DRAWINGSFIFTIP =G-mm'I V w • ww t� t Olt Ar • M %-90 V) 24 X 9S CLEMPRKM L. "XW _7 7 TOP ZOM-12•LgF_ Yi REMAINING BACKFILL, BASE & SURFACE MATERIAL TO BE PLACED AND COMPACTED PER APPROPRIATE SPECIFICATIONS OR MINIMUM 98% PER AASHTO T-180. 6" MAX. SIZE. (MIN. 95% DENSITY IS REQUIRED FOR UNPAVED AREAS). COYM ZOPE - it LJFTS GRANULAR BACKFILL PLACED AND COMPACTED TO MINIMUM 98% OF MAXIMUM DENSITY. PER AASHTO T-180. 24" MIN. I 24""MIN. 2" MAX. SIZE. ------------ „ 7 '\ SEDDM ZOM - V L rrm MINIMUM 98% COMPACTION. PER- AASHTO T-180. G {SEE NOTE 5 & 6) -- WHERE APPLICABLE; OVEREXCAVATION IS NOT CDR BOX s PREFERRED IF DEWATERING IS NOT REQUIRED PIPE AREA REQ'D PIPE 3T MODEL NO. SIZE SIZE DRIVEWAY FOR OTHERS B in 1. BEDDING SHALL CONSIST OF IN-SITU GRANULAR MATERIAL OR WASHED AND GRADED UMEROCK 3/8"-7/8" SIZING, ONLY AT THE 3" OMNI C2 (OMNI 413) DIRECTION OF THE CITY'S REPRESENTATIVE. UNSUITABLE IN-SITU MATERIALS SUCH AS MUCK, DEBRIS AND LARGER ROCKS SHALL BE 17x30 FLARED 17" REMOVED. mm 2. THE PIPE SHALL BE FULLY SUPPORTED FOR ITS ENTIRE LENGTH WITH APPROPRIATE COMPACTION UNDER THE PIPE HAUNCHES. U I 0 14" 18.6 SQ. FT. 3. THE PIPE SHALL BE PLACED IN A DRY TRENCH. 0 • 4. BACKFILL SHALL BE FREE OF UNSUITABLE MATERIAL SUCH AS LARGE ROCK, MULCH AND DEBRIS. m v 5. DENSITY TESTS ARE REQUIRED EACH LIFT ABOVE THE PIPE AT INTERVALS OF 100' MAXIMUM IN PUBLIC RIGHTS OF WAY & 200' PRESSURE A MAXIMUM IN UTILITY EASEMENTS. c 6. THE DEVELOPER/CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE TRENCH SAFETY LAWS AND REGULATIONS. RECLAIMED 7. SEE SEPARATE DETAIL FOR "ROAD CROSSING PIPE INSTALLATION UNDER EXISTING ROADWAY." a 8. THE AFFECTED AREA SHALL BE RESTORED TO EQUAL OR BETTER CONDITION AS REQUIRED. 36" I 9. EXCAVATION SIDE SLOPE SHORING, ETC SHALL CONFORM TO O.S.H.A. STANDARDS. COMPACT TRENCH BACKFILL TO 987. OF MAXIMUM y MAX. C DENSITY IN ACCORDANCE WITH AASHTO-T180. DIP BOYNTON BEACH UTILITIES DEPARTMENT CONSTRUCTION STANDARDS & DETAILS SEC'.1 M A -A NOT TO EFF. DATE TYPICAL TRENCH DETAIL SCALE I 01/13 END OF CITY I WITH BOX UTILITIES OWNERSHIP & I PAGE NUMBER ENGINEERING DIVISION G-5 Print - Maps Page 1 of 2 bing Maps 97 North Blvd, Boynton Beach, FL 33435 My Notes http://www.bing.com/maps/Print.aspx?mkt=en-us&z-- l 7&s=r&cp=26.5134... 12/6/2013 CLEAR RWO ' w i L_ r� v ALL BUSHINGS OR REDUCERS ! E SHALL BE BRASS 'v 1-1/2" TO 2" ABOVE FINISHED GRADE IN GRASSED AREA. 0" IN PAVED AREA. {SEE NOTE 5 & 6) PIPE CDR BOX s R/W LINE FOR ROADS. BACK OF PIPE AREA REQ'D PIPE / CURB/SIDEWALK OR EDGE OF MODEL NO. SIZE SIZE DRIVEWAY FOR OTHERS B C i LIMIT OF MIN. UNOBSTRUCTED 3" OMNI C2 (OMNI 413) SPACE/CLEAR ZONE 17x30 FLARED 17" E-- - - _ \ 6" I 0 14" 18.6 SQ. FT. � z Bldg. #90 South Blvd. M GRASS AREA m v - - PRESSURE A 4" MIN. � TEST LIMITS RECLAIMED MIN. DIP (TYP.) t 1 i 36" 36" I MAX. C DIP SEC'.1 M A -A GATE VALVE 1 DIP END OF CITY I WITH BOX OWNERSHIP & I MAINTENANCE j RESPOSIBIUTY i i i = 'to � APPROVED 30"x48" METER BOX AND (LID NOT SHOWN) L.