DRAWINGS1. PROVIDE & INSTALL A FORCED AIR SYSTEM INCLUDING, BUT NOT LIMITED TO AIR HANDLING UNIT, A/C COMPRESSOR, DUCTWORK AND AIR OUTLETS AS SHOWN ON THE DRAWINGS AND AS SPECIFIED. 2. MECHANICAL EQUIPMENT & FITTINGS SHALL BE PROVIDED AS SHOWN ON THE DRAWINGS. WORK SHALL INCLUDE TRIM AND RELATED CONSTRUCTION AS REQUIRED. 3. PROVIDE EXPERIENCED, WELL TRAINED WORKERS COMPETENT TO COMPLETE THE WORK AS SPECIFIED. 4. UNLESS APPROVED BY THE DESIGNER, PROVIDE RELATED PRODUCTS AND ACCESSORIES FROM ONE MANUFACTURER. 5. ALL WORK SHALL COMPLY W/ MANUFACTURER'S SPECIFICATIONS. 6. SUB -CONTRACTOR SHALL PROVIDE COPIES OF MANUFACTURERS INSTALLATION, MAINTENANCE & WARRANTY INFORMATION. 7. DELIVER, STORE & TRANSPORT MATERIALS TO AVOID DAMAGE TO THE PRODUCT AND OTHER WORK. REJECT ANY DAMAGED PRODUCTS DELIVERED TO JOB SITE. 8. VERIFY LAYOUT AND C.F.M. REQUIREMENTS SHOWN ON DRAWINGS AND NOTIFY DESIGNER OF DISCREPANCIES. 9. EXAMINE AND VERIFY THAT JOB CONDITIONS ARE SATISFACTORY FOR ACCEPTABLE WORK. 10. MAINTAIN AND USE UP-TO-DATE TRADE STANDARDS AND MANUFACTURER'S INSTRUCTIONS. 11. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES. 12. DUCTWORK SHALL BE R-6 MINIMUM (3 POUNDS PER CUBIC FOOT DENSITY FIBERGLASS WITH VAPOR BARRIER) IN ACCORDANCE WITH ASHRAE AND SMACNA STANDARDS. DUCTWORK AND COMPONENTS SHALL BE CLASS 1 IN ACCORDANCE WITH 181 TESTS. 13. FLEXIBLE DUCT SHALL BE CLASS A IN ACCORDANCE WITH NAFPA STANDARDS 90A OR 90B INSTALLED STRICTLY AS DIRECTED BY MANUFACTURER, WITHOUT SAGS OR KINKS. 14. REFRIGERANT PIPING SHALL BE COPPER, HAND DRAWN TYPE L ACR TYP, DEHYDRATED AND SEALED JOINTS TO BE HIGH TEMPERATURE BRAZING ALLOY NOT LESS THAN 5% SILVER. INSULATION NOT LESS THAN 1/2" "ARMAFLEX" TYPE. LIQUID AND SUCTION LINES TO BE SIZED ACCORDING TO MANUFACTURER'S SPECIFICATIONS. 15. PROVIDE TURNING VANES FOR PROPER AIR BALANCING. 16. PROVIDE GASKETS AT ALL GRILLS AND DIFFUSERS. 17. DRYER VENT SHALL BE MIN. 25 GAUGE METAL PIPE WITH SMOOTH INTERIOR SURFACE OR APPROVED METAL MATERIAL AND INSTALLED AND UTILIZED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. MINIMUM SIZE OF EXHAUST DUCT SHALL BE 4" INTERIOR DIMENSIONS. MAXIMUM LENGTH SHALL NOT EXCEED 25' FROM DRYER LOCATION TO WALL, ROOFCAP OR ENGINEERED EXHAUST SYSTEM. 18. BALANCED AIR RETURN - RETURN AIR SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL AREA (SQ INCHES) OF THE SUPPLY DUCT ENTERING THE ROOM ITS SERVING & THE DOOR HAVING UNRESTRICTED 1" UNDERCUT. ALL SUPPLY AIR INTO THE MASTER SUITE SHALL BE INCLUDED. 19. SIZING FOR THRU THE WALL TRANSFER GRILLES SHALL USE 50 SQUARE INCHES TO 100 CFM OF SUPPLY AIR WITH UNRESTRICTED 1" DOOR UNDERCUT. 20. DUCTS SHALL NOT BE INSTALLED IN OR WITHIN 6" OF THE GROUND. 21. DRYER VENT -MIN. 4" GALVANIZED METAL DUCT TO BE LISTED AND UL LABEL AND CONSTRUCTED AS PER FMC 504.6 AND VENTED TO THE EXTERIOR WITH BACK DRAFT DAMPER AS 504.4&5 22. AC SHALL BE IN COMPLIANCE WITH 2010 FMC AND PBC ADMENDMENTS 23. AHU UNITS SHALL HAVE A DRAIN PAN WITH OVERFLOW SHUT OFF SWITCH FIRST FLOOR HVAC PLAN Scale: 1/4" = 1'-0" GENERAL HVAC NOTES 19 2 CORRECTE!)­"s COPY K.O. ENERGY DESIGN, LLC erf idency by design 1470 NORTH CONGRESS AVE WEST PALM BEACH, FL, 33409 561.327.7272 FAX 561.333.0775 FLORIDA STATE LICENSE #CACA15692 DRAWINGS FOR: THE SANDERS RESIDENCE 2001 NW 2nd STREET BOYNTON BEACH, FLORIDA DRAWING INFO DATE 4/14/2014 SCALE VARIES JOB # xxxx DRAWN BY D. MOYER REVISIONS OWNERSHIP AND USE OF THESE DOCUMENTS & SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE PROPERTY OF THE K.O. ENERGY DESIGN, LLC. WHETHER THE PROJECT THEY ARE MADE FOR IS EXECUTED OR NOT. THEY SHALL NOT BE USED BY THE OWNER OR OTHERS ON OTHER PROJECTS OR FOR ADDITIONS TO THIS PROJECT BY OTHERS, EXCEPT BY AGREEMENT IN WRITING FROM K.O. ENERGY DESIGN, LLC. SHEET M.1