DRAWINGSALL MATERIAL APPLICABLE TO THIS PROJECT WILL BE INDICATED WITH A (Q� ) ❑ ALL PLASTIC PIPE 3/4" THROUGH 2YE" SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F-442. ❑ ALL PLASTIC FITTINGS SHALL BE UL LISTED OR FM APPROVED CPVC MANUFACTURED IN ACCORDANCE WITH ASTM F438, ASTM F439 OR ASTM F1970. ALL CPVC PIPE AND FITTINGS SHALL BE ASSEMBLED USING 'ONE STEP' 500 CEMENT. ❑ CPVC PIPE SHALL BE ALLOWED TO BE USED IN ORDINARY HAZARD ROOMS OF 400 SQUARE FEET OR LESS OF OTHERWISE LIGHT HAZARD OCCUPANCIES (NFPA 13 SECTION 6.3.6.2 OR NFPA 13R SECTION 5.2.2.3). F-� ALL 1" TO 2" THREADED BLACK STEEL PIPE SHALL BE UL LISTED/FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-135 OR A-795. ACCEPTABLE PIPE BRANDS ARE WHEATLAND 'MEGATHREAD', ALLIED 'DYNATHREAD', BULL MOOSE TUBE 'EDDYTHREAD' AND WELDED TUBE -BERKELEY 'STEADY -THREAD'. ALL PIPE SHALL BE CPVC COMPATIBLE. ALL 1' TO 2" THREADED GALVANIZED PIPE WILL BE SCHEDULE 40 HOT DIPPED GALVANIZED MANUFACTURED IN ACCORDANCE WITH ASTM A-795 OR ASTM A-53. ALL 1' TO 2" THREADED BLACK STEEL PIPE SHALL BE SCHEDULE 40 UL LISTED/FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-795. ACCEPTABLE PIPE MANUFACTURERS ARE WHEATLAND, ALLIED, BULL MOOSE TUBE AND WELDED TUBE -BERKELEY. ALL PIPE SHALL BE CPVC COMPATIBLE. ❑ ALL 11'4" TO 4" GROOVED BLACK STEEL PIPE SHALL BE UL LISTED/FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A795. ACCEPTABLE BRANDS ARE BULL MOOSE 'EDDYFLOW', WHEATLAND 'MEGA -FLOW', ALLIED 'DYNA-FLOW' AND WELDED TUBE -BERKELEY 'STEADY -FLOW'. ALL PIPE SHALL BE CPVC COMPATIBLE. ALL IY4" TO 4" GROOVED BLACK STEEL PIPE SHALL BE SCHEDULE 10, UL LISTED/FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-795. ACCEPTABLE MANUFACTURERS ARE BULL MOOSE, WHEATLAND, ALLIED AND WELDED TUBE -BERKELEY. ALL PIPE SHALL BE CPVC COMPATIBLE. ALL GROOVED STEEL PIPE 6" AND LARGER SHALL BE UL LISTED/FM APPROVED SCHEDULE 10 AND MANUFACTURED IN ACCORDANCE WITH ASTM A-135. ❑ ALL GROOVED STEEL PIPE IY4" AND LARGER SHALL BE SCHEDULE 10 HOT DIPPED GALVANIZED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-795. ALL STEEL PIPE SHALL HAVE A CORROSION RESISTANCE RATIO (CRR) OF NOT LESS THAN 1.0 PER WAFS STANDARDS. ALL BLACK THREADED FITTINGS SHALL BE DUCTILE IRON CLASS 150 OR CLASS 300 ANSI B15.3, CAST IRON CLASS 125 OR CLASS 250 ANSI BIBA OR MALLEABLE IRON CLASS 150 OR CLASS 300 ANSI 616.3. F-] ALL GALVANIZED THREADED FITTINGS SHALL BE MALLEABLE IRON CLASS 150 OR CLASS 300 ANSI 816.3 WITH GALVANIZED COATING IN ACCORDANCE WITH ASTM