DRAWINGS
SYSTEMS SYMBOL LEGEND SYMBOL DESCRIPTION Q AUTOMATIC TRANSFER SWITCH CALL BACK PUSH BUTTON EXISTING EQUIPMENT TO REMAIN aCIRCUIT GENERAL ELECTRICAL NOTES CR ELECTRICAL SYMBOL LEGEND SECURITY SYSTEM KEYPAD (GENERAL NOTES ARE PROVIDED AS A BASIC DESCRIPTION OF THE EXTENT AND QUALITY EXPECTED IN THIS PROJECT. IF A CONFLICT EXISTS ® CLOCK CL ❑Q BELL BETWEEN THESE GENERAL NOTES AND THE REMAINDER OF THE CONTRACT DOCUMENTS THE SPECIFICATIONS, PLANS AND DETAILS WILL GOVERN.) T.C. JACKS IN A SINGLE -GANG BOX MOUNTED AT 18" A.F.F. Q OAIR HANDLING UNIT SHUT -DOWN RELAY O SYMBOL DESCRIPTION AQ to 1. THE ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL 28. ALL CIRCUIT BREAKERS SHALL BE INVERSE TIME TYPE (THERMAL MAGNETIC OR SOLID TELEVISION SIGNAL WALL OUTLET (M.H. = 18" A.F.F.) WITH LIGHTING (REFER TO LIGHTINGFIXTURE SCHEDULE) CODE, 2008 EDITION (NEC), 2010 FLORIDA BLDG. CODE AND CURRENT (IN USE) STATE AS REQUIRED BY SPECIFICATION). TWO AND THREE POLE CIRCUIT BREAKERS COMPUTER/TELEPHONE OUTLET (2) 8 -CONDUCTOR RJ -45 JACKS IN SINGLE -GANG BOX. (18" A.F.F.) EDITIONS OF ALL LOCAL CODES, RULES AND ORDINANCES HAVING JURISDICTION. SHALL BE COMMON TRIP. NO TIE HANDLES PERMITTED. A LIGHT FIXTURE DESIGNATION. 2. AS A MINIMUM, ALL EQUIPMENT SHALL MEET APPLICABLE STANDARDS, FOR THE TYPE OF 29• ALL FUSES SHALL BE CURRENT LIMITING, PER U.L., RATED 60OV., UON. LIGHTING FIXTURE, SURFACE MOUNTED EQUIPMENT AND INTENDED USE, OF THE FOLLOWING: A. NON -TIME DELAY FUSES IN MAIN SWITCHES AND SWITCHES FEEDING PANELS. B. TIME DELAY FUSES FOR MOTOR AND A/C CIRCUITS. O LIGHTING FIXTURE (HID, FLUORESCENT OR INCANDESCENT), RECESSED MTD. A. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) B. ILLUMINATING ENGINEERS SOCIETY (IES) 30. ALL DISCONNECT SWITCHES SHALL BE SIZED BY NEC REQUIREMENTS TO ACCOMMODATE LIGHTING FIXTURE, WALL MOUNTED C. AMERICAN SOCIETY FOR TESTING ANDMATERIALS (ASTM) EQUIPMENT SERVED, INCLUDING REQUIRED FUSES U.O.N. SWITCHES SHALL BE D. NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATES.(NEMA) HORSEPOWER RATED FOR MAX. HORSEPOWER, HEAVY DUTY TYPE. EXIT LIGHT FIXTURE. DIRECTION ARROWS AS SHOWN E. NOTE: THESE STANDARDS ARE SUBORDINATE TO CODES AND STANDARDS SET BY U.L. 31. CONTRACTOR SHALL VERIFY CIRCUIT PROTECTIVE DEVICE RATING FOR EQUIPMENT PRIOR F0 WALL MOUNTED EXIT LIGHT FIXTURE ALL ELECTRICAL EQUIPMENT, DEVICES, WIRE, ETC., SHALL BE LISTED, FOR INTENDED TO INSTALLATION. (SHADED QUADRANT INDICATES FACE(S) OF FIXTURE) USE, WITH UNDERWRITER'S LABORATORIES INC. (U.L.), WHERE STANDARDS HAVE BEEN 32. FURNISH AND INSTALL DISCONNECT SWITCHES AND WIRING FOR AIR CONDITIONING® 2 X 2 FLUORESCENT LIGHT FIXTURE ESTABLISHED BY U.L. SYSTEM AS PER MANUFACTURER RECOMMENDATIONS. CONTROLS ARE TO BE SUPPLIED BY AIR CONDITIONING CONTRACTOR AND CONNECTED. PROVIDE ALL CONTROL WIRING FOR © 2 X 4 FLUORESCENT LIGHT FIXTURE 3. CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS AND SUPERVISION NECESSARY TO A/C SENSORING AND CONTROL UNITS, COORDINATE WITH A/C CONTRACTOR FOR WIRING ACCOMPLISH THE WORK AS SHOWN AND/OR NOTED ON THE DRAWINGS. DIAGRAMS AND EXACT MOUNTING LOCATIONS.® DIAGONAL SHADING DENOTES LIGHT FIXTURE CONNECTED TO 4. THE CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY ALL CONDITIONS, LOCATIONS, 33. ALL ELECTRICAL EQUIPMENT SHALL BE RAINTIGHT WHERE EXPOSED TO THE WEATHER. EMERGENCY BRANCH CIRCUIT OR, W/EMERG. BATTERY PACK. 1 X 4 FLUORESCENT LIGHT FIXTURE DIMENSIONS AND COUNTS AS SHOWN OR NOTED ON THE DRAWINGS, PRIOR TO ALL FLEX CONDUITS CONNECTED TO SUCH EQUIPMENT SHALL BE LIQUID TIGHT. ® DIAGONAL SHADING DENOTES LIGHT FIXTURE CONNECTED TO EMERGENCY SUBMITTING BID. 34. EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND NEMA RATED FOR THE BRANCH CIRCUIT OR, W/EMERG. BATTERY PACK. 5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL LABOR, ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED. FLUORESCENT WALL MOUNTED FIXTURE WITH WALL OUTLET BOX MATERIALS AND SUPERVISION NECESSARY TO ACCOMPLISH THE WORK AS SHOWN 35. ALL CONNECTIONS TO GROUND RODS SHALL BE MADE WITH U.L. APPROVED WELDED FLUORESCENT STRIP FIXTURE AND/OR NOTED ON THE PLANS. CONNECTIONS, UNLESS NOTED OTHERWISE. THE CONTRACTOR SHALL FORMA DIAGONAL SHADING DENOTES LIGHT FIXTURE CONNECTED TO EMERGENCY GROUNDING ELECTRODE SYSTEM AS PER NEC 250-50. 