DRAWINGSAn An An 00 An An idwo r APF Drawing List: Sheet Title No. Index 1 G-0 COVER SHEET 2 G-1 FUEL DISPENSERS &POS SITE PLAN 3 G-2 DISPENSER DETAILS z m W Q REVISIONS LEGEND: DATE ISSUED: 11-18-2013 DATE REVISION No. 1 Y CL, REVISION No. 2 U REVISION No. 3 Florida Department of Environmental Protection: Facility ID Number 8520561 Site Parameters: Zoning: C-3 Community Commercial Use Type: 2600 -Service Station ITHIS DRAWING IS THE PROPERTY OF AEC SERVICES INC. AND HAS BEEN PREPARED SPECIFICALLY FOR THE OWNER OF THIS PROJECT AT THIS SITE; IT MAY NOT BE USED FOR ANY OTHER PURPOSE, LOCATION, OR OWNER A' 2605 West Woo/bright Road Boynton Beach, Florida 33436 PREPARED B Y AEC Services, Inc. ENGINEER OF RECORD: RON FAIR, P.E. FL #50738 Q13#0011445 LIC.#9277 1616 ALLISON WOODS LANE TAMPA, FL 33619 PHONE: (813)684-1234 FAX: (813)684-2660 www.aecservicesinc.com Palm Beach County Parcel Control #: 08-43-45-31-17-001-0020 OVicinityPlan 4 NOT TO SCALE '� B�;a,' d CONSTRUCTION WILL CONFORM TO THE FOLLOWING CODES & STANDARDS: Florida Building Code -Building 2010 Edition. Florida Building Code -Plumbing 2010 Edition. Florida Building Code -Mechanical 2010 Edition. Florida Building Code -Fuel Gas 2010 Edition. Florida Fire Prevention Code 2010 Edition. National Electrical Code (NEC) 2008 Edition. ACI -318-05: American Concrete Institute. AISC-360-05: American Institute of Steel Construction. NFPA 30: Flammable & Combustible Liquids. NFPA 30A: Motor Fuel Dispensing Facilities. NFPA 37: Stationary Combustion Engines and Gas Turbines. NFPA 70: National Electrical Code 2008 Edition. NESC: National Electrical Safety Code 2012 Edition. PEI / RP 100-05: Petroleum Equipment Institute / Recommended Practice. CHAPTER 62-761: Florida Administrative Code. Florida Department of Environmental Protection. City of Boynton Beach Administrative Amendments. GENERAL NOTES: 1- Contractor to field verify all measurements and notify Engineer in writing 48 hours prior to start. 2- During construction, all areas are to be secured with flashing barricades or better. 3- All material and equipment to be used must be FDEP approved. "CALL BEFORE YOU DIG" In Florida, The Law Requiring Excavators to Call 811 Before Digging is the Underground Facility Damage Prevention and Safety Act, Chapter 556, Florida Statutes. Failure to call can result in fines from $250 to $5,000. U _0 M E Zt mmco CL }, M a W Cn 'L -0 E T_ CM O O NC� U) U O O U � co N N CD M o- C) w h o 0 r LL N O Cl) m 6� C0 66 LU w 0 0 Q w �_ J (q U 0 1 � �co P 1S1 X" 11110®e U W z J E _ o 0 M M 8 E W m (n J � cD UaCi Jam, N J 'a'OC) d' a) o < co04 M Q r r 1 o z ���00 O X a� �W o 0 U N LU = ti. V N LL J 00 U M Z WLO zQ Z W LL to I ­ W r Y CL, LL a U 'z v' r z m W Q Q m W OD O Z 0 Z LL U p Z U W p X 0 WW X 0 U d Q LU a 0 0 Z 00 Z a U U) Uj� W 0 W CO to ch M N r F9 U) O ,i. D NOV 2 12013 1 BUILDONG DeVescom OP `R TY (3) EXISTING UNDERGROUND ELECTRICAL CONDUIT @ EACH DISPENSER: (TYPICAL OF 9 DISPENSERS) 1-1"0 GALV. RIGID CONDUIT -POWER WIRING -ALL POWER WIRING TO BE REUSED. 