DRAWINGSEXISTING
CONCRETE
BEAM.
EXISTING
EMBEDDEL
STEEL PLA
_LD TO EX/STING PLA TE.
-W TS.
COLUMNS (Fy = 36 KSI)
TYPICAL CAP PLATE
DETAIL FOR REUSABLE
EXISTING TOP PLATE
SCALE: 1/2"=1'-0"
cxr=NWR4�. CONSTRUCTION NOTES:
I. ALL CONSTRUCTION SHALL CONFORM TO ALL CODE REGULATIONS AND
RESTRICTIONS HAVING JURISDICTION.
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS
ON THIS PROJECT PRIOR TO BEGINNING CONSTRUCTION.
NOTIFY ARCHITECT IN WRITING IMMEDIATELY OF ANY DISCREPANCIES,
OR THE CONTRACTOR SHALL ACCEPT FULL RESPONSIBILITY FOR
ANY ERRORS OR OMISSIONS. DIMENSIONS TAKE PRECEDENCE OVER
SCALED DRAWINGS.
3. ALL PRODUCTS AND MATERIALS SHALL BE APPLIED OR INSTALLED
ACCORDING TO MANUFACTURER'S PUBLISHED INSTRUCTIONS, OR IF
NO INSTRUCTIONS EXIST, APPLY OR INSTALL AS PER STANDARD
INDUSTRY PRACTICE.
4. SUBMIT A COPY OF THE CONTRACT DOCUMENTS (THAT WERE ISSUED
FOR PERMIT) TO THE ARCHITECT WHEN RETURNED BY THE BUILDING
DEPARTMENT AFTER PERMIT 15 ISSUED. THIS WILL ALLOW THE ARCHITECT
TO INCORPORATE ANY BUILDING DEPARTMENT NODI H CATI ONS INTO THE
CONTRACT DOCUMENTS PRIOR TO START OF CONSTRUCTION.
5. CONTRACTOR SHALL NOTIFY THE ARCHITECT (IN WRITING)
IMMEDIATELY OF ANY ERRORS AND OMISSIONS ON THESE
DRAWINGS.
NEW 2500 PSI CONCRETE
PEDESTAL WRAP. COA T
COLUMN WITH MASTIC &
COVER WITH BUILD/NG
PAPER.
EXISTING
EMBEDDED
STEEL PLA TE.
NEW IS. 4':Y4 "M/4"
COLUMNS (Fy = 36 KS/)
EXIST/NG CONCRETE SLAB
& THICKENED EDGE.
TYP. 1
7—� WELD TO EXISTING PLATE.
4"
`—EXISTING FOOT/NG PAD.
TYPICAL BASE PLATE
DETAIL FOR REUSABLE
EXISTING BASE PLATE 3
SCALE: 1/2"=V-0"
SCALE: 1 /2"=1'-0"
STRUCTURAL STEEL: SHALL CONFORM TO THE FOLLOWING ASTM DESIGNATIONS
(UNLESS NOTED OTHERWISE). PLATES, SHAPES, ANCHORS BOLTS -A36-, PIPE COLUMNS
A-501, WELDS AWS A 5-1, E-70XX ELECTRODE. STEEL TO RECEIVE SHOP
COATS AND FIELD TOUCH-UP OF PAINT IN ACCORDANCE WITH SSPC SPECIFICATIONS.
ALL WELDING, SHOP FABRICATION AND SHOP PAINTING SHALL CONFORM TO THE
AISC SPECIFICATIONS (EIGHTH EDITION), FOR THE DESIGN, FABRICATION AND
ERECTION OF STRUCTURAL STEEL FOR BUILDINGS. SHOP DRAWINGS SHALL BE
SUBMITTED FOR REVIEW.