6. ELECTRICAL CONTRACTOR SHALL NOT SCALE DRAWINGS. CONTRACTOR SHALL REFER TO BRANCH CIRCUIT OR, W/EMERG. BATTERY PACK. ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT 36. OUTLET IN DRY LOCATIONS BOXES SHALL BE PRESSED STEEL, IN WET OR DAMP 0-0-0 EXTERIOR LIGHT FIXTURE WITH ARMS AS SHOWN ON DRAWINGS UNLESS NOTED OTHERWISE. LOCATIONS SHALL BE CAST ALLOY WEATHER -RESISTANT OUTLET WITH THREADED HUBS AND IN OTHER CLASSIFIED AREAS IT SHALL BE IN A SPECIAL ENCLOSURE. PROPER EMERGENCY BATTERY WALL PACK WITH TWIN HEADS 7. IT SHAD BE UNDERSTOOD THAT ALL WORK PERFORMED SHALL BE DONE BY A LICENSED PLASTER RINGS SHALL BE USED WITH OUTLET BOXES. PROPER COORDINATION BETWEEN TOGGLE SWITCH 120/277V. 20 AMP.,(M.H. = 4$" A.F.F.) CONTRACTOR AND IN A FIRST-CLASS WORKMANLIKE MANNER. SAID CONTRACTOR SHALL ELECTRICAL SUBCONTRACTOR AND GENERAL CONTRACTOR FOR PLASTER RING INITIATION MEET ALL REQUIREMENTS SET FORTH BY ANY LOCAL ORDINANCE AND GOVERNING WILL BE REQUIRED. NO "GOOF" RINGS SHALL BE ALLOWED. ALL OUTLET BOXES SHALL TOGGLETOGGLE SWITCH 120/277V. 20 AMP. ,(M.H. = 48" A.F.F.) , 3 -WAY AUTHORITIES. BE SECURELY FASTENED. $4 TOGGLE SWITCH 120/277V. 20 AMP., (M.H. = 48" A.F.F.), 4 -WAY 8. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST 37. WHEN ELECTRICAL BOXES ARE LOCATED IN VERTICAL FIRE RESISTIVE ASSEMBLIES, PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. (CLASSIFIED AS FIRE/SMOKE AND SMOKE PARTITIONS), THEY SHALL BE INSTALLED TOGGLE SWITCH 120/277V. 20 AMP. KEYSWITCH, (M.H. = 48" A.F.F.) 9. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS WITHOUT AFFECTING THE FIRE CLASSIFICATION. ALL OF THE FOLLOWING CONDITIONS K FOR A PERIOD OF NOT LESS THAN ONE YEAR FROM DATE OF ACCEPTANCE, UNLESS SHALL BE MET: $F FAN SWITCH 120/277V. 20 AMP, (HORSEPOWER RATED) INDICATED OR SPECIFIED OTHERWISE. A. ALL ELECTRICAL BOXES SHALL BE METALLIC. Q� SPT 30 -MINUTE ROTATABLE TIMER SWITCH (M.H. = 48" A.F.F.) 10. IT SHALL NOT BE THE INTENT OF THESE PLANS AND/OR SPECIFICATIONS TO SHOW B. BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF FRAMING SPACE. C. BOX OPENING SHALL NOT EXCEED 10322.56 SQUARE MM (16SQUARE INCHES). �P TOGGLE SWITCH 120/277V. 20 AMP., WITH PILOT LIGHT, EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR SHALL BE EXPECTED TO D. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHALL BE {M.H.=48"A.F.F.) FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE FOR ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER COMPLETELY FILLED WITH JOINT COMPOUND (OR OTHER APPROVED MATERIAL). $TOGGLE SWITCH 120/277V. 20 AMP. EXPLOSION -PROOF, WORKING ORDER. E. PROVIDE A WALL AROUND OUTLETS LARGER THAT 10322.56 SQUARE MM (16 EX (M.H.=48"A.F.F.) SQUARE INCHES). THE INTEGRITY OF THE WALL RATING SHALL BE MAINTAINED. SPEED SWITCH 120/277V. 20 AMP. U.O.N. ,(M.H. = 48" A.F.F.) 11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING TO ORIGINAL CONDITIONS, F. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 64516 S ANY AND ALL DAMAGES TO BUILDING SURFACES, EQUIPMENT, ETC. CAUSED DURING THE SQUARE MM (100 SQUARE INCHES) PER 9.29 SQUARE METERS (100 SQUARE FEET). �N SINGLE PHASE MANUAL MOTOR STARTER, (M.H.=48" A.F.F.) PERFORMANCE OF WORK. G. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE RESISTIVE ASSEMBLIES SHALL DIMMER SWITCH 120/277V. 20 AMP., (M.H.=48" A.F.F.) (1500 WATTS 12. