DRAWINGS511 0 -16/2 FPLP NOTIFICATION WIRE 1-1 1-2 1-3 1-4 PARTIAL PLAN -*- 1/8 •-"-0• NORTH 1-5 1-6 1-7 1-8 1-9 1--10 1-11 PARTIAL FIRE ALARM RI SER�� p•T•s NORTH TO THE BOTTOM OF 80" A.F.F. OR HORN/STROBE 1 x-11 6" BELOW CEILING R (WHICHEVER IS LOWER) E II I II ll II II ll II I II it II II II II PULL STATION I 48" A.F.F. — �i--- J ADA HEIGHT REQUIREMENTS N.T.S. A111 Electrical work shall comply W1. ',. J srvstvvE ll 1` DATE s .Y tEc�ri�.al "' Plumbing M1,.<<chaliical . is e Processed s by: All vrork invoiced on this permit sha(I can4orm taut: aiS Cit� o; 8ayrton Beach Building Codes WIRE LEGEND DESIGNATION WIRE A 16/2 FPLP NOTIFICATION WIRE DEVICE LEGEND SYMBOL DEVICE INN A_c 1 NEW NOTIFICATION POWER BOOSTER WALL MOUNTED STROBE ONLY UNIT WALL MOUNTED HORN/STROBE UNIT O E EXISITNG SMOKE DETECTOR REVISION NO. DATE , DESCRIPTION FAA ISSUE DATE: KFS/MTW 9.24.15 0 to 0 � W M M w� F 0 W 0-4 U� �uav" 00 r l 00 W 0? >�CH w ril aHo� po a U �QZl Q Ou U 1--, � � R4 [-{ a 5ua� W¢w� �H N mo o4 V UwU W coo 0 REVISION NO. DATE , DESCRIPTION FAA ISSUE DATE: KFS/MTW 9.24.15 0 � M M w� 0 W tV �uav" 00 r l 00 W 0? >�CH aHo� po a U �QZl W Ou U 1--, rH„wvi�a � [-{ a 5ua� W¢w� �H h� FT+I�i W U V UwU � z M N REVISION NO. DATE , DESCRIPTION FAA ISSUE DATE: KFS/MTW 9.24.15 FIRE ALARM GENERAL NOTES: ABBREVIATIONS: AHJ - AUTHORITY HAVING JURISDICTION (FIRE DEPARTMENT) FACP - FIRE ALARM CONTROL PANEL FCPS - FIRE CONTROL POWER SUPPLY NFPA - NATIONAL FIRE PROTECTION ASSOCIATION NRTL - NATIONALLY RECOGNIZED TESTING LABORATORY (ETL, FM, UL) SCOPE OF WORK INSTALLATION OF A FIRE ALARM SYSTEM IN ACCORDANCE WITH NFPA 72, STATE, AND LOCALLY ADOPTED CODES AND ORDINANCES. APPLICABLE CODES BASIC CONSTRUCTION AND DESIGN REQUIREMENTS AND CODE COMPLIANCE. STATE CODE OF REGULATIONS THE INSTALLATION OF THE FIRE ALARM SYSTEM SHALL COMPLY WITH THE CURRENT STATE, COUNTY, LOCAL, MUNICIPAL AHJ ADOPTED CODES OR ORDINANCES THAT ARE IN WRITTEN FORM. FLORIDA BUILDING CODE AND FLORIDA FIRE PREVENTION CODE THE INSTALLATION OF THE FIRE ALARM EQUIPMENT SHALL BE IN ACCORDANCE WITH NFPA 1 - NFPA 72 - NFPA 101. ANY REQUIRED CORRECTIONS OR DISAPPROVALS SHALL BE IN WRITING WITH ADOPTED CODE, ORDINANCE OR OTHER REFERENCED LANGUAGE PER THE AHJ. • ALARM INSTALLER INFORMATION SHALL BE PROVIDED PRIOR TO START OF INSTALLATION OR WHEN CONTRACTED FOR INSTALLATION. • THE FIRE ALARM INSTALLER IN CHARGE OF THIS PROJECT SHALL BE CERTIFIED AND LICENSED BY THE STATE OF FLORIDA AND/OR LOCAL REQUIREMENTS. PROOF OF SUCH CERTIFICATION SHALL BE ON THE INSTALLER AT ALL TIMES AND SHALL BE PROVIDED UPON REQUEST BY THE AHJ. • INSTALLER IN CHARGE SHALL COORDINATE ALL WORK WITH THE OWNER/PROPERTY MANAGER AND ALL OTHER TRADES. • CONSULT WITH LOCAL AHJ, OWNER AND/OR OTHER TRADES FOR EXACT LOCATION OF THE FIRE CONTROL PANEL AND ALL DEVICES PRIOR TO INSTALLATION. • THE EQUIPMENT AND MATERIAL SHALL BE STATE OF FLORIDA FIRE MARSHAL LISTED AND APPROVED FOR USE AS SET FORTH BY NFPA 72 AND NRTL STANDARDS. • THE FIRE ALARM CONTRACTOR SERVICE, MAINTENANCE, TESTING AND MONITORING CONTRACTS SHALL BE SUBMITTED TO THE AHJ PRIOR TO CONDUCTING ACCEPTANCE TEST. • THE FIRE ALARM SERVICE, MAINTENANCE, TESTING AND MONITORING PROVIDER SHALL BE CENTRAL STATION SERVICE CERTIFIED BY A