A-153. F-1 ALL WELDED OUTLETS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ANSI B16.11. F-] GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. ❑ ALL GALVANIZED GROOVED FITTINGS SHALL BE UL LISTED OR FM APPROVED AND MANUFACTURED IN ACCORDANCE WITH ASTM A-536 FOR DUCTILE IRON OR ASTM A-47 FOR MALLEABLE IRON. GALVANIZED COATING SHALL BE IN ACCORDANCE WITH ASTM A-153. ALL GROOVED STEEL PIPE SHALL BE ROLL GROOVED PER PIPE MANUFACTURER REQUIREMENTS. PIPE AND FMI46.S SAL RTES SCALE, NONE Rr. Bpr0 No Ino, WAFS POLICY ON REUSING SPRINKLERS NFPA 13 STATES THAT ONLY NEW SPRINKLERS SHALL BE INSTALLED, WAFS POLICY IS TO REPLACE ANY SPRINKLER THAT HAS BEEN REMOVED FROM THE FITTING TO WHICH IT WAS ATTACHED, IF DURING THE COURSE OF SERVICE OR REPAIR TO THE FIRE SPRINKLER SYSTEM THE SPRINKLER REMAINS IN THE FITTING TO WHICH IT WAS INSTALLED AND THE SPRINKLER IS PROTECTED FROM DAMAGE THROUGHOUT THE ADJUSTMENT PROCESS, THAT SPRINKLER MAY REMAIN, HANGER INSTALLATION NOTES 1. ONE HANGER FOR EACH SECTION OF PIPE. 1.1. WHERE SPRINKLERS ARE SPACED LESS THAN 6' APART, HANGERS SPACED UP TO A MAXIMUM OF 12' SHALL BE PERMITTED. 1.2. STARTER LENGTHS LESS THAN 6' SHALL NOT REQUIRE A HANGER, UNLESS ON THE END LINES OF A SIDEFEED SYSTEM OR WHERE AN INTERMEDIATE CROSS MAIN HANGER HAS BEEN OMITTED. 2. CLEARANCE BETWEEN A HANGER AND THE CENTERLINE OF AN UPRIGHT SPRINKLER SHALL NOT .BE LESS THAN 3". 3. THE UNSUPPORTED LENGTH BETWEEN THE END SPRINKLER AND THE LAST HANGER ON THE LINE SHALL NOT BE GREATER THAN 35" FOR 1 -IN. PIPE, 48" FOR 1 -IN. PIPE, AND 60" FOR 1 -IN. OR LARGER PIPE. WHERE THESE LIMITS ARE EXCEEDED, THE PIPE SHALL BE EXTENDED BEYOND THE END SPRINKLER AND SHALL BE SUPPORTED BY AN ADDITIONAL HANGER. 4. ARM -OVERS SHALL HAVE A HANGER WHEN THE CUMULATIVE HORIZONTAL PIPE IS MORE THAN 24". USE A TRAPEZE HANGER WHEN NECESSARY. S. MAX HANGER SPACING: 5.1. STEEL PIPE: 1" - 1-1/4" (121, 1-1/2" - 4" (16) 5.2. THREADED LIGHTWALL: 1" - 3" (121 SEE NOTE 1.2 SEE NOTE 3 70TE 4 v -� v SEE NOTE 5 SEE NOTE 1.1 STEEL PIPE HANGER SPACING PRESSURE UNDER 1OOPS1 SCALD NONE Automtic Fire SprWere, km Il..:l: • DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH 2010 EDITION OF NFPA 13. 