DRAWINGS1. PROVIDE & INSTALL A FORCED AIR SYSTEM INCLUDING, BUT NOT LIMITED TO AIR HANDLING UNIT, A/C COMPRESSOR, DUCTWORK AND AIR OUTLETS AS SHOWN
ON THE DRAWINGS AND AS SPECIFIED.
2. MECHANICAL EQUIPMENT & FITTINGS SHALL BE PROVIDED AS SHOWN ON THE DRAWINGS. WORK SHALL INCLUDE TRIM AND RELATED CONSTRUCTION AS
REQUIRED.
3. PROVIDE EXPERIENCED, WELL TRAINED WORKERS COMPETENT TO COMPLETE THE WORK AS SPECIFIED.
4. UNLESS APPROVED BY THE DESIGNER, PROVIDE RELATED PRODUCTS AND ACCESSORIES FROM ONE MANUFACTURER.
5. ALL WORK SHALL COMPLY W/ MANUFACTURER'S SPECIFICATIONS.
6. SUB -CONTRACTOR SHALL PROVIDE COPIES OF MANUFACTURERS INSTALLATION, MAINTENANCE & WARRANTY INFORMATION.
7. DELIVER, STORE & TRANSPORT MATERIALS TO AVOID DAMAGE TO THE PRODUCT AND OTHER WORK. REJECT ANY DAMAGED PRODUCTS DELIVERED TO JOB SITE.
8. VERIFY LAYOUT AND C.F.M. REQUIREMENTS SHOWN ON DRAWINGS AND NOTIFY DESIGNER OF DISCREPANCIES.
9. EXAMINE AND VERIFY THAT JOB CONDITIONS ARE SATISFACTORY FOR ACCEPTABLE WORK.
10. MAINTAIN AND USE UP-TO-DATE TRADE STANDARDS AND MANUFACTURER'S INSTRUCTIONS.
11. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES.
12. DUCTWORK SHALL BE R-6 MINIMUM (3 POUNDS PER CUBIC FOOT DENSITY FIBERGLASS WITH VAPOR BARRIER) IN ACCORDANCE WITH ASHRAE AND SMACNA
STANDARDS. DUCTWORK AND COMPONENTS SHALL BE CLASS 1 IN ACCORDANCE WITH 181 TESTS.
13. FLEXIBLE DUCT SHALL BE CLASS A IN ACCORDANCE WITH NAFPA STANDARDS 90A OR 90B INSTALLED STRICTLY AS DIRECTED BY MANUFACTURER, WITHOUT SAGS
OR KINKS.
14. REFRIGERANT PIPING SHALL BE COPPER, HAND DRAWN TYPE L ACR TYP, DEHYDRATED AND SEALED JOINTS TO BE HIGH TEMPERATURE BRAZING ALLOY NOT LESS
THAN 5% SILVER. INSULATION NOT LESS THAN 1/2" "ARMAFLEX" TYPE. LIQUID AND SUCTION LINES TO BE SIZED ACCORDING TO MANUFACTURER'S SPECIFICATIONS.
15. PROVIDE TURNING VANES FOR PROPER AIR BALANCING.
16. PROVIDE GASKETS AT ALL GRILLS AND DIFFUSERS.
17. DRYER VENT SHALL BE MIN. 25 GAUGE METAL PIPE WITH SMOOTH INTERIOR SURFACE OR APPROVED METAL MATERIAL AND INSTALLED AND UTILIZED IN
ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. MINIMUM SIZE OF EXHAUST DUCT SHALL BE 4" INTERIOR DIMENSIONS. MAXIMUM LENGTH SHALL NOT
EXCEED 25' FROM DRYER LOCATION TO WALL, ROOFCAP OR ENGINEERED EXHAUST SYSTEM.
18. BALANCED AIR RETURN - RETURN AIR SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL AREA (SQ INCHES) OF THE SUPPLY DUCT ENTERING THE ROOM ITS SERVING &
THE DOOR HAVING UNRESTRICTED 1" UNDERCUT. ALL SUPPLY AIR INTO THE MASTER SUITE SHALL BE INCLUDED.
19. SIZING FOR THRU THE WALL TRANSFER GRILLES SHALL USE 50 SQUARE INCHES TO 100 CFM OF SUPPLY AIR WITH UNRESTRICTED 1" DOOR UNDERCUT.
20. DUCTS SHALL NOT BE INSTALLED IN OR WITHIN 6" OF THE GROUND.
21. DRYER VENT -MIN. 4" GALVANIZED
METAL DUCT TO BE LISTED AND UL LABEL AND CONSTRUCTED AS PER FMC 504.6 AND VENTED TO THE EXTERIOR WITH BACK DRAFT DAMPER AS 504.4&5
22. AC SHALL BE IN COMPLIANCE WITH 2010 FMC AND PBC ADMENDMENTS
23. AHU UNITS SHALL HAVE A DRAIN PAN WITH OVERFLOW SHUT OFF SWITCH
FIRST FLOOR HVAC PLAN
Scale: 1/4" = 1'-0"
GENERAL HVAC NOTES
19
2
CORRECTE!)"s COPY
K.O. ENERGY
DESIGN, LLC
erf idency by design
1470 NORTH CONGRESS AVE
WEST PALM BEACH, FL, 33409
561.327.7272 FAX 561.333.0775
FLORIDA STATE LICENSE #CACA15692
DRAWINGS FOR:
THE
SANDERS
RESIDENCE
2001 NW 2nd STREET
BOYNTON BEACH, FLORIDA
DRAWING INFO
DATE 4/14/2014
SCALE VARIES
JOB # xxxx
DRAWN BY D. MOYER
REVISIONS
OWNERSHIP AND USE OF
THESE DOCUMENTS &
SPECIFICATIONS AS
INSTRUMENTS OF SERVICE ARE
AND SHALL REMAIN THE
PROPERTY OF THE K.O. ENERGY
DESIGN, LLC. WHETHER THE
PROJECT THEY ARE MADE FOR
IS EXECUTED OR NOT. THEY
SHALL NOT BE USED BY THE
OWNER OR OTHERS ON OTHER
PROJECTS OR FOR ADDITIONS
TO THIS PROJECT BY OTHERS,
EXCEPT BY AGREEMENT IN
WRITING FROM K.O. ENERGY
DESIGN, LLC.
SHEET
M.1