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE OR BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 609.6MM (24 INCHES). UNLESS OTHERWISE INDICATED) DELAYS AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE H. OUTLET BOXES SHALL BE SECURELY FASTENED TO WALL FRAMING MEMBERS. THREE-WAY DIMMER SWITCH (4$" A.F.F.) INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 1. THE OPENING IN THE GYPSUM BOARD FACING SHALL BE CUT NOT TO EXCEED 13. FOR ELECTRIC POWER SYSTEM, COORDINATE POWER SERVICE WITH POWER COMPANY; 3.175MM (1/8 INCH) BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF SINGLE POLE SWITCH (48" A.F.F.) (SUBSCRIPT INDICATES ITEM A. VERIFY LOCATION OF POWER SERVICE TERMINATION WITH POWER COMPANY, PRIOR THE OPENING. ° CONTROLLED) TO SUBMITTING BIO. CONTRACTOR TO VERIFY AVAILABLE SERVICE VOLTAGE AND PHASES 38. SMOKE DETECTORS SHALL BE PROVIDED NO CLOSER THAN 36" FROM SUPPLY AIR © PANIC SWITCH, MUSHROOM TYPE, (M.H.=48" A.F.F.) WITH POWER COMPANY PRIOR TO BID AND PROVIDE BID ALLOWANCE FOR ALTERNATES. DIFFUSERS. (P WALL MOUNTED - OCCUPANCY SENSOR SWITCH,(M.H.=48"A.F.F.) MFGR./MODEL B. PROVIDE TEMPORARY ELECTRICAL SERVICE FOR USE BY ALL TRADES DURING a�b CONSTRUCTION AND REMOVE SAME AT COMPLETION OF PROJECT, 39. CONTRACTOR SHALL PROVIDE A TYPE WRITTEN DIRECTORY OF EACH PANELBOARD. HAND SENSOR SWITCH/#WSD-PDT WRITTEN DIRECTORY IS NOT ACCEPTABLE, EXCEPT SPARE AND SPACES SHALL BE (a, b) OR (2) INDICATES TWO POLE SWITCH - WSD-PDT-2P 14. CONTRACTOR SHALL KEEP ALL AREAS IN WHICH WORK IS BEING PERFORMED, FREE HANDWRITTEN IN PENCIL. LV INDICATES LOW VOLTAGE - WSD-PDT-LV FROM DEBRIS AT ALL TIMES AND SAID AREAS SHALL BE LEFT BROOM CLEAN AT THE 40. PROVIDE A 4" STEEL REINFORCED CONCRETE HOUSEKEEPING PAD UNDER ALL FLOOR CEILING MOUNTED OCCUPANCY SENSOR - LIGHTING CIRCUIT CONTROLLER. END OF EACH WORKING DAY. MOUNTED ELECTRICAL EQUIPMENT. OS MFGR./MODEL# (SENSOR SWITCH/#CM-PDT) 15. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS, AND TESTING COSTS. 41. A. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE WITH OSE CEILING MOUNTED DUAL TECHNOLOGY EXTENDED RANGE OCCUPANCY 16. COORDINATE ALL ELECTRICAL SITE WORK WITH ALL OTHER TRADES CONTRACTORS. NEC 110.26 SENSOR - LIGHTING CIRCUIT CONTROLLER. SENSOR SWITCH/#CM-PDT-10. B. THE EXCLUSIVELY DEDICATED SPACE EXTENDING FROM FLOOR TO STRUCTURAL OS WALL MOUNTED - OCCUPANCY SENSOR (M.H.=96"A.F.F.) 17. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR FOR THE: ADVANCE CEILING WITH A WIDTH AND DEPTH OF THE PANELBOARD OR SWITCHBOARD MUST BE MFGR. MODEL WV -PDT # ORDERING OF LONG LEAD ITEMS, AS TO NOT INTERFERE WITH THE PRODUCTION OF CLEAR OF ALL PIPING, DUCTS, EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENT OR OTHER TRADES RESULTING IN ANY DOWN OR LAG TIME. THE CONTRACTOR SHALL NOT ARCHITECTURAL APPURTENANCES IN ACCORDANCE WITH NEC 40$. PP POWER PACK ORDER ANY ITEMS UNTIL APPROVED SHOP DRAWINGS ARE RETURNED TO HIM. 42. METER CANS, HUBS, & LUGS FOR SAME ARE TO BE FURNISHED & INSTALLED BY 18. ELECTRICAL CONTRACTOR SHALL SUBMIT (6 COPIES) EQUIPMENT LAYOUT OF ALL CONTRACTOR. CONTRACTOR TO VERIFY SPECIFIC TYPE OF METER CAN TO BE USED OCCUPANCY SENSOR NOTE: ELECTRICAL SPACES, ROOMS, ETC., TO ENGINEER FOR APPROVAL PRIOR TO ORDERING WITH F.P.L. PRIOR TO BID. CONTRACTOR SHALL PROVIDE ALL SWITCHPACKS AND CONDUCTORS AS EQUIPMENT OR INSTALLING CONDUITS, ETC. LAYOUT SHALL CONSIST OF PLAN VIEWS REQUIRED FOR LAYOUTS AND CONTROLS SHOWN ON PLANS. (SCALED AS REQUIRED) AND ELEVATIONS (DIMENSIONED) FOR EACH SUCH SPACE, 43. A. PROVIDE A PERMANENT SIGN ON THE MAIN ELECTRICAL ROOM DOOR TO THE BLDG. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ROOM, ETC. STATING THAT THE SERVICE DISCONNECTS ARE LOCATED INSIDE. 