1-3/4"0 GALV. RIGID CONDUIT -INTERCOM WIRING- TO BE REPLACED WITH (1) Cat6 CABLE. 1-3/4"0 GALV. RIGID CONDUIT-VEEDER ROOT SUMP SENSOR -WIRING & SENSOR TO REMAIN. PROPOSED GAS BLENDER WITH DIESEL DISPENSER TO BE REPLACED (TYPICAL OF 1) PROPOSED GAS BLENDER DISPENSER TO BE REPLACED (TYPICAL OF 5) L L.3 IRRK" 0 AD V %V E- cc'�%)T VV" 0' Q Fuel Di NOT TO SCALE THIS DRAWING IS THE PROPERTY OF AEC SERVICES INC. AND HAS BEEN PREPARED SPECIFICALLY FOR THE OWNER OF THIS PROJECT AT THIS SITE; IT MAY NOT BE USED FOR ANY OTHER PURPOSE, LOCATION, OR OWNER DISPENSER LEGEND: GASOLINE BLENDER (3+0) ENCORE 70OSD NN1 Il GASOLINE BLENDER WITH DIESEL (3+1) ENCORE 70OSD NL1 ensers & POS Site Plan Overview: The proposed scope of work is to change out / upgrade the existing fuel system dispensers and point of sale system from Wayne Vista dispensers to new Gilbarco Encore 700 Dispensers. This upgrade is being performed to meet current Payment Card Industry Data Security Standards and provide a technology platform to meet future EMV security standards (Chip and PIN) that are to be implemented in the year 2017. Petroleum Scope of Work: 1. Disconnect existing product lines from top of impact valves so existing Wayne Vista dispensers can be removed. All work is to be performed above the impact valves. The existing Stage II vapor recovery system has already been decommissioned and disconnected. New dispensers will not be equipped with Stage 11 vapor recovery. 2. Disconnect and remove existing Wayne Vista dispensers. Dispenser inlets are to be properly capped and secured for transportation. All dispensers are to be saved in as is condition and transported to storage yard for resale to Pump Remanufacturer. 3. Wipe Down and rough clean existing dispenser containment sumps prior to new dispenser installation. 4. Install new 7 -Eleven furnished Encore 700 dispensers over existing under dispenser containment sumps. Secure dispensers to existing concrete as per manufacturer's requirements and engineers detail. 5. Extend product piping from top of impact valve to dispenser inlets. 6. Install new 7 -Eleven furnished hanging hardware IE: Hose / Nozzle Assemblies, Hose Retractors on diesel dispenser only. 7. Furnish and install appropriate Mobil and Fl. Dept. of Ag. Decals on dispenser. 8. Dispenser start-up, calibration and point of sale installation to be performed by manufacturers certified start-up technician. Start-up technician to submit a placed in service report to the Florida Department of Agriculture and Consumer Services, Division of Standards, Bureau of Petroleum Inspection for all new dispensers and meters being placed into service. Please note that when dispenser upgrades are performed and all work is performed above