NRTL. PROOF OF CERTIFICATION SHALL BE SUBMITTED TO THE AHJ PRIOR TO CONDUCTING ACCEPTANCE TEST. SYSTEM INSTALLATION • THE STATE OF FLORIDA LICENSED ELECTRICAL CONTRACTOR SHALL PROVIDE A 120 VAC 15 OR 20 AMP DEDICATED CIRCUIT TO THE LOCATION OF THE FACP / FCPS AND OTHER PANELS REQUIRING PRIMARY POWER. • THE CIRCUIT SHALL BE MECHANICALLY PROTECTED WITH A LISTED -BREAKER LOCK -OUT DEVICE THAT MEETS OSHA 1910.147. (EXAMPLE DEVICE - MASTER LOCK 4938) EXCEPTION: BREAKER LOCATED WITHIN LOCKED CABINET OR ROOM THAT IS ACCESSIBLE TO AUTHORIZED PERSONNEL ONLY. • THE MULTIPLE PANEL ARRANGEMENT IN A SINGLE LOCATION SHALL REQUIRE JUNCTION BOXES FOR 120 VAC CIRCUIT SPLICES. MULTIPLE CONDUCTORS UNDER SINGLE TERMINALS OR WIRE SPLICED WITHIN CONTROL PANEL EQUIPMENT WILL NOT BE ALLOWED. • THE DEDICATED 120 VAC BRANCH CIRCUIT SHALL BE CLEARLY IDENTIFIED AND LABELED "FIRE ALARM CIRCUIT" IN RED. • LOCATION OF THE CIRCUIT BREAKER CONNECTED TO EACH CONTROL PANEL SHALL BE LABELED WITHIN EACH CONTROL PANEL. • POWER LIMITED WIRING SHALL BE SEPARATED FROM NON -POWER LIMITED WIRING AND CLASS 1 CIRCUITS A MINIMUM OF .25 INCHES OR AS INSTRUCTED BY THE CONTROL PANEL MANUFACTURER. • ALL CIRCUITS WILL BE IDENTIFIED AT JUNCTIONS AND AT TERMINATION BY MEANS OF A DURABLE PERMANENT AND VISIBLE LABEL. • ALL WIRING AND CABLING METHODS SHALL COMPLY WITH NATIONAL ELECTRIC ,CODE 70 ARTICLE 760. • NO "T" TAPPING OF FIELD WIRINGS IS ALLOWED ON SUPERVISED 'CIRCUITS, EXCEPTION: SLC/DATA CIRCUITS PER MANUFACTURERS SPECIFICATIONS. RETRANSMISSION OF SIGNALS • THE FIRE ALARM SYSTEM SHALL BE EQUIPPED WITH TWO AHJ ACCEPTABLE, NRTL CENTRAL STATION LISTED MEANS OF TRANSMISSION OF ALL SIGNALS TO AN AHJ ACCEPTABLE, NRTL LISTED CENTRAL MONITORING STATION. • THE MEANS OF TRANSMISSIONS SHALL BE PROGRAMMED TO INITIATE AND COMPLETE A TEST SIGNAL EVERY 24 HOURS MINIMUM. EACH PATH CAN ALTERNATE 24 HOUR PERIODS AS LONG AS THE CENTRAL STATION RECEIVES A SIGNAL EVERY 24 HOURS. • A LOCAL TROUBLE SHALL SOUND AND BE LOCATED SUCH THAT IT CAN BE HEARD WITHIN OCCUPIABLE SPACE IF ONE OF THE MEANS OF TRANSMISSION IS COMPROMISED OR FAILS ON A SIGNAL TRANSMISSION ATTEMPT. • THE PROTECTED PROPERTY CONTACT LIST WITH NAMES AND CALL NUMBERS OF AT LEAT THREE INDIVIDUALS RESPONSIBLE FOR THE PROTECTED PROPERTY SHALL BE PROVIDED TO THE AHJ PRIOR TO CONDUCTING ACCEPTANCE TEST. • THE CENTRAL MONITORING STATION NAME, TELEPHONE NUMBER(S), ADDRESS AND ACCOUNT NUMBER FOR THE FACP SHALL BE LABELED BY MEANS OF A DURABLE PERMANENT METHOD WITHIN THE FACP. • THE NRTL LISTED CENTRAL MONITORING STATION COMPANY IS: NAME: NRTL LISTING NUMBER: ADDRESS: TELEPHONE: ALT TEL NO. DEVICES MANUAL PULL STATION • SHALL BE MOUNTED 48 INCHES ABOVE FINISHED FLOOR TO LEVER OF DEVICE. • SHALL BE READILY ACCESSIBLE AND CLEAR OF ANY OBSTRUCTIONS. • SHALL BE MOUNTED WITHIN FIVE FEET OF EXIT. • SHALL RELEASE ALL ELECTRIC DOOR LOCKS. • SHALL DISPLAY THE ALARM SIGNAL AT THE FACP AND REMOTE ANNUNCIATOR (IF APPLICABLE), ACTIVATE ALARM NOTIFICATION APPLIANCES AS REQUIRED AND INITIATE TRANSMISSION OF SIGNAL TO CENTRAL STATION FOR INITIATING CENTRAL STATION SERVICE RESPONSE IN ACCORDANCE WITH NFPA 70 - 2010 EDITION - CHAPTER 8/SECTION 8.2.7. SMOKE DETECTOR • SHALL BE LOCATED ABOVE ALL CONTROL EQUIPMENT. • SHALL