DRAWINGS0 8 Device Number of Devices Current per Device Standby Current Alarm Current For each device use t1rr"s Th IS ColumntColumnx formula: Tins Oolurnn = Current per number of devices 5104 1 Standby: 75 mA 75 mA BY OTHERS Alarm: 135 mA 135 MA 5230 3 max Standby: 25 mA 25 mA RADIO COMMUNICATOR Alarm: SID mA 40 mA 51046/5230 Current Subtotals: 1 100 mAj 175 mA Smoke Detectors SURGE PROTECTION - 110VAC DITECK ED LV 2W3 (SMOKE DET) 1 Standby: .05 mA .05 mA Alarm: 130 mA 130 MA Q Standby: mA mA .,.1 Alarm: mA mA J > Standby: mA mA Alarm: mA mA LL Standby_ mA mA Alarm: mA mA Standby: mA mA CLW Alarm., mA mA z Q m Standby: mA mA Alarm: mA mA, Current Subtotals: .05 mA 130 mA Notification Appliances MB -GS -12-R (BELL.) Alarrn: 100 mA F_ 100 mA 0 mA 3 Z mA < rnA ICL mA Current Subtotals: 100 mA Total current rating of all devices in system (add totals of A -C) x .001: .100 A .405 A Number of standby hours. (24 or 60 for NFPA 72, chapter 1, '1-5-2-5): 24 H Multiply lines D (standby current) and E. Total standby AH 24 AH Alarm sounding period in hours. (For example, 5 minutes = .0833 hours) .0$33 1-1 Multiply lines D (alarm Current) and G totals Total alarm AH .034 AH Add lines F and H. AH = Ampere Hours Total AH required 2.43 AH (D 7 AHR PROVIDED SEQUENCE OF OPERATION: 1. ACTIVATION OF SMOKE DETECTOR SHALL: A. ANNUNCIATE AT ALARM CONTROL PANEL AS A ZONE SMOKE ALARM. B. SOUND LOCAL BELL UNTIL SYSTEM IS SILENCED OR RESET. C. TRANSMIT A ZONE ALARM SIGNAL TO A CENTRAL STATION. 2. ACTIVATION OF WATERFLOW SWITCH SHALL: A. ANNUNCIATE AT ALARM CONTROL PANEL AS A ZONE WATERFLOW ALARM. B. SOUND LOCAL BELL UNTIL SYSTEM IS RESET (NON SILENCEABLE) C. TRANSMIT A ZONE WATERFLOW SIGNAL TO A CENTRAL STATION. 3. ACTIVATION OF A SPRINKLER SUPERVISORY VALVE TAMPER SHALL: A. ANNUNCIATE AT THE ALARM CONTROL PANEL AS A ZONE SUPERVISORY SIGNAL. B. TRANSMIT A ZONE SUPERVISORY SIGNAL TO A CENTRAL STATION. C. SYSTEM SHALL RESTORE UPON TURNING VALVE BACK TO NORMAL POSITION. 4. ABNORMAL CONDITIONS SHALL: A. ANNUNCIATE AT THE ALARM CONTROL PANEL AS AN TROUBLE SIGNAL. B. TRANSMIT A TROUBLE SIGNAL TO A CENTRAL STATION. C. SYSTEM SHALL REMAIN IN TROUBLE CONDITION UNTIL ABNORMAL CONDITION IS RESTORED TO NORMAL CONDITION. SCOPE OF WORK: SYMBOL PART # DESCRIPTION MANUFACTURE MB P 2WB SMOKE DETECTOR SYSTEM SENSOR �A.A'�TCJI YAYL9 YR-ih4 MS -G6 -12R WATERFLOW BELL 6" WHEELOCK WATERFLOW SWITCH BY OTHERS SUPERVISORY VALVE TAMPER BY OTHERS TG -7 TG -7 RADIO COMMUNICATOR TELGUARD 51048 51046/5230 ALARM CONTROL PANEL W/ KEYPAD SILENT KNIGHT El HV 120HW SURGE PROTECTION - 110VAC DITECK ED LV 2MHLP24BW SURGE PROTECTION - LOW VOLTAGE DITECK to 1. INSTALL NEW LOW VOLTAGE, POWER LIMITED, UL LISTED FOR FIRE ALARM USE FIRE ALARM COMMUNICATOR TO MONITOR FIRE SPRINKLER WATERFLOW AND BACKFLOW TAMPER. 