the dispenser impact valves. Environmental permitting, inspections or product line testing is not required by the Palm Beach County Department of Environmental Resources Management for the petroleum scope of work being performed. For questions regarding environmental permitting and testing requirements, please contact: Patrick Wille Storage Tank Compliance Program Supervisor PBC Dept of Environmental Resources Management 2300 North Jog Road, 4th Floor West Palm Beach, FL 33411-2743 561-233-2505 Office 561-233-2414 Fax pwille@pbcgov.org Electrical Scope of Work: 1 Properly Lock -out / tag out all fuel system dispensing devices and pumps prior to any work being performed. 2. Disconnect power, data and intercom wiring under existing dispensers so dispensers can be removed. All existing underground dispenser power and data wiring is to be saved, secured for reuse. The proposed scope of work is based upon reusing existing power and data wiring to the dispensers. 3. Disconnect and remove existing Wayne interface box and install new Gilbarco Data Box. 4. Upon installation of new dispensers, reconnect existing power and data wiring to new dispensers. The installation of an approved junction box and/or extending the existing wiring shall be permitted to properly connect new dispensers. All wiring methods shall comply with 2008 NEC Article 514 Note: Because future payment card industry technology will require high speed communication to the dispenser. This can be achieved two ways as per Gilbarco's installation instructions. One is to utilize dispenser data communication wiring if it meets Gilbarco installation specification requirements and the second is by the use of a 10 base T or Ethernet connection using a minimum Cat5 Cable. It is 7 -Eleven's direction that if the existing data wiring to the dispenser does not meet Gilbarco's minimum standards and a new means of communication must be installed for future use, The preferred method of communication would be an Ethernet connection and installing a Cat6 underground cable with a fully flooded gel core. Ethernet cabling cannot be installed with power wiring and must be installed in the Low Voltage / intercom raceway. 5. Current dispenser data wiring is believed to not meet Gilbarco's requirements for future high speed communication. Contractor is to furnish and install (1) new Cat6 underground cable with fully flooded gel filled core to each dispenser. New cath cable is to be installed in the existing intercom raceway to each dispenser. a. Disconnect existing intercom cabling to each dispenser and clear existing electrical seal fittings (replace as needed). b. Remove existing intercom wiring so new Cat6 Cable can be installed to dispensers. c. Furnish and install new intercom wiring and new cath cabling to each dispenser. i. Cat6 Cable: Vertical Cable #069-560/CMXF Direct Burial, Gel Filled (Flooded