BE LOCATED MINIMUM OF THREE FEET FROM HVAC VENTS. • SHALL RELEASE ALL ELCTRIC DOOR LOCKS. • SHALL DISPLAY THE ALARM SIGNAL AT THE FACP AND REMOTE ANNUNCIATOR (IF APPLICABLE), ACTIVATE ALARM NOTIFICATION APPLIANCES AS REQUIRED AND INITIATE TRANSMISSION OF SIGNAL.TO CENTRAL STATION FOR INITIATING CENTRAL STATION SERVICE RESPONSE IN ACCORDANCE WITH NFPA 72 - 2010 EDITION - CHAPTER 8/SECTION 8.2.7. DUCT SMOKE DETECTOR • SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72 - 2010 EDITION - CHAPTER 5/SECTIONS 5.7.4 AND 5.14. • SHALL SHUT DOWN THE HVAC UNIT, AND ALL OTHER HVAC UNITS SERVING THE SAME COMPARTMENT UPON DETECTOR ACTIVATION VIA AN APPROVED METHOD. NFPA 72 - 2010 EDITION - CHAPTER 5 / SECTION 5.14.4. • SHALL DISPLAY THE SUPERVISORY SIGNAL (WITH AHJ APPROVAL) AT THE FACP AND REMOTE ANNUNCIATOR (IF APPLICABLE), AND INITIATE TRANSMISSION OF SIGNAL TO CENTRAL STATION FOR INITIATING CENTRAL STATION SERVICE RESPONSE IN ACCORDANCE WITH NFPA 72 - 2007 EDITION - CHAPTER 8/SECTION 8.2.7. • REMOTE TEST STATIONS SHALL BE INSTALLED FOR EACH DUCT DETECTOR THAT IS NOT VISIBLE FROM THE FLOOR LEVEL OR ABOVE 10 FEET THE FINISHED FLOOR FOR THE PURPOSE OF IDENTIFYING DETECTORS THAT HAVE ACTIVATED, NFPA 2 - 2007 EDITION CHAPTER 5 / SECTION 5.14.5.8. • DUCT SMOKE DETECTORS ARE NOT LISTED LIFE -SAFETY DEVICES, PROPER SHUTDOWN MAY NOT BE POSSIBLE DUE TO IMPROPER MAINTENANCE AND ENVIRONMENTAL CONDITIONS. FIRE ALARM GENERAL NOTES (CONT.). DEVICES (CONT.) AUDIBLE VISUAL NOTIFICATION APPLIANCE MOUNTING • IF THE PLAN UTILIZES CEILING MOUNTED NOTIFICATION DEVICES THEY SHALL BE DONE SO IN ACCORDANCE WITH AHJ APPROVAL, NRTL LISTING REQUIREMENTS AND NFPA 72 - 2007 EDITION - CHAPTER 7 / SECTION 7.3.5. • VISUAL PATTERN COVERAGE AND SPACING BASED ON NFPA 72 - 2010 EDITION - CHAPTER 7 / SECTION 7.5. • VISIBLE NOTIFICATION APPLIANCES USED IN THE PUBLIC MODE MUST BE LOCATED AND MUST BE OF A TYPE, SIZE, INTENSITY, AND NUMBER SO THAT THE OPERATING EFFECT OF THE APPLIANCE IS SEEN BY THE INTENDED VIEWERS REGARDLESS OF THE VIEWER'S ORIENTATION, NFPA 70 - 2010 EDITION - CHAPTER 7 / SECTION 7.5.1(A). • VISUAL NOTIFICATION SHALL BE SYNCHRONIZED AND SHALL BE REQUIRED WHEN MORE THAN TWO VISUAL DEVICES ARE SEEN AT A 120 DEGREES FIELD OF VIEW, PER NFPA 72. • AUDIBLES SHALL GENERATE A THREE PULSE TEMPORAL PATTERN IN ACCORDANCE WITH ANSI AND NFPA 72 PRIOR TO VOICE ANNOUNCEMENT. DOOR RELEASE • MAGNETIC DOOR LOCKS SHALL RELEASE FIRE DOORS ON ALL FIRE ALARM CONDITIONS AND SIGNALS FROM THE FIRE ALARM CONTROL PANEL. • THE DOORS SHALL OPERATE IN ACCORDANCE WITH FLORIDA BUILDING CODE CHAPTER 10 1008.1.8.6. DOOR HOLDERS • MAGNETIC DOOR HOLDERS SHALL RELEASE FIRE DOORS ON ALL FIRE ALARM CONDITIONS AND SIGNALS FROM THE FIRE ALARM CONTROL PANEL. SIGNAGE • THE DEDICATED 120 VAC CIRCUIT SHALL BE PAINTED RED AND LABELED "FIRE ALARM CIRCUIT" AND PROVIDED WITH MECHANICAL PROTECTION WHEN NOT LOCATED WITHIN AN INACCESSIBLE SPACE BY THE GENERAL PUBLIC. • LOCATION OF TIE AC CIRCUIT BREAKER IS TO BE LABELED ON THE INTERIOR OF THE FACP DOOR, • BATTERY CALCULATION ` AY REFLECT MORE DEVICES FOR FUTURE ADDITIONS AND LABELLED 0 THE FACS DOOR. • BATTERIES ARE TO BE L<AStLtl) WITH TIME MONTH AND YEAR OF INSTALLATION. • BATTERIES ARE TO BE