FOR REPRESENTATIVE PURPOSES ONLY, AND IS NOT AN EXACT SPECIFICATION. SEQUENCE OF OPERATION 1.) THE FIRST ACTIVATION OF ANY MANUAL FIRE ALARM PULL STATION, OR THE AUTOMATIC ACTUATION OF ANY THERMAL DETECTOR, SMOKE DETECTOR, WATERFLOW SWITCH OR ANY OTHER APPROVED ALARM INITIATING DEVICE SHALL IMMEDIATELY RESULT IN THE FOLLOWING: A. NOTIFY THE UL LISTED CENTRAL STATION. B. ACTIVATE ALL AUDIBLE/VISUAL EVACUATION/INDICATING APPLIANCES C. IF AUDIBLE APPLIANCES ARE SILENCED, VISUAL APPLIANCES SHALL STOP FLASHING NFPA-72.4.4.3.7.2 2007 EDITION. D. ALL AUDIBLE ALARM INDICATING APPLIANCES SHALL SOUND ALARM THROUGHOUT THE BUILDING UNTIL SILENCED AT THE FIRE ALARM CONTROL PANEL. E. WATERFLOW ALARMS SHALL NOT SILENCE ANY ALARM INDICATION APPLIANCE UNTIL WATERFLOW HAS CEASED. F. ANY SUBSEQUENT DEVICE ALARM SHALL REACTIVATE THE ALARM INDICATING APPLIANCES. G. THE SYSTEM ALARM LED SHALL FLASH ON THE DISPLAY UNIT. THE SYSTEM ALARM LED SHALL FLASH ON THE CONTROL PANEL UNTIL THE ALARM HAS BEEN ACKNOWLEDGED. ONCE ACKNOWLEDGED, THIS SAME LED SHALL LATCH ON. A SUBSEQUENT ALARM RECEIVED FROM ANOTHER DEVICE SHALL FLASH THE SYSTEM ALARM LED ON THE CONTROL PANEL. THE LED DISPLAY SHALL SHOW THE NEW ALARM INFORMATION. H. DISPLAY ALL ALARM/STATUS INFORMATION AT REMOTE ANNUNCIATOR. 2.) RECEIPT OF SPRINKLER WATERFLOW SIGNAL: A) FLOW BELL SHALL SOUND UPON ACTIVATION OF FLOW SWITCH ONLY. B) FLOW BELL SHALL SOUND AS LONG AS WATER IS FLOWING. C) FLOW BELL SHALL NOT BE CAPABLE OF BEING SILENCED FROM FACP. D) DISPLAY ALL ALARM/STATUS INFORMATION AT REMOTE ANNUNCIATOR. 3.) ACTIVATION OF SUPERVISORY CONDITION: A) ANNUNCIATION OF SUPERVISORY ALARM AT FACP. B) DEVICE ADDRESS AND SUPERVISORY ALARM CONDITION INDICATED AT FACP. C) SUPERVISORY SIGNAL 'TRANSMITTED TO LISTED CENTRAL STATION. D) DISPLAY ALL ALARM/STATUS INFORMATION AT REMOTE ANNUNCIATOR. 4.) ACTIVATION OF ANY TROUBLE CONDITION: A) TROUBLE SIGNAL TRANSMITTED TO LISTED CENTRAL STATION. B) ANNUNCIATION OF TROUBLE ALARM AT FACP. C) DEVICE ADDRESS AND TROUBLE ALARM CONDITION INDICATED AT FACP. D) DISPLAY ALL ALARM/STATUS INFORMATION AT REMOTE ANNUNCIATOR. If any document prepared by Fire Control Inc. are altered in any manner by owner, its agents or by any third party if construction is not in accordance with unaltered documents prepared by Fire Controls Inc. then it is understood that Fire Controls Inc. has no liability in whole or in part, related to the project and that the owner and its agents indemnify and holds harmless Fire Controls Inc. for any and all acts related to the project. This concept drawings are for information only to potential system arrangement. Contractor shall field verify all information contained on these drawings and is responsible for design and installation of the system in accordance with the specs. To the best of our knowledge the drawings and specifications submitted herewith, comply with existing interpretations and previsions of the applicable N.F.P.A. codes in effect at the date shown below. No warranty express or implied is hereby given. 