1r DESIGN AND INSTALLATION TO BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODES. • ALL PIPE AND FITTINGS USED ON THIS PROJECT TO BE IN ACCORDANCE WITH APPLICABLE CODES AND WAFS STANDARDS. SEE PIPE AND FITTINGS GENERAL NOTES (WAFS DETAIL #00593N). • ALL HANGERS AND ANY REQUIRED BRACING SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 13, MANUFACTURER'S INSTRUCTIONS AND THEIR LISTING. • ALL PENETRATIONS THROUGH RATED BUILDING ASSEMBLIES SHALL BE SEALED WITH FIRE CAULK IN ACCORDANCE WITH DETAILS PROVIDED. WAFS POLICY IS TO USE HILTI FS ONE OR STI LCL • UNDERGROUND MAINS AND LEAD-INS SHALL BE FLUSHED AND SIGNED TEST CERTIFICATES PROVIDED BEFORE A CONNECTION IS MADE TO THE SYSTEM. r ALL PIPING SHALL BE INSPECTED AND APPROVED BY PROPER AUTHORITIES PRIOR TO COVERING WITH DRYWALL. COPIES OF SIGNED TEST CERTIFICATES ARE TO BE FORWARDED TO THE PROPER RECIPIENTS. • ALL SYSTEMS SHALL BE TESTED FOR 2 HOURS AT 200 PSI OR 50 PSI GREATER THAN MAXIMUM SYSTEM WORKING PRESSURE, WHICHEVER IS GREATER. • ALL SOFFITS REQUIRED TO CONCEAL SPRINKLER PIPING ARE BY OTHERS. • ALL WIRING OF DEVICES (FLOW SWITCHES, TAMPER SWITCHES, COMPRESSORS, ETC) IS BY OTHERS. • CONNECTION OF SPRINKLER DEVICES TO THE BUILDING ALARM OR MONITORING SYSTEM IS BY OTHERS. • ALL PAINTING OF PIPE AS REQUIRED IS BY OTHERS. (r ALL INSULATION REQUIRED FOR FREEZE PROTECTION OF SPRINKLER SYSTEM IS BY OTHERS. • HEATING OF ROOMS TO MAINTAIN TEMPERATURES OF 40 DEGREES OR GREATER IS BY OTHERS. 8 FIRE DEPARTMENT CONNECTIONS SHALL BE LOCATED NOT LESS THAN IB" AND NOT MORE THAN 46" ABOVE THE LEVEL OF THE ADJACENT GRADE. • QUICK RESPONSE SPRINKLERS SHALL BE USED IN ALL LIGHT HAZARD AREAS. • SPARE SPRINKLERS OF EACH TYPE (EXCLUDING DRY) SHALL BE PROVIDED ON THE PREMISES AS FOLLOWS: o LESS THAN 300 - 6 SPRINKLERS 0 300 TO 1000 - 12 SPRINKLERS o OVER 1000 - 24 SPRINKLERS • REFER TO SPACING NOTES ON PLANS FOR MAXIMUM CALCULATED SPACING ALLOWANCES. 4, SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT AS FOLLOWS: o ANY PORCHES, BALCONIES OR OVERHANGS THAT ARE NON-COMBUSTIBLE AND ARE NOT USED FOR STORAGE. o CORRIDORS THAT ARE NON-COMBUSTIBLE IN CONSTRUCTION AND AT LEAST 509 OPEN. o AT THE TOP OF ALL ELEVATOR SHAFTS WHERE THE CAR ENCLOSURE MEETS THE REQUIREMENTS OF ASME A17.1. o AT THE BOTTOM OF ENCLOSED NON COMBUSTIBLE ELEVATOR SHAFTS THAT DO NOT CONTAIN COMBUSTIBLE HYDRAULIC FLUID. • WAFS TO PROVIDE ALL REQUIRED SIGNAGE PER NFPA 13 INCLUDING BUT NOT LIMITED TO VALVES, HYDRAULIC PLACARDS, AND INSPECTION TAGS AS REQUIRED BY FS 633. NFPA 13 20110 SAL NOTES SCALE, NONE P" sp rlkl.r., km 00859N 00686N CEILING TYPICAL STANDARD SPRAY PENDENT SPRINKLER TYPICAL STANDARD SPRAY UPRIGHT SPRINKLER B�- - A ----- TYPICAL OBSTRUCTION CEILING TYPICAL OBSTRUCTION DISTANCE FROM SPRINKLER TO SIDE OF OBSTRUCTION (A) MAXIMUM ALLOWABLE DISTANCE OF DEFLECTOR