19. CONTRACTOR SHALL SUBMIT AT ONE TIME, SIX (6) SETS OF LOOSE-LEAF BOUND B. SIGNS SHALL BE PLACED AT THE MAIN DISCONNECT EQUIPMENT INDICATING TYPE AND AND INSTALL A COMPLETE AND FULLY FUNCTIONAL LIGHTING CONTROL BOOKS, INDEXED WITH ALL PRODUCTS, MATERIALS, LIGHTING FIXTURES, LAMPS, WIRING LOCATION OF ON-SITE EMERGENCY POWER SOURCES. WITH PLANS, AI INTENT OF THE SYSTEM IN ACCORDANCE THE LA S, OET LS, E DEVICES, SWITCHGEAR, ETC. CLEARLY HIGHLIGHTING ALL EQUIPMENT QUANTITIES AND ' _ 44. THE EQUIPMENT GROUNDING TERMINAL BARS OF THE NORMAL AND EMERGENCY DESIGN AND SPECIFICATIONS SHOWN ON THESE PLANS. DETAILS. ALL EQUIPMENT SHALL BE AS SPECIFIED ON PLANS: THE RESPONSIBILITY TO ELECTRICAL-Sr-ST,EM„PANELBOARDS SERVING THE, SAME,.13UIMNG SHALL BE BONDED ,. BASIC MATERIALS r ACCEPT OR REJECT ANY PROPOSED SUBSTITUTION REMAINS WITH THE PROJECT TOGETHER WITH AN 1N5ULA1EiY: CONiIt1UJ >C I _tR CONDUCTOR fi[fIT.Si4iAfiU.1:#2 T AFf`. DEVICE, ENGINEER. THE CONTRACTOR MAY AT HIS JUDGMENT USE ANY ARTICLE. NUMBER 6. PRODUCT, OR MATERIAL WHICH IN THE JUDGMENT OF THE ENGINEER EXPRESSED IN WRITING ARE EQUAL TO THAT SPECIFIED. 45. THE ELECTRICAL CONTRACTOR SHALL FURNISH A COMPLETE SET OF AS -BUILT DUPLEX RECEPTACLE, 20 AMP., 125V., (M.H.=187A.F.F.) DRAWINGS, SHOWING ALL CHANGES AND DEVIATIONS TO THE ARCHITECT/ENGINEER PRIOR ® FLOOR OUTLET BOX AND DUPLEX RECEPTACLE 20 AMP., 125V., WITH 20. ALL CONDUCTORS SHALL BE COPPER, TYPE THHN/THWN EXCEPT WHERE OTHERWISE TO COMPLETION OF THE PROJECT. APPROPRIATE FLANGE. REQUIRED BY U.L. OR CODES. MINIMUM WIRE SIZE SHALL BE #12 AWG, EXCLUDING CONTROL WIRING. ALUMINUM CONDUCTORS ARE NOT PERMITTED. 46. ARCHITECTURAL AND/OR ENGINEERING EXPENSES THAT ARE INCURRED DUE TO CEILING OUTLET BOX AND DUPLEX- RECEPTACLE 20A, 125V. REVISIONS OR SUBSTITUTIONS REQUESTED BY THE CONTRACTOR SHALL BE PAID FOR BY 21. ALL CONDUCTORS SHALL BE IN CONDUITS. ALL CONDUITS SHALL BE GALVANIZED RIGID THAT CONTRACTOR. STEEL (GRS) EXCEPT THAT: (a) PVC CONDUITS MAY BE USED UNDERGROUND' PROVIDED ELBOWS AND RISERS ARE GALVANIZED RIGID STEEL OR SCHEDULE 80 PVC, WHERE 47. FOR TELEPHONE SYSTEMS: /j'1 DUPLEXTOP HALF SWITCHED, M.H. _ SUBJECT TO PHYSICAL DAMAGE (b) ELECTRICAL METALLIC TUBING (EMT) MAY BE USED A. PROVIDE GROUNDING FOR ALL TELEPHONE OUTLETS AND EQUIPMENT PER A.F.F. UNLESS OTHERWISE NOTED IN OR ON WALLS OR CEILINGS WHERE NOT SUBJECT TO MECHANICAL DAMAGE, DAMP OR REQUIREMENTS OF THE TELEPHONE COMPANY. CORROSIVE CONDITIONS, (c) LIQUID TIGHT FLEXIBLE CONDUIT WHERE REQUIRED, (d) B. COORDINATE INSTALLATION OF ALL TELEPHONE OUTLETS, RACEWAYS, ENCLOSURES DUPLEX RECEPTACLE, 20 AMP., 125V., ISOLATED GROUND AND SURGE FLEXIBLE METALLIC CONDUIT WHERE REQUIRED IN DRY LOCATIONS ONLY, (e) MC CABLE AND BACKBOARDS WITH TELE. CO. C. VERIFY LOCATION OF TELEPHONE SERVICE WITH TELEPHONE COMPANY. PROVIDE PROTECTED, (M.H.=18"A.F.F.) WITH DEDICATED GREEN GROUNDING CONDUCTOR WHERE PERMITTED. ALL CONDUITS IN SERVICE CONDUIT TO BLDG. FROM SERVICE POINT PER TELCO. INSTRUCTIONS, INCLUDE (j} SINGLE RECEPTACLE, 20 AMP., 125V., COORDINATE M.H. WITH HAZARDOUS AREAS {PER NEC) SHALL MEET THE REQUIREMENTS OF NEC CHAPTER 5. ALL ASSOCIATED COSTS IN BID. ''11'' EQUIPMENT. 22. FOR UNDERGROUND ELECTRICAL CONDUITS, PROVIDE PULL BOXES, SUCH THAT NO D. MARK TERMINATIONS OF TELEPHONE CONDUIT AS DIRECTED BY THE TELEPHONE SINGLE CONDUIT RUN HAS BENDS IN EXCESS OF 360. PULL BOXES SHALL BE COMPANY.((��'�� SIMPLEX RECEPTACLE (16" A.F.F.) (EWC DENOTES ELECTRIC WATER SUITABLE AND APPROVED FOR THE INTENDED USE. WARNING TAPE WHICH SAYS E. VERIFY LOCATION OF TELEPHONE SERVICE WITH TELEPHONE COMPANY PRIOR TO `j'EWC COOLER. COORDINATE WITH EWC INSTALLER FOR MOUNTING HEIGHT) "WARNING BURIED ELECTRIC" SHALL BE PLACED IN TRENCHES ABOVE ALL UNDERGROUND SUBMITTING BID, INCLUDE ALL ASSOCIATED COSTS IN BID. ELECTRIC CONDUITS. WHERE CONDUITS PASS UNDERNEATH PAVED AREAS, THEY SHALL F. USE EXTERIOR GRADE 3/4" PLYWOOD BACKBOARDS FOR MOUNTING TELEPHONE TWO DUPLEX RECEPTACLES WITH COMMON COVER 20A., 125V.,(18" BE PVC. WHERE UNDERGROUND CONDUITS ARE NOT EXPOSED TO MECHANICAL DAMAGE EQUIPMENT AND TERMINAL STRIPS. PAINT BOARD ON ALL SIDES AND EDGES WITH TWO A.F.F.) OR ARE NOT UNDER PAVED AREAS, THEY SHALL BE SCHEDULE 40 PVC. COATS OF FLAT BLACK FIRE RETARDANT PAINT. 