2. SYSTEM SHALL BE INSTALLED PER NFPA-72 (2007), NEC ARTICAL 760, NFPA-101, STATE FIRE MARSHALES RULES AND MANUFACTURES SPECIFICATIONS. 3. BUILDING IS EXISTING AND SPRINKLED. BUILDING DOES NOT HAVE AN EXISTING FIRE ALARM SYSTEM. SPRINKLER COMMUNICATOR FLOOR PLAN !� �l ZONE 2 NAC -1 FE-OLI EO .131 0, WP 1812 FPL CABLE W1 ZONE 3 EOL S RISER LV Q ZONE 4 EOL ZONE 5 EOL 1812 FPL CABLE 1812 FPL CABLE 5104E 5230 CONTROL PANEL J HV H, N, G 120 VAC DEDICATED BRANCH CIRCUIT WITH BREAKER LOCK ON HOUSE "EM" PANEL TG -7 RADIO COMMUNICATOR CONTROL PANEL SPRINKLER COMMUNICATOR RISER PLAN N.T.S. IMNN BY Structural Electrical Plumbing Mechanical �Z :Forester Fire F�o ice 61,71her Or= All work irvoiced c 'his permi4 shall conform with all City . $ :9 - - - �rr� �: c,Ra�;lioi^€ Beach 13�i;di;g Codes baapjC,,Ab!�:� RKS' l , "V 7eb, WI` l 4 MAR ® 29 BUILDING 2 LOCATION Re;rn O m !f {r '{ - fivSTtiLt` i �A.A'�TCJI YAYL9 YR-ih4 - 3-3-14 REVISIONS AHJ - REMOVE BACKFLOW TAMPERS 1 TO BE CHAINED - 3-3-14 V .1 ..J 1.1.1 to Q � .,.1 M J > > m LL n � Q V CLW LLI z Q m 0 0 O z F_ = 0 m 3 Z W < ICL W z W 0 .-J C a (D I:zr CD M �- C►- 4— {Q ' _,.,.1 �- LL J� s ' c) co pyg S- W I O C:) r 0 Ot� LO 0 LLL N Cil LLI O UL O U z 0 SHEET FA -1 OF 1 DATE: 12-30-13 SCALE: 1/8" = 11-0i, DRAWN BY: LSM CHECKED Y: LSM Q IN C D E F G I Device Number of Devices Current per Crevice Standby Current Alarm Current For each device use this formula: This Column X Column = Current per number of devices 5104 i Standby: 75 mA 75 mA BY OTHERS Alarm: 135 mA 135 mA 5230 3 max Standby: 25 mA 25 mA RADIO COMMUNICATOR Alarm: 40 mA 40 mA 5104615230 Current Subtotals: 100 mA 176 MA Smoke Detectors SURGE PROTECTION - 110VAC DITECK EflLV 2WB (SMOKE DET) Standby: .05 mA .05 mA cF{y of Boynton Beach B Alarm: 130 mA 130 mA Standby: mA mA Alarm, mA mA to Standby: mA mA Alarm: mA mA Standby: mA mA Alarm: mA mA` Standby: mA mA Alarm: mA mA Standby: mA mA Alarm: mA rnA Current Subtotals: ,05 mA 130 mA Notification Appliances M13 -G6 -12-R (BELL) { Alarm: 100 mA 100 mA' z Q m rnA �: z mA Q mA � rnA Current Subtotals: 100 mA Total current rating of all devices in system (acid totals of A -C) x .001: .100 A .405; A Number of standby hours. (24 or 60 for NFPA 72, chapter 1, 1-5.2.5): 24 H 0 Nilultiply lines D (standby current) and E_ Total standby AH 2.4 AH Alarm sounding period in hours_ (For example, 5 minutes = -0833 hours) z .0833 H Nluttiply lines D (alarm Current) and G totals Total alarm AH Q .034 AH Add lines F and H. AH = Ampere Hours Total AH required 2,43 AH 7 AHR PROVIDED SEQUENCE OF OPERATION: I. ACTIVATION OF SMOKE DETECTOR SHALL: A. ANNUNCIATE AT ALARM CONTROL PANEL AS A ZONE SMOKE ALARM. B. SOUND LOCAL BELL UNTIL SYSTEM IS SILENCED OR RESET. C. TRANSMIT A ZONE ALARM SIGNAL TO A CENTRAL STATION. 