Loading...
PERMIT DOCUMENTS A-I CONSULTING ENGINEERS, INC ROOF STRUCTURES CONSULTING UPLIFT TEST EXPERTS LAB.CERTIFICATION No.01-1224-5 4383 SW 70 CT 119 LA%H.FL 33155 TEL: 305-740-9550 sFAX: 305-740-9550 August 22, 2017 City of Boynton Beach Building and zoning Department 100 E. Boynton Beach Blvd. Boynton Beach, FL 33425 CONTRACT: Al Pro Service Corp. JOB SITE: 301 SE 12(11 Ave Boynton Beach, FL PERMIT No: 1700002287 INSPECTION REPORT After a visual inspection performed at the above referenced location, and photo provided by roofing contractor we hereby certify that: Flat Roof • Slope= 1/8" / 12 pitch/ 10 ft mean hr. 5/8" PLYWOOD DECK (renail (@ 6" field and 4" corner) Base Sheet= 1 Base #75 1 1/4 RS nails 5/8 tin cap, FIELD 9 OC @ LAP 2 ROWS @ 9 OC _ PERIMETER 6 OC @ LAP 4 ROWS @ 6 OC CONER 6 CC @ LAP 4 ROWS @ 6 CC 2 PLY IV Hop mop with 18" side lap . 1 Ply Mineral Surfaced Cap Sheet Hop mop'with 3" side lap and 6" end lap. Product used= G.A.F Material Corp NOA 13-1022.15 To the best of my knowledge, belief and professional opinion, it was found that the roof installation complies with the minimum requirements of the Florida Building 2014 Codes 5ta . Edition and approved Permit package. Please do not hesitate to contact my office if you have questions regarding this inspection. Sincerely, ,,,1, .,,,,,,'' P M4 r2'•. �Q ,- ' EN 9 q wF•, r , q No 31f.)0 • 5 = .Se A. a P;E:Lic. . c1 ;Oa ; Seal aIIok._ue rare . t t P. ' n^ ' n li t 0 .,�ti��' 1 F• `