23. ALL CONDUIT RUNS ARE SHOWN DIAGRAMMATIC. EXACT ROUTING SHALL BE DETERMINED 48. INDUSTRIAL CONTROL TYPE TRANSFORMERS SHALL BE PROVIDED WITH FINGERSAFE ® SPECIAL PURPOSE OUTLET e.g. RANGE OUTLET, COORD. W/ EQUIPT. IN THE FIELD, UNLESS OTHERWISE NOTED. COVERS AND PRIMARY FUSE PROTECTION AS REQUIRED PER NEC 450-3. MOUNT I 24. WIREWAYS SHALL BE SIZED AS REQUIRED, PER NEC, UNLESS OTHERWISE NOTED (LION). TRANSFORMERS ON 4"X4" JUNCTION BOX ABOVE ACCESSIBLE CEILINGS OR ELECTRICAL DUPLEX RECEPTACLE, 20 AMP., 125V., MOUNT ABOVE COUNTER 042"AFF. ROOMS. 25. WHERE CORE DRILLING OF FLOOR/WALLS IS REQUIRED, CONTRACTOR SHALL SEAL 49. FOR RESIDENTIAL WORK PROVIDE COMBINATION TYPE ARC -FAULT CIRCUIT INTERRUPTER OPENINGS WATERTIGHT AFTER UTILITIES HAVE BEEN INSTALLED. LOCATION OF CORED PROTECTION THROUGHOUT THE DWELLING UNIT, EXCEPT IN KITCHEN BATHROOM, GARAGES 1p GFCI DUPLEX RECEPTACLE, 20 AMP., 125V., (M.H.=18"A.F.F.) HOLES SHALL COORDINATE WITH LOCATION OF EQUIPMENT IN A MANNER TO BE CLEAN AND FUNCTIONAL. THE CONTRACTOR SHALL INSTALL ONLY ONE CONDUIT PER HOLE AND AND OUTDOORS. ALL DWELLING UNIT RECEPTACLE OUTLETS MUST BE LISTED GFCI DUPLEX RECEPTACLE, 20 AMP., 125V., MTD. ABOVE COUNTER (VERIFY SEAL THE OPENING AROUND THE CONDUIT AS SPECIFIED. TAMPER-RESISTANT. "BACK HEIGHT) 50. PROVIDE U.L. LISTED COMPOUND APPLIED TO BACK OF TO BACK" BOXES IN 26. PROVIDE FIRE RETARDANT U.L. APPROVED SEALANT ON ALL PENETRATIONS OF FIRE RATED WALLS WHERE THE BOXES ARE LESS THAN 609.6MM (24 INCHES) APART i� 30 AMP., 125V., TWIST LOCK RECEPTACLE FOR FLOOR POLISHING MACHINE RATED PARTITIONS, WALLS AND STRUCTURAL SLABS. CONTRACTOR TO VERIFY, PRIOR TO MEASURED HORIZONTALLY. SUBMITTING BID, LOCATIONS OF ALL SUCH FIRE RATED PARTITIONS, WALL AND O JUNCTION BOX, MOUNTING AS SHOWN STRUCTURAL SLABS. 51. CONTRACTOR SHALL PROVIDE TYPED, UPDATED PANEL DIRECTORIES ON ALL PANELS THAT ARE AFFECTED AT THE COMPLETION OF THE JOB. IU POWER POLE 27. UNLESS NOTED AS EXISTING, ALL EQUIPMENT, WIRING, DEVICES, ETC. SHALL BE NEW. 52. FOR RECEPTACLES IN DAMP AND WET LOCATIONS THE CONTRACTOR SHALL PROVIDE ALL 125V. AND 250V., 15A. AND 20A. RECEPTACLES THAT ARE LISTED AS WEATHER RESISTANT A& ELECTRIC MOTOR, NUMBER INDICATES HORSEPOWER TYPE TO COMPLY WITH NEC ARTICLE 406.8. IVII K7U MAGNETIC MOTOR STARTER OR CONTACTOR, COMBINATION MAGNETIC MOTOR STARTER, SIZE AS NOTED GENERAL L I G HT1 N G NOTES: DISCONNECT SWITCH, SIZE AS NOTED # OF POLES ENCLOSURE TYPE: 1. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF LIGHT 13. FOR EMERGENCY EXIT SIGNS AND EMERGENCY BATTERY PACKS MAKE CONNECTION AMP RATING/FRAME NEMA 3R- FOR EXTERIOR FIXTURES. AHEAD OF ALL SWITCHES AND CONTROLS. 3100 NEMA 1- FOR INTERIOR 2. COORDINATE TYPE OF CEILING FOR EACH FIXTURE WITH ARCHITECTURAL REFLECTED 14. PROVIDE A FUSE HOLDER AND FUSE (BUSSMAN HEB AND FNQ OR EQUAL), IN THE CEILING PLANS AND PROVIDE FIXTURE TRIM AS REQUIRED. PRIMARY SIDE OF EACH UNGROUNDED CONDUCTOR FOR ALL BALLASTS AT THE HAND FUSE SIZE (* DENOTES AS PER MANUFACTURER) 3. ALL COMPACT FLUORESCENT DOWNLIGHTS SHALL USE LAMPS WITH 3500K TEMPERATURE, HOLE OF EACH EXTERIOR POLE MOUNTED LIGHTING FIXTURE OR J -BOX FOR WALL OR LIGHTING CONTROL TIME CLOCK MINIMUM 10,000 HOUR LIFE, ELECTRONIC BALLAST, UNLESS OTHERWISE NOTED. GROUND MOUNTED FIXTURE. 4. PROVIDE APPROVED FIRE RATED ENCLOSURES FOR ALL LIGHT FIXTURES LOCATED IN 15. PROVIDE WIND LOAD RATED LIGHT POLES WITH 145 MPH MINIMUM WIND SPEED (ASCE PHOTOCELL, MOUNTED ON ROOF FACING NORTH FIRE RATED CEILINGS. 