GENERAL STRUCTURAL NOTES:
ERECTION:
THE BUILDING CONTRACTOR SHALL BE RESPONSIBLE FOR THE ERECTION AND SAFE STABILITY OF THE FRAME UNTIL THE STRUCTURAL SYSTEM
IS COMPLETE AND CAPABLE OF RESISTING ALL DESIGN FORCES. MAKE ADEQUATE PROVISIONS FOR ERECTION STRESSES AND FOR SUFFICIENT
TEMPORARY BRACING TO KEEP THE STRUCTURAL SYSTEM PLUMB AND IN TRUE ALIGNMENT UNTIL COMPLETION. INCLUDING ALL THE ELEMENTS
WHICH ARE A PART OF THE WIND RESISTING SYSTEN. ERECTION OPERATIONS, INCLUDING THE INSTALLATION OF TEMPORARY SHORING, SHALL
BE CARRIED OUT WITHOUT LOADING PORTIONS OF THE STRUCTURAL FRAME AND NON-STRUCTURAL CONSTRUCTION IN EXCESS OF THEIR SAFE
LOAD CARRYING CAPACITY. WHERE THE LOAD CAPACITY OF THE STRUCTURE MAY BE EXCEEDED, SHORE CONSTRUCTED PORTIONS OF THE
STRUCTURE, AS REQUIRED, TO POSITIVE FOUNDATION SUPPORTS. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL
DI MENSI ONS IN THE FIELD. ANY INSPECTIONS BY THE ARCHITECT ARE IN THE FORM OF RANDOM SAMPLING QUALITY ONLY AND DO NOT RELIEVE
THE GENERAL CONTRACTOR FROM HIS RESPONSIBILITY OF BUILDING ACCORDING TO THE REVIEWED DRAWINGS.
SHOP DRAWINGS:
7 DAYS FOR REVIEW PLUS TIME FOR REDRAWING OF CORRECTED ITEMS. SECURE WRITTEN REVIEW FROM THE ARCHITECT PRIOR TO FABRICATION,
ERECTION OR INSTALLATION. ANY REVIEW BY ARCHITECT OF SUCH SHOP DRAWINGS DOES NOT RELIEVE THE GENERAL CONTRACTOR FROM HIS
RESPONSIBILITY OF BUILDING ACCORDING TO CONTRACT DOCUMENTS UNLESS SPECIFICALLY NOTED OTHERWISE.
NOTE: WIND DESIGN INFORMATION
PROVIDE TEMPORARY SHORING FOR CODE EDITION: 2014 EDITION OF THE FLORIDA BUILDING CODE
EXISTING STRUCTURE TO RELIEVE LOAD 170 M.P.H. (3 SECOND GUST)
PRIOR TO CUTTING EXISTING STEEL COLUMNS. IMPORTANCE FACTOR = I BUILDING CATAGORY= 11
WIND EXPOSURE = "B"
INTERNAL PRESSURE COEFF. = 0.15
MEAN ROOF HEIGHT = 23'-0"
CONCRETE REPAIR NOTES:
SPALLED CONCRETE: SHORE EXISTING CONCRETE BEAM BELOW TO GROUND LEVEL PRIOR TO PERFORMING ANY WORK.
CHIP TO REMOVE ANY LOOSE CONCRETE BACK TO SOLID MATERIAL. SANDBLAST OR PRESSURE WASH AS REQUIRED
TO CLEAN BOTH REINFORCING STEEL AND CONCRETE AS REQUIRED. PATCH REMOVED MATERIAL WITH SIKAQUICK VOH
REPAIR MORTAR AND SI KADUR 32, HI -MODULUS HIGH STRENGTH EPDXY BONDING ADHESIVE. PREPARE AND INSTALL
AS PER ALL MANUFACTURER'S PRINTED INSTRUCTIONS. PRODUCTS BY:
SIKA CORPORATION
201 POLITO AVENUE
LYNDHURST, NEW JERSEY 07071
(600) q33-7452
INSTALLATION REQUIRES MAXIMUM REPAIR AREAS AT ANY ONE TIME. ALLOW FOR CURING AS INSTRUCTED BY THE
MANUFACTURER BEFORE ADDING NEXT LIFT. NOTIFY ARCHITECT OF ANY DESCREPANCIES FOUND UPON REMOVAL OF
EXISTING CONCRETE PRIOR TO REINSTALLING NEW MATERIAL. ALL REPAIRS ARE TO BE PER THE INTERNATIONAL
CONCRETE REPAIR INSTITUTE TECHNICAL GUIDELINES "GUI DELI NE NO. 310JR-2008". ARCHITECT WILL REQUIRE NOTIFICATION
UPON REMOVAL OF EXISTING LOOSE MATERIAL FOR SITE OBSERVATION PRIOR TO REPLACING NEW MATERIAL.