ABOVE BOTTOM OF OBSTRUCTION (IN.) (B) LESS THAN 1 FT. 0 1 FT, TO LESS THAN 1 FT, 6 IN, Mercantile 1 FT, 6 IN, TO LESS THAN 2 FT, 3 2 FT, TO LESS THAN 2 FT. 6 IN, 5 2 FT, 6 IN, TO LESS THAN 3 FT, 7 3 FT, TO LESS THAN 3 FT, 6 IN, 9 3 FT, 6 IN, TO LESS THAN 4 FT, 12 4 FT, TO LESS THAN 4 FT, 6 IN, 14 4 FT, 6 IN, TO LESS THAN 5 FT, 16h 5 FT, AND GREATER 18 NFPA 13 TABLE 8,6,512 NFPA 13 SPRINKLER CLEARANCE W/ OBSTRUCTION (STANDARD SPRAY LIPRWT / STANDARD SPRAY PENDENT) SCALED NONE FMe Sprinkbre, hm. 00610N SPRINKLER HEAD FIRE SPRINKLER DETAILS DESIGN CRITERIA ALL PIPE TO BES ❑ SCH. 7 ❑ SCH, 30 ❑ GALV, ❑ SCH. 10 dSCH, 40 ❑ CPVC CLASSIFICATION; Mercantile HAZARD; Ordinary Hazard Group II MAX, HEAD COVERAGE: 130 SQ,FT, SCOPE OF WORK NUMBER OF RELOCATED SPRINKLER HEADS; 13 NUMBER OF ADDED SPRINKLER HEADSi 5 NUMBER OF PLUGGED SPRINKLER HEADS N ALL FIRE SPRINKLER SYSTEM MATERIALS (HEADS, PIPES AND HANGERS) ARE PERI ❑ NFPA 13 2002 EDITION ❑ NFPA 13 2007 EDITION If NFPA 13 2010 EDITION SCOPE OF WORK DETAILS/NOTES: Relocate (13), add (5) & plug (lU) fire sprinkler heads to accommodate tenant remodel shown per plan,, Owner will be removing all coolers and freezers. W,A,F,S, to remove dry pendents and replace w/ new uprights at deck level to assure proper sprinkler coverage, Only areas indicating fire sprinkler work will be in W,A,F,S scope of work, LEGEND EXISTING PIPE — — — — — NEW PIPE DOMESTIC DEMAND I - NEW HANGER Z MECHANICAL, TEE MT NEW SPRINKLER HEAD A* RELOCATED SPRINKLER HEAD R* PLUGGED EXISTING SPRINKLER HEAD -E NOT IN�SCOPE OF CONTRACT T— QUANTITY SPRINKLERS BW SPRINKLER HEAD C STEEL PIPE HANGER RING TABLE 3 - MAXIMUM SUPPORT SPACING NOM. PIPE SIZE A BA C 1' 3'-0' MAX. 12'-0' MAX, 3' MIN, lye 4'-0' MAX, 12'-0' MAX. 3' MIN, 1W TO 8' 5'-0' MAX. 15'-0' MAX, 3' MIN, WMAXIMUM SUPPORT SPACING FOR STEEL PIPE STEEL PIPE HALER SPACE 7WWARMW SCALE, NONE Firs Spr4ddere, Inc. C DESIGNER REFERENCE DETAIL VIEW - ALL THREAD ROD ' FOR -'TO4' WFOR 5'TO8' TOP BEAM CLAMP ` FOR 9/4' TO 4' PIPE ' FOR 5' TO 8' PIPE � mn�u, luny (SIZED TO PIPE) LOCKNUT (INCLUDED W/ CLAMP) HAND #01 RING HANGER FOR 3/47 TO B" PIPE (BAR .DIST) SCALE, NONE Fin Sp 0 dit bw 00198N NOTES= 1. ALL AREAS OUTSIDE OF SCOPE OF WORK IS NOT IN CONTRACT WITH WAYNE AUTOMATIC FIRE SPRINKLERS. 2. ENTIRE EXISTING BUILDING IS A FULLY SPRINKLER BUILDING. 