01/18/2016 N.T.S NOTE 3 CABLE. NOTE 1: DETECTOR WIRING ((SLC LOOP)) TO BE @)_� C;) > tM INSTALLED USING TWISTED/SHIELDED c15 O=3 NOTE 3 CZ BOARD AT FROM INTFC31j. O TO NEXT DEVICE NOTE 2: DO NOT LOOP WIRE UNDER TERMINALS 1 &2. BREAK WIRE RUN TO PROVIDE FACP U°?WCZ "W (WHERE SUPERVISION W Cl) CZ C APPLICABLE) c 0 CZ NOTE 3: OBSERVE POLARITY. DO NOT GROUND NOTE M SHIELDS TOGETHER AT EACH DETECTOR. NOTE 4: SET THE ROTARY DIALS ON THE REAR OF THE DETECTOR HEAD TO CORRESPOND TO THE LAST TWO DIGITS OF THE DEVICE 2(+ 1(—) 300 2(+1(—) 300 LOOP ADDRESS. REFER TO THE FLOOR PLANS FOR THE DETECTOR DEVICE ❑ mi TYPE ❑ mi TYPE LOOP DRESS LOOP ADDRESS WIRING FOR ADB -FL BASE (STYLE 4) DETECTOR BASE. THIS DIAGRAM IS FOR REPRESENTATIVE PURPOSES ONLY, AND IS NOT AN EXACT SPECIFICATION. SEQUENCE OF OPERATION 1.) THE FIRST ACTIVATION OF ANY MANUAL FIRE ALARM PULL STATION, OR THE AUTOMATIC ACTUATION OF ANY THERMAL DETECTOR, SMOKE DETECTOR, WATERFLOW SWITCH OR ANY OTHER APPROVED ALARM INITIATING DEVICE SHALL IMMEDIATELY RESULT IN THE FOLLOWING: A. NOTIFY THE UL LISTED CENTRAL STATION. B. ACTIVATE ALL AUDIBLE/VISUAL EVACUATION/INDICATING APPLIANCES C. IF AUDIBLE APPLIANCES ARE SILENCED, VISUAL APPLIANCES SHALL STOP FLASHING NFPA-72.4.4.3.7.2 2007 EDITION. D. ALL AUDIBLE ALARM INDICATING APPLIANCES SHALL SOUND ALARM THROUGHOUT THE BUILDING UNTIL SILENCED AT THE FIRE ALARM CONTROL PANEL. E. WATERFLOW ALARMS SHALL NOT SILENCE ANY ALARM INDICATION APPLIANCE UNTIL WATERFLOW HAS CEASED. F. ANY SUBSEQUENT DEVICE ALARM SHALL REACTIVATE THE ALARM INDICATING APPLIANCES. G. THE SYSTEM ALARM LED SHALL FLASH ON THE DISPLAY UNIT. THE SYSTEM ALARM LED SHALL FLASH ON THE CONTROL PANEL UNTIL THE ALARM HAS BEEN ACKNOWLEDGED. ONCE ACKNOWLEDGED, THIS SAME LED SHALL LATCH ON. A SUBSEQUENT ALARM RECEIVED FROM ANOTHER DEVICE SHALL FLASH THE SYSTEM ALARM LED ON THE CONTROL PANEL. THE LED DISPLAY SHALL SHOW THE NEW ALARM INFORMATION. H. DISPLAY ALL ALARM/STATUS INFORMATION AT REMOTE ANNUNCIATOR. 2.) RECEIPT OF SPRINKLER WATERFLOW SIGNAL: A) FLOW BELL SHALL SOUND UPON ACTIVATION OF FLOW SWITCH ONLY. B) FLOW BELL SHALL SOUND AS LONG AS WATER IS FLOWING. C) FLOW BELL SHALL NOT BE CAPABLE OF BEING SILENCED FROM FACP. D) DISPLAY ALL ALARM/STATUS INFORMATION AT REMOTE ANNUNCIATOR. 3.) ACTIVATION OF SUPERVISORY CONDITION: A) ANNUNCIATION OF SUPERVISORY ALARM AT FACP. B) DEVICE ADDRESS AND SUPERVISORY ALARM CONDITION INDICATED AT FACP. C) SUPERVISORY SIGNAL 'TRANSMITTED TO LISTED CENTRAL STATION. D) DISPLAY ALL ALARM/STATUS INFORMATION AT REMOTE ANNUNCIATOR. 4.) ACTIVATION OF ANY TROUBLE CONDITION: A) TROUBLE SIGNAL TRANSMITTED TO LISTED CENTRAL STATION. B) ANNUNCIATION OF TROUBLE ALARM AT FACP. C) DEVICE ADDRESS AND TROUBLE ALARM CONDITION INDICATED AT FACP. D) DISPLAY ALL ALARM/STATUS INFORMATION AT REMOTE ANNUNCIATOR. If any document prepared by Fire Control Inc. are altered in any manner by owner, its agents or by any third party if construction is not in accordance with unaltered documents prepared by Fire Controls Inc. then it is understood that Fire Controls Inc. has no liability in whole or in part, related to the project and that the owner and its agents indemnify and holds harmless Fire Controls Inc. for any and all acts related to the project. This concept drawings are for information only to potential system arrangement. Contractor shall field verify all information contained on these drawings and is responsible for design and installation of the system in accordance with the specs. To the best of our knowledge the drawings and specifications submitted herewith, comply with existing interpretations and previsions of the applicable N.F.P.A. codes in effect at the date shown below. No warranty express or implied is hereby given. 