GENERAL CODE INFORMATION
CODE
- 2014 EDITION OF THE FLORIDA BUILDING CODE
- 2014 EDITION OF THE FLORIDA EXISTING BUILDING CODE
5/8„
EXIST/NC
CONCREit
BEAM.
IS. 4'X4'A4/4"
MNS (Fy = 36 KSI)
3/4"0 X 4%2" EMBEDDED
RETE SCREWS.
A'rW
BASE
EX/ST/NG
CONCRETE
BEAM.
SIDE VIEW PLAN VIEW
STANDARD @ SECOND FLOOR ONL Y.
USE ONL Y /F EXISTING BASE PLA TE
IS DEEMED NOT USABLE (V.I.F.)
STEEL COLUMN BASE DETAIL O3
SCALE: 1/2"=1'-0"
I
(2) 112"0 ALL -THREAD RODS (M/N. 3" NEW IS. \ COLUMN BELOW 4" =36
EMBED INTO EXIST'G. CONC. BEAM).(Fy
ANCHOR W/ HIL TI HY-200 EPDXY. KSI)
PROVIDE NUT & WASHER. MIN. 2" CLEAR
FROM EDGES OF CONCRETE PL A N VIEW
STANDARD @ SECOND FLOOR SLAB &
ROOF BEAM. USE ONL Y IF EXISTING CAP
PLATE IS DEEMED NOT USABLE (V.I.F.)
STEEL COLUMN CAP PLATE DETAIL 60
SCALE: 1/2"=1'-0"
AFFECTED UNITS (PER HOA):
EA5IGATC-
70-D
NEW IS. 4'X4'A%"
COL UMNS (Fy = 36 KSI)
°
A IrIA/
BASE
EXISTING
CONCRETE
BEAM.
° (4) f/4"o X 4'/2'" EMBEDDED
EXISTING 12» CONCRETE SCREWS.
CONCRETE
BEAM. SIDE VIEW PLAN VIEW
STANDARD @ SECOND FLOOR ONL Y.
USE ONL Y IF EXISTING BASE PLA TE
IS DEEMED NOT USABLE (V.I.F.)
STEEL COLUMN BASE DETAIL
SCALE: 1/2"=V-0"
NEW %2" THICK
�4„ COLUMN CAP
EXISTING
CONCRETE
N r 7 BEAM.
LL A,
(2) 1/2"0 ALL -THREAD RODS (MIN. 3" NEW IS. 4'X4'44"
EMBED INTO EXIST'GG, CONC. BEAM). COLUMN BELOW (Fy =36
ANCHOR W/ HIL TI HY-200 EPDXY. KSI)
PROVIDE NUT & WASHER. MIN. 2" CLEAR
FROM EDGES OF CONCRETE PLAN VIEW
STANDARD @ SECOND FLOOR SLAB &
ROOF BEAM. USE ONL Y /F EXISTING CAP
PLATE IS DEEMED NOT USABLE (VA F)
STEEL COLUMN CAP PLATE DETAIL
SCALE: 1/2"=l' -O"
REMOVE STUCCO TO EXPOSE CONCRETE.
AFTER NEW /NSTALLA TION, PA TCH TO MA TCH -
EX/ST/NG CONSTRUCTION. (TYP.)
SEE DETAIL #1 FOR TYPICAL CAP PLA TE DETAIL
FOR REUSABLE EXIST/NG CAP PLA TE.
SEE DETAIL #6 FOR TYPICAL CAP PLA TE DETAIL
FOR UNUSABLE EXISTING CORNER CAP PLATE.
SEE DETAIL #7 FOR TYPICAL CAP PLA TE DETAIL
FOR UNUSABLE EX/ST/NG INTER/OR CAP PLATE.
REPLACE EXISTING STEEL COLUMNS
WITH NEW SEE DETAILS.
SEE DETAIL #3 OR #6 FOR UNUSABLE BASE
PLATE FOR CORNER 2ND FLOOR COL UMN.