3. HYDRAULIC CALCULATION IS NOT REQUIRED AS NEW DESIGN LAYOUT MATCHES EXISTING ORDINARY HAZARD II LAYOUT, CLASSIFICATION DOES NOT CHANGE. i 0 IMP4119 ORTANT OWNER INFORMATION THIS DRAWING IS BASED ON THE DWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THE APPLICABLE STANDARD FOR THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION SYSTEMS, PER SECTION 4,L THE RESPONSIBILITY FOR PROPERLY MAINTAINING A WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER. IF THE BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. TOTAL A/SI CPVC COMPATIBILITY NOTICE CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION RESISTANCE. OCCASIONALLY, HOWEVER CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS QED SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC. ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCOMPATIBLE.COM COPYRIGHT ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSE, OR ADAPTATION OF THE INFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND WILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. DATE, GRAPHICS ELEMENTS NOTE FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL, CIVIL, STRUCTURAL. OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK. REFER TO APPROVED ARCHITECTURAL, STRUCTURAL. MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE SPRINKLER \ DRAWINGS OR DETAILS WATER SUPPLY INFORMATION MUL9UH1 UR ACTUAL EXTRAPOLATED FIRE PUMP - STATIC PRESSURE SIZE, GPM E PSI - HYDRANT ELEV. - RESIDUAL PRESSURE DATE OF TEST- FLOV IN GPM - - TIME OF TEST - PITOT READING - MAW OF PORTS FLOWED - TEST PROVIDED BY -- OLE N it CONTRACT # DESIGN CRITERIA SYSTEM / DESIGN AREA # - HAZARD CLASS - # IF SPRINO.ERS IN DEM AREA - MINIMUM DENSITY - DESIGN AREA S.F. - PSI REQ'D 2 BR - GPM REQ'D 2 BR - PSI REQ'D @ TEST - GPM REQ'D 2 TEST - OIVATHN ! HDIEST SPRINKLER - HOSE INSIDE/OUTSIDE I - DOMESTIC DEMAND I - SPRINKLERS SPACING SYMBOL MAXIMUM MINIMUM COMMENTS I i T— QUANTITY SPRINKLERS SYMB. IST 2ND 3RD 4TH SIN SIZE K TEMP MODEL l ii i'. i i i �I i j - - - - TOTAL PER FLOOR - TOTAL THIS SHEET DATE SUBMITTALS By P I NO. DATE REVISIONS BY l XX/XX/XX -- - I� i WWAYNE- i! i! Automatic Fire Sprinklers, Inc. MAIN OFFICE — ORLANDO, FLORIDA EM CAPITOL COURT OCOM FLOMA 34761 PHONE (40" 866-3030 FAX: JACK80N4L= FL MES DISTRB)TION AVE WEST JACKSONVLFL WES8-2745 LE PHONE (804) 288-3030 FAX ()04) 288-0724 TAMPA, FL 3228 CHERRY PALM ORME TAMPA. FL 33816.9337 PHONE (82) 830 -OM3 FAX (90 63D-0312 POI, AM BEAAX PL 30 NW )S})( TERRACE POWAND BEACK FL 33084-,408 PHONE MA) W-3030 FAX (854) W-8424 FT MYEW FL 4883 LAHEDO AVE Fr. MYEM FL 33806-4924 PHONE (239) 433-3090 CONCOFD NC 4370 LMTDRSPORT DRVE CONCORD, NC 28027-8977 PHONE (704) 782-3032 STATE LICB� NC SPF&*aJR 28748 NC ALARM ROM SP LV ED SPFRAaR mg FAX (M) 433-328:1 FAX VO4) 796-8838 SC ALARM 3385 IhIED BY . --- Winn Dixie #259 620 S. Federal Hwy Boynton yon Beach, Florida 33435 Winn Dixie Maintenance 1141 SW 12th Ave - Pompano Beach, FL 33069 FEB 0' SHEET TITLE, I Notes & Details DRAWN BYI Michael Crawford TOTAL A/SI 18 DATE, 1/29/2015 AHJI City of Boynton Beach it CONTRACT # #9595 CENTER OF TILE JOB? [:] YES gffNO CENTER ON FIXTURES JOB? F_j YES aND j SHEET # FP1 CONSTRUCTION TYPE, IIB OCCUPANCY, M N c. �'•1•'G'• . AREA 01 SCALE: 1/8" 1 = -0 4' 2' 1' 0 8' 16' III SCALE 1/8' = 1' AREA 02 V-0)) SCALE: 1/8 VV • AL • 1*4ifil, AREA #3 / SCALE: 1/8" = 1'-0" 4' 2' 1' 0 8' 16' III i SCALE 1/8' = 1' Mal AND DRW TD PROVIDE PROPER R JL .I X mou co I� c BY S. FEDERAL HWY SITE PLAN V_V IMPORTANT OWNER INFORMATION THIS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THE APPLICABLE STANDARD FOR THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION SYSTEMS. PER SECTION 41 THE RESPONSIBILITY FOR PROPERLY MAINTAINING A WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER. IF THE BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. CPVC COMPATIBILITY NOTICE CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION RESISTANCE. OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS 00 SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC, ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCGMPATIBLE.COM COPYRIGHT ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSF, OR ADAPTATION OF THE INFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND VILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. GRAPHICS ELEMENTS NOTE FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL CIVIL, STRUCTURAL OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK, REFER TO APPROVED ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE SPRINKLER DRAWINGS OR DETAILS WATER SUPPLY INFORMATION • REQ! SIZEi GPM a PSI - /0' ` HYDRANT ELEV. - . Ia- 99.1-M.im .971F13 -11M, OF TEST_ IN GPM - - TIME OF TEST - �FLOW I PITOT READING - KMBOt OF PORTS FLOM - TEST PROVIDED BY -- PjEkOCATIUN ID • �. • SYSTEM / DESIGN AREA # - - - - HAZARD CLASS - # IF SPRINID.ERS IN DESIGNI AREA - MINIMUM DENSITY - 10 - -31 10 PSI REQ'D @ BR - GPM REQ'D E BR - PSI REQ'D 2 TEST - GPM REQ'D 2 TEST - SHATDN a HOEST SPRDJW - HOSE INSIDE/OUTSIDE - DOMESTIC DEMAND - alw ICOI TO K MOM it ]' PRE—FAB MEAT - p MEAT COOLER N c. �'•1•'G'• . AREA 01 SCALE: 1/8" 1 = -0 4' 2' 1' 0 8' 16' III