7), EXPOSURE C WITH IMPORTANCE FACTOR OF 1.0, AND PROVIDE PHOTOMETRICS WITH® SHUNT -TRIP BUTTON - FLUSH MOUNTED UNLESS OTHERWISE NOTED 5. FIXTURES IN AREAS WITHOUT CEILINGS, OR IN MECHANICAL AND ELECTRICAL ROOMS ALL FIXTURE SUBMITTALS. CONTRACTOR TO VERIFY VOLTAGES OF ALL LIGHT FIXTURES SHALL BE MOUNTED WITH 1 h"X1 kz"KINDORF CHANNEL SUPPORT SUSPENDED FROM PRIOR TO BIDDING. PLUG-IN STRIP WITH RECEPTACLES, 18" O.C. UNLESS OTHERWISE INDICATED ROOF STRUCTURE WITH THREAD RODS. FIXTURES SHALL BE MOUNTED 10'-0" A.F.F. 16. PHOTOMETRICS ARE BASED ON MANUFACTURER'S INFORMATION AND CATALOG NUMBERS. ® 6. ALL ACRYLIC LENSED FIXTURES SHALL HAVE A LENS THICKNESS OF .125 INCHES ALTERNATIVE MANUFACTURERS MUST PROVIDE THE IESNA FORMAT ELECTRONIC FILES OF MINIMUM. THE INDEPENDENT TEST LAB REPORTS FOR THE PROPOSED FIXTURES ON CD OR ® CABLE TRAY FLOPPY DISKETTE 10 WORKING DAYS PRIOR TO BID. (SPECIFIER) WILL CONFIRM THAT 7. HALF SHADED FIXTURES DENOTE EMERGENCY FIXTURES EITHER WITH 1100 LUMEN THE PHOTOMETRIC CRITERIA HAS BEEN MET, AND IF ALTERNATE IS APPROVED WILL i GROUND OR GROUND ROD AS NOTED EMERGENCY BATTERY PACK OR ON LIFE SAFETY CIRCUIT. ISSUE AN ADDENDUM. MANUFACTURERS NOT LISTED ON THE PLANS OR IN AN 8. LIGHTING FIXTURE SCHEDULE IS PREDICTED ON PERFORMANCE AND IS DESIGNED TO ADDENDUM WILL NOT BE ACCEPTED. -0 CONDUIT TURNING UP MEET CERTAIN AESTHETIC CRITERIA. ALL ALTERNATIVE SELECTIONS MUST BE SUBMITTED TO CONFIRM THAT THE SPECIFIED PHOTOMETRIC CRITERIA HAS BEEN MET, A COMPUTER CONDUIT TURNING DOWN FOR PRIOR APPROVAL TEN (10) DAYS PRIOR TO BID DATE. 17' DISK CONTAINING AN IES FILE FOR THE PROPOSED ALTERNATE MUST BE SUBMITTED TO CONDUIT STUB (SPECIFIER) FOR EVALUATION NO LESS THAT 10 DAYS PRIOR TO BID. ANY ACCEPTABLE 9. ALL BALLASTS SHALL HAVE MINIMUM POWER FACTOR OF 0.90. ALL BALLASTS FOR ALTERNATE MUST BE APPROVED IN WRITING PRIOR TO BID DATE. METAL HALIDE AND HIGH PRESSURE SODIUM FIXTURES SHALL BE CONSTANT WATTAGE CONTRACTOR MUST BID PROJECT USING SPECIFIED LIGHTING FIXTURES AS BASE BID (NO --Z CONDUIT CONTINUED TYPE WITH +/-5% LAMP WATTS FOR +/-10% NOMINAL UNE VOLTAGE VARIATION. 18. EXCEPTIONS). IF ALTERNATE FIXTURES ARE PROPOSED, THEY MUST BE BID AS AN 10. PROVIDE LAMPS WITH FIXTURES, VERIFY LAMP TYPE WITH MANUFACTURER. ALTERNATE BID MUST INCLUDE: 11. FLUORESCENT LUMINAIRES THAT UTILIZE DOUBLE -ENDED LAMPS AND CONTAIN A) TOTAL DOLLAR CREDIT TO OWNER IF ALTERNATE IS ACCEPTED. NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. BALLAST(S) OR MULTIWIRE BALASTED LUMINAIRES SHALL CONTAIN AN INTEGRATED B) LINE ITEM CREDIT FOR EACH ALTERNATE FIXTURE PROPOSED. INTERNAL DISCONNECT AND TO BE COMPLIED WITH NEC 410.73(G). C) CATALOG SUBMITTAL DATA FOR EACH ALTERNATE FIXTURE PROPOSED. 12. ALL OPENINGS FOR LIGHT FIXTURES IN CEILINGS SHALL BE PROTECTED IN A MANNER 19. IF THERE IS A DISCREPANCY BETWEEN A FIXTURE DESCRIPTION AND GENERAL NOTES, TO THE BEST OF THE ENGINEER'S KNOWLEDGE, THE PLANS AND SPECIFICATIONS (PER ALL GOVERNING CODES) THAT WILL PROVIDE THE SAME RATING AS THE- CEILING. AND THE CATALOG NUMBER LISTED, THE FIXTURE DESCRIPTION AND GENERAL NOTES COMPLY WITH THE APPLICABLE MINIMUM BLDG. CODES AND APPUCABLE FIRE -SAFETY (THIS APPLIES TO ALL FIRE RATED CEILINGS). SHALL GOVERN. STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN ACCORDANCE WITH SECTION 20. COORDINATE FIXTURE TYPES WITH ARCHITECTURAL DRAWINGS. 110.3.7.4.4 AND CHAPTER 633, FLORIDA STATUES. SYSTEMS SYMBOL LEGEND SYMBOL DESCRIPTION Q AUTOMATIC TRANSFER SWITCH CALL BACK PUSH BUTTON EXISTING EQUIPMENT TO REMAIN aCIRCUIT BREAKER, TYPE AND SIZE AS PER DRAWINGS. CR KP SECURITY SYSTEM KEYPAD �c ® CLOCK CL ❑Q BELL COMPUTER/TELEPHONE OUTLET WITH (2) 8 -CONDUCTOR RJ -45 T.C. JACKS IN A SINGLE -GANG BOX MOUNTED AT 18" A.F.F. Q OAIR HANDLING UNIT SHUT -DOWN RELAY O NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. POWER ON INDICATOR WITH KEYED RESET SERVICE AND DISTRIBUTION ELECTRICAL BRANCH CIRCUIT PANELBOARD, RECESS MOUNTED. (SEE PANEL SCHEDULE FOR DETAILS) ELECTRICAL BRANCH CIRCUIT PANELBOARD, SURFACE MOUNTED. (SEE PANEL SCHEDULE FOR DETAILS) aTRANSFORMER, SIZE AS NOTED A.F. AUTOMATIC TRANSFER SWITCH - - -- EXISTING EQUIPMENT TO REMAIN A.S.W. NEW EQUIPMENT OR WORK OF THIS PROJECT CR SECURITY SYSTEM