Core) ii. Intercom Cable West Penn AquaSeal AQC359 Intercom / Audio Cable d. Properly pack and pour electrical seal fittings with approved materials as per manufactures specifications. e. Re -terminate all dispenser intercom wiring and test system for proper operation upon completion. f. Future Cat6 cables are to be routed to the dispenser interface area and with each fueling position number for future use. 6. Upon completion of dispenser upgrade, test fuel system emergency stop system for proper operation. Fuel system is not to be returned to service without a fully functional fuel system emergency stop system and a means to reset that is acceptable to the authority having jurisdiction. NEC 514.11 (A) and (B), NFPA 30A 6.7 and 6.7.1 r; 12013 31 U LU o C n a Z M RS E N M M QOM Z r-- CU M '_ CU Q W C w '`- O M Z 0 O O U (n 0 U N N CU O 0 X > O 00 n- O �- W O Q I L0 ~ C O O V- � A N O cA LU a m cri U) (moi) o U) W Q o Q W _H J U (n Z 00 z �... 7 mj co I�- . L0 LL laltl#1111 U w Z — V) Q J E LA0 0 U v ., Cn o 0 M co (00 V a g _JL J Coy ti Q a (0 c0 co M M M LUL a Z � QCID 6 0 O w N 0 O � LL t�j N J U 00 M Z W � z> z itZ tJi. �O UJ d M 04 � cr)c� LU o 0 ZZ n a Z U Z ccccQ Q °° w > pp o Z 0 Z w U (n 0 Z � U _ O Q_ 0 X U Q LU a 0 U) Z 00 z a. R — V) U (n LU \ 0 W c0 u� d M 04 Z a_R� L cc co a. F_ EXTEND PRODUCT PIPING IF NEEDED TOP OF EXISTING SHEAR VALVE TO REMAIN EXISTING PRODUCT PIPING TO REMAIN EXISTING--"`—� DISPENSER SUMP TO REMAIN 3/4" BREAKAWAY OPW 66REC-1000 3/4" x 8' FLEXSTEEL SPACER HOSE GOODYEAR GY3/4X8MXM 3/4" NOZZEL OPW 11 B-0100 BLACK SPLASH FOR GAS 8BL-0400 GREEN SPLASH FOR DIESEL 8G-0100 - 3/4" SWIVEL OPW 241TPS-0241 EXISTING 1/2" O "J" BOLT TO BE REUSED, IF NOT REUSEABLE USE ALTERNATE 1/2"0 x 4" LONG WEDGE ANCHOR BOLT. (TYPICAL OF 4 PER DISPENSER). EXISTING EXPLOSION PROOF JUNCTION BOX & SEAL OFF TO REMAIN \-EXISTING GALV. RIGiD CONDUIT & WIRING TO REMAIN, ONLY INTERCOM CABLE TO BE REPLACED WITH Cat6 CABLE EXISTING DISPENSER SUMP SENSOR & WIRING TO REMAIN Fuel Dispenser Detail NOT TO SCALE EEN PREPARESPECIFICALLY FOR TH THiS DRAWING IS THE PROPi SITE; I�FMAYCNOTRBE USEDC FORD DANY OTHASBHER PURPOSED LOCATION, OR OWNER E OWNER OF THIS PROJECT AT THIS MOBiL STANDARI IN DISPENSER V/ FIRE MARSHAL FUELING WARN AT COLUMN NE TO DISPENSER MOBIL STj LOGO AT 1 OF DISPE ACCESS Dispenser Decals Detail NOT TO SCALE VAPOR 3/4'X t I/2 SLOTS FOR ANCHOR NOTES' I INCH NPT, WAYNEVAC48- BOLTS: 8 PLACES. SEE NOTE 5" N RECOVERY OUTLET, OPTIONAL AND ELECTRICAL INSTALLATiONS,MUST SEE NOTE'8 AND t, ALL PIPING CONFORM TO ALL APPLICABLE REGULATIONS INCLUDING SEE ATTENTIONI NOTE 21---- 7i93•C NFPA30, FLAMMABLE b C0MB05716LE LiOUIDS'CODEI • PT 4 I t3 NFPA30A,. AUTOMOTIVE b MARINE:SERVICE STATION CODE; REV pAZO NATIONAL ELECTRICAL CODE, 00 NOT "DAISY CHAIN" INLET 3 !