SCALE 1/8' = 1' AREA 02 V-0)) SCALE: 1/8 VV • AL • 1*4ifil, AREA #3 / SCALE: 1/8" = 1'-0" 4' 2' 1' 0 8' 16' III i SCALE 1/8' = 1' Mal AND DRW TD PROVIDE PROPER R JL .I X mou co I� c BY S. FEDERAL HWY SITE PLAN V_V IMPORTANT OWNER INFORMATION THIS DRAWING IS BASED ON THE OWNER'S ACCEPTANCE OF THE CURRENTLY ADOPTED EDITION (EITHER STATE OR LOCAL) OF NFPA 25 AS THE APPLICABLE STANDARD FOR THE INSPECTION, TESTING AND MAINTENANCE OF WATER BASED FIRE PROTECTION SYSTEMS. PER SECTION 41 THE RESPONSIBILITY FOR PROPERLY MAINTAINING A WATER BASED FIRE PROTECTION SYSTEM SHALL BE THAT OF THE OWNER. IF THE BUILDING OWNER HAS NOT RECEIVED A COPY OF THIS PAMPHLET AND/OR IS NOT FAMILIAR WITH THE OPERATION AND MAINTENANCE OF THIS SYSTEM, PLEASE CONTACT THE NEAREST OFFICE OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. CPVC COMPATIBILITY NOTICE CPVC FIRE SPRINKLER PIPING SYSTEMS HAVE BEEN USED SUCCESSFULLY FOR MORE THAN 20 YEARS IN NEW CONSTRUCTION, RE -PIPE AND REPAIR. CPVC PRODUCTS ARE IDEALLY SUITED FOR THESE APPLICATIONS DUE TO THEIR OUTSTANDING CORROSION RESISTANCE. OCCASIONALLY, HOWEVER, CPVC CAN BE DAMAGED BY CONTACT WITH CHEMICALS FOUND IN SOME CONSTRUCTION MATERIALS 00 SOME WIRES, FLUX, PETROLEUM BASED PRODUCTS, ETC.) AND ANCILLARY PRODUCTS SUCH AS THREAD SEALANTS, LEAK DETECTORS, FIRESTOPS, ETC, ANY PRODUCT THAT COMES IN CONTACT WITH CPVC SPRINKLER PIPE MUST BE EVALUATED IN ACCORDANCE WITH THE SYSTEM COMPATIBILITY PROGRAM AS FOUND AT WWW.SYSTEMCGMPATIBLE.COM COPYRIGHT ALL DOCUMENTS, INCLUDING ORIGINAL DRAWINGS, SPECIFICATIONS, FIELD NOTES, ESTIMATES AND DATA, INCLUDING COMPUTER PROGRAMS PURSUANT TO THIS PROJECT ARE AND WILL REMAIN THE PROPERTY OF WAYNE AUTOMATIC FIRE SPRINKLERS, INC. (WAFS) AS INSTRUMENTS OF SERVICE. THEY ARE NOT INTENDED, NOR REPRESENTED TO BE SUITABLE FOR RE -USE BY THE CLIENT, OR OTHERS, ON EXTENSION OF THIS PROJECT, OR FOR ANY OTHER PROJECT. ANY REUSF, OR ADAPTATION OF THE INFORMATION CONTAINED HEREIN, WITHOUT SPECIFIC WRITTEN PERMISSION FROM WAFS WILL BE AT THE CLIENTS SOLE RISK, WITHOUT LIABILITY, OR LEGAL EXPOSURE TO WAFS, AND VILL ENTITLE WAFS TO FURTHER COMPENSATION AT RATES TO BE AGREED ON BETWEEN WAFS AND THE CLIENT. THE CLIENT SHALL ALSO INDEMNIFY AND HOLD WAFS HARMLESS FROM ANY AND ALL CLAIMS, DAMAGES, LOSSES AND EXPENSES, INCLUDING ATTORNEYS FEES RESULTING FROM ANY SUCH PERMISSIONS. GRAPHICS ELEMENTS NOTE FIRE SPRINKLER CONSTRUCTION DRAWINGS AND SHOP DRAWINGS MAY INCLUDE BACKGROUND DRAWINGS OR GRAPHICS BORROWED FROM THE ARCHITECTURAL