CARD READER, SEE SPECS. TELEPHONE/COMPUTER RACEWAY SYSTEM SECURITY SYSTEM CABLES IN CONDUIT, SEE SPECS. ® TELEPHONE/COMPUTER TERMINAL BOARD "71`13" CL INTERCOM SYSTEM SPEAKER aSECURITY • COMPUTER/TELEPHONE OUTLET WITH (2) 8 -CONDUCTOR RJ -45 T.C. JACKS IN A SINGLE -GANG BOX MOUNTED AT 18" A.F.F. Q C = ABOVE THE COUNTER IG P = PUBLIC PAY (48" A.F.F.) NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. W = WALL MOUNTED (18" A.F.F.) AQ to DATA/TELEPHONE PORT - CEILING MOUNTED DATA/TELEPHONE PORT - FLOOR MOUNTED -- TELEVISION SIGNAL WALL OUTLET (M.H. = 18" A.F.F.) WITH 8 -CONDUCTOR RJ -45 JACK AND F -TYPE RG6 COAX JACK IN SINGLE -GANG BOX. TELEVISION SIGNAL WALL OUTLET F -TYPE RG6 COAX JACK & COMPUTER/TELEPHONE OUTLET (2) 8 -CONDUCTOR RJ -45 JACKS IN SINGLE -GANG BOX. (18" A.F.F.) A.C. SECURITY SYSTEM A.F. SECURITY SYSTEM CAMERA, PROVIDE POWER AND SIGNAL A.F.F. CONNECTION, SEE SPECS. A.S.W. SECURITY SYSTEM MONITORS AND RECORDERS, SEE SPECS. CR SECURITY SYSTEM CARD READER, SEE SPECS. B.F.G SECURITY SYSTEM CABLES IN CONDUIT, SEE SPECS. QS SECURITY SYSTEM JUNCTION BOX AT ACCESSIBLE LOCATION. CL SYSTEM HIDDEN PUSH BUTTON FOR DOOR STRIKE aSECURITY • RELEASE, COORDINATE INSTALLATION WITH FURNITURE OR T.C. EQUIPMENT. Q SECURITY SYSTEM SPEAKER WITH INTEGRAL MICROPHONE IG SECURITY SYSTEM KNOX BOX NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. DEVICE) ABBREVIATIONS A.C. ABOVE COUNTER A.F. ARG FAULT A.F.F. ABOVE FINISHED FLOOR A.S.W. ABOVE SHOW WINDOW RCPT. B.F.C. BELOW FINISHED CEILING B.F.G BELOW FINISHED GRADE C.B. CIRCUIT BREAKER CL CENTER LINE D DEDICATED FOR COMPUTER, T.C. PROVIDE DEDICATED GROUND T.S. AND NEUTRAL IG ISOLATED GROUND (ORANGE WP. DEVICE) EM PROVIDE EMERGENCY BATTERY PACK W/FIXTURE, CONNECT AHEAD OF ALL SWITCHES. EX EXISTING ER EXISTING RELOCATED G.F.I. GROUND FAULT INTERRUPTER L.C. LOCKABLE COVER M.H. MOUNTING HEIGHT N NEW DEVICE N.F. NON FUSED NL NIGHT LIGHT RE EXISTING TO BE REMOVED T.C. TERMINAL CABINET T.S. TIME SWITCH U.O.N. UNLESS OTHERWISE NOTED WP. WEATHER PROOF ENCLOSURE XFMR. TRANSFORMER. �( DETAIL E-X,XX SHEET NUMBER NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. ELECTRICAL INDEX _ .. RAWIN 1 E-1 ELECTRICAL INDEX, SYMBOL LEGEND AND NOTES. 2 E-2 SITE ELECTRICAL PLAN 3 E-3 PANEL SCHEDULE AND RISER SHOP DRAWING REQUIREMENTS 1. CONTRACTOR SHALL SUBMIT 6 COPIES OF COMPLETED SHOP DRAWINGS, TOGETHER AT ONE TIME AND MUST COME THROUGH THE ARCHITECT, ALL SUBMITTALS SHALL BE MADE WITHIN 30 DAYS OF NOTICE TO PROCEED. 2. ALL SUBMITTALS MUST CLEARLY INDICATE EXACTLY WHICH ITEMS ARE BEING PROPOSED FOR USE. IF NOT, THE SUBMITTAL SHALL BE REJECTED. 3• SUBSTITUTIONS SHALL BE LIMITED TO ONE OF THE ALTERNATES LISTED IN THE CONSTRUCTION DOCUMENTS. PRODUCTS CONSIDERED TO BE EQUAL SHALL BE REVIEWED AND ACCEPTED BY THE ENGINEER, ARCHITECT AND OWNER (10) DAYS PRIOR TO BID DATE. 4. THE CONTRACTOR ASSUMES ALL DESIGN RESPONSIBILITY AND ALL FINANCIAL RISKS FOR PROCEEDING PRIOR TO SHOP DRAWINGS PROCESSING, AND ON ANY ITEM OR WORK THAT IS AT VARIANCE TO THE CONSTRUCTION DOCUMENTS. 5. SHOP DRAWINGS AND SUBMITTALS FOR EACH ITEM SHALL BE REVIEWED NO MORE THAN TWICE. A THIRD SUBMITTAL ON AN ITEM MUST BE ACCOMPANIED BY A PURCHASE ORDER FROM THE CONTRACTOR OR IT SHALL BE REJECTED. 6. CIRCUMSTANCES NECESSITATING A REVISION TO THE PERMITTED DOCUMENTS NOT PROCESSED PRIOR TO INSTALLATION MAY NOT BE ACCEPTED. IF ACCEPTED IT MUST BE LEGIBLE, ACCURATE AND ACCOMPANIED BY A PURCHASE ORDER ORDER FROM THE CONTRACTOR. THE REVISION SHALL BE CHARGED TO THE CONTRACTOR AND DELIVERED TO HIM ON A C.O.D. BASIS. 7. SUBSTITUTIONS FROM THE BASE DESIGN OR VARIATIONS TO THE PERMITTED CONTRACT DOCUMENTS, WHETHER RESULTING FROM PROCESSED SHOP DRAWINGS OR NOT, THAT RESULT IN REQUIREMENTS IN LETTERS OF AUTHORIZATION AND/OR PERMIT CONTRACT DOCUMENT CHANGES MANDATED BY THE AUTHORITY HAVING JURISDICTION WILL NOT BE MADE BY THIS OFFICE UNLESS ACCOMPANIED BY A PURCHASE ORDER FROM THE CONTRACTOR, AND RELEASED ON A C.O.D. BASIS. 