-- -- -- •----------.------. !i 1 4'-8" r� v ALL BUSHINGS OR REDUCERS ! E SHALL BE BRASS 'v 1-1/2" TO 2" ABOVE FINISHED GRADE IN GRASSED AREA. 0" IN PAVED AREA. OWNER I I MIN. SETBACK I - FOR POWER TRANSFORMER PAD ►-I Zi Uj WI �I (51 ox I L 350)I METER TO BE SET BY DEPARTMENT r 24" MIN. DEPTH -- DIP (CL 350) 3/4" WASHED ROCK WITH FILTER FABRIC UNDER METER BOX METER SENSM METER PIPE CDR BOX s o PIPE AREA REQ'D PIPE SIZE MODEL NO. SIZE SIZE A B C D E 3" OMNI C2 (OMNI 413) 0 17x30 FLARED 17" - 24" _ 36" 6" 11-1/4': BEND 20% DEAD END: 100% 0 14" 18.6 SQ. FT. 16" 24.0 SQ. FT. z Bldg. #90 South Blvd. m v - - PRESSURE A TEST LIMITS RECLAIMED MIN. DIP WATER MAINMIN.B MAX. C SEC'.1 M A -A OWNER I I MIN. SETBACK I - FOR POWER TRANSFORMER PAD ►-I Zi Uj WI �I (51 ox I L 350)I METER TO BE SET BY DEPARTMENT r 24" MIN. DEPTH -- DIP (CL 350) 3/4" WASHED ROCK WITH FILTER FABRIC UNDER METER BOX METER SENSM METER PIPE CDR BOX Bldg. #220 Main Blvd. NOTE: PIPE AREA REQ'D PIPE SIZE MODEL NO. SIZE SIZE A B C D E 3" OMNI C2 (OMNI 413) 3" 17x30 FLARED 17" 1 20" 24" 1 23" 36" OI I wl 01 wl BOYNTON BEACH UTILITIES DEPARTMENT CONSTRUCTION STANDARDS & DETAILS NOT TO RECLAIMED WATER 3" AND LARGER SCALE EFF, DATE SCALE 12/12 METER SERVICE DETAIL PAGE NUMBER R-1 .e,*sa�' Ir 1003 N. W I]'* street p�0 ��` • Boynton Beach, FL 33426 61 734-3997 Fax (561) 734-3377 csi'ad Inc. Dec. 9, 2013 To: City of Boynton Beach- Engineering Re: Comments Application #13-00003954 Comment #4 - All road crossings will be excavated, piped and backfilled one at a time to reduce the time associated with crossing the road. We will pre -fabricate piping as practical so that the piping can be installed as soon as the excavation is complete. Backfill and preliminary compaction will occur after pipe is installed. Patch work on the existing asphalt will be done by The Paving Lady and start after the piping installation and again be done one at a time. Please let me know if any further explanation is necessary. Best Regards, Bob Irsay IE - 10 a 6" MIN. #5 REBAR MIN. TWO REQUIRED. BEND TO FIT & PAINT WITH 2 COATS BITUMINISTIC PAINT BEFORE ASSEMBLY u ''g WIDTH\` SOIL 77 12" MIN. THICKNESS OF CONCRETE TYPICAL n E 1. THRUST BLOCKS SHALL BE FORMED AND POURED AGAINST UNDISTURBED SOIL. KEEP "r BOLTS CLEAR OF CONCRETE, WRAPPED IN VISQUEEN FOR FUTURE ACCESS, WITH A MINIMUM OF 12" THICKNESS BETWEEN THE FITTING AND THE SOIL. 2. BEFORE POURING, PLUGS SHALL BE WRAPPED WITH VISQUEEN AND A BOARD PLACED IN FRONT. 3. CONCRETE SHALL BE 2500 P.S.I. MINIMUM (28 DAY STRENGTH). 4. FITTINGS 16" AND LARGER SHALL HAVE MECHANICAL RESTRAINT, AND THRUST BLOCKS. 