SEE DETAIL #4 OR #7 FOR UNUSABLE BASE
PLA TE FOR IN 2ND FLOOR COLUMN.
NO TE.-
VERIFY IN FIELD EXISTING BASE PLA TE
CONDITIONS USE SIKAQUICK VOH REPAIR
MORTAR TO PA TCH EXIST/NG BEAM &
SLABS AS REQUIRED. TYPICAL ONLY @
DETAIL 3 OR 4. SEE ADDI TONAL NOTES
FOR DETAIL 6. REFER TO CONCRETE
REPAIR NOTES
SEE DETAIL #1 FOR TYPICAL CAP PLA TE DETAIL
FOR REUSABLE EXIST/NG CAP PLA TE.
SEE DETAIL #6 FOR TYPICAL CAP PLA TE DETAIL
FOR UNUSABLE EX/ST/NG CAP PLA TE.
REPLACE EXISTING STEEL COLUMNS -�
WITH NEW SEE DETAILS.
SEE DETA/L #2 FOR TYPICAL BASE PLA TE —
DETAIL FOR REUSABLE EXISTING BASE PLA TE.
SEE DETAIL #5 FOR TYP/CAL BASE PLA TE —
DETA/L FOR UNUSABLE EXISTING BASE PLATE.
GRADE
EXISTING CONCRETE SLAB
& THICKENED EDGE.
EXISTING FOOTING PAD.
PARTIAL TWO STORY ELEVATION
SCALE: N.T.S.
EXISTING ROOF
STRUCTURE.
EXISTING CONCRETE BEAM
@ SECOND STORY.
EXISTING CONCRETE BEAM
@ SECOND FL OOR.
SCOTT D. DYER
ARCHITECT, P.A.
AA C001929
AR 0011551
6671 CONCH COURT
BOYNTON BEACH, FLORIDA
33437
(561) 596-7503
- THIS DRAWING, AS AN INSTRUMENT OF
SERVICE IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE USED ON
OTHER WORK, REPRODUCED IN WHOLE OR
IN PART, WITHOUT THE ARCHITECT'S
EXPRESS WRITTEN CONSENT.
TO THE BEST OF MY KNOWLEDGE, THE
DRAWINGS AND SPECIFICATIONS SUBMITTED
HEREWITH, COMPLY WITH EXISTING
INTERPRETATIONS AND PROVISIONS OF
THE APPLICABLE BUILDING CODES IN
EFFECT AT THE DATE SHOWN BELOW. NO
WARRANTY EXPRESS OR IMPLIED IS
HEREBY GIVEN.
COPYRIGHT D 20
SCOTT D. DYER AHITEC
ALL RIGHTS RESE ED
sE��a
SCOTT D. DYER AR -0011551
REVISIONS
COMM. NO.
15-047
DATE
30 SEPTEMBER 2015
BOYNTON 56ACH,
LORID.4
SHEET
A 1
OF 1
STANDARD @ FIRST FLOOR ONL Y.
USE ONL Y IF EXISTING BASE PLA
TE
/S DEEMED NOT USABLE (V./.F.)
NEW 2500 PSI CONCRETE
NEW IS. 4'X4'://4"
PEDESTAL WRAP. COA T
COLUMNS (Fy = 36 KS/)
COLUMN WITH MASTIC &
COVER WITH BUILD/NG
EXISTING CONCRETE SLAB
PAPER.
& THICKENED EDGE.
NEW 8'XS'X3/4"
THK. BASE
PLA TE W/ (3)
1/2" DIA,
TYP.
ALL- THREAD
WELD TO EX/STING PLATE.
RODS (M/N. 5"
%4"
EMBED INTO
FOO TING).
PROVIDE NUT &
WASHER.
EXIST/NG FOOTING PAD.
NEW BASE PLATE
DETAIL FOR UNUSABLE
EXISTING BASE PLATE
O
SCALE: 1 /2"=1'-0"
STRUCTURAL STEEL: SHALL CONFORM TO THE FOLLOWING ASTM DESIGNATIONS
(UNLESS NOTED OTHERWISE). PLATES, SHAPES, ANCHORS BOLTS -A36-, PIPE COLUMNS
A-501, WELDS AWS A 5-1, E-70XX ELECTRODE. STEEL TO RECEIVE SHOP
COATS AND FIELD TOUCH-UP OF PAINT IN ACCORDANCE WITH SSPC SPECIFICATIONS.