� 1-- 9-"x-102- ICSI -TOP OF ISLAND THE DISPENSER POWER CIRCUIT TO ANY OTHER EQUIPMENT. it PIPING FROM TANK TO OISPENSER.SHOULO,SLOPE3- 2. UPWARDS TO'AVOIO AIR OR LIOUktI TRAPS. USE UNIVERSAL JOtNTS.AT DISPENSER TO ALLOW FOR , 14-3/16` 6' 3. k _ - -- - fE 20 31 GROUND MOVEMENT. i3 I11 - - 7 --t- } 2 DIT TAPS SHOWN TO MAKE 2 T, 4 . USE ANY OR ALL CONDUIT 62 4 ELECTRICAL CONNECTIONS TO DISPENSER, i _ 5. F IRML . YUNT THE DISPENSER MOTO THE ISLAND USING: THE .... � - - ANCHOR BOL7 LOCAitflt3S.:SHOWN, - 3 1 INCH NPT CONDUIT TAP SECTION THRU BASE 6. EMERGENGI' SHUTOFF VALVES AND BREAKAWAY DEVICES' 3 3"PLACES. SEE NOTE 4 ARE EXAMPLES OF REQUIREMENT5- STATED IN THE _ { 6g NFPA30A AUTOMOTIVE d MARINE SERVICE:$TATION THESE .AS WELL, AS ANY ;OTHER;:SAFETY ATTENT I �N CODE. DEVICES:AEOUiRED BY NFPA30 b 30A,:MUST BE OUTLET INSTALLED AND 'MAINTAINED -PER THE I INCH NPT.BALANCE WAYNEVAC VAPOR MANUFACTURER S INSTRUCTIONS. VAPOR RECOVERY MOVED 'TO CURRENT LOCATION HIGH FEED STOCKS MUST BE PLUMBED AS. SHOWN: OUTLET. OPTIONAL AS SHOWN ABOVE, EFFECTIVE, 7; THE LOW AND ti SEE .NOTE $ WITH DISPENSER DATE COOE'COO FOR THE DISPENSER TO WORK PROPERLY. OPTION AL SPEAKER I NSTALLAT 1ON W I R l NG { S i.00ATEO `i N DIMENSIONS E3• iiiNGTION''BOX: CONNECT INTERCOM CiRCUiT TO A LISTED: BASE CLASS 2`POWERED INTERCOM ONLY WITH I8 GAUGE MINIMUM, AT LEAST 90:DEGREE C,; '600 V GAS 41311L RESISTANT UL LISTED WIRE. WIRES BACK TO INTERCOM POWER -MUST BE RUN IN SEPARATE DEDICATED LISTED METkL-IC 'CONDUIT, 'OPTIONAL VALANCE - g, BALANCE.. VAPOR RECOVERY AND WAYNEVAC VAPOR RECOVERY"°'" CONNECTIONS ARE IN DIFFERENT LOCATIONS. s A io INCH MINIMUM CLEARANCE FRM. THE TOP DISPENSER ISaRECOMMENDEDf A 1-1/21 INCH MINIMUM CLEARANCE, TO ALLOW REMOVAL OF THE FROM THE OUTSEOE'SURFACE OF COLUMN OPTIONAL VALANCE AND TOP IS:RECOMMENDED TO ALLOW REMOVAL OF COVER FOR SERVICE. COVER PANELS.FOR SERVICE.• © 94 1-1/2 NPT INLET UNION, 3 PLACES JUNCTION BOX i INCH NPT WAYNEVAC VAPOR DRAIN TAR --2 13- I1 316� _ EMERGENCY VALVES', 3 PLACES LOW _FEED STOCK •--- -- UNI V_ ERSAL JO I NT e 3 PLACES HIGH FEED STOCK SEE NOTE 3 TOLERANCES SEE NOTE 2. S i NGLE PRODUCT - !� JUNCTION BOX SIDE i 1/4 INCH 2/V595D SHOWN UNLESS OTHERW i SE'SPEC I F 1 ED FUEL POSITION # :,REDIT CARD ACCEPTANCE GASOLINE NOTE OF MAK 10% ADDED ETHANOL DISPENSER USE NOTES NOTE: DISPENSER COLORS PER MOBiL STANDARDS. (VERTICAL ONLY) ALiNG COMPOUND MING FIBER (VERTICAL OR HORIZONTAL) DAMMING FIBER SEALING COMPOUND AMMING FIBER DTE: PROVIDE EXPLOSION PROOF SEALS. IN ACCORDANCE ARTICLE 501, CLASS 1, 4 OF I Ill- SION ELIECTRiCAL TH CODE TYPICAL OR'A L UNDERGROUND CONDUIT STUB -UPS INTO EQUIPMENT Seal Off Detail NOT TO SCALE _ . NOTES: I INCH NPT WAYNEVAC VAPOR 3/4 X I PLACES. S FOR TEANCHOR RECOVERY OUTLET. OPTIONAL �8 BOLTS $PLACES. SEE NOTE 5 Ii ALL PIPING AND ELECTRICAL. INSTALLATIONS MUST SEE -NOTE 8 CONFORM TO ALL APPLICABLE REGULATIONS INCLUDING SEE ATTENTIONt'NOTE 2103•e NFPA30", FLAMMA13Li d COMBUSTIBLE LtOUIQS;COOE. 2t� REV E NFPA3OA, AUTOMOTIVE d MARINE SERVICE STATION CODE I Q { NFPA70, NATiO,NAt ELECTRCCAI CODE: DO NOT "DA INLET I-1/2 NPI - 9 141 10 9 DISPENSER`POWER CIRCUIT TO ANY OTHER EOUIPMENT, INLET 2 PL S 2. 