5. THE ENGINEER OF RECORD SHALL CALCULATE THE SIZE OF THE DEADMAN REQUIRED AS WELL AS ANY INSTALLATION WHICH IS NOT COVERED BY THE ABOVE. BOYNTON BEACH UTILITIES DEPARTMENT CONSTRUCTION STANDARDS & DETAILS NOT TO EFF. DATE TYPICAL THRUST BLOCKS SCALE 01/13PAGE NUMBER G -1O High Point West- Water Schedule The existing zones use between 40 to 80 gallons per minute for an average of @60 gpm The system piping is set up to run 3 existing manifolds at one time for an average of @180 gpm. Grouts A- Monday, Wednesday and Saturday #1- 12am to 2am THRUST BLOCK Bldg. # 320 North Blvd. THRUST BLACK Bldg. #220 Main Blvd. NOTE: PIPE AREA REQ'D PIPE AREA REQ'D REMARKS FOR OTHER FITTINGS Bldg. #210 Main Blvd. Bldg. #110 South Blvd. #3- 4am to 6am USE THE FOLLOWING FACTORS. TEE: 100% 45' BEND: 71% 22 1/2' BEND: 39% 4" 2.0 SQ. FT. 20" 37.0 SQ. FT. VALUES ARE FOR 90- BEND, BASED ON 2000 P.S.F. SAFE BEARING LOAD AND PIPE PRESSURE OF 150 P.S.I. FOR OTHER SOILS & PRESSURES THE 6" 4.0 SQ. FT. 24" 53.0 SQ. FT. 8" 6.6 SQ. FT. 27" 80.0 SQ. FT. 10" 10.0 SQ. FT. 98.0 SQ. FT. Group B- Tuesday, Thursday 30" AREA REQUIRED IS IN DIRECT PROPORTION 11-1/4': BEND 20% DEAD END: 100% 12" 14.0 SQ. FT. 36" 127.0 SQ. FT. 14" 18.6 SQ. FT. 16" 24.0 SQ. FT. 18" 30.0 SQ, FT. 1. THRUST BLOCKS SHALL BE FORMED AND POURED AGAINST UNDISTURBED SOIL. KEEP "r BOLTS CLEAR OF CONCRETE, WRAPPED IN VISQUEEN FOR FUTURE ACCESS, WITH A MINIMUM OF 12" THICKNESS BETWEEN THE FITTING AND THE SOIL. 2. BEFORE POURING, PLUGS SHALL BE WRAPPED WITH VISQUEEN AND A BOARD PLACED IN FRONT. 3. CONCRETE SHALL BE 2500 P.S.I. MINIMUM (28 DAY STRENGTH). 4. FITTINGS 16" AND LARGER SHALL HAVE MECHANICAL RESTRAINT, AND THRUST BLOCKS. 5. THE ENGINEER OF RECORD SHALL CALCULATE THE SIZE OF THE DEADMAN REQUIRED AS WELL AS ANY INSTALLATION WHICH IS NOT COVERED BY THE ABOVE. BOYNTON BEACH UTILITIES DEPARTMENT CONSTRUCTION STANDARDS & DETAILS NOT TO EFF. DATE TYPICAL THRUST BLOCKS SCALE 01/13PAGE NUMBER G -1O High Point West- Water Schedule The existing zones use between 40 to 80 gallons per minute for an average of @60 gpm The system piping is set up to run 3 existing manifolds at one time for an average of @180 gpm. Grouts A- Monday, Wednesday and Saturday #1- 12am to 2am @180 gpm Bldg. # 320 North Blvd. Bldg. #220 Main Blvd. Bldg. #120 South Blvd. #2- 2am to 4am @180 gpm Bldg. #310 North Blvd. Bldg. #210 Main Blvd. Bldg. #110 South Blvd. #3- 4am to 6am @180 gpm Bldg. #300 North Blvd. Bldg. #200 Main Blvd. Bldg. #100 South Blvd. Group B- Tuesday, Thursday and Sunday #4- 12am to 2am @180 gpm Bldg. #225 North Blvd. Bldg. #125 Main Blvd. Bldg. #90 South Blvd. #5- 2am to 4am @180 gpm Bldg.#215 North Blvd. Bldg. #115 Main Blvd. Bldg. #95 North Blvd. #6- 4am to 6am @180 gpm Bldg. #205 Main Blvd. Bldg. # 105 South Blvd. Bldg. #97 North Blvd. L FL _,�� 112013 CORRECTED p L COPY REVISIONS I BY Sheets Of 2, Sheets