Loading...
PERMIT DOCUMENTS L/76y Emile Damisse, PE49408 2654 Sawyer terrace Wellington, Florida 33414 Wellington, Florida January 15, 2017 Ref: Residence: BARREAU HENCIE 647 SW 4T" AVE, BOYNTON BEACH, FL 33435 Based on (ASCE-7-10), for Wind speed of 150 MPH, negative wind pressures on the walls and windows in Zone 4 and 5, are for exposure B as follows: Zone 4: -43.9 PSF Zone 5: -54.2 PSF Four windows with"Extruded Aluminum Tube Mullions" were installed in conformity with NOA No. 11-1213.07. One window is in Zone 5 and the other 3 are in zone 4. The size of these windows are as follows: Width: 37 3/8"and Span: 49 5/8". The size of the mullions used is 1x4" and the anchors used are of type A4. This corresponds, based on the manufacturer specifications, to a maximum wind load resistance capacity of 119.3 PSF, which is much higher than the actual wind pressure of 54.2 PSF. 2x2x1/8" Aluminum angles were used. These angles are attached to the concrete tie beams using 'b" Dia. x 2-3/4" tapcons, two per angle. #14 sms were used,two per angle, 1-3/4"o. c. . r Sincerely `l C,1, G Emile Q: iise'P, 49408 ,o> a� . . •r,N