PERMIT DOCUMENTS TROY-MOSES PANTON
Florida Architect AR94097
14311 Biscayne Blvd.#4323—Miami,FL 33161
786.985.9156 I www.troymoses.com I troymoses@gmail.com
July 28, 2017
City of Boynton Beach Building Department
Re: Mirabella Villa 12925 South Federal Hwy—Boynton Beach, FL 33435
Permit No. 1700000894
OPENING INSPECTIONS FOR 300 VILLA CIRCLE—BUILDING NO.3
This letter serves to notify that my representative or I have inspected the installation every exterior
window and sliding glass door for the above referenced project and confirm that the new window and
door products have been installed as per the manufacturer's specifications and installation details.
To the best of my knowledge all work was done in compliance with the 2014 FBC and all applicable local
codes.
The product approvals are as follows:
Horizontal Sliding Window: CGI Windows & Doors, NOA# 15-0929.13 Series "Sentinel 120"
Single Hung: CGI Windows & Doors, NOA#15-0512.10 Series "Sentinel 110"
Sliding Glass Door: CGI Windows & Doors, NOA# 15-0619.06 Series "Sentinel 150"
New windows and sliding glass doors were properly sealed against water infiltration with Sikaflex
sealant on the exterior, and Loctite Polyseamseal on the interior per manufacturer specifications.
2nd and 3rd floor windows with sills less than 36" high are equipped with ASTM F 2090-10 approved
window opening control devices not to allow the passage of a 4" sphere.
Please feel free to contact project manager, Carlos De Los Santos, via email at cdls0l@gmail.com or
phone at 954.446.3810 if there are any further questions or concerns.
Respectfully yours,
Troy-Moses Panton, RA
C ?AN r.O doe.
1 '.
lig, . ' . •r
Yc •y0 .•;:c)
email:file of ,
C fk/ (
TROY-MOSES PANTON FILE Cop
Florida Architect AR94097
14311 Biscayne Blvd.#4323—Miami,FL 33161
786.985.9156 I www.troymoses.com I troymoses@gmail.com
August 21, 2017
City of Boynton Beach Building Department
Re: Mirabella Villa 12925 South Federal Hwy—Boynton Beach,FL 33435
This letter serves to notify that my representative or I have inspected the installation every exterior
window and sliding glass door for the permits listed below
Permit No. 1700000890(Mirabella Villa Bldg.#01)
Permit No.1700000899(Mirabella Villa Bldg.#02)
Permit No. 1700000894(Mirabella Villa Bldg.#03)
Permit No. 1700000900(Mirabella Villa Bldg.#04)
Permit No. 1700000892(Mirabella Villa Bldg.#05)
Permit No.1700000893(Mirabella Villa Bldg.#06)
Permit No. 1700000895(Mirabella Villa Bldg.#07)
Permit No. 1700000901(Mirabella Villa Bldg.#08)
Permit No.1700000897(Mirabella Villa Bldg.#10)-
Permit No. 1700000902(Mirabella Villa Bldg.#11)
Permit No.1700000891(Mirabella Villa Bldg.#12)
Permit No. 1700000898(Mirabella Villa Bldg.#13)
Please feel free to contact project manager, Carlos De Los Santos,via email at cdls0l@email.com or
phone at 954.446.3810 if there are any further questions or concerns.
Respectfully yours,
Troy-Moses Panton, RA
,• . ,
.. :...:
•t +. * ,
r * ' � 'ice�
email:file •• t ���
it °4%
LOG Mirabella Villa
2925 S. Federal Hwy
_ 300 Villa Circle Boynton Beach
°t �c
BuildingINSPECTION# 03
,, 4,T° N O
Permit # 1700000894
UNIT# Date: Passed Failed Comments Inspector
301 0510‘,/ 7 f" _ pewFrA/C &1" Bac -
302 0s4e% 7 ✓ _ Psis
303 ac/s1' eI1s_
304 0 s-At/, 7 c7.4s
305 05-A, /, , ✓ _ e/CS
306 0f-/;, % 7 / — gots
307 01-4e, 1 1 Y.