ALL WELDING, SHOP FABRICATION AND SHOP PAINTING SHALL CONFORM TO THE
AISC SPECIFICATIONS (EIGHTH EDITION), FOR THE DESIGN, FABRICATION AND
ERECTION OF STRUCTURAL STEEL FOR BUILDINGS. SHOP DRAWINGS SHALL BE
SUBMITTED FOR REVIEW.
GENERAL STRUCTURAL NOTES:
ERECTION:
THE BUILDING CONTRACTOR SHALL BE RESPONSIBLE FOR THE ERECTION AND SAFE STABILITY OF THE FRAME UNTIL THE STRUCTURAL SYSTEM
IS COMPLETE AND CAPABLE OF RESISTING ALL DESIGN FORCES. MAKE ADEQUATE PROVISIONS FOR ERECTION STRESSES AND FOR SUFFICIENT
TEMPORARY BRACING TO KEEP THE STRUCTURAL SYSTEM PLUMB AND IN TRUE ALIGNMENT UNTIL COMPLETION. INCLUDING ALL THE ELEMENTS
WHICH ARE A PART OF THE WIND RESISTING SYSTEN. ERECTION OPERATIONS, INCLUDING THE INSTALLATION OF TEMPORARY SHORING, SHALL
BE CARRIED OUT WITHOUT LOADING PORTIONS OF THE STRUCTURAL FRAME AND NON-STRUCTURAL CONSTRUCTION IN EXCESS OF THEIR SAFE
LOAD CARRYING CAPACITY. WHERE THE LOAD CAPACITY OF THE STRUCTURE MAY BE EXCEEDED, SHORE CONSTRUCTED PORTIONS OF THE
STRUCTURE, AS REQUIRED, TO POSITIVE FOUNDATION SUPPORTS. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL
DI MENSI ONS IN THE FIELD. ANY INSPECTIONS BY THE ARCHITECT ARE IN THE FORM OF RANDOM SAMPLING QUALITY ONLY AND DO NOT RELIEVE
THE GENERAL CONTRACTOR FROM HIS RESPONSIBILITY OF BUILDING ACCORDING TO THE REVIEWED DRAWINGS.
SHOP DRAWINGS:
7 DAYS FOR REVIEW PLUS TIME FOR REDRAWING OF CORRECTED ITEMS. SECURE WRITTEN REVIEW FROM THE ARCHITECT PRIOR TO FABRICATION,
ERECTION OR INSTALLATION. ANY REVIEW BY ARCHITECT OF SUCH SHOP DRAWINGS DOES NOT RELIEVE THE GENERAL CONTRACTOR FROM HIS
RESPONSIBILITY OF BUILDING ACCORDING TO CONTRACT DOCUMENTS UNLESS SPECIFICALLY NOTED OTHERWISE.
NOTE: WIND DESIGN INFORMATION
PROVIDE TEMPORARY SHORING FOR CODE EDITION: 2014 EDITION OF THE FLORIDA BUILDING CODE
EXISTING STRUCTURE TO RELIEVE LOAD 170 M.P.H. (3 SECOND GUST)
PRIOR TO CUTTING EXISTING STEEL COLUMNS. IMPORTANCE FACTOR = I BUILDING CATAGORY= 11
WIND EXPOSURE = "B"
INTERNAL PRESSURE COEFF. = 0.15
MEAN ROOF HEIGHT = 23'-0"
CONCRETE REPAIR NOTES:
SPALLED CONCRETE: SHORE EXISTING CONCRETE BEAM BELOW TO GROUND LEVEL PRIOR TO PERFORMING ANY WORK.