LABELED WITH THE DATE OF MANUFACTURE. • A FRAMED DURABLE SIGN ABOVE THE FACP INDICATING LOCATION OF THE TEST AND RECORD DOCUMENTS SHALL BE PROVIDED. • MINIMUM 8"x10" SIGN STATING "FACP INSIDE" SHALL BE PLACED ON DOORS THAT CONTAIN THE FACP. FIRE ALARM SYSTEM SEQUENCE OF OPERATION: AUTOMATIC RESPONSE FUNCTION SHALL BE INITIATED ONLY BY THE FIRST FIRE ALARM RECEIVED. ADDITIONAL ALARM SHALL BE RECEIVED, ANNUNCIATED AND SHALL INITIATE AUTOMATIC RESPONSE FUNCTIONS ASSOCIATED EXCLUSIVELY WITH SUBSEQUENT ALARM. THE ACTUATION OF THE FIRE ALARM INITIATING DEVICE SHALL AUTOMATICALLY INITIATE THE FUNCTIONS DETAILED BELOW: ALL FIRE ALARMS REPORT/RETRANSMIT SIGNAL TO FIRE DEPT. VIA CENTRAL STATION SERVICE. 1. ACTIVATION OF MANUAL FIRE ALARM STATIONS SHALL INITIATE THE FOLLOWING FUNCTIONS: A. INDICATE THE LOCATION OF THE DEVICE ON THE CONTROL PANEL AND ON THE REMOTE ANNUNCIATOR (IF APPLICABLE). B. CAUSE AN AUDIBLE SIGNAL AT THE CONTROL PANEL. (ALARM) C TRANSMIT AN AUDIBLE AND VISUAL ALARM SIGNAL TO FLOOR OF ACTIVATION, THE FLOOR ABOVE, THE FLOOR BELOW AND THE GROUND FLOOR. 2. ACTIVATION OF SMOKE DETECTORS OR HEAT DETECTORS SHALL INITIATE THE FOLLOWING: A. INDICATE THE LOCATION OF THE DEVICE ON THE CONTROL PANEL AND ON THE REMOTE ANNUNCIATOR (IF APPLICABLE). B. CAUSE AN AUDIBLE SIGNAL AT THE CONTROL PANEL (ALARM. C. TRANSMIT AN AUDIBLE AND VISUAL ALARM SIGNAL TO FLOOR OF ACTIVATION, THE FLOOR ABOVE, THE FLOOR BELOW AND THE GROUND FLOOR. 3. ACTIVATION OF SMOKE/HEAT DETECTORS (ELEVATOR), SHALL INDICATE THE FOLLOWING: A. INDICATE THE LOCATION OF THE DEVICE ON THE CONTROL PANEL. B. CAUSE AN AUDIBLE SIGNAL AT THE CONTROL PANEL (ALARM) C. INITIATE THE AUTOMATIC RECALL OPERATION OF ELEVATOR AS FOLLOWS: 1. RECALL ELEVATOR TO THE GROUND FLOOR UPON ACTIVATION OF ANY ELEVATORS ALARM INITIATING CIRCUIT ON ANY FLOOR OTHER THAN THE GROUND FLOOR. 2. RECALL ELEVATOR TO THE ALTERNATE LEVEL (1ST FLOOR) UPON ACTIVATION OF ELEVATOR ALARM CIRCUIT ON THE GROUND LEVEL. D. TRANSMIT AN AUDIBLE AND VISUAL ALARM SIGNAL TO FLOOR OF ACTIVATION, THE FLOOR ABOVE, THE FLOOR BELOW AND THE GROUND FLOOR. 3. ACTIVATION OF SMOKE DETECTOR IN THE ELEVATOR MACHINE/EQUIPMENT ROOM SHALL RETURN THE ELEVATOR CAR TO GROUND LEVEL AND ILLUMINATE THE ELEVATOR WARNING LIGHT. F. ACTIVATION OF HEAT DETECTOR IN THE ELEVATOR MACHINE ROOM/SHAFT SHALL INITIATE THE ELEVATOR SHUNT TRIP FUNCTION. TOTAL CURRENT Cl 0.091 A C2 1.937 A C3 0.065 A 6 Cl NON -ALARM CURRENT C2 ALARM CURRENT C3 SECONDARY ALARM CURRENT DEVICE QTY DRAW NON -ALARM QTY W DRAW ALARM QTY o, Q DRAW NON -ALARM 1. SYSTEM MODULES C) M � aUtn W00 NwW�v 5�w� U W HPF24S6 MAIN CIRCUIT BOARD 1 X 0.09100 0.09100 1 X 0.14500 0.14500 1 X 0.06500 0.06500 POWER SUPERVISION RELAY 0 X 0.02500 0 U U U 0 X 0.02500 N� 0 X 0.02500 O 2. NAC 1 w cop O C\2 SW75 8 X 0.00000 0.00000 8 X 0.15800 1.26400 8 X 0.00000 0.00000 P2W75 3 X 0.00000 0.00000 3 X 0.17600 0.52800 3 X 0.00000 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 NAC #1 TOTALS (MAX 3 AMPS) 0.00000 1.79200 0.00000 TOTAL NON -ALARM LOAD: 0.091 TOTAL ALARM LOAD: 1.937 TOTAL SECONDARY NON -ALARM LOAD: 0.065 6 O z 0 � W M M � E-+ o, Q N 1-4a W M U��o C) M � aUtn W00 NwW�v 5�w� U W � w E ozo OU H aQZO�Q Q � � w � W W � �"+ w W Hzuw� 0 U U U W W >H N� HaH� w v E -"q O Z w cop O C\2 6 z 0 � M M � o, Q N W M U��o C) M � aUtn W00 NwW�v 5�w� U W ozo OU aQZO�Q W UUcn �"+ w W Hzuw� 0 U U U W W >H hE"� HaH� w v W cn U F-1 M „~, REVISION NO. DATE DESCRIPTION FA=2 ISSUE DATE: KFS/MTW 9.24.15 ,.IRE ALARM PARTIAL 16/2 FPLP NOTIFICATION WIRE 1-1 1-2 1-3 Alt PLAN, 1/a*—l'—®" NORTH 1-4 1-5 1-6 1-7 1-8 1-9 1-10 1-11 PARTIAL FIRE ALARM RISER'o""" N.T.s. NORTH TO THE BOTTOM OF 80" A.F.F. OR HORNSTRO/ STROBE 6" BELOW CEILING L1 (WHICHEVER IS LOWER) T' tYT— II II II II II II II I II II II II II II PULL STATION L I 48" A.F.F.-- ADA .F.F. ADA HEIGHT REQUIREMENTS N.T.S. WIRE LEGEND DESIGNATION WIRE A 16/2 FPLP NOTIFICATION WIRE DEVICE LEGEND SYMBOL DEVICE NAC NEW NOTIFICATION POWER BOOSTER WALL MOUNTED STROBE ONLY UNIT WALL MOUNTED HORN/STROBE UNIT O E EXISITNG SMOKE DETECTOR r— O —I koW 0-4 0 0 M 0--i F U d o O ^' � w N N aH� ~ W � Q � � ri w��a W QUUU > u W N HaH� 0-4 UwU W co o 62 0-4 0 0 M 0--i U d o O ^' aH� Qaa0u Q W u ri w��a W QUUU > u W IH HaH� UwU M FIRE ALARM GENERAL NOTES: ABBREVIATIONS: AHJ - AUTHORITY HAVING JURISDICTION (FIRE DEPARTMENT) FACP - FIRE ALARM CONTROL PANEL FCPS - FIRE CONTROL POWER SUPPLY NFPA - NATIONAL FIRE PROTECTION ASSOCIATION NRTL - NATIONALLY RECOGNIZED TESTING LABORATORY (ETL, FM, UL) SCOPE OF WORK INSTALLATION OF A FIRE ALARM SYSTEM IN ACCORDANCE WITH NFPA 72, STATE, AND LOCALLY ADOPTED CODES AND ORDINANCES. APPLICABLE CODES BASIC CONSTRUCTION AND DESIGN REQUIREMENTS AND CODE COMPLIANCE. STATE CODE OF REGULATIONS THE INSTALLATION OF THE FIRE ALARM SYSTEM SHALL COMPLY WITH THE CURRENT STATE, COUNTY, LOCAL, MUNICIPAL AHJ ADOPTED CODES OR ORDINANCES THAT ARE IN WRITTEN FORM. FLORIDA BUILDING CODE AND FLORIDA FIRE PREY NTION CODE THE INSTALLATION OF THE FIRE ALARM EQUIPMENT SHALL BE IN ACCORDANCE WITH NFPA 1 - NFPA 72 - NFPA 101. ANY REQUIRED CORRECTIONS OR DISAPPROVALS SHALL BE IN WRITING WITH ADOPTED CODE, ORDINANCE OR OTHER REFERENCED LANGUAGE PER THE AHJ. • ALARM INSTALLER INFORMATION SHALL BE PROVIDED PRIOR TO START OF INSTALLATION OR WHEN CONTRACTED FOR INSTALLATION. • THE FIRE ALARM INSTALLER IN CHARGE OF THIS PROJECT SHALL BE CERTIFIED AND LICENSED BY THE STATE OF FLORIDA AND/OR LOCAL REQUIREMENTS. PROOF OF SUCH CERTIFICATION SHALL BE ON THE INSTALLER AT ALL TIMES AND SHALL BE PROVIDED UPON REQUEST BY THE AHJ. • INSTALLER IN CHARGE SHALL COORDINATE ALL WORK WITH THE OWNER/PROPERTY MANAGER AND ALL OTHER TRADES. • CONSULT WITH LOCAL AHJ, OWNER AND/OR OTHER TRADES FOR EXACT LOCATION OF THE FIRE CONTROL PANEL AND ALL DEVICES PRIOR TO INSTALLATION. • THE EQUIPMENT AND MATERIAL SHALL BE STATE OF FLORIDA FIRE MARSHAL LISTED AND APPROVED FOR USE AS SET FORTH BY NFPA 72 AND NRTL STANDARDS. • THE FIRE ALARM CONTRACTOR SERVICE, MAINTENANCE, TESTING AND MONITORING CONTRACTS SHALL BE SUBMITTED TO THE AHJ PRIOR TO CONDUCTING ACCEPTANCE TEST. • THE FIRE ALARM SERVICE, MAINTENANCE, TESTING AND MONITORING PROVIDER SHALL BE CENTRAL STATION SERVICE CERTIFIED BY A NRTL. PROOF OF CERTIFICATION SHALL BE SUBMITTED TO THE AHJ PRIOR TO CONDUCTING ACCEPTANCE TEST. SYSTEM INSTALLATION • THE STATE OF FLORIDA LICENSED ELECTRICAL CONTRACTOR SHALL PROVIDE A 120 VAC 15 OR 20 AMP DEDICATED CIRCUIT TO THE LOCATION OF THE FACP / FCPS AND