01/18/2016 N.T.S LICENSED ENGINEER: C/A ,#9650 G_ ROBERT WEINSTEIN, P.E. 428 S DIXIE HIGHWAY HOLLYWOOD, FL 33020 954-240-1917 FL. UC. # 38036 R` �(k)� w€,(ql �Y#38036 SE ••.••• �, - Off: • 8036 • � DRAWN BY: CHECKED BY: I L REVISION: L� REVISION: SHEET TITLE Fire Alarm Notes SHEET NO. FA3 of 4 T @)_� C;) > tM c15 O=3 CZ O�LL O CZU U°?WCZ "W W Cl) CZ C oo c 0 CZ O M LICENSED ENGINEER: C/A ,#9650 G_ ROBERT WEINSTEIN, P.E. 428 S DIXIE HIGHWAY HOLLYWOOD, FL 33020 954-240-1917 FL. UC. # 38036 R` �(k)� w€,(ql �Y#38036 SE ••.••• �, - Off: • 8036 • � DRAWN BY: CHECKED BY: I L REVISION: L� REVISION: SHEET TITLE Fire Alarm Notes SHEET NO. FA3 of 4 2-2-1 2-2-2 2-2-3 2-2-4 2-2-5 2-2-6 2-2-7 75cd 75cd 75cd 75cd 75cd 75cd 75cd CIRCUIT #2 PS9 1.104 AMP 3AMP MAX) EXISTING POWER SUPPLY NEW WIRE LEGEND SYMBOL WIRE TYPE AND DESCRIPTION LABELED WIRE COLOR COLOR A 16-2 FPL WIRE FOR HORNS AND STROBES BROWN BROWN B 18-2 WIRE FPL FOR DATA COMMUNICATION RED RED C 18-2 FPL 24V POWER PANEL TRIP ORANGIEL ORAN(3E D 1#12 AWG THHN WIRE FOR GROUND CONNECTION GREEN GREEN E 2#12 AWG THHN WIRE FOR POWER SUPPLY AND CYAN AND PANEL TO 120 VOLT POWER NOTE: WIRE COLORS ARE FOR RISER REFERENCE ONLY, AND DO NOT REFLECT ACTUAL FIELD COLORS. CIRCUIT #1 PS9 EOL 1.259 AMP (3 AMP MAX) S8 T #1 PS8 >3 AMP �P MAX) low, JIM, , on roms Inc 'rsteel Brands/ offmovative solutions 2721 HN 19TH STREET PAND BEACH, FLORIDA 33069 (954)968-9111 (964)958-9933 FAX LIC 0 EF 200006563 ETL 100101197AYL-001 MM.FIRECONTROMMET CM I's Intertak WIRELESS DEALERS I If any document prepared by Fire Control Inc. are altered in any manner by owner, its agents or by any third party if construction is not in accordance with unaltered documents prepared by Fire Controls Inc. then it is understood that Fire Controls Inc. has no liability in whole or in part, related to the project and that the owner and its agents indemnify and holds harmless Fire Controls Inc. for any and all acts related to the project. This concept drawings are for information only to potential system arrangement. Contractor shall field verify all information contained on these drawings and is responsible for design and installation of the system in accordance with the specs. To the best of our knowledge the drawings and specifications submitted herewith, comply with existing interpretations and previsions of the applicable N.F.P.A. codes in effect at the date shown below. No warranty express or implied is hereby given. DATE: 01/18/2016 SCALE: N.T.S �(�C\1 � M C;) > CO CY) M CU Cz 0M 0 Li. W CZ Uv C/) Cz Cl) Cz c) cir) 0 Cz -I-- 4-07- C >% o 7- 0 M LICENSED ENGINEER: CIA X9650 H=YWO-OD S%VA�-- ROBERT WEIMSTEM, P.E. 428 S. DIXIE HIGHWAY HOLLYWOOD, FL 33020 954-240-1917 FL. LIC. 1 38036 ROBERT WFip"10JI111#036 4I Cs- • z 0A, DRAWN BY: I G G L REVISION: REVISION: REVISION: SHEET TITLE Fire Alarm Riser & Wire Legend SHEET NO. FA4 OF 4