Loading...
PERMIT DOCUMENTS TROY-MOSES PANTON Florida Architect AR94097 • 14311 Biscayne Blvd.#4323—Miami,FL 33161 786.985.9156 I www.troymoses.com I troymoses@gmail.com July 28, 2017 City of Boynton Beach Building Department Re: Mirabella Villa 12925 South Federal Hwy—Boynton Beach, FL 33435 Permit No. 1700000899 OPENING INSPECTIONS FOR 200 VILLA CIRCLE—BUILDING NO. 2 This letter serves to notify that my representative or I have inspected the installation every exterior window and sliding glass door for the above referenced project and confirm that the new window and door products have been installed as per the manufacturer's specifications and installation details. To the best of my knowledge all work was done in compliance with the 2014 FBC and all applicable local codes. The product approvals are as follows: Horizontal Sliding Window: CGI Windows & Doors, NOA# 15-0929.13 Series "Sentinel 120" Single Hung: CGI Windows& Doors, NOA# 15-0512.10 Series "Sentinel 110" Sliding Glass Door: CGI Windows & Doors, NOA# 15-0619.06 Series "Sentinel 150" New windows and sliding glass doors were properly sealed against water infiltration with Sikaflex sealant on the exterior, and Loctite Polyseamseal on the interior per manufacturer specifications. 2nd and 3rd floor windows with sills less than 36" high are equipped with ASTM F 2090-10 approved window opening control devices not to allow the passage of a 4" sphere. Please feel free to contact project manager, Carlos De Los Santos, via email at cdls0l@email.com or phone at 954.446.3810 if there are any further questions or concerns. Respectfully yours, Troy-Moses Panton, RA 10-k ::::-C1::::11r1:::::::/: ' �.0 goTf f fC/. email:file ' ( oSw TROY-MOSES PANTON FILE �1I'Ao� Florida Architect AR94097 y 14311 Biscayne Blvd.#4323—Miami,FL 33161 786.985.9156 I www.troymoses.com I troymoses@gmail.com August 21, 2017 City of Boynton Beach Building Department Re: Mirabella Villa 12925 South Federal Hwy—Boynton Beach,FL 33435 This letter serves to notify that my representative or I have inspected the installation every exterior window and sliding glass door for the permits listed below Permit No. 1700000890(Mirabella Villa Bldg.#01) Permit No.1700000899(Mirabella Villa Bldg.#02) Permit No.1700000894(Mirabella Villa Bldg.#03). Permit No.1700000900(Mirabella Villa Bldg.#04) Permit No. 1700000892(Mirabella Villa Bldg.#05) Permit No. 1700000893(Mirabella Villa Bldg.#06)- Permit No.1700000895(Mirabella Villa Bldg.#07) Permit No. 1700000901(Mlrabella Villa Bldg.#08) Permit No.1700000897(Mirabella Villa Bldg.#10) Permit No.1700000902(Mirabella Villa Bldg.#11) Permit No. 1700000891(Mirabella Villa Bldg.#12) Permit No.1700000898(Mirabella Villa Bldg.#13) Please feel free to contact project manager, Carlos De Los Santos,via email at cdis01@gmail.com or phone at 954.446.3810 if there are any further questions or concerns. Respectfully yours, Troy-Moses Panton, RA • PNO•A"T; 1Ji N' •,• r , * :; : :� : T• ,tF FILE COPY I I(` • CITY OF BOYNTON BEACH nt �� .p - = • "., DEVELOPMENT DEPARTMENT I BUILDING DIVISION . v ` 4/ rrs ry 0 . 100 East Boynton Beach Boulevard•Boynton Beach,FL 37425•(561)742.6350•Fax 742-6357 Special Inspector Application In accordance with Section 110 of the Oty of the Boynton Beach Amendments to the Florida Building Code the request for a Special Structural Inspector,a Florida Registered Architect or Licensed Engineer,to perform the following mandatory or discretionary Inspections, as outlined In Section 110 of the Florida Building Code, The Special/Threshold Inspector shall maintain progress Inspection reports onsite during construction, submit to the Jurisdiction on a weekly basis Inspections reports, and provide a Certificate of Compliance after aII work Is complete to the Building Official before the final Inspection as per Section 110 of the Florida Building Code. Note: The Building Official shall determine whichcdiscretionary Inspections are to be delegated. Name of Project:67,41/ i' / tiILLr�A�" . Permit k= Date: (1/V./las Project Address: ?