OTHER PANELS REQUIRING PRIMARY POWER. • THE CIRCUIT SHALL BE MECHANICALLY PROTECTED WITH A LISTED -BREAKER LOCK -OUT DEVICE THAT MEETS OSHA 1910.147. (EXAMPLE DEVICE - MASTER LOCK 4938) EXCEPTION: BREAKER LOCATED WITHIN LOCKED CABINET OR ROOM THAT IS ACCESSIBLE TO AUTHORIZED PERSONNEL ONLY. • THE MULTIPLE PANEL ARRANGEMENT IN A SINGLE LOCATION SHALL REQUIRE JUNCTION BOXES FOR 120 VAC CIRCUIT SPLICES. MULTIPLE CONDUCTORS UNDER SINGLE TERMINALS OR WIRE SPLICED WITHIN CONTROL PANEL EQUIPMENT WILL NOT BE ALLOWED. • THE DEDICATED 120 VAC BRANCH CIRCUIT SHALL BE CLEARLY IDENTIFIED AND LABELED "FIRE ALARM CIRCUIT" IN RED. • LOCATION OF THE CIRCUIT BREAKER CONNECTED TO EACH CONTROL PANEL SHALL BE LABELED WITHIN EACH CONTROL PANEL. • POWER LIMITED WIRING SHALL BE SEPARATED FROM NON -POWER LIMITED WIRING AND CLASS 1 CIRCUITS A MINIMUM OF .25 INCHES OR AS INSTRUCTED BY THE CONTROL PANEL MANUFACTURER. • ALL CIRCUITS WILL BE IDENTIFIED AT JUNCTIONS AND AT TERMINATION BY MEANS OF A DURABLE PERMANENT AND VISIBLE LABEL. • ALL WIRING AND CABLING METHODS SHALL COMPLY WITH NATIONAL ELECTRIC CODE` 70 ARTICLE 760. • NO "T" TAPPING OF FIELD WIRINGS IS ALLOWED ON SUPERVISED CIRCUITS, EXCEPTION: SLC/DATA CIRCUITS PER MANUFACTURERS SPECIFICATIONS. RETRANSMISSION OF SIGNALS • THE FIRE ALARM SYSTEM SHALL BE EQUIPPED WITH TWO AHJ ACCEPTABLE, NRTL CENTRAL STATION LISTED MEANS OF TRANSMISSION OF ALL SIGNALS TO AN AHJ ACCEPTABLE, NRTL LISTED CENTRAL MONITORING STATION. • THE MEANS OF TRANSMISSIONS SHALL BE PROGRAMMED TO INITIATE AND COMPLETE A TEST SIGNAL EVERY 24 HOURS MINIMUM. EACH PATH CAN ALTERNATE 24 HOUR PERIODS AS LONG AS THE CENTRAL STATION RECEIVES A SIGNAL EVERY 24 HOURS. • A LOCAL TROUBLE SHALL SOUND AND BE LOCATED SUCH THAT IT CAN BE HEARD WITHIN OCCUPIABLE SPACE IF ONE OF THE MEANS OF TRANSMISSION IS COMPROMISED OR FAILS ON A SIGNAL TRANSMISSION ATTEMPT. • THE PROTECTED PROPERTY CONTACT LIST WITH NAMES AND CALL NUMBERS OF AT LEAT THREE INDIVIDUALS RESPONSIBLE FOR THE PROTECTED PROPERTY SHALL BE PROVIDED TO THE AHJ PRIOR TO CONDUCTING ACCEPTANCE TEST. • THE CENTRAL MONITORING STATION NAME, TELEPHONE NUMBER(S), ADDRESS AND ACCOUNT NUMBER FOR THE FACP SHALL BE LABELED BY MEANS OF A DURABLE PERMANENT METHOD WITHIN THE FACP. • THE NRTL LISTED CENTRAL MONITORING STATION COMPANY IS: NAME: NRTL LISTING NUMBER: _ ADDRESS: N TELEPHONE: ALT TEL NO. DEVICES MANUAL PULL STATION • SHALL BE MOUNTED 48 INCHES ABOVE FINISHED FLOOR TO LEVER OF DEVICE. • SHALL BE READILY ACCESSIBLE AND CLEAR OF ANY OBSTRUCTIONS. • SHALL BE MOUNTED WITHIN FIVE FEET OF EXIT. • SHALL RELEASE ALL ELECTRIC DOOR LOCKS. • SHALL DISPLAY THE ALARM SIGNAL AT THE FACP AND REMOTE ANNUNCIATOR (IF APPLICABLE), ACTIVATE ALARM NOTIFICATION APPLIANCES AS REQUIRED AND INITIATE TRANSMISSION OF SIGNAL TO CENTRAL STATION FOR INITIATING CENTRAL STATION SERVICE RESPONSE IN ACCORDANCE WITH NFPA 70 - 2010 EDITION - CHAPTER 8/SECTION 8.2.7. SMOKE DETECTOR • SHALL BE LOCATED ABOVE ALL CONTROL EQUIPMENT. • SHALL BE LOCATED MINIMUM OF THREE FEET FROM HVAC VENTS. • SHALL RELEASE ALL ELCTRIC DOOR LOCKS. • SHALL DISPLAY THE ALARM SIGNAL AT THE FACP AND REMOTE ANNUNCIATOR (IF APPLICABLE), ACTIVATE ALARM NOTIFICATION APPLIANCES AS REQUIRED AND INITIATE TRANSMISSION