8. CONTRACTOR SHALL SUBMIT 5 COPIES OF EQUIPMENT LAYOUTS OF ALL ELECTRICAL SPACES, ROOMS, ETC. TO THE ENGINEER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT OR INSTALLING CONDUITS, ETC. THE LAYOUTS SHALL CONSIST OF PLAN VIEWS AT A SCALE OF 1/2" = 1'0" AND ELEVATIONS FOR EACH SUCH SPACE OR ROOM, ETC. Lp. I r _ Copyright 2011 Material shown here?s_[hp-Cnpyrigh+ed Oroperty of-)e'na r r Consulting Engineers. Inc. bnd-shal nut bu rehrocdred�r�whnle orn part withautaxpsr wr• ert pe�nisJior ` r DEIJA(.31 CON�JL�"1�VG ENGINEERS"', IA C. THE ENGINEERING SPECIALISTS REVISIONS: G PROJECT #: 150504 _ PROJECT MANAGER: S.B. ` C.B. C.A.#: 00009181 DATE: 05/1612016 � ° a ® fl �0 , e : , , ®/ PROJECT #: 150504 _ PROJECT MANAGER: S.B. DESIGNED BY: C.B. C.A.#: 00009181 DATE: 05/1612016 SEAL g F An `ase' ��✓� � ° a ® fl �0 , e : , , ®/ '1/011111WI, SHEET NO. E- I �ire GROUND FLOOR ELECTRICAL PLAN N +M E-2 SCALE: I"=10' -O" r --------- ------ EXISTING WORK TO REMAIN EXISTING TO BE REMOVED NEW WORK SCOPE OF WORK STATEMENT SCOPE OF WORK IS TO ADD TWO SPECIALTY OUTLETS ON EXTERIOR WALL IN TWO PARKING SPACES FOR ELECTRIC VEHICLE CHARGING. --- Copyright 2011 Material,simr,here Poperty,f Dclt&-G Consulftn, E4nee '-in-- a' cfs!al('iof?�-,.5pr(d6e� vn oL- 5r iC part W',no"! e�prErs r',rjt( m r'4rrrsSLn. I ME ENGINEERING SPECIALISTS Delta G Consulting Engineers, Inc. 707 N.E. 3rd Ave. Suite 200 Fort Lauderdale, FL 33304 (954) 527-1112 Tel. (954) 524-7505 Fax www.DeltaG.net REVISIONS: G __ PROJECT #: 160504 PROJECT MANAGER: S.B. DESIGNED BY: C.B. C.A.#: 00009181 DATE: 05/16/2016 (ZI-4I=PT Kin W� 0 PL (ZI-4I=PT Kin LOCATION- SEE FLOOR PLAN lS EA STING 0 NEW rVT I OAD OESCRIPTIOt HSCHEDULE o SETION 2 SPEC: G.E. A SERIES PANEL COPPER BUS O ALUMINUM BUS POLE/ KVA KVA KVA POLI F. GRD. q, i, TRIP A PHASE B PHASE C PHASE TP COND. GRD. WIRE LOAD DESCRIPTION CKT. 0 SPARE 44 YELT E E 20 1 2' 7 E 20 2 E = E E -- ROOM RECEP. & LIGHT 46 E E E 20 "� 0 8� _ 20; — — — SPARE 48 E E E E 20 1.0 01 20 ; E E E SHUNT TRIP 50 E E E E 20 U.1 1 20 E E E SHUNT TRIP 52 E 3 20- 1.8 5.9 3 6( E E E POOL EQUIPMENT PANEL 54 E E 1.8 59 ,. W 56 U 1.8 5.9 . ". 58 E 3 60 2.2 0.5 2 2G E E E WEST ELEV. MACH. RM. PTAC 60 E E 2.2 0 5 62 E-+ 05 22 ' 2 2G E E E EAST ELEV. MACH. RM. PTAC 64 E E E 20 0.8 ; , s 0.6 0.5 3.6 2 50 1 10 8 ICAR CHARGING OUTLET 66 68 E E E E E 20 E 20 0.6 3.6 3.6 2 501 10 8 CAR CHARGING OUTLET 70 72 36 74 — _ — — — SPACE 76 — — — — — — — — SPACE 78 SPACE 80 SPACE 82 SPACE 84 SUBTOTAL 20 1 1 1 7.7 It 5 9 CIRCUYPE : Q ARC FAULT Q TIME SWITCH CONTROL NWN CU' SUBTOTAL SECTION 1 12.8 1 10.7 12'5 ® cT TRIP ®GROUND FAULT @ DEDICATED © ISOLATED GRD. TOTAL KVA IS 89.7 KVA TOTAL AMPERES IS 249.2 AMPS POLE TRIP TYPE 3 PHASE 4 WIRE O EQPT. GRD. 0 ISOL. GRD. MAII M.L.O. O BREAKER : I— — ❑BUSWAY BRAtPOLES: 42 BRANCH BREAKERS= 10 KAIC RISER M FREE STANDING CJ KEYED DOOR BUSING: 400A I BRACING = 10 KAIC D FLUSH 0 K RATED. {1.5} D K RATED {2.0} GROBAR: 0 EQUIPMENT 0 ISOLATED EJ BOTH ®FULL SIZE CLASS( ) DIV ( ) FEECATION: p TOP ED BOTTOM ® FEED THRU Z1 NEMA 3R 17-1 NEMA 4X FED)M: MNORMAL 0 EMERGENCY O UNINTERRUPTABLE ZI CB PLUG IN 0 CB BOLT IN NOTE: E y = EXISTING t, rw r-rohl IIT RRFAKFR TO MATCH EXISTITYPE Delta G Consulting Engineers, Inc. 707 N.E. 3rd Ave. Suite 200 Fort Lauderdale, FL 33304 (954) 527-1112 Tel. (954) 524-7505 Fax www.DeltaG.net PROJECT #: 160504 PROJECT MANAGER: S.B. DESIGNED BY: C.B. C.A.#: 00009181 DATE: 05/16/2016 o A v B A 8 A /5� 0,11 L7 U Q W U vs H U r�Zj � E-+ PROJECT #: 160504 PROJECT MANAGER: S.B. DESIGNED BY: C.B. C.A.#: 00009181 DATE: 05/16/2016 SEAL. Vit)LX o A v B A 8 A /5� 0,11 /111111M Copyright 2011 Material shown new. is me ,opor,ghteu Property c* DHta 6 r Consulng-cnaineers�nc aanJ stall Mot Le rgr�iuwa M 401E, r ti e in�art wiLouYex;.re6 watt6 piJmEsiE:n. r . .•