2 TOP OF ISLAND THE 2. PIPING FROM TANK TO DISPENSER SHOULD SLOPE 1t ' 316. � UPWARDS 10 AVO 10- A I R OR L 1 OVI0; TRAPS. - 3. USE UNIVERSAL JOINTS AT DISPENSER TO ALLOW FOR GROUND `MOVEKNI .- k3 Iii 4. USE ANY OR ALL, CONOiJiT TAPS SttOwN 10 UAKE 2 6{ ;i J -w - ELECTRICAL CO►•►•�C.TIQrtS TO' D15PEtfETt. 2 4 5, FIRMLY MOUNT TIC OISPEW111 TO ttit ISLMD.If`0t4G WE ANCHOR BOLT LOCATIONS SHOWN. - 3 6. EMERGENCY SHUTOFF VALVES ANO BREAKAWAY DEVICES3� - I INCH NPT CONDUIT TAP SECTION THRU'BASE ARE EXAMPLES OF AE STATED iN THE - 63 3 PLACES.SEE NOTE' 4 NFPA30A AUTOMOTIVE A MAR:INE'SERVICE STATION 4 S WELL AS ANY OTHER SAFETY 19 CODE. THESE, A t�`�-- � ATTENT: I QN Y DEVICES REOUIRED 8Y I4FPA30 d 3OA:, MUST --BE INSTALLED AND MAINTAINED PER THE NCH .NPT BALANCE WAYNEVAC VAPOR OUTLET MANUFACTURERS INSTRUCTIONS. I t MOVED TO. CURRENT LOCATION S"MUST BE PLUMBED AS SHOWN VAPOR RECOVERY AS SHOWN ABOVE, EFFECTIVE 7. THE LOW AND HIGH FEED STOCK PROPERLY: OUTLET. OPTIONAL WITH DISPENSER DATE. :CODE .COO FOR THE DISPENSER T6WORK PRO _ SEE NOTE S TIONAL SPEAKER_:INSTALLAT{ON WIRING IS LOCATED IN t3• JUNCTION BOX.. CONNECT INTERCOM CIRCUIT°TO A LISTED . BASE DIMENSIONS CLASS 2 POWERED INTERCOM ONLY WITH 1046AUGE MiNIMUM, AT;LEAST 90: DEGREE .C, 600 V GAS b OIL RESISTANT UL LiSTEO WIRE. WIRES BACK TO INTERCOM POWER 'MUST8E RUN IN SEPARATE.DEDCATEO.LISTED METALLIC CONDUIT. g, BALANCE VAPOR RECOVERY AND WAYNEVAC VAPOR RECOVERY OPTIONAL VALIANCE CONNECTIONS ARE IN DIFFERENT LOCATIONS. L J t A 10 INCH !A I t1 I MUM CLEARANCE FROM THE, TOP OF A 3-E/2 INCH .MINIMUM CLEARANCE DISPEN5ER IS RECOMMENDED FROM :THE 00ii E SURFACE OF COLUMN, TO ALLOW REMOVAL OF THE OPTIONAL VALANCE AND TOP IS RECOMMENDED TO ALLOW REMOVAL OF COVER PANELS -FOR SERVICE.. COVER FOR SERVICE 94 1-1/2 NPT INLET UNiON, 2 PLACES --- JUNCTION BOX I INCH NPT WAYNEVAC VAPOR DRAIN TAP 2 I34 3 E6 — EMERGENCY VALVES, 2 PLACES . LOW FEEDSTOCK' UNIVERSAL JOINT, 2 PLACES HIGH FEED STOCK SEE NOTE 3 TOLERANCES SEE NOTE.2 JUNCTION BOX SIDE t 1/4 INCH 2/V5900/U SHOWN UNLESS OTHERWISE SPECtFiEO Figure C-2. 2-7193-C Installation Instructions - 2IV590D, 2IV59OD/U, and 2/V595D/U (Remote) C? C ti`0 cri ® 0M N CF) �id(1i cM All 't i i1 ' (0 to CO Cr -I-- -a •L L W pO Q LL o 0a)> N m L � a� � a_ o a- W o o N 0 N LU U) W W � p Q p F_ Q Z Mw - w U � Nz ® ®° Z a ACNu 03 AX _ cs w V Q E "t 00o V_ o rA o 3: Z (00 V i`° U 0 a), 0In o_jNLL 7 w LC� wo `r ..�. ti Q d 0) cm c( co ;>N ft w r c) zZ (0 o00 0 O (D OC N o 0 V J C: N LL J !YLLI M Q pLOLf)M , N O °1LL - r 0 Z p E E ICLi w-- m w Q Z Z Z U 0 Z U > m O U_ w n= U.1 U 0- p X p Q 7 ­ F F!a� z 0 G. I 1116 1> UU) W D W w %1 VA NOV 21 2M FiL 0 BUILDING DIVISION w ­tIcoINI-1°1 1 G-2