OF SIGNAL TO CENTRAL STATION FOR INITIATING CENTRAL STATION SERVICE RESPONSE IN ACCORDANCE WITH NFPA 72 - 2010 EDITION - CHAPTER 8/SECTION 8.2.7. DUCT SMOKE DETECTOR • SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72 - 2010 EDITION - CHAPTER 5/SECTIONS 5.7.4 AND 5.14. • SHALL SHUT DOWN THE HVAC UNIT, AND ALL OTHER HVAC UNITS SERVING THE SAME COMPARTMENT UPON DETECTOR ACTIVATION VIA AN APPROVED METHOD. NFPA 72 - 2010 EDITION - CHAPTER 5 / SECTION 5.14.4. • SHALL DISPLAY THE SUPERVISORY SIGNAL (WITH AHJ APPROVAL) AT THE FACP AND REMOTE ANNUNCIATOR (IF APPLICABLE), AND INITIATE TRANSMISSION OF SIGNAL TO CENTRAL STATION FOR INITIATING CENTRAL STATION SERVICE RESPONSE IN ACCORDANCE WITH NFPA 72 - 2007 EDITION - CHAPTER 8/SECTION 8.2.7. • REMOTE TEST STATIONS SHALL BE INSTALLED FOR EACH DUCT DETECTOR THAT IS NOT VISIBLE FROM THE FLOOR LEVEL OR ABOVE 10 FEET THE FINISHED FLOOR FOR THE PURPOSE OF IDENTIFYING DETECTORS THAT HAVE ACTIVATED, NFPA 2 - 2007 EDITION CHAPTER 5 / SECTION 5.14.5.8. • DUCT SMOKE DETECTORS ARE NOT LISTED LIFE -SAFETY DEVICES, PROPER SHUTDOWN MAY NOT BE POSSIBLE DUE TO IMPROPER MAINTENANCE AND ENVIRONMENTAL CONDITIONS. FIRE ALARM GENERAL NOTES iC0_ NT.) DEVICES (CONT.) AUDIBLE VISUAL NOTIFICATION APPLIANCE MOUNTING • IF THE PLAN UTILIZES CEILING MOUNTED NOTIFICATION DEVICES THEY SHALL BE DONE SO IN ACCORDANCE WITH AHJ APPROVAL, NRTL LISTING REQUIREMENTS AND NFPA 72 - 2007 EDITION - CHAPTER 7 / SECTION 7.3.5. • VISUAL PATTERN COVERAGE AND SPACING BASED ON NFPA 72 - 2010 EDITION - CHAPTER 7 / SECTION 7.5. • VISIBLE NOTIFICATION APPLIANCES USED IN THE PUBLIC MODE MUST BE LOCATED AND MUST BE OF A TYPE, SIZE, INTENSITY, AND NUMBER SO THAT THE OPERATING EFFECT OF THE APPLIANCE IS SEEN BY THE INTENDED VIEWERS REGARDLESS OF THE VIEWER'S ORIENTATION, NFPA 70 - 2010 EDITION - CHAPTER 7 / SECTION 7.5.1(A). • VISUAL NOTIFICATION SHALL BE SYNCHRONIZED AND SHALL BE REQUIRED WHEN MORE THAN TWO VISUAL DEVICES ARE SEEN AT A 120 DEGREES FIELD OF VIEW, PER NFPA 72. • AUDIBLES SHALL GENERATE A THREE PULSE TEMPORAL PATTERN IN ACCORDANCE WITH ANSI AND NFPA 72 PRIOR TO VOICE ANNOUNCEMENT. DOOR RELEASE • MAGNETIC DOOR LOCKS SHALL RELEASE FIRE DOORS ON ALL FIRE ALARM CONDITIONS AND SIGNALS FROM THE FIRE ALARM CONTROL PANEL. • THE DOORS SHALL OPERATE IN ACCORDANCE WITH FLORIDA BUILDING CODE CHAPTER 10 1008.1.8.6. _DOOR HOLDERS • MAGNETIC DOOR HOLDERS SHALL RELEASE FIRE DOORS ON ALL FIRE ALARM CONDITIONS AND SIGNALS FROM THE FIRE ALARM CONTROL PANEL. SIGNAGE • THE DEDICATED 120 VAC CIRCUIT SHALL BE PAINTED RED AND LABELED "FIRE ALARM CIRCUIT" AND PROVIDED WITH MECHANICAL PROTECTION WHEN NOT LOCATED WITHIN AN INACCESSIBLE SPACE BY THE GENERAL PUBLIC. • LOCATION OF THE AC CIRCUIT BREAKER IS TO BE LABELED ON THE INTERIOR OF THE FACP DOOR. • BATTERY CALCULATION MAY REFLECT MORE DEVICES FOR FUTURE ADDITIONS AND LABELED 0 THE FACP DOOR. • BATTERIES ARE TO BE LABELED WITH THE MONTH AND YEAR OF INSTALLATION. • BATTERIES ARE TO BE LABELED WITH THE DATE OF MANUFACTURE. • A FRAMED DURABLE SIGN ABOVE THE FACP INDICATING LOCATION OF THE TEST AND RECORD DOCUMENTS SHALL BE PROVIDED. • MINIMUM 8"x10" SIGN STATING "FACP INSIDE" SHALL BE PLACED ON DOORS THAT CONTAIN THE FACP. FIRE ALARM SYSTEM SEQUENCE OF OPERATION: AUTOMATIC RESPONSE FUNCTION SHALL BE INITIATED ONLY BY THE FIRST FIRE ALARM RECEIVED. ADDITIONAL ALARM SHALL BE RECEIVED, ANNUNCIATED AND SHALL INITIATE AUTOMATIC RESPONSE FUNCTIONS ASSOCIATED EXCLUSIVELY WITH SUBSEQUENT ALARM. THE ACTUATION OF THE FIRE ALARM INITIATING DEVICE SHALL AUTOMATICALLY INITIATE THE FUNCTIONS DETAILED IW: ALL FIRE ALARMS REPORT/kETRANSMIT SIGNAL TO FIRE DEPT. VIA CENTRAL STATION SERVICE. 