CIVIL, STRUCTURAL OR MEP DRAWINGS. THESE REFERENCE BACKGROUND ELEMENTS ARE FOR GENERAL INFORMATION OR CONTEXT ONLY AND THE FIRE SPRINKLER ENGINEER DOES NOT ACCEPT ANY RESPONSIBILITY FOR THESE ELEMENTS. THE FIRE SPRINKLER ENGINEER IS ONLY RESPONSIBLE FOR THOSE PORTIONS OF THE FIRE SPRINKLER DRAWINGS DEPICTING FIRE SPRINKLER SCOPES OF WORK, REFER TO APPROVED ARCHITECTURAL, STRUCTURAL, MEP OR CIVIL DRAWINGS FOR AUTHORITATIVE EXPRESSIONS OF BACKGROUND INFORMATION THAT MAY BE UTILIZED IN FIRE SPRINKLER DRAWINGS OR DETAILS WATER SUPPLY INFORMATION DR13"T UR - ACTUAL EXTRAPOLATED FIRE PUMPca REQ! SIZEi GPM a PSI - STATIC PRESSURE - _ HYDRANT ELEV. - RESIDUAL PRESSURE - -DATE OF TEST_ IN GPM - - TIME OF TEST - �FLOW I PITOT READING - KMBOt OF PORTS FLOM - TEST PROVIDED BY -- PjEkOCATIUN DESIGN CRITERIA SYSTEM / DESIGN AREA # - HAZARD CLASS - # IF SPRINID.ERS IN DESIGNI AREA - MINIMUM DENSITY - DESIGN AREA S,F. - PSI REQ'D @ BR - GPM REQ'D E BR - PSI REQ'D 2 TEST - GPM REQ'D 2 TEST - SHATDN a HOEST SPRDJW - HOSE INSIDE/OUTSIDE - DOMESTIC DEMAND - SPRINKLERS SPACING SYMBOL MAXIMUM MINIMUM COMMENTS Q 15'-0' 6'-0' 130 SQ.FT. MAX COVERAGE �I 'l 0 r— QUANTITY SPRINKLERS YMB. IST 2ND I 3RD 4TH SIN SIZE K TEMP MODEL )R 13 TY3111 1/2' 5.6 155' RELocATEO TYCO TY -L A BRASS UPF 5—A 5 TY3111 1/2' 5.6 155' ADDED TYCO TY -L ,SR, BRASS UPRIGHT WSTD(G UPRIGHT TO BE REMDIM TOTAL PER FLOOR 18 TOTAL THIS SHEET 'E SUBMITTAIS l• — I — I — I III /1\ I XX/XX/XX I -- I - I W WAYNE Automatic Fire Sprinklers, Inc. MAIN OFFICE — ORLANDO. FLORIDA 222 CAPITOL COURT OCOE -_ FLOWA 34761 PHONE (4077 666-3030 FAX: ( 866-8026 ,u►CanWu a R. TAWA. R. R76F MM WAM R. 11326 011 AVE WEST 3226 amy PALM DIM 30 NW 16TH TINFACE JAQXSONVLLE FL 32256-2746 TAMPA, FL 338 7 POWANO BEACH. FL 33084 -MOB PHONE (804) 268-3030 PHONE (813) 830-0303 PHONE O)64) 99-3030 FAX: (904) 288-0724 FAX (818) 830 -OM FAX (864) BO' -8424 FT. mym R. COBS IAC STATE UC06M 4883 LQ:EDO AVE 4370 MOTORSPORT DAM NC SPRNO.m 28745 FT. MYM FL 33805-4824 CONCORD, NO 28027 77 NC ALARM 29M SP LV PHONE MM) 433-303D PHONE (704) 782-3032 ec elm 116 FAX (238) 433-3283 FAX (704) 786-6839 SC ALARM 3386 Winn Dixie #259 1620 S. Federal Hwy Boynton Beach, Florida 33435 Winn Dixie Maintenance 1141 SW 12th Ave Pompano Beach, FL 33069 SHEET TITLE, Notes &Details DRAWN BY, Michael Crawford TOTAL A/S, 18 DATE, 1/29/2015 AHJ, City of Boynton Beach CONTRACT # #9595 CENTER OF TILE JOB? [-] YES NO CENTER ON FIXTURES JOB? ❑ YES QTNO SHEET # CONSTRUCTION TYPD IS FP2 OCCUPANCYi M r