� c� ' ase C tFLW/ Zip Code: Legal Description: PCN:OB-43-45-= A. Mandatory Inspections Type: 1) Stern wall,monolithic slab on grade,footings/grade beams,pilings and pile caps. — OYES.ONO- 2) Lintel,tie beams,columns,masonry units,reinforcing steel and shoring. OYES ONO 3) Structural Steel,connections,welding,bolts and anchor rods. DYES ONO 4) Smoke Control Systems. DYES ONO 5) Threshold Building(f.s.section 553.79(5)) OYES ONO B.Discretionary Inspection Type:Per Building Offidal 1) Buildings and structures of unusual design or methods of construction. ❑ ES ONO • Windows and doors 27ES ONO • Structural and fire resistance integrity - DYES ONO 2) Buildings of Type I construction. DYES ONO 3) Major structulal alterations, - OYES ONO 4) Where the concrete design is based on compressive strength in excess of 3,000 pounds per square Inch. DYES ONO 5) Buildings with an area greater than 20,000 square feet. OYES ONO 6) For buildings more than 2 stories in height. OYES ONO 7) Pile driving. OYES ONO 8) Private Provider, Siftructural DElectrical OPlumbina DMedlanical OYES ONO 9) Other OYES ONO C. Mandatory Documentation: 1) inspection schedule stating the specific inspection that will be made and at what phase of construction must be submitted with this application. 2) Progress report/Inspection reports during construction. 3) Certificate of Compliance shall b submitted prior to the cheduling of the final building Inspection //,ves de/76-, V// f •,cs — Owners Printed name: /s'/c/ ,a, Signature: ,poi•,,,TO t, Permit Holders Printed Name: Signature: �1.''Q� Permit Holders License a: Lt:om:'�i•y :_t` �' —71-5;71-71.10'es' FlinmAI t :co01 CU ,,:.,+, • t . .. Special Building inspector Printed Name: lure: :• j�� - •CC �, registered Architect and/or 0 lken %. Special Inspector Signature: "/� - �i Y'•• ,W.i' rte. 4.t` Special Inspector Address: �r ri iv ;cub-If 4y�y -3.e), Dl / ; V 1 Slate of Florida RRS.tratl�ann It a Original SNl/S�Ifgt 1M7 D•O Phoney�C/-J_77�FSY __Email: 7J)( =��4��c. �t f QR "Plans for all buildings shall indicate how required structural and fire resistance integrity will be maintained where a penetration of a required fire resistant wall,floor or partition will be made for electrical,gas,mechanical,plumbing and communication conduits, pipes and systems.Such plans shall also indicate in sufficient detail how the fire integrity will be maintained where required fire resistant floors intersect the exterior walls and where joints occur in required fire resistant construction assemblies. C:tUsers1KillendorfS\Dowmente1201a Special inspector Applicatlon.docx G,TY. � INSPECTION LOG Mirabella Villa \ 2925 5. Federal Hwy o / u 200 Villa Circle Boynton Beach Building # 02 Ton o� Permit # 1700000899 UNIT# Date: Passed Failed Comments Inspector 201 „,,h,„L ., v _ as 202 oLi/a'' .7 - eJs 203 (min/7 V as 204 0v/jei/7 1 ' r s- 205 o'f/dq h1., — e&c 206 ny/2y/i7 I. _ ats 207 17 y/11/,7 — tis 208 o,/A?/' 7 v' — els 209 ov/29/7 t7 _ C 210 oei/ic/i/ aa 211 0s, 9/,1 05- 212 n5/Ug/, 7 ✓ ' egg 213 o.//Jq/, 7 �' _ 44. 214 0,1241, i �% _ eik 215 ' c,,,72 Q/, �'7 cats 216 oLP lzc/, i cats 217 o /A/ 7 v' C:'h3 218 inib q/ , ,/ (41<7 219 a,, /9/,/ v' F , . G'df� 220 n Y'l a q/./ ,..K" '�OO K. p'"v 05 221 �,. .a :� o t,'/xQ/7 i - ;,j ! o. ,c k 222 :o ice` .7 . • U i �:/ c/ _ ,t .it lii 223 o y Zit /, i� . '•`T; cr2?! 224 - o9/39 // 7 4./ r C,� ,