CHIP TO REMOVE ANY LOOSE CONCRETE BACK TO SOLID MATERIAL. SANDBLAST OR PRESSURE WASH AS REQUIRED
TO CLEAN BOTH REINFORCING STEEL AND CONCRETE AS REQUIRED. PATCH REMOVED MATERIAL WITH SIKAQUICK VOH
REPAIR MORTAR AND SI KADUR 32, HI -MODULUS HIGH STRENGTH EPDXY BONDING ADHESIVE. PREPARE AND INSTALL
AS PER ALL MANUFACTURER'S PRINTED INSTRUCTIONS. PRODUCTS BY:
SIKA CORPORATION
201 POLITO AVENUE
LYNDHURST, NEW JERSEY 07071
(600) q33-7452
INSTALLATION REQUIRES MAXIMUM REPAIR AREAS AT ANY ONE TIME. ALLOW FOR CURING AS INSTRUCTED BY THE
MANUFACTURER BEFORE ADDING NEXT LIFT. NOTIFY ARCHITECT OF ANY DESCREPANCIES FOUND UPON REMOVAL OF
EXISTING CONCRETE PRIOR TO REINSTALLING NEW MATERIAL. ALL REPAIRS ARE TO BE PER THE INTERNATIONAL
CONCRETE REPAIR INSTITUTE TECHNICAL GUIDELINES "GUI DELI NE NO. 310JR-2008". ARCHITECT WILL REQUIRE NOTIFICATION
UPON REMOVAL OF EXISTING LOOSE MATERIAL FOR SITE OBSERVATION PRIOR TO REPLACING NEW MATERIAL.
GENERAL CODE INFORMATION
CODE
- 2014 EDITION OF THE FLORIDA BUILDING CODE
- 2014 EDITION OF THE FLORIDA EXISTING BUILDING CODE
5/8„
EXIST/NC
CONCREit
BEAM.
IS. 4'X4'A4/4"
MNS (Fy = 36 KSI)
3/4"0 X 4%2" EMBEDDED
RETE SCREWS.
A'rW
BASE
EX/ST/NG
CONCRETE
BEAM.
SIDE VIEW PLAN VIEW
STANDARD @ SECOND FLOOR ONL Y.
USE ONL Y /F EXISTING BASE PLA TE
IS DEEMED NOT USABLE (V.I.F.)
STEEL COLUMN BASE DETAIL O3
SCALE: 1/2"=1'-0"
I
(2) 112"0 ALL -THREAD RODS (M/N. 3" NEW IS. \ COLUMN BELOW 4" =36
EMBED INTO EXIST'G. CONC. BEAM).(Fy
ANCHOR W/ HIL TI HY-200 EPDXY. KSI)
PROVIDE NUT & WASHER. MIN. 2" CLEAR
FROM EDGES OF CONCRETE PL A N VIEW
STANDARD @ SECOND FLOOR SLAB &
ROOF BEAM. USE ONL Y IF EXISTING CAP
PLATE IS DEEMED NOT USABLE (V.I.F.)
STEEL COLUMN CAP PLATE DETAIL 60
SCALE: 1/2"=1'-0"
AFFECTED UNITS (PER HOA):
EA5IGATC-
70-D
NEW IS. 4'X4'A%"
COL UMNS (Fy = 36 KSI)
°
A IrIA/
BASE
EXISTING
CONCRETE
BEAM.
° (4) f/4"o X 4'/2'" EMBEDDED
EXISTING 12» CONCRETE SCREWS.
CONCRETE
BEAM. SIDE VIEW PLAN VIEW
STANDARD @ SECOND FLOOR ONL Y.
USE ONL Y IF EXISTING BASE PLA TE
IS DEEMED NOT USABLE (V.I.F.)
STEEL COLUMN BASE DETAIL
SCALE: 1/2"=V-0"
NEW %2" THICK
�4„ COLUMN CAP
EXISTING
CONCRETE
N r 7 BEAM.
LL A,
(2) 1/2"0 ALL -THREAD RODS (MIN. 3" NEW IS. 4'X4'44"
EMBED INTO EXIST'GG, CONC. BEAM). COLUMN BELOW (Fy =36
ANCHOR W/ HIL TI HY-200 EPDXY. KSI)
PROVIDE NUT & WASHER. MIN. 2" CLEAR
FROM EDGES OF CONCRETE PLAN VIEW
STANDARD @ SECOND FLOOR SLAB &
ROOF BEAM. USE ONL Y /F EXISTING CAP
PLATE IS DEEMED NOT USABLE (VA F)
STEEL COLUMN CAP PLATE DETAIL
SCALE: 1/2"=l' -O"
REMOVE STUCCO TO EXPOSE CONCRETE.