ea!<,
308 05- 44, /, 7 /9" tut
309 05-46, /7 ,--- eels
310 o;/4, /, 7 ✓ crvts
311 ,If5/4a/7 ✓ Ca-&S
312 05--",„/7 -�- _ 0.41c
313 0,--4,„ / _ &Bs
314 054/, _-- _ ams
315 e /0/, 7 _y — ems
316 s--/,,,4, _� — eats
317 os/oc / 7 _, �xs
318 o r /, , �- L__ v
sf-
3194 03 ,/,7 �.. — n ��E FLOq/U� �_ C'/YS
320 0s1a 9�, 7 A` ,, "�tio.�• ;° S,�s
321 044,77 7 ,.9 _ `,. ,Coek _s
322 os-bot !/ . o�Y - Ns; V r. LkS
323 0 s 104, 17 / ; a, v1/4."-- acs
324 as- A, /, , ✓ (1 (6 errs
� i FIFE COPY
r
`,l, CITY OF BOYNTON BEACH
UP •
\e `' u DEVELOPMENT DEPARTMENT I BUILDING DIVISION
' or3 �4•" 100 East Boynton Beach Boulevard•Boynton Beech,FL33425•(561)742-6350•Fax 742-6357
Special Inspector Application
In accordance with Section 110 of the Oty of the Boynton Beach Amendments to the Florida Building Code the request for a Special Structural
Inspector,a Florida Registered Architect or Licensed Engineer,to perform the following mandatory or discretionary inspections, as outlined In
Section 110 of the Florida Building Code. The Special/Threshold Inspector shall maintain progress Inspection reports onsite during
construction, submit to the Jurisdiction on a weekly basis Inspections reports, and provide a Certificate of Compliance after
a l I work Is complete to the Building Official before the final Inspection as per Section 110 of the Florida BuildingCode.
Note: The Building Official shall determine which discretionary inspections are to be delegated.
Name of Project:/1,A l f li V/14,44" Permit N_ Date: Steil 1_ .f 7
Project Address: `. t rimes i41._ OW? 21p Code:
Legal Description: PCN:09-43.45-= - -
A. Mandatory inspections Type:
1) Stem wall,monolithic slab on grade,footings/grade beams,pilings and pile caps. — :;.YY:E15.15513.4111:1:p"NNp40°°°:.
. O-
2) Lintel,tie beams,columns,masonry units,reinforcing steel and shoring. YNO
3) Structural Steel,connections,welding,bolts and anchor rods. YONO
4) Smoke Control Systems. YNO
5) Threshold Building(f.s.section 553.79(5)) YONO
B.Dlsaetlonary inspection Type:Per Building OBldal
1) Buildings and structures of unusual design or methods of construction. NO
• Windows and doorsNO
• Structural and fire resistance Integrity' • ES ONO
2) Buildings of Type I construction. ES ONO
3) Major structural alterations, OYES ONO
4) Where the concrete design is based on compressive strength in excess of 3,000 pounds per square inch. ES ONO
5) Buildings with an area greater than 20,000 square feet. OYES ONO
6) For buildings more than 2 stories in height. ES ONO
7) Pile driving. ES ONO
8) Private Provider, 4tructural ❑Electrical OPiumbing (]Mechanical ES ONO
9) Other. O
C. Mandatory Documentation:
1) Inspection schedule stating the specific inspection that will be made and at what phase of construction must be submitted plication.
2) Progress report/inspection reports during construction.
it
3) Certificate of Compliance shall b submitted priorrito the cheduling of the final building inspection
— Owners Printed name: c 4 rrSignature:
Permit Holders Primed Name: Signature: O• QN3 . •
Permit Holders License a: n < .4.
Ro _I N ti� jt/ O,•W f," L , • `
y '
Special Building inspector Printed Name: • tore: lyr� d+�
#.21Reglsleretl Architect and/or titan r.•ar�.�.r f. •.. . spt�g ‘
Special Inspector Signature: "'/► - Y�'. .' '�,�' �' ` Ls'
Spedal Inspector Address: L �.,�si iv •. s#�,y-3 . 3 b1 srl • �/ • V`
State of.s Floridalo� Registration
4: S` a
Phoney�e/-1.160 _Email: ?4( {/tiOte-Tr? eptA
inalseaVSrgggl�tih�Date
*Plans for all buildings shall indicate how required structural and fire resistance integrity will be maintained where a penetration of a
required fire resistant wall,floor or partition will be made for electrical,gas,mechanical,plumbing and communication conduits,
pipes and systems. Such plans shall also indicate in sufficient detail how the fire integrity will be maintained where required fire
resistant floors intersect the exterior walls and where joints occur in required fire resistant construction assemblies.
C:1Users\KltiendortS\Documents12010 Special Inspector Applicallon.docx