2. ACTIVATION OF WATERFLOW SWITCH SHALL: A_ ANNUNCIATE AT ALARM CONTROL PANEL AS A ZONE WATERFLOW ALARM. B. SOUND LOCAL BELL UNTIL SYSTEM IS RESET (NON SILENCEABLE) C. TRANSMIT A ZONE WATERFLOW SIGNAL TO A CENTRAL STATION. 3. ACTIVATION OF A SPRINKLER SUPERVISORY VALVE TAMPER SHALL: A. ANNUNCIATE AT THE ALARM CONTROL PANEL AS A ZONE SUPERVISORY SIGNAL. B. TRANSMIT A ZONE SUPERVISORY SIGNAL TO A CENTRAL STATION. C. SYSTEM SHALL RESTORE UPON TURNING VALVE BACK TO NORMAL POSITION. 4. ABNORMAL CONDITIONS SHALL: A. ANNUNCIATE AT THE ALARM CONTROL PANEL AS AN TROUBLE SIGNAL. B. TRANSMIT A TROUBLE SIGNAL TO A CENTRAL STATION. C. SYSTEM SHALL REMAIN IN TROUBLE CONDITION UNTIL ABNORMAL CONDITION IS RESTORED TO NORMAL CONDITION. SCOPE OF WORK: SYMBOL PART # DESCRIPTION MANUFACTURE M°° P 2WB SMOKE DETECTOR SYSTEM SENSOR �j uu MB -G6 -12R WATERFLOW BELL 6" WHEELOCK viechanical WATERFLOW SWITCH BY OTHERS i l3&z SUPERVISORY VALVE TAMPER BY OTHERS TG -7 TG -7 RADIO COMMUNICATOR TELGUARD 5104E 5104615230 ALARM CONTROL PANEL Wl KEYPAD SILENT KNIGHT E HV 120HW SURGE PROTECTION - 110VAC DITECK EflLV 2MHLP248W SURGE PROTECTION - LOW VOLTAGE DITECK cF{y of Boynton Beach B 0a yes J 1. INSTALL NEW LOW VOLTAGE, POWER LIMITED, UL LISTED FOR FIRE ALARM USE FIRE ALARM COMMUNICATOR TO MONITOR FIRE SPRINKLER WATERFLOW AND BACKFLOW TAMPER. 2. SYSTEM SHALL BE INSTALLED PER NFPA-72 (2007), NEC ARTICAL 760, NFPA-101, STATE FIRE MARSHALES RULES AND MANUFACTURES SPECIFICATIONS. 3. BUILDING IS EXISTING AND SPRINKLED. BUILDING DOES NOT HAVE AN EXISTING FIRE ALARM SYSTEM. T1 T2 YA � BACKFLOW SPRINKLER COMMUNICATOR FLOOR PLAN 4"��OWN) ZONE 3 ZONE 4 ZONE 2 01 1812 FPL CABLE W1 a104B RISER LV NAC -1 EOL WP 1812 FPL {CABLE TG -7 T2 T1 S 5230 LV BACKFLOW T3 ,CONTROL PANEL ZONES EOL RISER S HV 1812 FPL CABLE H,N,G 120 VAC DEDICATED BRANCH CIRCUIT WITH BREAKER LOCK ON MOUSE "EM" PANEL RADIO COMMUNICATOR CONTROL PANEL SPRINKLER COMMUNICATOR RISER PLAN N.T.S. structural BUILDING 2 LOCATION REVISIONS Electrical 7- 1 ��tt )ppc a,e1 ED' Piumbing viechanical OUN i l3&z sx. yet 0114 Forester Fire ,T"Y Police Ii+ tither "IJ FIA. Processed by' s Arl vvfi3R 3nVi33C2'3 on {:i1S t32iEI'if 5� I conform W4Yh 31i cF{y of Boynton Beach B 0a yes BUILDING 2 LOCATION REVISIONS J J W to ,JAM i G aid z Q m �: z Q � 0 r 0 W z © Q � W Z 0 W c v (b? a+ 00 LO V) �- > (Y') �- _ (y) R3 U- R, OY�Xa c® CD CL ` a ' O s— CO 0') CD L0 (z1 GD U i O LL - 0 0 U SHEET FA -1 OF 1 TE: 12-30-13 ' SCALE: 1/8" = 17—Off DA BY: LSM CHECKED BY: LSM