AFTER NEW /NSTALLA TION, PA TCH TO MA TCH -
EX/ST/NG CONSTRUCTION. (TYP.)
SEE DETAIL #1 FOR TYPICAL CAP PLA TE DETAIL
FOR REUSABLE EXIST/NG CAP PLA TE.
SEE DETAIL #6 FOR TYPICAL CAP PLA TE DETAIL
FOR UNUSABLE EXISTING CORNER CAP PLATE.
SEE DETAIL #7 FOR TYPICAL CAP PLA TE DETAIL
FOR UNUSABLE EX/ST/NG INTER/OR CAP PLATE.
REPLACE EXISTING STEEL COLUMNS
WITH NEW SEE DETAILS.
SEE DETAIL #3 OR #6 FOR UNUSABLE BASE
PLATE FOR CORNER 2ND FLOOR COL UMN.
SEE DETAIL #4 OR #7 FOR UNUSABLE BASE
PLA TE FOR IN 2ND FLOOR COLUMN.
NO TE.-
VERIFY IN FIELD EXISTING BASE PLA TE
CONDITIONS USE SIKAQUICK VOH REPAIR
MORTAR TO PA TCH EXIST/NG BEAM &
SLABS AS REQUIRED. TYPICAL ONLY @
DETAIL 3 OR 4. SEE ADDI TONAL NOTES
FOR DETAIL 6. REFER TO CONCRETE
REPAIR NOTES
SEE DETAIL #1 FOR TYPICAL CAP PLA TE DETAIL
FOR REUSABLE EXIST/NG CAP PLA TE.
SEE DETAIL #6 FOR TYPICAL CAP PLA TE DETAIL
FOR UNUSABLE EX/ST/NG CAP PLA TE.
REPLACE EXISTING STEEL COLUMNS -�
WITH NEW SEE DETAILS.
SEE DETA/L #2 FOR TYPICAL BASE PLA TE —
DETAIL FOR REUSABLE EXISTING BASE PLA TE.
SEE DETAIL #5 FOR TYP/CAL BASE PLA TE —
DETA/L FOR UNUSABLE EXISTING BASE PLATE.
GRADE
EXISTING CONCRETE SLAB
& THICKENED EDGE.
EXISTING FOOTING PAD.
PARTIAL TWO STORY ELEVATION
SCALE: N.T.S.
EXISTING ROOF
STRUCTURE.
EXISTING CONCRETE BEAM
@ SECOND STORY.
EXISTING CONCRETE BEAM
@ SECOND FL OOR.
SCOTT D. DYER
ARCHITECT, P.A.
AA C001929
AR 0011551
6671 CONCH COURT
BOYNTON BEACH, FLORIDA
33437
(561) 596-7503
- THIS DRAWING, AS AN INSTRUMENT OF
SERVICE IS THE PROPERTY OF THE
ARCHITECT AND IS NOT TO BE USED ON
OTHER WORK, REPRODUCED IN WHOLE OR
IN PART, WITHOUT THE ARCHITECT'S
EXPRESS WRITTEN CONSENT.
TO THE BEST OF MY KNOWLEDGE, THE
DRAWINGS AND SPECIFICATIONS SUBMITTED
HEREWITH, COMPLY WITH EXISTING
INTERPRETATIONS AND PROVISIONS OF
THE APPLICABLE BUILDING CODES IN
EFFECT AT THE DATE SHOWN BELOW. NO
WARRANTY EXPRESS OR IMPLIED IS
HEREBY GIVEN.
COPYRIGHT D 20
SCOTT D. DYER AHITEC
ALL RIGHTS RESE ED
sE��a
SCOTT D. DYER AR -0011551
REVISIONS
COMM. NO.
15-047
DATE
30 SEPTEMBER 2015
BOYNTON 56ACH,
LORID.4
SHEET
A 1
OF 1