1. ACTIVATION OF MANUAL FIRE ALARM STATIONS SHALL INITIATE THE FOLLOWING FUNCTIONS: A. INDICATE THE LOCATION OF THE DEVICE ON THE CONTROL PANEL AND ON THE REMOTE ANNUNCIATOR (IF APPLICABLE). B. CAUSE AN AUDIBLE SIGNAL AT THE CONTROL PANEL. (ALARM) C. TRANSMIT AN AUDIBLE AND VISUAL ALARM SIGNAL TO FLOOR OF ACTIVATION, THE FLOOR ABOVE, THE FLOOR BELOW AND THE GROUND FLOOR. 2. ACTIVATION OF SMOKE DETECTORS OR HEAT DETECTORS SHALL INITIATE THE FOLLOWING: A. INDICATE THE LOCATION OF THE DEVICE ON THE CONTROL PANEL AND ON THE REMOTE ANNUNCIATOR (IF APPLICABLE). B. CAUSE AN AUDIBLE SIGNAL AT THE CONTROL PANEL (ALARM. C. TRANSMIT AN AUDIBLE AND VISUAL ALARM SIGNAL TO FLOOR OF ACTIVATION, THE FLOOR ABOVE, THE FLOOR BELOW AND THE GROUND FLOOR. 3. ACTIVATION OF SMOKE/HEAT DETECTORS (ELEVATOR), SHALL INDICATE THE FOLLOWING: A. INDICATE THE LOCATION OF THE DEVICE ON THE CONTROL PANEL. B. CAUSE AN AUDIBLE SIGNAL AT THE CONTROL PANEL (ALARM) C. INITIATE THE AUTOMATIC RECALL OPERATION OF ELEVATOR AS FOLLOWS: 1. RECALL ELEVATOR TO THE GROUND FLOOR UPON ACTIVATION OF ANY ELEVATORS ALARM INITIATING CIRCUIT ON ANY FLOOR OTHER THAN THE GROUND FLOOR. 2. RECALL ELEVATOR TO THE ALTERNATE LEVEL (1ST FLOOR) UPON ACTIVATION OF ELEVATOR ALARM CIRCUIT ON THE GROUND LEVEL. D. TRANSMIT AN AUDIBLE AND VISUAL ALARM SIGNAL TO FLOOR OF ACTIVATION, THE FLOOR ABOVE, THE FLOOR BELOW AND THE GROUND FLOOR. 3. ACTIVATION OF SMOKE DETECTOR IN THE ELEVATOR MACHINE/EQUIPMENT ROOM SHALL RETURN THE ELEVATOR CAR TO GROUND LEVEL AND ILLUMINATE THE ELEVATOR WARNING LIGHT. F. ACTIVATION OF HEAT DETECTOR IN THE ELEVATOR MACHINE ROOM/SHAFT SHALL INITIATE THE ELEVATOR SHUNT TRIP FUNCTION. M TOTAL CURRENT Cl 0.091 A C2 1.937 A C3 0.065 A lC� H � 0 w M DEVICE 1. SYSTEM MODULES Cl NON -ALARM CURRENT QTY DRAW NON -ALARM C2 ALARM CURRENT QTY DRAW ALARM C3 SECONDARY ALARM CURRENT QTY DRAW NON -ALARM HPF24S6 MAIN CIRCUIT BOARD 1 X 0.09100 0.09100 1 X 0.14500 0.14500 1 X 0.06500 0.06500 POWER SUPERVISION RELAY 0 X 0.02500 � 0 X 0.02500 U w U uu 0 X 0.02500 Iii 2. NAC # 1 z a4 N� w�v� Uk'U z M w O O SW75 8 X 0.00000 0.00000 8 X 0.15800 1.26400 8 X 0.00000 0.00000 P2W75 3 X 0.00000 0.00000 3 X 0.17600 0.52800 3 X 0.00000 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 0 X 0.00000 NAC #1 TOTALS (MAX 3 AMPS) 0.00000 1.79200 0.00000 TOTAL NON -ALARM LOAD: 0.091 TOTAL ALARM LOAD: 1.937 TOTAL SECONDARY NON -ALARM LOAD: 0.065 M REVISION NO. DATEDESCRIPTION FA=2 ISSUE DATE: KFS/MTW 9.24.15 lC� H � 0 w M OQ v�. W � A w�Wxv� a ��w 0 E..4 co ., HW OQH A � U � U w U uu w w Iii z a4 N� w�v� Uk'U z M w O O REVISION NO. DATEDESCRIPTION FA=2 ISSUE DATE: KFS/MTW 9.24.15 H � 0 M N v�. W CC w�Wxv� 0 .-� 0 Z pd�OU w OQH UUP U w U uu w w Iii z a4 rk �✓ w�v� Uk'U z M REVISION NO. DATEDESCRIPTION FA=2 ISSUE DATE: KFS/MTW 9.24.15